icountBS - Bottle Sampler
The benchtop solution to fluid contamination
bottle sampling
17
The Complete Solution - Industrial
Design Combined with State of the
Art Technology
The icountBS - Bottle Sampler from
Parker, with its innovative industrial
The IBS features an easy to
use interactive touch screen,
icountBS - Bottle
design, has been developed for
customers looking for state of
environmentally controlled pressurized
bottle chamber, an internal
Sampler Features &
the art technology, attention to compressor pump, automated door Benefits
detail and the compactness of locking mechanism, sample tube
a permanent laboratory particle cleaning sleeve that minimizes cross • Customer programmable number
analysis instrument. contamination, and an internal printer. of sample runs/sample bottle
averaging and pre-test flush
Combine this with on-board, laser The icountBS benefits from Parkers volumes from 10ml min. to 100ml
based, leading edge technology knowledge and experience of max.
to bring to all industries a truly providing fluid analysis equipment to
revolutionary Particle Counter. The the market for over 15 years. • Input via fluid resistant touch screen
innovative icountBS is a product display.
from the next generation of Parker’s
fluid particle analysis and monitoring • Repeatable and reproducible
solutions. performance to ISO4406:1999,
AS4059 Rev E, and NAS1638 particle
count distributions. Other calibration
standards are included.
• On-board compressor and ‘shop’ air
capable.
• Design concept allowing for
portability. DC and rechargeable
battery pack options built in.
• Sample tube self cleaning sleeve
minimizing cross contamination.
• 500 test sample memory.
• Data download via USB jump drive
or USB to USB included.
• Internal printer.
18
Home Screen Sample ID Input Number of Sample Runs
Sample Volume Flush Volume Start Test
19
Analyzing the Test Results
Once the automatic oil levels relating to three sizes. 1,300 - 2,500 particles that
sample test has been The first scale number are equal to and greater than
completed, what next? represents the number of 6μm(c), and between 80 - 160
particles that are equal to and particles that are equal to and
Solid contaminants in fluid greater than 4μm (c) per ml of greater than 14μm(c).
power systems vary in size, fluid, the second number for
shape, form and quantity. The particles that are equal to and
most harmful contaminants greater than 6 μm(c) per ml of
are normally between 6 fluid and the third number for
microns and 14 microns. The particles that are equal to and
ISO code is the preferred greater than 14 μm(c) per ml
method of reporting quantity of fluid.
of contaminants.
For example: An ISO code
The ISO code number 20/18/14 indicates that there
corresponds to contamination are between 5,000 - 10,000
particles that are equal to and
greater than 4μm(c), between
20
icountBS Product Specification
Principle of Operation Laser based light obscuration
Dimensions H=20.9” x W=7.48” (8.27” Door) x D=16.1”
Weight 31 lb. (14kg)
Mechanical Composition Stainless steel 316, plated mild steel and aluminum
Plastics Composition Precision polyurethane RIM moldings and ABS plastic
Environmental Operating Temperature
41°F to 140°F (+5°C to +60°C)
(Tested)
Operating RH Range 20 - 85% [Tested at 86°F (30°C), no condensation]
Storage Temperature 40°F to 194°F (-40°C to +90°C)
Storage RH Range 10 - 90% (Tested at 30°C, no condensation)
MTD - >4μ(c), >6μ(c), >14μ(c), >21μ(c), >38μ(c), >70μ(c), ACFTD - >2μ, >5μ, >15μ,
Channel Sizes
>25μ, >50μ, >100μ
Analysis Range ISO 7 to 21, NAS 0 to 12
MTD - ISO 4406:1999 & NAS 1638 ACFTD - ISO 4406:1987, ISO 4406:1991, NAS
Contamination Standards 1638, and AS4059 Rev E
For further contamination standards consult Parker
ISO MTD and ACFTD calibration to traceable ISO Standards. (Contact Parker for
Calibration Standard
further details)
Fluid Management Maximum single sample = 100ml, Minimum single sample = 10ml
User selectable from single test up to 5 tests per run (eg. 1 x 100ml up to 5 x 50ml
Possible Test Configurations
per run)
Pre-Test Flush Volume Minimum = 10ml, Maximum = 100ml
Viscosity Range 5 to 400 cSt
Mineral oils, petroleum and hydrocarbon based fluids. For all other fluids, consult
Fluid Compatibility
factory.
No specific bottle required. Maximum size = 2.95” (Dia.) x 5.90” (H). Maximum
Sample Bottle Size
volume = 250ml
Memory Storage 500 tests (capacity warning after 450 tests)
Output Display Backlight 256 color STN transmissive
Output Display Resolution 320 x 3 (RGB) (H) x 240 (W) dots
Display Active Area 115 (H) x 86 (W) mm
Data Input Via icon driven resistive touch screen
Printer Thermal dot-line printing
Printer Paper Ø50mm - (57mm x 25mm)
Test Certification Calibration & Certificate of Conformity
DC output - 12V @ 6.60Amps, 80 watts max. AC input - 100 to 240V @ 1.2Amps (50
Power Supply
- 60 Hz)
Battery Power 2 hours (recommended to be fully charged every 3 months)
Battery Stand-By Time 1 month (then 1 hour of operation)
Battery Fuse 6.3 Amps (anti-surge)
Air Pressure Source 50 psi (3.5 bar) internal mini-compressor or 101 psi (7 bar) shop air
21
icountBS - Bottle Sampler Ordering
Information
Part Number
IBS3000 (offline/online)
IBS3100 (offline only)
Accessories Part Number Included
250ml Sample Bottle (2 per pk) ACC6NW001 * (1 pk)
Sample Bottle Pack (50) ACC6NW002 (2 pks of 50)
Vapour/Waste Bottle ACC6NW003 *
Waste Bottle Folder ACC6NW004
Printer Paper Reel (x1) ACC6NW005 *
Transport Case P893865 *
1m Waste Tube (Clear) ACC6NW009 *
1m Vapour Hose (Blue) ACC6NW010 *
USB Memory Stick ACC6NW011 *
icountBS CD Manual ACC6NW012 *
Air Connector P.893318 *
* These items included with IBS unit within a transportation case.
22