Virgo Virgo

Patient Monitor
Patient Monitor

12.1”color TFT LCD screen,wide and flat screen design,ecnomic and reliable

Configuration . .
.
Various mounting solutions
.
12.1”color TFT LCD screen( touchscreen is optional )
Wired/Wireless CMS, support HL7 protocol to HIS
. .
8 waveform display,up to 12-lead ECG analysis
ECG+SpO2+NIBP+2TEMP+PR+RESP, Li-ion battery
SpO2 pulse-tone modulation (Pitch Tone)
. .
Powerful calculation(Hemodynamic,Dose,Oxygenation,Ventilation)

. .
MEWS(Modified Early Warning Score)
Optional Pacemaker detection

.
Graphical & tabular trend review( 240 hours), USB data output
.
ST & arrhythmia analysis(17 types)
Masimo SpO2, Suntech NIBP, IBP, CO2, Thermal recorder, Touch screen, CMS
SpO2 support PI,low perfusion 0.2% Rechargeable Lithium-Ion Battery
Night mode, standby mode, venipucture mode 48 Hours full disclosure waveforms review & print for each patient

Specifications

Physical Specification RESP Masimo SET® SpO2(Optional)


Display Measurement method : Thoracic electrical bioimpedance Measurement range : 0-100%
12.1”TFT LCD screen Operation modes: Auto/Manual Resolution: 1%
Resolution: 800 x 600 (1024 x 768 optional) Measuring lead: Lead I, II Accuracy: ±2%(70-100%,Adult/Pediatric,non-motion,
Number of traces: 8, up to 12 ECG waveforms Measurement range: Adult:0~120 bmp; low perfusion);
Neonate/Pediatric:0~150bpm ±3%(70-100%,Neonate,non-motion);
Dimension: 310×292×174mm(W×H×D)
Resolution: 1 bpm ±3%(70-100%,motion);
Weight: < 4 kg under standard configuration Apnea alarm delay:10s,15s,20s,25s,30s,35s,40s 0-69%,unspecified
7-lead ECG LAN: 1 standard RJ45 port Apnea alarm: Selectable Refreshing Rate: 1s
WLAN:IEEE 802.11b/g/n Wave gain: ×0.25, ×0.5, ×1, ×2
USB: 2 USB connectors Respiratory impedance range: 0.5-5Ω Mainstream CO2(Optional)
Baseline impedance: 500-4000Ω Measurement range: 0-19.7%,150mmHg, or 0-20kPa
ECG Gain: 10 grades Resolution: 0.1mmHg
Scan speed: 3.125mm/s, 6.25mm/s, 12.5 mm/s, 25mm/s Measurement accuracy
Lead type :3-lead,5-lead,12-lead(optional)
ECG waveform:2 channels,7 channels, 12 channels TEMP 0 - 40 mmHg: ± 2 mmHg
41 - 70 mmHg: ± 5% of reading
Display sensitivity(wave gain):
1.25mm/mV(×0.125), 2.5mm/mV (×0.25), 5mm/mV Accuracy:±0.1℃ or ±0.2℃ °F 71 - 100 mmHg: ± 8% of reading
(×0.5), 10mm/mV (×1.0), 20mm/mV (×2.0),40mm/mV Measurement range: 5~50℃(41~122°F) 101 - 150 mmHg: ± 10% of reading
(×4.0),Auto Channel:Two channels Respiration rate: 3-150 bpm
Wave sweep speed: Resolution: 0.1℃ Respiration rate accuracy: 1% ±1bpm
3.125mm/s, 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Parameters:T1,T2 and TD Warm-up time: 97% within 8s, full accuracy within 20s
Bandwidth
Diagnostic mode: 0.05Hz~100Hz NIBP Sidetream CO2(Optional)
Monitor mode: 0.5Hz~40Hz Measurement method : Automatic oscillometric method Measurement rage: 0-20%(0-150mmHg)
Surgery mode: 1Hz~20Hz Operating mode:Manual, automatic, continuous Accuracy: < 5.0% CO 2: ± 2 mmHg
Strong filter mode: 5Hz~20Hz Measurement unit: mmHg/kPa selectable > 5.0% CO 2: < 6% of reading
CMRR>100dB Typical measurement time: 20~40s Respiration rate: 2 ~ 150 BPM
Notch: 50/60Hz notch filter can be set to on or off Measurement type: Systolic, Diastolic,Mean Respiration rate accuracy: 1% ±1BPM
Differential input impedance>5MΩ Measurement range (mmHg) Warm-up time: 97% within 45s, full accuracy within 10 min
Graphical & Tabular Trend Electrode polarization voltage range: ±400mV Range of Systolic pressure: Adult 40-280 Rise times(t10-90%): About 100ms, when flow is 100 ml/min,
HR range: 15 - 350 bpm Pediatric 40-200 adult water trap,1.5m sampling tube
ST Measurement Range: -1.0 - +10 mv Neonatal 40-135 Delay time: <3sec when flow is 100 ml/min, adult water trap,
Baseline recovery time<3s after defibrillation (in monitor Range of Diastolic pressure: Adult 10-210
1.5m sampling tube
Pediatric 10-150
and surgery mode)
240 IBP(optional)
Neonatal 10-95
Hours long trend Calibration signal:1mV (peak - peak), accuracy ±3%
Range of Mean pressure: Adult 20-230
Pulse Rate Pediatric
Neonatal
20-165
20-105
Channel:2-channel or 4-channel

120
ART: 0 to 300 mmHg
Mins short trend Range: 30~300bpm Measurement accuracy PA: -6 to 120 mmHg
Resolution: 1bpm Maximum average error: ±5mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg
Accuracy: ±2bpm (non-motion) Maximum standard deviation: 8mmHg
Measurement range: P1/P2 -50 to 300 mmHg
1000 NIBP measurements ±5bpm (motion)
Refreshing rate: 1s
Resolution: 1mmHg
Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes
Resolution:1mmHg
Overpressure protection: Software and hardware, Accuracy:
double safety protection ±2% or ±1mmHg, whichever is greater(without sensor)
200 Alarm events SpO2 Cuff pressure range: 0-300mmHg Sensitivity: 5uV/mmHg/V
Impedance range: 300 to 3000Ω
Measurement range : 0-100%
Resolution: 1% Recorder (Optional)
Perfusion index display
Operation Environment
Built-in, Thermal dot array
Accuracy: ±2%(70-100%,Adult/Pediatric); Horizontal resolution :16 dots/mm (25 mm/s paper speed) Power: AC 100-250V, 50/60Hz
±3%(70-100%,Neonate); Vertical resolution:8 dots/mm Temperature: 5-40℃
0-69%,unspecified Paper speed:25 mm/s, 50 mm/s Humidity: <80%
Refreshing Rate: 1s Number of waveform channels:3 Patient Range: Adult, Pediatric, Neonate