Urb LD-30WR3
Urb LD-30WR3
URA_LD-30WR3 & URB_LD-30WR3 series of isolated 30W DC-DC converter products with an ultra-wide 4:1 input voltage and feature
efficiencies of up to 90%, input to output isolation is tested with 1500VDC and the converters safely operate ambient temperature of -40℃
to +80℃, input under-voltage protection, output short-circuit, over-voltage, over-current protection. They meet CLASS A of
CISPR32/EN55032 EMI standards without external components, optional packages are offered for chassis or DIN-rail mounting (A2S, A4S),
adding additional input reverse polarity protection and they are widely used in applications such as data transmission device, battery
power supply device, telecommunication device, distributed power supply system, hybrid module system, remote control system, industrial
robot and railway fields.
Selection Guide
Input Voltage (VDC) Output Full Load Capacitive
Certification Part No. Efficiency Load
① ④ ⑤
Nominal Current (mA)
②
2022.08.01-B/6 Page 1 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
②The minimum input voltage and starting voltage of A2S and A4S Model are 1VDC higher than those of DIP package due to input reverse polarity protection
function;
③Exceeding the maximum input voltage may cause permanent damage;
④Efficiency is measured at nominal input voltage and rated output load; efficiencies for A2S and A4S Model’s is decreased by 2% due to the input reverse
polarity protection circuit;
⑤The specified maximum capacitive load for positive and negative output is identical.
Input Specifications
Item Operating Conditions Min. Typ. Max. Unit
3.3V output -- 971/60 994/100
24VDC nominal input series,
5V output -- 1453/60 1488/100
nominal input voltage
Input Current (full load / Others -- 1420/6 1488/16
no-load) 3.3V output -- 480/20 491/30 mA
48VDC nominal input series,
5V output -- 718/20 735/35
nominal input voltage
Others -- 710/5 744/10
Reflected Ripple Current Nominal input voltage -- 40 --
24VDC nominal input series -0.7 -- 50
Surge Voltage (1sec. max.)
48VDC nominal input series -0.7 -- 100
24VDC nominal input series -- -- 9
Start-up Voltage VDC
48VDC nominal input series -- -- 18
24VDC nominal input series 5.5 6.5 --
Input Under-voltage Protection
48VDC nominal input series 12.0 15.5 --
Start-up Time Nominal input voltage & constant resistance load -- 10 -- ms
Input Filter Pi filter
Hot Plug Unavailable
Output Specifications
Item Operating Conditions Min. Typ. Max. Unit
5%-100% load -- ±1 ±3
Voltage Accuracy
0%-5% load -- ±1 ±5
2022.08.01-B/6 Page 2 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Note:
①Load regulation for 0%-100% load is ±5%;
②The “parallel cable” method is used for ripple and noise test, please refer to DC-DC Converter Application Notes for specific information.
General Specifications
Item Operating Conditions Min. Typ. Max. Unit
Input-output Electric Strength test for 1 minute with a
Isolation 1500 -- -- VDC
leakage current of 1mA max.
Insulation Resistance Input-output resistance at 500VDC/60sec 1000 -- -- MΩ
Isolation Capacitance Input-output capacitance at 100kHz/0.1V -- 2000 -- pF
Operating Temperature See Fig. 1, Fig. 2, Fig. 3 and Fig. 4 -40 -- +80
℃
Storage Temperature -55 -- +125
Storage Humidity Non-condensing 5 -- 95 %RH
Pin Soldering Resistance
Soldering spot is 1.5mm away from case for 10 seconds -- -- +300 ℃
Temperature
Vibration IEC/EN61373 - Category 1, Grade B
Switching Frequency * PWM mode -- 300 -- kHz
MTBF MIL-HDBK-217F@25℃ 1000 -- -- k hours
Note:* Switching frequency is measured at full load. The module reduces the switching frequency for light load (below 50%) efficiency improvement.
Mechanical Specifications
Case Material Aluminum alloy
Horizontal package (without heat sink) 50.80 × 25.40 × 11.80 mm
Horizontal package (with heat sink) 51.40 × 26.20 × 16.50 mm
A2S chassis mounting (without heat sink) 76.00 × 31.50 × 21.20 mm
Dimensions
A2S chassis mounting (with heat sink) 76.00 × 31.50 × 25.30 mm
A4S Din-rail mounting (without heat sink) 76.00 × 31.50 × 25.80 mm
A4S Din-rail mounting (with heat sink) 76.00 × 31.50 × 29.90 mm
Without heat sink Horizontal package/A2S chassis mounting/A4S Din-rail mounting 27.8g/52.0g/72.0g(Typ.)
Weight
With heat sink Horizontal package/A2S chassis mounting/A4S Din-rail mounting 37.0g/60.0g/80.0g(Typ.)
Cooling Method Free air convection
2022.08.01-B/6 Page 3 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Fig. 1 Fig. 2
Applicable models: URA2405LD-30W(H)R3 (9-18V input voltage), Applicable models: URA2405LD-30W(H)R3 (18-36V input voltage),
URA2424LD-30W(H)R3 (9-18V input voltage), URA2424LD-30W(H)R3 (18-36V input voltage),
URA4805LD-30W(H)R3 (18-36V input voltage) URA4805LD-30W(H)R3 (36-75V input voltage),
URA2412LD-30W(H)R3, URA2415LD-30W(H)R3,
URA4812LD-30W(H)R3, URA4815LD-30W(H)R3
Fig. 3 Fig. 4
Applicable models: URB2403LD-30W(H)R3, URB2405LD-30W(H)R3, Applicable models: URB2409LD-30W(H)R3, URB2412LD-30W(H)R3,
URB4803LD-30W(H)R3, URB4805LD-30W(H)R3 URB2415LD-30W(H)R3, URB2424LD-30W(H)R3,
URB4812LD-30W(H)R3, URB4815LD-30W(H)R3,
URB4824LD-30W(H)R3
2022.08.01-B/6 Page 4 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Design Reference
1. Typical application
All the DC/DC converters of this series are tested before delivery using the recommended circuit shown in Fig. 5.
Input and/or output ripple can be further reduced by appropriately increasing the input & output capacitor values Cin and Cout and/or by
selecting capacitors with a low ESR (equivalent series resistance). Also make sure that the capacitance is not exceeding the specified max.
capacitive load value of the product.
Dual
Vin +Vo
Cout
Cin DC DC 0V Single output Dual output
Cout Cin Cout Cin
Cout voltage voltage
GND (µF) (µF) (µF) (µF)
-Vo (VDC) (VDC)
Single 3.3/5/9 220 ±5/±12/±15 220
100 100
Vin +Vo 12/15/24 100 ±24 100
Cin DC DC Cout
GND 0V
Fig. 5
2. EMC compliance circuit
Parameter description:
Model Vin:24VDC Vin:48VDC
Choose according to actual input
FUSE
Single output: current
MOV S20K30 S14K60
C0 680µF/50V 330µF/100V
C1 330µF/50V 330µF/100V
C2 4.7µF/50V 2.2µF/100V
C3 Refer to the Cout in Fig.5
1mH, recommended to use
LCM
MORNSUN’s FL2D-30-102
Fig. 6 CY1/CY2 1nF/2kV
Notes: We use Part ① in Fig. 6 for immunity and part ② for emissions test.
Selecting based on needs.
2022.08.01-B/6 Page 5 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Notes: We use Part ① in Fig. 7 for immunity and part ② for emissions test. LDM1 3.3µH
Selecting based on needs. CY1/CY2 2.2nF/400VAC Safety Y Capacitor
aR 2 Vref
R1 up: R T = -R 3 a= R1
R3 R1 RT R 2 -a Vo’-Vref
V r ef Trim R3
V r ef Trim aR 1 Vo’-Vref
R2
down : R T = -R 3 a= R2
RT R 1 -a Vref
R2
2022.08.01-B/6 Page 6 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
2022.08.01-B/6 Page 7 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
2022.08.01-B/6 Page 8 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
2022.08.01-B/6 Page 9 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Notes:
1. For additional information on Product Packaging please refer to www.mornsun-power.com. Horizontal Packaging Bag Number:
58200035(without heat sink), 58200051(with heat sink), A2S/A4S Packaging Bag Number: 58220022;
2. The maximum capacitive load offered were tested at input voltage range and full load;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75%RH with nominal
input voltage and rated output load;
4. All index testing methods in this datasheet are based on company corporate standards;
5. We can provide product customization service, please contact our technicians directly for specific information;
6. Products are related to laws and regulations: see "Features" and "EMC";
7. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by
qualified units.
2022.08.01-B/6 Page 10 of 10
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation