INTEGRATED MANAGEMENT SYSTEM Record LIV-STLR-(STLP001-
No. NDTP007)-IRRTX-001
(QMS, EMS, OH&SMS)
Inspection Report for Radiography Inspection (X- Date: 15/10/2021
rays)
Location
Project : CGD STEEL PIPELINE NETWORK AZAMGARH GA.
: M/s TORRENT GAS PVT. LTD.
Client
TPIA :M/s ICS
Contractor :M/s AAACPL
GA Name : AZAMGARH Report :
Location : Manduri Azamgarh No.
Chainage No
Reference standard
Radiation :X-RAY Date :15/10/2021
source
Film type : D7 WPS No. :02
Type of Penetrameter :DIN 10 ISO 16 Density :1.8 TO 3.5
Sensitivity :2% Method :DWSI
Pipe Size & :12X6.4 MM API 5L Grx52 3LP
Specification
FFD : 12”
Identification Welder Acceptance Type of
Sr. Observation Remarks
No. No. Repair
KM Joint Segment RT Contractor TPI
No. Agency
A-B Uc ACC ACC ACC
B-C 04 Uc,Con ACC ACC ACC
01 KM-08 VJ-01 C-D Slag,Spatter ACC ACC ACC
D-A 05 Uc ACC ACC ACC
A-B Uc ACC ACC ACC
02 KM-08 VJ-02 B-C 04 Uc,Con ACC ACC ACC
C-D Spatter ACC ACC ACC
D-A 05 Con,Uc,Spatter ACC ACC ACC
A-B Uc,Con,Slag ACC ACC ACC
03 KM-08 VJ-03 B-C 04 Uc,Con ACC ACC ACC
C-D Spatter ACC ACC ACC
D-A 05 Spatter,Ep ACC ACC ACC
A-B Uc,Slag ACC ACC ACC
04 KM-08 VJ-04 B-C 04 Uc ACC ACC ACC
C-D Spatter ACC ACC ACC
D-A 05 Fm,Uc ACC ACC ACC
PROGRESS
TODAY PREVIOUS CUMULATIVE
ACCEPTED JOINT (Nos) 04
REPAIR JOINT (Nos)
REPAIR ACCEPTED JOINT(Nos)
CONTRACTOR TPIA CLIENT
Sign
Name
Date
Format No / Rev. No: LIII-STLF-
(STLP001-NDTP007)-IRRTX- Prepared By Reviewed By Approved By
002 / 00
Designation Cluster IMS Coordinator
Cluster MR/DMR GA MR/MR
/AMR