Features
6,000 Count LCD Dual display with white backlit.
Auto ranging, terms AC Voltage & Current measurement.
Basic DCV Accuracy of 0.25%.
Highly Linear Readings.
Capacitance Range upto 60mF.
Resistance, Diode and Continuity Measurement Facility
Selectable Frequency & Duty Cycle Measurement.
60 position analogy bar graph for trend indication.
Select, Range, Hold, Rel, Lights, Max/Min
Functions Incorporated.
CE and IEC 61010-1 CAT III (1000V), IP 54 protection.
Robust, Rugged and Double Mould Casing.
M65
Digital Multimeter
CAT III IP Applications
1000V 54 Power Utility Industries
Electrical Contractor
The Motwane M65 Dual display Terms Digital Multimeter with high Telecommunication
accuracy, is specially designed in our Research Laboratory and
Railway
manufactured under stringent manufacturing processes for R&D and
Defence
Process industries. M65 has 6000 count LCD dual display and
measuring facilities like capacitance, resistance, diode and continuity
as well as comes with µ Amp. range & DCV accuracy of 0.25%. M65
includes the features you need to troubleshoot and repair electrical
and electronic systems.
M65 is a high performance multimeter complies with IEC 61010-1
safety standards and with CE, CAT III 1000 V safety rating, meeting
with IP54 protection. M65 is designed very robust and rugged with
double mould casing.
Technical Details M65
Accuracy
Accuracy is valid from 10% of range to 95% of the range.
Accuracy is specified as + % of reading + digits and is valid at 25 + 30C, < 55% RH Humidity.
It is recommended that calibration equipment used to verify the accuracy of the instrument should be 10 times more accurate.
Temp. Coefficient = (0.1% x Specified accuracy) per degree centigrade referred to 25°C. Accuracy is not valid if display shows ' LO BAT'.
General
Display 6,000 Count Dual, LCD display with white backlit.
Display Update Rate 2.8 times per second nominal.
Dimension 94mm(W) X 205 mm(H) X 36 mm (L ) approx.
Weight 450g. approx.
Dual Display For AC Voltage with Frequency & Frequency with Duty Cycle simultaneously
Environmental
Operating Temperature 0°C to 50°C
Relative Humidity 80% RH @ 5°C to 31°C
50% RH @ 31°C to 40°C, Non condensing
Storage Temperature - 20°C to 60°C
Power
Power Supply 9V Battery Type 6F22 or equivalent
Power Consumption 8mA typical.
Low Battery Indication 'LO BAT' is displayed below 6.5V approx.
Auto Power OFF After 15 Min., Ideal sleep mode
consumption is 1.3mA approx. (Can be cancelled by pushing any except for
Hold & SELECT key before power on the meter).
Overload Protection
Fuse Protection for ‘µA’ & ‘mA’ input terminal 0.8 A/ 250V fast blow type ceramic fuse.
Fuse Protection for 10A input terminal 20A/ 500V fast blow type ceramic fuse
V/Ω/ / / /Hz (%) 440 V DC / AC rms
Safety
Directives for CE Certification LVD:2006/95/EC., EMC: 2004/104/EC
Measurement Category CAT III, (1000V) Reinforced Insulation
Relevant Standard Specification EN 61010-1:2010, EN61326-1:2006
IP Rating (Dust & Water Protection) IP 54
Accessories
Standard Accessories
Pair of Test leads, User Manual, Battery installed, Fuses, Carrying Bag.
Technical Details M65
Optional Accessories
Pair of test leads, Pair of small test leads
Range Resolution Max. Reading Accuracy Overload Protection
6V 1 mV 6.000 V +(0.25% + 3)
60V 10 mV 60.00 V +(0.25% + 3)
1050V DC/AC rms
600V 100 mV 600.0 V +(0.25% + 3)
1000V 1V 1000 V +(0.5% + 3)
Note: 1. Input Impedance 10M approx. 2. 600mV Range will be displayed in manual ranging only (Unspecified accuracy).
AC Voltage (50-500Hz) Trms
Range Resolution Max. Reading Accuracy Overload Protection
6V 1 mV 6.000 V +(1% + 5)
60V 10 mV 60.00 V +(1% + 5)
1050V DC/AC rms
600V 100 mV 600.0 V +(1% + 5)
1000V 1V 1000 V +(1.2% + 8)
Note : 1. Input impedance : 10 MΩ approx. shunted by 60pF approx. 2. 600mV Range will be displayed in manual ranging only (Unspecified accuracy).
3. Main display shows AC Voltage & sub display shows frequency applied.
DC Current Range
Range Resolution Max. Reading Accuracy Overload Protection
600µA/6000µA 0.1µA/1µA 600.0µA/6000µA +(1.2% + 5)
0.8A/ 250V DC/AC
fuse protection
60mA/600 mA 10µA/100µA 60.00mA/600.0 mA +(1.5% + 5)
20A/250V DC/AC fuse
10 A 10 mA 10.00 A +(1.5% + 8)
protection
AC Current Range (50Hz-500Hz) Trms
Range Resolution Max. Reading Accuracy Overload Protection
600µA/6000µA 0.1µA/1µA 600.0µA/6000µA +(1.5% + 5)
0.8A/ 250V DC/AC fuse
protection
60mA/600 mA 10µA/100µA 60.00mA/600.0 mA +(1.8% + 5)
20A/250V DC/AC fuse
10 A 10 mA 10.00 A +(2.0% + 8)
protection
Note: Main display shows AC Current and sub display shows frequency applied.
Resistance Range
Range Resolution Max. Reading Accuracy Overload Protection
600 Ω 0.1 Ω 600.0 Ω +(0.5% + 3)
6 KΩ 1Ω 6.000 Ω +(0.5% + 3)
60 KΩ 10 Ω 60.00 KΩ +(0.5% + 3)
440V DC/AC rms
600 KΩ 100 Ω 600.0 KΩ +(0.5% + 3)
6 MΩ 1 KΩ 6.000 MΩ +(1% + 5)
60 MΩ 10 KΩ 60.00 MΩ +(3% + 10)
Note : 1. Open Circuit voltage on 600Ω range is -3.3V DC approx. 2. Open Circuit voltage on 6kΩ-6MΩ ranges is -1.10V DC approx.
3. Open Circuit Voltage on 60MΩ range is -600mV approx.
Technical Details M65
Capacitance Range (Auto Ranging Only)
Pair of test leads, Pair of small test leads
Range Resolution Max. Reading Accuracy Overload Protection
6 nF 0.001 nF 6.000 nF +(5.0% + 10)
60 nF 0.01 nF 60.00 nF +(3.0% + 10)
600 nF 0.1 nF 600.0 nF +(3.0% + 10)
6 µF 1 nF 6.000 µF +(3.0% + 10)
440V DC/AC rms
60 µF 10 nF 60.00 µF +(3.0% + 10)
600 µF 100 nF 600.0 µF +(5.0% + 10)
6 mF 1 µF 6.000 mF +(5.0% + 20)
60 mF 10 µF 60.00 mF +(5.0% + 30)
Note : 1. Settling time on 6mF and 60mF range is 40 sec. approx. 2. Press REL button at 6nF & 60nF ranges so that the offset count can be subtracted
from measurement. Now apply low value capacitance.
Diode Test
Range Resolution Open Circuit Voltage Test Current
6V 1mV <3.0 V DC approx. <2.0mA approx.
Continuity Test
Range Resolution
600.0Ω 0.1Ω Meter Beeps < 60Ω
Note: Open Circuit Voltage on continuity range is -3.3VDC approx.
Frequency Ranges (Auto Ranging Only)
Range Resolution Max. Reading Accuracy Overload Protection
60 Hz 0.01 Hz 60.00 Hz +(0.5% + 3)
600 Hz 0.1 Hz 600.0 Hz +(0.5% + 3)
6 KHz 1 HZ 6.000 KHz +(0.5% + 3)
60 KHz 10 Hz 60.00 KHz +(0.5% + 3) 1000V DC/AC rms
600 KHz 100 Hz 600.0 KHz +(0.5% + 3)
6 MHz 1 KHz 6.000 MHz +(0.5% + 3)
60 MHz 10 KHz 60.00 MHz +(0.5% + 3)
Note: 1. Main display shows frequency & sub display shows Duty Cycle. 2. If input frequency is less than 6.0Hz, display will show 0.00Hz.
Duty Cycle Measurement
Range Resolution Open Circuit Voltage Test Current
0.1%-98.9% 0.1% +(0.5% + 30) 440V DC/AC rms
Accuracy is specified at <20 VAC rms Sensitivity : 10Hz to 100 KHz > 200mVrms, 1000 KHz to 10MHz > 2Vrms
Electromagnetic compatibility: In RF Field, overall accuracy is equal to 10% of reading +30 digits
Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.