BJ Serie
BJ Serie
A-12
Long sensing distance/BGS reflective/Micro spot type
Features
sensor
Line-up (B)
BGS reflective type Fiber
optic
● Adopts BGS method superior than convergent reflective sensor
minimizing effect of the ambient objects with narrow sensing width Transparent glass
(D)
Transparent glass sensing type / Micro spot type sensing type Proximity
sensor
● Stable sensing for transparent object(LCD, PDP, glass etc) BGS reflective
by BJG30-DDT type (E)
● Easy to check sensing location with visible micro spot(BJN Series) Pressure
sensor
● Detects tiny objects (min. sensing target Ø0.2mm copper wire) (Spot size)
Commonness Ø5.0/4.5/6.5mm
(F)
● Compact size: W20×H32×L10.6mm Rotary
encoder
● Protection structure IP65(IEC standard)
● Light ON/Dark ON selectable(Except BJG30-DDT) (G)
● Sensitivity adjustment VR incorporated(Except BJG3 DDT) Connector/
Socket
● Built-in reverse power polarity, output short, overcurrent protection circuit
● Mutual interference prevention function(Except BGS reflective type) Micro spot type (H)
● Improved noise resistance and minimized effect of inverter disturbance light Temp.
controller
(Spot size) ※Spot is visible with bare eyes
Please read “Caution for your safety” in operation while beam(line) is not.
manual before using. Ø2.0/2.5mm (I)
SSR/
Power
Specifications controller
Type Transparent glass sensing type BGS reflective type Micro spot type (J)
Counter
NPN open collector output BJG30-DDT BJ30-BDT BJ50-BDT BJ100-BDT BJN50-NDT BJN100-NDT
Model
A-13
BJ Series
Feature data
Through-beam type
● BJ15M-TDT-(C)-(P) / BJ10M-TDT-(C)-(P) / BJ7M-TDT-(P)
Parallel shifting characterisitic Angle characteristic
Measuring method Data Measuring method Data
24
20
BJ15M-TDT-(C)-(P)
20 BJ10M-TDT-(C)-(P) BJ15M-TDT-(C)-(P)
BJ7M-TDT(-P) 16
Sensing distance L(m)
Retroreflective type
● lBJ3M-PDT-(C)-(P)
Parallel shifting characterisitic Sensor angle characteristic Reflector angle characteristic
Measuring method Data Measuring method Data Measuring method Data
6.0
5.0 4.5
Sensing distance L(mm)
0 0.0 0.0
160 80 0 80 160 10° 5°0° 5° 10° 40° 20° 0° 20° 40°
ℓ1 ℓ1 Left Center Right Left Center Right
Sensing area (mm) Operation angle(θ) Operation angle(θ)
1600 160
Sensing distance L(mm)
800 Standard
Standard Standard
ℓ1 sensing 1200 ℓ1 sensing ℓ1 sensing 120
target target 600 target
800 80
400
L L L
400 40
200
200 20
0
0 20 10 0 10 20 0
40 20 0 20 40 ℓ1 ℓ1 40 20 0 20 40
ℓ1 ℓ1 ℓ1 ℓ1
Sensing area(mm) Sensing area(mm) Sensing area(mm)
Standard 140
Sensing distance L(m)
A-14
Long sensing distance/BGS reflective/Micro spot type
Feature data (A)
35 60 110
(C)
30 55 100 Door/Area
25 50 90 sensor
45
Sensing distance L(mm)
20 Standard Standard 80
Standard
50 50 controller
30
40 40
(I)
SSR/
20 30 30 Power
controller
20 20
10
10 10 (J)
Counter
0 0 0
White Corrugated Black Rubber SUS PCB Acryl White Corrugated Black Rubber SUS PCB Acryl White Corrugated Black Rubber SUS PCB Acryl
paper cardboard paper (black) (green) (transparent) paper cardboard paper (black) (green) (transparent) paper cardboard paper (black) (green) (transparent)
Sensing target(material) Sensing target(material) Sensing target(material) (K)
Timer
meter
50 50
30
40 40 (M)
Tacho/
20 30 30 Speed/ Pulse
meter
20 20
10 (N)
10 10 Display
unit
0 0 0
White Red OrangeYellowGreen Blue Navy Violet Black White Red OrangeYellowGreen Blue Navy Violet Black White Red OrangeYellowGreen Blue Navy Violet Black
(O)
Sensing target(colored paper) Sensing target(colored paper) Sensing target(colored paper) Sensor
controller
Connections (P)
Switching
power
● Through-beam type ● Retroreflective type ● Diffuse/Narrow beam/ supply
A-15
BJ Series
Main circuit
(Black)output Over Max.100mA
current
+ 12-24VDC protection + 12-24VDC
Over - ±10% (Black)output
current Max.100mA - ±10%
protection Load
(Blue)0V (Blue)0V
Operation mode
Operation mode Light ON Dark ON
Received light Received light
Receiver operation
Interrupted light Interrupted light
Operation indicator ON ON
(red LED) OFF OFF
ON ON
Transistor output
OFF OFF
32
32
25
25
15
15
M8 M8
2.7
3
Cable: ø3.5, 2m
<Emitter> <Receiver> <Emitter> <Receiver>
32
25
25
8
8
15
15
2.7
Cable: ø3.5, 2m M8
of receiver
24.6
Optical axis
of emitter
35
25
32
35
18
Stability indicator(green)
16.7
20
8.5
of receiver M3Bolt M8
Optical axis
of emitter 24.6 29.5
25
32
8
42.5
15
2.7
A-16
Long sensing distance/BGS reflective/Micro spot type
(A)
● Reflector ● Bracket A ● Bracket B(sold separately) Photo
electric
(accessory:MS-2A, sensor
1.2
3
(C)
14
Door/Area
8
sensor
36 14
60.5
52
M3 Bolt 22 8
26.5 ø3.4 (D)
Proximity
sensor
R25
2.5
R25
34 2-ø3.8 (E)
42.5
18
25
35
6
Pressure
40.5 8.5 sensor
12.5
1.2
(F)
Rotary
10° 20° encoder
(G)
Connector/
Socket
(I)
Stable High Stable High SSR/
light ON area Power
light ON area controller
Unstable
light ON area (J)
Operation Counter
Unstable Incident level Incident
operation area light light
Unstable Operation
level light OFF area level
level (K)
Timer
Stable Stable
light OFF area light OFF area (L)
Low Low Panel
meter
Stability
Stability indicator ON
indicator ON
(green LED) OFF (M)
(green LED) OFF Tacho/
Operation ON Speed/ Pulse
Operation ON indicator meter
indicator Light ON OFF
Light ON OFF (red LED)
(red LED) operation (N)
operation ON
ON Transistor Display
Transistor output OFF unit
output OFF
(O)
※The waveforms of “Operation indicator” and “Transistor output” are for Light ON operation. Sensor
controller
They are opposite operation for Dark ON operation.
(P)
Switching
power
(Q)
Stepping
For mounting Optical axis adjustment motor&
Driver&Controller
A-17
BJ Series
● Retroreflective type Sensitivity adjustment
1.Place the sensor and the reflector
Order Position Description
facing each other and supply the Adjust
power. Right/Left
(A) Turn the adjustment VR to the right of
2.After adjusting the position of the min. and check position(A) where the
1
sensor and reflector and check operation indicator is turned ON in “Light
their stable indicating range, MIN. MAX. ON status”.
Reflector
mount them in the middle of the Turn the adjustment VR more to the right
range. (None or sensing target Adjust Up/Down of position(A), check position(B) where
status) (A) (C)
the operation indicator is turned ON. And
3.After mounting this unit, check the operation of the sensor turn the adjustment VR to the left, check
and in both status. (None or sensing target status) position(C) where the operation indicator
2
is turned OFF in “Light OFF status”.
(B)
※If the operation indicator is not turned
● Diffuse/Narrow beam/BGS reflective type MIN. MAX.
ON although the adjustment VR is
turned to the max. position, the max.
After place a sensing target, adjust
position is (C).
the sensor to up or down, right or
Set the adjustment VR at the center
left. Optimal of (A) and (C). To set the optimum
Then, fix the sensor in the center sensitivity
sensitivity, check the operation and
of position where the indicator is Sensing
target (A) (C) lighting of stability indicator with
operating. 3
sensing target or without it. If the
stability indicator is not turned ON,
MIN. MAX. please check the sensing method again
● Object(Copper wire) detection <Micro spot type> because sensitivity is unstable.
[Figure 1] [Figure 2] ※No sensitivity adjustment function available for BJG30-
When copper DDT models.
wire is moved. Approx. 0 to 15°
Light ON status Light OFF status
Through-
Copper
wire Copper beam
wire type Emitter
Sensing
Receiver
Emitter Receiver target
Diffuse/
Narrow
beam/ Sensing
BGS Sensor target
Background Background
reflective object object
A-18