Catalogo Parker Autoclave 1
Catalogo Parker Autoclave 1
O.D. *Rated
Pressure
Tube Cv Valve
Rating
Size (full Stem
psi (bar)
In (mm) open) Type
60VM9071-O2S
Air To Open
Piston Activated
Note: For outdoor service actuators, please see main catalog.
4
TOC
For example, a 9/16” 20SM valve can operate to 10,700 psi with 100 psi air pressure using the
Medium Piston (-C1S) or 20,000 psi MAWP with the Heavy (-C2S) actuator. or can operate to
20,000 psi using only 65 psi air pressure with the Extra Heavy Duty Single Stage Piston (-HC1S).
10V6071-C1S
Air To Close
Piston Activated
Medium (-C1S) Heavy (-C2S) Extra Heavy Single Stage (-HC1S) Extra Heavy Two Stage (-HC2S)
O.D.
Valve Series Tube System Air System Air System Air System Air
in. (mm) Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure
psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
9/16 8,600 100 15,000 75 15,000 60 15,000 35
(14.30) (593) (6.9) (1035) (5.2) (1035) (4.2) (1035) (2.4)
3/4 15,000 100 15,000 100 15,000 50
- -
(19.10) (1035) (6.9) (1035) (69) (1035) (3.5)
15SM
1 6,300 100 8,500 95 10,000 55
- -
(25.40) (434) (6.9) (586) (6.55) (690) (3.79)
1.5 10,000 90
- - - - - -
(38) (690) (8)
1/4 20,000 95 20,000 50
- - - -
(6.35) (1380) (6.5) (1380) (3.5)
3/8 19,000 100 20,000 55
- - - -
(9.53) (1310) (6.9) (1380) (3.8)
9/16 10,700 100 20,000 85 20,000 65
20SM - -
(14.30) (734) (6.9) (1380) (5.9) (1380) (4.48)
3/4 6,100 100 13,600 100 19,000 100 20,000 50
(19.10) (421) (6.9) (938) (6.9) (1310) (6.90) (1380) (3.4)
1 8,800 100 12,500 100 20,000 75
- -
(25.40) (607) (6.9) (862) (6.90) (1380) (5.1)
1 30,000 80
30SC - - - - - -
(25.40) (2068) (5.5)
1/4 30,000 55 30,000 30
- - - -
(6.35) (2068) (3.8) (2068) (2.0)
3/8 30,000 75 30,000 40
30VM - - - -
(9.53) (2068) (5.2) (2068) (2.8)
9/16 30,000 75 30,000 40
- - - -
(14.30) (2068) (5.2) (2068) (2.8)
9/16 40,000 90 40,000 45
40VM - - - -
(14.30) (2758) (6.2) (2758) (3.1)
1/4 60,000 75 60,000 40
- - - -
(6.35) (4137) (5.2) (4137) (2.8)
3/8 60,000 75 60,000 40
60VM - - - -
(9.53) (4137) (5.2) (4137) (2.8)
9/16 60,000 90 60,000 45
- - - -
(14.30) (4137) (6.2) (4137) (3.1)
Notes: Actuator Selection Guide (choose actuator based on available air pressure).
5
15SM Valves replace 10SM Valves and are rated to 15,000 psi (1035 bar).
TOC
For example, a 9/16" 20SM valve can operate to 9,800 psi with 100 psi air pressure using the
Medium Piston (-O1S) or 15,700 psi MAWP with the Heavy (-O2S) actuator. or can operate to
20,000 psi using only 85 psi air pressure with the Extra Heavy Duty Single Stage Piston (-HO1S).
20SM6872-O1S
Air To Open
Piston Activated
Air to Open: Actuator Selection Guide
Medium (-O1S) Heavy (-O2S) Extra Heavy Single Stage (-HO1S) Extra Heavy Two Stage (-HO2S)
O.D.
Valve Series Tube System Air System Air System Air System Air
in. (mm) Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure
psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
9/16 12,000 80 15,000 80 15,000 55
- -
(14) (830) (5.5) (1035) (5.5) (1035) (4)
3/4 12,000 100 15,000 75
- - - -
(19) (830) (7) (1035) (5)
15SM
1 6,500 100 10,000 85
- - - -
(25) (448) (7) (690) (5.9)
1.5 9,000 100
- - - - - -
(38) (621) (7)
1/4 20,000 95 20,000 50
- - - -
(6.35) (1380) (6.6) (1380) (3.4)
3/8 18,250 95 18,250 50
- - - -
(9.53) (1258) (6.6) (1258) (3.4)
9/16 9,800 95 15,700 75 20,000 85 20,000 55
20SM
(14.30) (676) (6.6) (1082) (5.1) (1380) (5.86) (1380) (3.8)
3/4 6,000 75 15,000 100 20,000 80
- -
(19.10) (414) (5.1) (1034) (7) (1380) (5.5)
1 10,000 100 20,000 100
- - - -
(25.40) (690) (7) (1380) (7)
1 30,000 100
30SC - - - - - -
(25.40) (2068) (7)
1/4 30,000 75 30,000 40
- - - -
(6.35) (2068) (5.2) (2068) (2.8)
3/8 30,000 95 30,000 50
30VM - - - -
(9.53) (2068) (6.6) (2068) (3.5)
9/16 30,000 95 30,000 50
- - - -
(14.30) (2068) (6.6) (2068) (3.5)
9/16 40,000 100 40,000 55
40VM - - - -
(14.30) (2758) (6.9) (2758) (3.8)
1/4 60,000 95 60,000 50
- - - -
(6.35) (4137) (6.6) (4137) (3.5)
3/8 60,000 95 60,000 50
60VM - - - -
(9.53) (4137) (6.6) (4137) (3.5)
9/16 60,000 95 60,000 50
- - - -
(14.30) (4137) (6.6) (4137) (3.5)
Notes: Actuator Selection Guide (choose actuator based on available air pressure).
6 15SM Valves replace 10SM Valves and are rated to 15,000 psi (1035 bar).
TOC
O.D.
Pressure Rating Straight Union Bulkhead
Tube Size Elbow Tee Cross
psi (bar) Coupling Coupling Coupling
in. (mm)
1/4 (6.35) 20,000 (1380) CLX4400 CTX4440 CXX4444 20FX4466 20UFX4466 20BFX4466
3/8 (9.53) 20,000 (1380) CLX6600 CTX6660 CXX6666 20FX6666 20UFX6666 20BFX6666
Medium 9/16 (14.3) 20,000 (1380) CLX9900 CTX9990 CXX9999 20FX9966 20UFX9966 20BFX9966
Pressure 3/4 (19.1) 20,000 (1380) CLX12 CTX12 CXX12 20FX12 20UFX12 20BFX12
1 (25.4) 20,000 (1380) CLX16 CTX16 CXX16 20FX16 20UFX16 20BFX16
1-1/2 (38.1) 15,000 (1035) CLX24 CTX24 CXX24 15FX24 15UFX24 15BFX24
1 (25.4) 43,000 (2964) 43CL16 43CT16 43CX16 43F16 43UF16 43BF16
9/16 (14.3) 40,000 (2760) 40CL9900 40CT9990 40CX9999 40F9933 40UF9933 40BF9933
High 1/4 (6.35) 60,000 (4140) CL4400 CT4440 CX4444 60F4433 60UF4433 60BF4433
Pressure 3/8 (9.53) 60,000 (4140) CL6600 CT6660 CX6666 60F6633 60UF6633 60BF6633
9/16 (14.3) 60,000 (4140) CL9900 CT9990 CX9999 60F9933 60UF9933 60BF9933
Safety
Connection Components Check Valves Line Filters
Heads
O.D. Pressure
Excess Dual Cup Safety
Tube Size Rating Gland Collar Plug O-Ring Ball
Flow Disc Type Heads
in. (mm) psi (bar)
1/4 (6.35) 20,000 (1380) CGLX40 CCLX40 CPX40 CXO4400 CXB4400 CXK4402
- CXF4 CSX4600*
3/8 (9.53) 20,000 (1380) CGLX60 CCLX60 CPX60 CXO6600 CXB6600 CXK6602
- CXF6 CSX6600*
Medium 9/16 (14.3) 20,000 (1380) CGLX90 CCLX90 CPX90 CXO9900 CXB9900 CXK9902
CLFX9900 CXF9 CSX9600*
Pressure 3/4 (19.1) 20,000 (1380) CGLX120 CCLX120 CPX120 CXO12 CXB12 CXK1202
- CXF12 -
1 (25.4) 20,000 (1380) CGLX160 CCLX160 CPX160 CXO16 CXB16 CXK1602
- CXF16 -
1-1/2 (38.1) 15,000 (1035) CGLX240 CCLX240 CPX240 CXO240 CXB240 -
1 (25.4) 43,000 (2964) CGLX160 CCLX160 43CP160 43CKO16 43CB16 - - - -
9/16 (14.3) 40,000 (2760) AGL90 ACL90 AP90 - - - - - -
High 1/4 (6.35) 60,000 (4140) AGL40 ACL40 AP40 CKO4400 CB4401 CK4402 CLF4400 CF4 CS4600*
Pressure 3/8 (9.53) 60,000 (4140) AGL60 ACL60 AP60 CKO6600 CB6601 CK6602 CLF6600 CF6 CS6600*
9/16 (14.3) 60,000 (4140) AGL90 ACL90 AP90 CKO9900 CB9901 CK9902 CLF9900 CF9 CS9600*
Tubing
Parker Autoclave Engineers offer a complete selection of Austenetic, cold drawn stainless steel tubing designed to match the
performance standards of Parker Autoclave Engineers valves and fittings. PAE tubing is manufactured specifically for medium
and high pressure applications requiring both strength and corrosion resistance. The tubing is furnished in random lengths
between 20 and 26.5 feet (6.1 and 8.0 meter).
Note: For autofrettage tubing, add suffix “ESR42” to the tubing part number.
8
TOC
Special lengths
In addition to the standard lengths listed in the table below, nipples are available in any custom length. Consult factory.
Materials
Catalog numbers in table refer to Type 316 stainless steel, unless specified.
9
TOC
Catalog Number
O.D. Tubing Size
in (mm) Medium Pressure High Pressure
to 20,000 to 60,000
1/4 (6.35) KCBGLX40-316MC KCGL40-316
3/8 (9.53) KCBGLX60-316MC KCGL60-316
9/16 (14.3) KCBGLX90-316MC KCGL90-316
3/4 (19.1) KCBGLX120-316MC -
1 (25.4) KCBGLX160-316MC +KCBGLX160-316MC
Gland Nut
Slotted collet
Collet grips
tubing here for
anti-vibration Collet body
support
Valve or
fitting body
Collar*
Line contact
sealing
Series KCBGLX
Pressures to 20,000 psi (1380 bar)
Gland Nut
Slotted collet
Valve or
fitting body
Collet grips
tubing here for
anti-vibration
support
Collar*
Line contact
sealing
Series KCGL
Pressures to 60,000 psi (1440 bar)
Male/Female Adapters
Male/female adapters are designed to adapt a female connection direct to another size and/or type of connection. In selecting
an adapter involving two different sized connections, the larger connection should be on the male end where it is possible to
maximize the mechanical strength of the adapter. See valve fitting and tubing catalog for complete selection.
1/4 20,000
SF250CX 20M44K6 20M46K6 20M49K6 N/A N/A N/A 20M44K3 20M46K3 20M49K3 C/F N/A
(6.35) (1380)
PAE Medium Pressure
3/8 20,000
SF375CX 20M64K6 20M66K6 20M69K6 20M612K6 N/A N/A 20M64K3 20M66K3 20M69K3 C/F N/A
(9.53) (1380)
9/16 20,000
SF562CX 20M94K6 20M96K6 20M99K6 20M912K6 20M916K6 15M924K6 20M94K3 20M96K3 20M99K3 C/F 20M916K3
(14.3) (1380)
3/4 20,000
SF750CX N/A N/A 20M129K6 20M1212K6 20M1212K6 15M1224K6 N/A 20M126K3 20M129K3 20M129K40 20M1216K3
(19.1) (1380)
1 20,000
SF1000CX N/A N/A 20M169K6 20M1612K6 20M1616K6 15M1624K6 N/A 20M166K3 20M169K3 C/F 20M1616K3
(25.4) (1380)
1-1/2 15,000
SF15000CX N/A N/A 15M249K6 15M2412K6 15M2416K6 15M2424K6 N/A N/A C/F C/F C/F
(38.1) (1034)
1/4 60,000
F250C 20M44B6 20M46B6 20M49B6 N/A N/A N/A 60M44B3 60M46B3 60M49B3 C/F N/A
(6.35) (4140)
PAE High Pressure
3/8 60,000
F375C 20M64B6 20M66B6 20M69B6 20M612B6 N/A N/A 60M64B3 60M96B3 60M69B3 C/F N/A
(9.53) (4140)
9/16 60,000
F562C 20M94B6 20M96B6 20M99B6 20M912B6 20M916B6 N/A 60M94B3 60M96B3 60M99B3 40M99G40 43M916B3
(14.3) (4140)
9/16 40,000
F562C40 C/F C/F C/F 20M912G6 C/F N/A C/F C/F 40M99G40 40M99G40 C/F
(14.3) (2758)
1 43,000
F1000C43 N/A N/A 20M169B6 C/F C/F 15M1624B6 N/A N/A 43M169B3 43M169B40 C/F
(25.4) (2964)
*N/APressure Rating - The pressure rating of Parker Autoclave Engineers couplings is based on the lower rated connection used.
= Not Available
C/F = Consult Factory
Other Adapters
Parker Autoclave Engineers supplies many other types of adapters on special orders.
These include NPT, Buttweld, Header Coupling, QSS, EZ-Union, Male SAE-Oring, JIC connections and others.
Materials
All Parker Autoclave Engineers adapters are precision machined from cold-worked Type 316 stainless steel.
Other materials available on special order.
11
TOC
Adapter Couplings
The couplings shown here permit the joining of any combination of standard size Parker Autoclave Engineers tubing with
female-to-female couplings. Other couplings available on special order. See valve fitting and tubing catalog for complete
selection.
“B” Connection
“A” Connection
PAE Medium Pressure PAE High Pressure
Tube 1/4 3/8 9/16 3/4 1 1-1/2 1/4 3/8 9/16 9/16 1
Press.
Size Connection
psi* (6.35) (9.53) (14.3) (19.1) (25.4) (38.1) (6.35) (9.53) (14.3) (14.3) (25.4)
in Type
(bar)
(mm) SF250CX SF375CX SF562CX SF750CX SF1000CX SF15000CX F250C F375C F562C F562C40 F1000C43
1/4 20,000
SF250CX 20FX4466 20F4666 20F4966 N/A N/A N/A 20F4463 20F4663 20F4963 C/F N/A
(6.35) (1380)
PAE Medium Pressure
3/8 20,000
SF375CX 20FX6666 20F6966 20F61266 N/A N/A 20F6463 20F6663 20F6963 C/F N/A
(9.53) (1380)
9/16 20,000
SF562CX 20FX9966 20F91266 20F91666 15FX92466 20F9463 20F9663 20F9963 C/F C/F
(14.3) (1380)
3/4 20,000
SF750CX 20FX12 20F121666 C/F N/A 20F12663 20F12963 C/F C/F
(19.1) (1380)
1 20,000
SF1000CX 20FX16 15FX162466 N/A 20F16663 20F16963 C/F C/F
(25.4) (1380)
1-1/2 15,000
SF1500CX 15FX24 N/A N/A C/F C/F C/F
(38.1) (1034)
1/4 60,000
F250C 60F4433 60F4633 60F4933 C/F N/A
(6.35) (4140)
PAE High Pressure
3/8 60,000
F375C 60F6633 60F6933 C/F N/A
(9.53) (4140)
9/16 60,000
F562C 60F9933 40F9933 43F91633
(14.3) (4140)
9/16 40,000
F562C40 40F9933 C/F
(14.3) (2758)
1 43,000
F1000C43 43F16
(25.4) (2964)
12
TOC
Ball Valves
High Pressure
Parker Autoclave Engineers Ball Valves are designed for on-off, high flow, high pressure
applications and provide superior quality with maximum performance. Our unique one-piece
trunnion mounted stem/ball eliminates the shear failure common in two-piece designs.
Our re-torqueable seat glands result in longer seat life and our low friction stem seal
reduces actuation torque and enhances cycle life.
Parker Autoclave Engineers ball valves can be operated safely up to 20,000 psi and up
to 500°F with the high temperature option. 2-way, 3-way & 4-Way Switching & Cross-
over styles are available.
Order Matrix: (See main catalog for all options including o-ring materials)
2B 4 S 20 M 4 -
Maximum Rated
Valve Series Ball Orifice Material End Connection Type2 End Connection Size Options
Pressure x10001
2B = 2 Way 33 = 3/16” S = 316 SS 5 L = Low Pressure 4 = 1/4” HT = High Temp.
3B = 3 Way 4 = 1/4” for other 10 M = Medium Pressure 6 = 3/8” AO = Air to Open
options
3BD = 3 Way Diverter 6 = 3/8” 15 H = High Pressure 8 = 1/2” AC = Air to Close
contact factory
4B5 = 4 way Crossover 8 = 1/2” 20 P = NPT 9 = 9/16” AOC = Air to Open/Close
4BS5 = 4 Way Switching 124 = 3/4” 12 = 3/4” EO1 = Electric 120VAC
164 = 1” 16 = 1” EO2 = Electric 220VAC
24 = 1-1/2” EO3 = Electric 240VDC
Note: Matrix can build valves not yet available, refer to main catalog for exact size/valve series selection
1 = Pressure chosen after considering orifice size, connection and temperature requirements - see main catalog for all available operations.
2 = Low Pressure connection sizes 1/8” through 1/2”, Medium and High Pressure connections not available in 1/8” or 1/2”, NPT connections rated
to 15,000 psi up to 1/2” and 10,000 psi for 3/4” and 1”.
3 = Only available in 3-Way valve models
4 = Only available in 2-Way valve models
5 = 4B & 4BS only available in 3/8" orifice size
13
TOC
**Bourdon Tube material for 0-80,000 psi (0-5116 bar) and 0-50,000 psi (0-3447 bar) gauge is Inconel 718.
Bourdon Tube material for 0-30,000 psi (0-2068 bar) gauge is K Monel.
Note: Gauges available with back connections. Add B to the base catalog number. Ex: P-047B-CG
1/4” (F250C) Coned-and-Threaded Connection Furnished with Collar and Gland
14
TOC
Parker Autoclave Engineers will design and build pressure manifolds to meet specific
installation, layout and pressure requirements. These manifolds are capable of withstanding
pressures from vacuum to 60,000 psi (4137 bar), and are available in a variety of materials and sizes.
These manifolds are appropriate wherever pressure tubing systems are utilized.
These precision valves are designed for pressure gas systems, cryogenic systems, petrochemical
applications and other special systems. They are capable of handling air, gases, steam, vapor and
liquids. They are not recommended for steam boiler applications and are not ASME code stampable.
Relief valves are designed to open proportionally to increasing back pressure and, therefore, are not
recommended for applications requiring immediate full valve flow at set pressure. Full flow of relief
valve is defined at 10% over set pressure.
RVP & PRVP Metal Seat, RVS & PRVS Soft Seat Series Relief Valve
Connection Size and Type Orifice Pressure Rating psi (bar) @ 100ºF (38ºC)
Catalog
Inlet Outlet Diameter Minimum Maximum Maximum
Number*
Connection Connection Inches (mm) Setting Setting Back Pressure
5PRVP8072 1/2" FNPT 3/4 FNPT 0.312 (7.92) 3,000 (210) 5,000 (345) 500 (35)
10PRVP8072 1/2" FNPT 3/4 FNPT 0.250 (6.35) 5,000 (345) 10,000 (690) 500 (35)
15PRVP8072 1/2" FNPT 3/4 FNPT 0.188 (4.78) 10,000 (690) 15,000 (1035) 500 (35)
5RVP9072 SF562CX (9/16" MP) 3/4 FNPT 0.312 (7.92) 3,000 (210) 5,000 (345) 500 (35)
10RVP9072 SF562CX (9/16" MP) 3/4 FNPT 0.250 (6.35) 5,000 (345) 10,000 (690) 500 (35)
15RVP9072 SF562CX (9/16" MP) 3/4 FNPT 0.188 (4.78) 10,000 (690) 15,000 (1035) 500 (35)
20RVP9072 SF562CX (9/16" MP) 3/4 FNPT 0.156 (3.96) 15,000 (1035) 20,000 (1380) 500 (35)
30RVP6072 F375C (3/8" HP) 3/4 FNPT 0.125 (3.18) 15,000 (1035) 30,000 (2070) 500 (35)
45RVP9072 F562C (9/16" HP) 3/4 FNPT 0.093 (2.36) 25,000 (1725) 45,000 (3100) 500 (35)
60RVP6072 F375C (3/8" HP) 3/4 FNPT 0.078 (1.98) 30,000 (2070) 60,000 (4140) 500 (35)
75RVP5072 F312C150 (5/16" UHP) 3/4 FNPT 0.062 (1.57) 37,000 (2550) 75,000 (5170) 500 (35)
5PRVS8072 1/2" FNPT 3/4 FNPT 0.312 (7.92) 1,500 (103) 5,000 (345) 500 (35)
10PRVS8072 1/2" FNPT 3/4 FNPT 0.250 (6.35) 5,000 (345) 10,000 (690) 500 (35)
15PRVS8072 1/2" FNPT 3/4 FNPT 0.188 (4.78) 10,000 (690) 15,000 (1035) 500 (35)
5RVS9072 SF562CX (9/16" MP) 3/4 FNPT 0.312 (7.92) 1,500 (105) 5,000 (345) 500 (35)
10RVS9072 SF562CX (9/16" MP) 3/4 FNPT 0.250 (6.35) 5,000 (345) 10,000 (690) 500 (35)
20RVS9072 SF562CX (9/16" MP) 3/4 FNPT 0.156 (3.96) 10,000 (690) 20,000 (1378) 500 (35)
* Maximum pressure rating based on the lowest rating of any component. Actual working pressure may be determined by tubing pressure rating, if lower.
15
Note: For pressure rating see selection chart. 1 Include suffix from original valve for correct options
TOC
Tools
Manual Coning and Threading Tools
Parker Autoclave Engineers manufactures a manual coning tool for optimum coning
performance with tubing sizes up to 9/16” (14.3 mm) O.D. This is a precision
quality manual tool to permit on-site end preparation for AE medium and high
pressure tubing installations. Interchangeable collets for each size tubing provide
proper centering of tubing. The cutting feed arrangement permits the operator to
control the depth of cut to assure against work hardening effects. Interchangeable
tool steel cutting blades are used in pairs to assure more accurate and faster con-
ing and are designed to square-off and finish the tube as the cone is completed.
There is a provision for applying metal cutting lubricants to the cutting zone.
The threading die holder is designed to hold the appropriate die for any of the
standard Parker Autoclave Engineers tubing sizes through 9/16” (14.3 mm) O.D. Complete Coning & Threading Kits
Interchangeable guide bushings properly guide the tool for accurate thread cutting. Medium Pressure, 1/4" to 9/16" = KMCT-MT
High Pressure, 1/4" to 9/16" = KMCT-HT
Note: Complete tool kits are available. Consult factory
Feed Nut
Coning Tool
Housing
Oil/Chip Reservoir*
Vice Arm*
Threading Tool
* For coning tool with optional Vice Arm and Oil/Chip Reservoir, add RS suffix to model number. Ex: MCTM4-RS
Tube Size Coning Tools and Components Catalog Number Threading Tools and Components Catalog Number
O.D. I.D. Tool with Coning Blades Tool with Tool Threading Die
Collet Guide Bushing
in (mm) in (mm) Collet & Blades (Set of 2) Die & Bushing Only Order No. Size-type*
PAE Medium Pressure
1/4 (6.35) .109 (2.77) MCTM4 90248 CT4BX 402A 402 P-0214 1/4-28 1010-0343
3/8 (9.53) .203 (5.16) MCTM6 90250 CT6BX 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .312 (7.92) MCTM920 90251 CT9BX 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .359 (9.12) MCTM910 90251 CT9BXX 402E 402 P-0216 9/16-18 1010-0345
1/4 (6.35) .083 (2.11) MCTH4 90248 CT4B 402A 402 P-0214 1/4-28 1010-0343
PAE High Pressure
3/8 (9.53) .125 (3.18) MCTH6 90250 CT6B 402C 402 P-0215 3/8-24 1010-0344
9/16 (14.3) .188 (4.78) MCTH960 90251 CT9B 402E 402 P-0216 9/16-18 1010-0345
9/16 (14.3) .250 (6.35) MCTh940 90251 CT9B40 402E 402 P-0216 9/16-18 1010-0345
16
TOC
Tools
PAE Micrometer Adjustable Torque Wrench
P-1680 20 to 150 ft. lbs. (27 to 203 Nm)
91020 75 to 250 ft. lbs. (102 to 339 Nm)
Accurate tightening for all Parker Autoclave Engineers valve packing
glands and tube nuts is essential. The wrench can be adjusted to the
ranges shown and is used with interchangeable wrench adapters for hex sizes
from 1/2” through 1-7/8”. Part numbers for wrench adapters are listed on chart.
Packing Gland or
1/2 9/16 5/8 3/4 13/16 7/8 15/16 1 1-1/16 1-3/16 1-3/8 1-1/2 1-7/8
Gland Nut Hex Size
(12.7) (14.3) (15.9) (19.05) (20.6) (22.2) (23.8) (25.4) (27) (30.2) (34.9) (38.1) (47.6)
in (mm)
Wrench Adapter
P-1681 P-1682 P-1683 P-9813 P-1685 P-1686 P-1687 P-9901 P-1688 P-1689 P-1690 P-6040 P-10076
Number
* For
For Gland Nut size for each connection, see Gland Torque chart in Tools & Installation catalog.
Packing Gland sizes, see Packing Gland Torque chart in same.
Separate heads for coning and threading are powered by a single motor and drive system.
Available models cone and thread Parker Autoclave Engineers medium and high pressure tubing.
Approximate dimensions: 56” high, 28” wide and 20” deep (1.4 m x .7 m x .5 m).
Shipping weight is 350 pounds (159 kg). Tooling ordered separately. Consult factory.
Features
• One-half hp motor, 115 VAC 60 Hz (220 VAC 50 Hz) volt capacitor start.
• No reversing necessary on threading operation; pop-open die prevents thread damage.
• Complete tooling is available; specify tooling sizes required.
• Coning head has feed wheel for easy, precision feeding.
• Complete with oil pump and reservoir.
• Unit mounted on stand complete with locking casters for ease of mobility and stability.
• Available with optional reservoir heater
• CE mark standard on 220 VAC 50 Hz models
17
TOC
Connections
Parker Autoclave Medium Pressure SF** (SM Series Valves)
20,000 psi Maximum Pressure
SF750CX10* 61/64 3/4 -14 .50 .94 .63 .516 (13.1) Weep
3/4 hole
SF750CX20 (24.2) see Note 1 (12.7) (23.9) (16.0) .438 (11.1) H
Parker Autoclave High Pressure F** (30, 43 SC and 30, 40, 60VM Valves)
60,000 psi Maximum Pressure
Note: All dimensions are shown for reference only and should not be considered as actual machining dimensions.
For port Diameter please see orifice sizes for specific valves and fittings. All threads are manufactured to a class 2A or 2B fit.
18
TOC
Flow Calculations
Coefficient of flow (CV) for a valve is the volume of water in U.S. gallons per minute at room temperature...which will flow
through the valve with the stem fully open...with a pressure drop of 1 psi across the valve. CV is the valve sizing factor that
permits selection of the appropriate valve to meet the flow requirements of a given fluid system.
The CV values shown on the valve ordering pages represent the full-open CV for that valve. In determining estimated capacity,
this CV value should be used in the formulas which follow.
Flow Formulas
Liquids V = CV √ P1 - P2
√SGF
• Flow, U.S. gal./min.
• Flow, lb./hr.
W = 500 CV √ (P1 - P2) /SGF
Gases **
Q = 42.2 CV √ (P1 - P2) (P1 + P2)
• Flow, SCFH √ SGF
• Flow, SCFH (temperature corrected)
• Flow, lb./hr. *
Q = 963 CV √ (P1 - P2) (P1 + P2)
√ SGF TF
Saturated Steam
*
• Flow, lb./hr. W = 3.22 CV √ (P1 - P2) (P1 + P2)/SG
*
Super Heated Steam W = 2.1 CV √ (P1 - P2) (P1 + P2)
(1 + 0.0007 TS)
Note: Maximum CV values in this catalog have been determined in accordance with the Fluid Controls Institute report
FCI 58-2. “Recommended Voluntary Standards for Measurement Procedure for Determining Control Valve Flow
Capacity,” including procedure, design of the test stand and evaluation of the data.
19
TOC
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE
DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users
having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to
the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the
products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed
by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
© 2022 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0115BE April 2022