THE CONNECTED IRRIGATION EXPERT
LR-IS-FL
                              QUICK
                       INSTALLATION
                              GUIDE
PRESENTATION
The LR-IS-FL is a Bluetooth® / LoRaTM mains water timer, remotely controllable
from 2, 4, 6, 9 or 12 stations. Its probe input allows the connection to a rain
sensor or a flow meter / water meter.
The LR-IS-FL requires the association with a LR-MB (relay WiFi/LoRa)
or an LR-BST. (However it can be used in bluetooth)
Step 1
DOWNLOADING
1. On your smartphone and/or tablet, go to «App Store» ou «Google Play».
2. Search «MySOLEM» in the search bar.
     MySOLEM
3. Download MySOLEM application.
               GET         INSTALL
4. Once installed, activate the Bluetooth® on your smartphone a n d /or tablet.
CREATE UN ACCOUNT
To benefit from all LR-IS-FL features, please create a MySOLEM account.
1. Launch MySOLEM app from your smartphone a n d /or tablet.
2. Go to «My account» by typing on      icon.
3. Follow the steps described on the app.
                                       2
Step 2
PAIRING
1. Remove the lower hatch to let appear the terminal.
2. Connect the 220/24 Vac power supply and replace the hatch.
3. Launch the MySOLEM app.
4. Tap on the «Add a module» buton or the «+» buton .
5. Choose the LR-IS-FL from the list of nearby controllers.
6. (Optional) Define a name and a security key for your controller and click
on the button «Validate».
7. To finish the pairing of your LR-IS-FL, follow the next steps described
   in the app.
Note : To identify your LR-IS-FL among the nearby controllers, please refer
to the «Default name» present on his product label.
Security key
The security key allows to protect your controller. You can define it during the
step 6 of the «ASSOCIATION» or access to further information by clicking on
the icon       at the top right of your screen..
                                        3
Step 3
LR-MB PAIRING
To optimize the LoRaTM radio connection between the LR-MB and the LR-IS-FL
controllers, we advise to install the LR-IS-FL in a plastic valve box under 800
meters to the LR-MB. We also advise to associate all your LR-IS-FL near the
LR-MB before installing them separately in the valve boxes.
1. Select the LR-IS-FL programmer previously installed.
2. Click on the top right icon     to access to the product’s informations.
3. Click on «Remote Access».
4. Select the LR-MB you want to use.
5. Click on the button «Send» or        on the bottom of your screen to validate.
Once the pairing finished, you can test the connection between
your LR-MB and your LR-IS-FL :
6. Go back to «Remote access» screen.
7. Click on the button      to start the test.
Note :
- The message «Connection established» means that the connection is
reliable.
- The message «No connection established» means that it is necessary to
bring the LR-IS-FL closer to the LR-MB or vice versa.
                                         4
LR-BST PAIRING
1. On the application, select your LR-BST, and enter pairing mode        .
2. Select the LR-IS-FL programmer previously installed.
3. Tap the icon       at the top right of your screen to access product’s infor-
mation.
4. Tap on «Accés à distance».
5. Select in the list the LR-BST initially chosen.
Once the association is complete, you can test the connection between your
LR-BST and your LR-IS-FL
6. Return to the LR-IS-FL screen «Remote Access», previously seen.
7. Click on the button          to start the test.
Step 4
WIRING
Connect the LR-IS-FL to the solenoids as described below.
Use 24V valves only.
                    24V - S+ C C P 1 2 3 4 5 6 7 8 9 101112C
  24V
                                                   5
Step 5
SET SENSOR
      Warning, by default there are no sensor configured.
The LR-IS-FL has a - S + sensor input on which you can connect a rain sensor
or a pulse sensor / water meter after cutting the blue wire. Once the sensor is
connected, it is necessary to configure it in the application.
1. Using the MySOLEM mobile app, connect to your LR-IS-FL.
2. Click on Add Sensor.
3. Select your sensor type and follow the instructions given by the application
Step 6
SET FLOWMETER
1. Check the «Instant Value».
Instant Value: Ensures that the volume consumed indicated on the water
meter is the same as the volume displayed on the application. If a gap is
noted, check the wiring (polarity) or adjust the «COEFFICIENT» value.
2. Fill in the remaining fields.
High threshold (daily volume): maximum consumption (in liter) that you
do not want to exceed in a period of 24h. If the goal is exceeded you will be
alerted immediately (by e-mail and notification smartphone and / or tablet).
Low threshold (daily volume): minimum consumption (in liters) that you
want to achieve over a period of 24h. If the goal is not reached you will be
alerted the next day at 7am (by e-mail and notification smartphone and / or
tablet).
Leak alert volume: water volume threshold (in liter) from which you want to
be alerted.
                                       6
Station flow: for each station, read the flowmeter at time T (Cpt1), then at
time T + 5mn (Cpt2).
Make the calculation (Cpt2 - Cpt1) / 5 => Flow (L / min)
In the application fill in the results.
High Threshold (Station Flow Alerts): Maximum consumption warning
threshold in % of the calibrated flow of the channel. The «High threshold»
alert is immediate as soon as it is reached.
Low threshold (Station Flow Alerts): Minimum consumption warning
threshold in % of the calibrated flow of the channel. The «High threshold»
alert is immediate as soon as it is reached. For each station flow alert you have
the possibility to define the desired type of action:
      • No action: watering continues.
      • Permanent OFF: resuming watering requires a manual ON command (in
the application on the programmer concerned).
      • Inhibit the output: stops the station concerned, requires the
acknowledgment of the alert (in the application on the programmer
concerned) to reactivate the station.
Stabilization time:
Time required before the water flow is stable when starting and stopping the
station. It eliminates the peak flow (start) or leak (stop). The time is the same
for all stations.
During this period, the consumption is not taken into account for triggering
alerts or actions.
                                         7
                         24V - S+ C C P 1 2 3 4 5 6 7 8 9 101112C
            24V
   L/mn
 Flowmeter,
 water meter
Connect your + S - input to a water meter equipped with a flow sensor as
shown above. Use dry contact flow sensors or equivalent.
For polarized flow sensors, when wiring,observe the polarization :
                       Red wire -> + Black wire - > -
                                              8
INFORMATION ON THE STATUS OF THE LED
Green LED : normal operation
Blinking green LED : One channel is in progress (the flashing number
corresponds to the station number activated).
Green LED and Red Flashing : One channel is in progress and the rain sensor
is activated or a station is in progress and the product is in permanent OFF or
several days.
LED Red Fixed : the product is in initialization mode
LED Red Flashing 2 times : The programmer has lost time, reconnect to re-
synchronize.
LED Red Flashing 4 times : One of the stations has a short circuit or is
overconsumption. The other reason is that you probably have powered down
2 times in a short time while a station is still in progress.
LED Red Flashing 5 times : You have exceeded the time required to initialize
the timer. Repeat the initialization procedure.
LED Off : The product is not powered.
                                        9
FAQ
What are the features required for the Bluetooth® product to work?
Android 4.3 (or more) Smartphones or tablets equipped with Bluetooth Smart
4.0 (or more). iOS 9.0 Apple iPhone or iPad running (or more) with Bluetooth
Smart 4.0 (or more)
Why does my station not start?
It has to be assigned a time and a Program A, B or C to each station. If several
stations are assigned to the same program, they will start one after the other.
Why does Program B not start? If Program A departure time is the same than
Program B’s one, then the programs will be executed one after the other.
What is output P for?
You can connect a master valve or a pump through a relay, on P output. It will
start automatically 2 sec before each station and during each station watering.
What are the controller’s output S (blue wire) for? You can plug a rain sensor
into S outputs, to do that you need to cut the blue wire.
How does the rain sensor work? When connected to the yellow wire the rain
sensor acts on the 3 programs. If it is raining, programs A, B and C won’t start;
you must wait the probe to dry before the programs star again. The manual
control “All stations” is not affected by the rain sensor conditions.
What is the Water Budget? The Water Budget allows to add a time percentage,
according to the time recorded by each station. It is generally used during
seasonal changes (for example: summer to autumn, or spring to summer).
E.g.: If you entered Station 1 = 1h on Program A and Station 2 = 0h30 on
Program A. Then, if you enter a Water Budget for Program A at 120%, when
starting Program A, stations 1 and 2 will be increased by 20%, which means
1h12 for Station 1 and 0h36 for Station 2.
How can I restart the pairing or the pairing procedure?
To start the pairing procedure again, just bypass the 2 pins of the battery
pressure (battery prior removed) for 30s minimum.
                                       10
If my device has no more battery, do I lose my programs?
No, they are not lost, they are automatically saved.
I would like to reset the settings of my device. How do I do it?
Open the app, go to the product, then open the        Settings and select
«Erase programs and durations».
GENERAL INFORMATIONS
READ THE FOLLOWING SAFETY INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR USING THE LR-IS-FL. BE SURE TO CAREFULLY OBSERVE
EMPLOYMENT PRECAUTIONS.
The LR-IS-FL must be installed indoor or under cover.
Install your product so that the socket outlet is near the equipment. The
socket is a disconnecting device, in case of problems, it must be easily
accessible at all times. Make sure the power outlet to which your power
transformer is connected has overcurrent and circuit breaker type 16A
protection. Use only the power supply unit supplied with the product:
INPUT : 230V ~ 50Hz OUTPUT : 24V ~ 0.75A
                                                            TM
          This symbol indicates that the product uses a LoRa technology radio.
          This symbol indicates that the product uses a Bluetooth®technology radio.
          The symbol «CE» indicates that this device complies with the European standards on
          safety, health, environment and user protection. Devices with the symbol «CE» are
          intended for sale in Europe.
          This symbol indicates that these types of electrical and electronic equipment must
          be disposed of separately in European countries. Do not dispose of this device with
          your household waste. Please use the collection and recycling points available in your
          country when you no longer need this device.
                                               11
~   This symbol indicates that the supply voltage is an AC voltage.
    This symbol indicates that the power supply is intended for indoor use only.
    This symbol indicates that the power supply unit has a double insulation class 2.
    This symbol indicates that the power supply unit has a thermal protection of 130 ° C.
                                            12
TECHNICAL FEATURES
DIMENSIONS
Version 2,4,6 Stations: Width 11 cm x Height 14,3 cm x Depth 4,2 cm
Version 9, 12 Stations: Width 16 cm x Height 14,3 cm x Depth 4,2 cm
INSTALLATION
Rain sensor or Water meter connection
Master valve connection
24V valves solenoid compatible
Maximum wiring length with solenoids: 30 m
Ambient temperature of product use : -20°C à 60°C
ALIMENTATION
Power INPUT : 230V ~ 50Hz / OUTPUT : 24V ~ 0.75A 50Hz
FEATURES
Bluetooth® Smart 4.0 Low Energy [2400-2483.5]Mhz
LoRaTM radio communication
Permanent programming save
Internal clock saved in case of power failure < 30 s
                                      13                              V160920