10W Single Output Switching Power Supply                                                                                                                                                   S- 10   series
■ Features :
                                                                                                                                 · Universal AC input/Full range
                                                                                                                                 · Protections:Short circuit/Over load/Over voltage/Over temperature
                                                                                                                                 · Cooling by free air convection
                                                                                                                                 · 100% full load burn-in test
                                                                                                                                 · Fixed switching frequency at 67KHz
                                                                                                                                 · 1 year warranty
SPECIFICATION
                      MODEL                                   S-10-5                                               S-10-12                                                 S-10-24
              DC VOLTAGE                                      5V                                                   12V                                                     24V
              RATED CURRENT                                   2A                                                   0.83A                                                   0.41A
              CURRENT RANGE                                   0 ~ 2A                                               0 ~0.83A                                                0 ~ 0.41A
              RATED POWER                                     10W                                                  10W                                                     10W
              RIPPLE & NOISE (max.) Note.2                    150mVp-p                                             150mVp-p                                                200mVp-p
 OUTPUT       VOLTAGE ADJ. RANGE                              4.75 ~ 5.5V                                          10.8 ~ 13.2V                                            22.6 ~ 26.4V
              VOLTAGE TOLERANCE Note.3                        ±2.0%                                                ±1.0%                                                   ±1.0%
              LINE REGULATION                                 ±1.5%                                                ±0.5%                                                   ±0.5%
              LOAD REGULATION                                 ±1.5%                                                ±0.5%                                                   ±0.5%
              SETUP, RISE                                     1000ms, 30ms/230VAC                 1000ms, 30ms/115VAC at full load
              HOLD TIME (Typ.)                                100ms/230VAC                 20ms/115VAC at full load
              VOLTAGE RANGE                                   85 ~ 264VAC                120 ~ 370VDC
              FREQUENCY RANGE                                 47 ~ 63Hz
              EFFICIENCY (Typ.)                               78%                                                  81%                                                     84%
  INPUT
              AC CURRENT                                      0.35A/115VAC                0.25A/230VAC
              INRUSH CURRENT (max.)                           COLD START 20A
              LEAKAGE CURRENT                                 <2mA / 240VAC
                                                              Above 105% rated output power
                            OVER LOAD
                                                              Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION               OVER VOLTAGE
                                                              Protection type : Shut down o/p voltage, re-power on to recover
                                                              U1 Tj 140℃ typically (U1) Detect on main control IC
                     OVER TEMPERATURE
                                                              Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
              WORKING TEMP.                                   -20 ~ +60 ℃(Refer to output load derating curve)
              WORKING HUMIDITY                                20 ~ 90% RH non-condensing
ENVIRONMENT   STORAGE TEMP., HUMIDITY                         -20 ~ +85℃ , 10 ~ 95% RH
              TEMP. COEFFICIENT                               ±0.03%/ ℃(0 ~ 50℃ )
              VIBRATION                                       10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
              SAFETY STANDARDS                                UL60950-1, CB(IEC60950-1) Approved
              WITHSTAND VOLTAGE      I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE        I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
   EMC
 (Note 6) EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
              HARMONIC CURRENT                                Compliance to EN61000-3-2,-3
              EMS IMMUNITY                                    Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A
              MTBF                                            390Khrs min.         MIL-HDBK-217F (25℃ )
 OTHERS       DIMENSION                                       70*40*30mm (L*W*H)
              PACKING
              1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
              2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
              3. Tolerance : includes set up tolerance, line regulation and load regulation.
  NOTE
              4. Line regulation is measured from low line to high line at rated load.
              5. Load regulation is measured from 0% to 100% rated load.
              6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.