<<Contents>> <<Index>>
General                                             Models ANB10S, ANB10D
Specifications                                       ESB Bus Node Units (for FIO)
GS 33K50F20-50E
 GENERAL
The ESB Bus Node Unit has an interface function that
communicates the analog I/O signals and contact I/O
signals of a field with a Field Control Unit (FCU) via an
ESB bus, as well as a function that supplies power to
the I/O Modules.
This node units are connected to FCU via an ESB
bus.
 HARDWARE SPECIFICATIONS
For the installation specifications and environmental
conditions that are common to the systems, refer to
“FIO System Overview (for Vnet/IP) (GS 33K50F10-
50E).”
 No. of Node Units Connectable
Vnet/IP
                                                                                                                                      F01.ai
  Field
                                                                      Total Number of ESB Bus Node Units (ANB10) and Optical
 Control                          Database
                                                                          ESB Bus Node Units (ANB11) Connected per FCU
  Unit
       Control Function for Field Control Station (LFS1700)                                        Max. 3
AFV30 Control Function for Field Control Station (LFS1700)
                                                                                                   Max. 9
AFV40 plus Node Expansion Package (LFS1750-V1)
  (*1) Control Function for Field Control Station (LFS1700)
                                                                                                  Max. 13
       plus Node Expansion Package (LFS1750-V2)
   *1:     Up to 11 node units per 1 cabinet can be installed in AFV40.
                                                                                                                       Total Number of
                                                                                                                        ESB Bus Node
  Field                                                               ESB Bus Node           ER Bus Node
                                                                                                                       Units (ANB10)
 Control                          Database                           Units (ANB10)         Units (ANR10)
                                                                                                                      and ER Bus Node
  Unit                                                              Connected per FCU      Connected per FCU
                                                                                                                       Units (ANR10)
                                                                                                                     Connected per FCU
       Control Function for Field Control Station (LFS1500)                  Max. 3                Max. 3                   Max. 3
AFV10 Control Function for Field Control Station (LFS1500)
       plus Application Capacity Expansion Package                           Max. 9               Max. 14                   Max. 14
       (LFS1550)
Vnet
                                                                                                                       Total Number of
                                                                                                                        ESB Bus Node
  Field                                                               ESB Bus Node           ER Bus Node
                                                                                                                       Units (ANB10)
 Control                          Database                           Units (ANB10)         Units (ANR10)
                                                                                                                      and ER Bus Node
  Unit                                                              Connected per FCU      Connected per FCU
                                                                                                                       Units (ANR10)
                                                                                                                     Connected per FCU
       Control Function for Compact Field Control Station
 AFF50                                                                      Max. 3                Max. 3                    Max. 3
       (LFS1350)
AFG30 Control Function for Enhanced Field Control Station
                                                                             Max. 10              Max. 14                   Max. 15
AFG40 (LFS1330) with Node expanded databases
                         Others                                            Max. 10 (*1)          Max. 9 (*1)              Max. 10 (*1)
   *1:     In Case of AFG81 and AFG82, there are total number with SIO Nest (for CENTUM V or CENTUM-XL).
           Total number of SIO: Max 5/FCU
                                                    Yokogawa Electric Corporation                                           GS 33K50F20-50E
                                                    2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan          ©Copyright Aug. 2011 (YK)
                                                    Tel.: 81-422-52-5634 Fax.: 81-422-52-9802                  6th Edition June 12, 2013 (YK)
<<Contents>> <<Index>>                                                                                                   2
 ESB Bus Node Connection
When connecting an ESB Bus Node Unit to FCU, install ESB Bus Coupler Module (EC401 or EC402) to FCU (*1).
EC401 or EC402 must be installed in slot 7 and slot 8. To make single configuration, EC401 or EC402 must be
installed in slot 7, and Slot 8 must be empty.
EC402 can be installed in AFV30 or AFV40.
    *1: AFV30, AFV40, AFV10, or AFF55.
 Power Supply
  Specify with Suffix Codes
  Voltage: 100-120 V AC, Frequency: 50/60 Hz
  Voltage: 220-240 V AC, Frequency: 50/60 Hz
  Voltage: 24 V DC
 Electric Power Consumption
  100-120 V AC: 200 VA, 120 W
  220-240 V AC: 230 VA, 120 W
  24 V DC: 5.5 A
 Weight
  10 kg (incl. 8 I/O Modules)
 Mounting
  19-inch Rack Mounting
            Rack mount (M5 x 4 screws)
            Insulation bash (accessory)
 Regulatory Compliance
For the detailed information of following standards, see “System Overview” (GS 33K01A10-50E).
Safety Standards
  [CSA]                (for 100-120 V AC and 24 V DC power supply)
  [CE Marking]         (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)
EMC Conformity Standards
  [CE Marking]         (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)
  [C-Tick Marking]     (for 220-240 V AC and 24 V DC power supply)
  [KC Marking]         (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)
Standards for Hazardous Location Equipment
  [CSA Non-Incendive]  (for 100-120 V AC and 24 V DC power supply)
  [FM Non-Incendive]   (for 100-120 V AC, 220-240 V AC and 24 V DC power supply)
  [Type n]             (for 24 V DC power supply)
 CONFIGURATION
 Module configuration
  Power Supply Module (PW481 or PW482 or PW484): Two modules in case of a dual-redundant configuration.
            Power supply to the I/O Modules, and supply power to the transmitters.
            The power supply terminals use M4 screws.
  ESB Bus Interface Slave Module (SB401): Two modules in case of a dual-redundant configuration.
  I/O Modules (*1): Max. 8
    *1: Non-standard components.
 LIMITATIONS OF INSTALLATION AND NOTICES FOR INSTALLATION
For installing I/O modules in node unit, the quantity and allocation are limited. Also, when installing a node unit to
the dedicated cabinet, there are limitations of installation under the ambient operating temperature conditions. When
modules with built-in barriers are installed in any node unit, an insulating partition (Part No. T9083NA) must be
installed.
For details, please refer to “FIO System Overview (for Vnet/IP)” (GS 33K50F10-50E) and “Installation Guidance” (TI
33K01J10-50E).
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation                      GS 33K50F20-50E Sep. 1, 2012-00
<<Contents>> <<Index>>                                                                                                 3
 EXTERNAL DIMENSIONS
 ANB10D, ANB10S ESB Bus Node Unit (Figure of ANB10D)
                                                                                                     Unit: mm
                                                    482.6                                 205
            8.75                                    465.1                                150.6               18.4
            21.3                                     440
            146
       221.5
                                                                       Hole for mounting on a 19-inch rack
           37.75                                                       (4 holes for M5 screws)
                                                                                                             F03E.ai
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation                  GS 33K50F20-50E Dec. 7, 2011-00
<<Contents>> <<Index>>                                                                                                                4
 MODELS AND SUFFIX CODES
Node Unit for Single ESB Bus
                                                                          *1:       If ANB10 is connected to the Optical ESB Bus
                                        Description                                 Node Unit (ANB11), “ISA Standard G3 option
  Model      ANB10S        Node Unit for Single ESB Bus                             and temperature (-20 to 70 °C) option” may be
             -3            Single power supply                                      specified.
                                                                          *2:       Select the option code “/ATDOC” to follow the
             -4            Dual-redundant power supply
                                                                                    ATEX Directive for use in potentially explosive
                1          100 - 120 V AC power supply                              atmospheres.
                2          220 - 240 V AC power supply                    *3:       It must be sure to specify the Option Code
                4          24 V DC power supply                                     “/NDEL” to connect Node Unit with AFV10,
                                                                                    AFV30, AFV40 and AFF50.
                           Basic type with no explosion
                      5                                                Dummy Cover
                           protection
                           With ISA Standard G3 option,                                                    Description
  Suffix               6    temperature (-20 ˚C to 70 ˚C) option,
  Codes                    and no explosion protection (*1)                          ADCV01       Dummy Cover (for I/O Module)
                           With ISA Standard G3 option and no            Model                    Dummy Cover (for Power Supply
                      7                                                              ADCV02
                           explosion protection                                                   Module)
                      E    Basic type with explosion protection
                           With ISA Standard G3 option,                Insulating Partition
                      F    temperature (-20 ˚C to 70 ˚C) option,
                           and explosion protection (*1)                                                       Description
                           With ISA Standard G3 option and              Part No. T9083NA          Insulating Partition
                      G
                           explosion protection
                                                                          Note: When mounting an FIO module with built-in
                           Connector Unit for ESB Bus                           barrier to a node unit, place this part to the 8th
             /CU1N
                           [part No.: S9562FA]                                  slot.
                           Connector Unit with Terminator for
  Option     /CU1T
                           ESB Bus [part No.: S9564FA]
  Codes
             /ATDOC        Explosion Protection Manual (*2)
                                                                        ACCESSORIES AND SPARE PARTS
                           Software License for Node Expansion
             /NDEL                                                        Parts         Parts
                           (*3)                                                                    Description    Quantity    Remarks
                                                                         Names         Numbers
                                                                       Insulating
Node Unit for Dual-Redundant ESB Bus                                                   S9049PM           –            4      Accessory
                                                                       bush
                                        Description
                           Node Unit for Dual-Redundant ESB
  Model      ANB10D
                           Bus                                          ORDERING INFORMATION
             -4            Dual-redundant power supply                 Specify the model and suffix codes.
                                                                       For selecting the right products for explosion protection,
                  1        100 - 120 V AC power supply
                                                                       please refer to TI 33Q01J30-01E without fail.
                  2        220 - 240 V AC power supply
                  4        24 V DC power supply
                           Basic type with no explosion                 TRADEMARKS
                      5
                           protection                                  • CENTUM and Vnet/IP are registered trademarks of
                           With ISA Standard G3 option,                  Yokogawa Electric Corporation.
  Suffix               6    temperature (-20 ˚C to 70 ˚C) option,       • Other product and company names appearing in this
  Codes                    and no explosion protection (*1)              document are trademarks or registered trademarks of
                           With ISA Standard G3 option and no            their respective holders.
                      7
                           explosion protection
                      E    Basic type with explosion protection
                           With ISA Standard G3 option,
                      F    temperature (-20 ˚C to 70 ˚C) option,
                           and explosion protection (*1)
                           With ISA Standard G3 option and
                      G
                           explosion protection
                           Connector Unit for ESB Bus
             /CU2N
                           [part No.: S9562FA (2 pieces)]
                           Connector Unit with Terminator for
  Option     /CU2T         ESB Bus
  Codes                    [part No.: S9564FA (2 pieces)]
             /ATDOC        Explosion Protection Manual (*2)
                           Software License for Node Expansion
             /NDEL
                           (*3)
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation                                   GS 33K50F20-50E June 12, 2013-00
Subject to change without notice.