This document provides instructions for installing, using, and servicing an electronic module called the UNI-2 for use in potentially explosive atmospheres. It describes the module variants and markings, installation procedures, electrical parameters, and special conditions for safe use.

Uploaded by

Hassan Alvi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
128 views7 pages

Uni-2 22 12 12

This document provides instructions for installing, using, and servicing an electronic module called the UNI-2 for use in potentially explosive atmospheres. It describes the module variants and markings, installation procedures, electrical parameters, and special conditions for safe use.

Uploaded by

Hassan Alvi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

NT IN IECEx - ATEX 20 A

INSTRUCTIONS MANUAL du 21/01/2020

Attachment doc :
UNI-2 - ELECTRONIC MODULE DCCE

Purpose : This manual specifies the installation, use and servicing conditions of the module type UNI-2 for
safety use in potentially explosive atmospheres

1. MARKING:
Regulatory marking allowing the device identification is affixed by engraving or on a specific label including the
following indications:

1.1. For models UNI-2 A0 and E0 variants

Name and address of manufacturer: ALMA (or Alma logo)


13127 VITROLLES

0080
Description of type: UNI-2
Variant, see inside enclosure
(Serial N°)
(Year of construction)
EU-Type examination certificate INERIS 19ATEX0029X
IECEx- Certificate of Conformity IECEx INE 19.0030X
Category II 2 G
Marking code Ex ia op is IIB T3 Gb
Warning WARNING: Do not replace or charge batteries in hazardous area

1.2. For models UNI-2 E1 variant

Name and address of manufacturer: ALMA (or Alma logo)


13127 VITROLLES

0080
Description of type: UNI-2
Variant, see inside enclosure
(Serial N°)
(Year of construction)
EU-Type examination certificate INERIS 19ATEX0029X
IECEx- Certificate of Conformity IECEx INE 19.0030X
Category II 2 G
Marking code Ex ia op is IIB T4 Gb

1.3. For Temperature sensor, liquid sensors and L7 to L9 case

Name and address of manufacturer: ALMA (or Alma logo)


13127 VITROLLES

0080
EU-Type examination certificate INERIS 19ATEX0029X
IECEx- Certificate of Conformity IECEx INE 19.0030X
Category II 2 G

FORM DOC 106 A


NT IN IECEx - ATEX 20 A
INSTRUCTIONS MANUAL du 21/01/2020

Attachment doc :
UNI-2 - ELECTRONIC MODULE DCCE

B2.8 PT100- Temperature sensor -


B2.9 PT100+ Temperature sensor +

2.2.3. B3 : External supply pulse emitter interfaces


Terminal Name Comments
B3.1 Vext + Power external supply +
B3.2 Vext GND Power external supply GND
B3.3 2H00 V+ Pulse emitter supply +
B3.4 2H00 V- Pulse emitter GND
B3.5 2H00 S1 Pulse emitter output N°1
B3.6 2H00 S2 Pulse emitter output N°2

3. USE
Once equipped with batteries and fixed on the turbine body or on the enclosure extension, the electronics are
fonctionnal.
The operating temperature ranges from -20°C to 50°C.
Interfaces with the operator is by the keyboard and LCD display.

4. MAINTENANCE AND SERVICE


Apart from the calibration of counting operations no adjustment or special preventive maintenance is required.
The configuration settings can only be modified after tripping the micro switch located on the electronic board.
Only authorized personnel can modify the settings.
The batterie should be charge and change outside explosive area.
The following batteries shall be in explosive atmospheres.
- Ni-MH battery , size AA, manufacturing by PANASONIC type eneloop Pro

For charge in safe area, only use battery charger manufacturing by ALMA type ALMA Wireless Charger.

Non-working electronic board must be return to ALMA

FORM DOC 106 A


NT IN IECEx - ATEX 20 A
INSTRUCTIONS MANUAL du 21/01/2020

Attachment doc :
UNI-2 - ELECTRONIC MODULE DCCE

2. INSTALLATION INSTRUCTIONS
The UNI-2 is a calculator indicator. It can be combined with four sensors. It can either be installed on a turbine
or with an enclosure extension.
An O-Ring provides sealing between the turbine or the enclosure extension. Ensure that the ring is in
place and has been lubricated before tightening the screw. The seal must be at least IP20.
The sensors are connected to the UNI-2 either inside the enclosure or through cable glands and terminal
blocks.
Maximum cable length from UNI-2 models to temperature sensors, liquid sensors and L7 to L9 case doesn’t
exceed 10 meters.

2.1. Variants:
The variant marking of the UNI-2 is readable inside the enclosure on a label plate comprising a letter and a
number defining the variant used.
Variants Comments Battery

A0 Autonomous mode With


External supply with With
E0 battery backup
External supply only Without
E1 (No batteries in the device)

2.2. Wiring :

2.2.1. B1 : Pulse emitter input


Terminal Name Comments
B1.1 2B00 GND Pulse emitter ground
B1.2 2B00 L2-
Coil N°2
B1.3 2B00 L2+
B1.4 2B00 L1-
Coil N°1
B1.5 2B00 L1+

2.2.2. B2 : Liquid detectors and temperature sensor input


Terminal Name Comments
B2.1 DL2 Out Liquid detector N°2 Output
B2.2 DL2 V- Liquid detector N°2 Supply -
B2.3 DL2 V+ Liquid detector N°2 Supply +
B2.4 DL1 Out Liquid detector N°1 Output
B2.5 DL1 V- Liquid detector N°1 Supply -
B2.6 DL1 V+ Liquid detector N°1 Supply +
B2.7 GND Temperature sensor Ground

FORM DOC 106 A


NT IN IECEx - ATEX 20 A
INSTRUCTIONS MANUAL du 21/01/2020

Attachment doc :
UNI-2 - ELECTRONIC MODULE DCCE

5. ELECTRICAL PARAMETERS

5.1. Output parameters on terminal B1


Terminal Uo (V) Io (mA) Po (mW) Co (µF) Lo (H)
B1.1 to B1.5 6.3V 2.65 4.17 720 20.13
5.2. Output parameters on terminal B3
Terminal Uo (V) Io (A) Po (W) Co (µF) Lo (µH)
B3.3 vs B3.4
B3.5 vs B3.4 13.2* 0.428* Po* 5.8 741.3
B3.6 vs B3.4
(*) : Characteristics of the Ex ‘i’ power supply from block B3.1 and B3.2

5.3. Input parameters on terminal B3


Terminal Ui (V) Ii (A) Pi (W) Ci (µF) Li (µH)
B3.1 and B3.2 13.2 0.428 1.0224 5.8 776.3

6. SPECIAL CONDITIONS FOR SAFE USE


The using ambient temperature range of the electronic modules is comprised between -20°C and +50°C,
For variants A0 and E0 of electronic module type UNI-2, the apparatus must be powered by two batteries
connected in series from manufacturing Panasonic type Eneloop pro AA (size AA).
Batteries charging must be performed outside hazardous area with wireless charger from manufacturing
ALMA type ALMA Wireless charger.
The voltage source connected to terminals B3-1 and B3-2, for variants E0 and E1 of electronic module type
UNI2 must be from a certified type for using in gas groups IIC or IIB and its output circuit recognized as
intrinsically safe. Electrical output parameters of this voltage supply have not to exceed maximum input
characteristics defined into chapter 5.3 above.
Apparatuses connected to terminals referenced B1 and B3.3 to B3.6, from electronic module type UNI-2 (all
variants), must be of a certified type for using in gas group IIB and their association compatible from intrinsic
safety point of vue.

Maximum cable length from UNI-2 models to temperature sensors, liquid sensors and L7 to L9 case must
not exceed 10 meters.

During the installation, the user will have to take precautions in order to avoid any possible shock.

7. ATTACHED DOCUMENTS

− Each device comes with the original version of the instruction manual of the device certified according to
EN IEC 60079-0: 2018 ; IEC 60079-0: 2017 Edition 7 ; EN 60079-11: 2012 ; IEC 60079-11: 2011 Edition 6
IEC / EN 60079-28: 2015 standards
The documents will be translated in the language of the country of use.

FORM DOC 106 A


Dispositif permettant
le blocage du couvercle
en position ouverte
sur le FLEXICOMPT+
Communication
Infra-rouge
Vis CHC M5

270
(Inox A4) de fixation

90

146
D tecteur ouverture

e de
et fermeture du couvercle

labl
R g
Resistant aux UV et Hydrocarbures

Cinq touches

89

Point de fixation du MPLS

Came d'arr t
du couvercle (r glable)
126*
Joint en Viton

93
65*
81*

35 5.7

Emplacement * Les c tes d'encombrement et


Chargeur induction de fixation du fond d'UNI sont
identiques l'UNI.
160*
Le chargement et/ou le remplacement des batteries doit s'effectuer hors atmosph res explosible
- Masse : ~ 600g,
- Mati re du coffret et du couvercle : Alliage d'aluminium et POM, Versions
- Traitement : Alimentation Version CI058 Code ensemble
- Couvercle : Peinture couleur RAL5010 r sistant aux Batteries A0 2749
Externe E0 3020
hydrocarbures,
- Boitier : Anodis Noir,
- Temp rature d'utilisation : de -20 C +50 C Article associ s
D signations Plans Codes
- Attestation d'examen UE de type N : INERIS 19ATEX0029X
Emetteur bobine type 2B00 PPV025 8147
- Certificat de conformit IECEx N : IECEx INE 19.0030X Emetteur type 2H00 PPV069 8145/8146
- M trologie L gale CEV N : LNE-25603 Emetteur d'impulsions param trable type 2HP0 PPV117 1406/1775
- Protection : IP65 Sonde de temp rature type CT1001 PPV042 8151
Service PLAN DE PRESENTATION DFV146 Description de la modification N 826 :
D veloppement Suppression des plombs
13127 Vitrolles Electronique de comptage
N de DEV : 949h Code : 2749/3020 UNI-2
N de plan associ du dossier CET concern
M tro : LNE-25603
949h PPV146 F.1 4 /6 Modifi le : 12/12/2022 par CC
v rifi par
CHR
ATEX: IECEx INE 19.0030X / ATEX 0029 X N Dev N de plan Rev Folio Cr e le : 14/03/2019 CC SR
Device that blocks
the lid in open position
on FLEXICOMPT+
Infrared

0
Communication

7
M5 CHC secutrity screw

to 2
(Inox A4)

90
om
Detector opening

r
ble f
and closing the lid

usta

146
A dj
Resistant to UV and Hydrocarbons

Five Key

89

MPLS attachment point

Stop cam for cover (adjustable)


126*
Viton O-ring

93
65*
81*

35 5.7

Location
Induction charger
*Overall dimensions and bottom of
UNI fastening are identical of UNI
160*

Charging and/or replacement of batteries should be carried out outside explosive area
- Mass : ~ 600g,
- Box and lid material : Aluminium alloy and POM, Variant
- Material finishing : Power supply Variant CI058 Product Code
Battery A0 2749
- Lid : hydrocarbons resistant RAL5010 color paint,
Wire E0 3020
- Box : Black anodized,
- Temperature range : from -20 C to +50 C Associated items
- UE type examination certifcate N : INERIS 19ATEX0029X Designation Plan Code
- IECEx certifcate of conformity N : IECEx INE 19.0030X 2B00 Pulse emitter PPV025 8147
- Legal metrology CEV N : LNE-25603 2H00 pulse emitter PPV069 8145/8146
2HP0 Configurable pulse transmitter PPV117 1406/1775
- Protecion : IP65
CT1001 temperature sensor PPV042 8151
Service PRESENTATION DRAWING DFV146 Description of amendment N 826 :
Development Removing lead seals
13127 Vitrolles Metering electronic device
DEV N : 949h Code : 2749/3020 UNI-2
Drawing N associated with the related CET file
Metro : LNE-25603
949h PPV146 F.1 5 /6 Modified on : 12/12/2022
by
CC
verified by
CHR
ATEX: IECEx INE 19.0030X / ATEX 0029 X Dev N Drawing N Rev Folio Created on : 14/03/2019 CC SR
DECLARATION UE DE CONFORMITE
EU DECLARATION OF CONFORMITY
Fabricant / Manufacturer : ALMA, Bâtiment B4 la bastide blanche, 13127 Vitrolles, France.
Appareil / Device : Calculateur
Type / Type: UNI-2
Déclarons que ce matériel satisfait aux exigences des documents suivants :
Declare that this material is in conformity with requirements of the following documents:
2014/30/UE Directive CEM
2014/30/EU EMC Directive
EN 55032 et 55024 Emissions et immunité ATI (Appareils de Traitement de l’Information)
Disturbance and immunity ITE (Information Technology Equipment)
EN 55016-2-3 Perturbations émises rayonnées
Emission of radiation interference
EN 61000-4-2 Décharges électrostatiques
Electrostatic discharge (ESD)
EN 61000-4-3 Immunité rayonnée
Radiated immunity
EN 61000-4-4 Immunité aux transitoires électriques rapides en salves
Electrical fast transient / burst immunity
EN 61000-4-6 Immunité aux perturbations conduites
Immunity to conducted disturbances

2014/34/UE ATEX
2014/34/EU ATEX Directive
NF EN 60079-0:2018 Atmosphères explosives - Matériel - Exigences générales
Explosive atmospheres. Equipment - General Requirements
NF EN 60079-11:2012 Atmosphères explosives - Protection du matériel par sécurité intrinsèque "i"
Explosive atmospheres - Equipment protection by intrinsic safety "i"
NF EN 60079-28:2015 Rayonnement optique
Optical radiation
Il a fait l'objet d'une attestation d'examen UE de type : INERIS 19 ATEX 0029X et il a été fabriqué sous assurance
de la qualité.
It has been the object of an UE attestation type: INERIS 19 ATEX 0029X and It was manufactured under quality
assurance.
Notre système qualité a été évalué par l’INERIS organisme n°0080, notifié sous le n°03 ATEX Q407 et résidant Parc
technologique Alata-BP 2-F-60550 Verneuil en Halatte
Our quality system has been assessed by INERIS body n°0080, notified under n° 03 ATEX Q407 and residing Parc
technologique Alata-BP 2-F-60550 Verneuil en Halatte
La présente déclaration de conformité est établie sous la seule responsabilité d’ALMA
This declaration of conformity is issued under the sole responsibility of the ALMA.

Ainsi ce matériel est conforme aux directives européennes.


This materiel complies with european directives.
Fait à Boissy St Léger le 30 Juillet 2021,
Signed at Boissy St Léger on July, 30 2021,

François DOS-SANTOS
Directeur Technique / Technical Director

Siège Social / Head office  4A, Boulevard de la Gare  Porte 1  F-94470 Boissy St. Léger
Ph. +33 1 45 69 44 70  Fax +33 1 45 69 16 02  info@alma.tm.fr  www.alma-alma.fr
SAS au capital de / Capital of 1 000 000 €  R.C.S. Créteil 331 983 163

You might also like