Timers RTE Series
RTE series part numbers are composed of 5 part number codes. When ordering a RTE series part, select one code from each category.
Example: RTE-P12-AC120V
RTE P 1 2 AC120V
➀ Series ➁ Terminal ➂ Function ➃ Time Range ⑤ Input Voltage
Style Group Group
G
Part Number List
Part Numbers
Part No.
Mode of Operation Time Range Pin Blade
0.1 seconds to 10 minutes RTE-P11 RTE-B11
ON-Delay/Interval
0.1 minutes to 10 hours RTE-P12 RTE-B12
0.1s to 10 minutes RTE-P21 RTE-B21
OFF-Delay/One-Shot
0.1 minutes to 10 hours RTE-P22 RTE-B22
www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC G-9
Timers RTE Series
Timing Diagrams
Interval:
When power is applied to the input terminals, the output contacts instantly transfer and the time delay period begins. At the end of the time delay period, the output
contacts de-energize. Removing power prompts a reset.
(Terminal No.) On
On Interval (RTE-P1, RTE-B1) Pin Blade Off
Timer Power (2-7) (A-B)
Power Off
Delayed NC Contacts (1-4) (7-1) Off On
On
Delayed NO Contacts (1-3) (7-4) Off
Time Delay Off
Delayed NC Contacts (8-5) (9-3) Off On
Load
On
Delayed NO Contacts (8-6) (9-6) Off
G On Indicator
Lighted
Lighted
OUT Indicator
Set Time
One-Shot:
Power must be applied at all times to the input terminals. On momentary or maintained closure of a normally open control signal switch, the output contacts transfer and
the time delay period begins. At the end of the delay period, the output contacts transfer back to the original positions. The timer is then ready for the next timing cycle.
On (Terminal No.) On
Single-Shot (RTE-P2, RTE-B2) Pin Blade
Power Off
Off Timer Power (2-10) (A-B)
Control Signal (5-6) (2-5) On Off
G-10 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC
Timers RTE Series
SFA-203
RTE-P11
8-Pin Fingersafe Socket SR2P-05C
RTE-P12
RTE-P21
11-Pin FingerSafe Socket SR3P-05C
RTE-P22
RTE-P21
11-Pin Screw Terminal SR3P-06
RTE-P22 SFA-202
RTE-B11
RTE-B12
11-Blade Screw Terminal SR3B-05
RTE-B21
RTE-B22
Socket
SR3P-05 Hold Down Spring
SFA-203
Socket
SR2P-06 Hold Down Spring Once installed into the sockets, the
SFA-202 hold-down springs cannot be removed.
www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC G-11
Timers RTE Series
RTE-P11
8-Pin Solder Terminal SR2P-51
RTE-P12
SFA-402
RTE-P21
11-Pin Solder Terminal SR3P-51
RTE-P22
RTE-B11
11-Blade RTE-B12 SR3B-51
Solder Terminal RTE-B21
RTE-B22
Part Numbers: Flush Panel Mount Adapter and Sockets that use an Adapter
Accessory Description Appearance Use with Part No.
G
Panel Mount Adaptor for flush panel mounting All RTE timers RTB-G01
Adapter RTE timers
RTE-P11
8-pin screw terminal SR6P-M08G
RTE-P12
RTE-P21
11-pin solder terminal SR6P-S11
RTE-P22
No hold down clips are available for flush panel mounting applications.
G-12 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC
Timers RTE Series
Instructions
Each RTE series electronic timer is available with two functions (operation
modes) and eight time ranges. Start by determining which timing function RTE-P21-AC120V
and what time range suits your application.
Function Group
Bend the faceplate slightly and pop out the bottom edge (figure 1). Figure 1
2. Timing Function Selection Face Plate
Select the function by moving the DIP switch to the right or left position (Fig-
ure 2). Refer to the table below noting that the function group is the first digit
in the part number. After the face plate is replaced, the DIP switch will be vis- Bottom Slot
ible through the window if it is in the left position. (This is helpful for deter-
mining in which mode the timer is set, without removing the faceplate.)
1
Digital G
Time Range Programming Switch
1. Time Range Selection
Front View
Select the appropriate timer range by rotating the digital switch (figure 2).
Refer to the table below and note that the time range group is the second
digit in the part number.
Digital Switch Setting
Time Range
0 (*8) 1** (9) 2 3 4 5 6 7
Group
5 10
1 1s 3s 6s 10s 60s 30s min. min.
1 3 6 10 60 30 5 10 Figure 3
2 min. min. min. min. min. min. hrs. hrs.
Face Plate
Rotate the wheel in the faceplate to correspond with the time range selected 0 6
in the previous step (figure 3). SEC
Time Range Face Plate RTE Time
Time Range Dial
Group Color Disk Unit Range
3. Replacing Faceplate
Bend faceplate slightly and replace on the timer (figure 4). The digital switch
setting should be visible though a window in the faceplate.
www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC G-13
Timers RTE Series
Dimensions
1.404" (36mm)
Ø1.053"
2.340"
(Ø27)
(60mm)
0.702"
0.039" M 3.5 (18mm)
(1mm) 1.287" Terminal Screw M 3.5
0.858" 0.702"
(33mm) (22mm) Terminal Screw
1.287" (18mm)
(33mm)
0.858"
(22mm)
3.59"
(76mm)
2.964"
(92mm)
Ø 0.164" +
2.184"
(Ø 4.2) (56mm) 1.99" (51mm)
+
1.99"(51mm)
+
M 3.5
(2mm)
0.078"
G-14 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC