0% found this document useful (0 votes)
31 views2 pages

Summary

This document provides a summary of lighting calculations for a master bedroom including the daylight factor, working plane illumination levels, glare valuation, estimated energy consumption, and lighting power density. It also lists the luminaires used in the bedroom with details on their glare rating, power consumption, luminous flux, and luminous efficacy. The results are checked against various target values and indices.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views2 pages

Summary

This document provides a summary of lighting calculations for a master bedroom including the daylight factor, working plane illumination levels, glare valuation, estimated energy consumption, and lighting power density. It also lists the luminaires used in the bedroom with details on their glare rating, power consumption, luminous flux, and luminous efficacy. The results are checked against various target values and indices.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

fisbang

Site 1 · Building 1 · Storey 1 · Master Bedroom (ARTIFICIAL)


Summary

Ground area 57.84 m² Clearance height 2.500 m – 3.000 m

Reflection factors Ceiling: 67.2 %, Mounting height 0.700 m – 3.000 m


Walls: 34.1 %,
Floor: 33.9 % Height Working plane 1.000 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

1
fisbang

Site 1 · Building 1 · Storey 1 · Master Bedroom (ARTIFICIAL)


Summary

Results

Symbol Calculated Target Check Index

Daylight D 0.736 % – DF1

Working plane Ēperpendicular 254 lx ≥ 250 lx WP1

Ē/E min 876 ≤ 3.00 WP1

Glare valuation(1) RUG, max 28 ≤ 22

Energy estimation(2) Consumption [293.08 - 369.99] kWh/a max. 2050 kWh/a

Room Lighting power density 3.32 W/m² –

1.31 W/m²/100 lx –

(1) Based on a rectangular space of 8.920 m x 6.484 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: 33 - LIGHTING FOR RESIDENCES (Residental Interiors; Bedrooms, Television Viewing)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

2 BRIGHT LED-LAMP PENNA 3 TABLE – 14.0 W 1521 lm 108.6 lm/W


SPECIAL
LIGHTING S.A.

1 LEDS C4 S.A. 10-3273-2 Queen 28 7.0 W 284 lm 40.5 lm/W


1-05

3 Philips PT320T 1 xLED39S/PW930 MB 17 36.0 W 3857 lm 107.1 lm/W

4 Philips RS150B LED12S/840 WB D78 PSR 20 12.3 W 1322 lm 107.5 lm/W