GENERAL NOTES

This drawing is protected by copyright. This drawing is to be read in


conjunction with the relevant structural, mechanical and electrical drawings.

Dimensions are not to be scaled from this drawing. All works are to be
carried out in accordance with the relevant B.S. and codes of practice and
are also to meet the local authority requirements. The contractor and their
subcontractors are to verify all dimensions on site before making any shop
drawings and before executing the works.

Any discrepancies, either between written dimensions and site dimensions


or between this drawing and other consultants' or suppliers' drawings,
should be brought to the immediate attention of the architect before
ROUND PVC CONDUIT BOX WITH SLAB
NOTES: METALIC EXTENSION RING
executing the works.

N
1. CONTRACTOR TO CARRY OUT AN INSPECTION OF THE SITE AND BRING TO THE ATTENTION CEILING ROSE
30W LED DOWN LIGHT WITH/WITHOUT
OF THE ENGINEER ANY DISCREPANCIES WITH THE SITE CONDITIONS AND THE LAYOUT
GRID HANGER SUPPORT DIFFUSER AS SPECIFIED. DIMENTION TO BE 59
0 59
DRAWINGS AND RESOLVE THE SAME BEFORE COMMENCEMENT OF WORK. CEILING SLAB
0
UP

PVC FLEXIBLE CONDUIT SUITABLE TO INSTALL ON TILE CEILING

100
2. THIS DRAWING IS NOT TO BE SCALED. STATED DIMENSIONS ONLY ARE TO BE CONSIDERED (HEAT RESISTING) (i.e. 600 X 600mm) - - -D RI V E W A Y - - -

PVC CONDUIT CAST - - - - P A R K I N G AREA - - - -


GREEN

3. INSTALLATION TO COMPLY WITH LOCAL AUTHORITY WIRING REGULATIONS. IN CEILING SLAB

- - - -PARKING - - - -
NOTE: OPEN TO SKY

CEILING ROSE ADJUSTABLE CLIP


4. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND SAME MOUNTING ARRANGEMENT EXPANSION SCREW
COORDINATED SERVICE DRAWING. AND BOLT
- - -D RI V E W A Y - - -
- - - - P A R K I N G AREA - - - -

IS APPLICABLE FOR SURFACE GREEN

PVC FLEXIBLE CABLE IN FLEXIBLE FEMALE


WAITING AREA

5. ALL FINAL CIRCUIT CABLING TO BE SINGLE CORE LSF INSULATED WITHIN GALVANIZED STEEL CONDUITS INSTALLATION CONDUIT (HEAT RESISTING) LIGHT FITTING CLIPS
CONDUIT AND TRUNKING.
CABLE GLAND WITH LOCKNUT
T GRID

100
590
6. FINAL CONNECTIONS TO ALL LIGHT FIXTURES BY SURFACE MOUNTED 3 PIN PLUG IN CEILING RECESSED LUMINAIRE LED FALSE CEILING
ROSE. FINAL CONNECTION BY ALL 3 CORE 2.5 SQmm BUTYL RUBBER FLEX. 600 X 600mm CEILING TILE
FALSE CEILING
7. FINAL FINISHES OF SWITCHES BEING AS PER ARCHITECTURAL SPECIFICATION.
3 TYPICAL ARRANGEMENT OF RECESSED LED LIGHT FITTING
8. LIGHT FITTING TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURES REQUIREMENTS.
2 RECESSED TYPE LED LIGHT FIXTURE INSTALLATION NTS
NTS
(PROVISION IN CEILING)
9. ALL LIGHT FIXTURES TO BE SERVED FROM GALVANIZED STEEL CABLE TRUNKING AT HIGH
LEVEL. NO LIGHTING CIRCUIT TO INSTALLED WITH IN THE FLOOR VOID CABLE CONTAINMENT.

10. THE LOCATION OF LIGHTINGS ARE DEVELOPED AS PER THE


ARCHITECTURAL DETAILS TO SUITE FLEXIBILITY IN LAYOUT.

11. ALL LIGHT FIXTURE SHALL BE LED TYPE. PVC FLEXIBLE CABLE
LED LIGHT FITTING IN FLEXIBLE CONDUIT
ROUND PVC CONDUIT BOX WITH
METALIC EXTENSION RING
25mm G.I. SADDLE
LED LIGHT FITTING

25mmØ G.I. CONDUIT FALSE CEILING


PVC CONDUIT CAST IN
CEILING SLAB WALL
WALL
CEILING SLAB

OPEN SPACE

OPEN SPACE
25mmØ PVC EMBEDDED
CEILING ROSE
SWITCH SURFACE SWITCH FLUSHED TYPE
CABLE GLAND WITH LOCKNUT MOUNTED TYPE

EDGE OF WALL
EDGE OF WALL

1200

1200
00 2021.12.26 TENDER SUBMISSION iFT

Rev Date Description Drawn


FFL FFL Signature: Date:
APPROVED:
1 TYPICAL ARRANGEMENT OF LED FITTINGS. R.H 2021.12.26
NTS 5 TYPICAL LIGHTING SWITCH SURFACE & FLUSH MOUNTING DETAIL CHECKED: Signature: Date:
NTS P.C.P 2021.12.26
DRAWN BY: Signature: Date:

iFT 2021.12.26
SLAB
GROUND FLL Healthcare Consultant:

FLEXIBLE PVC CONDUIT Eurohealth Systems


Healthcare Consultants
B 301 Dubai Healthcare City
PO Box 8703, Dubai - UAE
Tel: +971.4.4281483 Fax: +971.4.4281482
EMBEDDED PVC CONDUIT
MEP Consultant :
PVC BOX
LED LUMINAIRE DIRECTLY FIXED ON SLAB
EMBEDDED PVC BOX RECESSED TYPE
(SURFACE MOUNTED)
WIRES IN ØX mm CONDUIT LED LIGHT FITTING
DOWN TO LUMINAIRE 3c x 2.5mm HEAT RESISTANT FLEXIBLE CABLE
Client:
WALL (BRICK WORK)
ASTER DM HEALTHCARE
PLUG-IN TYPE CEILING ROSE
FLASE CEILING 25mm PVC
CONDUIT Project:
25mmØ PVC CONDUIT EMBEDDED MEDCARE, KHAWANEEJ
FALSE CEILING WALL
LED LUMINAIRE Dwg Title:
LUMINAIRE BACK BOX SWITCH LIGHTING LAYOUT
BASEMENT FFL
TYPICAL INSTALLATION DETAILS
SCREW FISCHER
Scale: N.T.S A3 Created:

6 GENERAL DETAIL FOR WALL MOUNTED 7 SURFACE MOUNTED TYPE LED LIGHT FIXTURE WITH EXPOSED GI / 8 MOUNTING ARRANGMENT FOR RECESSED LED LIGHTING FIXTURES Job no: DM 2100-16
LED LUMINAIRE CONNECTION DETAIL EMBEDDED PVC CONDUIT NTS
Discipline:
NTS
Issued for:
Drawing number:

EL-01 Revision: 00
GENERAL NOTES
This drawing is protected by copyright. This drawing is to be read in
conjunction with the relevant structural, mechanical and electrical drawings.

Dimensions are not to be scaled from this drawing. All works are to be
carried out in accordance with the relevant B.S. and codes of practice and
are also to meet the local authority requirements. The contractor and their
subcontractors are to verify all dimensions on site before making any shop
drawings and before executing the works.

Any discrepancies, either between written dimensions and site dimensions


or between this drawing and other consultants' or suppliers' drawings,
should be brought to the immediate attention of the architect before
executing the works.

UP

- - -D RI V E W A Y - - -

- - - - P A R K I N G AREA - - - -
GREEN

- - - -PARKING - - - -
OPEN TO SKY

- - - - P A R K I N G AREA - - - -
- - -D RI V E W A Y - - -
GREEN

MALE

RECEPTION DESK
FEMALE
WAITING AREA

WAITING
FEMALE
WAITING AREA(F)
WAITING MALE
DERMA FAMILY MEDICINE RECEPTION
WAITING
RECEPTION AREA CONSULTATION ROOM 1 13.57 SQ.M RG-001
RG-002
DENTAL ROOM 13.55 SQ.M
18.61 sqm RG-015 RG-009
RG-010
RG-017

RECEPTION DESK WAITING AREA(M)

FEMALE
WAITING

EXISTING TREATMENT
ROOM 1
STORAGE PEDIATRIC
ROOM
7.60 SQ.M 13.1 SQ.M
ADA
& compressor

JANITOR
RG-015 ROOM TOILET (M)
Suction

RG-003
Room

2.3 SQ.M 4.0 SQ.M

RG-007
TOILET ADA (F) RG-008

DERMA 4.0 SQ.M


CONSULTATION
RG-011
ROOM 2
14.11 SQM
TREATMENT ROOM 2
RG-016
11.2 SQ.M
TREATMENT ROOM 4
10.5 SQ.M
RG-013 GYNECOLOGY
13.00 SQ.M RG-004
TRIAGE ROOM PHYSIO
7.55 SQ.M ROOM 1
RG-006
TREATMENT / RG-005 7.55 SQ.M
RG-014 TOILET (F)
SAMPLE SERVER ROOM
4.1 SQ.M
COLLECTION ROOM 2.8 sqm RG-005
ROOM # 2 30.12 sqf RG-012
10.89 sqm
117.21 sqf

GROUND FLOOR CLINIC - PLAN


01 00 2021.12.26 TENDER SUBMISSION iFT

Rev Date Description Drawn


LEGEND - LIGHTING Signature: Date:
APPROVED:
INTERNAL LIGHTS R.H 2021.12.26
CHECKED: Signature: Date:
TYPE SYMBOL DESCRIPTION
P.C.P 2021.12.26
20W DECORATIVE LIGHT
DRAWN BY: Signature: Date:

iFT 2021.12.26
18W HANGING PENDANT LED LIGHT
Healthcare Consultant:
Eurohealth Systems
Healthcare Consultants
10W RECESSED DOWN LIGHT B 301 Dubai Healthcare City
PO Box 8703, Dubai - UAE
Tel: +971.4.4281483 Fax: +971.4.4281482

12W RECESSED DOWN LIGHT


MEP Consultant :

15W RECESSED DOWN LIGHT

Client:
10W LED STRIP COVE LIGHT
ASTER DM HEALTHCARE

LIGHTING CONTROLS Project:

1 WAY SWITCHES MEDCARE, KHAWANEEJ


(1G,2G&3GANG)

Dwg Title:
2 WAY SWITCHES

(1G,2G&3GANG) LIGHTING LAYOUT


GROUND FLOOR PLAN
MOTION SENSOR

Scale: 1:100 A3 Created:


OVERRIDE LIGHT SWITCH CONTROL

Job no: DM 2100-16


Discipline:

Issued for:
Drawing number:

EL-02 Revision: 00
GENERAL NOTES
This drawing is protected by copyright. This drawing is to be read in
conjunction with the relevant structural, mechanical and electrical drawings.

Dimensions are not to be scaled from this drawing. All works are to be
carried out in accordance with the relevant B.S. and codes of practice and
are also to meet the local authority requirements. The contractor and their
subcontractors are to verify all dimensions on site before making any shop
drawings and before executing the works.

Any discrepancies, either between written dimensions and site dimensions


or between this drawing and other consultants' or suppliers' drawings,
should be brought to the immediate attention of the architect before
executing the works.

UP

- - -D RI V E W A Y - - -

- - - - P A R K I N G AREA - - - -
GREEN

- - - -PARKING - - - -
OPEN TO SKY

- - - - P A R K I N G AREA - - - -
- - -D RI V E W A Y - - -
GREEN

FEMALE
WAITING AREA

TREATMENT ROOM 2 TREATMENT ROOM 1


9.8 SQ.M 9.8 SQ.M

RF-103 RF-102
RELAXATION ROOM
13.74 SQ.M

RF-104

STAFF
TOILET
2.31 sqm
24.85 sqf

NURSE
STATION
STERILIZATION

TERRACE
ROOM # 10
4.35 sqm
46.8 sqf

WAITING AREA

RF-101

ADMIN ROOM
7.5 SQ.M
BIO MED.
ROOM # 11 RF-105
2 sqm
21.52 sqf

EXISTINGPANTRY
ROOM # 12
5.7 sqm
STORAGE
2.19 sqm
23.56 sqf
61.33 sqf

00 2021.12.26 TENDER SUBMISSION iFT

Rev Date Description Drawn


FIRST FLOOR CLINIC - PLAN APPROVED: Signature: Date:
01 LEGEND - LIGHTING R.H 2021.12.26
CHECKED: Signature: Date:
INTERNAL LIGHTS
P.C.P 2021.12.26
TYPE SYMBOL DESCRIPTION
DRAWN BY: Signature: Date:
20W DECORATIVE LIGHT
iFT 2021.12.26
Healthcare Consultant:
18W HANGING PENDANT LED LIGHT Eurohealth Systems
Healthcare Consultants
B 301 Dubai Healthcare City
PO Box 8703, Dubai - UAE
Tel: +971.4.4281483 Fax: +971.4.4281482
10W RECESSED DOWN LIGHT

MEP Consultant :

12W RECESSED DOWN LIGHT

15W RECESSED DOWN LIGHT


Client:
ASTER DM HEALTHCARE
10W LED STRIP COVE LIGHT

Project:
LIGHTING CONTROLS MEDCARE, KHAWANEEJ
1 WAY SWITCHES
Dwg Title:
(1G,2G&3GANG)

2 WAY SWITCHES
LIGHTING LAYOUT
(1G,2G&3GANG)
FIRST FLOOR PLAN

MOTION SENSOR
Scale: 1:100 A3 Created:

OVERRIDE LIGHT SWITCH CONTROL Job no: DM 2100-16


Discipline:

Issued for:
Drawing number:

EL-03 Revision: 00