100W Single Output Switching Power Supply RS-100 series

User’s Manual
■ Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105℃ long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70℃
Withstand 5G vibration test
■ GTIN CODE High efficiency, long life and high reliability
MW Search: https://www.meanwell.com/serviceGTIN.aspx
3 years warranty Bauar t gepruft
Sicherheit
egel ma ge
od o s
be wac g

SPECIFICATION
www. tuv.com
ID 2000000000

AS/NZS62368-1 UL62368-1 BS EN/EN62368-1 IEC62368-1 TPTC004

MODEL RS-100-3.3 RS-100-5 RS-100-12 RS-100-15 RS-100-24 RS-100-48


DC VOLTAGE 3.3V 5V 12V 15V 24V 48V
RATED CURRENT 20A 16A 8.5A 7A 4.5A 2.3A
CURRENT RANGE 0 ~ 20A 0 ~ 16A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.3A
RATED POWER 66W 80W 102W 105W 108W 110.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
OUTPUT VOLTAGE ADJ. RANGE 3.2V ~ 3.5V 4.75 ~ 5.5V 11.4 ~ 13.2V 14.25 ~ 16.5V 22.8 ~ 26.4V 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION Note.5 ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 95ms/230VAC 17ms/115VAC at full load
VOLTAGE RANGE 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 74% 77% 81% 82% 84% 84%
INPUT
AC CURRENT (Typ.) 2.5A/115VAC 1.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP. -25 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
(Note 6) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
MTBF 3196.6K hrs min. Telcordia SR-332 (Bellcore) ; 526.7K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 159*97*38mm (L*W*H)
PACKING 0.6Kg; 24pcs/15.4Kg/0.83CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
NOTE
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:RS-100-SPEC 2024-02-23


100W Single Output Switching Power Supply RS-100 series

Mechanical Specification Case No. 901C Unit:mm

152.5

7
3.5
1

2
9.5

65

84.5
97
8.2

5
3
6 2-M

.5
ψ3
4.5
24 78
159

6.5 150
9

Terminal Pin No. Assignment


9
18.5
ψ3

Pin No. Assignment Pin No. Assignment


3.5

3-
38
18

M3
.5

1 AC/L 4,5 DC OUTPUT -V


28.5

2 AC/N 6,7 DC OUTPUT +V


3 FG
22 117

Block Diagram fosc : 60KHz

EMI RECTIFIERS POWER RECTIFIERS +V


I/P FILTER & SWITCHING &
-V
FILTER FILTER

DETECTION
FG
CIRCUIT
O.L.P. CONTROL
O.V.P.

Derating Curve Static Characteristics

100
100
Others
90
80
80

60 3.3V,5V 70
LOAD (%)

LOAD (%)

60
40
50
20
40

-25 0 10 20 30 40 50 60 70 (HORIZONTAL) 88 95 100 115 120 140 160 180 200 220 240 264
-25 0

AMBIENT TEMPERATURE (℃) INPUT VOLTAGE (VAC) 60Hz

File Name:RS-100-SPEC 2024-02-23