WEB VERSION

Parker Autoclave Medium and High Pressure


Cone & Thread Product Condensed Catalog
Valves, Fittings, Tubing
20,000 psi and 60,000 psi Service April, 2022

Instrumentation Products Division


Section Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Manual Needle Valves . . . . . . . . . . . . . . . . . . . . . . . . . 3
Air Actuators (for P-AE Needle Valves) . . . . . . . . . . . . . . . . . 4
Fittings, Components & Accessories . . . . . . . . . . . . . . . . . . 7
Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Coned and Threaded Nipples . . . . . . . . . . . . . . . . . . . . . . 9
Anti-Vibration Collet Gland Assemblies . . . . . . . . . . . . . . . . 10
Male/Female Adapters . . . . . . . . . . . . . . . . . . . . . . . . . 11
Adapter Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Instrument Quality Gauges . . . . . . . . . . . . . . . . . . . . . . 14
Manifolds and Relief Valves . . . . . . . . . . . . . . . . . . . . . . 15
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Flow Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Sour Service Products . . . . . . . . . . . . . . . . . . . . . . . . . 20

The world leader in high pressure valves, fittings and tubing


Since its inception in 1945, Parker Autoclave Engineers (PAE) install connection in all sizes up to 15,000 psi (1034 bar).
has been dedicated to manufacturing high pressure and For more information, or to order a complete catalog, con-
extreme temperature valve, fitting, and instrument tubing tact your nearest Parker Autoclave Engineers representative.
systems which are coordinated together to operate safely
and reliably. Today, Parker Autoclave Engineers is a world Flared Cone Connection (FCC) (0-22,500 psi)
leader combining our high pressure knowledge, manufactur- Our latest innovation is the Flared Cone Connection that
ing expertise, and technological innovation to offer a broad merges a single ferrule, bite-type compression design with
range of products and services to our customers, across a flared tubing that prevents any tube extraction while offer-
wide range of industries. ing two redundant sealing surfaces. This two-step hydrauli-
cally set system saves installation time over typical Cone
Low Pressure (0-15,000 psi) Valves, Fittings and & Thread Connections. Available in both 316 SS and 2507
Tubing Super Duplex tubing, fittings, and valves.
While Parker Autoclave Engineers products are known
industry wide for their ability to operate at pressures in Needle Valves
excess of 150,000 psi (10,340 bar), a Low Pressure line All Parker Autoclave Engineers Needle Valves incorporate
nicknamed “Speedbite”, rated for applications to 15,000 psi a rising stem/block design while the non-rotating feature
(1034 bar) is available, but not discussed in this brochure. of the stem prevents galling. In addition, the valves are
Speedbite valves and fittings utilize a single ferrule com- designed with metal to metal seating for bubble tight shut-
pression sleeve connection which provides easy, leak free off, long stem/seat life even in abrasive flow conditions, and
performance, matched to PAE specified instrument tubing excellent overall corrosion resistance.
sizes from 1/16” to ½”.
Parker Autoclave Engineers components are offered in
Quick Set System (QSS) (0-15,000 psi) 316SS as standard, but can be ordered in a variety of
optional materials such as: Super Duplex, 6Mo, Hastelloy*
To enhance the Speedbite product line, Parker Autoclave B & C, Inconel, Monel or any one of our 40 other supported
Engineers has engineered (not shown in this catalog) an materials.
advanced single ferrule fitting system called the QSS-Quick
Set System. Designed to work with our Medium Pressure For more information see our website at www.Autoclave.
316 cold worked S.S. , 2507 Super Duplex™, and Inconel com. To order a complete VFT Catalog, contact your nearest
625 instrument tubing, this 1/4” through 1” O.D. connection Parker Autoclave Engineers representative or the company
is utilized in our valves and fittings to provide a simple to direct at 814-860-5700.

* Hastelloy is a trademark of Haynes International Inc.


2
TOC

Manual Needle Valves


Parker Autoclave Engineers valves are designed to operate safely and reliably at pressures to 150,000 psi (10342 bar).
Several important features make this dependable service possible under widely varying conditions.

Stem: can be readjusted to minimize


Handles: Non-rotating stem
powder coated stainless steel. Prevents stem/seat galling when valve is opened
backlash while valve is in service.
and closed.
Packing gland: nickel-plated Postive Locking
aluminum-bronze minimizes stem Device: Metal-to-Metal seating
operating torque. prevents inadvertent unthread-
Provides bubble-tight shut-off, longer stem/seat life
ing of bonnet. in abrasive flow, greater durability for repeated on/off
Stainless steel bearing washer: cycles and excellent corrosion resistance.
silver-plated to minimize stem Panel mounting
friction. screw holes: PTFE packing
standard on every valve.
Bracket mounting holes: Ensures dependable stem and body sealing. The stem
standard on every valve. sleeve and packing gland materials extend thread life and
Packing below stem reduce the handle torque required to operate the valve.
Cold Worked Bodies: permit high threads: adjustable; separates
pressures in a smaller block size, and threads and thread lubricants Manual valve options
also extend valve service life. from process fluid. Five different body patterns, a variety of materials and
Non-Rotating one piece stems: stem types, extreme temperature models, abrasive ser-
vice options, panel mounting and several handle styles
prevent galling and scoring of stem are among the available options.
and seat; provide repeatable bubble-
tight shut-off.

Vee and Regulating Stem


End Connections: tips available.
coned-and-threaded with optional
anti-vibration collet gland assemblies. Model 20SM9071 shown.

O.D. *Rated
Pressure
Tube Cv Valve
Rating
Size (full Stem
psi (bar)
In (mm) open) Type

2 Way 2 Way 3 Way 3 Way 2 Way Angle 3 Way


Straight Angle 2 on Pressure 1 on Pressure Replaceable Seat 2 Stem Manifold
1/4 20,000 Vee 20SM4071 20SM4072 20SM4073 20SM4074 20SM4872 20SM4075
.31
(6.35) (1380) Reg 20SM4081 20SM4082 20SM4083 20SM4084 20SM4882 20SM4085
3/8 20,000 Vee 20SM6071 20SM6072 20SM6073 20SM6074 20SM6872 20SV6075
.75
(9.53) (1380) Reg 20SM6081 20SM6082 20SM6083 20SM6084 20SM6882 20SM6085
9/16 20,000 Vee 20SM9071 20SM9072 20SM9073 20SM9074 20SM9872 20SM9075
1.30
(14.30) (1380) Reg 20SM9081 20SM9082 20SM9083 20SM9084 20SM9882 20SM9085
3/4 20,000 2.50 Vee 20SM12071 20SM12072 20SM12073 20SM12074 20SM12872 20SM12075
Medium (19.10) (1380) Reg 20SM12081 20SM12082 20SM12083 20SM12084 20SM12882 20SM12085
Pressure 1 20,000 Vee 20SM16071 20SM16072 20SM16073 20SM16074 20SM16872 20SM16075
4.40
(25.40) (1380) Reg 20SM16081 20SM16082 20SM16083 20SM16084 20SM16882 20SM16085
9/16 10,000 Vee 15SM9071 15SM9072 15SM9073 15SM9074 15SM9872 15SM9075
1.75
(14.30) (690) Reg 15SM9081 15SM9082 15SM9083 15SM9084 15SM9882 15SM9085
3/4 10,000 Vee 15SM12071 15SM12072 15SM12073 15SM12074 15SM12872 15SM12075
2.80
(19.10) (690) Reg 15SM12081 15SM12082 15SM12083 15SM12084 15SM12882 15SM12085
1 10,000 Vee 15SM16071 15SM16072 15SM16073 15SM16074 15SM16872 15SM16075
5.20
(25.40) (690) Reg 15SM16081 15SM16082 15SM16083 15SM16084 15SM16882 15SM16085
1 30,000 Vee 30SC16071 30SC16072 30SC16073 30SC16074 30SC16872 30SC16075
2.60
(25.40) (2070) Reg 30SC16081 30SC16082 30SC16083 30SC16084 30SC16882 30SC16085
1/4 30,000 Vee 30VM4071 30VM4072 30VM4073 30VM4074 30VM4872 30VM4075
.12
(6.35) (2070) Reg 30VM4081 30VM4082 30VM4083 30VM4084 30VM4882 30VM4085
3/8 30,000 Vee 30VM6071 30VM6072 30VM6073 30VM6074 30VM6872 30VM6075
.23
(9.53) (2070) Reg 30VM6081 30VM6082 30VM6083 30VM6084 30VM6882 30VM6085
9/16 30,000 Vee 30VM9071 30VM9072 30VM9073 30VM9074 30VM9872 30VM9075
.33
High (14.30) (2070) Reg 30VM9081 30VM9082 30VM9083 30VM9084 30VM9882 30VM9085
Pressure 9/16 40,000 Vee 40VM9071 40VM9072 40VM9073 40VM9074 40VM9872 40VM9075
.28
(14.30) (2760) Reg 40VM9081 40VM9082 40VM9083 40VM9084 40VM9882 40VM9085
1/4 60,000 Vee 60VM4071 60VM4072 60VM4073 60VM4074 60VM4872 60VM4075
.08
(6.35) (4140) Reg 60VM4081 60VM4082 60VM4083 60VM4084 60VM4882 60VM4085
3/8 60,000 Vee 60VM6071 60VM6072 60VM6073 60VM6074 60VM6872 60VM6075
.09
(9.53) (4140) Reg 60VM6081 60VM6082 60VM6083 60VM6084 60VM6882 60VM6085
9/16 60,000 Vee 60VM9071 60VM9072 60VM9073 60VM9074 60VM9872 60VM9075
.14
(14.30) (4140) Reg 60VM9081 60VM9082 60VM9083 60VM9084 60VM9882 60VM9085
3
* C Valves shown are for 2-way straight pattern. For 2-way angle, increase C Valve 50%. Note: SM Series replaces 20SC Series
V V
TOC

Air Actuators (for PAE Needle Valves)


Three sizes of air operators (medium, heavy duty or extra heavy) are offered for remote on-off operation or automatic
operation of Parker Autoclave Engineers medium or high pressure valves. The actuators are available in air-to-open (normally
closed) and air-to-close (normally open) designs.

Ordering Procedure (Consult factory to insure proper selection)


To order a valve with an air operator, select the duty rating and type of the air operator from the chart on page 5 & 6. Add the
air operator identifying suffix to the catalog number of the Parker Autoclave Engineers valve. To order a 2-way straight, 30VM
vee stem, 9/16” (14.3 mm) valve with a medium duty air-to-close piston air operator, specify: ex: 30VM9071-C1S.

Duty Rating Operator Type Order Suffix

Air to Open O1S


Medium Piston
Air to Close C1S
Air to Open O2S
Heavy Piston
Air to Close C2S
Extra Heavy Air to Open HO1S
Piston
Single Stage Air to Close HC1S
Extra Heavy Air to Open HO2S
Piston
Two Stage Air to Close HC2S

60VM9071-O2S
Air To Open
Piston Activated
Note: For outdoor service actuators, please see main catalog.

4
TOC

Air Actuators (for PAE Needle Valves)


This table is designed to allow quick selection of an appropriate piston air actuator based on
valve style and size, maximum system operating pressure and maximum available air pressure.

For example, a 9/16” 20SM valve can operate to 10,700 psi with 100 psi air pressure using the
Medium Piston (-C1S) or 20,000 psi MAWP with the Heavy (-C2S) actuator. or can operate to
20,000 psi using only 65 psi air pressure with the Extra Heavy Duty Single Stage Piston (-HC1S).

Note: See main catalog for complete sizing information.

10V6071-C1S
Air To Close
Piston Activated

Air to Close: Actuator Selection Guide

Medium (-C1S) Heavy (-C2S) Extra Heavy Single Stage (-HC1S) Extra Heavy Two Stage (-HC2S)
O.D.
Valve Series Tube System Air System Air System Air System Air
in. (mm) Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure
psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
9/16 8,600 100 15,000 75 15,000 60 15,000 35
(14.30) (593) (6.9) (1035) (5.2) (1035) (4.2) (1035) (2.4)
3/4 15,000 100 15,000 100 15,000 50
- -
(19.10) (1035) (6.9) (1035) (69) (1035) (3.5)
15SM
1 6,300 100 8,500 95 10,000 55
- -
(25.40) (434) (6.9) (586) (6.55) (690) (3.79)
1.5 10,000 90
- - - - - -
(38) (690) (8)
1/4 20,000 95 20,000 50
- - - -
(6.35) (1380) (6.5) (1380) (3.5)
3/8 19,000 100 20,000 55
- - - -
(9.53) (1310) (6.9) (1380) (3.8)
9/16 10,700 100 20,000 85 20,000 65
20SM - -
(14.30) (734) (6.9) (1380) (5.9) (1380) (4.48)
3/4 6,100 100 13,600 100 19,000 100 20,000 50
(19.10) (421) (6.9) (938) (6.9) (1310) (6.90) (1380) (3.4)
1 8,800 100 12,500 100 20,000 75
- -
(25.40) (607) (6.9) (862) (6.90) (1380) (5.1)
1 30,000 80
30SC - - - - - -
(25.40) (2068) (5.5)
1/4 30,000 55 30,000 30
- - - -
(6.35) (2068) (3.8) (2068) (2.0)
3/8 30,000 75 30,000 40
30VM - - - -
(9.53) (2068) (5.2) (2068) (2.8)
9/16 30,000 75 30,000 40
- - - -
(14.30) (2068) (5.2) (2068) (2.8)
9/16 40,000 90 40,000 45
40VM - - - -
(14.30) (2758) (6.2) (2758) (3.1)
1/4 60,000 75 60,000 40
- - - -
(6.35) (4137) (5.2) (4137) (2.8)
3/8 60,000 75 60,000 40
60VM - - - -
(9.53) (4137) (5.2) (4137) (2.8)
9/16 60,000 90 60,000 45
- - - -
(14.30) (4137) (6.2) (4137) (3.1)
Notes: Actuator Selection Guide (choose actuator based on available air pressure).
5
15SM Valves replace 10SM Valves and are rated to 15,000 psi (1035 bar).
TOC

Air Actuators (for PAE Needle Valves)


This table is designed to allow quick selection of an appropriate piston air actuator based on valve
style and size, maximum system operating pressure and maximum available air pressure.

For example, a 9/16" 20SM valve can operate to 9,800 psi with 100 psi air pressure using the
Medium Piston (-O1S) or 15,700 psi MAWP with the Heavy (-O2S) actuator. or can operate to
20,000 psi using only 85 psi air pressure with the Extra Heavy Duty Single Stage Piston (-HO1S).

Note: See main catalog for complete sizing information.

20SM6872-O1S
Air To Open
Piston Activated
Air to Open: Actuator Selection Guide

Medium (-O1S) Heavy (-O2S) Extra Heavy Single Stage (-HO1S) Extra Heavy Two Stage (-HO2S)
O.D.
Valve Series Tube System Air System Air System Air System Air
in. (mm) Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure
psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar) psi (bar)
9/16 12,000 80 15,000 80 15,000 55
- -
(14) (830) (5.5) (1035) (5.5) (1035) (4)
3/4 12,000 100 15,000 75
- - - -
(19) (830) (7) (1035) (5)
15SM
1 6,500 100 10,000 85
- - - -
(25) (448) (7) (690) (5.9)
1.5 9,000 100
- - - - - -
(38) (621) (7)
1/4 20,000 95 20,000 50
- - - -
(6.35) (1380) (6.6) (1380) (3.4)
3/8 18,250 95 18,250 50
- - - -
(9.53) (1258) (6.6) (1258) (3.4)
9/16 9,800 95 15,700 75 20,000 85 20,000 55
20SM
(14.30) (676) (6.6) (1082) (5.1) (1380) (5.86) (1380) (3.8)
3/4 6,000 75 15,000 100 20,000 80
- -
(19.10) (414) (5.1) (1034) (7) (1380) (5.5)
1 10,000 100 20,000 100
- - - -
(25.40) (690) (7) (1380) (7)
1 30,000 100
30SC - - - - - -
(25.40) (2068) (7)
1/4 30,000 75 30,000 40
- - - -
(6.35) (2068) (5.2) (2068) (2.8)
3/8 30,000 95 30,000 50
30VM - - - -
(9.53) (2068) (6.6) (2068) (3.5)
9/16 30,000 95 30,000 50
- - - -
(14.30) (2068) (6.6) (2068) (3.5)
9/16 40,000 100 40,000 55
40VM - - - -
(14.30) (2758) (6.9) (2758) (3.8)
1/4 60,000 95 60,000 50
- - - -
(6.35) (4137) (6.6) (4137) (3.5)
3/8 60,000 95 60,000 50
60VM - - - -
(9.53) (4137) (6.6) (4137) (3.5)
9/16 60,000 95 60,000 50
- - - -
(14.30) (4137) (6.6) (4137) (3.5)
Notes: Actuator Selection Guide (choose actuator based on available air pressure).
6 15SM Valves replace 10SM Valves and are rated to 15,000 psi (1035 bar).
TOC

Fittings, Components & Accessories


Connection Sizes Pressure Rating
Connection Type
in. (mm) psi (bar)
Coned-and-threaded type for high strength and
Medium 1/4 to 1-1/2 to 20,000 repeated make-up. Anti-Vibration collet gland
Pressure (6.4 to 38) (1380) available in line collar and gland to minimize
block thickness

Coned-and-threaded type for high strength and


1 to 43,000
repeated make-up. Anti-vibration collet gland
(25) (2964)
available.
High
Pressure Coned-and-threaded type for high strength and
1/4 to 9/16 to 60,000 repeated make-up. Anti-vibration collet gland
(6.35 to 14.3) (4140) available. Nested collar and gland to minimize
block width.

O.D.
Pressure Rating Straight Union Bulkhead
Tube Size Elbow Tee Cross
psi (bar) Coupling Coupling Coupling
in. (mm)
1/4 (6.35) 20,000 (1380) CLX4400 CTX4440 CXX4444 20FX4466 20UFX4466 20BFX4466
3/8 (9.53) 20,000 (1380) CLX6600 CTX6660 CXX6666 20FX6666 20UFX6666 20BFX6666
Medium 9/16 (14.3) 20,000 (1380) CLX9900 CTX9990 CXX9999 20FX9966 20UFX9966 20BFX9966
Pressure 3/4 (19.1) 20,000 (1380) CLX12 CTX12 CXX12 20FX12 20UFX12 20BFX12
1 (25.4) 20,000 (1380) CLX16 CTX16 CXX16 20FX16 20UFX16 20BFX16
1-1/2 (38.1) 15,000 (1035) CLX24 CTX24 CXX24 15FX24 15UFX24 15BFX24
1 (25.4) 43,000 (2964) 43CL16 43CT16 43CX16 43F16 43UF16 43BF16
9/16 (14.3) 40,000 (2760) 40CL9900 40CT9990 40CX9999 40F9933 40UF9933 40BF9933
High 1/4 (6.35) 60,000 (4140) CL4400 CT4440 CX4444 60F4433 60UF4433 60BF4433
Pressure 3/8 (9.53) 60,000 (4140) CL6600 CT6660 CX6666 60F6633 60UF6633 60BF6633
9/16 (14.3) 60,000 (4140) CL9900 CT9990 CX9999 60F9933 60UF9933 60BF9933

Safety
Connection Components Check Valves Line Filters
Heads

O.D. Pressure
Excess Dual Cup Safety
Tube Size Rating Gland Collar Plug O-Ring Ball
Flow Disc Type Heads
in. (mm) psi (bar)
1/4 (6.35) 20,000 (1380) CGLX40 CCLX40 CPX40 CXO4400 CXB4400 CXK4402
- CXF4 CSX4600*
3/8 (9.53) 20,000 (1380) CGLX60 CCLX60 CPX60 CXO6600 CXB6600 CXK6602
- CXF6 CSX6600*
Medium 9/16 (14.3) 20,000 (1380) CGLX90 CCLX90 CPX90 CXO9900 CXB9900 CXK9902
CLFX9900 CXF9 CSX9600*
Pressure 3/4 (19.1) 20,000 (1380) CGLX120 CCLX120 CPX120 CXO12 CXB12 CXK1202
- CXF12 -
1 (25.4) 20,000 (1380) CGLX160 CCLX160 CPX160 CXO16 CXB16 CXK1602
- CXF16 -
1-1/2 (38.1) 15,000 (1035) CGLX240 CCLX240 CPX240 CXO240 CXB240 -
1 (25.4) 43,000 (2964) CGLX160 CCLX160 43CP160 43CKO16 43CB16 - - - -
9/16 (14.3) 40,000 (2760) AGL90 ACL90 AP90 - - - - - -
High 1/4 (6.35) 60,000 (4140) AGL40 ACL40 AP40 CKO4400 CB4401 CK4402 CLF4400 CF4 CS4600*
Pressure 3/8 (9.53) 60,000 (4140) AGL60 ACL60 AP60 CKO6600 CB6601 CK6602 CLF6600 CF6 CS6600*
9/16 (14.3) 60,000 (4140) AGL90 ACL90 AP90 CKO9900 CB9901 CK9902 CLF9900 CF9 CS9600*

* Note: See main catalog for complete model number.


7
TOC

Tubing
Parker Autoclave Engineers offer a complete selection of Austenetic, cold drawn stainless steel tubing designed to match the
performance standards of Parker Autoclave Engineers valves and fittings. PAE tubing is manufactured specifically for medium
and high pressure applications requiring both strength and corrosion resistance. The tubing is furnished in random lengths
between 20 and 26.5 feet (6.1 and 8.0 meter).

Inspection and Testing


Parker Autoclave Engineers tubing is inspected to assure it will be free of seams, laps, fissures or other flaws, as well as
carburization or intergranular carbide precipitation. The outside and inside diameters of the tubing are subject to special
inspection and are controlled within close tolerances to assure proper fit. Sample pieces of tube for each lot are tested to
confirm mechanical properties. Hydrostatic testing is also performed on a statistical basis and is conducted at the working
pressure of the tube. Parker Autoclave Engineers will perform 100% hydrostatic testing or autofrettage for high cyclic
applications at an additional cost if desired.

Tube Size in (mm) Wall Working Pressure psi (bar)


Fits Flow
Catalog Tube Thickness
Connection O.D. I.D. Area -325 to 100ºF 200ºF 400ºF 600ºF 800ºF
Number Material Nom.
Type in (mm) in (mm) in (mm 2)
2
(-198 to 38ºC) (93ºC) (204ºC) (316ºC) (427ºC)
in (mm)
1/4 .109 .070 .009 20,000 20,000 19,250 18,050 16,800
MS15-092 316SS SF250CX
(6.35) (2.77) (1.78) (5.81) (1380) (1380) (1330) (1250) (1160)
3/8 .203 .086 .032 20,000 20,000 19,250 18,050 16,800
MS15-093 316SS SF375CX
(9.53) (5.16) (2.18) (20.6) (1380) (1380) (1330) (1250) (1160)
9/16 .312 .125 .076 20,000 20,000 19,250 18,050 16,800
MS15-085 316SS SF562CX
(14.3) (7.92) (3.17) (49) (1380) (1380) (1330) (1250) (1160)
9/16 .359 .101 .101 15,000 15,000 14,400 13,650 12,670
MS15-097 316SS SF562CX
(14.3) (9.12) (2.56) (65.2) (1034) (1034) (992) (941) (874)
.438 .156 .151 20,000 20,000 19,250 18,050 16,800
MS15-095 316SS
3/4 (11.1) (3.96) (97.4) (1380) (1380) (1330) (1250) (1160)
SF750CX
(19.1) .516 .117 .209 15,000 15,000 14,400 13,650 12,670
MS15-098 316SS
(13.1) (2.97) (135) (1034) (1034) (993) (941) (874)
.562 .219 .248 20,000 20,000 19,250 18,050 12,670
MS15-096 316SS
1 (14.3) (5.56) (160) (1380) (1380) (1330) (1250) (874)
SF1000CX
(25.4) .688 .156 .371 15,000 15,000 14,400 13,650 12,670
MS15-099 316SS
(17.5) (4.02) (239) (1034) (1034) (993) (941) (874)
1-1/2 .937 .281 .589 15,000 15,000 14,430 13,530 12,600
13041 316SS SF1500CX
(38.1) (23.8) (7.14) (444.8) (1034) (1034) (995) (932) (868)
60,000 60,000 57,750 54,250 50,700
MS15-081 316SS
1/4 .083 .083 .005 (4140) (4140) (3980) (3740) (3490)
F250C
(6.35) (2.11) (2.11) (3.22) 60,000 56,800 51,650 50,700 48,450
MS15-182 304SS
(4140) (3910) (3560) (3500) (3340)
60,000 60,000 57,750 54,250 50,700
MS15-087 316SS
3/8 .125 .125 .012 (4140) (4140) (3980) (3740) (3490)
F375C
(9.53) (3.18) (3.18) (7.74) 60,000 56,800 51,650 50,700 48,450
MS15-183 304SS
(4140) (3910) (3560) (3500) (3340)
9/16 .25 .156 .048 40,000 40,000 38,500 36,100 33,800
MS15-090 316SS F562C40
(14.3) (6.35) (4.02) (31) (2760) (2760) (2655) (2489) (2330)
60,000 60,000 57,750 54,250 50,700
MS15-083 316SS
9/16 .187 .187 .028 (4140) (4140) (3980) (3740) (3490)
F562C
(14.3) (4.78) (4.78) (18) 60,000 56,800 51,650 50,700 48,450
MS15-185 304SS
(4140) (3910) (3560) (3500) (3340)
1 .438 .281 .151 43,000 43,000 43,000 41,380 36,330
MS15-211 316SS -
(25.4) (11.1) (7.14) (97.4) (2964) (2964) (2964) (2853) (2504)

Note: For autofrettage tubing, add suffix “ESR42” to the tubing part number.

8
TOC

Coned and Threaded Nipples


For rapid system make-up, Parker Autoclave Engineers supplies pre-cut, coned-and-threaded nipples in various sizes and
lengths for Parker Autoclave Engineers valves and fittings.

Special lengths
In addition to the standard lengths listed in the table below, nipples are available in any custom length. Consult factory.

Materials
Catalog numbers in table refer to Type 316 stainless steel, unless specified.

Working Fits Tube Size in (mm) Pressure at Catalog Number


Connection 100ºF (38ºC) 2.75” 3” 4” 6” 8” 10” 12”
Type O.D. I.D. psi (bar) Length Length Length Length Length Length Length
1/4 .109 20,000
SF250CX
(6.35) (2.77) (1380)
CNX4402 CNX4403 CNX4404 CNX4406 CNX4408 CNX44010 CNX44012
3/8 .203 20,000
SF375CX
(9.53) (5.16) (1380)
CNX6603 CNX6604 CNX6606 CNX6608 CNX66010 CNX66012
9/16 .312 20,000
SF562CX
(14.3) (7.92) (1380)
CNX9904 CNX9906 CNX9908 CNX99010 CNX99012
9/16 .359 15,000
SF562CX
(14.3) (9.12) (1034)
CNLX9904 CNLX9906 CNLX9908 CNLX99010 CNLX99012
3/4 .438 20,000
SF750CX
(19.1) (11.1) (1380)
CNX1204 CNX1206 CNX1208 CNX12010 CNX12012
3/4 .515 15,000
SF750CX
(19.1) (13.1) (1034)
CNLX1204 CNLX1206 CNLX1208 CNLX12010 CNLX12012
1 .562 20,000
SF1000CX
(25.4) (14.3) (1380)
CNX1606 CNX1608 CNX16010 CNX16012
1 .688 15,000
SF1000CX
(25.4) (17.5) (1034)
CNLX1606 CNLX1608 CNLX16010 CNLX16012
1-1/2 .937 15,000
SF1500CX
(38.1) (23.79) (1034)
CNLX2406 * CNLX2408 * CNLX24010 * CNLX24012 *
1/4 .083 60,000
F250C
(6.35) (2.11) (4140)
CN4402 CN4403 CN4404 CN4406 CN4408 CN44010 CN44012
3/8 .125 60,000
F375C
(9.53) (3.18) (4140)
CN6603 CN6604 CN6606 CN6608 CN66010 CN66012
9/16 .187 60,000
F562C
(14.3) (4.78) (4140)
CN9904 CN9906 CN9908 CN99010 CN99012
9/16 .250 40,000
F562C40
(14.3) (6.35) (2760)
40CN9904 * 40CN9906 * 40CN9908 * 40CN99010 * 40CN99012 *
1 .438 43,000
F1000C43
(25.4) (11.1) (2964)
43CN1606 43CN1608 43CN16010 43CN16012

Note: * only available in 316 material

9
TOC

Anti-Vibration Collet Gland Assemblies


Vibration and/or shock can be present in tubing systems, especially if the valve or fitting happens to be located on an
unsupported line near a compressor or pump. For this reason, Parker Autoclave Engineers coned-and-threaded connections are
offered with the Parker Autoclave Engineers Anti-Vibration Collet Gland Assemblies. Completely interchangeable with standard
Parker Autoclave Engineers high pressure connections, the Collet Gland Assemblies provide equally effective pressure handling
capability.

Catalog Number
O.D. Tubing Size
in (mm) Medium Pressure High Pressure
to 20,000 to 60,000
1/4 (6.35) KCBGLX40-316MC KCGL40-316
3/8 (9.53) KCBGLX60-316MC KCGL60-316
9/16 (14.3) KCBGLX90-316MC KCGL90-316
3/4 (19.1) KCBGLX120-316MC -
1 (25.4) KCBGLX160-316MC +KCBGLX160-316MC

1-1/2 (38.1) KCBGLX240-316MC -


+ 1” High Pressure to 43,000 psi (2964 bar)

Gland Nut
Slotted collet
Collet grips
tubing here for
anti-vibration Collet body
support
Valve or
fitting body

Collar*

Line contact
sealing

Series KCBGLX
Pressures to 20,000 psi (1380 bar)

Gland Nut
Slotted collet

Valve or
fitting body

Collet grips
tubing here for
anti-vibration
support

Collar*

Line contact
sealing

Series KCGL
Pressures to 60,000 psi (1440 bar)

* Collar not included in complete assembly.


10
TOC

Male/Female Adapters
Male/female adapters are designed to adapt a female connection direct to another size and/or type of connection. In selecting
an adapter involving two different sized connections, the larger connection should be on the male end where it is possible to
maximize the mechanical strength of the adapter. See valve fitting and tubing catalog for complete selection.

How to use the Ordering Chart:


1. Locate MALE end in the vertical column.
2. Locate desired FEMALE end of adapter across top of chart.
3. The catalog number of the required adapter is located at the
intersection of the two columns.

PAE Medium Pressure PAE High Pressure


1/4 3/8 9/16 3/4 1 1-1/2 1/4 3/8 9/16 9/16 1
FEMALE END (6.35) (9.53) (14.3) (19.1) (25.4) (38.1) (6.35) (9.53) (14.3) (14.3) (25.4)
SF250CX SF375CX SF562CX SF750CX SF1000CX SF1500CX F250C F375C F562C F562C40 F1000C43
MALE Fits this
Press. 20,000 20,000 20,000 20,000 20,000 15,000 60,000 60,000 60,000 40,000 43,000
END FEMALE
psi* (bar)
Connection (1380) (1380) (1380) (1380) (1380) (1034) (4140) (4140) (4140) (2758 (2964)

1/4 20,000
SF250CX 20M44K6 20M46K6 20M49K6 N/A N/A N/A 20M44K3 20M46K3 20M49K3 C/F N/A
(6.35) (1380)
PAE Medium Pressure

3/8 20,000
SF375CX 20M64K6 20M66K6 20M69K6 20M612K6 N/A N/A 20M64K3 20M66K3 20M69K3 C/F N/A
(9.53) (1380)
9/16 20,000
SF562CX 20M94K6 20M96K6 20M99K6 20M912K6 20M916K6 15M924K6 20M94K3 20M96K3 20M99K3 C/F 20M916K3
(14.3) (1380)
3/4 20,000
SF750CX N/A N/A 20M129K6 20M1212K6 20M1212K6 15M1224K6 N/A 20M126K3 20M129K3 20M129K40 20M1216K3
(19.1) (1380)
1 20,000
SF1000CX N/A N/A 20M169K6 20M1612K6 20M1616K6 15M1624K6 N/A 20M166K3 20M169K3 C/F 20M1616K3
(25.4) (1380)
1-1/2 15,000
SF15000CX N/A N/A 15M249K6 15M2412K6 15M2416K6 15M2424K6 N/A N/A C/F C/F C/F
(38.1) (1034)
1/4 60,000
F250C 20M44B6 20M46B6 20M49B6 N/A N/A N/A 60M44B3 60M46B3 60M49B3 C/F N/A
(6.35) (4140)
PAE High Pressure

3/8 60,000
F375C 20M64B6 20M66B6 20M69B6 20M612B6 N/A N/A 60M64B3 60M96B3 60M69B3 C/F N/A
(9.53) (4140)
9/16 60,000
F562C 20M94B6 20M96B6 20M99B6 20M912B6 20M916B6 N/A 60M94B3 60M96B3 60M99B3 40M99G40 43M916B3
(14.3) (4140)
9/16 40,000
F562C40 C/F C/F C/F 20M912G6 C/F N/A C/F C/F 40M99G40 40M99G40 C/F
(14.3) (2758)

1 43,000
F1000C43 N/A N/A 20M169B6 C/F C/F 15M1624B6 N/A N/A 43M169B3 43M169B40 C/F
(25.4) (2964)

*N/APressure Rating - The pressure rating of Parker Autoclave Engineers couplings is based on the lower rated connection used.
= Not Available
C/F = Consult Factory

Other Adapters
Parker Autoclave Engineers supplies many other types of adapters on special orders.
These include NPT, Buttweld, Header Coupling, QSS, EZ-Union, Male SAE-Oring, JIC connections and others.

Materials
All Parker Autoclave Engineers adapters are precision machined from cold-worked Type 316 stainless steel.
Other materials available on special order.
11
TOC

Adapter Couplings
The couplings shown here permit the joining of any combination of standard size Parker Autoclave Engineers tubing with
female-to-female couplings. Other couplings available on special order. See valve fitting and tubing catalog for complete
selection.

How to use the Ordering Chart:


1. Locate “A” connection in the vertical column.
2. Locate the desired “B” connection across the top of the chart.
3. The catalog number of the required coupling is located at the
intersection of the two columns. "A" "B"
CONNECTION CONNECTION
FEMALE FEMALE

“B” Connection
“A” Connection
PAE Medium Pressure PAE High Pressure
Tube 1/4 3/8 9/16 3/4 1 1-1/2 1/4 3/8 9/16 9/16 1
Press.
Size Connection
psi* (6.35) (9.53) (14.3) (19.1) (25.4) (38.1) (6.35) (9.53) (14.3) (14.3) (25.4)
in Type
(bar)
(mm) SF250CX SF375CX SF562CX SF750CX SF1000CX SF15000CX F250C F375C F562C F562C40 F1000C43
1/4 20,000
SF250CX 20FX4466 20F4666 20F4966 N/A N/A N/A 20F4463 20F4663 20F4963 C/F N/A
(6.35) (1380)
PAE Medium Pressure

3/8 20,000
SF375CX 20FX6666 20F6966 20F61266 N/A N/A 20F6463 20F6663 20F6963 C/F N/A
(9.53) (1380)
9/16 20,000
SF562CX 20FX9966 20F91266 20F91666 15FX92466 20F9463 20F9663 20F9963 C/F C/F
(14.3) (1380)
3/4 20,000
SF750CX 20FX12 20F121666 C/F N/A 20F12663 20F12963 C/F C/F
(19.1) (1380)
1 20,000
SF1000CX 20FX16 15FX162466 N/A 20F16663 20F16963 C/F C/F
(25.4) (1380)
1-1/2 15,000
SF1500CX 15FX24 N/A N/A C/F C/F C/F
(38.1) (1034)
1/4 60,000
F250C 60F4433 60F4633 60F4933 C/F N/A
(6.35) (4140)
PAE High Pressure

3/8 60,000
F375C 60F6633 60F6933 C/F N/A
(9.53) (4140)
9/16 60,000
F562C 60F9933 40F9933 43F91633
(14.3) (4140)
9/16 40,000
F562C40 40F9933 C/F
(14.3) (2758)
1 43,000
F1000C43 43F16
(25.4) (2964)

12
TOC

Ball Valves
High Pressure
Parker Autoclave Engineers Ball Valves are designed for on-off, high flow, high pressure
applications and provide superior quality with maximum performance. Our unique one-piece
trunnion mounted stem/ball eliminates the shear failure common in two-piece designs.
Our re-torqueable seat glands result in longer seat life and our low friction stem seal
reduces actuation torque and enhances cycle life.

Parker Autoclave Engineers ball valves can be operated safely up to 20,000 psi and up
to 500°F with the high temperature option. 2-way, 3-way & 4-Way Switching & Cross-
over styles are available.

Order Matrix: (See main catalog for all options including o-ring materials)

2B 4 S 20 M 4 -

Maximum Rated
Valve Series Ball Orifice Material End Connection Type2 End Connection Size Options
Pressure x10001
2B = 2 Way 33 = 3/16” S = 316 SS 5 L = Low Pressure 4 = 1/4” HT = High Temp.
3B = 3 Way 4 = 1/4” for other 10 M = Medium Pressure 6 = 3/8” AO = Air to Open
options
3BD = 3 Way Diverter 6 = 3/8” 15 H = High Pressure 8 = 1/2” AC = Air to Close
contact factory
4B5 = 4 way Crossover 8 = 1/2” 20 P = NPT 9 = 9/16” AOC = Air to Open/Close
4BS5 = 4 Way Switching 124 = 3/4” 12 = 3/4” EO1 = Electric 120VAC
164 = 1” 16 = 1” EO2 = Electric 220VAC
24 = 1-1/2” EO3 = Electric 240VDC
Note: Matrix can build valves not yet available, refer to main catalog for exact size/valve series selection
1 = Pressure chosen after considering orifice size, connection and temperature requirements - see main catalog for all available operations.
2 = Low Pressure connection sizes 1/8” through 1/2”, Medium and High Pressure connections not available in 1/8” or 1/2”, NPT connections rated
to 15,000 psi up to 1/2” and 10,000 psi for 3/4” and 1”.
3 = Only available in 3-Way valve models
4 = Only available in 2-Way valve models
5 = 4B & 4BS only available in 3/8" orifice size

Double Block and Bleed Ball Valves


Parker Autoclave Engineers series 6DB 3/8" bore and 10DB 5/8" bore Double Block and Bleed Valve
is a 2-stem ball valve combined with a separate needle valve that provides a convenient method of
blocking and bleeding an instrument injection port, gauge, or provides drain line isolation, decreasing
leak points and reducing overall weight. These full port quarter turn double block and bleed ball valves
are designed for operation up to 15,000 psi (1035 bar).

Subsea Series Ball Valves


Parker Autoclave Engineers subsea ball valves have been designed to fulfill the ever
growing demand by the Petroleum Industry for externally pressurized components.
Utilizing the proven technologies that make our ball valve “best in class” we’ve incorporated
the necessary design features to provide a reliable externally pressurized valve for the subsea
industry and simplified the mounting for ROV, diver, or remote actuation capabilities. Our
2-way and 3-way Subsea Series valves are able to withstand up to 20,000 psi (1380 bar)
internal pressures at up to 12,500’ (3810 meters) water depth.

13
TOC

Instrument Quality Gauges


Materials and Features
• Accuracy within ±0.5% of full scale range
• Glass dial cover/solid front aluminum alloy case
• Blow-out back panel for pressure relief in the event of Bourdon tube failure
• 316 Stainless steel Bourdon tubes**
• Precision stainless steel movement for accuracy and resistance to atmospheric corrosion
• Pointer zero adjustment located on front of gauge behind dial cover for convenience

Instrument quality gauges


• Flush panel mounting - Panel mounting kits are stocked to permit flush panel mounting of any instrument quality
gauge. These will be furnished at an additional charge when specified on order -- add “PM” to order number.

**Bourdon Tube material for 0-80,000 psi (0-5116 bar) and 0-50,000 psi (0-3447 bar) gauge is Inconel 718.
Bourdon Tube material for 0-30,000 psi (0-2068 bar) gauge is K Monel.

P-Style Bottom Connection Gauge


Catalog Pressure Range Minor Interval Value Dial Diameter
Number psi (bar) psi (bar) inches (mm)
P-0481-CG 0-5000 (0-350) 50 (2) 4-1/2 (114)
P-0482-CG 0-10,000 (0-700) 100 (5) 4-1/2 (114)
P-0483-CG 0-15,000 (0-1000) 100 (10) 4-1/2 (114)
P-0487-CG 0-20,000 (0-1400) 200 (20) 4-1/2 (114)
P-0488-CG** 0-30,000 (0-2000) 250 (20) 6 (152)
P-0489-CG** 0-50,000 (0-3500) 500 (20) 6 (152)
P-0490-CG** 0-80,000 (0-5500) 1,000 (50) 6 (152)

Note: Gauges available with back connections. Add B to the base catalog number. Ex: P-047B-CG
1/4” (F250C) Coned-and-Threaded Connection Furnished with Collar and Gland

14
TOC

Manifolds and Relief Valves


Manifold Blocks
Specialty pressure manifolds minimize space requirements and reduce installation
time necessary to plumb a pressure system. In addition, by reducing the number of
components used in a system, manifolds reduce the number of potential leak joints.

Parker Autoclave Engineers will design and build pressure manifolds to meet specific
installation, layout and pressure requirements. These manifolds are capable of withstanding
pressures from vacuum to 60,000 psi (4137 bar), and are available in a variety of materials and sizes.
These manifolds are appropriate wherever pressure tubing systems are utilized.

Relief Valves: RVP-Metal Seat and RVS-Soft Seat Series


Series RVP & RVS relief valves provide reliable venting of gases or liquids for set pressures from
1,500 psi (103 bar) to 60,000 psi (4140 bar). Standard temperature range on RVP models is -423° F
to 400° F (-253° C to 204° C). High temperature option to 750° F (400° C) also available.
Temperature range on RVS model is 32° F to 400° F (0° C to 204° C).

These precision valves are designed for pressure gas systems, cryogenic systems, petrochemical
applications and other special systems. They are capable of handling air, gases, steam, vapor and
liquids. They are not recommended for steam boiler applications and are not ASME code stampable.

Relief valves are designed to open proportionally to increasing back pressure and, therefore, are not
recommended for applications requiring immediate full valve flow at set pressure. Full flow of relief
valve is defined at 10% over set pressure.
RVP & PRVP Metal Seat, RVS & PRVS Soft Seat Series Relief Valve

Connection Size and Type Orifice Pressure Rating psi (bar) @ 100ºF (38ºC)
Catalog
Inlet Outlet Diameter Minimum Maximum Maximum
Number*
Connection Connection Inches (mm) Setting Setting Back Pressure
5PRVP8072 1/2" FNPT 3/4 FNPT 0.312 (7.92) 3,000 (210) 5,000 (345) 500 (35)
10PRVP8072 1/2" FNPT 3/4 FNPT 0.250 (6.35) 5,000 (345) 10,000 (690) 500 (35)
15PRVP8072 1/2" FNPT 3/4 FNPT 0.188 (4.78) 10,000 (690) 15,000 (1035) 500 (35)
5RVP9072 SF562CX (9/16" MP) 3/4 FNPT 0.312 (7.92) 3,000 (210) 5,000 (345) 500 (35)
10RVP9072 SF562CX (9/16" MP) 3/4 FNPT 0.250 (6.35) 5,000 (345) 10,000 (690) 500 (35)
15RVP9072 SF562CX (9/16" MP) 3/4 FNPT 0.188 (4.78) 10,000 (690) 15,000 (1035) 500 (35)
20RVP9072 SF562CX (9/16" MP) 3/4 FNPT 0.156 (3.96) 15,000 (1035) 20,000 (1380) 500 (35)
30RVP6072 F375C (3/8" HP) 3/4 FNPT 0.125 (3.18) 15,000 (1035) 30,000 (2070) 500 (35)
45RVP9072 F562C (9/16" HP) 3/4 FNPT 0.093 (2.36) 25,000 (1725) 45,000 (3100) 500 (35)
60RVP6072 F375C (3/8" HP) 3/4 FNPT 0.078 (1.98) 30,000 (2070) 60,000 (4140) 500 (35)
75RVP5072 F312C150 (5/16" UHP) 3/4 FNPT 0.062 (1.57) 37,000 (2550) 75,000 (5170) 500 (35)
5PRVS8072 1/2" FNPT 3/4 FNPT 0.312 (7.92) 1,500 (103) 5,000 (345) 500 (35)
10PRVS8072 1/2" FNPT 3/4 FNPT 0.250 (6.35) 5,000 (345) 10,000 (690) 500 (35)
15PRVS8072 1/2" FNPT 3/4 FNPT 0.188 (4.78) 10,000 (690) 15,000 (1035) 500 (35)
5RVS9072 SF562CX (9/16" MP) 3/4 FNPT 0.312 (7.92) 1,500 (105) 5,000 (345) 500 (35)
10RVS9072 SF562CX (9/16" MP) 3/4 FNPT 0.250 (6.35) 5,000 (345) 10,000 (690) 500 (35)
20RVS9072 SF562CX (9/16" MP) 3/4 FNPT 0.156 (3.96) 10,000 (690) 20,000 (1378) 500 (35)

* Maximum pressure rating based on the lowest rating of any component. Actual working pressure may be determined by tubing pressure rating, if lower.
15
Note: For pressure rating see selection chart. 1 Include suffix from original valve for correct options
TOC

Tools
Manual Coning and Threading Tools
Parker Autoclave Engineers manufactures a manual coning tool for optimum coning
performance with tubing sizes up to 9/16” (14.3 mm) O.D. This is a precision
quality manual tool to permit on-site end preparation for AE medium and high
pressure tubing installations. Interchangeable collets for each size tubing provide
proper centering of tubing. The cutting feed arrangement permits the operator to
control the depth of cut to assure against work hardening effects. Interchangeable
tool steel cutting blades are used in pairs to assure more accurate and faster con-
ing and are designed to square-off and finish the tube as the cone is completed.
There is a provision for applying metal cutting lubricants to the cutting zone.

The threading die holder is designed to hold the appropriate die for any of the
standard Parker Autoclave Engineers tubing sizes through 9/16” (14.3 mm) O.D. Complete Coning & Threading Kits
Interchangeable guide bushings properly guide the tool for accurate thread cutting. Medium Pressure, 1/4" to 9/16" = KMCT-MT
High Pressure, 1/4" to 9/16" = KMCT-HT
Note: Complete tool kits are available. Consult factory

Feed Nut

Coning Tool
Housing

Collet Nut Coning Tool

Oil/Chip Reservoir*
Vice Arm*
Threading Tool
* For coning tool with optional Vice Arm and Oil/Chip Reservoir, add RS suffix to model number. Ex: MCTM4-RS
Tube Size Coning Tools and Components Catalog Number Threading Tools and Components Catalog Number
O.D. I.D. Tool with Coning Blades Tool with Tool Threading Die
Collet Guide Bushing
in (mm) in (mm) Collet & Blades (Set of 2) Die & Bushing Only Order No. Size-type*
PAE Medium Pressure

1/4 (6.35) .109 (2.77) MCTM4 90248 CT4BX 402A 402 P-0214 1/4-28 1010-0343

3/8 (9.53) .203 (5.16) MCTM6 90250 CT6BX 402C 402 P-0215 3/8-24 1010-0344

9/16 (14.3) .312 (7.92) MCTM920 90251 CT9BX 402E 402 P-0216 9/16-18 1010-0345

9/16 (14.3) .359 (9.12) MCTM910 90251 CT9BXX 402E 402 P-0216 9/16-18 1010-0345

1/4 (6.35) .083 (2.11) MCTH4 90248 CT4B 402A 402 P-0214 1/4-28 1010-0343
PAE High Pressure

3/8 (9.53) .125 (3.18) MCTH6 90250 CT6B 402C 402 P-0215 3/8-24 1010-0344

9/16 (14.3) .188 (4.78) MCTH960 90251 CT9B 402E 402 P-0216 9/16-18 1010-0345

9/16 (14.3) .250 (6.35) MCTh940 90251 CT9B40 402E 402 P-0216 9/16-18 1010-0345

Cutting Oil: P-8784


• All threads for PAE medium pressure and high pressure tubing are LH national fine (class 2).
Note: Manual coning and threading tools for 3/4” (19.1 mm) and 1” (25.4 mm) O.D. medium pressure tubing are not available. Model AEGCTM-2 Power
Coning-and-Threading Machine is recommended for this tubing. A minimum of 3” (76 mm) straight length is required to perform coning and threading operation for manual coning tool.

16
TOC

Tools
PAE Micrometer Adjustable Torque Wrench
P-1680 20 to 150 ft. lbs. (27 to 203 Nm)
91020 75 to 250 ft. lbs. (102 to 339 Nm)
Accurate tightening for all Parker Autoclave Engineers valve packing
glands and tube nuts is essential. The wrench can be adjusted to the
ranges shown and is used with interchangeable wrench adapters for hex sizes
from 1/2” through 1-7/8”. Part numbers for wrench adapters are listed on chart.

Packing Gland or
1/2 9/16 5/8 3/4 13/16 7/8 15/16 1 1-1/16 1-3/16 1-3/8 1-1/2 1-7/8
Gland Nut Hex Size
(12.7) (14.3) (15.9) (19.05) (20.6) (22.2) (23.8) (25.4) (27) (30.2) (34.9) (38.1) (47.6)
in (mm)
Wrench Adapter
P-1681 P-1682 P-1683 P-9813 P-1685 P-1686 P-1687 P-9901 P-1688 P-1689 P-1690 P-6040 P-10076
Number

* For
For Gland Nut size for each connection, see Gland Torque chart in Tools & Installation catalog.
Packing Gland sizes, see Packing Gland Torque chart in same.

Hydraulic Tube Bender


For single pass bending of high pressure tubing. The Parker Autoclave
Engineers hydraulic tube bender is designed to bend heavy wall
tubing quickly, accurately and reliably with only one setup. The tube
bender is complete with pump, cylinder, frame and bending shoes
which are self-contained in a portable, lockable case.
(Order number: HTB)

Air operated hydraulic pump option available in place of hand pump.


(Order Number: HTB-A)

Coning and Threading Machine


Ordering Numbers: 115VAC Version, Model # AEGCTM-2G (CE Version/220VAC: Model #AEGCTM-2E-CEG)

Separate heads for coning and threading are powered by a single motor and drive system.
Available models cone and thread Parker Autoclave Engineers medium and high pressure tubing.

Approximate dimensions: 56” high, 28” wide and 20” deep (1.4 m x .7 m x .5 m).
Shipping weight is 350 pounds (159 kg). Tooling ordered separately. Consult factory.

Features
• One-half hp motor, 115 VAC 60 Hz (220 VAC 50 Hz) volt capacitor start.
• No reversing necessary on threading operation; pop-open die prevents thread damage.
• Complete tooling is available; specify tooling sizes required.
• Coning head has feed wheel for easy, precision feeding.
• Complete with oil pump and reservoir.
• Unit mounted on stand complete with locking casters for ease of mobility and stability.
• Available with optional reservoir heater
• CE mark standard on 220 VAC 50 Hz models

17
TOC

Connections
Parker Autoclave Medium Pressure SF** (SM Series Valves)
20,000 psi Maximum Pressure

Tube Outside Dimensions - inches (mm)


Connection
Diameter
Type A B C D F H
(Inches)
60°
25/64 .28 .50 .19 .109
1/4 SF250CX 7/16 -20
(9.9) (7.1) (12.7) (4.8) (2.8) B
Thread
A
33/64 .38 .63 .31 .203 Drill
3/8 SF375CX 9/16 -18 F
(13.1) (9.6) (16.0) (7.9) (5.2)
C
D
SF562CX10* 3/4 .44 .75 .50 .359 (9.1)
9/16 13/16 -16
SF562CX20 (19.1) (11.1) (19.1) (12.7) .312 (7.9) 5°

SF750CX10* 61/64 3/4 -14 .50 .94 .63 .516 (13.1) Weep
3/4 hole
SF750CX20 (24.2) see Note 1 (12.7) (23.9) (16.0) .438 (11.1) H

SF1000CX10* 1-19/64 .81 1.31 .88 .688 (17.5)


1 1-3/8 -12 Note 1 = NPS Male Tap
SF1000CX20 (32.9) (20.6) (33.3) (22.4) .562 (14.3)
1.790 1.00 1.59 1.38 .937
1-1/2 SF1500CX 1-7/8 -12
(45.47) (25.4) (40.38) (35.05) (23.80)
* Connection used in fittings but rated for 20,000 psi (1379 bar). CX10 connection versions are typically rated to 15,000 psi
Note 1: 3/4-14 ia a straight pipe thread.

Parker Autoclave High Pressure F** (30, 43 SC and 30, 40, 60VM Valves)
60,000 psi Maximum Pressure

Tube Outside Dimensions - inches (mm)


Connection
Diameter
Type A B C D F H
(Inches)
60°
33/64 .38 .44 .17 .094
1/4 F250C 9/16 -18 B
Thread
(13.1) (9.7) (11.1) (4.3) (2.4) A
Drill
11/16 .53 .62 .26 .125 F
3/8 F375C 3/4 -16
(17.4) (13.5) (15.7) (6.6) (3.2) 5° C D
1-3/64 .63 .75 .38 .188
9/16 F562C 1-1/8 -12
(26.6) (16.0) (19.1) (9.7) (4.8)
Weep
1-3/64 .63 .75 .38 .250 hole
9/16 F562C40 1-1/8 -12 H
(26.6) (16.0) (19.1) (9.7) (6.4)
1-19/64 .81 1.31 .88 .438
1 F1000C43 1-3/8 -12
(32.9) (20.6) (33.3) (22.4) (11.1)

Note: All dimensions are shown for reference only and should not be considered as actual machining dimensions.
For port Diameter please see orifice sizes for specific valves and fittings. All threads are manufactured to a class 2A or 2B fit.

18
TOC

Flow Calculations
Coefficient of flow (CV) for a valve is the volume of water in U.S. gallons per minute at room temperature...which will flow
through the valve with the stem fully open...with a pressure drop of 1 psi across the valve. CV is the valve sizing factor that
permits selection of the appropriate valve to meet the flow requirements of a given fluid system.

The CV values shown on the valve ordering pages represent the full-open CV for that valve. In determining estimated capacity,
this CV value should be used in the formulas which follow.

Flow Formulas
Liquids V = CV √ P1 - P2
√SGF
• Flow, U.S. gal./min.
• Flow, lb./hr.
W = 500 CV √ (P1 - P2) /SGF

Gases **
Q = 42.2 CV √ (P1 - P2) (P1 + P2)
• Flow, SCFH √ SGF
• Flow, SCFH (temperature corrected)
• Flow, lb./hr. *
Q = 963 CV √ (P1 - P2) (P1 + P2)
√ SGF TF
Saturated Steam
*
• Flow, lb./hr. W = 3.22 CV √ (P1 - P2) (P1 + P2)/SG

*
Super Heated Steam W = 2.1 CV √ (P1 - P2) (P1 + P2)

• Flow, lb./hr. W = 2.1 CV √ (P1 - P2) (P1 + P2)


*

(1 + 0.0007 TS)

Specific gravity (SG ) Specific gravity (SGF ) Formula


typical Gases typical Liquids Nomenclature

SG @ RT SG @ RT V = Flow, U.S. gallons per minute (GPM)


Gases Relative Liquids Relative Q = Flow, standard cu. ft. per hr. (SCFH)
to Air to Water
W = Flow, pounds per hour (lb./hr.)
Acetylene 0.897 Acetone 0.792
Air 1.000 Alcohol 0.792 P1 = Inlet pressure, psia (14.7 + psig)
Ammonia 0.587 Benzine 0.902 P2 = Outlet pressure, psia (14.7 + psig)
Argon 1.377 Gasoline 0.751
SGF = Liquid specific gravity (water = 1.0)
Butane 2.070 Gasoline, nat. 0.680
Carbon Dioxide 1.516 Kerosene 0.815 SG = Gas specific gravity (air = 1.0)
Ethylene 0.967 Pentane 0.624 TF = Flowing temp., °R absolute (460 + °F)
Helium 0.138 Water 1.000
TS = Superheat in °F
Hydrogen 0.0695
Methane 0.553 CV = Valve coefficient of flow, full open
Nitrogen 0.966
Oxygen 1.103
Effect of flowing temperatures on gas flow are minimal for temperatures between 30°F and 150°F. Correction should
Propane 1.562 * be included if temperatures are higher or lower.
Sulpher Dioxide 2.208
** Where outlet pressure P is less than /2 inlet pressure P1, the term: √ (P1 - P2) (P1 + P2): becomes 0.87 x P1.
1
2

Note: Maximum CV values in this catalog have been determined in accordance with the Fluid Controls Institute report
FCI 58-2. “Recommended Voluntary Standards for Measurement Procedure for Determining Control Valve Flow
Capacity,” including procedure, design of the test stand and evaluation of the data.

19
TOC

Sour Service Products


Parker Autoclave Engineers designs and builds high pressure valves, fittings, and tubing specifically for use with Sour Oil and
Gas (H2S) and meet or exceed all requirements of NACE MR0175-2002 (NACE to current revisions available). Our SOG line
of products are manufactured with materials and procedures specified to meet the NACE requirements. Valves and Fittings
for standard service are rated for working pressures up to 60,000 psi (4140 bar) at 100°F (38°C). Type SOG components are
rated up to 30,000 psi (2068 bar) at 100°F (38°C). Valves are furnished without collars and glands unless otherwise specified.
Note: Refer to main catalog for full product information.

WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE
DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users
having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to
the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the
products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be governed
by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).

© 2022 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-0115BE April 2022

Caution! Do not mix or interchange parts or tubing with those of


other manufacturers. Doing so is unsafe and will void warranty.

Caution! Parker Autoclave Engineers Valves, Fittings and Tools are


not designed to work with common commercial instrument tubing
Instrumentation Products Division
and will only work with tubing built to Parker Autoclave Engineers
Autoclave Engineers Operation
AES Specifications. Failure to do so will void warranty.
8325 Hessinger Drive
Erie, Pennsylvania 16509-4679 USA
PH: 814-860-5700 FAX: 814-860-5811
www.Autoclave.com | www.Parker.com/ipd ISO-9001 Certified