0% found this document useful (0 votes)
47 views3 pages

Pip MS (PF1)

This document provides specifications for solar inverters in MPP Solar's PIP-MS/MG series. Key features include maximum power point tracking, support for up to 9 units in parallel, equalization charging up to 64V, and batteryless operation. Electrical specifications include continuous output power ranging from 1000W to 5000W depending on the model. Inputs include solar PV up to 450V and utility charging up to 80A. Optional accessories allow for parallel connection of multiple inverters and remote monitoring from a distance.

Uploaded by

Shared Mail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views3 pages

Pip MS (PF1)

This document provides specifications for solar inverters in MPP Solar's PIP-MS/MG series. Key features include maximum power point tracking, support for up to 9 units in parallel, equalization charging up to 64V, and batteryless operation. Electrical specifications include continuous output power ranging from 1000W to 5000W depending on the model. Inputs include solar PV up to 450V and utility charging up to 80A. Optional accessories allow for parallel connection of multiple inverters and remote monitoring from a distance.

Uploaded by

Shared Mail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

MPPT Max 64V @ 48V

HIGH DC INPUT 66V EQUALIZATION CHARGING

Batteryless
support*

Max 9 units PF = 1.0


PARALLEL SUPPORT* ENERGY EFFICIENT

*available on 5048MG only

PIP-MS/MG SERIES 1012MS 2024MS 3024MS 4048MS(1) 5048MS 5048MG


MAIN FEATURES ELECTRICAL SPECIFICATIONS
Continuous Output 1000W 2000W 3000W 4000W 5000W 5000W
● NEW! energy-efficient power factor 1.0 design Parallel-ready NO YES, MAX 9 UNITS
Batteryless Operation NO YES
● Parallel-ready up to 9 units (4-5K only) Input Power Factor 1
● Equalization charging up to 64V (MS 4-5K only) Input Voltage Range 90~280VAC (Appliance mode), 170~280VAC (UPS mode)
Input/Output Frequency 50Hz / 60Hz
● Max DC limit up to 66V (MS 4-5k only) Output Voltage 230VAC±5%
Output Waveform Pure Sine Wave
● High PV 450V input + Batteryless Operation Output Regulation < 3% RMS for battery voltage range
(MG 5k only) Output Short Circuit Circuit Breaker
Peak Efficiency 95% (line mode) / 91% (inverter mode)
● Bulk charge (C.V.) setting time
Transfer Time <10ms (UPS mode), <20ms (Appliance mode) **
● Built-in MPPT solar charger up to 80A Charging Mode 3-stage
Nominal DC Voltage 12V 24V 48V
● High frequency pure sine wave design Bulk Volt (Flooded, AGM) 14.6, 14.1V 29.2, 28.2V 58.4, 56.4V
Float Volt 13.5V 27.0V 54.0V 54.0V
● Suitable for with or without grid input
Max DC Volt 15.5V 31.0V 66.0V 63.0V
● Programmable parameters Max AC Charging Current 20Amp 30Amp 60Amp 80A
No Load Consumption <15W <25W <50W <50W
● Max up to 80A utility charging
Power Saving Mode <5W <10W <15W <15W
● Adjustable bulk/float voltage Solar Charger
Algorithm MPPT
● Wide AC input range System DC Voltage 12V 24V 48V 48V
● Lightweight, easy to install Max PV Input Voc 102V 75V 145V 450V
MPPT Range 15 - 80V 30 - 66V 60 - 115V 120 - 430V
● FREE monitoring software Max Charging Amp/Watt 40A, 500W 25A, 600W 80A, 4000W 80A, 4500W
ENVIRONMENTAL / MECHANICAL SPECIFICATIONS
● LCD Display + LED indicators Certification CE
Operating/Storage Temp. 0°C ~ 55°C / -15°C~ 60°C
Operating Humidity 20~90%RH Non-Condensing
Dimension 355*272*100mm 468*295*120mm
Net Weight 7.0Kg 7.0Kg 7.5Kg 12.5Kg 13.5Kg 11Kg
*MPP Solar Inc. reserves the right to change product specification without notice. MPP Solar is a registered trademark.
**Parallel Mode transfer time is 30ms
Special Features

**Product specifications are subject to change without prior notice. MPP Solar is a registered trademark of MPP Solar Inc.
Optional Accessories

This accessory is applicable to select


48VDC models of HS and MS series
inverters. It is a required component to
be installed in every unit of a parallel
system. A parallel kit includes:

● 1 X PARALLEL BOARD

● 1 X PARALLEL COMM CABLE

● 1 X CURRENT SHARING CABLE

*IMPORTANT: please do not attempt to parallel non-parallel-ready inverters together, as this will
result instant damage of all units!

This device is an extension of the HS/MS inverter’s


LCD module and allows user to implement control
on settings and monitoring from a distance away,
one unit at a time.

This remote module can coexist with the built-in


LCD display and is compatible with most models in
the HS/MS inverter series. Default operating
distance: 15m via RJ45 network cable (fixed length
cable included)

*For more details on pricing, availability and installation guide, please contact us directly.

**Product specifications are subject to change without prior notice. MPP Solar is a registered trademark of MPP Solar Inc.