Typical Apartment Type 1A - Lighting Layout Typical Apartment Type 2F - Lighting Layout

The document discusses electrical wall outlets and light fittings for a building project. It notes the outlets must comply with disability access requirements and be approved by the architect. It also states all light fittings must comply with targeted green star credits.

Uploaded by

batopotcholo03
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views1 page

Typical Apartment Type 1A - Lighting Layout Typical Apartment Type 2F - Lighting Layout

The document discusses electrical wall outlets and light fittings for a building project. It notes the outlets must comply with disability access requirements and be approved by the architect. It also states all light fittings must comply with targeted green star credits.

Uploaded by

batopotcholo03
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A B C D E F G H I J K L M N

5/04/2024 1:15:09 PM
DRAWINGS NOTES:
1. FINAL MOUNTING OF ALL WALL OUTLETS SHOULD BE COMPLIED WITH DDA REQUIREMENTS AND
1

1 1
ARCHITECTURE APPROVAL.
2. ALL ELECTRICAL WALL OUTLETS' HEIGHT, COLOR AND COORDINATION WITH WALL FINISHING SHOULD BE
REVIEWED AND APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION.
3. ALL LIGHT FITTINGS SHOULD BE COMPLIANT WITH TARGETED GREEN STAR CREDITS.
2

2
DL1
3g
DL1 DL1
EF
DL1 DL1
2g
DL1

DL1 DL1
2g
3

3
DL1

LED1
DL1 DL1

LED1
EF DL1 2g
DL1
DL1 DL1

DL1 EF
DL1 DL1
DL1 EF
DL1
DL1 DL1 2g
4

4
DL1 DL1 DL1
2g
DL1

DL1 2g DL1

DL1

EF
DL1
DL1
DL1
5

5
DL1

TYPICAL APARTMENT TYPE 1A - LIGHTING LAYOUT TYPICAL APARTMENT TYPE 2F - LIGHTING LAYOUT
1 : 50 1 : 50
6

6
7

7
DL1
EF
2g
8

8
2g LED1
3g

DL1
DL1 DL1
DL1
EF
DL1 DL1 DL1
DL1 DL1
LED1

EF DL1 DL1 DL1


DL1 DL1
DL1 DL1
DL1
EF
9

9
DL1 DL1
DL1 EF
DL1 2g
2g
EF
DL1 DL1

DL1
DL1 DL1 DL1
DL1 DL1 DL1
DL1
4g
DL1 2g
DL1

2g
DL1
DL1
10

10
2g
DL1
DL1 DL1
DL1

DL1
DL1 DL1
DL1 DL1 DL1
11

11
TYPICAL APARTMENT TYPE 2A - LIGHTING LAYOUT TYPICAL APARTMENT TYPE 3C - LIGHTING LAYOUT
1 : 50 1 : 50
12

12
Autodesk Docs://IGS VIC_24015_Monument @ 640 Bourke St_R24/IGS_24015_MEFH_CENTRAL_R24.rvt
13

13
0 10 20 30 40 50

AMENDMENTS/REVISIONS AMENDMENTS/REVISIONS
PRELIMINARY
• This drawing was prepared by IGS for the benefit of our client pursuant to a contract which
limits the purpose for which the file may be used and relied upon, other than set out in that CLIENT ARCHITECT CONSULTANT PROJECT DRAWING TITLE
REV REVISION DESCRIPTION BY DATE REV REVISION DESCRIPTION BY DATE contract.
• The copyright of this drawing is vested in IGS and may not be reproduced in whole or part or
P1 50% DD ISSUE RK 05.04.24

used for the purpose of shop drawings without the express permission of IGS.
The use of any measurement, set out or other information derived from this drawing are at
FAR EAST CONSORTIUM MONUMENT MELBOURNE ELECTRICAL SERVICES DRAWN DESIGNED CHECKED SCALE (@ A0) DATE

RK SAB SA As indicated NOV 23


the users own risk. Work to figured dimensions only and do not scale from the drawing.
Contractor to check all dimensions on site prior commencing any work or preparing any shop
drawings.
Phone: +61 3 8609 6600
Address: Level 4, 108 Elizabeth Street, Melbourne,
640 BOURKE STREET, MELBOURNE VIC TYPICAL APARTMENTS - LIGHTING PROJECT No. DRAWING No. REVISION
• This drawing shall be read in conjunction with the architect's and IGS regularly issued
drawings, all relevant details, specifications, codes & regulations.
VIC 3000 Australia
Web: www.igs.com.au 3000 LAYOUT 24015 E310 P1
A B C D E F G H I J K L M N