TRMS DIGITAL MULTIMETER THINK SAFETY

THINK
An ISO 9001:2015 Company MODEL-KM 60-T
FEATURES :
í Backlight Display í Pulse Output í Data Hold
NEW
í Non-Contact Voltage Measurement (NCV) í Flash Light í MAX / MIN & Rel Zero

GENERAL SPECIFICATIONS

í Sensing : True RMS í Automatic Polarity display.


í Display : 3-5/6 digits 6000 counts liquid í Auto Power Off :
crystal LCD display about 15 minutes when no signal.
í Maximum Display : 5999 counts
í Low Battery Indication : Below 2.3V
í Sampling Time : about 3 times / second
í Power Supply : 1.5V AAA x 2 battery.
í Operating Temperature : 0°C to 40°C,
í Dimension :
Relative Humidity <80%
Approx.142(L)mm x 70(W)mm x 32(H)mm
í Measurement : Double integral A/D conversion.
í Overrange Display : ‘OL’ í Weight : Approx. 205gm (including battery).

˜ ACCESSORIES : Test leads (pair), Battery & User Manual.

SAFETY
˜ Safety : Complies with the safety requirements IEC1010 CAT III 600V. Preliminary Data

ELECTRICAL SPECIFICATIONS : KM 60-T

Accuracy is ± (% reading digits + number of digits) or otherwise specified @ 23°C ± 5°C & less than 75% R.H.

DC VOLTAGE AC VOLTAGE
Range Resolution Accuracy Range Resolution Accuracy
6 V 0.001 V 6 V 0.001 V
60 V 0.01 V ±(0.5%rdg + 3dgts) 60 V 0.01 V ±(0.8%rdg + 3dgts)
600 V 0.1 V 600 V 0.1 V
1000 V 1 V ±(0.8%rdg + 10dgts) 750 V 1 V ±(1.2%rdg + 10dgts)
Input Impedance : 10MW Input Impedance : 10MW
Overload Protection : 6V range is 550V DC or AC peak; Standard sine wave & triangular wave frequency response is 40Hz ~ 1kHz.
The rest is 1000V DC or 750V AC Peak. Other waveforms are : 40Hz ~ 200Hz.
Maximum input voltage : 750V AC (RMS) or 1000V DC

DC CURRENT DC CURRENT (mA)


Range Resolution Accuracy Range Resolution Accuracy
60 mA 10 mA 600 mA 0.1 mA
±(1.2%rdg + 10dgts) ±(1.2%rdg + 10dgts)
600 mA 100 mA 6000 mA 1 mA

The Maximum measured pressure drop : 600mV The Maximum measured pressure drop : 600mV
Overload Protection : 60mA / 600mA : 600mA/250V Speed Glass Fuse. Overload Protection : 600mA / 6000mA : 600mA/250V Speed Glass Fuse.

AC CURRENT AC CURRENT (mA)


Range Resolution Accuracy Range Resolution Accuracy
60 mA 10 mA 600 mA 0.1 mA
±(1.2%rdg + 10dgts) ±(1.2%rdg + 10dgts)
600 mA 100 mA 6000 mA 1 mA

The Maximum measured pressure drop : 600mV The Maximum measured pressure drop : 600mV
Overload Protection : 60mA / 600mA : 600mA/250V Speed Glass Fuse. Overload Protection :
600mA / 6000mA : 600mA/250V Speed Glass Fuse.

All Specifications are subject to change without prior notice.

Chhaya common data/chhaya/my documents/chhaya/backup/catlog/New catlog/2020/KM 60-T/108B.cdr


ELECTRICAL SPECIFICATIONS : KM 60-T

FREQUENCY CAPACITANCE
Range Resolution Accuracy Range Resolution Accuracy
10 Hz 0.01 Hz 60 nF 10 pF
100 Hz 0.1 Hz 600 nF 100 pF
1 kHz 1 Hz 6 mF 1 nF ±(3.5%rdg + 20dgts)
10 kHz 10 Hz ±(0.1%rdg + 3dgts) 60 mF 10 nF
100 kHz 100 Hz 600 mF 100 nF
1 MHz 1 kHz 6 mF 11 mF
±(5.0%rdg + 3dgts)
10 MHz 10 kHz 30 mF 10 mF
Overload Protection : 550V DC or AC peak (less than 10 seconds) Overload Protection : 550V DC or AC peak
Input Voltage Range : 1V rms

RESISTANCE DIODE & CONTINUITY TEST


Range Resolution Accuracy Range Display Value Test condition
600 W 0.1 W ±(0.8%rdg + 5dgts) Diode forward Positive DC Current of about
6 kW voltage drop 1mA, open circuit voltage of
1 W W
about 3V.
60 kW 10 W
±(0.8%rdg + 3dgts) The buzzer buzzes Open circuit voltage is
600 kW 100 W
for a long time, & the about 3V press “SELECT” to
6 MW 1 kW test resistance is less
switch between two functions.
40 MW 10 kW ±(2.5%rdg + 3dgts) than (50 ± 20)W.

Open Circuit Voltage : Less than 3V Overload Protection : 550V DC or AC peak.


Overload Protection : 550V DC or AC Peak

STRAIGHT 10A CURRENT (DC/AC)


Range Resolution Accuracy
6 A 0.01 A
±(2.0%rdg + 30dgts)
10 A 0.01 A

The Maximum measured pressure drop : 600mV


Overload Protection : 60mA / 600mA : 600mA/250V Speed Glass Fuse.
All Specifications are subject to change without prior notice

® G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022-24156638, 27754546 Tel. :24124540, 24181649, 27750662, 27750292
An ISO 9001:2015 Company Email : sales@kusam-meco.co.in Website : www.kusamelectrical.com

Chhaya common data/chhaya/my documents/chhaya/backup/catlog/New catlog/2020/KM 60-T/108B.cdr

You might also like