100% found this document useful (1 vote)
2K views56 pages

Gem General Cat

This document provides a product catalog for GEM Sprinkler Company. It includes: - An overview of GEM Sprinkler's breadth of product offerings, which includes over 250 fire protection products and 1,200 related items. - Information on GEM Sprinkler's listings and approvals from various fire protection certification organizations. - Details on GEM Sprinkler's services including customer service, research and development, and leadership in the fire protection industry. - A table of contents that outlines GEM Sprinkler's product lines which include standard response, quick response, special purpose, intermediate level, conventional, residential, and extended coverage sprinklers.

Uploaded by

valerio.garibay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views56 pages

Gem General Cat

This document provides a product catalog for GEM Sprinkler Company. It includes: - An overview of GEM Sprinkler's breadth of product offerings, which includes over 250 fire protection products and 1,200 related items. - Information on GEM Sprinkler's listings and approvals from various fire protection certification organizations. - Details on GEM Sprinkler's services including customer service, research and development, and leadership in the fire protection industry. - A table of contents that outlines GEM Sprinkler's product lines which include standard response, quick response, special purpose, intermediate level, conventional, residential, and extended coverage sprinklers.

Uploaded by

valerio.garibay
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 56

Back

G E N E R A L P R O D U C T S C ATA L O G
Back

Company Identification Listings and Approvals


GEM Sprinkler Company offers the broadest line of GEM Sprinkler products are listed and approved by
fire protection system equipment with worldwide various fire protection product approval laboratories
availability. and organizations. General listing and approval
information for the following organizations is
provided with each of the product descriptions given
Breadth of Line herein. Refer to the applicable Technical Data Sheet
GEM Sprinkler offers more than 250 fire protection for specific listing and approval information.
products and over 1,200 items used in the fabrication
of fire protection systems, including sprinklers,
nozzles, valves, devices, pipe, fittings, hangers and FM
accessories.
Factory Mutual
Scientific Services Laboratory Research
Corporation
Verband der
Underwriters Schadenversicherer
Underwriters Laboratories’
Laboratories Inc. of Canada
Underwriters
Laboratories Inc.
for use in Canada

Loss Prevention
Council

2
Back

Customer Service Leadership


GEM Sprinkler serves a diverse group of specifiers, By paying close attention to the needs of the fire
including architects, engineers, contractors, and protection industry, GEM Sprinkler introduced the
associated industries, with a nationwide network of first early suppression fast response (ESFR),
distribution and manufacturing facilities. residential, and quick response sprinklers, as well as
the first water mist nozzles listed for installation per
NFPA 750. GEM is committed to continuing our role
Research and Development as a leader in the development, manufacture, and
GEM Sprinkler products are backed by the largest marketing of quality fire protection products.
research, design, and development staff and facilities
in the industry. Our experienced staff of engineers is
continually working to develop new types of
sprinklers and valves, as well as special hazard fire
protection devices to fill present and meet future
market needs.

3
Back

GEM TABLE O F CONTENTS


Standard Response Sprinklers Special Purpose Sprinklers
Model A, 5 mm, K=2.8, Pendent and Upright ............................ 10 ESFR-1 and ESFR-25, K=14.3 and 25.2,
Model A, 5 mm, K=5.6 Early Suppression Fast Response, Pendent ....................... 22
Pendent and Upright .......................................................... 10 F927, K=5.6, On-Off, Pendent .................................................... 22
Q-71 Horizontal Sidewall ................................................... 11 F892 and F892QR, K=11.2,
Vertical Sidewall ................................................................ 11 Extra Large Orifice, Upright ............................................... 22
Model A, 5 mm, K=8.0, Pendent and Upright ............................ 10 F960, K=5.6, Dry Pendent,
Model A, 5 mm, K=5.6 and 8.0, Recessed Pendent ................... 11 Recessed and Upright Sprinkler ........................................ 23
F692, 4 mm, K=5.6, Concealed Pendent .................................... 12 F960/Q-46, K=5.6, Dry Horizontal Sidewall ............................... 23
Issue D, K=5.6, Pendent and Upright ......................................... 12 F960/Q-48, K=5.6, EC, Dry Horizontal Sidewall ......................... 23
F950, K=5.6, Pendent and Upright ............................................. 12 G100, K=5.6, Quick Response, Institutional .............................. 24
F950, K=1.4, 2.8 and 4.2, Pendent and Upright ......................... 13 G102, K=5.6, Quick Response, Institutional Sidewall ................ 24
F950/Q-46, K=5.6, Horizontal Sidewall ...................................... 13 F890, K=8.0 & K=11.2, Light Hazard, Pendent .......................... 25
F898, K=11.2, Large Drop, Upright ............................................ 25
Quick Response Sprinklers
Model A, 3 mm, K=2.8, Pendent and Upright ............................ 14 Intermediate Level Sprinklers
Model A, 3 mm, K=5.6 Model A, 3 mm, K=5.6, and 8.0 ................................................. 26
Pendent and Upright .......................................................... 14 Model A, 5 mm, K=5.6, and 8.0 ................................................. 26
Q-71 Horizontal Sidewall ................................................... 15 FR-1, K=5.6 and 8.0 .................................................................. 26
Vertical Sidewall ................................................................ 15
Type 316, K=5.6, Pendent and Upright ...................................... 26
Model A, 3 mm, K=8.0, Pendent and Upright ............................ 14
Model A, 3 mm, K=5.6 and 8.0, Recessed Pendent ................... 15 Conventional Sprinklers
F690, K=5.6, Concealed Pendent ............................................... 16 Model A, 3 mm, K=5.6 and 8.0 .................................................. 27
F995, K=5.6, Flush Pendent ....................................................... 16 Model A, 5 mm, K=5.6 and 8.0 .................................................. 27
F996, K=5.6, Flush Horizontal Sidewall ...................................... 16 F950, K=1.4, 2.8 and 5.6 ........................................................... 27
FR-1, K=2.8, Pendent and Upright ............................................. 17 Issue D, K=1.4, 2.8, 5.6 and 8.0 ................................................ 27
FR-1, K=8.0, Pendent and Upright ............................................. 17
FR-1, K=5.6, Pendent and Upright ............................................. 17 Residential Sprinklers
FR-1, K=2.8 and 5.6, Recessed Pendent .................................... 17 F680, K= 3.0, Pendent ............................................................... 28
FR-1/Q-46, K=5.6, Horizontal Sidewall ...................................... 17 F685, K= 3.5, Horizontal Sidewall .............................................. 28
F687, K= 5.8, Horizontal Sidewall .............................................. 28
Extended Coverage Sprinklers F983, K= 4.4, Pendent ............................................................... 29
Model A, 3 and 5 mm, K=5.6 and 8.0, F984, K= 4.4, Horizontal Sidewall .............................................. 29
EC and QR-EC, Horizontal Sidewall .................................... 18 F978, K= 4.2, Concealed Pendent .............................................. 29
EC and QR-EC, Recessed Horizontal Sidewall ................... 18
F990, K= 4.2, Flush Pendent ...................................................... 30
F992, K=5.6, EC and QR-EC
F992, K= 5.6, Flush Pendent ...................................................... 30
Flush Pendent .................................................................... 18
F993, K= 5.6, Flush Horizontal Sidewall ..................................... 30
F993, K=5.6, EC and QR-EC
Flush Horizontal Sidewall ................................................... 19 Residential Sprinkler Head Performance Chart .......................... 31
FR-1, K=5.6 and 8.0, EC and QR-EC, Horizontal Sidewall .......... 19
High Pressure Sprinklers
F895, K=11.4 and 14.5, ECOH,
Model A300, 5 mm, K=5.6, Pendent .......................................... 32
Upright, Pendent and Recessed Pendent ........................... 19
Model A300/Q-71, 5 mm, K=5.6, Horizontal Sidewall ................ 32
F890, K=8.0 and K=11.2 ECLH,
Pendent and Recessed Pendent ........................................ 19 Model A300 EC, 5 mm, K=5.6, Horizontal Sidewall ................... 32
Model A300, 3 mm, K=5.6, Pendent .......................................... 33
Recessed and Concealed Sprinklers Model A300/Q-71, 3 mm, K=5.6, Horizontal Sidewall ................ 33
Model A, 5 mm, K=5.6 and 8.0, Model A300 QR-EC, 3 mm, K=5.6, Horizontal Sidewall ............. 33
Standard Response, Recessed Pendent ............................ 20
F692, K=5.6, Standard Response, Concealed ............................ 20
FR-1R, K=2.8 and 5.6, Quick Response,
Recessed Pendent ............................................................. 20
F690 K=5.6, Quick Response, Concealed .................................. 21
Model A, 3 mm, K=5.6 and 8.0,
Quick Response, Recessed Pendent .................................. 21
Model A, 3 and 5 mm, K=5.6 and 8.0, EC and QR-EC
Recessed Horizontal Sidewall ............................................ 21

4
Back

GEM TABLE O F C ONTENTS


AquaMist ® Systems Deluge and Preaction Systems
OH-2 System, AM24 Automatic Nozzles .................................... 34 Schematics .......................................................................... 44, 45
Total Compartment Deluge System, Deluge ....................................................................................... 44
AM4 Open Nozzles ............................................................ 34 Preaction ................................................................................... 45
AM10 Open Nozzles .......................................................... 34 Double Interlock ........................................................................ 45
F517 Ready-Riser® ....................................................................................................................... 35 F470 External Resetting Deluge Valve ....................................... 46
VSG Waterflow Detector ............................................................ 35 F445 and F446 Automatic Resetting Deluge Valve ..................... 46
F446 Deluge Valve ..................................................................... 35 B Flooding Valve ........................................................................ 46
Spray Nozzles F430 Thermal Control Valve ...................................................... 47
EA-1 Protectospray® ................................................................................................................... 36 Valve Trim .................................................................................. 47
D3 Protectospray® ........................................................................................................................ 36 Red-E Cabinet® .......................................................................... 47
D3 Large Capacity Protectospray® .............................................................................. 36 Alarm and Supervisory Devices
HV (High Velocity) ..................................................................... 37 PS10-1A and PS10-2A Pressure Alarm Switches ...................... 48
F822 through F834 Mulsifyre® ......................................................................................... 37 PFC Series 100RC, 2000RC and 4410 Fire Control Panel .......... 48
Ti-Max® ..................................................................................................................................................... 37 VSR-F Waterflow Detector ......................................................... 48
Cooling Tower ............................................................................ 37 F630 Water Motor Alarm ........................................................... 48
Accessories for Sprinklers and Nozzles G16AC812 Automatic Supervisory Air Supply ........................... 49
F937 Sprinkler Guard ................................................................. 38 J33AX-5835 Pressure Alarm Switch .......................................... 49
F938 Sprinkler Guard ................................................................. 38 F114 Supervisory Air Maintenance Device ................................ 49
F700 Recessed Escutcheons ..................................................... 38 F116 Supervisory Nitrogen Maintenance Device ....................... 49
F705 Recessed Escutcheons ..................................................... 38 1.5 psi Low Pressure Alarm Switch ........................................... 49
F740 Sprinkler Cabinet .............................................................. 39 General Purpose Valves
Sprinkler Wrenches ................................................................... 39 F512 Wafer Check Valve ............................................................ 50
Escutcheons, Pendent and Sidewall .......................................... 39 F514 Swing Check Valve ............................................................ 50
F819 Rupture Disc Assemblies .................................................. 39 F52/F520/F5201 Check Valves ................................................... 50
Wet Pipe Sprinkler Systems 7800FP Grooved End Check Valves ........................................... 51
Resi-Riser® ........................................................................................................................................... 40 EDC IV Detector Check Valves ................................................... 51
F517 Ready-Riser® ....................................................................................................................... 40 F570/F571 Sectional Control Pressure Control Valves ............... 51
F20, F200, and F2001 Alarm Valves .......................................... 40 F575/F576 Hose Station Type Pressure Reducing Valves .......... 52
Alarm Valve Trim ....................................................................... 41 7700 FP Grooved End Butterfly Valves ...................................... 52
F540 Residential Domestic Shut-off Valve 1" and 2" .................. 41 7700 HFP Grooved End Butterfly Valves .................................... 52
Schematic .................................................................................. 41 BB-SC501 and BB-SC100 Butterfly Valves ................................ 52

Dry Pipe Sprinkler Systems Specialty Items


F3061 Dry Pipe Valve ................................................................ 42 Model A & Model B Strainers ................................................... 52
Schematic .................................................................................. 42 Model C Strainer ........................................................................ 52
F302/F3021 Dry Pipe Valves ...................................................... 43 Model B-1 Pipe Line Strainer ..................................................... 53
F311 Dry Pipe Valve Accelerator ................................................ 43 F713 Fire Department Connection ............................................. 53
F324 Air Maintenance Devices ................................................... 43 F715, F716, and F717 Fire Department Connections ................. 53
Dry Pipe Valve Trim ................................................................... 43 F789 Automatic Drain Valve ...................................................... 53
F326 Air Maintenance Devices .................................................. 43 F350 Sectional Test and Drain ................................................... 53
F328 Nitrogen Maintenance Devices .......................................... 43 Tuff-Loc® Pipe Thread Sealant ................................................... 53

Sprinkler Pipe ........................................................ 54

5
Back
Sprinkler Head
Max. PSI
TYPE Response(6) Hazard(1,7) K Orifice, Inch Pressure Model(1) TD(1) Approvals(1)
3
Upright QR LH 2.8 ⁄8 175 A 513M UL, ULC, FM, NYC
3
QR LH 2.8 ⁄8 175 FR-1 514 UL, ULC, NYC
QR LH 3.9 — 175 A 513Q LPC, SSL, VdS
1
QR All 5.6 ⁄2 175 A 515M UL, ULC, FM, NYC, LPC, SSL, VdS
1
QR All 5.6 ⁄2 175 FR-1 516 UL, ULC, FM, NYC, LPC, SSL, VdS
17
QR All 8.0 ⁄32 175 A 525Q UL, ULC, FM, NYC, LPC, SSL, VdS
17
QR All 8.0 ⁄32 175 FR-1 526 UL, ULC, FM, NYC, SSL
5
QR All 11.2 ⁄8 175 F892QR 595A UL, C-UL, FM
1
SR LH 1.4 ⁄4 175 F950 515 UL, ULC, NYC
3
SR LH 2.8 ⁄8 175 F950 515 UL, ULC, FM, NYC
3
SR LH 2.8 ⁄8 175 A 514M UL, ULC, FM, NYC
SR LH 3.9 – 175 A 514Q LPC, SSL, VdS
7
SR LH 4.2 ⁄16 175 F950 515 UL, ULC, FM, NYC
1
SR All 5.6 ⁄2 175 A 516M UL, ULC, FM, NYC, LPC, SSL, VdS
1
SR All 5.6 ⁄2 175 F950 517 UL, ULC, FM, NYC, LPC, SSL, VdS
1
SR All 5.6 ⁄2 175 D 525M UL, ULC, FM, NYC, LPC
1
SR All 5.6 ⁄2 175 S.S. 581M –
17
SR All 8.0 ⁄32 175 A 526Q UL, ULC, FM, NYC, LPC, SSL, VdS
17
SR All 8.0 ⁄32 175 D 527Q UL, ULC, FM, NYC, LPC
17
SR All 8.0 ⁄32 175 A 529 UL, ULC, FM, NYC
17
SR All 8.0 ⁄32 175 D 529Q UL, ULC, FM, NYC
5
SR All 11.2 ⁄8 175 F892 595 UL, C-UL, FM, NYC, SSL
3
Pendent QR LH 2.8 ⁄8 175 A 513M UL, ULC, FM, NYC
3
QR LH 2.8 ⁄8 175 FR-1 514 UL, ULC, NYC
QR LH 3.9 – 175 A 513Q LPC, SSL, VdS
1
QR All 5.6 ⁄2 175 A 515M UL, ULC, FM, NYC, LPC, SSL, VdS
1
QR All 5.6 ⁄2 175 FR-1 516 UL, ULC, FM, NYC, LPC, SSL, VdS
17
QR All 8.0 ⁄32 175 A 525Q UL, ULC, FM, NYC, LPC, SSL, VdS
17
QR All 8.0 ⁄32 175 FR-1 526 UL, ULC, FM, NYC, SSL
1
SR LH 1.4 ⁄4 175 F950 515 UL, ULC, NYC
STANDARD
COVERAGE

3
SR LH 2.8 ⁄8 175 F950 515 UL, ULC, FM, NYC
3
SR LH 2.8 ⁄8 175 A 514M UL, ULC, FM, NYC
SR LH 3.9 – 175 A 514Q LPC, SSL, VdS
7
SR LH 4.2 ⁄16 175 F950 515 UL, ULC, FM, NYC
1
SR All 5.6 ⁄2 175 A 516M UL, ULC, FM, NYC, LPC, SSL, VdS
1
SR All 5.6 ⁄2 175 F950 517 UL, ULC, FM, NYC, LPC, SSL, VdS
1
SR All 5.6 ⁄2 175 D 525M UL, ULC, FM, NYC, LPC
1
SR All 5.6 ⁄2 175 S.S. 581M –
17
SR All 8.0 ⁄32 175 A 526Q UL, ULC, FM, NYC, LPC, SSL, VdS
17
SR All 8.0 ⁄32 175 D 527Q UL, ULC, FM, NYC, LPC
17
SR All 8.0 ⁄32 175 A 529 UL, ULC, FM, NYC
17
SR All 8.0 ⁄32 175 D 529Q UL, ULC, FM, NYC
3
Recessed Pendent QR LH 2.8 ⁄8 175 FR-1 514 UL, ULC, NYC
1
QR All 5.6 ⁄2 175 A 515M UL, ULC, FM, NYC, LPC, SSL
1
QR All 5.6 ⁄2 175 FR-1 516 UL, ULC, NYC
17
QR All 8.0 ⁄32 175 A 525Q UL, ULC, FM, NYC, LPC, SSL
1
SR All 5.6 ⁄2 175 A 516M UL, ULC, FM, NYC, LPC, SSL
17
SR All 8.0 ⁄32 175 A 526Q UL, ULC, FM, NYC, LPC, SSL
1
Concealed Pendent QR All 5.6 ⁄2 175 F690 578Q UL, ULC, NYC, LPC
1
SR All 5.6 ⁄2 175 F692 579Q UL, ULC, FM, NYC, LPC
1
Flush Pendent QR All 5.6 ⁄2 175 F995 520 UL, ULC, NYC, LPC, SSL
1
On-Off Pendent SR All 5.6 ⁄2 175 F927 560 FM, NYC, SSL
1
Vertical Sidewall QR LH/OH 5.6 ⁄2 175 A 532 UL, ULC, FM, NYC, LPC, SSL
1
SR LH/OH 5.6 ⁄2 175 A 533 UL, ULC, FM, NYC, LPC, SSL
1
Horizontal Sidewall QR LH/OH 5.6 ⁄2 175 A/Q-71 534 UL, ULC, FM, NYC, LPC, SSL
1
QR LH/OH 5.6 ⁄2 175 FR-1/Q-46 535 UL, ULC, FM, NYC, SSL
1
SR LH/OH 5.6 ⁄2 175 A/Q-71 535M UL, ULC, FM, NYC, LPC, SSL
1
SR LH/OH 5.6 ⁄2 175 F950/Q-46 536 UL, ULC, FM, NYC, SSL
1
Rec. Hor. Sidewall QR LH/OH 5.6 ⁄2 175 A/Q-71 534 UL, ULC, FM, NYC, LPC, SSL
1
SR LH/OH 5.6 ⁄2 175 A/Q-71 535M UL, ULC, FM, NYC, LPC, SSL
Flush Sidewall QR LH/OH 5.6 1⁄2 175 F996 538 UL, ULC, NYC, LPC, SSL
5
Upright SR OH 11.2 ⁄8 175 F895 596A UL, C-UL, FM, SSL, NYC
3
SR OH 14.0 ⁄4 175 F895 596A UL, C-UL, FM, SSL, NYC
17
Pendent QR LH 8.0 ⁄32 175 F890 594 UL, C-UL, FM, NYC
5
QR LH 11.2 ⁄8 175 F890 594M UL, C-UL, FM, NYC
COVERAGE
EXTENDED

17
SR LH 8.0 ⁄32 175 F890 594 UL, C-UL, NYC
5
SR LH 11.2 ⁄8 175 F890 594M FM , NYC
5
SR OH 11.2 ⁄8 175 F895 596A UL, C-UL, FM, SSL, NYC
3
SR OH 14.0 ⁄4 175 F895 596A UL, C-UL, FM, SSL, NYC
17
Recessed Pendent QR LH 8.0 ⁄32 175 F890 594 UL, C-UL, FM, NYC
5
QR LH 11.2 ⁄8 175 F890 594M UL, C-UL, FM, NYC
17
SR LH 8.0 ⁄32 175 F890 594 UL, C-UL, FM, NYC
5
SR LH 11.2 ⁄8 175 F890 594M UL, C-UL, FM, NYC
5
SR OH 11.2 ⁄8 175 F895 596A UL, C-UL, SSL, NYC
3
SR OH 14.0 ⁄4 175 F895 596A UL, C-UL, SSL, NYC

6
Back
Selection Chart Section 1 of 2
Sprinkler
Temperature, °F(1) Element NPT, Inch Finish(1,2) Wrench Escutcheon(3) Notes TYPE
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
140, 165, 212 Solder ⁄2 B, C F799
135, 155, 175, 200, 286 3 mm Bulb ISO 3⁄8 B, C, P (4)
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
140, 165, 212 Solder ⁄2 B, C F799
3
135, 155, 175, 200, 286 3 mm Bulb ⁄4 B, C, P (4)
3
140, 165, 212 Solder ⁄4 B, C F799
3
135, 155, 175, 200, 286 3 mm Bulb ⁄4 B, C Adj. Wrench
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
135, 155, 175, 200, 286, 360 5 mm Bulb ISO 3⁄8 B, C, P (4)
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799
1
400, 500, 650 11 mm Bulb ⁄2 B, C, L F799
1
135, 175, 250 11 mm Bulb ⁄2 Stainless Steel F799
3
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄4 B, C, P (4)
3
400, 500 11 mm Bulb ⁄4 B, C, L F799
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
400, 500 11 mm Bulb ⁄2 B, C, L F799
3
135, 155, 175, 200, 286 5 mm Bulb ⁄4 B, C Adj. Wrench
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
140, 165, 212 Solder ⁄2 B, C F799
135, 155, 175, 200, 286 3 mm Bulb ISO 3⁄8 B, C, P (4)
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
140, 165, 212 Solder ⁄2 B, C F799
3
135, 155, 175, 200, 286 3 mm Bulb ⁄4 B, C, P (4)
3
140, 165, 212 Solder ⁄4 B, C F799
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799

STANDARD
COVERAGE
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
135, 155, 175, 200, 286, 360 5 mm Bulb ISO 3⁄8 B, C, P (4)
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799
1
400, 500, 650 11 mm Bulb ⁄2 B, C, L F799
1
135, 175, 250 11 mm Bulb ⁄2 Stainless Steel F799
3
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄4 B, C, P (4)
3
400, 500 11 mm Bulb ⁄4 B, C, L F799
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
400, 500 11 mm Bulb ⁄2 B, C, L F799
1
140, 165, 212 Solder ⁄2 B, C F798 C, WH, SP Note: (8)
1
135, 155, 175, 200 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP Notes: (5, 9)
1
140, 165, 212 Solder ⁄2 B, C F798 C, WH, SP Note: (8)
3
135, 155, 175, 200 3 mm Bulb ⁄4 B, C, P F850 C, WH, SP Notes: (5, 9)
1
135, 155, 175, 200 5 mm Bulb ⁄2 B, C, P F850 C, WH, SP Note: (9)
3
135, 155, 175, 200 5 mm Bulb ⁄4 B, C, P F850 C, WH, SP Note: (9)
1 1
135, 155, 175, 200 3 mm Bulb ⁄2 – 2111 C, WH, SP ⁄2" adjustment
1 1
135, 155, 175, 200 4 mm Bulb ⁄2 – 2111 C, WH, SP ⁄2" adjustment
1
160, 212 Solder ⁄2 C, BB, WH F873 C, WH, SP Aquarius Flush Style
1
135, 175 5 mm Bulb ⁄2 B, C F737 C, WH, SP Flush mount escutcheon optional
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
140, 165, 212 Solder ⁄2 B, C F799
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL F799
1
135, 155, 175, 200 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP Notes: (5, 9)
1
135, 155, 175, 200 5 mm Bulb ⁄2 B, C, P F850 C, WH, SP Note: (9)
160, 212 Solder 1⁄2 C, BB, WH F873 C, WH, SP Aquarius Flush Style
3
135, 155, 175, 200, 286 3 mm Bulb ⁄4 B, C, WH, L F875 14' x 14' & 16' x 16'
3
135, 155, 175, 200, 286 3 mm Bulb ⁄4 B, C, WH, L F875 16' x 16' - 20' x 20'
3
135, 155, 175 3 mm Bulb ⁄4 B, C, WH F799 16' x 16' - 20' x 20'
3
135, 155, 175, 200 3 mm Bulb ⁄4 B, C, WH F851 16' x 16' - 20' x 20'
COVERAGE
EXTENDED

3
155, 200 3 mm Bulb ⁄4 B, C, WH F799 / 1948 16' x 16' - 20' x 20'
3
175 3 mm Bulb ⁄4 B, C, WH F851 16' x 16' - 20' x 20'
3
135, 155, 175, 200, 286 3 mm Bulb ⁄4 B, C, WH, L F875 14' x 14' & 16' x 16'
3
135, 155, 175, 200, 286 3 mm Bulb ⁄4 B, C, WH, L F875 16' x 16' - 20' x 20'
3
135, 155, 175 3 mm Bulb ⁄4 B, C, WH 1948 C, WH, SP 16' x 16' - 20' x 20'; Note: (8)
3
135, 155, 175, 200 3 mm Bulb ⁄4 B, C, WH F851 C, WH, SP 16' x 16' - 20' x 20'; Note: (8)
3
155, 175, 200 3 mm Bulb ⁄4 B, C, WH 1948 C, WH, SP 16' x 16' - 20' x 20'; Note: (8)
3
155, 200 3 mm Bulb ⁄4 B, C, WH F851 C, WH, SP 16' x 16' - 20' x 20'; Note: (8)
3
135, 155, 175, 200 3 mm Bulb ⁄4 B, C, WH F875 C, WH, SP 14' x 14' & 16' x 16'; Note: (10)
3
135, 155, 175, 200 3 mm Bulb ⁄4 B, C, WH F875 C, WH, SP 16' x 16' - 20' x 20'; Note: (10)

7
Back
Sprinkler Head
Max. PSI
TYPE Response(6) Hazard(1,7) K Orifice, Inch Pressure Model(1) TD(1) Approvals(1)
1
Flush Pendent QR/SR LH 5.6 ⁄2 175 F992 587 UL, ULC, SSL, NYC
1
Horizontal Sidewall QR/SR LH 5.6 ⁄2 175 A 545 UL, ULC, FM, SSL, NYC
COVERAGE
EXTENDED

17
QR/SR LH 8.0 ⁄32 175 A 547 UL, ULC, FM, SSL, NYC
1
QR/SR LH 5.6 ⁄2 175 FR-1 588 UL, ULC, FM, SSL, VdS, NYC
17
QR/SR LH 8.0 ⁄32 175 FR-1 589 UL, ULC, FM, SSL, NYC
1
Rec. Hor. Sidewall QR/SR LH 5.6 ⁄2 175 A 545 UL, ULC, FM, SSL, NYC
17
QR/SR LH 8.0 ⁄32 175 A 547 UL, ULC, FM, SSL, NYC
Flush Sidewall QR/SR LH 5.6 1⁄2 175 F993 591 UL, ULC, SSL, NYC
1
Upright QR All 5.6 ⁄2 300 A300 500A UL, ULC
1
SR All 5.6 ⁄2 300 A300 500A UL, ULC
1
Pendent QR All 5.6 ⁄2 300 A300 500A UL, ULC
1
SR All 5.6 ⁄2 300 A300 500A UL, ULC
1
Recessed Pendent QR All 5.6 ⁄2 300 A300 500A UL, ULC
PRESSURE

1
SR All 5.6 ⁄2 300 A300 500A UL, ULC
HIGH

1
Horizontal Sidewall QR LH/OH 5.6 ⁄2 300 A300/Q-71 500A UL, ULC
1
SR LH/OH 5.6 ⁄2 300 A300/Q-71 500A UL, ULC
1
Rec. Hor. Sidewall QR LH/OH 5.6 ⁄2 300 A300/Q-71 500A UL, ULC
1
SR LH/OH 5.6 ⁄2 300 A300/Q-71 500A UL, ULC
1
E. C. Sidewall QR LH 5.6 ⁄2 300 A300 QR-EC 500A UL, ULC
1
SR LH 5.6 ⁄2 300 A300 QR 500A UL, ULC
1
Rec. E.C. Sidewall QR LH 5.6 ⁄2 300 A300 QR-EC 500A UL, ULC
1
SR LH 5.6 ⁄2 300 A300 QR 500A UL, ULC
Pendent QR Residential 3.0 – 175 F680 583 UL, ULC, SSL, NYC
QR Residential 4.4 – 175 F983 584 UL, ULC, SSL, NYC
Recessed Pendent QR Residential 3.0 – 175 F680 583 UL, ULC, SSL, NYC
QR Residential 4.4 – 175 F983 584 UL, ULC, SSL, NYC
Concealed Pendent QR Residential 4.2 – 175 F978 584M UL, ULC, SSL, NYC
RESIDENTIAL

Flush Pendent QR Residential 4.2 – 175 F990 586F UL, ULC, SSL, NYC
QR Residential 5.6 – 175 F992 587 UL, ULC, SSL, NYC
Sidewall QR Residential 3.5 – 175 F685 587F UL, ULC, SSL, NYC
QR Residential 5.8 – 175 F687 587M UL, ULC, SSL, NYC
QR Residential 4.4 – 175 F984 587H UL, ULC, SSL, NYC
Recessed Sidewall QR Residential 3.5 – 175 F685 587F UL, ULC, SSL, NYC
QR Residential 5.8 – 175 F687 587M UL, ULC, SSL, NYC
QR Residential 4.4 – 175 F984 587H UL, ULC, SSL, NYC
Flush Sidewall QR Residential 5.6 – 175 F993 591 UL, ULC, SSL, NYC
INST.

1
Pendent QR All 5.6 ⁄2 175 G100 575A UL, C-UL
Sidewall QR LH/OH 5.6 12
⁄ 175 G102 575F UL, C-UL
1
Upright QR All 5.6 ⁄2 175 F960 551 UL, ULC, FM, NYC
1
SR All 5.6 ⁄2 175 F960 552 UL, ULC, FM, SSL, NYC
1
Pendent QR All 5.6 ⁄2 175 F960 551 UL, ULC, FM, NYC
1
SR All 5.6 ⁄2 175 F960 552 UL, ULC, FM, SSL, NYC
1
Recessed Pendent QR All 5.6 ⁄2 175 F960 551 UL, ULC, FM, NYC
DRY

1
SR All 5.6 ⁄2 175 F960 552 UL, ULC, FM, SSL, NYC
1
Deep Ceiling Pendent QR All 5.6 ⁄2 175 F960 551 UL, ULC, FM, NYC
1
SR All 5.6 ⁄2 175 F960 552 UL, ULC, FM, SSL, NYC
1
Horizontal Sidewall QR LH/OH 5.6 ⁄2 175 F960/Q-46 554 UL, ULC, FM, NYC
1
SR LH/OH 5.6 ⁄2 175 F960/Q-46 555 UL, ULC, FM, NYC
1
E.C. Hor. Sidewall QR LH 5.6 ⁄2 175 F960/Q-48 556 UL, ULC, NYC
SR LH 5.6 1⁄2 175 F960/Q-48 557 UL, ULC, NYC
3
ESFR Pendent QR Storage 14.0 ⁄4 175 ESFR-1 598 UL, ULC, FM, LPC, SSL, VdS, LA, NYC
QR Storage 25.2 – 175 ESFR-25 599 UL, C-UL, FM
1
Intermediate Level QR Storage 5.6, 8.0 ⁄2, 17⁄32 175 A 500M UL, ULC, FM, SSL, NYC
STORAGE

1
QR Storage 5.6 ⁄2 175 FR-1 501 UL, ULC, FM, NYC
17
QR Storage 8.0 ⁄32 175 FR-1 502M UL, ULC, FM
1
SR Storage 5.6, 8.0 ⁄2, 17⁄32 175 A 501M UL, ULC, FM, SSL, NYC
1
SR Storage 5.6 ⁄2 175 D 504 UL, ULC, FM, NYC
5
Large Drop SR Storage 11.2 ⁄8 175 F898 597 FM
5
Extra Large Orifice QR Storage 11.2 ⁄8 175 F892QR 595A UL, C-UL, FM
SR Storage 11.2 5⁄8 175 F892 595 UL, C-UL, FM, SSL, NYC
SPECIAL

1
Conventional QR Special 5.6, 8.0 ⁄2, 17⁄32 175 A 507 UL, ULC, LPC, SSL, VdS, NYC
1
(Old Style) SR Special 5.6, 8.0 ⁄2, 17⁄32 175 A 508M UL, ULC, LPC, SSL, VdS, NYC
1
SR Special 5.6 ⁄2 175 F950 509 UL, ULC, LPC, SSL
SR Special 1.4, 2.8, 5.6, 8.0 1⁄4, 3⁄8, 1⁄2, 17⁄32 175 D 510M UL, ULC, LPC, NYC
(1) Refer to the Technical Data Sheet (TD) for specific information. All versions of a sprinkler may not be listed or approved.
(2) Sprinkler Finish: B=Brass, BB=Bright Brass, C=Chrome, L=Lead Coating, P=Polyester Coating (White is standard), Wh=White,
W=Wax Coating (for 135° to 212°), EOL=Enamel over Lead Coating (286° to 360°).
(3) Escutcheon Finish:C=Chrome, Wh=White, Sp=Special Order any Color.
(4) F850 Wrench for polyester coated sprinkler.
(5) FM approval only with Model F705 Escutcheon.
8
Back
Selection Chart Section 2 of 2
Sprinkler
Temperature, °F(1) Element NPT, Inch Finish(1,2) Wrench Escutcheon(3) Notes TYPE
1
160 Solder ⁄2 C, BB, WH F873 C, WH, SP 16' x 16' - 20' x 20'; Aquarius Flush Style
1
135, 155, 175 3, 5 mm Bulb ⁄2 B, C, P (4) Max. Coverage 16' x 22'

COVERAGE
EXTENDED
3
135, 155, 175 3, 5 mm Bulb ⁄4 B, C, P (4) Max. Coverage 16' x 24'
1
165 Solder ⁄2 B, C F799 Max. Coverage 16' x 20'
3
140, 165 Solder ⁄4 B, C F799 Max. Coverage 16' x 24'
1
135, 155, 175 3, 5 mm Bulb ⁄2 B, C, P F850 Max. Coverage 16' x 22'; Notes: (5,9)
3
135, 155, 175 3, 5 mm Bulb ⁄4 B, C, P F850 C, WH, SP Max. Coverage 16' x 24'; Notes: (5,9)
160 Solder 1⁄2 C, BB, WH F873 C, WH, SP Max. Coverage 14' x 18'; Aquarius Flush Style
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
135, 155, 175, 200 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP Note: (10)

PRESSURE
1
135, 155, 175, 200 5 mm Bulb ⁄2 B, C, P F850 C, WH, SP Note: (10)

HIGH
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2 B, C, P (4)
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2 B, C, P (4)
1
135, 155, 175, 200 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP
1
135, 155, 175, 200 5 mm Bulb ⁄2 B, C, P F850 C, WH, SP
1
135, 155, 175 3 mm Bulb ⁄2 B, C, P (4) Max. Coverage 16' x 22'; Note: (10)
1
135, 155 5 mm Bulb ⁄2 B, C, P (4) Max. Coverage 16' x 24'; Note: (10)
1
135, 155, 175 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP Max. Coverage 16' x 22'; Note: (10)
135, 155 5 mm Bulb 1⁄2 B, C, P F850 C, WH, SP Max. Coverage 16' x 24'; Note: (10)
1
155, 175 3 mm Bulb ⁄2 B, C, P (4) Max. Coverage 20' x 20'
1
155, 175 3 mm Bulb ⁄2 B, C, P (4) Max. Coverage 20' x 20'
1
155, 175 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP Max. Coverage 20' x 20'; Note: (9)
1
155 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP Max. Coverage 20' x 20'; Note: (10)
1
155 3 mm Bulb ⁄2 – F874 C, WH, SP Max. Coverage 20' x 20'; 1⁄2 Adjustment

RESIDENTIAL
1
160 Solder ⁄2 C, BB, WH F873 C, WH, SP Max. Coverage 20' x 20'; Aquarius Flush Style
1
160 Solder ⁄2 C, BB, WH F873 C, WH, SP Max. Coverage 18' x 18'; Aquarius Flush Style
1
155, 175 3 mm Bulb ⁄2 B, C, P (4) Max. Coverage 16' x 16'
1
155 3 mm Bulb ⁄2 B, C, P F799 Max. Coverage 16' x 20'
1
155 3 mm Bulb ⁄2 B, C, P (4) Max. Coverage 16' x 16'
1
155, 175 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP Max. Coverage 16' x 16'; Note: (8)
1
155 3 mm Bulb ⁄2 B, C, P 1948 C, WH, SP Max. Coverage 16' x 16'; Note: (8)
1
155 3 mm Bulb ⁄2 B, C, P F850 C, WH, SP Max. Coverage 16' x 16'; Note: (8)
160 Solder 1⁄2 C, BB, WH F873 C, WH, SP Max. Coverage 14' x 18'; Aquarius Flush Style

INST.
1
135, 155, 175, 200 2.5 mm Bulb ⁄2 C 1509-1, -3 C
135, 155, 175, 200 2.5 mm Bulb 12
⁄ C 1509-1, -3 C
135, 155, 175, 200, 286 3 mm Bulb 1 B, C Adj. Wrench Lengths 5" to 48" in 1⁄2" increments
135, 155, 175, 200, 286, 360 5 mm Bulb 1 B, C Adj. Wrench Lengths 5" to 48" in 1⁄2" increments
135, 155, 175, 200, 286 3 mm Bulb 1 B, C Adj. Wrench C, WH Lengths 2" to 48" in 1⁄2" increments
135, 155, 175, 200, 286, 360 5 mm Bulb 1 B, C Adj. Wrench C, WH Lengths 2" to 48" in 1⁄2" increments
135, 155, 175, 200 3 mm Bulb 1 B, C F870 C, WH Lengths 31⁄2" to 48" in 1⁄4" increments

DRY
135, 155, 175, 200 5 mm Bulb 1 B, C F870 C, WH Lengths 31⁄2" to 48" in 1⁄4" increments
135, 155, 175, 200, 286 3 mm Bulb 1 B, C Adj. Wrench C, WH Lengths 1⁄2" to 46" in 1⁄2" increments
135, 155, 175, 200, 286, 360 5 mm Bulb 1 B, C Adj. Wrench C, WH Lengths 1⁄2" to 46" in 1⁄2" increments
135, 155, 175, 200, 286 3 mm Bulb 1 B, C Adj. Wrench C, WH Lengths 21⁄2" to 48" in 1⁄2" increments
135, 155, 175, 200, 286, 360 5 mm Bulb 1 B, C Adj. Wrench C, WH Lengths 21⁄2" to 48" in 1⁄2" increments
135, 155, 175 3 mm Bulb 1 B, C Adj. Wrench C, WH Lengths 21⁄2" to 48" in 1⁄2" increments
135, 155, 175 5 mm Bulb 1 B, C Adj. Wrench C, WH Lengths 21⁄2" to 48" in 1⁄2" increments
3
165, 214 Solder ⁄4 B F872 35' Storage/ 45' Ceiling
165, 214 Solder 1 B Adj. Wrench 40' Storage/ 45' Ceiling
1
135, 155, 175, 200, 286 3 mm Bulb ⁄2, 3⁄4 B, C Adj. Wrench
STORAGE
1
165 Solder ⁄2 B, C F799
3
165 Solder ⁄4 B, C F799
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2, 3⁄4 B, C Adj. Wrench
1
135, 175, 250 11 mm Bulb ⁄2 W, L F799
3
155, 200, 286 5 mm Bulb ⁄4 B Adj. Wrench
3
135, 155, 175, 200, 286 3 mm Bulb ⁄4 B, C Adj. Wrench
3
135, 155, 175, 200, 286 5 mm Bulb ⁄4 B, C Adj. Wrench
SPECIAL

1
135, 155, 175, 200, 286 3 mm Bulb ⁄2, 3⁄4 B, C, P (4)
1
135, 155, 175, 200, 286, 360 5 mm Bulb ⁄2, 3⁄4 B, C, P (4)
1
165, 212, 286, 350 Solder ⁄2 B, C, L, W, WOL, EOL F799
135, 175, 250, 325, 400, 500 11 mm Bulb 1⁄2, 3⁄4 W, L, WOL, EOL F799
(6) Response: SR=Standard Response, QR=Quick Response
(7) Hazard: LH=Light Hazard, OH=Ordinary Hazard, All= Any Hazard
(8) Separately ordered escutcheon: F705-1⁄2" adj.
(9) Separately ordered escutcheon: F700-3⁄4" adj. or F705-1⁄2" adj.
(10) Separately ordered escutcheon: F700-3⁄4" adj.

9
Back

GEM S TANDARD R ESPONSE SPRINKLERS


Standard response spray sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard installation rules
recognized by the applicable Listing or Approval agency. There are two types of standard response sprinklers – bulb type and solder type.
Universal Model A, Designer, and Quartzoid® bulb type sprinklers are available in a variety of attractive finishes that blend well with their surround-
ings. When in stand-by service, a small bubble in the fluid contained in the bulb compensates for normal temperature changes. When heated, the
fluid in the bulb expands and shatters the bulb which allows water to be discharged. Duraspeed® solder type sprinklers employ a bell-shaped
copper link whose two sections are joined by solder with a predetermined temperature rating. Heat absorbed by the link is conducted directly to the
soldered joint. When the solder melts, the link springs apart, releasing water that strikes the deflector.
Standard response sprinklers are designed for use in essentially all applications including office buildings, libraries, banks, theaters, factories, and
warehouses.

Universal Model A Universal Model A Universal Model A


5 mm Bulb Type, K=2.8 5 mm Bulb Type, K=5.6 5 mm Bulb Type, K=8.0
Pendent and Upright Sprinklers Pendent and Upright Sprinklers Pendent and Upright Sprinklers

◆ Small orifice, standard response, spray ◆ Standard response, spray sprinkler ◆ Large orifice, standard response, spray
sprinkler ◆ Discharges a hemispherical water spray sprinklers
◆ Designed for use in light hazard pattern in the area under the sprinkler ◆ Designed for use in commercial and
occupancies ◆ Small frame, narrow profile bulb industrial applications
◆ Requires less water than standard K=5.6 Orifice Size: 1⁄2" (15 mm) ◆ Higher water discharge rate than K=5.6
orifice sprinkler Temperature Ratings: sprinklers
◆ Pintle provides visual indication that these 135°F/57°C, 155°F/68°C, 175°F/79°C,
sprinklers have an orifice other than K=5.6 ◆ Variety of finishes available to blend with
200°F/93°C, 286°F/141°C, 360°F/182°C surrounding surfaces
Orifice Size: 3⁄8" Thread Size (NPT): 1⁄2"
Temperature Ratings: Orifice Size: 17⁄32" (20 mm)
Maximum Service Pressure: 175 psi (12.1 bar)
135°F/57°C, 155°F/68°C, 175°F/79°C, Temperature Ratings:
Listings and Approvals:
200°F/93°C, 286°F/141°C, 360°F/182°C 135°F/57°C, 155°F/68°C, 175°F/79°C,
ULI, ULC, FM, LPC, SSL and VdS 200°F/93°C, 286°F/141°C, 360°F/182°C
Thread Size (NPT): 1⁄2"
Finishes: Thread Size (NPT): 3⁄4"
Maximum Service Pressure: 175 psi (12.1 bar)
Natural brass, chrome plated, and Maximum Service Pressure: 175 psi (12.1 bar)
Listings and Approvals: polyester coated in any color
ULI, ULC, and FM Listings and Approvals:
Technical Data Sheet: TD516M
(See TD514Q for SSL, LPC and VdS) ULI, ULC, FM, LPC, SSL and VdS
Finishes: Finishes:
Natural brass, chrome plated, and Natural brass, chrome plated, and
polyester coated in any color polyester coated in any color
Technical Data Sheet: TD514M Technical Data Sheet: TD526Q

S TANDARD R ESPONSE SPRINKLERS


10
Back

GEM STANDARD R ESPONSE S PRINKLERS

Universal Model A/Q-71


5 mm Bulb Type, K=5.6 Universal Model A Universal Model A
Horizontal Sidewall Sprinklers 5 mm Bulb Type, K=5.6 5 mm Bulb Type
and Recessed Horizontal Sidewall Vertical Sidewall Sprinkler K=5.6 & K=8.0
Sprinklers Recessed Pendent Sprinklers
◆ The addition of a Model F700 two-piece ◆ Versatile, standard response, sidewall ◆ Model F700 two-piece escutcheon
escutcheon converts the Model A/Q-71 sprinkler converts the 5 mm bulb Model A to a
into an attractive recessed installation ◆ Designed for installation along a wall or on highly attractive standard response,
◆ Small frame, standard response, sidewall the side of a beam just beneath a smooth recessed spray sprinkler
sprinkler ceiling ◆ F700 provides 3⁄4" (19.1 mm) of vertical
◆ Unique deflector design results in smaller ◆ Special deflector can be installed in either adjustment from the flush pendent
profile pendent or upright position position
◆ Designed for installation along a wall or on ◆ Used in lieu of pendent or upright ◆ Adjustment allows flexibility in the
the side of a beam just beneath a smooth sprinklers because of building construction installation of the sprinkler with the drop
ceiling or economic considerations fitting.
◆ Water discharge is directed primarily Orifice Size: 1⁄2" (15mm) Orifice Size:
outward and downward in a quarter 1⁄2" (15mm) (K=5.6) or
Temperature Ratings:
spherical pattern 17⁄32" (20 mm) (K=8.0)
135°F/57°C, 155°F/68°C, 175°F/79°C,
Orifice Size: 1⁄2" (15mm)(k=5.6) 200°F/93°C, 286°F/141°C, 360°F/182°C Temperature Ratings:
Temperature Ratings: Thread Size (NPT): 1⁄2" 135°F/57°C, 155°F/68°C, 175°F/79°C,
135°F/57°C, 155°F/68°C, 175°F/79°C, Maximum Service Pressure: 175 psi (12.1 bar) 200°F/93°C
200°F/93°C, 286°F/141°C, 360°F/182°C Listings and Approvals: Thread Size (NPT): 1⁄2" (K=5.6) or 3⁄4" (K=8.0)
Thread Size (NPT): 1⁄2" ULI and ULC (light and ordinary hazard); Maximum Service Pressure: 175 psi (12.1 bar)
Maximum Service Pressure: 175 psi (12.1 bar) FM (135˚F to 286˚F, light hazard); Listings and Approvals:
Listings and Approvals: LPC, and SSL ULI,ULC, FM SSL, and LPC
ULI and ULC (light and ordinary hazard); Finishes: Finishes:
FM (135˚F to 286˚F, light hazard); Natural brass, chrome plated, and Sprinkler: Natural brass, chrome plated,
SSL, and LPC polyester coated in any color and polyester coated in any color
Finishes: Technical Data Sheet: TD533 Escutcheon: Chrome plated or color coated
Natural brass, chrome plated, and in any color
polyester coated in any color Technical Data Sheet:
Technical Data Sheet: TD535M TD516M (K=5.6) or TD526Q (K=8.0)

11
Back

GEM S TANDARD R ESPONSE SPRINKLERS

Model F692 Designer Issue D Quartzoid® Model F950 Duraspeed®


4 mm Bulb type, K=5.6 K=5.6 K=5.6
Concealed Pendent Sprinkler Pendent and Upright Sprinklers Pendent and Upright Sprinklers

◆ Concealed standard response, spray ◆ Bulb type, standard response, spray ◆ Solder type, standard response, spray
sprinkler sprinkler sprinkler
◆ Enclosed escutcheon plate for use in those ◆ Extra-high and ultra-high temperature ◆ Discharges a hemispherical water spray
applications where aesthetics is a primary ratings and corrosion resistant coatings pattern in the area under the sprinkler
consideration Orifice Size: 1⁄2" (15mm) Orifice Size: 1⁄2"
◆ Separable, two-piece design of the Temperature Ratings: Temperature Ratings:
mounting cup and cover plate allows 135°F/57°C, 155°F/68°C, 175°F/79°C, 165°F/74°C, 212°F/100°C, 286°F/141°C,
installation of the sprinklers and pressure 200°F/93°C, 250°F/121°C, 286°F/141°C, 350°F/177°C
testing of the fire protection system prior 325°F/163°C, 360°F/182°C, 400°F/204°C, Thread Size (NPT): 1⁄2"
to installation of a suspended ceiling or 500°F/260°C, 650°F/343°C
application of the finish coating to a fixed Maximum Service Pressure: 175 psi (12.1 bar)
Thread Size (NPT): 1⁄2" Listings and Approvals:
ceiling
Maximum Service Pressure: 175 psi (12.1 bar) ULI, ULC, FM, LPC, SSL, and VdS
◆ Internally threaded closure with 1⁄2"
(13 mm) of adjustment Listings and Approvals: ULI, ULC, FM, and LPC Finishes:
Orifice Size: 1⁄2" Finishes: Natural brass, chrome plated, lead coated,
Temperature Ratings: Natural brass, chrome plated (400˚F to Corroproof® coated, and Corroproof® over
650˚F). Lead coated (135˚F to 500˚F). lead coated
135°F/57°C, 155°F/68°C, 175°F/79°C,
Corroproof® coated (135˚F to 200˚F). Technical Data Sheet: TD517
200°F/93°C
Corroproof® over lead coated (135˚F to
Thread Size (NPT): 1⁄2" 360˚F)
Maximum Service Pressure: 175 psi (12.1 bar) Technical Data Sheet: TD525M
Listings and Approvals: ULI, ULC and FM
Finishes:
Cover plate standard finishes are chrome
plated and white painted - any color cover
plate paint is available upon request
Technical Data Sheet: TD579Q

12
Back

GEM STANDARD R ESPONSE S PRINKLERS

Model F950 Duraspeed® Model F950/Q-46 Duraspeed®


K=1.4, 2.8, 4.2 K=5.6
Pendent and Upright Sprinklers Horizontal Sidewall Sprinkler

◆ Small orifice, standard response, spray ◆ Solder type, standard response, sidewall
sprinklers sprinkler
◆ Solder type ◆ Designed for installation along a wall or on
◆ Designed for light hazard occupancies the side of a beam just beneath a smooth
requiring less water than a standard 1⁄2" ceiling
orifice sprinkler ◆ Water discharge is directed primarily
◆ A pintle, extending from the deflector, outward and downward in a quarter
provides a visual indication that these spherical pattern; however, a portion is
sprinklers have an orifice size other also directed to the backwall
than 1⁄2" Orifice Size: 1⁄2" (15 mm)
Orifice Size: Temperature Ratings:
1⁄4" (K=1.4), 3⁄8" (K=2.8) & 7⁄16" (K=4.2) 165°F/74°C, 212°F/100°C, 286°F/141°C,
Temperature Ratings: 350°F/177°C
165°F/74°C, 212°F/100°C, 286°F/141°C, Thread Size (NPT): 1⁄2"
350°F/177°C Maximum Service Pressure: 175 psi (12.1 bar)
Thread Size (NPT): 1⁄2" Listings and Approvals:
Maximum Service Pressure: 175 psi (12.1 bar) ULI and ULC (light and ordinary hazard);
Listings and Approvals: FM (light hazard); and, SSL
ULI and ULC. FM (K=2.8 only). Finishes:
Finishes: Natural brass, chrome plated, lead coated,
Natural brass, chrome plated, lead coated, Corroproof® coated, and Corroproof® over
Corroproof® coated, and Corroproof® over lead coated
lead coated Technical Data Sheet: TD536
Technical Data Sheet: TD515

13
Back

GEM Q UICK R ESPONSE SPRINKLERS


Quick response sprinklers are designed with a 3mm bulb to react quicker at the specified temperature. They are available in pendent, upright,
recessed, concealed, vertical sidewall, and horizontal sidewall styles.
The narrow profile bulbs and attractive finishes of the Universal Model A provide specifiers with a wide variety of sprinklers for use in quick
response applications. The Aquarius® Series offers discriminating specifiers the ultimate in a fusible solder type, low profile, flush style design, and
the versatile Quick Response FR Series provides the specifier with a solder type sprinkler for most commercial and industrial applications.

Universal Model A Universal Model A Universal Model A


3 mm Bulb Type, K=2.8 3 mm Bulb Type, K=5.6, 3 mm Bulb Type, K=8.0
Pendent and Upright Sprinklers Pendent and Upright Sprinklers Pendent and Upright Sprinklers

◆ Small orifice, quick response, spray ◆ Quick response, spray sprinkler ◆ Large orifice, quick response, spray
sprinklers ◆ Hemispherical water spray pattern in the sprinklers
◆ Designed for use in light hazard area under the sprinkler ◆ Designed for use in applications requiring
occupancies ◆ Small frame and narrow profile bulb higher water discharge rate than standard
◆ Discharge rate that is approximately 50% enhances their appearance K=5.6 sprinkler
of a standard K=5.6 orifice sprinkler when Orifice Size: 1⁄2" (15 mm) ◆ Commercial and industrial application
flowing at the same pressure Temperature Ratings: Orifice Size: 17⁄32" (20 mm)
◆ A pintle, extending from the deflector, 135°F/57°C, 155°F/68°C, 175°F/79°C, Temperature Ratings:
provides a visual indication that these 200°F/93°C, 286°F/141°C 135°F/57°C, 155°F/68°C, 175°F/79°C,
sprinklers have an orifice other than K=5.6 200°F/93°C, 286°F/141°C
Thread Size (NPT): 1⁄2"
Orifice Size: 3⁄8" Thread Size (NPT): 3⁄4"
Maximum Service Pressure: 175 psi (12.1 bar)
Temperature Ratings: Maximum Service Pressure: 175 psi (12.1 bar)
Listings and Approvals:
135°F/57°C, 155°F/68°C, 175°F/79°C, Listings and Approvals:
ULI, ULC, FM, LPC, SSL, and VdS
200°F/93°C, 286°F/141°C
Finishes: ULI, ULC, FM, LPC, SSL, and VdS
Thread Size (NPT): 1⁄2"
Natural brass, chrome plated, and Finishes:
Maximum Service Pressure: 175 psi (12.1 bar)
polyester coated in any color Natural brass, chrome plated, and
Listings and Approvals: polyester coated in any color
Technical Data Sheet: TD515M
ULI, ULC, and FM (See TD513Q for SSL, Technical Data Sheet: TD525Q
LPC and VdS)
Finishes:
Natural brass, chrome plated, and
polyester coated in any color
Technical Data Sheet: TD513M

QUICK RESPONSE SPRINKLERS


14
Back

GEM Q UICK R ESPONSE S PRINKLERS

Universal Model A/Q-71 Universal Model A


3 mm Bulb Type, K=5.6 Universal Model A 3 mm Bulb Type,
Horizontal Sidewall Sprinkler and 3 mm Bulb Type, K=5.6 K=5.6 & 8.0
Recessed Horizontal Sidewall Vertical Sidewall Sprinkler Recessed Pendent Sprinklers
Sprinkler
◆ The addition of a Model F700 or F705 two- ◆ Versatile, quick response, sidewall ◆ The addition of a Model F700 or F705 two-
piece escutcheon converts the Model sprinkler piece escutcheon converts the 3 mm bulb
A/Q-71 into an attractive recessed ◆ Installed in either the pendent or upright Model A to a highly attractive quick
installation position along a wall or the side of a beam response, recessed spray sprinkler
◆ Offer the features and benefits of quick and just below a smooth ceiling ◆ Model F700 provides 3⁄4" (19.1 mm) of
response ◆ Generally used in lieu of pendent or vertical adjustment from the flush pendent
◆ Designed for use in applications where upright sprinklers because of building position
aesthetics must be considered or where construction or economic considerations ◆ Adjustment allows flexibility in the
building construction makes the installa- Orifice Size: 1⁄2" (15 mm) installation of the sprinkler with a drop
tion of pendent or upright sprinklers Temperature Ratings: fitting
impractical Orifice Size:
135°F/57°C, 155°F/68°C, 175°F/79°C,
Orifice Size: 1⁄2" (15 mm) 200°F/93°C, 286°F/141°C 1⁄2" (15 mm) (K=5.6) &

Temperature Ratings: 17⁄32" (20 mm) (K=8.0)


Thread Size (NPT): 1⁄2"
135°F/57°C, 155°F/68°C, 175°F/79°C, Maximum Service Pressure: 175 psi (12.1 bar) Temperature Ratings:
200°F/93°C, 286°F/141°C 135°F/57°C, 155°F/68°C,
Listings and Approvals:
Thread Size (NPT): 1⁄2" 175°F/79°C, 200°F/93°C
ULI and ULC (light and ordinary hazard);
Maximum Service Pressure: 175 psi (12.1 bar) FM (light hazard); LPC, and SSL Thread Size (NPT): 1⁄2" (K=5.6) & 3⁄4" (K=8.0)
Listings and Approvals: Finishes: Maximum Service Pressure: 175 psi (12.1 bar)
ULI and ULC (light and ordinary hazard); Natural brass, chrome plated, and Listings and Approvals:
FM (light hazard); SSL, and LPC polyester coated in any color ULI, ULC, FM, LPC, and SSL
Finishes: Technical Data Sheet: TD532 Finishes:
Natural brass, chrome plated, and Sprinkler: Natural brass, chrome plated,
polyester coated in any color and polyester coated in any color.
Technical Data Sheet: TD534 Escutcheon: Chrome plated or color coated
in any color
Technical Data Sheet:
TD515M (K=5.6) or TD525Q (K=8.0)

QUICK RESPONSE SPRINKLERS


15
Back

GEM Q UICK R ESPONSE SPRINKLERS

Model F690 Designer Model F995 Aquarius® Model F996 Aquarius®


3 mm Bulb Type, K=5.6 K=5.6 K=5.6
Concealed Pendent Sprinkler Flush Pendent Sprinkler Flush Horizontal Sidewall
Sprinkler

◆ Quick response, spray sprinkler ◆ Low profile, quick response, spray ◆ Low profile, quick response, sidewall
◆ Concealed in an enclosed escutcheon plate sprinkler sprinkler
with flat cover for use in those applications ◆ Designed to be installed in the flush ◆ Designed for installation along a wall or
where aesthetics is a primary consider- pendent position for either new installa- lintel and just beneath a smooth ceiling
ation tions or to replace standard sprinklers to ◆ Escutcheon plates with up to 1⁄2"
◆ Separable, two-piece design of the achieve a more pleasing appearance (12.7 mm) of adjustment that allows
mounting cup and cover plate allows ◆ Escutcheon plates with up to 1⁄2" flexibility during installation
installation of the sprinklers and pressure (12.7 mm) of adjustment that allows Orifice Size: 1⁄2" (15 mm)
testing of the fire protection system prior flexibility during installation Temperature Ratings:
to installation of a suspended ceiling or Orifice Size: 1⁄2" (15 mm) 160°F/71°C, 212°F/100°C
application of the finish coating to a fixed Temperature Ratings:
ceiling Thread Size (NPT): 1⁄2"
160°F/71°C, 212°F/100°C Maximum Service Pressure: 175 psi (12.1 bar)
◆ Internally threaded closure with 1⁄2"
Thread Size (NPT): 1⁄2" Listings and Approvals:
(12.7 mm) of adjustment
Maximum Service Pressure: 175 psi (12.1 bar) ULI, ULC, LPC and SSL
Orifice Size: 1⁄2" (15 mm)
Listings and Approvals: Finishes:
Temperature Ratings:
ULI, ULC, LPC and SSL Sprinkler: Chrome plated, bright brass, or
135°F/57°C, 155°F/68°C, 175°F/79°C,
200°F/93°C Finishes: white
Thread Size (NPT): 1⁄2" Sprinkler: Chrome plated, bright brass, or Escutcheon: Chrome plated, bright brass,
white or color coated in any color
Maximum Service Pressure: 175 psi (12.1 bar)
Escutcheon: Chrome plated or color coated Technical Data Sheet: TD538
Listings and Approvals:
in any color
ULI, ULC and FM (standard response)
Technical Data Sheet: TD520
Finishes:
Cover plates are supplied chrome plated or
with any color factory applied paint
Technical Data Sheet: TD578Q

16
Back

GEM Q UICK R ESPONSE S PRINKLERS

Model FR-1 Fast Response Model FR-1/Q-46 Fast Response Model FR-1 Fast Response
K=2.8 K=5.6 K=5.6
Pendent and Upright Sprinklers Horizontal Sidewall Sprinkler Pendent and Upright Sprinklers
◆ Small orifice, fast response, spray ◆ Designed for compact installation along a ◆ Solder type, fast response, spray sprinkler
sprinklers wall or on the side of a beam just beneath ◆ Typically used in hotels, motels, office
◆ Designed for use in light hazard a smooth ceiling buildings and other commercial and
occupancies requiring less water than is ◆ Generally used in lieu of pendent or industrial applications
discharged from a standard K=5.6 orifice upright sprinklers because of aesthetics, Orifice Size: 1⁄2" (15mm)
sprinkler building construction or economic Temperature Ratings:
◆ A pintle, extending from the deflector, considerations
140°F/60°C, 165°F/74°C, 212°F/100°C
provides a visual indication that these ◆ Can be recessed with GEM’s standard
Thread Size (NPT): 1⁄2"
sprinklers have an orifice other than K=5.6 Model F705 two piece Escutcheon
Maximum Service Pressure: 175 psi (12.1 bar)
Orifice Size: 3⁄8" Orifice Size: 1⁄2" (15 mm)
Listings and Approvals:
Temperature Ratings: Temperature Ratings:
ULI, ULC, FM, LPC, SSL, and VdS
140°F/60°C, 165°F/74°C, 212°F/100°C 140°F/60°C, 165°F/74°C, 212°F/100°C
Finishes:
Thread Size (NPT): 1⁄2" Thread Size (NPT): 1⁄2"
Sprinkler: Natural brass and chrome plated
Maximum Service Pressure: 175 psi (12.1 bar) Maximum Service Pressure: 175 psi (12.1 bar)
Technical Data Sheet: TD516
Listings and Approvals: ULI and ULC Listings and Approvals:
Finishes: ULI and ULC (light and ordinary hazard);
Natural brass and chrome plated FM (light hazard); and SSL
Technical Data Sheet: TD514 Finishes:
Natural brass and chrome plated
Technical Data Sheet: TD535

Model FR-1 Model FR-1


Fast Response Fast Response
K=2.8 & 5.6 K=8.0
Recessed Pendent Pendent and
Sprinkler Upright Sprinklers

◆ The addition of a Model F705 two-piece escutcheon converts the ◆ Large orifice, solder type spray sprinkler
FR-1 to an attractive recessed spray sprinkler ◆ Provides approximately 50% greater water discharge
Orifice Size: 3⁄8" (K=2.8) & 1⁄2" (15 mm) (K=5.6) than standard K=5.6 orifice sprinkler
Temperature Ratings: Orifice Size: 17⁄32" (20 mm)
140°F/60°C, 165°F/74°C, 212°F/100°C Temperature Ratings:
Thread Size (NPT): 1⁄2" 140°F/60°C, 165°F/74°C, 212°F/100°C
Maximum Service Pressure: 175 psi (12.1 bar) Thread Size (NPT): 3⁄4"
Listings and Approvals: Maximum Service Pressure: 175 psi (12.1 bar)
ULI and ULC Listings and Approvals:
Finishes: ULI, ULC, FM, and SSL
Sprinkler: Natural brass and chrome plated Finishes:
Escutcheon: Chrome plated or color coated in any color Natural brass and chrome plated
Technical Data Sheet: TD514 (K=2.8) or TD516 (K=5.6) Technical Data Sheet: TD526

17
Back

GEM EXTENDED C OVERAGE SPRINKLERS


Extended coverage (EC) sprinklers, unless otherwise noted, are for the protection of light hazard occupancies. They are intended for the protection
of areas larger than those specified in standard installation rules. Extended coverage sprinklers are available in both standard response (EC) and
quick response (QR-EC). They are available in pendent, horizontal sidewall, and recessed horizontal sidewall. These sprinklers are typically used in
hotels, restaurants, office buildings, and any other large open area where it is desirable to either have one sprinkler per room or to reduce the
overall number of required sprinklers.

Universal Model A Universal Model A


3 and 5 mm Bulb Type 3 and 5 mm Bulb Type Model F992 Aquarius®
K=5.6 & 8.0 K=5.6 & 8.0 K=5.6
EC and QR-EC EC and QR-EC Recessed EC and QR-EC Flush
Horizontal Sidewall Sprinklers Horizontal Sidewall Sprinklers
◆ Install along a wall or beam and just ◆ Model F700 or F705 two-piece escutcheon ◆ Low profile, solder type sprinkler
beneath a smooth level ceiling converts Model A EC and QR-EC sidewall ◆ Designed to be installed in the flush
◆ EC and QR-EC coverage areas up to sprinklers into low profile sprinkler pendent position
16' x 22' (4.9 m x 6.7 m) assemblies with coverage areas up to ◆ Intended for EC coverage areas up to
◆ Among the most water-efficient extended 16' x 22' (4.9 m x 6.7 m) for K=5.6 and 20' x 20' (6.1 m x 6.1 m) or
coverage sprinklers 16' x 24' (4.9 m x 7.3 m) for K=8.0 QR-EC coverage areas up to 16' x 16'
Orifice Size: ◆ F700 provides 3⁄4" (19.1 mm) of horizontal (4.9 m x 4.9 m)
1⁄2" (15mm) (K=5.6) & adjustment from the flush sidewall ◆ Escutcheon plates with up to 1⁄2"
17⁄32" (20 mm) (K=8.0) position (12.7 mm) of vertical adjustment that
Temperature Ratings: Orifice Size: allows flexibility during installation
1⁄2" (15mm)(K=5.6) &
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C Orifice Size: 1⁄2" (15mm)
17⁄32" (20 mm)(K=8.0)
Thread Size (NPT): 1⁄2" (K=5.6) & 3⁄4" (K=8.0) Temperature Ratings: 160˚F/71˚C
Temperature Ratings: Thread Size (NPT): 1⁄2"
Maximum Service Pressure: 175 psi (12.1 bar)
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C Maximum Service Pressure: 175 psi (12.1 bar)
Listings and Approvals: ULI, ULC, FM and SSL
Thread Size (NPT): 1⁄2" (K=5.6) & 3⁄4" (K=8.0) Listings and Approvals: ULI, ULC, and SSL
Finishes:
Maximum Service Pressure: 175 psi (12.1 bar) Finishes:
Natural brass, chrome plated, and
Listings and Approvals: ULI, ULC, and SSL Sprinkler: Chrome plated, bright brass, or
polyester coated in any color
Technical Data Sheet: Finishes: white
Sprinkler: Natural brass, chrome plated, Escutcheon: Chrome plated or color coated
TD545 (K=5.6) or TD547 (K=8.0)
and polyester coated in any color in any color
Escutcheon: Chrome plated or color coated Technical Data Sheet: TD587
in any color
Technical Data Sheet:
TD545 (K=5.6) or TD547 (K=8.0)

18
Back

GEM EXTENDED C OVERAGE SPRINKLERS

Model F993 Model FR-1 Fast


Aquarius® Response
K=5.6 K=5.6 & 8.0 Orifice
EC and QR-EC Flush EC and QR-EC
Horizontal Sidewall Horizontal Sidewall
Sprinkler Sprinklers

◆ Low profile, solder type sprinkler ◆ Solder type, extended coverage horizontal sidewall sprinklers
◆ Nominal K-Factor of 5.6 provide versatility for light hazard extended coverage areas
◆ Install in flush horizontal sidewall position just below a smooth level ceiling ◆ K=5.6 for QR-EC coverage areas up to 16' x 20' (4.9 m x 6.1 m)*
◆ EC coverage areas up to 14' x 18' (4.3 m x 5.5 m) and and 18' x 16' (5.5 m x 4.9 m)
QR-EC coverage areas up to 14' x 16' (4.3 m x 4.9 m) ◆ K=8.0 for EC and QR-EC coverage areas up to 16' x 24'
◆ Escutcheon plates with up to 1⁄2" (12.7 mm) of horizontal adjustment (4.9 m x 7.3 m)*
reduce position accuracy ◆ QR-EC coverage areas up to 20' x 16' (6.1 m x 4.9 m)
Orifice Size: 1⁄2" (15mm) Orifice Size:
1⁄2" (15mm) (K=5.6) & 17⁄32" (20 mm) (K=8.0)
Temperature Ratings: 160˚F/71˚C
Thread Size (NPT): 1⁄2" Temperature Ratings:
Maximum Service Pressure: 175 psi (12.1 bar) 165°F/74°C (K=5.6) & 140˚F/60˚C, 165˚F/74˚C (K=8.0)
Listings and Approvals: ULI, ULC, and SSL. Thread Size (NPT): 1⁄2" (K=5.6) & 3⁄4" (K=8.0)
Finishes: Maximum Service Pressure: 175 psi (12.1 bar)
Sprinkler: Chrome plated, bright brass, or white. Listings and Approvals: ULI, and ULC; *FM; SSL; and VdS (K=5.6)
Escutcheon: Chrome plated, or color coated in any color Finishes: Natural brass and chrome plated
Technical Data Sheet: TD591 Technical Data Sheet: TD588 (K=5.6) or TD589 (K=8.0)
* FM approved for 16' x 20' coverage area only.

Model F890 Model F895


K=8.0, & 11.2 K=11.4 & 14.5
Extended Coverage Extended Coverage
Light Hazard Ordinary Hazard
Pendent and Upright, Pendent,
Recessed Pendent and Recessed
Sprinklers Pendent Sprinklers
◆ Low profile, glass bulb style, pendent spray sprinkler ◆ Nominal 11.4 K-Factor designed for coverage applications of
14' x 14' (4.3 m x 4.3 m) and 16' x 16' (4.9 m x 4.9 m)
◆ Nominal 8.0 K-Factor with 3⁄4" NPT & 11.2 K-Factor 3/4" N.P.T.
◆ Nominal 14.5 K-Factor designed for coverage applications of
◆ Light hazard occupancies and coverages to 20' x 20' (6.1 m x 6.1 m) 16' x 16' (4.9 m x 4.9 m) to 20' x 20' (6.1 m x 6.1 m)
◆ Pendent heads can be recessed using GEM’s standard Model F705 ◆ Low profile glass bulb spray sprinklers
two piece escutcheon assembly ◆ Both have 3⁄4" NPT
Orifice Size: 17⁄32" (K=8.0) & 5⁄8" (K=11.2) ◆ Pendent sprinklers can be recessed using GEM’s standard Model
Temperature Ratings: F700 two piece Escutcheon assembly
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200°F/93°C Orifice Size: 5⁄8" (K=11.4) & 3⁄4" (K=14.5)
Thread Size (NPT): 3⁄4" Temperature Ratings:
Maximum Service Pressure: 175 psi (12.1 bar) 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200˚F/93˚C, 286˚F/182˚C
Listings and Approvals: Thread Size (NPT): 3⁄4"
Pendent: UL, C-UL, and FM Maximum Service Pressure: 175 psi (12.1 bar)
Recessed Pendent: UL, C-UL, and FM Listings and Approvals:
Finishes: Pendent and Upright: UL, C-UL, FM, and SSL.
Recessed Pendent: UL, C-UL, and SSL
Sprinkler: Natural brass, chrome plated and polyester coated in any color.
Finishes:
Escutcheon: Chrome plated or color coated in any color
Sprinkler: Natural brass, chrome plated, lead coated, and polyester
Technical Data Sheet: TD594 (K=8.0) & TD 594m (K=11.2) coated in any color.
Escutcheon: Chrome plated or color coated in any color
Technical Data Sheet: TD596A

19
Back

GEM RECESSED A ND C ONCEALED SPRINKLERS


Recessed sprinklers provide an attractive, recessed design along with a pleasing appearance for applications such as offices and retail settings.
The design also allows the sprinkler system to be installed, tested, and evaluated prior to installation or finishing of a ceiling or wall. Escutcheon
plates, available for these sprinklers, feature different ranges of adjustability for easy and neat installation after completion of the ceiling work.
Concealed sprinklers combine aesthetics with fire protection. The heart of the concealed assembly is a small-framed sprinkler head contained
within an attractive enclosure that blends with the ceiling for an unobtrusive and pleasing appearance. The cover plate assembly consists of an
enclosure and a cover plate that is soldered to the enclosure at three equidistant points around its periphery.

Universal Model A Model F692 Designer Model FR-1


5 mm Bulb Type, K=5.6 & 8.0, 4 mm Bulb Type, K=5.6 K=2.8 & 5.6
Standard Response Standard Response Quick Response
Recessed Pendent Sprinklers Concealed Pendent Sprinkler Recessed Pendent Sprinklers

◆ The addition of a Model F700 two-piece ◆ Standard response , spray sprinkler ◆ Recessed versions of the FR-1 solder type
escutcheon converts the 5 mm bulb Model concealed in an enclosed escutcheon plate sprinklers
A pendent to a highly attractive standard with flat cover for use in those applications ◆ Recessed versions use GEM’s standard
response, recessed spray sprinkler where aesthetics is a primary consideration Model F705, two piece escutcheon
◆ The F700 provides 3⁄4" (19.1 mm) of ◆ The separable, two-piece design of the assembly
vertical adjustment from the flush pendent mounting cup and cover plate allows ◆ Use of the K=2.8 orifice is limited to light
position installation of the sprinklers and pressure hazard occupancies
◆ Adjustment allows flexibility in the testing of the fire protection system prior
Orifice Size:
installation of the sprinkler with a drop to installation of a suspended ceiling or
3⁄8" (K=2.8) & 1⁄2" (15 mm) (K=5.6)
fitting application of the finish coating to a fixed
ceiling Temperature Ratings:
Orifice Size:
1⁄2" (15mm) (K=5.6) & ◆ Features an internally threaded closure 140˚F/60˚C, 165˚F/74˚C, 212˚F/100˚C
17⁄32" (20 mm) (K=8.0) with 1⁄2" (12.7 mm) of adjustment Thread Size (NPT): 1⁄2"
Temperature Ratings: Orifice Size: 1⁄2" (15mm) Maximum Service Pressure: 175 psi (12.1 bar)
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, Temperature Ratings: Listings and Approvals: ULI and ULC
200˚F/93˚C 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, Finishes:
Thread Size (NPT): 200˚F/93˚C Sprinkler: Natural brass or chrome plated
1⁄2" (K=5.6) & 3⁄4" (K=8.0) Thread Size (NPT): 1⁄2" Escutcheon: Chrome plate or color coated
Maximum Service Pressure: 175 psi (12.1 bar) Maximum Service Pressure: 175 psi (12.1 bar) in any color
Listings and Approvals: Listings and Approvals: Technical Data Sheet:
ULI, ULC, FM, SSL, and LPC ULI, ULC, and FM TD514 (K=2.8) or TD516 (K=5.6)
Finishes: Finishes:
Sprinkler: Natural brass, chrome plated, Cover plates are supplied chrome plated or
and polyester coated in any color with any color factory applied paint
Escutcheon: Chrome plated or color coated Technical Data Sheet: TD579Q
in any color
Technical Data Sheet:
TD516M (K=5.6) or TD526Q (K=8.0)

20
Back

GEM R ECESSED A ND C ONCEALED S PRINKLERS

Model F690 Designer Universal Model A Universal Model A


3 mm Bulb Type, K=5.6 3 mm Bulb Type, K=5.6 & 8.0 3 and 5 mm Bulb Type
Quick Response Quick Response K=5.6 & 8.0
Concealed Pendent Sprinkler Recessed Pendent Sprinklers EC and QR-EC, Recessed
Horizontal Sidewall Sprinklers
◆ Quick response, spray sprinkler concealed ◆ The addition of a Model F700 or Model ◆ Addition of a Model F700 or Model F705*
in an enclosed escutcheon plate with flat F705* two-piece escutcheon converts the two-piece escutcheon converts the Model
cover for use in those applications where 3 mm bulb Model A to a highly attractive A EC and QR-EC sidewall sprinklers into
aesthetics is a primary consideration quick response, recessed spray sprinkler highly attractive, low profile sprinkler
◆ Separable, two-piece design of the ◆ Model F700 provides 3⁄4" (19.1 mm) of assemblies with coverage areas up to
mounting cup and cover allows installation vertical adjustment from the flush pendent 16' x 22' (4.9 m x 6.7 m) for the K=5.6,
of the sprinklers and pressure testing of position and 16' x 24' (4.9 m x 7.3 m) for K=8.0
the fire protection system prior to ◆ Model F705 provides 1⁄2" (12.7 mm) of ◆ Model F700 provides 3⁄4" (19.1 mm) of
installation of a suspended ceiling or vertical adjustment from the flush pendent horizontal adjustment from the flush
application of the finish coating to a fixed position sidewall position
ceiling ◆ Adjustment allows flexibility in the ◆ Model F705 provides 1⁄2" (12.7 mm) of
◆ Internally threaded closure with installation of the sprinkler with a drop horizontal adjustment from the flush
1⁄2" (12.7 mm) of adjustment sidewall position
fitting
Orifice Size: 1⁄2" (15mm) Orifice Size: Orifice Size:
Temperature Ratings: 1⁄2" (15 mm) (K=5.6) & 1⁄2" (15 mm) (K=5.6) &
17⁄32" (20 mm) (K=8.0) 17⁄32" (20 mm) (K=8.0)
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C,
200˚F/93˚C Temperature Ratings: Temperature Ratings:
Thread Size (NPT): 1⁄2" 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C
Maximum Service Pressure: 175 psi (12.1 bar) 200˚F/93˚C Thread Size (NPT):
Listings and Approvals: Thread Size (NPT): 1⁄2" (K=5.6) & 3⁄4" (K=8.0)

ULI, ULC and FM as standard response 1⁄2" (K=5.6) & 3⁄4" (K=8.0) Maximum Service Pressure: 175 psi (12.1 bar)
Finishes: Maximum Service Pressure: 175 psi (12.1 bar) Listings and Approvals:
Cover plates are supplied chrome plated or Listings and Approvals: ULI, ULC, FM and SSL
with any color factory applied paint ULI, ULC, FM, SSL and LPC Finishes:
Technical Data Sheet: TD578Q Finishes: Sprinkler: Natural brass, chrome plated,
Sprinkler: Natural brass, chrome plated, and polyester coated in any color
and polyester coated in any color Escutcheon: Chrome plated or color coated
Escutcheon: Chrome plated or color coated in any color
in any color Technical Data Sheet:
Technical Data Sheet: TD545 (K=5.6) or TD547 (K=8.0)
TD515M (K=5.6) or TD525Q (K=8.0)

21
Back

GEM SPECIAL PURPOSE SPRINKLERS


Special purpose sprinklers are intended for use in specific applications, including the protection of high-piled storage, freezing and areas subject to
corrosion. Also, these installations may need consideration for more water at lower pressures, more water over a greater area. The model F927 on-
off sprinkler can be used for high value areas where there is an increased requirement to minimize potential water damage.

Model ESFR-1, K=14.3, and Model F892 and F892QR


Model F927 Designer
Model ESFR-25™, K=25.2 Designer, K=11.2
K=5.6
Early Suppression Fast Response Standard and Quick Response
Flow Control
(ESFR) Pendent Sprinklers Extra Large Orifice (ELO)
On-Off Pendent Sprinkler
Upright Sprinklers

◆ Designed for use in the protection of high- ◆ Discharge rate approximately 60% greater
◆ Utilizes a 5 mm bulb to seal the sprinkler
piled storage than K=8.0 sprinklers and approximately
outlet and a temperature sensitive
100% greater than K=5.6 sprinklers when
◆ Eliminates many of the requirements for bimetallic disc to control water flow
flowing at the same rate
in-rack sprinklers ◆ Ideal for applications where water
◆ Ideal for use in high density applications
◆ Materials may be stored up to 40 feet discharge, either during a fire or from
such as the protection of high-piled
(12.2 m) high, in buildings up to 45 feet accidental damage is a concern
storage since high flow rates can be
(13.7 m) ◆ A flush mount escutcheon providing up to produced at lower pressures
◆ ESFR-1 and ESFR-25 sprinklers use the 1" (25.4 mm) of vertical adjustment is
Orifice Size: 5⁄8"
principles of direct attack on burning fuel available to provide an aesthetically
by improved heavy sprinkler discharge pleasing, low profile installation Temperature Ratings:
◆ Patented frame design substantially ◆ Bimetallic disc cycles water on and off as 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C
reduces the frame shadow effects that necessary to control fire 200˚F/93˚C, 286˚F/141˚C
often produce non-uniformity in spray Orifice Size: 1⁄2" (15 mm) Thread Size (NPT): 3⁄4"
pattern Temperature Ratings: Maximum Service Pressure: 175 psi (12.1 bar)
◆ Novel orifice seal and unique fast response 135˚F/57˚C, 175˚F/79˚C Listings and Approvals:
link design make the ESFR-1 and ESFR-25 UL, C-UL, FM, and SSL
Thread Size (NPT): 1⁄2"
the very latest in sprinkler technology Finishes:
Maximum Service Pressure: 175 psi (12.1 bar)
Orifice Size: Natural brass and chrome plated
3⁄4" (ESFR-1) & 1" (ESFR-25)
Listings and Approvals:
FM, and SSL. Technical Data Sheet:
Temperature Ratings: TD595 (F892) or TD595A (F892QR)
Finishes:
165˚F/74˚C, 214˚F/101˚C
Sprinkler: Natural brass or chrome plated
Thread Size (NPT):
3⁄4" (ESFR-1) & 1" (ESFR-25)
Escutcheon: Chrome plated or white color
coated
Maximum Service Pressure: 175 psi (12.1 bar)
Technical Data Sheet: TD560
Listings and Approvals:
ESFR-1: ULI, ULC, FM, SSL, LPC, and VdS
ESFR-25: FM (Others pending)
Finishes:
Natural brass
Technical Data Sheet:
TD598 (ESFR-1) or TD599 (ESFR-25)

22
Back

GEM SPECIAL PURPOSE SPRINKLERS

Model F960 Designer Model F960/Q-48 Designer


Model F960/Q-46 Designer
Bulb Type, K=5.6 Bulb Type, K=5.6
Bulb Type, K=5.6
Standard or Quick Response Standard Response
Standard or Quick Response
Dry Pendent Extended Coverage
Dry Horizontal Sidewall Sprinkler
Dry Recessed Pendent and Dry Horizontal Sidewall Sprinkler
Dry Upright Sprinklers
◆ Bulb type sprinkler with an escutcheon ◆ Bulb type sprinkler with an escutcheon up
◆ Bulb type sprinkler with an escutcheon provides up to 1" (25.4 mm) of horizontal to 1" (25.4 mm) of horizontal adjustment
which provides up to 1" (25.4 mm) of adjustment ◆ Lengths up to 48" (1220 mm)
horizontal adjustment ◆ Designed for use in light hazard occupancy
◆ Lengths up to 48" (1220 mm)
◆ Lengths to 48" (1220 mm) applications requiring a dry sprinkler to
◆ Designed for use in applications requiring
◆ Designed for use in applications where dry sprinklers, or where building construc- cover areas up to 16' x 20' (4.9 m x 6.1 m)
sprinklers and/or connecting piping may tion or aesthetic considerations make the or 18' x 16' (5.5 m x 4.9 m)
be exposed to freezing conditions, or the installation of dry horizontal sidewall ◆ Special assembly provides a seal at the
sprinkler system is seasonally drained sprinklers more desirable than the dry main pipe to prevent water from entering
◆ Special assembly provides a seal at the pendent type. the sprinkler assembly until the sprinkler
main pipe to prevent water from entering ◆ Special assembly provides a seal at the operates
the sprinkler assembly until the sprinkler main pipe to prevent water from entering Orifice Size: 1⁄2" (15 mm)
operates the sprinkler assembly until the sprinkler Temperature Ratings: 135˚F/57˚C, 155˚F/68˚C
◆ Available in pendent, recessed pendent and operates Thread Size (NPT): 1"
upright configurations
Orifice Size: 1⁄2" (15 mm) Maximum Service Pressure: 175 psi (12.1 bar)
Orifice Size: 1⁄2" (15 mm)
Temperature Ratings: Listings and Approvals: ULI and ULC
Temperature Ratings: 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C Finishes:
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C 200˚F/93˚C, 286˚F/141˚C, 360˚F/182˚C
200˚F/93˚C, 286˚F/141˚C, 360˚F/182˚C Sprinkler: Natural brass or chrome
Thread Size (NPT): 1" Technical Data Sheet: TD557
Thread Size (NPT): 1" Maximum Service Pressure: 175 psi (12.1 bar)
Maximum Service Pressure: 175 psi (12.1 bar) Listings and Approvals:
Listings and Approvals: ULI and ULC (light and ordinary hazard)
SR: ULI, ULC, FM, and SSL FM (light hazard)
QR: ULI, ULC, and FM Finishes:
Finishes: Sprinkler: Natural brass or chrome plated
Sprinkler: Natural brass or chrome plated Escutcheons: Chrome plate or color coated
Escutcheons: Chrome plated or color in any color
coated in any color Technical Data Sheet:
Technical Data Sheet: TD554 (QR) or TD555 (SR)
TD551 (QR) or TD552 (SR)

23
Back

GEM SPECIAL PURPOSE SPRINKLERS

Model G100 Model G102


Tamper-Resistant Tamper-Resistant
GemGuard™ GemGuard™
Quick Response Quick Response
K=5.6, Institutional K=5.6, Institutional
Pendent Sprinkler Sidewall Sprinkler
◆ Designed to provide maximum solutions to the unique fire protec- ◆ Designed to provide maximum solutions to the unique fire protec-
tion needs of institutional facilities tion needs of institutional facilities
◆ Vandalizing, moving, or disassembling the GemGuard sprinkler ◆ Vandalizing, moving, or disassembling the GemGuard sprinkler
results in activation and a water flow alarm results in activation and a water flow alarm
◆ Ideal for use in correctional, detention, and mental health care ◆ Ideal for use in correctional, detention, and mental health care
facilities facilities
◆ 175 psi (12.1 bar) ◆ 175 psi (12.1 bar)
◆ Low breakaway weight ◆ Low breakaway weight
◆ Flush mount escutcheons ◆ Flush mount escutcheons
Orifice Size: 1⁄2" Orifice Size: 1⁄2"
Temperature Ratings: 135°F/57°C, 155°F/68°C, 175°F/79°C, 200°F/93°C Temperature Ratings: 135°F/57°C, 155°F/68°C, 175°F/79°C, 200°F/93°C
Thread Size (NPT): 1⁄2" NPT Thread Size (NPT): 1⁄2" NPT
Maximum Service Pressure: 175 psi (12.1 bar) Maximum Service Pressure: 175 psi (12.1 bar)
Listings and Approvals: UL and C-UL Listed Listings and Approvals: UL and C-UL Listed
Finishes: Chrome-plated finish Finishes: Chrome-plated finish
Technical Data Sheet: TD575A Technical Data Sheet: TD575F

24
Back

GEM SPECIAL PURPOSE SPRINKLERS

Model F890 Designer Model F898 Designer


Extended Coverage, K=8.0 & 11.2 K=11.2, Upright, Large Drop Sprinkler
Light Hazard, Pendent Sprinkler

◆ Designed for use in automatic sprinkler systems for the protection ◆ Designed for the protection of high piled storage
of light hazards up to a maximum coverage area of 400ft2 ◆ Can provide a higher level of protection than standard spray
◆ Recessed version is obtained by combining the pendent sprinkler sprinklers
with the Model F705 recessed escutcheon (3/4") ◆ Can provide an advantage by eliminating in-rack sprinklers
◆ Rated for use at a maximum service pressure of 175 psi (12.1 bar) ◆ 175 psi (12.1 bar)
Orifice Size: 17⁄32" (K=8.0) & 5⁄8" (K=11.2) Orifice Size: 5⁄8"
Temperature Ratings: 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200°F/93°C Temperature Ratings: 155˚F/68˚C, 200°F/93°C, 286°F/141°C
Thread Size (NPT): 3⁄4" Thread Size (NPT): 3⁄4"
Maximum Service Pressure: 175 psi (12.1 bar) Maximum Service Pressure: 175 psi (12.1 bar)
Listings and Approvals: UL and C-UL Listed Listings and approvals:
Finishes: Approved by Factory Mutual Research Corporation
Sprinkler: Natural Brass, White Polyester, Chrome Plated Finishes:
Escutcheon: Chrome Plated, White Color Coated Natural brass finish
Technical Data Sheet: TD594 (K=8.0), & TD594M (K=11.2) Technical Data Sheet: TD597

Type 316
Stainless Steel
Bulb Type, K=5.6,
Pendent and Upright
Sprinklers

◆ Designed for use in applicable corrosive environments. Refer


questions on applicable corrosive environments to the Technical
Data department.
◆ Features Type 316 stainless steel metallic components and a
frangible bulb element
Orifice Size: 1⁄2" (K=5.6)
Temperature Ratings: 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200°F/93°C
Thread Size (NPT): 1⁄2"
Maximum Service Pressure: 175 psi (12.1 bar)
Listings and Approvals: UL and C-UL Listed
Technical Data Sheet: TD581M
25
Back

GEM I NTERMEDIATE L EVEL (RACK S TORAGE) S PRINKLERS


Intermediate level, or storage sprinklers, are designed for use in rack storage sprinkler systems, where their thermally sensitive elements must be
shielded from the water spray of higher elevation sprinklers which could operate during a fire. Intermediate Level Sprinklers are also used in
applications such as beneath open gridded catwalks. These sprinklers are intended for use in fire sprinkler systems designed in accordance with
the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA requirements).

Universal Model A, Standard Response FR-1, Quick Response


Bulb Type, K=5.6 & 8.0, Bulb Type, K=5.6 & 8.0,
Intermediate Level (Rack Storage) Intermediate Level (Rack Storage)
Pendent and Upright Sprinklers Pendent and Upright Sprinklers
Orifice Size: 1⁄2" (k=5.6), 17⁄32" (k=8.0) Orifice Size: 1⁄2" (k=5.6), 17⁄32" (k=8.0)
Temperature Ratings: Temperature Ratings:
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200˚F/93˚C, 286˚F/141˚C, 165˚F/74˚C
360˚F/182˚C Thread Size (NPT): 1⁄2" (k=5.6), 3⁄4" (k=8.0)
Thread Size (NPT): 1⁄2" (k=5.6), 3⁄4" (k=8.0) Maximum Service Pressure: 175 psi (12.1 bar)
Maximum Service Pressure: 175 psi (12.1 bar) Listings and Approvals:
Listings and Approvals: ULI, ULC, and FM
ULI, ULC, FM, and SSL Finishes:
Finishes: Natural brass and chrome plated.
Natural brass and chrome plated. Technical Data Sheet: TD501 (k=5.6), TD502M (k=8.0)
Technical Data Sheet: TD501M

Universal Model A, Quick Response


Bulb Type, K=5.6 & 8.0,
Intermediate Level (Rack Storage)
Pendent and Upright Sprinklers
Orifice Size: 1⁄2" (k=5.6), 17⁄32" (k=8.0)
Temperature Ratings:
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200˚F/93˚C, 286˚F/141˚C
Thread Size (NPT): 1⁄2" (k=5.6), 3⁄4" (k=8.0)
Maximum Service Pressure: 175 psi (12.1 bar)
Listings and Approvals:
ULI, ULC, FM, and SSL
Finishes:
Natural brass and chrome plated.
Technical Data Sheet: TD500M

26
Back

GEM CONVENTIONAL (OLD S TYLE) S PRINKLERS


Conventional sprinklers can be installed either pendent or upright position. In either position they produce a spherical water discharge pattern with
approximately 50% of the discharge directed upwards and approximately 50% of the discharge directed downward. Conventional sprinklers are
generally used as required by the automatic sprinkler system installation rules of the country and authority having jurisdiction. NFPA permits the use
of “Old Style Sprinklers” where special construction features require a unique water distribution; for the protection of fur vaults; or, the replacement
of similar sprinklers that had been installed prior to 1955.

Universal Model A Universal Model A


Standard Response Quick Response
K=5.6 & 8.0 K=5.6 & 8.0
Conventional Conventional
(Old Style) (Old Style)
Sprinklers Sprinklers

Orifice Size: 1⁄2" (k=5.6), 17⁄32" (k=8.0) Orifice Size: 1⁄2" (k=5.6), 17⁄32" (k=8.0)
Temperature Ratings: Temperature Ratings:
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200˚F/93˚C, 286˚F/141˚C, 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200˚F/93˚C, 286˚F/141˚C
360˚F/182˚C Thread Size (NPT): 1⁄2" (k=5.6), 3⁄4" (k=8.0)
Thread Size (NPT): 1⁄2" (k=5.6), 3⁄4" (k=8.0) Maximum Service Pressure: 175 psi (12.1 bar)
Maximum Service Pressure: 175 psi (12.1 bar) Listings and Approvals: ULI, ULC, LPC, and SSL and VdS
Listings and Approvals: ULI, ULC, LPC, SSL and VdS Finishes:
Finishes: Natural brass and chrome plated and polyester coated in any color.
Natural brass, chrome plated and polyester coated in any color. Technical Data Sheets: TD507
Technical Data Sheets: TD508M

F950 Issue D
Standard Response Standard Response
K=5.6 K=1.4, 2.8, 5.6, 8.0
Conventional Conventional
(Old Style) (Old Style)
Sprinklers Sprinklers

Orifice Size: 1⁄2" (k=5.6) Orifice Size: 1⁄4" (k=1.4), 3⁄8" (k=2.8), 1⁄2" (k=5.6),17⁄32" (k=8.0)
Temperature Ratings: Temperature Ratings:
165˚F/74˚C, 212˚F/100˚C, 286˚F/141˚C, 350˚F/9177˚C 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, 200˚F/93˚C, 250˚F/121˚C, 286˚F/
Thread Size (NPT): 1⁄2" (k=5.6) 141˚C, 325˚F/163˚C, 360˚F/182˚C, 400˚F/204˚C, 500˚F/260˚C
Maximum Service Pressure: 175 psi (12.1 bar) Thread Size (NPT): 1⁄2" (k=1.4, 2.8, 5.6), 3⁄4" (k=8.0)
Listings and Approvals: ULI, ULC, LPC, SSL and LPC Maximum Service Pressure: 175 psi (12.1 bar)
Finishes: Listings and Approvals: ULI, ULC, and LPC (k=5.6)
Natural brass and chrome plated. Also available in lead coated, Finishes:
Corroproof® coated, and Corroproof® over lead coated Natural brass and chrome plated. Also available in lead coated,
Technical Data Sheets: TD509 Corroproof® coated, and Corroproof® over lead coated
Technical Data Sheets: TD510M

27
Back

GEM R ESIDENTIAL SPRINKLERS


The diverse line of residential sprinklers are aesthetically pleasing and among the most water usage efficient in the fire protection industry.
Residential sprinklers are available in pendent, recessed pendent, concealed pendent, horizontal sidewall, recessed horizontal sidewall, flush
pendent, and flush horizontal sidewall. A residential sprinkler used in protection of homes, dwellings, apartments, etc. requires a high wall wetting
capability in addition to an approved floor coverage, in order to be listed as a residential sprinkler per NFPA 13D, residential occupancies up to four
stories in height per NFPA 13R, and the residential portions of any occupancy per NFPA 13. The performance characteristics associated with
residential sprinklers have been proven to help in the control of residential type fires.

Model F685 Designer, Model F687


Model F680 Designer,
K=3.5, Low Flow Bulb Type, K=5.8
K=3.0, Low Flow
Residential Horizontal Sidewall Residential Horizontal Sidewall
Residential Pendent and
and Recessed Horizontal Sidewall and Recessed Horizontal Sidewall
Recessed Pendent Sprinkler
Sprinkler Sprinkler
◆ Fast responding automatic bulb type ◆ Fast responding automatic bulb sprinkler
◆ Bulb type residential sprinkler which can
sprinkler designed for installation along a designed for installation along a wall or
be recessed using GEM’s standard Model
wall or lintel and just beneath a smooth, lintel just beneath a smooth, level ceiling
F700 or F705 two-piece escutcheon
level ceiling ◆ Can be recessed with GEM’s standard
assembly
◆ Minimal water flows for coverages from Model F705 two piece escutcheon
◆ Industry leading minimal water flows for
12' x 12' (3.7 m x 3.7 m) to assembly
coverages from 12' x 12' (3.7 m x 3.7 m)
16' x 16' (4.9 m x 4.9 m) ◆ For coverages of 12' x 12' (3.7 m x 3.7 m),
to 20' x 20' (6.1 m x 6.1 m)
◆ Can be recessed with GEM’s standard 16' x 18' (4.9 m x 5.5 m) and
◆ May be used as a high adjustment
Model F705 two piece escutcheon 16' x 20' (4.9 m x 6.1 m)
sprinkler with the Model F700 two piece
assembly Orifice Size: 1⁄2" (K=5.8)
escutcheon providing up to 3⁄4" (19.1 mm)
of adjustment from the fully exposed Orifice Size: (K=3.5) Temperature Ratings: 155˚F/68˚C
pendent position Temperature Ratings: 155˚F/68˚C, 175˚F/79˚C Thread Size (NPT): 1⁄2"
Orifice Size: (K=3.0) Thread Size (NPT): 1⁄2" Maximum Service Pressure: 175 psi (12.1 bar)
Temperature Ratings: 155˚F/68˚C, 175˚F/79˚C Maximum Service Pressure: 175 psi (12.1 bar) Listings and Approvals: UL, ULC, and SSL
Thread Size (NPT): 1⁄2" Listings and Approvals: ULI, ULC, and SSL Finishes:
Maximum Service Pressure: 175 psi (12.1 bar) Finishes: Standard: chrome plated and white
Listings and Approvals: ULI, ULC, and SSL Standard: chrome plated and white polyester: any color polyester upon
Finishes: polyester: any color polyester upon request (Sprinklers and Escutcheons)
request (Sprinklers and Escutcheons) Technical Data Sheet: TD587M
Standard: chrome plated and white
polyester: any color polyester upon Technical Data Sheet: TD587F
request (Sprinklers and Escutcheons)
Technical Data Sheet: TD583

28
Back

GEM R ESIDENTIAL S PRINKLERS

Model F983 Designer Model F984 Designer Model F978 Designer


Bulb Type, K=4.4 Bulb Type, K=4.4 Bulb Type, K=4.2
Residential Pendent and Recessed Residential Horizontal Sidewall Residential Pendent
Pendent Sprinklers and Recessed Horizontal Sidewall Concealed Sprinkler
Sprinklers
◆ Fast responding bulb sprinkler for ◆ Fast responding bulb sprinkler ◆ Bulb type residential pendent concealed
residential coverage areas up to 20' x 20' ◆ For installation along a wall or lintel and sprinkler with a coverage area 12' x 12' to
(6.1 m x 6.1 m) just beneath a smooth, level ceiling 20' x 20'
◆ Can be recessed in GEM’s standard Model ◆ Can be recessed using GEM's standard ◆ For use in those applications where
F700 two piece escutcheon assembly Model F705 two piece escutcheon aesthetics are a primary consideration
◆ May also be used as a high adjustment assembly ◆ The small cover plate is flat and blends
sprinkler with F700 closure providing up to ◆ May also be used as a high adjustment well with the ceiling
3⁄4" (19.1 mm) of adjustment from the fully sprinkler with the closure providing up to ◆ Separable two-piece design provides
exposed pendent position 1⁄2" (12.7 mm) of adjustment from the 1⁄2" (12.7 mm) of vertical adjustment

◆ Available at the ordinary temperature flush sidewall position ◆ Screw type engagement of the mounting
rating of 155˚F/68˚C, as well as in the ◆ Suitable for sidewall coverage areas up to plate position will not change in relation to
intermediate temperature rating of 175˚F/ 16' x 16' (4.9 m x 4.9 m) the ceiling
79˚C for use with ambient temperatures up Orifice Size: 7⁄16" (k=4.4) Orifice Size: 7⁄16" (k=4.2)
to 150˚F/66˚C with coverage areas up to Temperature Ratings: 155˚F/68˚C Temperature Ratings: 155˚F/68˚C
14' x 14' (4.3 m x 4.3 m)
Thread Size (NPT): 1⁄2" Thread Size (NPT): 1⁄2"
Orifice Size: 7⁄16" (k=4.4)
Maximum Service Pressure: 175 psi (12.1 bar) Maximum Service Pressure: 175 psi (12.1 bar)
Temperature Ratings: 155˚F/68˚C, 175˚F/79˚C*
Listings and Approvals: ULI, ULC and SSL Listings and Approvals: UL, ULC, and SSL
Thread Size (NPT): 1⁄2"
Finishes: Finishes:
Maximum Service Pressure: 175 psi (12.1 bar)
Sprinkler: Chrome plated, natural brass, Cover plates are supplied with a satin
Listings and Approvals: ULI, ULC, and SSL and polyester coated in any color chrome finish or with any color factory
Finishes: Escutcheon: Chrome plated or polyester applied paint
Sprinkler: Chrome plated, natural brass, coated in any color Technical Data Sheet: TD584M
and polyester coated in any color Technical Data Sheet: TD587H
Escutcheon: Chrome plated or polyester
coated in any color
Technical Data Sheet: TD584
*w/o Recessed Escutcheon

29
Back

GEM R ESIDENTIAL SPRINKLERS

Model F990 Aquarius® Model F992 Aquarius® Model F993 Aquarius®


Solder Type, K=4.2 Solder Type, K=5.6 Solder Type, K=5.6
Residential Flush Pendent Residential Flush Pendent Residential Flush Horizontal
Sprinkler Sprinkler Sidewall Sprinkler

◆ Aesthetically pleasing flush design ◆ Attractive flush design ◆ Good looking, low profile sprinkler
◆ Designed to be installed in the flush ◆ Designed to be installed in the flush designed for installation along a wall or
pendent position for residential coverage pendent position for residential coverage lintel and just below a smooth, level ceiling
areas up to 20' x 20' (6.1 m x 6.1 m) areas up to 18' x 18' (5.5 m x 5.5 m) ◆ Designed to be installed in the flush
◆ Escutcheon plates with up to 1⁄2" (12.7 ◆ Escutcheon plates with up to 1⁄2" (12.7 sidewall position for residential coverage
mm) of vertical adjustment allows mm) of vertical adjustment allows areas up to 14' x 14' (4.3 m x 4.3 m)
flexibility during installation flexibility during installation ◆ Escutcheon plates with up to 1⁄2" (12.7
Orifice Size: 7⁄16" (k=4.2) Orifice Size: 1⁄2" (k=5.6) mm) of horizontal adjustment allows
flexibility during installation
Temperature Ratings: 160˚F/71˚C Temperature Ratings: 160˚F/71˚C
Orifice Size: 1⁄2" (k=5.6)
Thread Size (NPT): 1⁄2" Thread Size (NPT): 1⁄2"
Temperature Ratings: 160˚F/71˚C
Maximum Service Pressure: 175 psi (12.1 bar) Maximum Service Pressure: 175 psi (12.1 bar)
Thread Size (NPT): 1⁄2"
Listings and Approvals: ULI, ULC, and SSL Listings and Approvals: ULI, ULC, and SSL
Maximum Service Pressure: 175 psi (12.1 bar)
Finishes: Finishes:
Listings and Approvals: ULI, ULC, and SSL
Sprinkler: Chrome plated, bright brass, or Sprinkler: Chrome plated, bright brass, or
white white Finishes:
Escutcheon: Chrome plated or color coated Escutcheon: Chrome plated or color coated Sprinkler: Chrome plated, bright brass, or
in any color in any color white
Technical Data Sheet: TD586F Technical Data Sheet: TD587 Escutcheon: Chrome plated or color coated
in any color
Technical Data Sheet: TD591

30
Back

GEM R ESIDENTIAL S PRINKLERS


Residential Sprinkler Head Performance Chart
F983 F984 F990 F992 F993 F978 F680 F685 F687
Flush
Horizontal Flush Flush Horizontal Horizontal Horizontal
Pendent Sidewall Pendent Pendent Sidewall Concealed Pendent Sidewall Sidewall
Nominal K-Factor 4.4 (63.4) 4.4 (63.4) 4.2 (60.5) 5.6 (80.7) 5.6 (80.7) 4.2 (60.5) 3.0 (43.2) 3.5 (50.4) 5.8 (83.5)

Temperature Rating 155˚F/68˚C 155˚F/68˚C 160˚F/71˚C 160˚F/71˚C 160˚F/71˚C 155˚F/68˚C 155˚F/68˚C 155˚F/68˚C 155˚F/68˚C
175˚F/79˚C 175˚F/79˚C 175˚F/79˚C

Thread Size 1⁄2" 1⁄2" 1⁄2" 1⁄2" 1⁄2" 1⁄2" 1⁄2" 1⁄2" 1⁄2"

Maximum Service 175 PSI 175 PSI 175 PSI 175 PSI 175 PSI 175 PSI 175 PSI 175 PSI 175 PSI
Pressure (12.1 BAR) (12.1 BAR) (12.1 BAR) (12.1 BAR) (12.1 BAR) (12.1 BAR) (12.1 BAR) (12.1 BAR) (12.1 BAR)
Flow (Pressure) For 155°F (68°C) or 160°F (71°C) Temperature Rated Sprinklers, As Applicable
Coverage Areas F983 F984 F990 F992 F993 F978 F680 F685 F687
12' x 12' 12 GPM 13 GPM 12 GPM 17 GPM 22 GPM 16 GPM 9 GPM 12 GPM 18 GPM
One Sprinkler (7.4 PSI) (8.7 PSI) (8.2 PSI) (9.2 PSI) (15.4 PSI) (14.5 PSI) (9 PSI) (11.8 PSI) (9.6 PSI)

12' x 12' 12 GPM 12 GPM 11.5 GPM 15 GPM 15.5 GPM 12 GPM 8 GPM 11 GPM 15.5 GPM
Multiple Sprinklers (7.4 PSI) (7.4 PSI) (7.5 PSI) (7.2 PSI) (7.7 PSI) (8.2 PSI) (7.1 PSI) (9.9 PSI) (7.4 PSI)

14' x 14' 15 GPM 21 GPM 14 GPM 20 GPM 30 GPM 16 GPM 10 GPM 13 GPM
One Sprinkler (11.6 PSI) (22.8 PSI) (11.1 PSI) (12.8 PSI) (28.7 PSI) (14.5 PSI) (11.1 PSI) (13.8 PSI)

14' x 14' 12 GPM 15 GPM 11.5 GPM 17 GPM 21 GPM 12 GPM 8 GPM 12 GPM
Multiple Sprinklers (7.4 PSI) (11.6 PSI) (7.5 PSI) (9.2 PSI) (14.1 PSI) (8.2 PSI) (7.1 PSI) (11.8 PSI)

16' x 16' 15GPM 21 GPM 16 GPM 22 GPM 16 GPM 10 GPM 16 GPM


One Sprinkler (11.6 PSI) (22.8 PSI) (14.5 PSI) (15.4 PSI) (14.5 PSI) (11.1 PSI) (20.9 PSI)

16' x 16' 12 GPM 15 GPM 12 GPM 19 GPM 12 GPM 8 GPM 14 GPM


Multiple Sprinklers (7.4 PSI) (11.6 PSI) (8.2 PSI) (11.5 PSI) (8.2 PSI) (7.1 PSI) (16 PSI)

16' x 18' 28 GPM


One Sprinkler (23.3 PSI)

16' x 18' 23 GPM


Multiple Sprinklers (15.7 PSI)

16' x 20' 29 GPM


One Sprinkler (25 PSI)

16' x 20' 26 GPM


Multiple Sprinklers (20.1 PSI)

18' x 18' 18 GPM 18 GPM 31 GPM 24 GPM 13 GPM


One Sprinkler (16.7 PSI) (18.4 PSI) (30.6 PSI) (32.7 PSI) (18.8 PSI)

18' x 18' 14 GPM 14 GPM 24 GPM 17 GPM 10.5 GPM


Multiple Sprinklers (10.1 PSI) (11.1 PSI) (18.4 PSI) (16.4 PSI) (12.3 PSI)

20' x 20' 20 GPM 22 GPM 25 GPM 14 GPM


One Sprinkler (20.7 PSI) (27.4 PSI) (35.4 PSI) (21.8 PSi)

20' x 20' 17 GPM 18 GPM 18 GPM 13.5 GPM


Multiple Sprinklers (14.9 PSI) (18.4 PSI) (18.4 PSI) (20.3 PSI)

31
Back

GEM H IGH P RESSURE - S TANDARD R ESPONSE S PRINKLERS


High Pressure Sprinklers are intended for areas having a maximum service pressure in excess of the traditional 175 psi (12.1 bar). Their maximum
rated service pressure of 300 psi (20.7 bar) makes them an excellent choice for applications that otherwise would require the use of a pressure
control valve.
Available in either standard or quick response and in either standard or extended coverage, one of the most common applications for high pressure
sprinklers is in fire protection systems for high rise buildings.

Universal Model A300 Universal Model A300/Q-71 Universal Model A300 EC


5 mm Bulb Type, K=5.6 5 mm Bulb Type, K=5.6 5 mm Bulb Type, K=5.6
Pendent, Upright and Horizontal Sidewall and Extended Coverage, Horizontal
Recessed Pendent Sprinklers Recessed Horizontal Sidewall Sidewall and Recessed
Sprinklers Horizontal Sidewall Sprinklers
◆ Standard response, spray sprinkler ◆ Standard response, spray sprinkler ◆ Standard response, spray sprinkler
◆ Standard coverage ◆ Standard coverage ◆ Extended coverage
◆ Discharges a hemispherical water spray ◆ Designed for installation along a wall or on ◆ Designed for installation along a wall or on
pattern in the area under the sprinkler the side of a beam just beneath a smooth the side of a beam just beneath a smooth
◆ Small frame, narrow profile bulb ceiling ceiling
◆ Model F700 two-piece escutcheon ◆ Water discharge is directed primarily ◆ Coverage areas up to 16' x 22'
converts the Model A300 to an attractive outward and downward in a quarter (4.9 m x 6.7 m)
recessed spray sprinkler spherical pattern ◆ Small frame, narrow profile bulb
Orifice Size: 1⁄2" (15 mm) ◆ Small frame, narrow profile bulb ◆ Model F700 two-piece escutcheon
Temperature Ratings: ◆ Model F700 two-piece escutcheon converts the Model A300 EC to an
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, converts the Model A300/Q-71 to an attractive recessed spray sprinkler
200˚F/93˚C, 286˚F/141˚C*, 360˚F/182˚C* attractive recessed spray sprinkler Orifice Size: 1⁄2" (15 mm)
Thread Size (NPT): 1⁄2" Orifice Size: 1⁄2" (15 mm) Temperature Ratings: 135˚F/57˚C, 155˚F/68˚C
Maximum Service Pressure: 300 psi (20.7 bar) Temperature Ratings: Thread Size (NPT): 1⁄2"
Listings and Approvals: UL and ULC 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, Maximum Service Pressure: 300 psi (20.7 bar)
200˚F/93˚C, 286˚F/141˚C*, 360˚F/182˚C* Listings and Approvals: UL and ULC
Finishes:
Thread Size (NPT): 1⁄2" Finishes:
Sprinkler: Natural brass, chrome plated,
and polyester coated in any color Maximum Service Pressure: 300 psi (20.7 bar) Sprinkler: Natural brass, chrome plated,
Escutcheon: Chrome plated or polyester Listings and Approvals: ULI and ULC and polyester coated in any color
coated in any color Finishes: Escutcheon: Chrome plated or polyester
Technical Data Sheet: TD500A Sprinkler: Natural brass, chrome plated, coated in any color
*w/o Recessed Escutcheon and polyester coated in any color Technical Data Sheet: TD500A
Escutcheon: Chrome plated or polyester
coated in any color
Technical Data Sheet: TD500A
*w/o Recessed Escutcheon

32
Back

GEM H IGH P RESSURE - Q UICK R ESPONSE S PRINKLERS

Universal Model A300 Universal Model A300/Q-71 Universal Model A300 QR-EC
3 mm Bulb Type, K=5.6 3 mm Bulb Type, K=5.6 3 mm Bulb Type, K=5.6
Pendent, Upright, and Horizontal Sidewall and Extended Coverage, Horizontal
Recessed Pendent Sprinklers Recessed Horizontal Sidewall Sidewall and Recessed Horizontal
Sprinklers Sidewall Sprinklers

◆ Quick response, spray sprinkler ◆ Quick response, spray sprinkler ◆ Quick response, spray sprinkler
◆ Standard coverage ◆ Standard coverage ◆ Extended coverage
◆ Discharges a hemispherical water spray ◆ Designed for installation along a wall or on ◆ Designed for installation along a wall or on
pattern in the area under the sprinkler the side of a beam just beneath a smooth the side of a beam just beneath a smooth
◆ Small frame, narrow profile bulb ceiling ceiling
◆ Model F700 two-piece escutcheon ◆ Water discharge is directed primarily ◆ Coverage areas up to 16' x 22'
converts the Model A300 to an attractive outward and downward in a quarter (4.9 m x 6.7 m)
recessed spray sprinkler spherical pattern ◆ Small frame, narrow profile bulb
Orifice Size: 1⁄2" (15 mm) ◆ Small frame, narrow profile bulb ◆ Model F700 two-piece escutcheon
Temperature Ratings: ◆ Model F700 two-piece escutcheon converts the Model A300 QR-EC to an
135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, converts the Model A300/Q-71 to an attractive recessed spray sprinkler
200˚F/93˚C, 286˚F/141˚C attractive recessed spray sprinkler Orifice Size: 1⁄2" (15 mm)
Thread Size (NPT): 1⁄2" Orifice Size: 1⁄2" (15 mm) Temperature Ratings:
Maximum Service Pressure: 300 psi (20.7 bar) Temperature Ratings: 135˚F/57˚C, 155˚F/68˚C
Listings and Approvals: UL and ULC 135˚F/57˚C, 155˚F/68˚C, 175˚F/79˚C, Thread Size (NPT): 1⁄2"
Finishes: 200˚F/93˚C, 286˚F/141˚C Maximum Service Pressure: 300 psi (20.7 bar)
Sprinkler: Natural brass, chrome plated, Thread Size (NPT): 1⁄2" Listings and Approvals: UL and ULC
and polyester coated in any color Maximum Service Pressure: 300 psi (20.7 bar) Finishes:
Escutcheon: Chrome plated or polyester Listings and Approvals: UL and ULC Sprinkler: Natural brass, chrome plated,
coated in any color Finishes: and polyester coated in any color
Technical Data Sheet: TD500A Sprinkler: Natural brass, chrome plated, Escutcheon: Chrome plated or polyester
and polyester coated in any color coated in any color
Escutcheon: Chrome plated or polyester Technical Data Sheet: TD500A
coated in any color
Technical Data Sheet: TD500A

33
Back

GEM A QUAMIST® S YSTEMS


The Aquamist® Systems utilize the newest and most unique types of nozzles developed for fire protection. These systems, in some cases, offer an
alternative to higher density automatic sprinkler systems, or an alternative to Halon and other gaseous agents such as carbon dioxide, or fixed
water spray systems.
The mechanisms by which the AquaMist nozzle spray act to extinguish a fire can be a combination of the following factors,
depending on the hazard:
◆ Heat extraction from the fire as water is converted into vapor and the fuel is cooled
◆ Reduced oxygen levels as the water vapor displaces oxygen near the fire
◆ Dilution of flammable vapors by the entrainment of water vapor, to such an extent that the resultant mixture of vapor will not burn
◆ Direct impingement wetting and cooling of the combustibles
◆ Enveloping of the protected area to pre-wet adjacent combustibles, cool gases and other fuels in the area, as well as to block the transfer
of radiant heat to adjacent combustibles

AquaMist OH-2 System Utilizing AquaMist, K=0.24 AquaMist, K=0.24


Type AM24 AquaMist, K=0.64 Total Compartment Deluge Total Compartment Deluge
Automatic Nozzles System Utilizing Type AM4 System Utilizing Type AM10
AquaMist Open Nozzles AquaMist Open Nozzles

◆ Wet pipe or preaction system ◆ Deluge system ◆ Deluge system


◆ Light Hazard or Ordinary Hazard ◆ Protection of flammable liquid hazards ◆ Protection of flammable liquid hazards
(Groups 1 or 2) (UL/FM) ◆ Ceiling height: maximum 24'7" (7.5 m)
◆ Ceiling height: maximum 8'2" (2.5 m) for ◆ Protection of gas turbines (FM) ◆ Nozzle pressure: 170 to 250 psi
OH-1 and OH-2; maximum 10'0" (3.0 m) ◆ Ceiling height: maximum 26'3" (8 m) (11.7 to 17.2 bar)
for LH ◆ Nozzle pressure: 185 to 250 psi ◆ Nozzle coverage: maximum 86 ft2 (8 m2)
◆ Nozzle pressure: 102 to 250 psi (12.8 to 17.2 bar) ◆ Compartment volume: maximum
(7.0 to 17.2 bar) ◆ Nozzle coverage: maximum 172 ft2 (16 m2) 42,345 ft3 (1,200 m3)
◆ Nozzle coverage: maximum 65.3 ft2 ◆ Compartment volume: Listings and Approvals: UL and FM
(6.25 m2) UL - 56,500 ft3 (1,600 m3) Technical Data Sheet: TD1174
Temperature ratings: FM - 45,203 ft3 (1,280 m3)
135°F/57°C, 155˚F/68˚C, 175˚F/79˚C Listings and Approvals: UL and FM
200°F/93°C Technical Data Sheet: TD1173
Listings and Approvals: UL
Technical Data Sheet: TD1172

34
Back

GEM AQUAMIST® S YSTEMS

Model F517 Model VSG Model F446


Ready-Riser® Riser Check Valve Low Flow Automatic Resetting
Waterflow Detector Deluge Valve

◆ Maximum service pressure of 250 psi ◆ Maximum service pressure of 450 psi ◆ Maximum service pressure of 250 psi
(17.2 bar) (31 bar) (17.2 bar)
◆ Suitable for AquaMist LH and OH Systems ◆ Suitable for providing electric alarms upon ◆ Suitable for use as an automatic water
◆ Used in conjunction with Model VSG waterflow in AquaMist LH and OH Systems control valve in AquaMist Total
Waterflow Detector ◆ Minimum flow of 3 GPM (11.4 LPM) for Compartment Deluge Systems
◆ Trim provides appropriate drain valve and alarm ◆ Intended for use with electric fire detection
water gauges ◆ Used in conjunction with Model F517 system
◆ Available in 2" through 8" (50mm through “Ready-Riser” Riser Check Valve ◆ 21⁄2" (65 mm) right angle type valve that
200 mm) sizes ◆ Available in 2" through 4" (50mm through may be installed with discharge outlet
Listings and Approvals: UL, ULC and FM 100 mm) sizes facing left or right
Technical Data Sheet: Listings and Approvals: UL Listings and Approvals: UL, ULC, FM, and VdS
TD104A and TD104B Technical Data Sheet: TD200C Technical Data Sheet: TD114M

35
Back

GEM SPRAY N OZZLES


Spray nozzles are designed for use in a variety of special hazards applications. Their uses include, but are not limited to, exposure protection, fire
control, fire extinguishment, and explosion prevention. Many types of nozzles may be required to provide a properly designed special hazard fire
protection system.

Type EA-1 Type D3 Type D3 Large Capacity


K=1.4, 2.8 & 5.6 K=1.2, 1.8, 2.3, 3.0, 4.1, 5.6 & 7.2 K=10.7, 13.5, 16.4 & 18.1
Protectospray® Nozzle Protectospray® Nozzle Protectospray® Nozzle

◆ Bulb type frangible element for use in ◆ Open orifice design type for use in deluge ◆ Large open orifice design type for use in
closed head systems systems deluge systems
◆ Discharges a filled cone of water droplets ◆ Nozzles are external deflector type nozzles Thread Size (NPT): 1"
at relatively low velocity that discharge a filled cone of water Orifice Sizes and Nominal K-factors:
Thread Size (NPT): 1⁄2" droplets at relatively low velocity No. 39 10.7 (154.1)
Temperature Ratings: Thread Size (NPT): 1⁄2" No. 44 13.5 (194.4)
135˚F/57˚C 325˚F/163˚C Orifice Sizes and Nominal K-factor: No. 48 16.4 (236.2)
175˚F/79˚C 400˚F/204˚C No. 16 1.2 (17.3) No. 50 18.1 (260.6)
250˚F/121˚C 500˚F/260˚C No. 18 1.8 (25.9) Included Angles of Discharge Pattern:
Included Angles of Discharge Pattern: No. 21 2.3 (33.1) 65˚ 110˚ 160˚
65˚ 110˚ 160˚ No. 24 3.0 (43.2) 80˚ 125˚ 180˚
80˚ 125˚ 180˚ No. 28 4.1 (59.0) 95˚ 140˚
95˚ 140˚ No. 32 5.6 (80.6) Materials and Finishes:
Materials and Finishes: No. 34 7.2 (103.7) Natural brass, chrome plated, electroless
Natural brass finish or chrome plated Included Angles of Discharge Pattern: nickel plated, lead coated or Teflon* coated
finish in 135˚F/57˚C through 500˚F/57˚C; 65˚ 110˚ 160˚ Listings and Approvals: ULI and ULC
Corroproof® or lead coated in 135˚F/57˚C 80˚ 125˚ 180˚ Technical Data Sheet: TD620B
and 175˚F/79˚C 95˚ 140˚
Listings and Approvals: ULI, ULC, FM, and SSL Materials and Finishes:
Technical Data Sheet: TD610A Natural brass, chrome plated, electroless
nickel plated, lead coated or Teflon*
coated. Stainless steel, plain only
Listings and Approvals: ULI, ULC, FM, and SSL
Technical Data Sheet: TD620A

36
Back

GEM SPRAY N OZZLES

Type HV (High Velocity) Cooling Tower Nozzles Models F822 through F834
K=1.6, 1.8, 2.9, 4.3, 5.5 & 6.0 K=2.9, Types 1 and 2 K=2.3, 2.6, 2.7, 4.6 & 5.1
Spray Nozzles Mulsifyre® Nozzles
◆ Open, directional spray nozzles ◆ Intended for use in fire protection systems ◆ Open, internal scroll type nozzles
◆ Designed for use in fixed water spray fire for cross flow cooling towers with ◆ Designed to discharge a filled cone of
protection systems where a high velocity combustible fill sections water droplets at a relatively high velocity
water application is needed, such as the ◆ Open nozzle design for use in water spray ◆ Used in either open or water primed
protection of flammable liquids, electrical deluge system systems
transformers, circuit breakers, oil-fired ◆ Installed under the distribution basin, they ◆ A blow-off cap is used with the nozzle for a
boilers and lube oil systems discharge water in a relatively narrow, primed system
◆ Available in six different orifice sizes elongated spray pattern Thread Size: 3⁄4" NPT
◆ Produces a solid conical spray pattern ◆ Type 1 has a waterway designed for use in Nominal K-factor and Color Code
Normal K-factor and NPT Size: towers with diffusion desks, Type 2 for
Type Nominal K-factor Color Code
Type Nominal K-factor NPT Connection those without
F822 2.0 (28.8) Yellow
HV-14 1.6 (23.0) 1" Materials and Finishes:
F824 2.3 (33.1) Red
HV-17 1.8 (26.0) 1" Open nozzles are available as “standard
F826 2.7 (38.9 Orange
HV-26 2.9 (41.8) 1" order” with natural brass finish, chrome
plated finish, lead coated, and/ or F828 2.6 (37.4) White
HV-37 4.3 (62.0) 1" F832 4.6 (66.2) Aluminum
Corroproof® coated. Open nozzles are also
HV-45 5.5 (79.2) 1" available in stainless steel as “special F834 5.1 (73.4) Gray
HV-60 6.0 (86.4) 11⁄4" order” Materials and Finishes:
Materials and Finishes: Thread Size: 3⁄4" NPT Models F822 through F824 nozzles are
Natural brass or stainless steel Listings and Approvals: ULI and FM furnished in plain brass. Models F822B
Listings and Approvals: ULI, ULC, FM, and SSL Technical Data Sheet: TD730 through F824B nozzles with blow-off caps
Technical Data Sheet: TD680 are chrome plated brass with Delrin™ caps
having a silicon O-ring seal and a Teflon™
coated retaining ring. Models F822
through F834 nozzles with dust caps are
furnished in chrome plated brass with
EPDM rubber caps
Listing and Approvals:
Mulsifyre Nozzles: ULI, ULC, and FM.
Mulsifyre Nozzles with Dust Cap: ULI, ULC,
and FM. Mulsifyre Nozzles With Blow-off
Cap: ULI and ULC
Technical Data Sheet: TD675
TI-MAX®
Nozzles and
Sprinklers

◆ Unique discharge devices are made from titanium and can be used
in offshore and other marine applications
◆ Designed for use where strength, low weight, and salt water
corrosion resistance are required
◆ Medium and high velocity type nozzles are available in various
orifices, as well as standard spray sprinklers in upright and pendent
configurations
◆ Additional information is available by contacting your local GEM
office *E.I. DuPont trademark.

37
Back

GEM ACCESSORIES F OR S PRINKLERS AND N OZZLES


These accessories are for use with the sprinklers and nozzles described in this catalog. For complete specifications, installation instructions, and
ratings (where applicable), please refer to the Technical Data Sheet listed after each product description.

Model F705
Model F937 Sprinkler Guard Model F938 Sprinkler Guard Recessed Escutcheons
◆ Universal design can be used with ◆ Low profile design for use with Model A ◆ Consists of a mounting plate and closure
Model A, F950, and FR-1 sprinklers upright and pendent sprinklers for finished appearance in ceilings or
◆ Fits Upright, Pendent, and Sidewall ◆ Model F938 with Q-76 Water Shield is soffits
(Horizontal and Vertical) Styles available for use in storage racks or ◆ Maximum 1⁄2" (12.7 mm) adjustment from
◆ Model F937 with Q-75 Water Shield is beneath grated mezzanines or other areas fully flush position
available for use in storage racks or requiring the sprinklers to be shielded ◆ Primarily designed for use with Universal
beneath grated mezzanines or other areas from possible discharge from sprinklers Model A quick response sprinklers and the
requiring the sprinklers to be shielded above Designer residential sidewall sprinklers
from possible discharge from sprinklers ◆ Can be used with either 1⁄2" or 3⁄4" NPT ◆ Available for use with 1⁄2" or 3⁄4" NPT
above sprinklers sprinkler heads
◆ Can be used with either 1⁄2" or 3⁄4" NPT Finishes: For details request the Technical Data Sheet
sprinklers Zinc plated (Guard and Q-76 shield) referenced in the individual recessed
Finishes: Listings and Approvals: UL, C-UL, and FM sprinkler description
Zinc plated (Guard and Q-75 shield) Finishes:
Listings and Approvals: UL, C-UL, and FM Standard: Chrome plated or white. Color
coated in all colors available

Model F700
Recessed Escutcheons

◆ Consists of a mounting and closure plate for finished appearance in ceilings


◆ Maximum 3⁄4" (19.1 mm) adjustment from fully flush position
◆ Primarily designed for use with Universal Model A Sprinklers and the
Designer residential pendent sprinklers
◆ Prongs on the Mounting Plate are compressed back into the Mounting Plate
as the closure is pushed over it, maintain a tight friction fit between the two
pieces
◆ Available for use with either 1⁄2" or 3⁄4" NPT sprinklers
For details request the Technical Data Sheet referenced in the individual
recessed sprinkler description
Finishes:
Standard: Chrome plated or white. Color coated in all colors available

38
Back

GEM ACCESSORIES F OR S PRINKLERS AND N OZZLES

Model F740 Automatic Sprinkler Escutcheon Plates Model F819


Reserve Supply Cabinets Pendent & Sidewall Sprinklers Rupture Disc Assemblies
◆ Provide for storage of spare sprinklers ◆ Used to improve the overall appearance of ◆ Used in preprimed systems to retain the
◆ Available in six- or twelve-sprinkler the sprinkler installation by concealing the priming water in the piping to open nozzles
capacities clearance holes required for wall or ceiling ◆ Available with 3⁄4" NPT female x 1" NPT
◆ Provide storage for the sprinkler wrench installation male x 3⁄4" NPT female connections
◆ Storage will aid in the prompt replacement ◆ Available in three basic styles: Listings and Approvals: UL
of operated or damaged sprinklers and – standard, one-piece, non-adjustable Technical Data Sheet: TD871
return of fire protection system to service – flush, two-piece, adjustable
as soon as possible – deep, two-piece, adjustable
Technical Data Sheet: TD825 – available for 1⁄2" and 3⁄4" NPT
Finishes:
Chrome plated or white painted
Technical Data Sheet: TD805

Sprinkler Wrenches

◆ Available in different models for use with the various types of sprinklers:
– flush sprinklers
– recessed sprinklers in fixed and suspended ceiling installations
– solder and bulb type sprinklers
– concealed sprinklers
– among others
Technical Data Sheet:
TD820 or see the individual sprinkler Technical Data Sheet

39
Back

GEM WET P IPE S PRINKLER S YSTEMS


Wet pipe sprinkler systems are designed for use in applications where the temperature is maintained above freezing. In such systems each line is
fully pressurized so that water is discharged from a sprinkler head immediately after actuation.
Alarm check valves or water flow detectors are used to actuate local and remote alarms. Typical applications would include heated warehouses,
factories, hospitals, stores, shopping centers and residential settings such as apartment or condominium complexes, and single family residences.

Models F20, F200, and F2001


Resi-Riser® Model F517 Alarm Valves with or without
Pre-Assembled Sprinkler Riser Ready-Riser® Riser Check Valve Model F211 Retard Chamber
(shown with F211)
◆ Compact, pre-assembled, ready to install ◆ Available in 2" through 8" (65mm through ◆ Models F20 (Groove x Groove),
sprinkler riser 200 mm) sizes F200 (Flange x Flange), and
◆ Brass construction for use in potable water ◆ Designed for installation in wet pipe F2001 (Flange x Groove) Alarm Valves are
supply sprinkler systems divided seat ring, rubber-faced clapper,
◆ Available in 1"-2" (25-50 mm) sizes ◆ When used in conjunction with a vane type check type, water flow alarm valves
◆ Integral test and drain assembly, flow water flow detector, it provides an ◆ For use in wet pipe (automatic sprinkler)
switch with retard mechanism, 300 psi economical means of activating electric fire protection system
gauge, and check valve alarms, upon the actuation of one or more ◆ Automatically actuates electrically and/or
◆ Compact size allows for easy installation sprinklers hydraulically operated alarms when there
between 2" x 4" studs in wall ◆ Trim consists of a drain, appropriately is a steady flow equivalent to the discharge
sized to comply with the requirements of rate for one or more sprinklers
◆ Molded mounting points allow for fast and
easy left or right hand installation NFPA 13 and 13R, along with gauges and ◆ The 21⁄2" (65 mm) Alarm Valves may be
connections to monitor supply and system installed vertically
◆ Available with or without pressure relief
valve or flow switch retard mechanism pressures ◆ The 4", 6", and 8" (100mm, 150mm, and
features ◆ Use of 21⁄2", 4", 6", or 8" (65mm, 100mm, 200mm) Alarm Valves may be installed
150mm, or 200 mm) Model F52 grooved vertically or horizontally
Technical Data Sheet:
end check valve with the appropriate ◆ Optional Model F211 Retard Chamber used
For details, contact your local GEM Sales
“Ready-Riser” trim provides a riser check in installations subject to variable pressure
Office
valve with a hand hole cover if required (as generally associated with public water
Listings and Approvals: supplies) in order to help prevent false
Listings and Approvals: ULI, ULC, and FM
Components: UL and ULC alarms
Technical Data Sheet:
TD104A and TD104B Listings and Approvals:
ULI, ULC, FM, SSL, LPC, and VdS–F200
with DIN drilled flanges and special trim
Technical Data Sheet:
TD100 21⁄2" (65 mm) and
TD102 4", 6", and 8" (100mm, 150mm, and 200mm)
Model F20 Model F200 Model F2001
Groove Flange Flange
x x x
Size Groove Flange Groove
21⁄2"(65 mm) ◆ - ◆
4" (100 mm) ◆ ◆ ◆
6" (150 mm) ◆ ◆ ◆
8" (200 mm) - ◆ ◆
◆ = available

40
Back

GEM W ET PIPE S PRINKLER S YSTEMS

Model F540
Residential
Domestic Shutoff Valve
1" & 2"

Alarm Valve Trim


◆ Trim for 4", 6", and 8" ◆ During the design of a residential sprinkler system, domestic water use should be taken into
(100, 150, and 200 mm) alarm valves is consideration unless the domestic supply can be stopped when a sprinkler operates
semi-preassembled in modules at our ◆ When a sprinkler operates, water supply is automatically diverted from the domestic system
factory to help reduce the number of to the sprinkler system
connections that need to be made by the ◆ Eliminates the need for pumps, pressurized storage tanks, or electrically operated domestic
installing personnel shutoff valves
◆ Packaging provides a convenient method ◆ The valve automatically resets after the fire protection system is returned to normal service
for transporting materials either at the job
Listings and Approvals: ULI
site or to other locations
Technical Data Sheet: TD195

Typical Wet Pipe Sprinkler System

Water Motor
Alarm (Page 48)
Automatic
Sprinklers
(pages 10 to 27)
Check Valve
(Page 50) Inspector’s
Alarm Valve (Page 48) Test
Fire Dept. Connection
O. S. & Y. Gate Valve
Connection
To Control Water Supply To System
(Page 53)

Main Drain
Connection

Water Pressure
Water
Supply

41
Back

GEM DRY P IPE S PRINKLER S YSTEMS


Dry pipe sprinkler systems are installed in hazards where the piping and sprinklers can be subjected to freezing temperatures. Valving for the
system, however, must be installed in areas that are not subject to freezing, as this portion of the system does contain water. In most dry pipe
systems, pipe lines to the sprinklers are pressurized with air, but nitrogen is used at times. When pressure in the system is lost through the
actuation of a sprinkler head, the dry pipe valve trips and releases water into the system and activates alarms. The system may be equipped with
automatic or manual air supply controls and air supervisory devices with appropriate trouble alarms. Accessory items, such as dry pipe valve
accelerators which increase the speed of system operation, and pressure switches which are used to activate electric alarms, may be used to
enhance the system. Typical applications for dry pipe sprinkler systems include unheated warehouses, parking garages, store windows, attic
spaces, loading docks, and other areas exposed to freezing temperatures.

Model F311
Posi-Quick®
Model F3061 Dry Pipe Valve
Dry Pipe Valve Accelerator

◆ 2" (50 mm) and 3" (80 mm) sizes available ◆ Designed for use with Model F302 and F3021 dry pipe valves
◆ Flange x Groove body style ◆ Hastens operation of the dry pipe valve upon loss of air pressure
◆ Differential dry valves ◆ Automatically adjusts to small or slow changes in system pressure
◆ Valve operates when the system air pressure is reduced to approxi- but trips when there is a rapid and steady drop in pressure
mately one-sixth of the system water pressure ◆ Upon tripping, it transmits system air pressure to the intermediate
◆ Used to supply sprinkler installations in which sprinklers are chamber of the dry pipe valve which neutralizes the differential
subjected to freezing conditions (40˚F/4˚C or less) pressure holding the valve closed and opens the waterway clapper
Listings and Approvals: ULI, ULC, and FM ◆ Rated for use at a maximum water supply pressure of 175 psi
Technical Data Sheet: (12.1 bar) and a maximum system air (or nitrogen) pressure of 60
psi (4.1 bar)
TD106 which provides specifications and describes the trim for this
valve which is rated for use at a maximum service pressure of 175 ◆ Designed to trip when system air pressure drops at a rate exceeding
psi (12.1 bar) approximately 1 psi/minute (0.07 bar/min)
Listings and Approvals:
ULI, ULC, FM, LPC, SSL, and VdS.
Technical Data Sheet: TD109

Typical Dry Pipe Sprinkler System

Water Motor
Alarm (Page 48)
Automatic
Sprinklers
(pages 10 to 27)
Check Valve
(Page 50) Inspector’s
Dry Pipe Valve (Page 42 - 43) Test
Fire Dept. Connection
Connection O. S. & Y. Gate Valve
(Page 53) To Control Water Supply To System

Main Drain Check Valve (Page 50)


Connection

Heated Dry Pipe Valve Enclosure Water Pressure


Air Pressure
Water
Supply

42
Back

GEM DRY P IPE S PRINKLER S YSTEMS

Models F302 and F3021 Model F324 Model F326


Dry Pipe Valves Air Maintenance Devices Air Maintenance Devices
(shown with F311)
◆ Differential dry pipe valves ◆ Field adjustable ◆ Field adjustable
◆ Used in larger dry pipe sprinkler systems ◆ Used in systems where there is a plant ◆ Used in conjunction with a small, non-
◆ Both are available in 4" (100 mm) and 6" compressed air or nitrogen source tank-mounted air compressor
(150 mm) sizes ◆ Used in systems which the air supply is ◆ Monitors sprinkler system or dry pilot line
◆ Identical in design, except that model F302 supplied at a higher pressure than the system air system pressure and automati-
is furnished with grooved outlet connec- desired system air pressure for a cally cycles the compressor on-off to
tions sprinkler system or dry pilot line system maintain system pressure with preset
◆ Both have flanged inlet connections Listings and Approvals: ULI, ULC, and FM limits
◆ Rated for use at a maximum service Technical Data Sheet: TD111 Listings and Approvals: ULI, ULC, and FM
pressure of 175 psi Technical Data Sheet: TD112
(12.1 bar)
◆ Used to supply sprinkler installations in
which sprinklers are subjected to freezing
conditions (40˚F/4˚C or less)
Listings and Approvals:
ULI, ULC, FM, LPC, and SSL
VdS–F302 with DIN drilled flanges and
special trim
Technical Data Sheet: TD107

Dry Pipe Model F328


Valve Trim Nitrogen
Maintenance
Devices

◆ Trim for 4" and 6" (100 and 150 mm) dry pipe valves is semi- ◆ Field adjustable
preassembled in Modules at our factory to help reduce the number ◆ Used in conjunction with a cylinder of high pressure nitrogen to
of connections that need to be made by the installing personnel control the nitrogen pressure in a sprinkler system or a dry pilot
◆ Packaging provides a convenient method for transporting materials line system
either at the job site or to other locations Listings and Approvals: ULI, ULC, and FM
Technical Data Sheet: TD113

43
Back

GEM D ELUGE A ND P REACTION S YSTEMS


Deluge Valve and Deluge Systems Single Interlock
(Electric Detection Shown) Preaction Systems
The “deluge valve” is the automatic water The system is connected to a water supply Single interlock preaction systems are
control valve which is used to control through the deluge valve. This valve is used to protect areas where there is
water flow into deluge, preaction, and opened by the operation of a fire detection danger of serious water damage which
special types of fire protection systems in system installed in the same areas as the might result from damaged automatic
response to a fire. open sprinklers or nozzles. Deluge sprinklers or piping. Typically, such areas
systems may be activated by wet pilot or include computer rooms, storage areas for
Deluge fire protection systems are dry pilot sprinklers or electric detectors. valuable artifacts, libraries and archives.
normally used in special hazard installa- When the deluge valve opens, water flows Also, preaction systems are effectively
tions where an area application of water is into the piping system and discharges used to protect properties where a
required for protection. Typical applica- from all sprinklers and nozzles. Deluge prealarm of a possible fire condition may
tions may include manufacturing and systems are normally used for high allow time for fire extinguishment by
storage areas, aircraft hangars, and other hazards requiring an immediate application alternate suppression means, prior to the
high-hazard installations where water is of water over an entire hazard. Note: refer need for a sprinkler discharge. In the event
the most effective extinguishing agent. to numbered pages listed in this catalog the fire cannot otherwise be extinguished,
Deluge systems employ open sprinklers or for additional information on individual the preaction sprinkler system will then
spray nozzles attached to a piping system. devices. perform as the primary fire protection
system.

Single interlock preaction systems employ


automatic sprinklers attached to a piping
system containing 1.5 psi (0.1 bar) or 10
Spray Nozzles (pages 36 or 37) or Open Sprinklers psi (0.7 bar) supervisory pressure, with a
supplemental electric fire detection system
installed in the same area as the sprinklers.
Preaction systems with 10 psi (0.7 bar)
Electric Detectors

Double Interlock
Preaction System

Double interlock preaction systems are


Fire Alarm Model F630 designed for applications, such as
Bell Water Motor refrigerated areas, requiring the maximum
Alarm (page 48) degree of protection against an inadvertent
operation, which could result in unneces-
sary flooding of the sprinkler system
piping.
Solenoid Valve
normally closed
Double interlock preaction systems are
designed for applications, such as
refrigerated areas, requiring the maximum
degree of protection against an inadvertent
Waterflow operation, which could result in the
Electric Pressure Alarm unnecessary flooding of the sprinkler
Deluge Valve Manual Control Switch system piping. The double interlock
Releasing Stations system consists of a deluge valve and
Panel (page 48) swing check valve with releasing trim
Deluge Valve featuring both a solenoid valve and a dry
w/Deluge Trim pilot actuator in a series configuration. The
swing check valve isolates the body of the
O.S. & Y. Gate Valve deluge valve from the system air or
nitrogen pressure, which holds the dry
pilot actuator closed. The solenoid valve
remains closed until it is electrically
energized by a deluge releasing panel that
Water Pressure Atmospheric Pressure responds to the operation of a fire
detection device.

44
Back

GEM DELUGE A ND PREACTION S YSTEMS


(Electric Shown) Automatic Sprinklers (pages 10 to 27)

supervisory pressure may also be Model F520/F5201


activated by either wet pilot or dry pilot Check Valve (page 50)
sprinklers instead of electric detectors. Electric Detectors
Air/Nitrogen
Actuation of the fire detection system as Maintenance
from a fire opens the deluge valve which Device (page 43)
permits water to flow into the sprinkler Fire Alarm
piping system and to be discharged only Bell Model F630
from those sprinklers which have been Water Motor
operated by heat over the fire. Loss of Alarm (page 48)
Low Air Pressure
supervisory pressure from the system Alarm Switch
piping as a result of damaged sprinklers or
broken piping will activate a trouble alarm
to indicate impairment of the system. The Solenoid Valve
deluge valve will not open due to loss of normally closed
supervisory pressure. Single interlock
preaction systems are normally used to
protect properties where there is danger of
serious water damage as a result of Electric
damaged automatic sprinklers or broken Releasing Electric Manual Control
piping. Note: refer to numbered pages Panel (page 48) Waterflow
Station(s) Pressure Alarm
listed in this catalog for additional
Switch
information on individual devices. Deluge Valve
w/Single Interlock Trim
Technical Data Sheets: O.S. & Y. Gate Valve
TD1120 and TD1125.
Water Pressure Atmospheric Pressure Air Pressure

(Pneumatic/Electric Shown)
System Shut-Off Valve
Automatic Sprinklers (pages 10 to 27) Model F520/F5201
In order to actuate the double interlock Check Valve (page 50)
preaction system, two independent events,
caused by a fire condition, must occur. The Air/Nitrogen
Electric Detectors Maintenance
sprinkler system piping must lose air or Device (page 43)
nitrogen pressure due to the operation of
one or more sprinklers, and the deluge Fire Alarm
releasing panel must energize and open Bell
Model F630
the solenoid valve upon the operation of a Water Motor
Low Air Pressure
fire detection device. Alarm Switch Alarm (page 48)

The double interlock system will operate


only when both the dry pilot actuator and Dry Pilot Actuator
normally closed
the solenoid valve are open at the same
time. Opening of just the dry pilot actuator
(for example: a forklift truck accidentally Solenoid Valve
dislodges a sprinkler) or of just the normally closed
solenoid valve (for example: accidental
operation of an electric manual pull
Electric
station) will only cause an alarm, and will Electric Manual Control Waterflow
Releasing
not trip the system or flood the sprinkler Station(s) Pressure Alarm
Panel
system piping. Note: Refer to numbered (page 48) Switch
Deluge Valve
pages listed in this catalog for additional w/Double Interlock Trim
information on individual devices.
O.S. & Y. Gate Valve
Technical Data Sheets:
TD1146, TD1148, TD1151, and TD1153 Water Pressure Atmospheric Pressure Air Pressure Double Interlock

45
Back

GEM D ELUGE A ND P REACTION S YSTEMS

Model F470 Models F445 and F446 Model B


Multimatic® External Resetting Automatic Resetting Flooding Deluge Valve
Deluge Valve Deluge Valve

◆ Used as a system control valve in deluge, ◆ 21⁄2" (65 mm) F445 and F446 are right ◆ 2" NPT (50 mm) deluge valve
and single and double interlock preaction angle type deluge valves ◆ Used as the system control valve in
systems ◆ Available with either a grooved or threaded deluge, and single and double interlock
◆ Available in 4" (100 mm) and 6" (150 mm) inlet and outlet preaction systems
sizes ◆ For use as a control valve in deluge, or ◆ Actuates fire alarms when the system
◆ Can be reset externally without having to single or double interlock preaction operates
remove the hand-hole cover and unlatch systems ◆ Valves can be equipped with various trim
the waterway clapper ◆ F445 and F446 can be reset externally arrangements for actuation by manual,
◆ Available with three actuation trim without having to open a hand-hole cover pneumatic, electric, and hydraulic devices
arrangements: wet pilot, dry pilot, and to manually unlatch and set the center such as break-glass control station,
electric valve electric detectors, and dry pilot or wet pilot
◆ Single and double interlock preaction trims ◆ Model F445 is rated for a maximum 175 sprinklers
available psi (12.1 bar) service pressure ◆ The valve has a trip ratio of approximately
◆ Model F470H available without external ◆ Model F446 is rated for service pressures two and one half to one
reset for horizontal installations to 250 psi (17.2 bar) ◆ Rated for use at 175 psi (12.1 bar)
◆ Rated for 175 psi (12.1 bar) maximum ◆ Trim arrangements for the F445 provide maximum service pressure
service pressure wet pilot, dry pilot, and electric actuation Listings and Approvals:
Listings and Approvals: ◆ Trim for the F446 deluge valve provides ULI, ULC, FM, LPC, and SSL
ULI, ULC, FM, LPC, and SSL electric actuation Technical Data Sheet:
Technical Data Sheet: TD116 ◆ Valves may be installed with the outlet TD117A, TD117B, TD117C, TD117F, and
facing either left or right TD117V
Listings and Approvals:
F445: ULI, ULC, FM, LPC, and SSL. F446:
ULI, ULC, FM, and VdS
Technical Data Sheet:
TD114 for the F445 or TD114M for the
F446

46
Back

GEM DELUGE A ND PREACTION S YSTEMS

Model F430 Red-E Cabinet®


Thermal Control Valves

◆ Small deluge control valve designed for ◆ Complete riser assembly enclosed within a assembly for easy connections to the
limited size systems freestanding cabinet supply and system piping
◆ May be used as an auxiliary valve to ◆ Package is preassembled with all trim ◆ Available in deluge, single, and double
control the flow of water to specific areas installed and electric switches prewired, interlocked preaction system configura-
◆ Self contained, fixed temperature actuation making the connections for power, local, tions
device consisting of a fusible type solder remote alarms, and other external ◆ The electrical control panel for the systems
assembly, which is mounted on the top of electrical functions the only connections is normally a Potter 4410 releasing panel,
the valve needed to complete the installation but other controls are available upon
◆ Arms on top of the valve are color coded: ◆ Cabinet is constructed from 14 gauge steel request
plain for 165˚F/74˚C, and white for 212˚F/ ◆ Door is hinged for easy access ◆ Can be piped from either side for supply
100˚C temperature ratings ◆ Windows are provided for viewing system and drain functions
◆ Available in 1" (25 mm) and 11⁄2" (40 mm) gauges and other functions ◆ Discharge is vertical
sizes ◆ Grooved connections are provided on the Listings and Approvals:
◆ Rated for 175 psi (12.1 bar) service supply and discharge sides of the valve All components are UL, ULC, and FM
Listings and Approvals:
ULI, ULC, FM, LPC, and SSL
Technical Data Sheet: TD150

Valve Trim

◆ Valve trim for electric, wet pilot, or dry


pilot actuation of F445 and F470 deluge
valves are semi preassembled in our
factory to help reduce the number of
connections that need to be made by the
installing personnel
◆ Packaging provides a convenient method
for transporting materials either at the job
site or other locations

47
Back

GEM A LARM A ND S UPERVISORY D EVICES


Alarm and supervisory devices allow sprinkler and other fire protection systems to be interfaced with hydraulic or electronic alarm systems so that
upon activation of the system, an electrical or mechanical signal activates an audible or visible alarm or computerized notification device.

Models PS10-1A Model F630


and PS10-2A Water Motor
Pressure Alarm Alarm
Switches
◆ Designed to initiate electric alarms to indicate the operation of an ◆ Hydraulically operated outdoor alarm designed for use with
automatic sprinkler or deluge system appropriate fire protection system valves (alarm, dry, deluge)
◆ Supervisory low pressure alarm switch for preaction systems ◆ Supplied by dedicated outlet in valve trim line or retard chamber
having nominal supervisory pressure of 10 psi (0.7 bar) ◆ Uses energy-efficient lightweight impeller design capable of
◆ Initiates electric supervisory alarm to indicate leaks in sprinkler producing very high sound level
system piping upon decreasing air pressure ◆ Other features: corrosion-resistant aluminum alloy gong, gong-
◆ Model PS10A can be used to provide electrical function necessary mount, water motor housing and Delrin* bearings - which do not
to start auxiliary fire protection equipment or shut down manufac- require lubrication - for long life
turing processes ◆ May be mounted on any type of wall
◆ Model PS10-1A has one single-pole double-throw snap action switch ◆ Can accommodate range of wall thicknesses from 2" to 18"
◆ Model PS10-2A has two SPDT switches (50 to 450 mm)
◆ Components are enclosed in a NEMA Type 4 enclosure ◆ Furnished with approved 3⁄4" (20 mm) Y-strainer for use in alarm line
Listings and Approvals: ULI, FM, and LPC Listings and Approvals: ULI, ULC, FM, LPC, SSL, and VdS
Technical Data Sheet: TD213 Technical Data Sheet: TD250

PFC Series 100RC Model VSR-F


and 4410 Waterflow
Fire Control Panels Detectors

◆ Fire control panels provide the interface between detection system, ◆ Designed for use in wet pipe automatic sprinkler systems
deluge or single or double interlocked preaction valve, and signaling ◆ Available for 2" through 8" (50 through 200 mm) pipe sizes
circuit and devices in electrically actuated fire protection systems ◆ Vane-type sensor moves and actuates two SPDT switches when
◆ Separate supervisory zone provided for electronic supervision of water flows at sustained rate of 10 GPM (37.9 LPM)
valve position, low pressure, and other critical fire protection ◆ Waterflow detectors are used to actuate electrical alarms and/or
functions operate electrical equipment in sprinkler systems where mechanical
◆ Series 100RC is single-zone fire control panel alarms are not installed
◆ Series 4410 can be used in single zone, cross zone, sequential or ◆ Also used where sectional waterflow signals are required
cross/sequential electric deduction systems
Listings and Approvals: ULI, ULC and FM
◆ Series 4410 has programming capability
Technical Data Sheet: TD200B
Listings and Approvals: ULI and FM
Technical Data Sheets: TD270 (100RC)

48
Back

GEM ALARM A ND S UPERVISORY D EVICES

Model F114 Model F116


Model G16AC812 Pressure Reducing Type High-Pressure, Reducing Type
Automatic Supervisory Supervisory Nitrogen
Supervisory Air Supply Air Maintenance Device Maintenance Device
1.5 psi (0.10 bar) 1.5 psi (0.10 bar)
◆ Supplies and maintains air in single ◆ Automatic supervisory air maintenance ◆ An automatic nitrogen maintenance device
interlock preaction fire protection systems device of the pressure reducing type of the high pressure reducing type
having a nominal supervisory air pressure ◆ Used in conjunction with a plant air supply ◆ Used in conjunction with a cylinder of high
of 10 psi (0.7 bar) to control the supervisory pressure in pressure nitrogen to control the supervi-
◆ Can be mounted on the floor, on a wall, or preaction fire protection systems at a sory pressure in preaction fire protection
using optional brackets to the system riser nominal pressure of 1.5 psi (0.10 bar) systems of a nominal pressure of 1.5 psi
Listings and Approvals: ULI Listings and Approvals: ULI and FM (0.10 bar)
Technical Data Sheet: TD126 Technical Data Sheet: TD127 Listings and Approvals: ULI and FM
Technical Data Sheet: TD129

Type J33AX-5835 1.5 psi (0.10 bar)


Pressure Alarm Switch Low Pressure
Alarm Switches
◆ Used to supervise the dry pilot actuation ◆ Intended for use in detecting a low
trim of deluge valves pressure condition in 1.5 psi (0.10 bar)
◆ Low pressure alarm switch is set for a supervised (air or nitrogen) preaction
normal pressure exposure of 30 psi piping system
(2.1 bar) ◆ Initiates a signal when the supervisory
◆ If the pressure drops to 24 psi (1.7 bar), pressure drops below its minimum normal
the low pressure alarm contacts close value for any reason
◆ If the pressure drops to 15 psi (1.0 bar), ◆ Factory set to alarm at approximately
contacts on the fire alarm switch close, 0.75 psi (0.05 bar) on decreasing pressure
allowing a signal to be sent to fire alarm ◆ Available with watertight or explosion
devices proof rated enclosures
◆ Field adjustable to other pressure settings Listings and Approvals: ULI and FM
Listings and Approvals: ULI and FM Technical Data Sheet: TD225
Technical Data Sheet: TD210

*E.I. DuPont trademark. 49


Back

GEM G ENERAL PURPOSE V ALVES


The following general purpose valves are for use in fire protection service applications where it is necessary to prevent reverse flow, or where
system shut-off or sectional control is desired for closing a fire protection system after operation or to facilitate testing. Also, there are valves for
reducing high pressures for both sprinkler piping and hose stations.

Model F512 4" (100 mm) Model F514 Models F52, F520, and F5201
Wafer Check Valves Swing Check Valve Check Valves
◆ O-ring sealed clapper, torsion spring ◆ Grooved end connection swing check ◆ Rubber faced swing check valves
loaded, butterfly type check valves valve that has a rubber faced clapper ◆ May be installed vertically or horizontally
◆ Designed for use in fire protection systems design ◆ Can be used for gravity and pressure tank
and related piping ◆ Provides a nominal pressure drop of only connections, connections from public
◆ Permits rapid closure and minimizes water 1.4 psi (0.10 bar) at 600 GPM (2270 LPM) water supplies to automatic sprinkler
hammer, which can be associated with ◆ Leak tight sealing of back pressure systems, fire pump discharge and by-pass
reverse flow greater than 1.0 psi (0.07 bar) connections and in preaction systems
◆ Available in 4" (100 mm), 6" (150 mm), ◆ Rated for use in up to 250 psi (17.2 bar) having a nominal supervisory pressure of
and 8" (200 mm) sizes service 1.5 psi (0.10 bar) or greater
◆ Rated for use at a maximum service ◆ Furnished with 1⁄2" NPT drain connection Listings and Approvals: ULI, ULC, and FM
pressure of 250 psi (17.2 bar) tap, which is ideal for use with fire Technical Data Sheet: TD318 and TD320
◆ Leak tight at back pressures at greater department connections
than 1.0 psi (0.07 bar) Listings and Approvals: ULI, ULC, and FM Model F52 Model F520 Model F5201
Groove Flange Flange
◆ May be installed in either horizontal or Technical Data Sheet: TD315 x x x
vertical lines Size Groove Flange Groove
Listings and Approvals: ULI, ULC, and FM
21⁄2"(65 mm) ◆ - -
Technical Data Sheet: TD300
4" (100 mm) ◆ ◆ ◆
6" (150 mm) ◆ ◆ ◆
8" (200 mm) - ◆ ◆
◆ = available

50
Back

GEM G ENERAL P URPOSE V ALVES

Series 7800FP Models F570 and F571 Models F575 and F576
Grooved End Swing 21⁄2" (65 mm) Sectional Control 21⁄2" (65 mm) Hose Station Type
Check Valves Pressure Control Valves Pressure Reducing Valves
◆ Available in sizes 2" through 12" (50mm ◆ Straight pattern, balanced piston, valves ◆ Straight pattern, balanced piston, hose
through 300 mm) ◆ Designed to reduce inlet pressure of up to station valves
◆ Can be installed either vertically or 400 psi (27.6 bar) to a maximum outlet ◆ Designed for use in Classes I and III
horizontally pressure of 165 psi (11.4 bar) in sections standpipe system service to reduce
◆ Rated for use at a maximum pressure of or zones of wet pipe system standpipe (inlet) and pressure of up to
250 psi (17.2 bar) ◆ Model F570 has cut groove inlet and outlet 400 psi (27.6 bar) down to one of three
◆ Cut groove inlet and outlet connections connections factory set hose (outlet) pressure under
◆ Suitable for use with grooved pipe ◆ Model F571 has a 2 1⁄2" NPT threaded inlet both flow and static conditions
couplings that are listed or approved for and a cut groove outlet ◆ F575 has a cut groove inlet
fire protection service ◆ Factory set to provide 165 psi (11.4 bar) ◆ F576 has a threaded NPT inlet
Listings and Approvals: outlet pressure; therefore, there is no need ◆ The valve outlet is provided “standard
ULI, ULC, FM, and VdS to “special order” valves based on inlet order” with a 21⁄2" male hose outlet
Technical Data Sheet: TD313 pressure due to the level or floor when connection per NFPA 1963 (2.5-7.5 NH)
used in high-rise buildings ◆ Valves automatically adjust the outlet
Listings and Approvals: ULI and ULC pressure, as the inlet pressure varies from
Technical Data Sheet: TD360 the minimum setting up to 400 psi
(27.6 bar)
◆ 3 available outlet settings are
155 psi, 140 psi, and 120 psi
(10.7 bar, 9.7 bar, and 8.3 bar)
Listings and Approvals: ULI and ULC
Technical Data Sheet: TD370

51
Back

GEM G ENERAL PURPOSE V ALVES AND S PECIALTY ITEMS

Series 7700FP Series 7700HFP Models BB-SCS01 and BB-SC100


Butterfly Valves Butterfly Valves Butterfly Valves
175 psi 300 psi 175 psi
◆ Available in sizes 2" through 10" ◆ Available in sizes 3" through 8" (50 mm ◆ Bronze body butterfly valves are designed
(50 mm through 200 mm) through 200 mm) specifically for fire protection applications
◆ Gear operator standard ◆ Gear operator standard ◆ Feature slow closure which substantially
◆ Rated for maximum service pressure of ◆ Rated for maximum service pressure of minimizes water hammer
175 psi (12.1 bar) 300 psi (20.7 bar) ◆ May be used as sectional or small system
◆ Used when visual indication of whether ◆ Used when visual indication of whether control valves where a distinct visual
valve is open or closed is required valve is open or closed is required indication of the valve status is required
◆ Cut groove inlet and outlet connections ◆ Cut groove inlet and outlet connections ◆ Model BB-SCS01 has built in tamper
◆ Spherical bore provides constant disc seal ◆ Spherical bore provides constant disc seal resistant SPDT switch for use where
loading, which maintains leak tight seal loading, which maintains leak tight seal proprietary or central station supervision
regardless of position regardless of position of open position of valve is required
◆ May be provided with or without internal ◆ May be provided with or without internal ◆ Rated for use at a maximum service
supervisory switches supervisory switches pressure of 175 psi (12.1 bar)
Listings and Approvals: ULI, ULC, and FM Listings and Approvals: ULI, ULC and FM ◆ Both models available in 2" and 21⁄2" NPT
Technical Data Sheet: TD355 Technical Data Sheet: TD356 Listings and Approvals: ULI, ULC, and FM
Technical Data Sheet: TD350

Model A and B Model C


Pipe Line Strainer
Strainers
(Model B shown)

◆ Available in 3" thru 10" (80mm thru 250 mm) sizes for the model A, ◆ Available in several sizes
3" thru 8" (80mm thru 200 mm) for the model B 6" x 6" (150 mm x 150 mm)
◆ Rated for use in services up to 175 psi (12.1 bar) 8" x 8" (200 mm x 200 mm)
◆ Bodies of the model A are welded steel and 150 lb. flanges. Cast 8" with 2 - 6" outlets (200 mm with 2 - 200 mm outlets)
iron reducing inlet flanges and blind flanges complete the assembly.
10" with 2 - 8" outlets (250 mm with 2 - 200 mm outlets)
Entire assembly is hot dipped galvanized.
◆ Rated for use in services up to 250 psi (17.2 bar)
◆ Bodies of 3", 4" and 6" B-1 strainers are cast iron flanged tees. 8"
B-1 strainers are pieces of welded Schedule 30 steel pipe and Class ◆ Compact lightweight welded hot dipped assembly with flanged inlet,
150 steel flanges outlet and flushing connection.
Listings and Approvals: ULI, UL and FM ◆ Corrosion resistant Type 304 stainless steel screen especially
designed for low pressure loss
Technical Data Sheet: TD401 (Model A) and TD402 (Model B)
Listings and Approvals: ULI, C-UL and FM
Technical Data Sheet: TD402M

52
Back

GEM SPECIALTY I TEMS


Specialty items may be used in conjunction with other products in this catalog to help provide the functions necessary to meet the requirements of a
properly designed fire protection system.

Model F350 Model F713 Models F715, F716, and F717 Fire
Sectional Test and Drain Fire Department Connection Department Connections
◆ Integral sight-glass assembly ◆ Used as auxiliary water supply connection ◆ Similar in operation to model F713
◆ Simplified method of testing waterflow to automatic sprinkler systems or ◆ Models F715 (straight), F716 (45°) and
alarms and draining sections of fire standpipe fire protection systems F717 (90°) offer dual fire department
protection systems ◆ Allows fire departments to pump water hookups
Listings and Approvals: ULI and FM into a fire protection system from Listings and Approvals: ULI and FM
Technical Data Sheet: TD455 hydrants, ponds, and reservoirs Technical Data Sheet: TD411
Listings and Approvals: ULI
Technical Data Sheet: TD410

GEM Model F789


Flameaway® CPVC Automatic Drain
Pipe and Fittings (Ball Drip) Valve

◆ Intended for use in wet pipe residential fire protection systems ◆ Automatically drains water from fire protection equipment
◆ Available in 3⁄4"–2" (20-50 mm) sizes (under low pressure)
◆ Superior heat resistance ◆ Provides visual indication of leakage past a check valve
◆ Excellent water flow characteristics ◆ Automatically drains off condensate in fire protection systems
◆ Easy to install Listings and Approvals: ULI and FM
◆ Various adapters are available to connect Flameaway pipe to metal Technical Data Sheet: TD425
piping used in fire sprinkler systems, as well as cut-grooved
adapters and male and female pipe-thread adapters
◆ All male and female thread adapters have brass inserts for durability
Listings and Approvals: ULI, C-UL, and FM
Technical Data Sheet: TD900

53
Back

S PRINKLER PIPE
Allied Tube and Conduit manufactures pipe for the North American sprinkler industry. All pipe is manufactured to the standards of the American
Society of Testing Materials (ASTM) for pipe meeting codes A-135 and/or A-795. These are also recognized by the National Fire Protection
Association (NFPA) as being acceptable for steel pipe for fire sprinkler installations.
Allied is the largest producer of sprinkler pipe in North America. Allied also produces fence products, tubular steel for recreational products,
electrical conduit, and steel channel (strut) for industrial hanger use.

Allied® Schedule 10 Pipe Allied® Schedule 40 Pipe Allied Dyna-Thread® Pipe


◆ Quality product with exceptional physical ◆ Designed and manufactured for installation ◆ Manufactured in sizes 1" through 2"
characteristics and superior hydraulic in today’s advanced-technology sprinkler (25 mm through 50 mm) sizes to ASTM
design advantages systems A795/A 135 Type E Grade A, for maximum
◆ Ideally suited for use in any sprinkler ◆ Meets or exceeds all industry and ASTM working pressure of 300 psi (20.7 bar)
system installation A135 Specifications ◆ Available in standard lengths of 21', 24'
◆ Complies with ASTM A135 and allows for ◆ Produced in sizes 1" through 21⁄2" (25 mm and 25' (6.4, 7.3 and 7.6 meters)
easier handling to facilitate installation and through 65 mm) in standard lengths of ◆ Offers better flow characteristics than
significantly reduce labor costs 21', 24', and 25' (6.4m, 7.3m and 7.6m) Schedule 40 pipe, with comparable wall
◆ Produced in sizes 11⁄4" through 8" (32mm Technical Data Sheet: thickness
through 200mm) in standard lengths of See current Pipe Catalog and Data Sheets ◆ UL listed and FM approved as threadable
21', 24', and 25' (6.4m, 7.3m, and 7.6m) for more information lightwall product
Technical Data Sheet: Technical Data Sheet:
See current Pipe Catalog and Data Sheets See current Pipe Catalog and Data Sheets
for more information for more information

Allied Allied
Dyna-Flow® Pipe BLT®/XL Pipe

◆ Represents latest technical advancement in light wall sprinkler pipe ◆ Threadable light wall sprinkler pipe manufactured in 1" through 3"
◆ Ideally suited for use in most sprinkler system installations, and sizes (25 mm through 80 mm)
offers advantageous hydraulic design characteristics ◆ XL is exterior galvanized - BLT is black
◆ Dyna-Flow is lightweight but incredibly strong, and allows for ease ◆ Engineered to provide best in low-cost sprinkler protection
of handling to facilitate installation, at significantly reduced labor ◆ For use in accordance with NFPA 13, 13D, and 13R, as threaded or
costs unthreaded in wet, dry, preaction or deluge systems
◆ Complies with ASTM A795 and is available in sizes 1" through 4" ◆ Rated for pressures of up to 300 psi (20.7 bar) and complies with
(25 through 100 mm) in lengths of 21', 24' and 25' ASTM A135
(6.4, 7.3 and 7.6 m) ◆ Available in standard lengths of 21', 24' and 25'
◆ UL, ULI Listed and FM approved as engineered lightwall pipe (6.4m, 7.3m and 7.6m)
Technical Data Sheet: ◆ UL listed and FM approved as threadable lightwall sprinkler pipe
See current Pipe Catalog and Data Sheets for more information Technical Data Sheet:
See current Pipe Catalog and Data Sheets for more information

54
Back
Customized Submittal Sheets • Product Technical Data
Sheets • CAD Details • Sprinkler Selection Guide

GEM’s electronic Fire


Protection Products CD tops the
charts! Featuring more than
1,200 fire protection products,
it’s one CD you’ll never grow
tired of playing.

For more information, or to order your free copy of


GEM’s electronic Fire Protection Products CD,
contact GEM Sprinkler at 888-610-6101.

Be sure to visit our web site at: www.gemsprinkler.com


55
Back
UNITED STATES
GEM SPRINKLER COMPANY HEADQUARTERS
323 East 151st Street
Harvey, IL 60426
Phone: 877-436-8926
Fax: 877-866-9250
www.gemsprinkler.com

ASIA
SINGAPORE
65-847-0880, Fax 65-847-3919
MALAYSIA
Petaling Jaya: 60-3-572-2773, Fax 60-3-572-2755
HONG KONG
Kowloon: 852-2766-0860, Fax 852-2766-3070
TAIWAN
Taipei: 886-2-377-6226, Fax 886-2-377-5991

AUSTRALIA
NEW SOUTH WALES
Hoxton Park: 02-607-6133, Fax 02-608-4224
QUEENSLAND
Rocklea: 07-274-2575, Fax 07-274-2858
SOUTH AUSTRALIA
Athol Park: 08-268-4722, Fax 08-347-1892
MELBOURNE
Bundoora: 03-9467-7122, Fax 03-9467-7526
WESTERN AUSTRALIA
Welsapool: 09-353-4022, Fax 09-353-4015

EUROPE
NETHERLANDS
Kopersteden 1, NL-7547 TJ Enschede
P.O. Box 198, 7500 AD
Enschede, Holland
31-53-428-3434, Fax 31-53-428-3377
UNITED KINGDOM
Stockport: 44-61-429-9730, Fax 44-61-429-9735
FRANCE
Paris Nord II: 33-1-48178727, Fax 33-1-48178720
GERMANY
D-63110 Rodgau: 49-6106-84455, Fax 49-6106-18177
SPAIN
Coslada Madrid: 03-34-1-669-3906, Fax 03-34-1-669-2018 DISTRIBUTED BY
LATIN AMERICA
MIAMI, FLORIDA, USA
2610 N.W. 89th Court
Miami, FL 33172
305-448-0059, Fax 305-448-1632
ARGENTINA
Buenos Aires: 54-11-4246-4233, Fax 54-11-4246-4487
Buenos Aires: 54-11-4308-6444, Fax 54-11-4308-6445
Mendoza: 54-26-1498-0642, Fax 54-26-1498-1765
BRAZIL
Rio De Janeiro: 55-21-240-9695, Fax 55-21-240-6770
Sorocaba-São Paulo: 55-15-228-3555, 55-15-228-3391
São Paulo: 55-11-362-4011, 55-11-261-3823
CHILE
Santiago: 56-2-538-1800, Fax 56-2-538-0050
MEXICO
Guadalajara, Jalisco: 52-3-668-4000, Fax 52-3-668-4012
Mexico City: 52-5-207-5766, Fax 52-5-207-7566
VENEZUELA
Caracas, 1080-A: 58-2-991-7577, Fax 58-2-991-6409
Maracaibo: 58-61-91-0526, Fax 58-61-93-1894
PERU
Lima: 511-332-9564, Fax: 511-332-9568

NEW ZEALAND
AUCKLAND 09-827-2290, Fax 09-827-2288

#115 / Printed in USA / UL / 4.00 / 20M / ©2000

You might also like