400 KLD STP

The document proposes a 400 KLD sewage treatment plant using BioCleaner systems. It would include 3 aerobic tanks, an upflow sand filter, 3 BioCleaner units, 3 aerolifts to meet discharge standards. The BioCleaner units use specialized microbes to treat wastewater in an efficient and cost effective manner.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views10 pages

400 KLD STP

The document proposes a 400 KLD sewage treatment plant using BioCleaner systems. It would include 3 aerobic tanks, an upflow sand filter, 3 BioCleaner units, 3 aerolifts to meet discharge standards. The BioCleaner units use specialized microbes to treat wastewater in an efficient and cost effective manner.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 10

400 KLD STP Proposal

Prepared for:

Prepared by:

June 6, 2022

www.Biocleaner.com
2550 Corporate Place, Suite C-101 | Monterey Park, California 91754 | USA | 323-981-0797
June 6, 2022

Dear Sir/Ma’am

We are pleased to submit our proposal to you for the 400 KLD STP with the
use of our BioCleaner system, to treat the following waste stream; so that our
BioCleaner, Inc. system effectively treat water quality parameters to meet government
2550 Corporate Place Suite C101
Monterey Park, CA 91754 standards.
T: 323 981 0797
F: 323 981 0797
info@biocleaner.com Our BioCleaner systems are environmentally friendly, cost-effective, and
www.biocleaner.com efficient. Our units, and the microbes used within them, can be specifically
designed and catered to your existing needs, financial circumstances, and
environmental issues. The system has been granted the “Green Patent A” by
the US Patent Agency for new and progressive environmental technologies.

We guarantee your satisfaction with our product and we look forward to doing
business with you.

I have attached a proposal for your approval and use.

Sincerely yours,

Tony Zamudio

Applications Engineer
Executive Summary
Objective
- Meet Government Discharge Standards
- No Odor
- No Sludge

Parameters
We have created this proposal under the following assumptions gathered from the provided data.

We understand that the following are the current practices for the proposed Wastewater
Treatment Plant

1. Capacity of the plant is the peak daily flow of 400 m3/day

2. Inlet Parameters

- BOD 300 mg/l

- COD 500 mg/l

3. Target Parameters

- BOD < 20 mg/l

- COD < 50 mg/l


3. Proposed Concrete Tank Dimensions for STP

3 Aerobic Tank 8m x 5m x 4m depth + 1m freeboard

Upflow Sand Filter 5m x 4m x 1m depth + 0.5m freeboard

Proposed Treatment Equipment


3 - 2 Grid Biocleaner Unit
3 – 2 Grid Aerolift

Add Bar Screen

Construct 3 Aerobic, and Sand Filter

Lower 1 Biosix Unit and 1 Aerolift in Aerobic Tank I-III

Pass through Sand Filter for polishing

Add Disinfection Unit

System should be commissioned less than 4 weeks

Aerolift Unit is the Biocleaner Unit without the Seedertube attached


The Biocleaner Unit
The Seeder Reactor
By using a minimal amount of material, our units focus on the SeederTube which contains a
BioSix Microbial Consortium for the most effective cleansing ability and strength.

Figure 1.1 Biocleaner Unit


Air Blower- The Air Blower provides a flow of air to the Unit. The pump is approximately three
(2) horse-power and requires only a minimal amount of energy and power to work.

SeederTube – The SeederTube contains the consortium of good bacteria that will introduce
millions of waste eating microbes into the water system. Either “BioSix” or “Chem 5”.

Within the SeederTube we use a consortium of microbes.


This mix of microbes work together to provide the most efficient team of waste eating bacteria
without any additional production of waste or sludge. The microbes are in a special patented
immobilized state in the form of media. Immobilized state means that the microbes are dormant
when media or microbes have oxygen and nutrients available, it then activates and will start
multiplying. It is the newly produced microbes that will occupy the entire pond and treat and
remove bad bacteria and waste.
400 KLD Proposed Sewage Design Flowchart

Figure 1.2 Proposed Wastewater flow schematic secondary treatment (Plan View) not in scale

8m 8m

5m

Aerobic II Aerobic III


Aerobic I

5m

4m

Sand Filter
Aerobic I Aerobic II

4m 4m

8m
8m
Aerobic III

5m

Biosix Unit
Purchase Budget

Purchase Cost Biocleaner Deliverables


Outright Purchase
Unit Cost in
Qty Unit Items Total
USD
3 unit 2 Grid Seeder Reactor – Biosix $39,000.00 $117,000.00
3 unit 2 Grid Aerolift $5,500.00 $16,500.00

Total $133,500.00

Shipping/Freight fee

TOTAL $133,500.00
Contact Information
We look forward to the opportunity to work with you, we truly believe that our BioCleaner units offer the best possible cost-effective
solution.

We are more than happy to speak with you further about this proposal.