This document provides specifications for ESB Bus Node Units (ANB10S, ANB10D) that interface analog and digital I/O signals between a field and a Field Control Unit via an ESB bus. The node units have power supply modules and can connect up to 8 I/O modules. They support various power supply voltages and regulatory compliance standards. Installation is limited based on ambient temperature and I/O module configuration. Dimensions and model codes are provided.

Uploaded by

manzoor9603302
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views4 pages

GS33K50F20 50e

This document provides specifications for ESB Bus Node Units (ANB10S, ANB10D) that interface analog and digital I/O signals between a field and a Field Control Unit via an ESB bus. The node units have power supply modules and can connect up to 8 I/O modules. They support various power supply voltages and regulatory compliance standards. Installation is limited based on ambient temperature and I/O module configuration. Dimensions and model codes are provided.

Uploaded by

manzoor9603302
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

<<Contents>> <<Index>>

General Models ANB10S, ANB10D


Specifications ESB Bus Node Units (for FIO)

GS 33K50F20-50E

 GENERAL
The ESB Bus Node Unit has an interface function that
communicates the analog I/O signals and contact I/O
signals of a field with a Field Control Unit (FCU) via an
ESB bus, as well as a function that supplies power to
the I/O Modules.
This node units are connected to FCU via an ESB
bus.

 HARDWARE SPECIFICATIONS
For the installation specifications and environmental
conditions that are common to the systems, refer to
“FIO System Overview (for Vnet/IP) (GS 33K50F10-
50E).”

 No. of Node Units Connectable


Vnet/IP
F01.ai

Field
Total Number of ESB Bus Node Units (ANB10) and Optical
Control Database
ESB Bus Node Units (ANB11) Connected per FCU
Unit
Control Function for Field Control Station (LFS1700) Max. 3
AFV30 Control Function for Field Control Station (LFS1700)
Max. 9
AFV40 plus Node Expansion Package (LFS1750-V1)
(*1) Control Function for Field Control Station (LFS1700)
Max. 13
plus Node Expansion Package (LFS1750-V2)

*1: Up to 11 node units per 1 cabinet can be installed in AFV40.

Total Number of
ESB Bus Node
Field ESB Bus Node ER Bus Node
Units (ANB10)
Control Database Units (ANB10) Units (ANR10)
and ER Bus Node
Unit Connected per FCU Connected per FCU
Units (ANR10)
Connected per FCU
Control Function for Field Control Station (LFS1500) Max. 3 Max. 3 Max. 3
AFV10 Control Function for Field Control Station (LFS1500)
plus Application Capacity Expansion Package Max. 9 Max. 14 Max. 14
(LFS1550)

Vnet
Total Number of
ESB Bus Node
Field ESB Bus Node ER Bus Node
Units (ANB10)
Control Database Units (ANB10) Units (ANR10)
and ER Bus Node
Unit Connected per FCU Connected per FCU
Units (ANR10)
Connected per FCU
Control Function for Compact Field Control Station
AFF50 Max. 3 Max. 3 Max. 3
(LFS1350)
AFG30 Control Function for Enhanced Field Control Station
Max. 10 Max. 14 Max. 15
AFG40 (LFS1330) with Node expanded databases
Others Max. 10 (*1) Max. 9 (*1) Max. 10 (*1)

*1: In Case of AFG81 and AFG82, there are total number with SIO Nest (for CENTUM V or CENTUM-XL).
Total number of SIO: Max 5/FCU

Yokogawa Electric Corporation GS 33K50F20-50E


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright Aug. 2011 (YK)
Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 6th Edition June 12, 2013 (YK)
<<Contents>> <<Index>> 2
 ESB Bus Node Connection
When connecting an ESB Bus Node Unit to FCU, install ESB Bus Coupler Module (EC401 or EC402) to FCU (*1).
EC401 or EC402 must be installed in slot 7 and slot 8. To make single configuration, EC401 or EC402 must be
installed in slot 7, and Slot 8 must be empty.
EC402 can be installed in AFV30 or AFV40.
*1: AFV30, AFV40, AFV10, or AFF55.

 Power Supply
Specify with Suffix Codes
Voltage: 100-120 V AC, Frequency: 50/60 Hz
Voltage: 220-240 V AC, Frequency: 50/60 Hz
Voltage: 24 V DC

 Electric Power Consumption


100-120 V AC: 200 VA, 120 W
220-240 V AC: 230 VA, 120 W
24 V DC: 5.5 A

 Weight
10 kg (incl. 8 I/O Modules)

 Mounting
19-inch Rack Mounting
Rack mount (M5 x 4 screws)
Insulation bash (accessory)

 Regulatory Compliance
For the detailed information of following standards, see “System Overview” (GS 33K01A10-50E).
Safety Standards
[CSA] (for 100-120 V AC and 24 V DC power supply)
[CE Marking] (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)
EMC Conformity Standards
[CE Marking] (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)
[C-Tick Marking] (for 220-240 V AC and 24 V DC power supply)
[KC Marking] (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)
Standards for Hazardous Location Equipment
[CSA Non-Incendive] (for 100-120 V AC and 24 V DC power supply)
[FM Non-Incendive] (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)
[Type n] (for 24 V DC power supply)

 CONFIGURATION
 Module configuration
Power Supply Module (PW481 or PW482 or PW484): Two modules in case of a dual-redundant configuration.
Power supply to the I/O Modules, and supply power to the transmitters.
The power supply terminals use M4 screws.
ESB Bus Interface Slave Module (SB401): Two modules in case of a dual-redundant configuration.
I/O Modules (*1): Max. 8

*1: Non-standard components.

 LIMITATIONS OF INSTALLATION AND NOTICES FOR INSTALLATION


For installing I/O modules in node unit, the quantity and allocation are limited. Also, when installing a node unit to
the dedicated cabinet, there are limitations of installation under the ambient operating temperature conditions. When
modules with built-in barriers are installed in any node unit, an insulating partition (Part No. T9083NA) must be
installed.
For details, please refer to “FIO System Overview (for Vnet/IP)” (GS 33K50F10-50E) and “Installation Guidance” (TI
33K01J10-50E).

All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 33K50F20-50E Sep. 1, 2012-00
<<Contents>> <<Index>> 3
 EXTERNAL DIMENSIONS
 ANB10D, ANB10S ESB Bus Node Unit (Figure of ANB10D)
Unit: mm

482.6 205
8.75 465.1 150.6 18.4
21.3 440

146
221.5

Hole for mounting on a 19-inch rack


37.75 (4 holes for M5 screws)
F03E.ai

All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 33K50F20-50E Dec. 7, 2011-00
<<Contents>> <<Index>> 4
 MODELS AND SUFFIX CODES
Node Unit for Single ESB Bus
*1: If ANB10 is connected to the Optical ESB Bus
Description Node Unit (ANB11), “ISA Standard G3 option
Model ANB10S Node Unit for Single ESB Bus and temperature (-20 to 70 °C) option” may be
-3 Single power supply specified.
*2: Select the option code “/ATDOC” to follow the
-4 Dual-redundant power supply
ATEX Directive for use in potentially explosive
1 100 - 120 V AC power supply atmospheres.
2 220 - 240 V AC power supply *3: It must be sure to specify the Option Code
4 24 V DC power supply “/NDEL” to connect Node Unit with AFV10,
AFV30, AFV40 and AFF50.
Basic type with no explosion
5 Dummy Cover
protection
With ISA Standard G3 option, Description
Suffix 6 temperature (-20 ˚C to 70 ˚C) option,
Codes and no explosion protection (*1) ADCV01 Dummy Cover (for I/O Module)
With ISA Standard G3 option and no Model Dummy Cover (for Power Supply
7 ADCV02
explosion protection Module)
E Basic type with explosion protection
With ISA Standard G3 option, Insulating Partition
F temperature (-20 ˚C to 70 ˚C) option,
and explosion protection (*1) Description
With ISA Standard G3 option and Part No. T9083NA Insulating Partition
G
explosion protection
Note: When mounting an FIO module with built-in
Connector Unit for ESB Bus barrier to a node unit, place this part to the 8th
/CU1N
[part No.: S9562FA] slot.
Connector Unit with Terminator for
Option /CU1T
ESB Bus [part No.: S9564FA]
Codes
/ATDOC Explosion Protection Manual (*2)
 ACCESSORIES AND SPARE PARTS
Software License for Node Expansion
/NDEL Parts Parts
(*3) Description Quantity Remarks
Names Numbers
Insulating
Node Unit for Dual-Redundant ESB Bus S9049PM – 4 Accessory
bush
Description
Node Unit for Dual-Redundant ESB
Model ANB10D
Bus  ORDERING INFORMATION
-4 Dual-redundant power supply Specify the model and suffix codes.
For selecting the right products for explosion protection,
1 100 - 120 V AC power supply
please refer to TI 33Q01J30-01E without fail.
2 220 - 240 V AC power supply
4 24 V DC power supply
Basic type with no explosion  TRADEMARKS
5
protection • CENTUM and Vnet/IP are registered trademarks of
With ISA Standard G3 option, Yokogawa Electric Corporation.
Suffix 6 temperature (-20 ˚C to 70 ˚C) option, • Other product and company names appearing in this
Codes and no explosion protection (*1) document are trademarks or registered trademarks of
With ISA Standard G3 option and no their respective holders.
7
explosion protection
E Basic type with explosion protection
With ISA Standard G3 option,
F temperature (-20 ˚C to 70 ˚C) option,
and explosion protection (*1)
With ISA Standard G3 option and
G
explosion protection
Connector Unit for ESB Bus
/CU2N
[part No.: S9562FA (2 pieces)]
Connector Unit with Terminator for
Option /CU2T ESB Bus
Codes [part No.: S9564FA (2 pieces)]
/ATDOC Explosion Protection Manual (*2)
Software License for Node Expansion
/NDEL
(*3)

All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 33K50F20-50E June 12, 2013-00