AFTER COOLER INSPECTION REPORT
Job No. : Eng. Model : CUMMINS QSK 60 DM
Customer : PT.TRITON GLOBAL MARITIM ESN : 33174483
CPL : 8452 Date : May. 13 2023
OEM : AE#3 Application : Diesel Generator
NOTE VISUAL INSPECTION
C core 01 visual check
H housing 02 blocked & cloged
03 pitting on core
04 leakage on core
05 crack on core
06 abrasive particles in core
PRESSURE TEST
specification : 65 PSI
INSPECTION DATA
AFTER CHECKED PARTS PRESSURE
REMARK
COOLER C H TEST RESULT
1 V V NL Componnent Reuse Again
2 V V NL
3 V V NL
4 V V NL
* fill "checked parts" with √ for serviceable, x for unserviceable
* fill "pressure test result" with NL for no leakage L for leakage
comment:
Reported By, Checked By, Acknowledge by
Adit
Mechanic CHIP ENGINEER OWNER
date : 13 May 2023 date : date :