0% found this document useful (0 votes)
471 views26 pages

O-18 Cold Water Fountain

about drinking water

Uploaded by

Dmitry Ivanenko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
471 views26 pages

O-18 Cold Water Fountain

about drinking water

Uploaded by

Dmitry Ivanenko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 26
PLANRECORD 1. Apr 08,2018 DRAWN FOF 2. hr. o7, 2015, DRAWINGS FOR 15 WORKNGPLAN LAN oF 10808 H.No. 10868/809/810/811 Cold Water Fountain MODEL UWF-52 FINAL PLAN FINISHED PLAN FILING No. | _O-18 STW SETTLING Co, Le No, 10808: 440263 CLASS: NK-MO_ HiNo. 10800: aaaasd owes avaurenn Hino, 108%0.qa0255 cuss ay auroucaee Hino. 10691: £40266 CASS ASG Acumen ceo 0. Ota “Jour, 0 Kanai er @ Ranek W USHIO HEAD OFFICE TEL: +81-896-94-12: FAX +81-808.34-196 a DesioNGow, TEL *84-808-96-1407 JW - 2206, FAX 481-6066 5: ORATVEMILS MABARLCTY EME Ree WORE Tee USHIO REINETSU CO., LTD. © poe woot ars J ww =595, Dimeraie Fath 35 nm Heat S47 nm aaa Front panel 305504 (Ha ine Tai) ee Cobia 'SUSI06 (Haine fish) Drsinage oe usa06 weigh 2g Goong tok copciy 3 iter Copal fr col olor spb 13 tes roar Retigeront | Comgretsor Hermetic ype Recbrocaing compressor (130W) One Condenser ‘urinated tube / ir coled pe Cooler Stainless cooing tk wh coalng coll ending Condenser on ‘Shge-hese mar (1.4), Fon 6110 Refignont CIS (Charged regent: 1055) ote emparatuecontaler Thermostt(Fued bps) Mogaet wav wih es anvoier ‘Operon methes Push bation 7 Foot pol method ‘conection — | Suplywaterniet 5-172 (Win bitin sane) Drain eutet or ug for ong Tank 10 wih ean cop Conaiion | Aebiont tmperture os t ‘Supply woter tegersive | 725 Pressure of Spel wor | 0.07~ 0. 6uPe Tete Power surly ‘Sagle-Phose 1107 (100), 6OFe Choractertic Freie eure Sta Poner consunpton 260 Tecesaoy ports over supa card (on), 3 core Touring brocat (wth serena) pla part (Only Tor UAF-525) eter Server (605-8020), 22 = = ry nm_| war conse seccreanons| Pisco A toe. Owe=s2 7 Uw Oe cen [uveteumote| vruiware | al = * 3, er air ma Tio ocd tofio e=s2-01- ee r ee WF=52 / UHF-525 ae « 360mm = 32mm a 367mm “en co susios GFomaNyS =a) Eazrs SUSS0e GruaWN75>t) mae suse wae 2a us 08m SL oo Bae mason | aa ‘2eavssoaan (10H) ee PaRNsVaa-F / wR ue aeulaMRTD2 mao wae=2- (aw) 979 F110 7 CT S40 (otERR: 1055) ane ooen99 + ED RaBKH Oo-OF) 2o=}syha-3- a wi nos [ROH 7 wa P5172" (aNu=9- mB) axa. Po aBSDORIOD iowa TREY oe eae 0-35 wo 735 t AER 0.0) ~ 0.6 ae = ‘we T1O¥ (4 10V), 60H = 4A = 268 W ae ean (nh Se ‘er (ean) ano (UWE BS aa) ‘ena (G05-a0iW), Ww Prine | wan coo sreenearens sina WooeL uw=s2 / UW ses See . A [ARBRE RS PP aa [pro eaT ra . iy — San a eon sna] OUTAGE aod, FPS - snd ‘wossaudhoS ws amas ecteneass : oiniaty meant aa (asa) xe pus {ssn angen pee wossait0o a Siew vaumaraens > wed 0 eH ene (a) awa nies sod ino av + area (hu) o AIG 7 aun. muno wivaa uasnadNoo von acrceey 5 SAWAISNOA Woo ONTIOGO ee (eosee-an) I San aay Tigo (sassy Ava) I ‘auae = 4 ‘wazniRss Wsl¥n Pd enone Dine ONFIOGD inva ONTIOO aw euwarne J WYHOVIO ONiaid BSLvM WYHOVIO ONidid INVESORASE ea Sear y aT mol SE te “£20246 AHBCISZS—MN PER | RE Pau] HP 'SCS—IMN Ut |e] total ay20n0 §) c= ot ewoone 6 AAZTINGLS USLYA “sel al __ POD OA oc Pn i mac Teen = 1eees SIP OTT (GOOud WILVM) TX BE=W2=Id ~ BARI SIP --WATONG ‘omg anes ana ENDW (aces) —pcaun woul Fa) BONES =! t ' i cS elt | i gs) ean : ty Sa ' i ' i ‘ a WRU ovORRAE(PTCAS~9, BRBIL-EBO) © =| [SWtS0) FHOsTeRIL, FMR SE DURE T ESS, (R50) ORBLE (SBN) EATLET. (29ED ° 2946x27) 2| | 1-2 Teol eave, PAAR] eocusmmOsDeRTLT, o [WABI ebCSIOTET UBT, (Syl V294 HKO7) T=3 Pereae Oe) ], [Freak CH) lebetesay o 4 HUFL, EMEA EEUTBLET. 124 (EWaI DS TPTCAs—9). TBRBUL-1envUEF. o 1I5 RHEL RSSERATS. o 3| [ey sp bo-watyF, 97 DE-9, RST TUL ORM oO 2a 1 BRUT ONRRABI— | ~ 1-2etOeMeRTT. o 2-2 KMURBRE RAYS, o | “GE Team ca. Tule >o—] anime AL Cees To, TERE TTN IE GRCRURY, PAR) OMMLIEEE MOET, : Water Wey _of replace UwF-52 T OF vaplacing Fefrigerating evele, (including PTC starter, overlord relay.) 2 TA Tate the serew of “Front Panel” off, Grip the down wide and take the ‘Front Panel” off with pushiag the “Pedal”, ° :| (Screw 4p 2) THE Toke the “Faucet” off, Thon loosen the screws that fT the ‘Drain Panel” and pull the “Drain Panel” out, ° 4 (Screw 4 6) TO Loosen the screws that Fit “Cabinet (leTay” and “Cabinet (eignt)" and take thon off, 7 Td _Ranave “FTC starter" snd “Overload relay* fron compravsar, o 6] [isa ~eepiece the davaned pares, o % ferlace of central svich, Tan gotar, wahlay Viner nt a | [ET Sene way oat order with Ly toy of replacing ratioerat Le 11a 122, 2 2B Raplace the Gaussel parte, o (ete) “Sensor” ie fitted with ‘Drala Panel” thre the TitT ag pose, This sensor ie sasy to he damaged, 0 cure shoulé te taken to deal with Drain Panel, : S| _ Wve owas wea eee a pe Fre Ess a Ee ee E emia A Aiea” vnt-52-01 PLANRECORD 1A. 08,2018. DRAWN FOR OSHIMA SHIPBUILDING CO,LTD. H.NO. 10808/809/810/811 SPECIFICATIONS OF AQUA COOL ‘SPARE PARTS LIST FAX: +81-696-94-1208 53, (REATIVEHILLS, MABARLOITY, EHIVE PREF, JAPAN USHIO REINETSU CO., LTD. ~ verrotney 09 coamay HEAD OFFICE TEL: +81-808.34-1230 FAK: +81-898841231 TEL; +81-998-34-1 DESIGNING DIV. oe ' “SPARE. PARTS LIST ‘SHIP NO. ‘ pa co 2 7 os) cone J a | FILTER ? 1 o 2| ouster Po conser =P, i mes = [ama |, hee at : - Fines ee fal [ARRAS wal USHIO PIP I-IV Wks AQUA COOL INSTRUCTION MANUAL MODEL UWF-52 ecwe Lomencresn, ‘oes rexd ths ration anal cael ORDISRES RML REE ‘e8esure tobe his nstcton man reading BCE Contents BE EDIE Safety Hints IRETSOTAD EL Instructions for the Contractor Specifications SMOBEA Lb fe B Boerne 9 Component Names and Functions RELORASAIEOUT Safety Caution Label Lieu soe STD Proper Handing BEANO 13-14 Customer Care RE IREN BALE er 4 Before Requesting Repair RENTER OO MRIREMI, CO MRRLOOTE EACREO SARL CBIR EED UREN, ACR SAE RL, TOEFOL, BFF ER, ORREMUIEROESICN STURT. UBOETEE, ABE Cerammensaetaae Phameences, Safety Hints (2sefore staring to use the product please read safety ints careful to get the best out of ts perfomance. ‘Safer Hin contalnsprecauvons of ric Importance to ensuring sty and should be served by all means during operation, The flowing markings ar used inthis manual 19 draw attention information of etre imparance incarect handing could tnearinahuman death or ARE & cag | BoERUEOETEE IE ANB | S282). Sannwone Hieehdnaento. URW, RE RB SURE - XY el ‘DSUAMBERLET. Sever ry. Incorrect handling could cause a ZX WARNING Savina erratic Ascuon | S585 “1 The term pyscal damage eersto an extended damage to houses, household properties, vestock or pets BRO) Example of pictorial symbols ® ARDERLABE OOWPIECEREP G ering statement ori pte ata point pmet | emuet.) ‘that the disassembling fs prohibited, orem | ear ty ho Ls ERLEF. ) Dial the power plug out ofthe AC outlet MBIT SBE BSCE moe FA— HLT HLA TARR MAICMRICB ROUSE Ol - BFC RSUBTLOMBL DET, aN WARNING Leave clearances around Leave dearances oft east 10cm Sraund the uni. These dearances ‘help preven faites or fs, e Set up the unitin firm position on a sound, flat floor. vertu or falls could result in injuries. soir foe HANS LE KODD SPRROS URMILA HD Bore BRAY BREAOR ciemves, AE PRE MUEStH DESSRORBICE YES ALBA WABI TCE BAIS 7eMaOWM CALNE C ETS 7EIB UH, AP ROMER ET. EHRLPRMBROTIEICeD RP ASOREIEDIST, BERMICLO TE, BRIL—h-OREDE BRI Loe NTO De, BRORBICRUET. BIO FORAGE Ria ICL cee @ Leo SoA When installing Do not instal the unit in a place that may be exposed to splashes or water or in a damp place. Electric leakage could cause clectial shock hazard or fires, Beet ® aed VY Ground the unit positively. Lack of grounding could cause lec shock hazards in times offalures leakage’ ecg Do not press the back of the product against the power plug. ‘The power plug could be damages, resting into electrical shock hazards ortees. 8 Do not install the unita place exposed to direct sunlight or neara heater. Such locaton cn bea couse of faautes or res. 8 Install a circuit breaker depending on the lacation of the unit, The absence of» circuit bresker could cause ‘lec shock haze Have your dalerinsallon, Ne SBUITESLE RRISALLOAY Cy eR CES TE OMRLONNT Best PHBE RRL TRATET, eaUET ye ® 5 wares BRI PRRIS TOMA CORY, ty PORLAAAOSE HAEBLEOTE BR ah RAORBICR ver ERED CECE RWIORETRAT ELA RPARORBICEIET, RNKECRET II ESRBUTE BRROMEICRET, me BRST ey cmos CHER BUA ECU MEME SICERIDIE marace ASRMPALOMELGS ceneuey A WARNING when Using ower the unit froma AC outlet rated at 15A or higher, without sharing it with other appliances. When the AC outlet shared wth ether appliances, the branch attachment could be ‘overheated and fre ® Do not use the power card or power plug when they are damaged or the power plug loosely is into the AC outlet. Becta shock hazard, shorts and res cule accu fun the unit only atts rated voltage. Running the unitatavotage ther then ting could ied elec sace haar res Do not hold the power plug with wet hands. eat shock hazards cou ® Insert the power plug into the AC outlet to the base of the blades. Clean the power plug pertodically to avotd dust. couldoccut ® enor ZX WARNING when Using ANS ABs BRUUCESLE wHIAGeOHAwA BORE Ts a BPI 27 MA FEANT RE MTIAR SSE SudBRL Jeet BUR. ears Inthe event ofa gas leakage, ventilate the raom ‘without touching the product or AC outlet. The product could explode by catching fre, leading to fires orbus. MED HICROTY, WERE TV BOTE ROERIC RU PRRROR BRET, 8 ae SEAT Lak eT RRBADA—7THAT ER neve, BUTE aR DSP ASORGICRIET, 2 BRISI ERS BRI-KeRRS [DPR RSI aCe SRP RN RLORD emuE, (ae) £ eee Do not climb up on the product or place objects on top it. Overturns or falls couldesutt ininjuries. 8 Do not use an inflammable spray nearby. ‘The spray could catch fre as aresultofasparking tlectical contact. Do not splash water on the unit. Water splashedion electrical pars could ead to eles! Shock hazards or fies @ x] When unplugging the unit from the AC ‘outlet, do not hold by the power cord, but by the power plug. Hoiaing bythe power cord could cause electrics shockhazards, verheatng, cfg, sea = Ags BEIESLE BEI em, WRLEY. MIL FY, BMIERIFEY, 31K, AUD TeU. Tebdtate). FAMOUS BAMA. MALIEY List & as — Posi RP omic eT. ae ERRHALADAGONICARLT JL oct BALE RMT Facenoues. apa Cia EORED ESBS, RABEL TRRI 9 FERS CE RnokemReiTSCEREX RORBICBIET. BOBO SeREASMNCIEEU. 5 ClCH L ZX WARNING when Using Do not scratch, break, modify, bend or pull with undue force, twist, bundle, place heavy abjects on, pinch, or heat the power cord. The power plugcouldbe damaged resulting into electri shochazards or free, [be HER, ate ance an aad secant archalarepatie ane ‘The nit could fre oF rmafunction, causing human 8 Whenever faults, such as a burning smell, are noticed, shut down the unit, pull out the power plug, and call your dealer immediately. The units table to elec shackhazacor fires. nt SRMCRACESGUES OTHALS BOSD ey ASIC RR OMMPOR IC LSEM PRR AD RECBUET, Before leaving the unit out af service for an extended period of time, discharge water from it and pull the power plug out ofthe AC outlet When the rinkis decomposed rte insulation s graded lactic shockhazads shortages, and fre could ocr Secenerae BY TROBILDTBAANBASE PH ERL MEETS (waxes mat p ® a) et Sono emacs oe NBOTE peezvomameLc « Frocwnonmess 9p 2 GL in BAD, BESARBOKLT C Eh, EMI REED) 277ERM BEE AIRC SMBICR CEES uET. ms) MICK, eemeNT SRN ave, 87K FE0.07~0.6M Patt ce AMNORDER IEE, 7X CAUTION’ when Using Refresh the drink in the tank dally. \When the erinkis decomposed t could do harm a yourheath oo Do not get fingers or sticks into the ait Inlet or outlet. Thesecbjeascadinetee gg esisecmnghaie SG] 8 ass water for 5 minutes once each day. Remember also to clean the inside of the tank periodically (about once each month), “These precautions ae necessary to prevent the decompastion of ‘Observe the source water quality. The presence ofbacteia ould do harm to yourheath, e unit ina feed water pressure range of 0.07 to 0.6 Mpa. Use of fed water out of thisrange could cause a water lenge, SS & LHEFSDEADEEY CREO RESET » ed ABS MOWACICAMPSI TRE TCE smear ‘eEEEBIORADICADKRPTIRRE RRL THER. exci sexcsi2 SPALL RARE L COIR T FEU, SAEOR WOE CRBL ETL ADM POR, AEMILREDTACEIEUES, CDESC ERSDE RUE BEOREM BUH THRO, ORL W ERR LIMA ema aeRL cb ok FALTCEEO IC BUSKIBUER, REREBETSES CRAMLOROTMOReREMET st, mE EEPROM? YAR ECEMELT CERT, RRM ERMICRUI TZ A— MOREL TCE ware i, paca Bp wow EGE scorn Hm CREST LRM RILEY Instruction for the Contractor ‘Conecing the water supe pipe ‘Connects water suppy?51/2 pipet the water spy poet ‘onthe vghtside ofthevearpanel ‘Connecting he dsinage pipe ‘Connects danage Pi pipe athe aainage orton he et feof the earpanel, otetport 1 f Inetpor 512 ‘be surat stich aunonandcheckeap atthe fos The nitaule ou water or scund rus ese ding Sertion when ieusdin ozone where Mah presi ‘in watelesalable vest ghen the mn taporatch cammeraly ass presse eucerto Ifa P¥¢ poets sed allow theadhesves ty ty fore leaing wate hough the PC eto preven ther alerting inated othe inking ater, ~Séeuiting the unit of the Noor ‘*Toprevent the unit tom overuting, ether use the accessory backets or secure teu directo the foor by using cornmercaly avaiable anchor bok, < ‘Asta brackets on both ides ant secur ther ith ‘anchor bas, Meccewpate ‘ewompsieat ona - ‘remove the font panel and damp the unit rectly tothe or wth anchor bots, Foot Ein. tk te Specifications Rated voltagetfrequency) © Width un ete a oF p Exeemal dimensions Depth ein a = Height 947mm = # & & (a # BR) FET 10V (60H) TOV, single phase (6042) x= & 8 8 R A Rated power consumption 268W u & ry a Weight 22kg ONRGAME LURE COLE TT 777 RARER IY CHL EOMMEITT. ‘The rated power ensumprion's power corsumpton ofthe AQUA COOL when srun under ated voage at an amblnt temperature of 30° cUBEROBHMO—MURDACE EVES, ‘eSpectcaons ae subject to change without ree for product improvement purposes SROGEALIESE Component Names and Functions EKER Drainage water. exes. Cole ainage wate, 4201 Faucet mrKOUTCECATH, Deking wate comes out athe faucet BID/LAIL Front panel 38827 Push button Freeonsmiexssies, Prestolet enn wate out ofthe face, Seek ge (SBRESA) Water Valve ACEBOACRETREATS. Regulates the wate ses utomancay tke _Drain cap PIROKGELATH, Dente tence te water Hib Pedal ROSeINSmAKELES, “Tread et ikrg water ou of hetaucet. 48($@51_Mounting camps SRLREMETSEAERLET. Ureta camp the unit tothe ce KO Outlet BAREMELTAALET. CGonneetadain pipe to he ai porto discharge dain water A@KOAKL—F—PHD) Inlet(with built-in strainer) SOKWEWRLTIEALET, Connect feeds pipe tothe feed water porto feed water 7—Atals Grounding screw Bry aRERUNTCEEY, esuretogrounatheunt tha rounding cable, p— eo— ‘RUBTON coke OV, single past Power cable P-AKK Grounding clmpstwth screws) REEOEBINMCOWT Safety Caution Label HSICMBLSASNDRRICOUT, BRSAULERUAH TOT, RAASTMELBSICOACEEY, ‘caution labelis attached to draw attention to matter that seems to requle special notice. Check caution label to ensure safety A 2B Z\ CAUTION BROBND May be decomposed SRIAWT SNE Pass water for 5 minutes: ALTE. once each day RABI DERI ERNIE, LEBAARLY LEB OMS RAL TRUBAT cree, \When caution label attached to the unit are removed or characters are found blurred, purchase new labels from your dealer and replace the existing labels. NTE TELUMEW O° Fe cara i | SREOLOE fncR 7S Fear ED HRLBAT TOU. AUDRRENE, REVERIE, BUTI PEAHMSSSC, KEKE LAUT, ‘KISH HOET. NEVER TCTEED, OMAR OREM IEFOT. 39 7E BEBARDARED SUT CIEL, BRSIE~ Someever, | MRERLOSEE-LHZLE ony 57837 eee LMOLONNMRE NE Fonte SERA KORDSESICRUET, omEEMBSE SH RETI TENE TSRD caret RU onLla7o7eRemeemul, BUMRTSE 48, Br MLEMeRO TCE, 2 wkBeome ARS PEL OKRICBOI IRC, BU CCrEED. Spkais5~ toma wae a Orkaler'G~skgien’ ses. BRU Ae MRemERMAAT ORS NRE LAY a u Proper Handing 1 Venting the tank Fis ofall please confirm pug into the AC outlet. With the main water tap open, ead the peal Wate wil rst come out of ark together with ai unt waters accumulated the tank Continue vending the pedal until oni water comes out Since the fountain ‘becomes regular height during this Incenalcove it wath a cup or gas. Alrverting ‘wil tae four to five minutes to complete, Teeienennes Starting or Stopping the AQUA COOL ‘enserthe attachment plug ino an AC outlet start cooling Ciled water ul be ready in about sD minutes. {To stop the AQUA COOL, sconnect the tachment plug rom the AC ote. “NOTE! ‘low for atleast 3 minutes before running the ‘AQUA COOL after hasbeen stopped by ‘Feconnectng the attachment plug into.an AC ‘ute 2 Adjusting the fountain height tthe fountain sco heght ads the hel wth ‘hemi tapon the feed waterside ‘fountain eight of 1020 em recommended toe) ‘The water pressure isadustable between 007 and 06 Mpatbetween about 07 and 6 kgfen6 «NOTE -Anappioptate fountain height may not be _tanabl fhe water pressure sow. 3 RKOLON ANGE RMAAHME RITE E Lic kU saben CeKCRET, A BRAC BRED aSRLLNTE IE < Feable esaimmxec ccna, Hieiaxe AOU RE Cae, SACERICRS DaMesAMC SURED SHEL TORE kev Us) otc RUMCERARESICLTREETE. Diese). MALETCBUET. eAimansyonomBe Lees CLC BEAMOLINRED SACKED: | ET APMRCLERE ACSC eKEYET, cre ARS, $2 7PICKORET SC LICR SARTHY, waren) gen. Sc unuREite LLuPAreREaBMRE DiCBUBRILIBSEERBIES. COBINE @mLCossReck RIFE, RcnomaE SEGURA ERARUCT SRL AERERLTS Fev. Dy Drinking water Press the push buton or ead the pedal drink eae 4 Keeping drinking water clean ‘ePass water atleast once each day Letwatercome out of the faucet for about S minutes about 30 minutes before using the ‘AQUA COOL each day to ensure that the water Isalvays lean. Leaving water accumulated in the cooling tae foran extended period of ime would remove chlorine rom the water, making more susceptible to decompostion ‘Clean the inside ofthe cooling tank once each ‘mont, (For detailed instructions, see Customer Core Tips) Ko —_——— Water may come aut ofthe faucet during ‘cooling operation, but this the reso ce being formed inthe tank uring cooing ais ot alu For the intl period of instalation, the smels of the oll adhering tothe pipe oof the PYC pipe ‘oul be imparted tothe crinking water. These smells would be evaporated gradually with te. Butifthey ae of concern et outa suicient quantity af water fom the unt by leaving ‘Wate charged fam ea whole day and nigh BFANOLA TE POT IH Wie iE BE EEUCAS IRIE WEBEL TER, —— seo MIRUTE MRICS EEO ROREKDIEF. BETS 7eRC LEB Ba Feye reas hie DaErs FER. CHER a oF BL TAORIENL WAIT HRNT IED. O=BH,_ EDL, ADI, YIF—, Pa WRERBDRUTCEA. UNEP TI AFY PmRLIOET. ) ORMRPIRR ER RSL URANATES SUE | SieaccaceALT (RES Fea ey SKEET, OMIT ROA ETL. MEU RL RU FICS! WTRF LT CHa (ABE FRET LTR HAE TCE Uy Actin semiby ee ening he MUA COL Ou Seer Eieded Pea Tie) Dain the tank of water nthe winter petod or ‘when the air temperature iil to drop tothe degre of freezing watrin the nightie Be sure o drain the tank as well befae leaving the Unit out of ence fran extended period of time. Leaving the uit vith water inside fran extended period of ine could cause the water tobe decompose, thereby making the tank and faucet moe lable to damage. Drain the Tank of Water ) (1) Disconnect the attachment pg from the AC oute. (2) Close the main tap. {3} Remove the scew unde the font panel and pull fut the front pane! ealquely downward (4) Open the water ran port cap to receiver water inacontainer asit comes out Drainage wil ake four to fve mines to complete Water dain port Bucket ir (EBS NSpTIZ Before Requesting Repair WALCLEMELR ES, ROREBWNIE > TH SEAL LVOREBICCIINCTEEL, ‘When the unit malfunctions, check he flowing pants fst before cling your dealer HELBUES Theunit won ran Si pone eaabie, RTEBIETROT A POTNGP COREL, PREOILM DSS ABORTED, Sis et ben Sn ofthe se nat own? kORARLES Water doesnot chil well CRRBARL OTIC REEK SBRoskecomLRocasvkenn, ge there beating cei eae Hosa urge vue hed water been oneuned? sere Water wont come out EAU CUETS. irecnaea. svat soppy vale BeSseues ‘Theunitisnlsy eBuLRILCUET a. RPE BAN TENE SD. Diep eaesbloeBin Tomek. le the ania? Ig the ut tah thay suounding object Y USHIO USHIO REINETSU CO.,LTD. '53, Coaive ts, mabe Gy, Eni Pre, 7940059, Joan © Head Off emal_umogubirenee 0885, We, Ono, mabe Cy, Ehime Pret, 758220, Japan 1D Tokyo rach phone sateeasoart tax sereneszanes mat _usho-suppont @ushirinesco ip Ko 854, We, Onno, aba Ci, hina Pre, 7582206, Japan shone: 1-000-59-2400 fox #0-000626069 ‘ngeboblig SF 297, ga Sinan, mnt Tobe, 105-021, pen prone #8195725-700 fax ¥01-36755-700 “The apecticalons, designs, and Information in this manual are | zoj4 mes a 27 Rave subject to change witout notice PaIa2408-x001-00 Savona 15 ia3280201-

You might also like