Omron Socket Relay Catalog
Omron Socket Relay Catalog
CSM_common_sockets_DS_E_3_5
1
Products Related to Common Sockets and DIN Tracks
2
Products Related to Common Sockets and DIN Tracks
Ordering Information
Square Sockets
Model P2R (back-mounting), pages 11 and 12 P7TF (front-
P2RF (front-mounting), page 9
mounting), page 12
Number of pins Solder terminals PCB terminals
P2RF-05 P2RF-05-E* P2RF-05-S P2R-05A P2R-05P P2R-057P P7TF-05
Approx. 27 g Approx. 38 g Approx. 36 g Approx. 5 g Approx. 5 g Approx. 5.5 g Approx. 28 g
5 pins
8 pins
Note: 1. The structure of @-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
2. To remove the Relay, pull the lever on the Socket with your fingers supporting the lever and the opposite side of the Relay case, and
jiggle the Relay.
* Use a #1 Phillips screwdriver to tighten the screws on this Socket.
Minimum Order Lot The following models are available at the minimum order lot specified below.
Number of pins Model P2RF P2R P7TF Minimum order lot (pcs)
5 pins P2RF-05 P2R-05A P2R-05P P7TF-05
10
8 pins P2RF-08 P2R-08A P2R-08P ---
8 pins PYF08S
PYF08A-E *1
Approx. 46 g
1 ?
11 pins
14 pins PYF14A-E*1
PYF14S
Approx. 62 g
3
Products Related to Common Sockets and DIN Tracks
Note: 1. The structure of @-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
2. Refer to Models with Standards Certification for detailed information on the models of Common Sockets that are certified for standards.
*1. Use a #1 Phillips screwdriver to tighten the screws on this Socket.
*2. The structure does not resist flux. Manual soldering is recommended for this product.
Note: The structure of @-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
* Use a #1 Phillips screwdriver to tighten the screws on this Socket.
* The structure does not resist flux. Manual soldering is recommended for this product.
Minimum Order Lot The following models are available at the minimum order lot specified below.
Model
Number of pins PYF PY PTF PT Minimum order lot (pcs)
PYF08A
8 pins PY08 PTF08A PT08
PYF08M
10
11 pins PYF11A PY11 PTF11A PT11
14 pins PYF14A PY14 PTF14A PT14
14 pins
P7SA-14F Approx. 59 g P7SA-14P Approx. 10 g
P7SA-14F-ND Approx. 59 g
Note: Refer to Models with Standards Certification for detailed information on the models of Common Sockets that are certified for standards.
4
Products Related to Common Sockets and DIN Tracks
Round Sockets
Model PL (back-mounting), page 26
PF (front-mounting), P2CF (front-mounting), PFA (front-mounting), P3G (back-mounting),
Number page 22 page 23 page 24 page 25 Solder Wrapping PCB
of pins terminals terminals terminals
PF083A P2CF-08 8PFA P3G-08 PL08 PL08-Q PLE08-0
Approx. 34 g Approx. 55 g Approx. Approx. 40g Approx. 14 g Approx. 15 g Approx.
57 g 10.6g
PF083A-E *
P2CF-08-E
8 pins 8PFA1
Note: The Y92A-48G
Approx. Terminal Cover
66 g can be used to
PF085A provide finger
Approx. 40 g protection.
11 pins
PF113A-E * P2CF-11-E Note: The Y92A-48G
Terminal Cover
can be used to
provide finger
protection.
PL20
Approx. 17 g
Note: The structure of @-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
* Use a #1 Phillips screwdriver to tighten the screws on this Socket.
Minimum Order Lot The following models are available at the minimum order lot specified below.
Number of
pins
Model PF P2CF PFA P3G PL
8 pins PF083A, PF085A P2CF-08, P2CF-08-E 8PFA. 8PFA1 P3G-08 PL08
11 pins PF113A P2CF-11, P2CF-11-E 11PFA P3GA-11 PL11
14 pins --- --- 14PFA --- PL15
Minimum order lot
20 10 20 10
(pcs)
Terminal Cover
Model Y92A-48G
Appearance
Note: Refer to Models with Standards Certification for detailed information on the models of Common Sockets that are certified for standards.
5
Products Related to Common Sockets and DIN Tracks
29 29 max. Approx. 3
7°
71.8 42.8 36.3
36.3
PYC-P2 Approx. 1.2 g PYC-S Approx. 1.8 g PYC-1 Approx. 6 g PYC-2 PYC-3 PYC-5
9.4
10 8 5 10
8
28
28 28.8 Approx. 3
28 29.5
3.7
2.5
4.6 4.6
4.6
69.2 65.7
60.8 73.3 56.6 56.3
62 74.5 94
95.2
7.6 8
8
6 4.5
6 4.5 9
6 4.5
6
Products Related to Common Sockets and DIN Tracks
Specifications
Socket Characteristics
Continuous Insulation
Model Dielectric strength Remarks
carry current resistance*1
Between contact terminals of same polarity: 1,000 VAC for 1 min
P2RF-05(-E)(-S) 10 A 1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
Between contact terminals of different polarity: 3,000 VAC for 1 min
P2RF-08(-E)(-S) 5A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
Between contact terminals of same polarity: 1,000 VAC for 1 min
P2R-05P 10 A 1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
Between contact terminals of different polarity: 3,000 VAC for 1 min
P2R-08P 5A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
Between contact terminals of same polarity: 1,000 VAC for 1 min
P2R-057P 10 A 1,000 MΩ min.
Between coil and contact terminals: 5,000 VAC for 1 min
Between contact terminals of different polarity: 3,000 VAC for 1 min
P2R-087P 5A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 MΩ min.
Between coil and contact terminals: 5,000 VAC for 1 min
Between contact terminals of same polarity: 1,000 VAC for 1 min
P2R-05A 10 A Between ground terminals: 1,500 VAC for 1 min 1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
Between contact terminals of different polarity: 3,000 VAC for 1 min
Between contact terminals of same polarity: 1,000 VAC for 1 min
P2R-08A 5A 1,000 MΩ min.
Between ground terminals: 1,500 VAC for 1 min
Between coil and contact terminals: 4,000 VAC for 1 min
P7TF-05 5A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
The continuous carry current of 10
A for the PYF08S is for an
7 A, -S models:
PYF08A(-E)(-S) Between terminals: 2,000 VAC for 1 min 1,000 MΩ min. ambient temperature of 55°C.
10 A
At an ambient temperature of
70°C, the value is 7 A.
PYF11A 5A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
3 A, -S models:
PYF14A(-E)(-S) Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
5A
PY08(-Y1) 7A Between terminals: 1,500 VAC for 1 min 1,000 MΩ min.
PY08QN(-Y1) 7A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY08-02 7A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11(-Y1) 5A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11QN(-Y1) 5A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY11-02 5A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14(-Y1) 3A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14QN(-Y1) 3A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PY14-02 3A Between terminals: 1,500 VAC for 1 min 100 MΩ min.
PTF@@A(-E) 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT@@ 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT@@QN 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
PT@@-0 10 A Between terminals: 2,000 VAC for 1 min 100 MΩ min.
Between contact terminals of different polarity: 2,000 VAC for 1 min
P7LF-06 30 A Between contact terminals of same polarity: 2,000 VAC for 1 min 1,000 MΩ min.
Between coil and contact terminals: 4,000 VAC for 1 min
PF@@@A 5A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P2CF 5A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
P3G(A) 6A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
8PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
11PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PL@(-Q) 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
PLE@@-0 10 A Between terminals: 2,000 VAC for 1 min 1,000 MΩ min.
Between contact terminals of same polarity: 1,000 VAC for 1 min
P6D-04P 5A 100 MΩ min.
Between coil and contact terminals: 3,000 VAC for 1 min
Between contact terminals of different polarity: 2,000 VAC for 1 min
P7S-14@-E(ND) 10 A Between contact terminals of same polarity: 1,500 VAC for 1 min 1,000 MΩ min.
Between coil and contact terminals: 2,000 VAC for 1 min
7
Products Related to Common Sockets and DIN Tracks
Continuous Insulation
Model Dielectric strength Remarks
carry current resistance*1
Between contact terminals of different polarity: 2,500 VAC for 1 min
P7SA-10@ 6 A *2 Between contact terminals of same polarity: 1,500 VAC for 1 min 1,000 MΩ min.
Between coil and contact terminals: 2,500 VAC for 1 min
Between contact terminals of different polarity: 2,500 VAC for 1 min
P7SA-14@ 6 A *2 Between contact terminals of same polarity: 1,500 VAC for 1 min 1,000 MΩ min.
Between coil and contact terminals: 2,500 VAC for 1 min
*1. The insulation resistance was measured with a 500-VDC insulation resistance meter at the same places as those used for measuring the
dielectric strength.
*2. There are restrictions in the current. Refer to the General Catalog for the OMRON Safety Components (Cat. No. Y106) for details.
Safety Precautions
Refer to Common Relay Precautions for general precautions.
8
Products Related to Common Sockets and DIN Tracks
Dimensions
P2RF (Unit: mm)
Terminal Arrangement/
Dimensions Mounting Hole Dimensions
Internal Connections
P2RF-05 7±0.2 2
(One Pole) 5-M3.5×8
4.2-dia. hole
4 dia.
9.5
4
35.5 30±0.05
71.5 max. 3
4
M3 (M3 x 16)
or 3.2-dia. hole
2
19.5
5 1
4
19.5 max. 30 max. (Top View)
54 max.
(Top View) Note: Track mounting is also possible.
Refer to page 27.
3.2-dia. hole
59 max. 4 (11)
7
(80.9 max.)* 2 (12) 2
5-M3.5×7 48 max.
3 (14)
39.5±0.1
3.5-dia. hole 4
39.5
(A1)
5
85.5 max. M3 or 3.5-dia. hole
35.5 (A2) 1
(Top View)
(Top View)
Note: Figures in parentheses
indicate DIN standard
*When mounted numbers. Note: Track mounting is also possible.
4 16
11.5
on H3RN-1@. Refer to page 27.
61 max.
---
35.3
91.8 max.
(A1) (A2)
5 1
(Top View)
Note: Figures in parentheses
28.5 (5.3) indicate DIN standard
(2.4)
numbers.
32.6
P2RF-08 7±0.2 2
6 3 30±0.05
71.5 max. 35.5
5 4 4
M3 (M3 x 16)
or 3.2-dia. hole
7 2
4 19.5 8 1
19.5 max. (Top View)
30 max.
54 max.
(Top View) Note: Track mounting is also possible.
Refer to page 27.
9
Products Related to Common Sockets and DIN Tracks
P2RF-08-E
(Two Poles) 6+0.2
−0.1
(21) (11)
6 3
(Finger Protection Structure) (22) (12)
63 max.
7 2 3.2-dia. hole
24.5
---
35.3
91.8 max. (A1) (A2)
8 1
(Top View)
Note: Figures in
parentheses
(2.4) 28.6 (5.3) indicate DIN
32.6 standard numbers.
Note: 1. If an I/O SSR or Indicator Module is used, the polarity of terminal 1 is negative.
2. Refer to pages 28 and 30 for the features of Screwless Sockets and for precautions for correct use.
10
Products Related to Common Sockets and DIN Tracks
4 7 7
0.3 4 5
5
3 6 5
5 2 7 5
35.5 max. 1
2.8 20
20
1 8
1.5 (4.3)
7.5
6 3
6±0.1
4.5 4
29.6 15 4.5±0.1
37 max.
4 2 15±0.1
1 8.75
4±0.1
8.7 7.4 1 (8.75)
5
7±0.1
4 7
5 4 5
5 3 6 5
37 max. 29.1 1 20 5
2 7
8.1 20
8.9 7.4
1 8 (8.1)
7.5
Note: If an I/O SSR or Indicator Module is used, the polarity of terminal 1 is negative.
11
Products Related to Common Sockets and DIN Tracks
7.5 4.5
14.5 max.
1.2
0.3 3
4
6.7
2
35.5 max. 5 16.7
3.8
1 5
Five, 3 x 1.8-dia. holes
13.6±0.1
6
(Bottom View)
36.5 max.
30.5+00.2
P2R-08A (Two Poles)
7.5
14.5 max. 6.5
1.2 4 5
0.3 (Use panel with thickness of
3 6 1.6 to 2.0 mm.)
5
5 2 7
35.5 max.
2.6 20
2.8
1 8
Eight, 3 x 1.2-dia. holes 1.5
7.5
(Bottom View)
36.5 max.
Note: If an I/O SSR or Indicator Module is used, the polarity of terminal 1 is negative.
12.5±0.2
P7TF-05 M3 or M4*
19 max.
7+0.2
-0
5-M3.5×8
4 62±0.1
3 2
1 M3
5 (Top View)
Note: Track mounting is also possible.
4
9
Refer to page 27.
* We recommend that you use washers
12.5±0.2 19.5
(Top View) if you use M3 bolts or screws.
59 max. Washers are not required with M4
bolts or screws.
Note: If an I/O SSR or Indicator Module is used, the polarity of terminal 1 is positive.
12
Products Related to Common Sockets and DIN Tracks
PYF08A PYF08A-E
Two M3 or M4
(Finger Protection Structure) or 4.5-dia. holes
12 9
14 13 15±0.2
(Top View)
4 4
(Top View)
4
6 6 Note: Track mounting is also
23 max. 23 max.
16.5 16.5 possible.
30 max. 31 max. Refer to page 27.
PYF08M 8-M3.5×7.5
3 dia.
7±0.2 4 1
3.5-dia. hole
8 5
33.5 max.
12 9
20±0.1 3.5-dia. or M3 hole
14 13
44.5 max. 1.5
18 max. (Top View)
3.5-dia. mounting holes
6.5-dia. countersinking, depth: 11.5
12 9
(41) (11)
8 5
(44) (14)
32.6
27.6 4 1
23.2 max. (42) (12)
22.6 (3.4)
24.5 ---
(A2) (A1)
85 max. 35.4 14 13
(Top View)
Note: Figures in
parentheses
indicate DIN
(5) 28.6 (5.3) standard
32.6 numbers.
3 2 1
6 5 4 59±0.3
72 max. 35.4
9 8 7
11 10 22±0.2
4 (Top View)
29.5 max.
6 (Top View) Note: Track mounting is also
16.5 possible.
30 max.
Refer to page 27.
13
Products Related to Common Sockets and DIN Tracks
PYF (Unit: mm)
Terminal
Dimensions Arrangement/Internal Mounting Hole Dimensions
Connections
PYF14A PYF14A-E
Two M3 or M4
(Finger Protection Structure) or 4.5-dia. holes
Two, 4.2 × 5 6+0.2 Two, 4.2-dia × 5
−0.1 3.4 6+0.2
−0.1 3.4
mounting holes mounting holes
14-M3×8 14-M3×8
59±0.3
22±0.2
(Top View)
4 4 4 3 2 1
6 6 8 7 6 5 Note: Track mounting is also
29.5 max. 29.5 max.
16.5
possible.
16.5
30 max. 31 max. Refer to page 27.
12 11 10 9 2-M4
PYF14T 30
4 14 13
23.5
33 max. 11.5
Two, 4.2-dia × 5 7±0.2
mounting holes 11
(Top View)
59
70 max. 35.5
24.5
(Top View)
17.8 Note: Track mounting is also
possible.
4
14-M3.5×8 Refer to page 27.
17.4 10
8 7 6 5
(44) (34) (24) (14)
32.6 4 3 2 1
27.6 (42) (32) (22) (12)
31 max. 22.6 (3.4)
24.55 ---
(A2) (A1)
85 max. 35.4
14 13
(Top View)
Note: Figures in
parentheses
indicate DIN
(4.15) 28.6 standard
32.6 numbers.
Note: Refer to pages 28 and 30 for the features of Screwless Sockets and for precautions for correct use.
14
Products Related to Common Sockets and DIN Tracks
PYD-020B@(2P)
Max. carry current: 20 A (18 A at 70°C)
3.2 Ambient operating temperature: -40 to 70°C (with no
icing or condensation)
7 5.6 Ambient operating humidity: 45% to 85% (with no
PYF14A
mm icing or condensation)
7 7 Conductor material: Brass
Conductor surface treatment: Nickel plating
Package qty: 50/bag
PYD-030B@(3P)
3.2
5.6
Note: 1. The @ in the model number is replaced with the insulation color specification code. B: Black, Y: Yellow
2. Specify the number of bags when ordering.
22 40°
PYD-025B@(2P)
Max. carry current: 20 A (18 A at 70°C)
3.3 Ambient operating temperature: -40 to 70°C (with no
5.6
icing or condensation)
22 Ambient operating humidity: 45% to 85% (with no
PYF08A
mm 154
icing or condensation)
40° Conductor material: Brass
22
Conductor surface treatment: Nickel plating
Package qty: 10/bag
PYD-085B@(8P)
3.3
5.6
29 40°
PYD-026B@(2P)
Max. carry current: 20 A (18 A at 70°C)
3.3 Ambient operating temperature: -40 to 70°C (with no
5.6
icing or condensation)
29 Ambient operating humidity: 45% to 85% (with no
PYF14A
mm 203 icing or condensation)
29 40° Conductor material: Brass
Conductor surface treatment: Nickel plating
PYD-086B@(8P) Package qty: 10/bag
3.3
5.6
Note: 1. The @ in the model number is replaced with the insulation color specification code. B: Black, S: Blue, R: Red
2. Specify the number of bags when ordering.
Socket Bridges
Pitch Applicable models Appearance and dimensions (mm) Model Insulation color
19.7 Insulating coating PYDM-08SR Red
PYF08S
mm PYDM-08SB Blue
27.5 PYDM-14SR Red
PYF14S 14
mm 9 PYDM-14SB Blue
14.3 P2RM-SR Red
P2RF-@@-S Pitch
mm Guide: 1.2 dia. P2RM-SB Blue
Note: 1. Use the Socket Bridges for relay coil bridge wiring.
2. Specify the number of bags when ordering.
Safety Precautions
Maximum Carry Current
• The total current of all bridged poles must not exceed the maximum carry current of the Socket Bridge.
• Make sure that the maximum carry current of the relay contacts is also not exceeded for each pole.
• If you use more than one Socket, use End Plates (PFP-M).
15
Products Related to Common Sockets and DIN Tracks
PY (Unit: mm)
Terminal
Arrangement/
Dimensions Mounting hole and PCB dimensions
Internal
Connections
PY08 *
Eight, 3 x 1.2 ellipses
PY08-Y1 (L = 42 max.)
PY08-Y13 (L = 60 max.) 25.5 max.
29.5 max.
5
PY08QN 1 4
1
PY08QN2 *1
29.5 max.
PY08QN-Y1 5
5 8
*2
PY08QN2-Y1 2.7
(20)
25
9 12
*1. The PY08QN(2)-Y1 includes the part 22 max.
41.5 max. 13.2
outlined by the dashed lines above. (36.5 max.)*2 24 max. 13 14
*2. The figures in the parentheses are for 42 max.
the PY08QN2(-Y1). (Bottom View) 5.8
4.1
1.0
PY08-02 12.65
* The structure does not resist flux. Manual 6.35
0.3
soldering is recommended for this product. 6.4
25.5 max.
29.5 max.
4.2 Eight, 1.3-dia holes
2.7 4.3 2
22 max.
16.5 max.
21.46+0.2
0
PY11QN 1
PY11QN2 *1 1 2 3
29.5 max.
PY11QN-Y1 5
4 5 6
(20)*2
PY11QN2-Y1 2.7 25
22 max. 7 8 9
*1. The PY11QN(2)-Y1 includes the part 41.5 max.
outlined by the dashed lines above. (36.5 max.)*2 24 max.
13.2
42 max. 10 11
*2. The figures in the parentheses are for
the PY11QN2(-Y1). 5.8
(Bottom View)
4.1
1.0
PY11-02
12.65
* The structure does not resist flux. Manual 6.35
soldering is recommended for this product. 0.3
25.5 max. 6.4
29.5 max.
4.2 Eleven, 1.3-dia holes
2.7 4.3 2
22 max.
16.5 max.
16
Products Related to Common Sockets and DIN Tracks
Terminal
Arrangement/
Dimensions Mounting hole and PCB dimensions
Internal
Connections
25.8±0.2
*
The PY14-Y@ includes 2.7 7.7 2.6
the part outlined by the
dashed lines above. 20 max. 24 max.
L 21.4+0.2
0
PY14QN 1
*1
PY14QN2 29.5 max.
5 1 2 3 4
PY14QN-Y1 (L = 42 max.)
(20)*2
PY14QN2-Y1 (L = 42 max.) 2.7 25 5 6 7 8
22 max.
PY14QN-Y3 (L = 60 max.) 41.5 max.
(36.5 max.)*2 24 max. 9 10 11 12
L
PY14QN2-Y3 (L = 60 max.)
*1. The PY14QN-Y@ and PY14QN2-Y@ include the part outlined 13 14 13.2
by the dashed lines above.
*2. The figures in the parentheses are for the PY14QN2(-Y@). (Bottom View) 4.4
5.8
1.0
PY14-02 4.1
* The structure does not resist flux. Manual
soldering is recommended for this product. 0.3 12.65
25.5 max. 6.35
29.5 max. 6.4
Fourteen
4.2 1.3-dia. holes
2.7 4.3 2
22 max.
16.5 max.
2 1
8
28.5 max. 4 3
30 max.
Two, 4.5 × 6
3.4 6 5
mounting holes 8-M3.5×8
8 7
(Top View)
78.5 max. 35.5
17
Products Related to Common Sockets and DIN Tracks
Terminal Arrangement/
Dimensions Mounting Hole Dimensions
Internal Connections
9 8 7
11 10
27.5±0.2
(Top View)
(Top View)
37 max. 8
Note: Track mounting is also possible.
30 max.
Refer to page 27.
4 3 2 1
45.5 max. 8 8 7 6 5
30 max.
(Top View)
78.5 max. 35.5
Note: Track mounting is also possible.
Refer to page 27.
45.5 max. 8
33 max.
Note: If you use the PTF08A, PTF08A-E, or PT08 with an LY1 Relay, connect the following terminal pairs: 1-2, 3-4, and 5-6 (for usage at 10 A or
higher).
PT (Unit: mm)
Terminal
Arrangement/
Dimensions Mounting hole and PCB dimensions
Internal
Connections
PT08 PT08QN
5 1.5×1.0
12.45
29.5 max. 6.45
2 5* 6.5
6.5
18
Products Related to Common Sockets and DIN Tracks
Terminal
Arrangement/
Dimensions Mounting hole and PCB dimensions
Internal
Connections
PT11 PT11QN
0.3
1.5×1.0
32 9 2.5
30.6 2.7 20 1.0
max.
35 max. 1.2 26.4
26.6+0.3
0
2.7 1.2 26.4 29.5 max.
10 7 4 1
20.5 max. 29.5 max.
8 5 2
PT11-0 *Maintain 12.45
a sufficient distance from the 11 9 6 3
0.3 pattern when using double-sided PCBs. 6.45 4.6
• The structure does not resist flux. Eleven,
Manual soldering is recommended for 2.5-dia. holes
5.2
this product. (Bottom View)
10
21.4
2 5* 32 max. 10
5.8
PT14 PT14QN
0.3
1.5×1.0
5
42.5 max.
9 2.5
2.7 20 1.0
35 max.
26.5 max. 26.6+0.3
0
2.7 29.5 max. 13 9 5 1
26.5 max.
20.5 max. 29.5 max.
10 6 2
PT14-0 *Maintain 11 7 3 12.45
a sufficient distance from the 4.6
0.3 pattern when using double-sided PCBs. 6.45
• The structure does not resist flux. 14 12 8 4
Manual soldering is recommended for 5.1 5.8
this product.
(Bottom View) 10
31.4 10
42.5 max.
2 5* 10
Fourteen,
2.5-dia. holes
2.7 4.3 6.4
6.4 5.45
17.5 max. 26.5 max.
(±0.1 tolerance)
29.5 max.
19
Products Related to Common Sockets and DIN Tracks
51.5 max.
9.2±0.05
P7S-14F-END
Indicator LED
14-M3.0×8
40 max.
33±0.1
41 42
4 43 44
1
7.5 33 Two, 4.0 dia.
24 34 or M3.5
23 62
14 61 33±0.1
13 51
0 52
80 max.
37
17
5 3.1 5.9
90.5 max.
(5)
P7S-14P-E
70.5 max.
28±0.2 G7S-4A2B-E Mounted
23.5 max.
28±0.2
(21)
Two, 6.5 dia., depth: 8 4.2
2.8
(16.9)
57 max.
Fourteen, 6 7 Two,
2.5 dia. 5×7=35 3.6 dia.
13.2
6 7 (15) 4.1
8
5×7=35 16.9
14.5
23.5 max.
20
Products Related to Common Sockets and DIN Tracks
43 43
24 22
80±0.2
72 max. * *
23 21
Indicator
LED
12 12
11 1 0 11 1 0
9 max.
(Top View)
4 dia.
* This display circuit is available only for "-ND" models.
Note: 1. The Socket is shown with the finger
cover removed. Note: Terminals 23-24, 33-34, and 43-44 are normally
2. Only the -ND Sockets have LED open. Terminals 11-12 and 21-22 are normally
closed.
indicators (orange).
44 34 44 34 44 32
* * *
43 33 43 33 43 31 80±0.2
72 max.
24 12 22 12 22 12
Indicator
LED
23 1 0 11 21 1 0 11 21 1 0 11
G7SA-4A2B Mounted
0 11 12 33 34 53 54 Three, 3.2 dia.
49.9±0.2 (for M3 tapping
+ 24.8±0.2 Fourteen,
41.5 max. − 4.1±0.2 1.1 dia. holes screws)
1 21 22 43 44 63 64
10.16
G7SA-3A3B Mounted
13.97 11.43
0.4 3.5 0 11 12 31 32 53 54 (7.14) 5.08
(11.1) (11.1) 0.8 5.08 5.08 5.08
+
−
Three, 2.6 dia.
(for M3 tapping screws) 1 21 22 43 44 63 64 (Bottom View)
(Bottom View)
4.1 24.8
Note: Terminals 23-24, 33-34, 43-44, 53-54, and 63- (±0.1 tolerance)
49.9 64 are normally open. Terminals 11-12, 21-22,
and 31-32 are normally closed.
21
Products Related to Common Sockets and DIN Tracks
PF (Unit: mm)
Terminal Arrangement/
Dimensions Mounting Hole Dimensions
Internal Connections
PF083A 4
8-M3.5×7 7±0.2
Two,
4.2 dia. holes
52 max. 35.4
2 1 8 7
4 33 3.5 2
41 max.
21 max.
33±0.2
4
23 3.5 2 Note: Track mounting is also
33 possible.
21 max. Refer to page 27.
41 max.
PF085A 4
8-M3.5×7 7±0.2
6 5 4 3
Two,
4.5 dia. holes
58 max. 35.4
7 8 1 2
4 33±0.2 1.1 2
3.5
40 max. (Top View)
21.6 max.
PF113A 11-M3.5×7
4
22 7±0.2
52 max. 35.4
4 2 1 11 10
5 34 4 3.5 2 3 9
43 max. 31 max. Two M4 or 4.5-dia. holes
4
5.2 3.5
23 5.5
42.8 31 max.
Note: 1. For the PF083A and PF113A, the Socket key slot is on the top. (Applicable model: MK)
2. The structure of @-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
22
Products Related to Common Sockets and DIN Tracks
P2CF-08 8-M3.5×7.5
7.8 3 4.5
Two,
4.5 dia. holes
70 max. 35.4
6 5 4 3
4 50 max.
20.3 max.
Two M4 or 4.5-dia. holes
P2CF-08-E 8-M3.5×7.5
7.8 5 4.5
40±0.2
6 5 4 3
3
P2CF-08-E
Two, 7 8 1 2
4.5 dia. holes
Note: Track mounting is also
70 max.
1.3 (Top View) possible.
35.4
Refer to page 27.
10A250VAC
RESISTIVE
7 8 1 2
4 40±0.2 19
50 max.
20.3
21.5 max.
P2CF-11 11-M3.5×7.5
7.8 3 4.5
Two,
4.5 dia. holes
70 max. 35.4
8 7 6 5
50 max.
4
4 31.2 max. Two M4 or 4.5-dia. holes
10 11 1 2
4 40±0.2 30
50 max. 31.2 max.
23
Products Related to Common Sockets and DIN Tracks
8PFA
8-M3.5×7 7.8±0.2
Two, 4
4.5 dia. holes
5 4
118
81 max. 35.4
max.
4 40±0.2 6 5 4 3
51 max.
24 max. Two M4 or 4.5-dia. holes
8PFA1 40±0.2
8-M3.5×7 7.8±0.2
7 8 1 2
4 Note: Track mounting is also
Two, (Top View) possible.
4.5 dia. holes
Refer to page 27.
5 4
130
93 max. 35.4
max.
4 40±0.2
51 max.
24 max.
11PFA
11-M3.5×7 7.8±0.2
Two, 4
4.5 dia. holes 8 7 6 5
4
5 4
118 Two M4 or 4.5-dia. holes
81 max. 35.4
max.
40±0.2
9 3
10 11 1 2
Note: Track mounting is also
4 40±0.2 (Top View) possible.
51 max. Refer to page 27.
33.5 max.
14PFA
14-M3.5×7 7.8±0.2
4
Two, 7 14 6 5 12 4
4.5 dia. holes
5 4 3 Two, 4.5 dia. or M4 mounting holes
118
81 max. 35.4
max.
60±0.2
8
9 15 10 1 11 2
Note: Track mounting is also
4 60±0.2 (Top View) possible.
72 max. Refer to page 27.
33.5 max.
24
Products Related to Common Sockets and DIN Tracks
P3G-08 27 dia.
3 4 5 6
45
---
2 1 8 7
Eight,
45 4.9 17 M3.5 SEMS screws (Bottom View)
Note: The Y92A-48G Terminal Cover can be used to
implement finger protection.
P3GA-11 27 dia.
5 6 7 8
4
45 25.6
3 9 ---
2 1 11 10
Eleven,
45 4.5 6.2 M3.5 SEMS screws (Bottom View)
16.3
34 Y92A-48G
UP
47.7 × 47.7 48 × 48
P C
16.5
24.6 27.6
47.4
16
PYF08S PYCM-08S
54.4
32.7
28
PYF14S PYCM-14S
52.5
29.6
16.8
P2RF-05-S
40.35
P2CM-S
P2RF-08-S 36
25
Products Related to Common Sockets and DIN Tracks
PL (Unit: mm)
Terminal Arrangement/
Dimensions Mounting hole and PCB dimensions (bottom view)
Internal Connections
Two, 3.5 dia. or M3 L = 40 mm
PL08 device mounting holes
MK2(Z)P
3.5
4 1 Two, 3.5 or M3 L = 74 mm
Socket mounting holes
Two, PU, AMD-S, MM2(X)P, CZ, STP, H3L,
2 dia. holes TDS, DTS, DSP, TDF, TDV
L = 86 mm
31-dia. hole 61F-GP/-APN, G4Q-212S, RD2P,
50.5 max.40 30 dia. 40±0.3 L
RDA, TDA, AGF, SE, SAD, K2CU,
3.9 SDV-F
Approx.
50.5 max. 20.5
2 7
51 max. 40 30 dia. 1 8 MK2(Z)P
31-dia. hole
40±0.3
16
(Bottom View)
35 max. 35 max.
PL11 3.5 4 1
Two 2-dia.
holes
31-dia. hole
PL11-Q 3.5 4 1 40±0.3 L
L = 42 mm
5 6 7
MK3ZP
t0.6×1.3 4 8
MK3LP
3 9
51 max. 2 10
1 11
16
(Bottom View)
35 max. 35 max.
22 max.
Eleven, 2.5-dia. holes
4
PL15 4 1
Two, 3.5 dia. or M3
device mounting holes
MM3XP
Two 2-dia. MM4(X)P
Two, 3.5 dia. or M3
holes
2 3 4 Socket mounting holes MM3(X)KP
12
66 max. 53 41 max. 1 11 5 4.2-dia. hole MM4(X)KP
13 74
3.9 10 15 6
14
9 8 7
(Bottom View)
45 max.
22 max.
53
26
Products Related to Common Sockets and DIN Tracks
Terminal Arrangement/
Dimensions Mounting hole and PCB dimensions (bottom view)
Internal Connections
Note: When mounting, pay due attention to the direction of the key groove of applicable Relays.
DIN Tracks
PFP-100N 7.3±0.15
PFP-50N 4.5
35±0.3 27±0.15
Model
15 25 25 25 25 15 (5)*
PFP-100N
1
10 10
1,000 (500)* *
PFP-50N
Dimensions in parentheses are for the PFP-50N.
DIN Track 16
PFP-100N2 4.5
35±0.3 27 24 29.2
Model
15 25 25 25 25 15 1 1.5
10 10 PFP-100N2
1,000
End Plate 10
6.2
PFP-M 1.8
M4×8
panhead
screw 1
50 35.5 35.3
1.8
11.5
Model
10 1.3 PFP-M
M4 screw and washer 4.8
16
Spacer 5 12
PFP-S
34.8
44.3
Model
PFP-S
16.5
27
Products Related to Common Sockets and DIN Tracks
Safety Precautions
Precautions for Safe Use
• Do not move the screwdriver up, down, or from side to side or rotate it while it is inserted in the hole. Doing so may damage internal components in the
Socket.
• Do not insert more than one wire into the same hole. Doing so may cause abnormal heating.
• There are two internally connected wiring holes for each terminal.
• Insert the screwdriver along the hole wall as shown below.
Screwdriver
• When you remove a Socket from a support rail, insert the end of a screwdriver into the fixture and move the driver as shown by the arrow in the
following figure.
Screwdriver
Fixture rail
• When you use a Release Lever to remove a Relay from a P2RF-@@-S Socket, insert a screwdriver at the location shown in the following figure
and move the Release Lever in the direction indicated by the arrow to release the lock on the release lever.
28
Products Related to Common Sockets and DIN Tracks
Precautions for Correct Use
Wiring Tools
Applicable Screwdriver
Use a flat-blade screwdriver with a tip that is 2.5 mm wide (3.0 mm
max.).
Applicable Wires
• You can use either solid wires or stranded wires. Applicable wire
size: 0.2 to 1.5 mm2 (AWG24 to AWG16)
• Strip 8 to 9 mm of insulation from the ends of the wires.
8 to 9 mm
• If you insert stranded wires without ferrules, make sure that the
wires are twisted when you insert them.
• If you use bare ferrules, always attach insulating sleeves.
• If you insert a wire with a sheath outer diameter of 2.2 mm or less,
do not insert the wire far enough so that the sheath is engaged
inside the hole, as shown below.
29
Products Related to Common Sockets and DIN Tracks
Wiring
12 11 10 9
Wire insertion holes
41 31 21 11
Screwdriver insertion hole
Screwdriver
(2) Press the screwdriver in until it reaches the stopper inside the
Socket. The spring at the back of the wire insertion hole will be
complete open in this condition. The screwdriver will be held in place
even if you remove your hand.
(3) With the screwdriver held in place, insert the wire or ferrule into the
wire insertion hole.
Wire
(4) Remove the screwdriver. The spring will hold the wire. This
concludes the connection procedure.
30
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
2017.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2017 All Right Reserved.