METERING

Efficient metering and monitoring at affordable price

www.himel.com
METERING

HP606 Digital Panel Meters HDT(S)S606 Three-phase Four-wire Watt-hour


Meter

HP606

HDT(S)S606

Meter model: Amperemeter, Voltmeter, Current specification: 1.5(6)A, 3(6)A, 5(20)A, 5(40)A,
Combination meter, Multifunction Meter 5(60)A, 20(80)A, 10(100)A
Connection type: Single-phase / Three-phase Conection Type: Three-phase Four-wire
Accuracy: class 0.5 Accuracy: Class 1
Frequency: 45-65Hz Frequency: 50/60Hz
Dimension types: 3 types (96, 72, 48)

H72 & H96 Panel Meters HLMK Current Transformers

HLMK
H96 H72

Specification: 72x72mm, 96x96mm Rated primary current: 30A-5000A


Type: Ammeter, Voltmeter, Frequency Meter Rated secondary current: 5A
Frequency: 50/60Hz Maximum rated voltage: 0.66kV
Accuracy class: 0.5, 1.0
Frequency: 50Hz

HDDS606 Single-phase Watt-hour Meter

HDDS606

Current specification: 1.5(6)A, 2.5(10)A, 5(20)A, 5(30)A,


10(40)A, 15(60)A, 20(80)A,10(100)A
Conection Type: Single-phase
Accuracy: Class 1
Frequency: 50/60Hz
METERING

Range Presentation
HP606 is Himel range of new Digital Meters:
• Applied to power monitoring and panel builder cabinet
• Product types: current, voltage, combination, and multifunction
• Dimension types: 3 types (96, 72, 48)

Features

◆ New design and elegant appearance: material of high permeability plexiglass, LED or LCD display; and wide visual range
◆ Accurate metering and reliable performance: high accuracy and resolution ratio; high ability of overloading
◆ Four-remote control: teleindication, telecontrol, Telemetering, and remote regulating
√ Teleindication: build communication with data collector, network module, and workstation via Rs485
√ Telecontrol: operation on local or remote workstation (off-site), e.g. remote tripping and closing
√ Telemetering: remote parameters adjustment
√ Remote regulating: remote parameters metering

Range Presentation
HDDS606 and HDT(S)S606 series are Himel range of Electronic Watt-hour Meter, which provide:
• Measuring the active energy in the single-phase or three-phase AC power network at frequency
of 50Hz or 60Hz
• Measuring the active energy of enterprises, transformer sub-station or power stations, and be
used as automatic meters of power transmission and distribution network

Features
◆ Smaller and Elegant:
• 50% smaller in size to save installation space
• Upgraded appearance design
◆ Accurate Measurement & Safe and Reliable:
• Automatic calibration for inspection
• Three lead sealings: factory, verification and installation; more secure for electricity anti-stealing.
◆ Well Designed & Intelligent and Convenient:
• Wider current range, and easier for model selection
• First limit design of bump on the tail cover in our industry, and flip angle of the tail cover can be more than135°
• More convenient and firming on wiring.
◆ Qualified Materials & Excellent Performance:
• Temperature rise is only 15K, which is far less than national standard 25K.
• Power loss is less than 0.5W.
• Heat deformation temperature reaches to 200°C

Range Presentation Features

HLMK Series is Himel range of Current ◆ 100% pure copper varnished wire
Transformer, to measure and transform high ◆ Optimized electric conductivity, less power
current to low current loss and better stability
◆ Shell is made of flame retardant PC material
◆ Maximum rated voltage is 0.66kV
METERING

HP606 Digital Panel Meters


Standard: IEC60051

Product Overview Features Online Content


• New design, and it's applied to power ◆ New design and elegant appearance: material of high
monitoring and panel builder cabinet permeability plexiglass, LED or LCD display; and wide
• Product types: current, voltage, combination, visual range

and multifunction Accurate metering and reliable performance: high
• Dimension types: 3 types (96, 72, 48) ◆ accuracy and resolution ratio; high ability of overloading
Four-remote control: teleindication, telecontrol, HP606
Model Selection Telemetering, and remote regulating
√ Teleindication: build communication with data
The HP606 Series includes the following models:
collector, network module, and workstation via Rs485
• HPZ single/three-phase voltmeter
√ Telecontrol: operation on local or remote workstation
• HPA single/three-phase amperemeter
(off-site), e.g. remote tripping and closing
• HPD combination meter
√ Telemetering: remote parameters adjustment
• HPDM multifunction meter
√ Remote regulating: remote parameters metering
Selection Code
Input
Model Panel dimension Meter structure Display mode Range
mode

HP*606 L 72 P 1 Y 5A
HPA606: HPA606 L: AC 48: 96×48 mm (only P: Programmable Display 1: One-row LED display NA 5A: Secondary
Amperemeter for single-phase meter) Instrument 1A: Secondary
S: DO+RS485
72: 72×72 mm 1: One-row LED display
4: Three-row LED display

96: 96×96 mm P: Programmable Display 1: One-row LED display


Instrument 4: Three-row LED display

S: DO+RS485 4: Three-row LED display

HPZ606: HPZ606 L: AC 48: 96×48 mm (only P: Programmable Display 1: One-row LED display Y: 100V NA
Voltemeter for single-phase meter) Instrument O: 600V
S: DO+RS485

72: 72×72 mm P: Programmable Display 1: One-row LED display


Instrument 4: Three-row LED display
S: DO+RS485

96: 96×96 mm P: Programmable Display 1: One-row LED display


Instrument 4: Three-row LED display

S: DO+RS485 4: Three-row LED display

HPD606: HPD606 L: AC 72: 72×72 mm P: Programmable Display 4: Three-row LED display Y: 100V 5A: Secondar y
Combination meter Instrument O: 600V 1A: Secondary
96: 96×96 mm T: RS485

HPDM606: L: AC 72: 72×72 mm P: Programmable Display 3Y: Three-phase LCD display Y: 100V 5A: Secondary
HPDM606 Instrument (only for multifunction O: 600V 1A: Secondary
Multifunction meter T: RS485 meter)
4: Three-row LED display
96: 96×96 mm P: Programmable Display Y: 100V 5A: Secondary
Instrument O: 600V 1A: Secondary
T: RS485

Note: Normally the combination meter is composed of voltage, current, and frequency.
If customer needs more functions, then a multi-function meter is required.
METERING

HP606 Digital Panel Meters


Standard: IEC60051

Range Table
Direct connection AC: 0.1~5A DC: 0~5A
Current range AC: external current transformer 5A/5A 10kA/5A
DC: current shunt 75mV 10kA/75mV
Direct connection AC: 3~600V; DC: 0~600V
Voltage range AC: external voltage transformer 380V/100V~ 380kV/100V;
DC: external resistor of 750V~ 1.5kV
Frequency range 45Hz~65Hz
Power factor 0.5 (lead) ~1 ~0.5 (lag)

Technical Parameters
Network system Single-phase & Three-phase
Voltage Overload Continuous: 1.2×Un; Instantaneous: 2×Un for lasting 1s
Input
Current Overload Continuous: 1.2×In; Instantaneous: 10×In for lasting 5s
Frequency 45~65Hz
Switch input (DI) Photocoupler Isolation of passive dry contact
Output of two-loop passive relay, contact capacity: 3A/30VDC,3A/250VAC,
Switch output (DO) Values of upper and lower limit alarm, hysteresis can be set as what you want.
Output method: remote control (used as switch output) or off-limit alarm
Electrical energy pulse Two-loop electrical pulse output
Function module Active power: 8000imp/kwh
Electrical energy pulse constant
Reactive power: 8000imp/kvarh
Method RS485
Protocol MODBUS-RTU
Communication
Baud rate 1200, 2400, 4800, 9600 bps
Parity bit Odd parity, even parity, no parity
(1) Long lifecycle and highlighted LED display;
Display Display mode
(2) Wide viewing LCD display
Voltage, current, frequency, active
Class 0.5
Accuracy Class power,power factor
active energy Class 1
IP Protection IP54
Range AC220V
Auxiliary power supply
Power consumption < 5VA
Standard IEC 60068-2, IEC 61010-1, IEC 60529, IEC 61000-4, IEC 61557-1

Working Environment and Condition


Allowed ambient temperature: -10°C~+45°C ;
Ambient temperature
limited operating temperature: -25°C~+55°C
Environmental humidity ≤ 85%RH

No mold and insect, no salt spray, no dewing, light dust and sand are
Working environment allowed, withstand mechanical force of instruments is the basic type,altitude
≤ 2000m.
METERING

HP606 Digital Panel Meters


Standard: IEC60051

Communication Application

Local workstaion
Local workstation

RS485

HP*606 Series Digital Meter Data Collector Network Module Remote workstaion
HP*606 Series Digital Meter Data Collector Network Module Remote workstation
METERS

HP606 Digital Panel Meters


Standard: IEC60051
HP606 Series Digital Display Electric Measuring Instrument

Product Dimension

·Single-phase Amperemeter / Voltmeter Dimension

Unit: mm
Dimension Mounting
Model
a b c d e f g hole size
72 72 72 100.5 13.5 74.5 66 66 67 67

96 96 96 100.5 13.5 74.5 90.5 90.5 92 92

48 48 96 100.5 13.5 74.5 90.5 43.5 45 92

Three-phase Amperemeter / Voltmeter Dimension

Unit: mm
Dimension
Model Mounting hole size
A B C D

72 72 72 66 88 67*67

96 96 96 90.5 88 92*92

·Three-phase Combination / Multifunction Meter Dimension

Unit: mm
Unit: mm
Dimension
Model Mounting hole size
A B C D

72 72 72 66 88 67*67

96 96 96 90.5 88 92*92
METERS

HP606Digital
HP606 DigitalMeters
Series Panel Display Electric Measuring Instrument
Standard: IEC60051

Wiring Diagram for Terminal Block


Wiring Diagram for Terminal Block
·Single-phase
Single-phaseAmperemeter
・ Amperemeter / /Voltmeter
Voltmeter

Direct
DirectConnection
Connection External
External transformer
transformer
connection
connection

Three-phase Amperemeter
·Three-phase Amperemeter

Three-phase four-wire
Three-phase
Three-phase three-wire
three-wire Three-phase four-wire
METERING

HP606 Digital Panel Meters


Standard: IEC60051
HP606 Series Digital Display Electric Measuring Instrument

Wiring Diagram for Terminal Block

Three-phase Voltmeter

Three-phase three-wire Three-phase four-wire

Three-phase Combination and Multifunction meters

Direct Connection Direct Connection

External voltage External voltage


transformer connection transformer connection
Three-phase three-wire Three-phase four-wire
METERING

H72 & H96 Panel Meter


Standard: IEC60051

Range Presentation Features Online Content

H72 & H96 series is Himel range of panel meters which ◆ 72*72mm dimension for H72 series, while
provides: 96*96mm dimension for H96 series;
• H72T/H72L & H96T/H96L can be used to measure the ◆ For amperemeter with direct connection,

current, voltage or frequency in the AC circuit maximum current can reach 50A in AC circuit,
while maximum current is 20A in DC circuit;
• H72C & H96C can be used to measure the current or
◆ For voltmeter with direct connection, H72
voltage in the DC circuit
maximum voltage can reach 600V in both AC
• They are mainly used as indicating instrument for high
and DC circuits;
or low-voltage switch cabinet, power supply cabinet,
◆ Accuracy of amperemeter and voltmeter is
control cabinet and other electric-control facilities in the class 1.5, and accuracy of frequency meter is
AC transmission circuit system. class 1.0.
H96

Selection Code
Primary Current /
Range name Connection method
Voltage / Frequency

H72 50 A
H72TA: H72 AC Amperemeter 5: 5A Default: External transformer connection
H96TA: H96 AC Amperemeter 20: 20A A: Direct connection (1-20A)
...
5000: 5000A
10000: 10000A

H72LV: H72 AC Voltmeter 300: 300V Default: Direct connection (30-600V)


H96LV: H96 AC Voltmeter 500: 500V
600: 600V

H96CV: H96 DC Voltmeter 300: 300V Default: Direct connection (3-600V)


500: 500V
600: 600V

H72LHZ: H72 frequency meter 01200V


H96LHZ: H96 frequency meter

Note: • CT must be purchased separately for Amperemeter above 20A


• the last digit of selection code plus WG by default

Technical Parameters
Panel Meters H72/H96
Standard IEC 60051
Dielectric strength test Frequency 50/60Hz, Voltage 2000V, duration 1 minute
Impact test Maximum acceleration 147m/s2
Response time ≤4s
Angular Deflection 90°
Temperature -25°C ~ +40°C
Humidity (25%-80%) RH
Environment No mildew, insects, salt mist, dew, sand and dust are permitted
Installation Installed vertically
IP Grade IP42
METERING

H72 & H96 Panel Meter


Standard: IEC60051

H72 series panel meter provides


◆ H72T/H72L applies to measure the current, voltage or frequency in the AC circuit

◆ H72C applies to measure the current or voltage in the DC circuit

◆ Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power supply cabinet, control cabinet and

other electric-control facilities in the AC transmission circuit system

Order Information

Type Accuracy rating Specification Note Dimensions (mm) Reference

30/5A 72×72×67.5 H72TA30WG

40/5A 72×72×67.5 H72TA40WG

50/5A 72×72×67.5 H72TA50WG

60/5A 72×72×67.5 H72TA60WG

75/5A 72×72×67.5 H72TA75WG

80/5A 72×72×67.5 H72TA80WG

100/5A 72×72×67.5 H72TA100WG

150/5A 72×72×67.5 H72TA150WG


AC Type
160/5A 72×72×67.5 H72TA160WG
External connection
200/5A transformer 72×72×67.5 H72TA200WG
1.5 2 times of current
250/5A 72×72×67.5 H72TA250WG
Ammeter overload
300/5A 72×72×67.5 H72TA300WG

400/5A 72×72×67.5 H72TA400WG

600/5A 72×72×67.5 H72TA600WG

800/5A 72×72×67.5 H72TA800WG

1000/5A 72×72×67.5 H72TA1000WG

1600/5A 72×72×67.5 H72TA1600WG

5000/5A 72×72×67.5 H72TA5000WG

10000/5A 72×72×67.5 H72TA10000WG

AC Type
5A 72×72×67.5 H72TA5AWG
Direct connection

1.5 5A DC Type 72×72×67.5 H72CA5AWG

300V AC Type 72×72×67.5 H72LV300WG

500V 72×72×67.5 H72LV500WG


Voltmeter 1.5
600V 72×72×67.5 H72LV600WG

500V DC Type 72×72×67.5 H72CV500WG

Frequency meter 1.0 45-55HZ (200V) AC Type 72×72×67.5 H72LHZ01200VWG


METERING

H72 & H96 Panel Meter


Standard: IEC60051

H96 series panel meter provides


◆ H96T/H96L applies to measure the current, voltage or frequency in the AC circuit

◆ H96C applies to measure the current or voltage in the DC circuit

◆ Mainly be used as an indicating instrument for high or low-voltage switch cabinet, power supply cabinet, control cabinet and

other electric-control facilities in the AC transmission circuit system

Order Information

Type Accuracy rating Specification Note Dimensions (mm) Reference

30/5A AC Type 96×96×67.5 H96TA30WG

40/5A 96×96×67.5 H96TA40WG

50/5A 96×96×67.5 H96TA50WG

60/5A 96×96×67.5 H96TA60WG

75/5A 96×96×67.5 H96TA75WG

80/5A 96×96×67.5 H96TA80WG

100/5A 96×96×67.5 H96TA100WG

150/5A 96×96×67.5 H96TA150WG

160/5A 96×96×67.5 H96TA160WG

200/5A 96×96×67.5 H96TA200WG


External connection
1.5 transformer
250/5A 96×96×67.5 H96TA250WG
Ammeter
300/5A 96×96×67.5 H96TA300WG

400/5A 96×96×67.5 H96TA400WG

600/5A 96×96×67.5 H96TA600WG

800/5A 96×96×67.5 H96TA800WG

1000/5A 96×96×67.5 H96TA1000WG

1600/5A 96×96×67.5 H96TA1600WG

5000/5A 96×96×67.5 H96TA5000WG

10000/5A 96×96×67.5 H96TA10000WG

AC Type
5A 96×96×67.5 H96TA5AWG
Direct connection

1.5 5A DC Type 96×96×67.5 H96CA5AWG

300V AC Type 96×96×67.5 H96LV300WG

500V 96×96×67.5 H96LV500WG


Voltmeter 1.5
600V 96×96×67.5 H96LV600WG

500V DC Type 96×96×67.5 H96CV500WG

Frequency meter 1.0 45-55HZ (200V) AC Type 96×96×67.5 H96LHZ01200VWG


METERING

H72 & H96 Panel Meter


Standard: IEC60051

Overall Dimensions

H72 series panel meter

H96 series panel meter


METERING

Electronic Watt-hour Meters


HDDS606 & HDT(S)S606

Product Introduction

Our new generation watt-hour meters are designed and developed to adapt to the reconstruction of power network. They are the
high-tech products manufactured with high quality, intelligent and convenient applications. Our new meters are widely used in high
and low voltage metering cabinets, final distribution metering cabinets, residentials, shopping malls, etc.

New generation includes:


• Single-phase: HDDS606 dial display or LCD display with RS485 and infrared.
• Three-phase: HDT(S)S606 dial display or LCD display with RS485 and infrared.

Online Content

HDDS606 HDTS606

Selection Code

Model Voltage Accuracy Current Frequency Connection Display Mode


Specification

HDDS606 M 1 6M4 6 H C

HDDS606: Single- M: 220V Default: 6M4: 1.5(6)A Default: 50Hz Default: Direct connection Default: Dial display
phase Electronic Watt- N: 230V Class 1 10M4: 2.5(10)A 6: 60Hz (No external CT/VT type) without any optional
Hour Meter 20M4: 5(20)A function
30M6: 5(30)A C: LCD display (485
40M4: 10(40)A interface & infrared)
60M4: 15(60)A
80M4: 20(80)A
100M10: 10(100)A

HDTS606:Three-phase V: 3*230/400V Default: 20M4: 5(20)A Default: 50Hz Default: Direct connection Default: Dial display
Four-wire Electronic Class 1 40M8: 5(40)A 6: 60Hz C: LCD display(485
Watt-Hour Meter 60M12: 5(60)A interface & infrared)
80M4: 20(80)A
100M10: 10(100)A

W: 3*57.7/100V 6M4: 1.5(6)A H: Connect via VT/CT


V: 3*230/400V 6M2: 3(6)A

Note: for HDDS606 the last digit of selection code plus L by default
METERING

Electronic Watt-hour Meters - HDDS606 & HDT(S)S606

Product Features

Smaller & Elegant

• 50% smaller in size to save installation space


• Upgraded appearance design

Accurate Measurement, Safe & Reliable

• Automatic calibration for inspection


• Three lead sealings: factory, verification and installation;
more secure for electricity anti-stealing.

Well Designed, Intelligent & Convenient

• Wider current range, and easier for model selection


• First limit design of bump on the tail cover in our industry, and flip angle
of the tail cover can be more than 135°
• More convenient and firming on wiring.

Qualified Materials & Excellent Performance

• Temperature rise is only 15K, which is far less than national standard 25K.
• Power loss is less than 0.5W.
• Heat deformation temperature reaches to 200ºC.
METERING

Electronic Watt-hour Meters - HDDS606 & HDT(S)S606

Technical Parameters
Energy Meters HDDS606 HDTS606

Connection Method Single phase Three-phase four-wire

Accuracy Class 1

3*57.7/100V (External transformer)


Rated Voltage (V) 220, 230
3*230/400V

3*57.7/100V: 1.5(6)A, 3(6)A

1.5(6)A, 2.5(10)A, 5(20)A,


Current Specification 3*230/400V:
10(40)A, 15(60)A, 10(100)A
1.5(6)A, 3(6)A, 5(20)A, 5(40)A, 5(60)A, 20(80)A,
10(100)A

Display Mode Dial meter or LCD

Deafult functions in LCD Model Infrared communication, RS485 communication

Normal working voltage 0.9~1.1 (Reference voltage)

Ultimate working voltage 0.0~1.15 (Reference voltage)

Rated Voltage 0.75Un~1.15Un

Working Conditions

• Power consumption
Power consumption in voltage circuit: 2W/10VA
Power consumption in current circuit: 4VA

• Temperature range
Range of specified working temperature: -10ºC~+45ºC
Range of ultimate working temperature: -25ºC~+55ºC

• Humidity range
Annual average relative humidity: <75%.
METERING

Electronic Watt-hour Meters - HDDS606 & HDT(S)S606

Nameplate Design

kWh
10000 1000 100 10 1 0.1

HDDS606 1 H2
Pulse Ai
Single-phase Electronic Watt-hour Meter
230V 5(20)A HDDS606 1 H2
Pulse 50Hz 3200imp/kWh Single-phase Electronic Watt-hour Meter

230V 10(100)A
XXX085XXXXXX 50Hz 800imp/kWh
XXX096XXXXXX
IEC 62053-21:2003 2021 IEC 62053-21:2003 2021

HDDS606 - Dial display HDDS606 - LCD display


德力西电气
德力西电气

kWh
10000 1000 100 10 1 0.1

HDTS606 1 H2

Three-phase Four-wire
Electronic Watt-hour Meter Pulse

3×230/400V
3×10(100)A Pulse Ai
50Hz 15 Positive pulse 16 Negative pulse
HDTS606 1 H2
160imp/kWh 1 2 3 4 5 6 7 8 9 10

A
Three-phase Four-wire
B Electronic Watt-hour Meter
C 3×230/400V 11 12 13 14
+
15
-
16 17 18
A
19
B
20
N 10(100)A Active 485

IEC 62053-21:2003 50Hz 1 2 3 4 5 6 7 8 9 10

XXX086XXXXXX 2021 300imp/kWh A


B
C
N

IEC 62053-21:2003
XXX002XXXXXX 2021

德力西电气

德力西电气
HDT(S)S606 - Dial display HDT(S)S606 - LCD display
METERING

Electronic Watt-hour Meters - HDDS606 & HDT(S)S606

Error Limit of Watt-hour Meters

• HDDS606
Error (%)
Load Current Power factor COS
Class 1 Class 2
0.05Ib ≤ I < 0.1Ib 1 ±1.5 ±2.5
0.1Ib ≤ I ≤ Imax 1 ±1.0 ±2.0
0.5L ±1.5 ±2.5
0.1Ib ≤ I < 0.2Ib
0.8C ±1.5 -
0.5L ±1.0 ±2.0
0.2Ib ≤ I ≤ Imax
0.8C ±1.0 -

• HDT(S)S606
Current value Active Power Class 1 Active Power Class 2
Direct connection Through the transformer Power factor COS Error % Power factor COS Error %
0.05Ib ≤ I < 0.1Ib 0.02In ≤ I < 0.05In 1 ±1.5 1 ±2.5
0.1Ib ≤ I ≤ Imax 0.05In ≤ I ≤ Imax 1 ±1.0 1 ±2.0
0.5L ±1.5 0.5L ±2.5
0.1Ib ≤ I < 0.2Ib 0.05In ≤ I < 0.1In
0.8C ±1.5 0.8C ±2.5
0.5L ±1.0 0.5L ±2.0
0.2Ib ≤ I ≤ Imax 0.1In ≤ I ≤ Imax
0.8C ±1.0 0.8C ±2.0

Installation dimensions and Wiring Diagrams


Single-phase

• Overall Dimension
90 51.5
93
112

L in L out
N in N out Pulse 76

• Wiring Diagram

L in L out L in L out
N in N out Pulse
N in N out Pulse

Without communication With communication


METERING

Electronic Watt-hour Meters - HDDS606 & HDT(S)S606

Installation dimensions and Wiring Diagrams

Three-phase
140 61

• Overall Dimension 61
140

160(176) 160(176)
175
175

125

125

Dial Display

68

68

203(219)
218

203(219)
218

130
146

130
146
LCD Display

• Wiring Diagram

15 15 Positive
Positive pulse16 16
pulse Negative
Negative pulse
pulse 15 15 Positive
Positive pulse16 16
pulse Negative
Negative pulse
pulse

1 12 23 3 4 45 56 6 7 78 89 91010 1 21 32 43 54 65 7
6 87 98 910 10

A
A
B
A A
A
B B B B C
C C
C
N
C
N N N N

Wiring diagram of three-phase four-wire external current Wiring diagram of three-phase four-wire external
and voltage transformer connection current transformer connection
(3×57.7/100V 3×1.5(6)A, 3×3(6)A) ( 3×230/400V 3×1.5(6)A, 3×3(6)A)

15 15 Positive
Positive pulse16 16
pulse Negative
Negative pulse
pulse
15 15 Positive
Positive pulse16 16
pulse Negative
Negative pulse
pulse

1 12 23 3 4 45 56 6 7 78 89 91010 1 12 23 3 4 45 56 67 78 89 91010
METERING

Electronic Watt-hour Meters - HDDS606 & HDT(S)S606

Installation dimensions and Wiring Diagrams


Three-phase

• Wiring Diagram

15 Positive pulse 16 Negative pulse

1 2 3 4 5 6 7 8 9 10

A Wiring diagram of three-phase four-wire direct-connection


B
C
N

+ - A B
+ - A B
11 12 13 14 15 16 17 18 19 20 11 12 13 14 15 16 17 18 19 20
Active 485 485
Active
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
HDTS606 three-phase four-wire electronic watt-hour meter
A
connected through the external current and voltage transformer B
15 Positive pulse 16 Negative pulse
A A C
B B
C N
C
N 1 2 3 4 5 6 7 8 9 10 N

A
B
C + - A B + - A B
11 12 13 14 15 16 17 18 19 20 11 12 13 14 15 16 17 18 19 20
Active 485 Active 485
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6+ 7- 8 9 A10 B
10
+ - A B
11 12 13 14 15 16 17 18 19 20 HDTS606 three-phase11 four-wire electronic
12 13 14 15 16 watt-hour
17 18 19meter
20

Active 485 A
(LCD, infrared, and 485) (3×230/400V 3×1.5(6)A,
Active 485

1 2 3 4 5 6 7 8 9 10 B
3×3(6)A),connected 1 2 3the external
through 4 5 6current 7 8transformer
9 10
A C
B
C N
N
A
A
B
A
B
-
B C
C + A B C
11 12 13 14 15 16 17 18 19 20
Active 485

1 2 3 4 5 6 7 8 9 10 HDTS606 three-phase four-wire electronic watt-hour meter


+ - A B (LCD, infrared, and 485) (3×230/400V ,
A 11 12 13 14 15 16 17 18 19 20
direct connection type + - A B
B Active 485
11 12 13 14 15 16 17 18 19 20
C 1 2 3 4 5 6 7 8 9 10 Active 485
N
1 2 3 4 5 6 7 8 9 10

A
A
B
B
C
C
METERING

HLMK Current Transformers


Standard: IEC60044-1

Range Presentation Features Online Content

HLMK Series is Himel range of Current ◆ 100% pure copper varnished wire
Transformer, to measure and transform high ◆ Optimized electric conductivity, less power loss and
current to low current better stability
◆ Shell is made of flame retardant PC material
◆ Maximum rated voltage is 0.66kV
HLMK
Selection Code
Maximum rated Accuracy Rated primary Bus-bar
Range name
voltage class current dimension

HLMK P6 P1 30 30
HLMK P6: 0.66kV Default: class 0.5 30: 30A 30: 30×10mm
P1: class 1 50: 50A 40: 40×10mm
75: 75A 50: 50×15mm
... 60: 60×20mm
5000: 5000A 80: 80×10mm or
60×30mm
100: 100×30mm or
60×40mm
120: 120×25mm or
80×30mm

Rating Table
Busbar diameter (mm) Φ30 Φ40 Φ50 Φ60 Φ80 Φ100 Φ120

600
600
300 500 750
30 750 1500
400 600 800
50 250 800 2000
500 750 1000
Rated primary 75 300 1000 2500
600 800 1200
current to select (A) 100 400 1200 3000
750 1000 1500
150 500 1500 4000
800 1200 2000
200 2000 5000
1000 1500 2500
2500
3000

Technical Parameters
Current Transformers HLMK

Rated primary current 30A-5000A

Rated secondary current 5A

Maximum rated voltage 0.66kV

Accuracy class 0.5, 1.0

Short time thermal current Ith=100Ih

Security coefficient security coefficient FS<5

Standard IEC 60044-1

Certificate CE
METERING

HLMK Current Transformers


Standard: IEC60044-1

HLMK Series Current Transformer provides


◆ Measuring and transforming the high current to low current

Order Information
Accuracy Class: 0.5 Maximum Rated Voltage: 0.66KV

Rated Current Prima- Rated Load Bus-bar Diameter Number of Turns


Model Reference
ry/Secondary (A) (VA) (mm) (mm) through the core
30/5 5-3.75 20 5 HLMKP63030
50/5 5-3.75 20 3 HLMKP65030
75/5 5-3.75 20 2 HLMKP67530
HLMK-0.66-30
100/5 5-3.75 20 2 HLMKP610030
150/5 5-3.75 30×10 20 1 HLMKP615030
200/5 5-3.75 30×10 20 1 HLMKP620030
250/5 5-3.75 40×10 30 1 HLMKP625040
300/5 5-3.75 40×10 30 1 HLMKP630040
HLMK-0.66-40
400/5 5-3.75 40×10 30 1 HLMKP640040
500/5 5-3.75 40×10 30 1 HLMKP650040
300/5 5-3.75 50×15 35 1 HLMKP630050
400/5 5-3.75 50×15 35 1 HLMKP640050
500/5 5-3.75 50×15 35 1 HLMKP650050
HLMK-0.66-50 600/5 10-3.75 50×15 35 1 HLMKP660050
750/5 10-3.75 50×15 35 1 HLMKP675050
800/5 10-3.75 50×15 35 1 HLMKP680050
1000/5 10-3.75 50×15 35 1 HLMKP6100050
500/5 5-3.75 60×20 45 1 HLMKP650060
600/5 10-3.75 60×20 45 1 HLMKP660060
750/5 10-3.75 60×20 45 1 HLMKP675060
HLMK-0.66-60 800/5 10-3.75 60×20 45 1 HLMKP680060
1000/5 10-3.75 60×20 45 1 HLMKP6100060
1200/5 10-3.75 60×20 45 1 HLMKP6120060
1500/5 10-3.75 60×20 45 1 HLMKP6150060
600/5 10-3.75 80×10 or 60×30 50 1 HLMKP660080
750/5 10-3.75 80×10 or 60×30 50 1 HLMKP675080
800/5 10-3.75 80×10 or 60×30 50 1 HLMKP680080
1000/5 10-3.75 80×10 or 60×30 50 1 HLMKP6100080
HLMK-0.66-80
1200/5 10-3.75 80×10 or 60×30 50 1 HLMKP6120080
1500/5 15-3.75 80×10 or 60×30 50 1 HLMKP6150080
2000/5 15-3.75 80×10 or 60×30 50 1 HLMKP6200080
2500/5 15-3.75 80×10 or 60×30 50 1 HLMKP6250080
600/5 10-3.75 100×30 or 60×40 60 1 HLMKP6600100
750/5 10-3.75 100×30 or 60×40 60 1 HLMKP6750100
800/5 10-3.75 100×30 or 60×40 60 1 HLMKP6800100
1000/5 10-3.75 100×30 or 60×40 60 1 HLMKP61000100
HLMK-0.66-100 1200/5 10-3.75 100×30 or 60×40 60 1 HLMKP61200100
1500/5 15-3.75 100×30 or 60×40 60 1 HLMKP61500100
2000/5 15-3.75 100×30 or 60×40 60 1 HLMKP62000100
2500/5 15-3.75 100×30 or 60×40 60 1 HLMKP62500100
3000/5 20-3.75 100×30 or 60×40 60 1 HLMKP63000100
1500/5 15-3.75 120×25 or 80×30 60 1 HLMKP61500120
2000/5 15-3.75 120×25 or 80×30 60 1 HLMKP62000120
2500/5 15-3.75 120×25 or 80×30 60 1 HLMKP62500120
HLMK-0.66-120
3000/5 20-3.75 120×25 or 80×30 60 1 HLMKP63000120
4000/5 20-3.75 120×25 or 80×30 60 1 HLMKP64000120
5000/5 20-3.75 120×25 or 80×30 60 1 HLMKP65000120
METERING

HLMK Current Transformers


Standard: IEC60044-1

Accuracy Class: 1 Maximum Rated Voltage: 0.66KV

Rated Current Primary/ Rated Load Bus-bar Diameter Number of Turns


Model Reference
Secondary (A) (VA) (mm) (mm) through the core
30/5 5-3.75 20 5 HLMKP6P13030
50/5 5-3.75 20 3 HLMKP6P15030
75/5 5-3.75 20 2 HLMKP6P17530
HLMK-0.66-30
100/5 5-3.75 20 2 HLMKP6P110030
150/5 5-3.75 30×10 20 1 HLMKP6P115030
200/5 5-3.75 30×10 20 1 HLMKP6P120030
300/5 5-3.75 30×10 20 1 HLMKP6P130030
250/5 5-3.75 40×10 30 1 HLMKP6P125040
300/5 5-3.75 40×10 30 1 HLMKP6P130040
HLMK-0.66-40
400/5 5-3.75 40×10 30 1 HLMKP6P140040
500/5 5-3.75 40×10 30 1 HLMKP6P150040
600/5 10-3.75 40×10 30 1 HLMKP6P160040
300/5 5-3.75 50×15 35 1 HLMKP6P130050
400/5 5-3.75 50×15 35 1 HLMKP6P140050
500/5 5-3.75 50×15 35 1 HLMKP6P150050
600/5 10-3.75 50×15 35 1 HLMKP6P160050
HLMK-0.66-50
750/5 10-3.75 50×15 35 1 HLMKP6P175050
800/5 10-3.75 50×15 35 1 HLMKP6P180050
1000/5 10-3.75 50×15 35 1 HLMKP6P1100050
1200/5 10-3.75 50×15 35 1 HLMKP6P1120050
500/5 5-3.75 60×20 45 1 HLMKP6P150060
600/5 10-3.75 60×20 45 1 HLMKP6P160060
750/5 10-3.75 60×20 45 1 HLMKP6P175060
800/5 10-3.75 60×20 45 1 HLMKP6P180060
HLMK-0.66-60
1000/5 10-3.75 60×20 45 1 HLMKP6P1100060
1200/5 10-3.75 60×20 45 1 HLMKP6P1120060
1500/5 10-3.75 60×20 45 1 HLMKP6P1150060
2000/5 10-3.75 60×20 45 1 HLMKP6P1200060
600/5 10-3.75 80×10 or 60×30 50 1 HLMKP6P160080
750/5 10-3.75 80×10 or 60×30 50 1 HLMKP6P175080
800/5 10-3.75 80×10 or 60×30 50 1 HLMKP6P180080
1000/5 10-3.75 80×10 or 60×30 50 1 HLMKP6P1100080
HLMK-0.66-80
1200/5 10-3.75 80×10 or 60×30 50 1 HLMKP6P1120080
1500/5 15-3.75 80×10 or 60×30 50 1 HLMKP6P1150080
2000/5 15-3.75 80×10 or 60×30 50 1 HLMKP6P1200080
2500/5 15-3.75 80×10 or 60×30 50 1 HLMKP6P1250080
600/5 10-3.75 100×30 or 60×40 60 1 HLMKP6P1600100
750/5 10-3.75 100×30 or 60×40 60 1 HLMKP6P1750100
800/5 10-3.75 100×30 or 60×40 60 1 HLMKP6P1800100
1000/5 10-3.75 100×30 or 60×40 60 1 HLMKP6P11000100
HLMK-0.66-100 1200/5 10-3.75 100×30 or 60×40 60 1 HLMKP6P11200100
1500/5 15-3.75 100×30 or 60×40 60 1 HLMKP6P11500100
2000/5 15-3.75 100×30 or 60×40 60 1 HLMKP6P12000100
2500/5 15-3.75 100×30 or 60×40 60 1 HLMKP6P12500100
3000/5 20-3.75 100×30 or 60×30 60 1 HLMKP6P13000100
1500/5 15-3.75 120×25 or 80×30 60 1 HLMKP6P11500120
2000/5 15-3.75 120×25 or 80×30 60 1 HLMKP6P12000120
2500/5 15-3.75 120×25 or 80×30 60 1 HLMKP6P12500120
HLMK-0.66-120
3000/5 20-3.75 120×25 or 80×30 60 1 HLMKP6P13000120
4000/5 20-3.75 120×25 or 80×30 60 1 HLMKP6P14000120
5000/5 20-3.75 120×25 or 80×30 60 1 HLMKP6P15000120
METERING

HLMK Current Transformers


Standard: IEC60044-1

Technical Data
Current Transformers HLMK

Rated primary current 30A-5000A

Rated secondary current 5A

Maximum rated voltage 0.66kV

Accuracy class 0.5, 1.0

Short time thermal current Ith=100Ih

Security coefficient security coefficient FS<5

Standard IEC 60044-1

Overall Dimensions

Unit: mm

Model H W D
HLMK-0.66-30 79 60 37

HLMK-0.66-40 99 75 40

HLMK-0.66-50 99 82 40

HLMK-0.66-60 126 102 40

HLMK-0.66-80 118 125 40

HLMK-0.66-100 136 170 40

HLMK-0.66-120 136 190 41


Contact us

Get in touch with Himel Team at Find a Local Himel Distributor at


https://www.himel.com/contact-us https://www.himel.com/find-a-distributor

Reach Himel Global Team at Contact Global Himel Marketing and Communication Team at
support@himel.com sm.himel.communications@himel.com
Visit Himel website at Learn More about Himel's
https://www.himel.com 15-Years of Value Engineering
or Excellence
Scan QR Code ▼ Scan QR Code ▼

©2024 HIMEL

Himel
www.himel.com

MAY 2024

You might also like