AIR & GAS FILTRATION, SEPARATION SOLUTIONS
GENERAL CATALOGUE
WHY CHOOSE
COMPAC ADSORPTION AIR
DRYERS
Compressed Air
Refrigeration Dryer Heatless Desiccant Dryers
COMPAC 900 - 120.000 Blower Purge Desiccant / Zero
Series Purge Cooling
04/09 10/17
BLOWER PURGE AIR FILTER
DESICCANT
DRYERS AF Series Compressed
Air Filters
Zero Purge Cooling
18/21 22/27
OIL MIST ACT ACTIVATED CARBON
ELIMINATORS TOWER
Oil Mist Separation Oil Molecule and Odor
Retention Filters
28/33 34/35
WATER ZEROMAT
SEPARATORS
Timed Drain
Manual / Mini Ballcock Waiting / Systems
Discharge Time Setting Adjusted
/ Zero Air Loss
36/37 38/39
LASER AIR LASER COMBINED AIR
DRYER DRYER
Quality Compressed Air Combined Pressure Air Dryer for
for Plasma Systems Laser Cutting Machines
40/41 42/43
2 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
BATTAL SERIES NITROGEN GENERATOR
PRESSURIZED AIR DRYER MINI MODEL
Water cooled air dryers for Advanced System in Gas
capacities higher than Separation
120 m3/min Nitrogen Production Unit
44/45 46/47
MODULAR NITROGEN NITROGEN GENERATOR
GENERATOR TWINTOWER MODEL
Advanced System in Gas Advanced System in Gas
Separation Separation
Nitrogen Production Unit Nitrogen Production Unit
48/53 54/59
MEMBRANE NITROGEN OXYGEN GENERATOR
GENERATORS MINI MODEL
Advanced System in Gas Advanced System in Gas
Separation Separation
Nitrogen Production Uni Oxygen Production Unit
60/67 68/69
MODULAR OXYGEN OXYGEN GENERATOR
GENERATOR TWINTOWER MODEL
Advanced System in Gas Advanced System in Gas
Separation Separation
Oxygen Production Unit Oxygen Production Unit
70/75 76/79
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
3
COMPAC A
COMPAC AIR DRYER
Compressed Air Refrigeration Dryer
COMPAC 900 - 120.000 Series
AIR DRYER HIGH EFFICIENCY HEAT EXCHANGER DESIGN
A design which has no welded parts with the feature of easy assembly and
disassembly. It uses ambient temperature for pre-refrigeration of incoming
hot air. Efficient heat transfer with aluminium panel fins, a design which is
not affected by the problems which arise from freezing at low temperatures.
INTELLIGENT CONTROL SYSTEM
•Display of pressure dew point through a clear scale
•Sound and light alarm output for problems in the
compressed air refrigeration dryer
•Quick identification of the affected component
•Trouble-shooting overview in the manual enables a
direct debugging in most cases
•Manual condensate discharge by pressing the on /
off button twice
•Integrated signal output for external alarm
(12 V DC signal)
DURABLE RIGHT DESIGN
and COPPER PIPING
A stable and excellent vibration free refrigeration system.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
5
SIMPLE BY-PASS LINE WITH INLET and OUTLET FILTERS
Inlet and outlet filters and heat exchanger on the same line up till C-8500 model.
*Outlet pressurized air quality
ISO 8573-1; 2010
Oil Class :1............ 0,01 mg / m3
Dust Class :1............ 0,1 micron
Water Class :4........... 6 gram / m3
VARIOUS HARDWARE SMALL SIZE 1 2 3 4 5 5 3 2
1- Water Seperator
2- Inlet Filter 1 micron dust, 0,5mg / m3 oil
3- Heat Exchanger Water concent: 6mg / m3
4- Active Carbon Tower Oil 0,003mg / m3
5- Outlet Filter 0,1 micron dust
6- Zeromat Zero air loss water drain
IMPRESSIVE DESIGN and
INNOVATION
COMPAC: Premium features and economical price
6 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
DESIGNED FOR TROPICAL CONDITIONS
INLET TEMPERATURE °C PRESSURE DEW-POINT (7 BAR G) WATER CONCENT
+35 °C +3 °C 5,9 gram / m3
+60 °C +12 °C 10,6 gram / m3
LOW PRESSURE DROP WITH DESIGN OPTIONS
» Pressure Drop T. max. = 0,1 ~ 0,2 bar (g) (at 3 °C Pressure Dewpoint)
» COMPAC.....0 Series Standard Design
» COMPAC.....1 Series Cold Air Outlet (+3 °C) Design. (for treatment before a
N2 /O2 generator)
» COMPAC.....2 Series High Inlet Temperature (+70 °C) Design
» COMPAC.....3 Series High Operating Pressures 50 bar (g)
PRODUCTION NORMS & METHODS
2006/42/EC Machine Safety Directive
2014/30/EU Electromagnetic Compatibility Directive
2014/35/EU Low Voltage Directive
EN ISO 12100 2010
EN 60204-1 2006+A1:2009/AC:2010
EN 61000-6-2 2005/AC:2005
EN 61000-6-4 2007/A1:2011
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
7
COMPAC COMPRESSED AIR DRYER TECHNICAL DATA
OUR MODELS CAN BE PREPARED TO BE OPERATED AT FREQUENCIES OF 50Hz AND 60Hz DEPENDING ON YOUR REQUIREMENTS
THEREFORE CAN BE USED IN MARINE APPLICATIONS.
COOLER FLUID TYPES CAN BE CHANGED WHEN NECESSARY (R407c - R404a)
Models between Compac 900 and 6.500 Models between Compac 8.500 and 20.000 Models between Compac 25.500 and 120.000
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
8 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
CORRECTION FACTORS
CORRECTION FACTORS FOR DIFFERENT OPERATING PRESSURES
BAR 5 6 7 8 9 10 11 12 13 14 15 16
FE:1 0,9 0,96 1,0 1,04 1,06 1,09 1,10 1,20 1,24 1,31 1,39 1,48
CORRECTION FACTORS FOR DIFFERENT AMBIENT TEMPERATURES
˚C 20 25 30 35 40 45 50
FOS:1 1,05 1,0 0,98 0,93 0,84 0,76 0,7
CORRECTION FACTORS FOR DIFFERENT INLET AIR TEMPERATURES
˚C 30 35 40 45 50 55 60
AG:1 1,29 1,0 0,92 0,78 0,65 0,65 0,45
CORRECTION FACTORS FOR DIFFERENT DEWPOINT TEMPERATURES
˚C 2 3 6 8 10
FÇİ:1 0,8 1,0 1,14 1,25 1,36
REFERENCE CONDITIONS LIMIT CONDITIONS
Operating Pressure : 7 bar (100psi) Max. Operating Pressure : 16 bar (232psi)
Operating Temperature : 35°C / 95°F Max. Operating Temperature : 60°C / 140°F
Room Temperature : 25°C / 77°F Min. Room Temperature : +5°C / 41°F
Pressure Dewpoint :+3°C + / -1 / 37,4°F Max. Room Temperature : +50°C / 122°F
*Available in different voltages and frequency *Please Check Correction Factors
FORMULA
NOMINAL FLOW RATE
REAL FLOW RATE:
FE x FOS x AG x FÇİ
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
9
ADSORPTION
ADSORPTION AIR DRYERS
Heatless Desiccant Dryers / Blower
Purge Desiccant / Zero Purge Cooling
NAIR DRYER CNK DEW POINT CONTROLER
Controls the dew point of compressed air. CNK automatically organizes the flow of
compressed air in the towers before dewpoint reaches to higher values than the set dew
point. Therefore the outlet dewpoint of compressed air gets down to a lower value.
CNK prevents compressed air loss by extending operation time depending on dewpoint.
CNK provides cost savings up to 75% by organizing operation times of towers depending
on dewpoint.
Alarm function warns when necessary.
CNK is used as accessories in AK-DAB and AK-DAC systems and comes readily available.
AK-DAB; AK-DAC ADSORPTION DRYER
Two towers are filled with adsorbant materials. They are designed to filter H20 molecules
by sieving. H20 molecules which adhere to the surface of adsorbent material can be easily
separated by the interaction of molecular forces from where they are hold. While the first
tower dries the incoming air, the second tower is regenerated with the reverse-direction
regenerative air. This is a physical reaction and can be repeated countless times
This operation is alternated between two towers at normally 10 min intervals. Process goes
in the order of drying, balancing and regenerating. The amount of air used for regeneration
is approximately 15% for AK-DAB model, 30% for AK-DAC model and 15% for AK-DAB-20C.
Besides, during the balancing operation the air in one tower is discharged.
Absorbent material is designed for these kinds of applications. When the system is
protected from contamination from compressor oil (which is at levels less than 0,001 mg/
m3) of protection, replacement is suggested after a period of 5 years.
OPERATION
With the help of these applications, it is possible to reach -40˚C (0.117 gr/m3) pressure
dew-point with the model AK-DAB and -70˚C (0.0033 gr/m3) pressure dew-point with
the model AK-DAC, -20˚C (0,88 gr/m3) pressure dew-point with the model AK-DAB-20C.
STANDARD ACCESSORIES
Electronic controller, at inlet; water separator with zero loss, oil alarm sensor, 1 micron dust
and 0.5 mg/m3 oil at outlet filter, 0,1 micron dust filter, 0,01 mg/m3 oil filter.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
11
ADSORPTION AIR DRYER TECHNICAL DATA
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
12 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
ADSORPTION AIR DRYER TECHNICAL DATA
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
13
ADSORPTION AIR DRYER TECHNICAL DATA
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
14 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
CORRECTION FACTORS
CORRECTION FACTORS FOR DIFFERENT OPERATING PRESSURES
BAR 4 5 6 7 8 9 10 11 12 13
Fc:T 0,60 0,74 0,86 1 1,10 1,20 1,30 1,35 1,40 1,46
CORRECTION FACTORS FOR INLET TEMPERATURE OPERATING PRESSURES
˚C 25 30 35 40 45 50
Fc:T 1,10 1,05 1 0,9 0,70 0,60
REFERENCE CONDITIONS LIMIT CONDITIONS
Operating Pressure : 7 bar Max. Operating Pressure : 16 bar
Operating Temperature : 35°C Max. Operating Temperature : 50°C
Room Temperature : 25°C Max. Room Temperature : 50°C
Pressure Dewpoint :-20°C / -40°C / -70°C *Please Check Correction Factors
*Available in different voltages and frequency
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
15
DRY AIR CUTTING SYSTEM 40 BAR (g)
DRY AIR CUTTING SYSTEM 13 BAR (g)
16 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
DRY AIR CUTTING SYSTEM 40 BAR (g) DRY AIR CUTTING SYSTEM 40 BAR (g)
DRY AIR CUTTING SYSTEM 13 BAR (g)
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
17
DESICCAN
BLOWER PURGE
DESICCANT DRYERS
Zero Purge Cooling
-40°C/-70°C
NT DRYERS
AK-DAB / AK-DAC 6001 - 160001
This type of dryers have been designed to produce compressed dry air at dew points higher than -40°C and
-70°C and operate with an air loss at a rate of 2%.
That air loss can be reduced to minimal levels depending on a dew point controller addition.
This operation is achievable by producing tower regeneration air by a blower and resistance heater.
AK-DAB / AK-DAC 20002 - 160002
This type of dryers have been designed to produce compressed dry air at dew points higher than -40°C and
-70°C and deliver dried compressed air without any loss to a plant’s operating systems.
This operation is achievable by producing regeneration air by a blower and resistance heater and cooler.
THE VIEW FROM THE TOP LCD TOUCH SCREEN CONTROL PANEL
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
19
BLOWER PURGE DESICCANT DRYERS TECHNICAL DATA
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
20 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
CORRECTION FACTORS
CORRECTION FACTORS FOR DIFFERENT OPERATING PRESSURES
BAR 4 5 6 7 8 9 10
Fc:T 0,60 0,74 0,86 1,00 1,10 1,20 1,30
CORRECTION FACTORS FOR INLET TEMPERATURE OPERATING PRESSURES
˚C 25 30 35 40 45 50
Fc:T 1,10 1,05 1,00 0,90 0,70 0,60
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
FOR BIGGER CAPACITIES AND MODELS, PLEASE CONTACT WITH OUR TEAM
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
21
COMPRESSED
COMPRESSED AIR FILTERS
Compressed Air, Oil and Water
Retention Filters
DAIR FILTERS
WHY SHOULD PRESSURIZED AIR BE FILTERED?
There are about 140 million granules of dust and similar particles in 1 m3 of
typical city air. 90% of these granules are under 2 microns. These granules
(about 5 microns) pass from suction filter of your compressor easily, enter
the compressor unit and spread with pressurized air into air assembly. On the
other hand, at least 6 mg/m3 burned oil comes from the compressor which
is combined with water and dust in the air and damages o-rings, felts of all
equipment working with pressurized air. It causes air leakages, oxidation and
blockage of valves. Furthermore, it damages the quality in coating systems.
Therefore, filtration of pressurized air is very important in industry. Filters are
produced in three separate sensitivity levels and are connected sequentially
according to the importance of their placement. Depending on the Daily
operation time, ambient temperature and the compressors oil discharge
rate, filter components should be replaced after 4 to 6 months of use. Filter
components can not be cleaned; blocked components should be replaced
immediately.
PRESSURIZED AIR QUALITY:
MEASUREMENTS and APPLICATIONS
DIN ISO 8573-1 form compressed air quality is separated into classes according to above factors.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
23
ACCESSORIES
DIFFERENTIAL PRESS. TIMED DRAIN
INDICATOR Timed drain with waiting and
When internal element of discharging time setting.
your filter is polluted, indicator
turns from green to red.
Furthermore, it is possible to
receive electronic signal.
OTA-02 TIMED DRAIN ZEROMAT
Automatic mini Zero compressed air loss drain
floatcondensate drain. with magnetic smart sensor.
A
C
YAF - 1.6000 SA - 1.200 AFİ - 5.500 AF - 18.000 AF - 70.000
High Pressure Water Filter Compressed Compressed
Compressed Air Filter Seperator Element Air Filter Air Filter
24 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
In the input filter; particle up to 1 micron and air filtration up to 0,5 ppm (0,5 mg/m3) are provided
In the active carbon filter; air and odour filtration up to 0,003 ppm (0,003 mg/m3) is provided
Recommended internal element change pressure difference 700 Mbar.
In the active carbonized filter; air and odour filtration up to 0,003 ppm (0,003 mg/m3) is provided
In the output filter; particle up to 0,01 micron and air filtration up to 0,01 ppm (0,01 mg/m3) are provided
Starting pressure loss 80-120 Mbar.
Technical Specifications are offered for 21 °C.
With the given flow rates, Operating Pressure is 7 bar (g)
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
25
COMPRESSED AIR FILTERS TECHNICAL DATA
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
26 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
COMPRESSED AIR FILTERS TECHNICAL DATA
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
27
OIL MIST EL
OIL MIST ELIMINATORS
Oil Mist Separation
LIMINATORS
OIL MIST ELIMINATORS
AREAS OF USE
Applications which require oil-less air
Oil mist separators which are located after oil compressors,
vacuum pumps and fan blowers
Systems which require high air flow but low pressure drop
Vacuum freezing applications
Processes where gas is taken out by vacuum
Vacuum coating applications
Food processing plants
Nailing / stapling machines
Industrial vacuum applications
Cement and paper plants
DESIGN
Oil mist eliminators are designed for these requirements
Separation of oil mist from piston or screw compressors
Long service time and resistance against hard working conditions
Protection of the system against oil mist in case compressor oil
separator is malfunctioning
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
29
PROPERTIES
Low pressure drop
High oil retention capacity
Easy cleaning and maintenance
Full impermeability with O-rings
Automatic drainage
Alternative drainage types
Maximum operating pressures
Wide temperature range (min 4°C (40°F), max 80°C (176°F)
Grounded elements to prevent static
Particle retention up to 0,01 micron and decrease of oil content down to 10 ppm
Slow and effective separation at specified flowrates by enlarged surface area and therefore
elimination of oil mist.
OIL MIST SEPARATOR ELEMENT
Long service life
Energy savings due to very low pressure drop
Pressure difference for filter change 2.5 psig (170 mbar)
Thorough separation of air and oil
High quality seals for efficient filter operation
30 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
TECHNICAL PROPERTIES
SAMPLE AIR LINE FOR OIL-FREE COMPRESSORS DEW POINT
ACTIVE CARBON
TOWER
OIL MIST
ELIMINATOR
AIR PRESSURIZED
DRYER AIR FILTER
WATER
SEPARATOR
OIL FREE BUFFER
COMPRESSOR TANK
DEW POINT
ACTIVE CARBON
TOWER
PRESSURIZED
AIR FILTER
DESICCANT
DRYER
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
31
OIL MIST ELIMINATORS TECHNICAL PROPERTIES
CORRECTION FACTORS
To find the most suitable model with high
efficiency, multiply the flowrate from
the table above with the corresponding
correction factor on the left.
FİRMAMIZ KATALOGDAKİ DEĞERLERİ ARAŞTIRMA, GELİŞTİRME ÇALIŞMALARINA GÖRE PARALEL OLARAK DEĞİŞTİREBİLİR.
32 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
33
CARBON
ACT ACTIVATED
CARBON TOWER
Oil Burner and Odor Holder
Filters
N TOWER ACT ACTIVATED CARBON TOWER
It works on the basis of absorption of oil vapor and hydrocarbon odors by absorbent material. Even if the adsorbent
material takes the oil vapor quantity down to very low levels, after saturation, it doesn’t continue to filtrate.
OPERATION
ACT Activated Carbon Tower absorbs oil vapour and hydrocarbon odour in compressed air around 0.003 mg/m3,
if the inlet compressed air temperature is 20˚C. Compressed Air Quality: ISO 8573 Class 1 (oil)
APPLICATIONS
• When faced with high oil vapour input • Protection of absorbant • When oil vapour and hydrocarbon
material odour affects products.
i.e : high pressure piston Compressor.
i.e : Adsorption dryer
TECHNICAL SPECIFICATIONS
Pressure loss: 200 mbar (0.2 bar)
Service life max: ~12 months (8000 hour) 30˚C (86˚F)
~3 months (2000 hour) 45˚C (113˚F)
∆P: 200 mbar.
Working Pressure Max.: 16 bar
Inlet Temperature: 20˚C
Oil Concentration 0,003 mg/m3
Service Life Max. ~12 months (8000 hour) 30˚C
~3 months (3000 hour) 45˚C
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
35
WATER SEP
WATER SEPARATORS
Manual / Mini Ballcock / Waiting / Discharge
Time Adjusted / Zero Air Loss
PARATORS AF 4 SERIES WATER SEPARATORS
In compressed air systems, liquid water that is formed from cooling and pressure effects, proceed in compressed
air line as droplets. If precautions are not taken, it causes serious problems such as rusting in pneumatic systems,
air leakages and valve jams.
In order to avoid problems like these, compressed air and liquid water should be separated from each other with
the AF-04 series water separators.
OPERATION
OTA-01 TIMED DRAIN
Timed drain with adjustable waiting and discharging times
OTA-02 TIMED DRAIN
Automatic mini float condensate drain.
ZEROMAT
Smart magnetic sensor auto drain with zero compressed air loss.
AF 4 SERIES WATER SEPARATORS TECHNICAL DATA
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
37
ZEROMAT
ZEROMAT
Timed Drain Systems
T TIMED DRAIN SYSTEM
In compressed air systems, liquid water that is formed from cooling and pressure effects is much more in summer
than in winter.
By a water separator, compressed air and liquid water are separated from each other. That liquid water can be
discharged by the following
Three options:
1-) Employee in charge manually opening and closing the drain valve periodically. (Because a personnel has to
engage with it and compressed air will be discharged with water, it's not recommended)
2-) A. Consists of waiting and discharging time adjusted timer + solenoid valve + filtered faucet; by Ota-
01 discharger with air loss. (compressed air is discharged with water periodically. Seasonal (summer/winter)
adjustment will be necessary)
B. Mini float condensate drain: It’s an unprofessional type of drain (it can clog earlier, become functionless)
3-) With Zeromat, it becomes possible to discharge the water without air loss and there is no need for seasonal
adjustment.
It's a professional piece of equipment. It's not affected from the pollution with the help of dust filters inside it. It
saves energy because of zero air loss. So in a short time, you can amortize its cost. Automatic drain systems are
placed under the air receivers & AF series compressed air filters & AF-04 series water separators. It is chosen
according to the requirements of the compressed air system and discharge the liquid water without air loss.
ZEROMAT TIMED DRAIN SYSTEMS TECHNICAL DATA
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
39
LASER AI
LASER AIR DRYER
Quality Compressed Air for
Laser/Plasma Systems
40 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
IR DRYER
LASER AIR DRYER TECHNICAL DATA
Max. Working Pressure
Pressure Dew Point
: 16 bar (g)
: +3°C
Atmospheric Dew Point : -22°C
Airborne Water Pressure : 6 gram / m3 / 7 bar (g)
Compressed Air Remaining Oil : 0,003 gram / m3
Compressed Air Remaining Dust : 0,01 micron
Compressed Air Quality
Zero Air - Loss Drain
: ISO 8573-1: 0-1-4
YEAR WORKING LIFE
SOLUTIONS
OPERATION
Optics and other pneumatic equipment of your laser cutting machines is under
our guarantee.
OPERATION
Supplies your laser cutting machines with quality and clean pressurized air,
also automatically stops air flow with its emergency valve.
PERIODIC MAINTENANCE
Need to change 2 Air filter cartridges every 6 months and active carbon every
2 years.
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
41
LASER CO
LASER COMBINED
AIR DRYER
Combined Pressure Air Dryer for
Laser Cutting Machines
42 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
OMBINED
COMBINED LASER AIR DRYER TECHNICAL DATA
Max. Working Pressure
Pressure Dew Point
: 16 bar (g)
: -70°C
Atmospheric Dew Point : -83°C
Airborne Water Pressure : 0,0033 gram / m3 / 7 bar (g)
Compressed Air Remaining Oil : 0,003 gram / m3
Compressed Air Remaining Dust : 0,001 micron
Zero Air - Loss Drain
YEAR WORKING LIFE
SOLUTIONS
OPERATION
Cutting air supply : ISO 8573-1 : 0-1-1
Precise cut of stainless steel up to 2 mm [ 13 bar (g) ]
OPERATION
Quality pressurized air supply for laser cutting machine
PERIODIC MAINTENANCE
Need to change 3 air filter cartridges every 6 months, active carbon each year
and desiccant dryer filling material every 5 years.
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
43
BATTAL SERIES
BATTAL SERIES
PRESSURIZED AIR DRYER
Water cooled air dryers for
capacities higher than 120m3/min
S PRESSURIZED
WATER COOLING HIGH-TEMPERATURE TYPE
TECHNICAL DATA
Inlet Temperature : ≤80°C
Cooling Water Temperature : ≤32°C
Cooling Water Pressure : 0.2MPa - 0.5MPa
Rated Pressure : 0.6MPa ˜ 0.95MPa
Pressure Dew Point : 2 ˜ 10°C
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
45
NITROGEN
NITROGEN GENERATOR
MINI MODEL
Advanced System in Gas Separation
Nitrogen Production Unit
N
MINI MODEL NITROGEN GENERATORS TECHNICAL DATA
MINIMUM NITROGEN OUTPUT FLOW WITH COMPRESSED AIR INLET
PRESSURE OF 7,5 BAR (g)
OUR COMPANY CAN OPTIONALLY INSTALL A NITROGEN LIQUEFYING UNIT TO THESE MODELS
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
FOR BIGGER CAPACITIES AND MODELS, PLEASE CONTACT WITH OUR TEAM
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
47
MODULAR
MODULAR NITROGEN
GENERATOR
Advanced System in Gas Separation
Nitrogen Production Unit
Rev. No: 017 Rev. Date: 20.11.2019
NITROGEN
ADVANTAGES OF THE MODULAR NITROGEN GENERATOR
Produces high-purity nitrogen gas from compressed air (purity up to 99,999%).
Due to its modular design (international patents pending);
Creates the most appropriate solution to any capacity of required nitrogen gas.
Modular design offers you ideal and economical opportunities as nitrogen consumption increases.
Simply adjust your NITROPAK system by varying the number of PSA modules by yourself, no other adjustment
or additional component is required.
Modular design: Decreases energy costs due to ideal capacity utilization, that provides real savings to you.
If we express another way, the capacity value does not fall swiftly while purity value increases like in the twin
tower design.
PSA modules are made from eloxal coated aluminum fins and aluminum cast heads with electrostatic heat
coatings; this coupled with their ease of assembly and disassembly, a resistant PLC screen and good valves,
they can operate for long periods of time.
Inlet pressure of pressured air: 7,5bar(g), Nitrogen outlet pressure: 6,5bar(g)
Inlet pressure of pressured air: 10bar(g), Nitrogen outlet pressure: 8bar(g)
Inlet pressure of pressured air: 11,5bar(g), Nitrogen outlet pressure: 10,5 bar(g)
Modular design offers you a compact construction; Ideal for container solutions with this size constancy.
The spare parts are the same in the all models where identical components are used for the entire model range.
This means, limited spare part management, easy maintenance and services.
Same desiccant material and bead diameter use for all models.
Modular NITROPAK is limited with a total of 8 pairs of modules. It possible to operate a total of 3 Modular
NITROPAK systems with 8 module pairs with the same PLC and Nitrogen Analyzer.
WHAT IS PSA TECHNOLOGY?
Nitrogen generators consist of colons full of CMS (Carbon Molecular Sieve) Material. Under pressure, these colons
hold all the materials except Argon noble gas in the air. During pressure application, Oxygen, CO2 and water
molecules attach to molecular sieve material. This process is known as pressure swing adsorption (PSA).
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
49
STANDARD EQUIPMENT
Water separator for inlet of pressurized air, 1 unit
Water discharge system with zero air loss, 1 unit (Zeromat)
Line filters to for feeding pressure air, 2 units (0,5 and 0,01 mg/m3)
Output filter, 0.01 mg/m3, 1 pcs
Pneumatic valves
PLC control system with fully automatic operations
Pressure switch for automated Idle-Mode
Sensor for inlet of feed compressed air quality
Exhaust mufflers
Regulator for nitrogen pressure
FIELDS OF APPLICATION
Nitrogen gas is used in a variety of industrial It is stored or produced on-site to supress other
applications. unwanted gases such as Oxygen in various processes.
FOOD, MEDICINE, PACKAGING, AVIATION , AUTOMOTIVES, LASER CUTTING, ELECTRONICS, PETROCHEMICALS,
PLASTIC INJECTIONS, COOLING, CHEMICAL, COATING, COSMETICS industries are the main sectors.
50 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
LCD TOUCH DISPLAY CONTROL PANEL PROPERTIES
Total work time display
Automatic or manual operation
Measurement of gas purity constantly or instantly (Optional 30 days purity memory)
Adjustable time settings
Language (Turkish-English-Spanish)
One touch technical service contact details
Optional alarm with sound or light on demand
Automatic stop control when outlet pressure increases
DRY AIR COMPOSITION
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
51
MODULAR NITROGEN GENERATORS TECHNICAL DATA
MINIMUM NITROGEN OUTPUT FLOW WITH COMPRESSED AIR INLET
PRESSURE OF 7,5 BAR (g)
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
52 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
CORRECTION FACTORS
PRESSURE INLET BAR (psi) FOR 7,5 BAR (g) INLET
6,5 7,5 8,5 9,5 10,5 11,5
COMPRESSED AIR INLET PRESSURE (94,3) (108,8) (123,3) (137,8) (152,3) (181,3)
PERFORMANCE PERCENTAGE 0,84 1 1,08 1,16 1,25 1,3
COMPRESSED AIR INLET TEMPERATURE IN °C (°F)
5 10 15 20 25 30 35 40 45 50
(41) (50) (59) (68) (77) (86) (95) (104) (113) (112)
0,85 1,03 1,02 1 0,93 0,86 0,8 0,72 0,6 0,52
REFERENCE CONDITIONS 2
Ambient Temperature Working Range : +5 / +40˚C (41˚F / 104˚F)
Minimum Air Inlet Pressure : 6,5 bar (g) (94,3 psi)
Maximum Air Inlet Pressure : 11,5 bar (g) (181,3 psi)
Please Check Correction Factor
Compressed Air Inlet Quality: ISO 8573-1
1. Quality 1-1-2 or
1. Quality 1-1-4
Electrical Power Supply : 110 / 230V, 50/60Hz
1 WITH A TOLARANCE OF ±5% 2 CHECK REFERENCE CONDITIONS 3 PLEASE CONTACT CUSTOMER SERVICE AND/OR REPRESENTATIVE FOR ADVICE
OUR COMPANY CAN OPTIONALLY INSTALL A NITROGEN LIQUEFYING UNIT TO THESE MODELS
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
FOR BIGGER CAPACITIES AND MODELS, PLEASE CONTACT WITH OUR TEAM
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
53
NITROGENG
NITROGEN GENERATOR
TWINTOWER MODEL
Advanced System in Gas Separation
Nitrogen Production Unit
54 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
GENERATOR ADVANTAGES OF THE NITROGEN GENERATOR
Reliable and economical N2 production with PSA technology up to 99,999% purity
Amortizes costs in less than 2 years time.
The spare parts are in our stock because same components are used in all models. Periodic maintenance
is only once in every 6 months and economical.
It eliminates logistical or supplier problem which arise from the transportation of liquid or cylinder
nitrogen.
AAG Nitrogen Generator unit was designed to swiftly amortize your investments by helping you save
substantially on nitrogen consumption.
STANDARD EQUIPMENT
Water separator for inlet of feed pressure air, 1 unit
Water discharge system with zero air loss, 1 unit (Zeromat)
Line filters for feeding pressurized air, 2 units (0,5 and 0,01 mg/m3)
Outlet filter, 1 pc, 0.01 mg/m3
Pneumatic valves
PLC control system with fully automated operations
Pressure switch for automated Idle-Mode
Sensor for compressed air inlet
Exhaust mufflers
Regulator for nitrogen pressure
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
55
LCD TOUCH DISPLAY CONTROL PANEL PROPERTIES
Total work time display
Automatic or manual operation
Measurement of gas purity constantly or instantly (Optional 30 days purity memory)
Adjustable time settings
Language (Turkish-English-Spanish)
One touch technical service contact details
Optional alarm with sound or light on demand
Automatic stop control when outlet pressure increases
DRY AIR COMPOSITION
56 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
FIELDS OF APPLICATION
Nitrogen gas is used in a variety of industrial It is stored or produced on-site to supress other
applications. unwanted gases such as Oxygen in various processes.
FOOD, MEDICINE, PACKAGING,AVIATION, AUTOMOTIVES, LASER CUTTING, ELECTRONICS, PETROCHEMICALS,
PLASTIC INJECTIONS, COOLING, CHEMICAL, COATING, COSMETICS industries are the main sectors.
(1) Please contact us for higher nitrogen pressure NITROGEN BOOSTER COMPRESSOR
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
57
TWINTOWER MODEL NITROGEN GENERATORS TECHNICAL DATA
MINIMUM NITROGEN OUTPUT FLOW WITH COMPRESSED AIR INLET
PRESSURE OF 7,5 BAR (g)
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
58 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
CORRECTION FACTORS
PRESSURE INLET BAR (psi) FOR 7,5 BAR (g) INLET
6,5 7,5 8,5 9,5 10,5 11,5
COMPRESSED AIR INLET PRESSURE (94,3) (108,8) (123,3) (137,8) (152,3) (181,3)
PERFORMANCE PERCENTAGE 0,84 1 1,08 1,16 1,25 1,3
COMPRESSED AIR INLET TEMPERATURE IN °C (°F)
5 10 15 20 25 30 35 40 45 50
(41) (50) (59) (68) (77) (86) (95) (104) (113) (112)
0,85 1,03 1,02 1 0,93 0,86 0,8 0,72 0,6 0,52
REFERENCE CONDITIONS 2
Ambient Temperature Working Range : +5 / +40˚C (41˚F / 104˚F)
Minimum Air Inlet Pressure : 6,5 bar (g) (94,3 psi)
Maximum Air Inlet Pressure : 11,5 bar (g) (181,3 psi)
Please Check Correction Factor
Compressed Air Inlet Quality: ISO 8573-1
1. Quality 1-1-2 or
1. Quality 1-1-4
Electrical Power Supply : 110 / 230V, 50/60Hz
1 WITH A TOLARANCE OF ±5% 2 CHECK REFERENCE CONDITIONS 3 PLEASE CONTACT CUSTOMER SERVICE AND/OR REPRESENTATIVE FOR ADVICE
OUR COMPANY CAN OPTIONALLY INSTALL A NITROGEN LIQUEFYING UNIT TO THESE MODELS
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
FOR BIGGER CAPACITIES AND MODELS, PLEASE CONTACT WITH OUR TEAM
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
59
MEMBRAN
MEMBRANE NITROGEN
GENERATORS
Advanced System in Gas Separation
Nitrogen Production Unit
60 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
NE NITROG
Nautical and naval applications
Drilling Vessels
Open Seas
Chemical Haulers
AREAS OF USE
FPSO LNG / LPG
ADVANTAGES
Minimum of 60% decrease in costs for 10 years 50% less space Purity 95-99,9%
Easy to assemble, operate and maintain Production in Euro standards Custom design
Dry nitrogen with -70°C PDP Assembly at hazardous areas Durable stainless steel or
aluminium body
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
61
ISO 8573-1 – TOTAL OIL & PARTICLES
COMPRESSED AIR PURITY CLASSES FOR PARTICLES
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
62 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
ISO 8573-1 – TOTAL OIL & PARTICLES
COMPRESSED AIR PURITY CLASSES FOR TOTAL OIL
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
63
EFFICIENCY ZONES FOR PSA, MEMBRANE AND
CRYOGENIC PLANTS
64 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
FLOW CHART
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
65
PROJECTS
66 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
PROJECTS
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
67
OXYGEN
OXYGEN GENERATOR
MINI MODEL
Advanced System in Gas Separation
Oxygen Production Unit
68 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
N
MINI MODEL OXYGEN GENERATORS TECHNICAL DATA
MINIMUM OXYGEN OUTPUT FLOW WITH COMPRESSED AIR INLET
PRESSURE OF 7,5 BAR (g)
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
FOR BIGGER CAPACITIES AND MODELS, PLEASE CONTACT WITH OUR TEAM
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
69
MODULAR
MODULAR OXYGEN
GENERATOR
Advanced System in Gas Separation
Oxygen Production Unit
R OXYGEN
ADVANTAGES OF THE AAG OXYGEN GENERATOR
Produces high-purity oxygen gas from compressed air (purity up to 93±3%).
Due to its modular design (international patents pending);
Creates the most appropriate solution to any capacity of required oxygen gas.
Modular design offers you ideal and economical opportunities as oxygen consumption increases.
Simply adjust your OKSIPAK system by varying the number of PSA modules by yourself, no other adjustment
or additional component is required.
Modular design: Decreases energy costs due to ideal capacity utilization, which provides real savings to you.
If we express another way, the capacity value does not fall swiftly while purity value increases like in the twin
tower design.
PSA modules are made from eloxal coated aluminum fins and aluminum cast heads with electrostatic heat
coatings; this coupled with their ease of assembly and disassembly, a resistant PLC screen and good valves,
they can operate for long periods of time.
Inlet pressure of pressured air: 7,5bar(g), Nitrogen outlet pressure: 6,5bar(g)
Inlet pressure of pressured air: 10bar(g), Nitrogen outlet pressure: 8bar(g)
Inlet pressure of pressured air: 11,5bar(g), Nitrogen outlet pressure: 10,5 bar(g)
Modular design offers you a compact construction; Ideal for container solutions with this size constancy.
The spare parts are the same in the all models where identical components are used for the entire model range.
This means, limited spare part management, easy maintenance and services.
Same desiccant material and bead diameter use for all models.
Modular OKSIPAK is limited with a total of 8 pairs of modules. It possible to operate a total of 3 Modular
OKSIPAK systems with 8 module pairs with the same PLC and Oxygen Analyzer.
WHAT IS PSA TECHNOLOGY?
Oxygen generators consist of colons full of CMS (Carbon Molecular Sieve) Material. Under pressure, these colons
hold all the materials except Oxgyen and Argon noble gas in the air. During pressure application, Nitrogen, CO2
and water molecules attach to molecular sieve material. This process is known as pressure swing adsorption
(PSA).
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
71
FIELDS OF APPLICATION
Oxygen gas is used in a variety of industrial applications.
HOSPITALS, LABORATORIES, OXYFUEL TECHNOLOGY, WELDING, BRAZING AND STEEL CUTTING, FISH
FARMING, OZONE, WASTE WATER TREATMENT industries are the main sectors.
STANDARD EQUIPMENT
Food pack filter kit Medical kit Remote GSM control PC Access with ethernet connection
650W UPS uninterruptable power supply
OPTIONAL EQUIPMENT
Dew-point analyzer Oxygen analyzer Electronic flow meter Output sterile bacterium filter
Pressure and temperature transmitter for
air feed
72 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
LCD TOUCH DISPLAY CONTROL PANEL PROPERTIES
Total work time display
Automatic or manual operation
Measurement of gas purity constantly or instantly (Optional 30 days purity memory)
Adjustable time settings
Language (Turkish-English-Spanish)
One touch technical service contact details
Optional alarm with sound or light on demand
Automatic stop control when outlet pressure increases
DRY AIR COMPOSITION
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
73
MODULAR OXYGEN GENERATORS TECHNICAL DATA
MINIMUM OXYGEN OUTPUT FLOW WITH COMPRESSED AIR INLET
PRESSURE OF 7,5 BAR (g)
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
FOR BIGGER CAPACITIES AND MODELS, PLEASE CONTACT WITH OUR TEAM
74 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
REFERENCE CONDITIONS 2
Oxygen Output Pressure : 5 bar (g) / 87 psi (g)
Oxygen Dewpoint : -60°C
Oxygen Purity 93±3% With Change In Operating.
(All Generators)
Unit Inlet Air Quality : ISO 8573-1 : 2010
Oxygen Quality : ISO 8573-1 : 2010
1 WITH A TOLARANCE OF ±5% 2 CHECK REFERENCE CONDITIONS 3 PLEASE CONTACT CUSTOMER SERVICE AND/OR REPRESENTATIVE FOR ADVICE
FOR OTHER REFERENCES PLEASE CONTACT OUR SALES TEAM
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
FOR BIGGER CAPACITIES AND MODELS, PLEASE CONTACT WITH OUR TEAM
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
75
OXYGEN GE
OXYGEN GENERATOR
TWINTOWER MODEL
Advanced System in Gas Separation
Oxygen Production Unit
76 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
ENERATOR ADVANTAGES OF THE OXYGEN GENERATOR
AAG oxygen generators produce high purity air from compressed air. It provides a continuous supply of with
competitive prices compared to alternative sources.
AAG oxygen generators are designed to amortize your investment rapidly by saving on oxygen consumption
in big quantities.
OKSIPAK can also be connected to an external storage unit to store and cease production/consumption when
in need.
STANDARD EQUIPMENT
Food pack filter kit Medical kit Remote GSM control PC Access with ethernet connection
650W UPS uninterruptable power supply
OPTIONAL EQUIPMENT
Dew-point analyzer Oxygen analyzer Electronic flow meter Output sterile bacterium filter
Pressure and temperature transmitter for
air feed
REFERENCE CONDITIONS 2 OPERATING LIMITS
Compr. Air Effective Inlet Pressure : 7,5 bar (g) / 108 psi (g) Min. Ambient Temperature : 5°C / 41°F
Oxygen Outlet Pressure : 5 bar (g) / 72 psi (g) Max.Ambient Temperature : 45°C / 113°F
Ambient Air Temperature : 20°C / 68°F Max. Compressed Inlet Air Pres. : 20°C / 68°F
Pressure Dewpoint Inlet Air : 3°C / 37°F
Pressure Dewpoint Oxygen : -50°C / -58°F
Unit Inlet Air Quality : ISO 8573-1 : 2010
Oxygen Quality : ISO 8573-1 : 2010
1 WITH A TOLARANCE OF ±5% 2 CHECK REFERENCE CONDITIONS 3 PLEASE CONTACT CUSTOMER SERVICE AND/OR REPRESENTATIVE FOR ADVICE
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
77
LCD TOUCH DISPLAY CONTROL PANEL PROPERTIES
Total work time display
Automatic or manual operation
Measurement of gas purity constantly or instantly (Optional 30 days purity memory)
Adjustable time settings
Language (Turkish-English-Spanish)
One touch technical service contact details
Optional alarm with sound or light on demand
Automatic stop control when outlet pressure increases
DRY AIR COMPOSITION
FIELDS OF APPLICATION
Oxygen gas is used in a variety of industrial applications.
HOSPITALS, LABORATORIES, OXYFUEL TECHNOLOGY, WELDING, BRAZING AND STEEL CUTTING, FISH
FARMING, OZONE, WASTE WATER TREATMENT industries are the main sectors.
78 Rev. No: 017 Rev. Date: 20.11.2019 www.aagmakina.com / info@aagmakina.com
TWINTOWER MODEL OXYGEN GENERATORS TECHNICAL DATA
MINIMUM OXYGEN OUTPUT FLOW WITH COMPRESSED AIR INLET
PRESSURE OF 7,5 BAR (g)
OUR COMPANY MAY CHANGE THE VALUES IN THE CATALOGUE ACCORDING TO THE RESEARCH AND DEVELOPMENT STUDIES.
www.aagmakina.com / info@aagmakina.com Rev. No: 017 Rev. Date: 20.11.2019
79
NOTES
Rev. No: 017 Rev. Date: 20.11.2019
Merkez Mah.İdris Köşkü Cad. Kutucu Sok.
No: 3 Pierre
Pieere Loti
Loti EYÜP
EYÜP -- İSTANBUL
İSTANBUL // TURKEY
TURKEY
444 73 85 +90 (212) 563 83 55
BASINÇLI HAVA SİSTEMLERİ SAN.ve TİC.LTD.ŞTİ
www.aagmakina.com info@aagmakina.com