SA-P

Sta inl ess ste el cap tiv e


- Zone 1, 2, 21, 22 scr ews
- Polyester junction boxes Me tal pla tes riv ete d
- Choice of 9 sizes ont o lid
- With antistatic property
- IK10 mechanical strength
- IP66

En closur e moun tin g


feet

D.169 ED.2022
SA-P series junction boxes: criteria for choosing the right product

When it comes to deciding on an increased safety enclosure, there is a whole series of essential data to be
taken into account if you are to make the right choice: the mechanical strength of the materials, corrosion
resistance, the IP protection rating and IK impact protection rating in the case of enclosures for watertight/
industrial use.

Mechanical strength

Properties Unit Stainless steel Aluminium Polyester

Density g/cm3 8,0 2,65 1,7

Tensile strength Mpa 500-700 80-110 130

Elongation % 60-40 4-10 2

Modulus of elasticity Gpa 193 79 11

Yield strength Mpa ≥ 200 80-165 -

Coeff. of thermal expansion (20-100°C) 10-6K-1 16 21 -

Resistivity Ωm 7,5x10-7 4,8x10-8 -

Electrical conductivity Ω-1m-1 1,33x106 2,08x107 -

The graph below gives an overview of what use the various materials are suitable for based on the mechanical
stress and harshness of the environmental conditions likely to be encountered.
High
Mechanical strength

Stainless steel
Aluminium

Polyester

Low
Corrosion resistance (suitability for outdoor use)

ED.2022 D.170
Protection ratings

IP PROTECTION RATINGS (IEC 529, EN 60529-4, CEI 70-1 ed. 11/92)


The table gives protection ratings in accordance with standard CEI 70-1 ed. 11/92. Ratings are identified by the acronym
IP followed by 2 digits, to which 2 letters may be added, indicating the degree to which persons are protected against
access or other properties There is some variation in the application of ratings 7 and 8 relating to the ingress of liquids, with
these ratings not always meaning that the item is suitable for lower levels (whereas IP rating x4 also covers the lower levels).
IMPACT PROTECTION RATINGS
This classification shows the acceptable level of strength, when evaluating a product's safety, and is mainly employed in
relation to testing on electromechanical products.

1ST DIGIT 2ND DIGIT PROTECTION AGAINST EXTERNAL


PROTECTION AGAINST SOLID OBJECTS PROTECTION AGAINST MOISTURE MECHANICAL IMPACT *

0 Not protected
0 Not protected IK00
Not protected

1
Protected against
solid objects
greater than 1
Protected against
vertically falling
IK01 0.25 kg
5.6 cm
drops of water Protected against im-
50mm in Ø
pact energy of 0.15J

IK03
Protected against 0.25 kg

2 2
Protected against 14 cm
solid objects
rain when tilted up
greater than
to 15° Protected against im-
12mm in Ø
pact energy of 0.35J

3
Protected against
solid objects
greater than 3
Protected against
rain when tilted up
IK05 0.25 kg
28 cm
to 60° Protected against
2.5mm in Ø impact energy of 0.7J

IK06
Protected against 0.25 kg

4 4
Protected 40 cm
solid objects
against splash-
greater than 1mm
ing water Protected against
in Ø
impact energy of 1J

5 Protected against
dust 5
Protected against
jets of water from
IK07 0.5 kg
40 cm
all directions Protected against
impact energy of 2J

6
Totally protected
against the ingress
6 Protected against
heavy seas
IK08 1.7 kg
30 cm
of dust Protected against
impact energy of 5J

A
ADDITIONAL LETTER**
Protected against access with the back
of the hand 7
Protected against
the effects of im-
IK09 5 kg
20 cm
mersion Protected against

B Protected against access with a finger impact energy of 10J

C Protected against access with a tool IK10 5 kg

8
Protected against 40 cm
the effects of con-
D Protected against access with a wire tinuous immersion Protected against
impact energy of 20J

OPTIONAL LETTER

H High-voltage device * As per IEC EN 50102: 1996-05; IEC EN 60078-2-7-5: 1998-09.

M Tested against the harmful effects of water


ingress with the equipment running ** Optional letter describing protection against access by per-
sons. Only used if protection against access to hazardous
S Tested against the harmful effects of water ingress
with the equipment not running parts is greater than that indicated by the first digit, or if only
protection against access to hazardous parts is given and an
W Suitable for use in specified atmos-
pheric conditions X is used in place of the first digit.

D.171 ED.2022
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

SA...P series junction boxes are made from fibreglass-reinforced polyester. Because they are highly resistant to
contamination from fuel oils and mechanical shock, in addition to being lightweight and practical, they can be installed
in all industrial plants, especially those where there is a potential risk of explosion and/or fire due to the presence of
combustible gases or dust, classified as Zone 1, 2, 21 and 22. The enclosures have special holes made in the base for
easy wall mounting. The lid features a silicone gasket that is resistant to low and high temperatures and comes complete
with AISI 304 stainless steel screws, which are arranged around the outside of the lid to ensure a tight seal with the
IP66 rating. SA...P series enclosures are mainly used as junction boxes/for routing cables for analogue or digital
signals and/or for control and monitoring associated with equipment such as motors, fans, pumps and/or for giving
physical readings such as flow rate, level, pressure, temperature, current, etc.. Terminal strips can be arranged inside
the enclosure in various different configurations. The Cortem sales team will be able to advise you what enclosure best
meets your needs based on: maximum number of terminals, number of holes per side, minimum distance involved and
maximum power dissipation, ensuring everything is within the limits allowed by the certificate. 'Ex e' control, monitoring
and signalling devices can be mounted on the lid in various different configurations based on your requirements and
within the limits allowed by the certificate.

Cortem Group labels its products with a non-removable adhesive label featuring a hologram and
an alphanumerical univocal code, as a safety measure against the illegal sale of fakes so that
all the products are guaranteed as original. Non-compliance with the International standards
entails serious risks for the environment, especially for those working daily on the plants.

TYPE AND APPLICATION


Choosing an appropriate container is a key step in the project development process, making it essential to approach
the decision systematically, evaluating all variables methodically: where our equipment is being installed, the environmental conditions
on site, what degree of protection it must have, what space is available and how it is due to be set up. Once you have processed all
this information, you should be able to determine which product best suits the design requirements in question.
ENVIRONMENTAL CONDITIONS
The first factor to consider is what environmental conditions the equipment is going to be installed in, whether it will be indoors or
outside, and what environments it is required to operate in: pharmaceutical, chemical, petrochemical, food, shipbuilding, agricultural
industries...
DIMENSIONS
The size of the space available for inserting the enclosure and its components must be determined early on in the process.
DESIGN
Taking into account the technical aspect, product design and appearance is also important in ensuring the equipment to be installed
in the enclosure is integrated seamlessly. A Cortem team of experts is on hand every day to address your questions and come up
with the best solutions.
Cortem enclosures have passed:
- IP protection testing;
- IK strength testing;
- salt mist testing for corrosion resistance;
- heat resistance testing;
- low temperature resistance testing.

Application sectors:
Oil refineries Chemical and Onshore Offshore Low Fuel Ships and Wastewater
petrochemical plants plants temperatures depots shipbuilding treatment
plants

ED.2022 D.172
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

CERTIFICATION DATA FOR ENCLOSURES WITH TERMINALS

Classification: Group II Category 2GD

Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust)

Marking: II 2GD Ex eb IIC T6/T5/T4 Gb - Ex tb IIIC T75°C/T110°C Db IP66

II 2GD Ex e ia IIC T6/T5/T4 Gb - Ex ia IIIC T75°C/T110°C Db IP66

II 2GD Ex eb ia IIC T6/T5/T4 Gb - Ex ia tb IIIC T75°C/T110°C Db IP66

Certification: ATEX CESI 03 ATEX 333

IEC Ex CES 13.0001

ECASEx AVAILABLE All IEC Ex, ECASEx, TR CU and INMETRO


certification
data can be downloaded from
TR CU AVAILABLE www.cortemgroup.com

INMETRO DNV 15.0119


CENELEC EN 60079-0: 2018, EN 60079-7: 2015, EN 60079-11: 2012, EN 60079-31: 2014 and
Standards: EUROPEAN DIRECTIVE 2014/34/UE
IEC 60079-0: 2017, IEC 60079-7: 2015, IEC 60079-11: 2011, IEC 60079-31: 2013

Ambient Temp.: See "ambient temperature range" table

Degree of protection: IP66

AMBIENT TEMPERATURE RANGE

MAXIMUM SURFACE MAXIMUM TERMINAL


AMBIENT TEMPERATURE TEMPERATURE CLASS
TEMPERATURE OPERATING TEMPERATURE
-40°C +40°C T6 T75°C +80°C
-40°C +55°C T5 T75°C +95°C

HIGH TEMPERATURE RANGE


(accordingly with the temperature allowed by the terminals)
MAXIMUM SURFACE MAXIMUM TERMINAL
AMBIENT TEMPERATURE TEMPERATURE CLASS
TEMPERATURE OPERATING TEMPERATURE
-40°C +65°C** T5 T75°C +95°C

** For this temperature range the maximum dissipated power shall be reduced by 25% and the nominal current by 15%

D.173 ED.2022
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

CERTIFICATION DATA OF ENCLOSURES FOR CONTROL, MONITORING AND SIGNALLING UNITS

Classification: Group II Category 2GD

Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust)

Marking: II2GD - Ex db eb IIC T6/T5 Gb - Ex tb IIIC T85°C/T100°C Db - IP66

II2GD - Ex eb IIC T6/T5 Gb - Ex tb IIIC T85°C/T100°C Db - IP66


(When on the box is installed only ammeter or voltmeter type B-0140)

Certification: ATEX CESI 03 ATEX 115 X

IEC Ex CES 11.0032 X

ECASEx AVAILABLE All IEC Ex, ECASEx, TR CU and INMETRO


certification
data can be downloaded from
TR CU AVAILABLE www.cortemgroup.com

INMETRO DNV 15.0125

CENELEC EN 60079-0: 2018, EN 60079-1: 2014, EN 60079-7: 2015, EN 60079-11: 2012, EN 60079-
18: 20150 EN 60079-31: 2014, EN 60529: 1991 and EUROPEAN DIRECTIVE 2014/34/UE
Standards: IEC 60079-0: 2017, IEC 60079-1: 2014, IEC 60079-7: 2015, IEC 60079-11: 2011, IEC 60079-18:
2014, IEC 60079-31:2013, IEC 60529: 2001

With temperature class T6 and maximum


Ambient Temp.: -40°C +40°C surface temperature T85°C.

With temperature class T5 and maximum


-40°C +55°C surface temperature T100°C.

Degree of protection: IP66

CERTIFICATION DATA OF ENCLOSURES WITH EQUIPMENT (FIELDBUS, PROXIMITOR, HEATER...)

Classification: Group II Category 2GD

Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust)

Marking: II2GD - Ex eb IIC T6/T5 Gb - Ex tb IIIC T85°C/T100°C Db - IP66

II2(1)GD - Ex eb ib mb [ia Ga] IIC T4 Gb - Ex tb [ia Da] IIIC T85°C Db IP66

Certification: ATEX CML 16 ATEX 3163X


All IEC Ex certification data can be downloaded
IEC Ex CML 16.0074X from www.cortemgroup.com

CENELEC EN 60079-0: 2012, EN 60079-7: 2015, EN 60079-28: 2015, EN 60079-31: 2014 and
Standards: EUROPEAN DIRECTIVE 2014/34/UE
IEC 60079-0: 2011-06, IEC 60079-7: 2015, IEC 60079-28: 2015, IEC 60079-31:2013

With temperature class T6 and maximum surface temperature


Ambient Temp.: -40°C (-50°C) +40°C T85°C.

With temperature class T5 and maximum surface temperature


-40°C (-50°C) +55°C T100°C.

Degree of protection: IP66

ED.2022 D.174
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

GENERAL MECHANICAL PROPERTIES


Body and lid: Made from polyester resin in black with antistatic properties
Impact protection rating: IK10
Gasket: Acid, hydrocarbon and high temperature-resistant silicone, located between body and
lid
Mounting: Polyester feet for M6 screws
Certification label: Aluminium plate riveted into lid
Bolts and screws: Stainless steel captive variety

ACCESSORIES AVAILABLE ON REQUEST/ SPECIAL REQUESTS


Possible drilling of the enclosure bottom A maximum of one hole in the center is allowed, 1” NPT o ISO M32x1,5.
Internal anti-condensation coating RAL 2004 (pure orange)
External polyester coating in different colour (specify the RAL number)
Breather valve; Drain valve
Internal mounting plate: stainless steel (code B...-229)
Earth screws in stainless steel
Terminal block mounting rails (code OBO2060/S)
ATEX-CERTIFIED TERMINALS: terminals must be chosen from the list of approved manufacturers: Cabur, Phoenix, ABB
Entrelec, Wago, Weidmuller. When supplied as an Ex i enclosure (for low-voltage instruments), it comes with suitably
identified blue terminals.
Only use cable glands that meet ATEX, IECEx directive requirements. Use gaskets and lock nuts on entries to ensure IP66 protection.

OVERVIEW OF SIZES

90x90 110x110 170x110 147x147 305x147 305x230 470x305 620x305

D.175 ED.2022
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

ENCLOSURE SELECTION CHART

Code Outside dimensions Inside dimensions Mounting Weight


A B C a b c S1 X Y X1 ØD kg

SA090907/P 90 90 73 84 84 52 3 74 74 - 6.5 0.30

SA111108/P 110 110 83 104 104 65 3 94 94 - 6.5 0.40

SA171108/P 170 110 83 164 104 65 3 154 94 - 6.5 0.80

SA141410/P 147 147 100 135 135 79 3 131 131 - 6.5 1.00

SA301410/P 305 147 110 296 138 90 4.5 285 127 - 6.5 1.90

SA302310/P 305 230 110 296 221 90 4.5 285 210 - 6.5 2.50

SA302318/P 305 230 190 296 221 165 4.5 285 210 - 6.5 3.10

SA473018/P 470 305 195 460 295 175 5 450 285 225 6.5 4.70

SA623018/P 620 305 185 608 293 160 5 560 285 260-300 8 6.30

DIMENSIONAL DRAWING

Dimensions in mm

ED.2022 D.176
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

THREAD COMPARISON CHART

D
1 2 3 4 5 6 7 8
Thread diameter
ISO 261/965 20x1.5 25x1.5 32x1.5 40x1.5 50x1.5 63x1.5 75x1.5 85x2
Through hole Ø20.5 Ø25.5 Ø32.5 Ø40.5 Ø50.5 Ø63.5 Ø75.5 Ø85.5

As required by the current standard, holes can be drilled by Cortem or by authorized partners who
hold a production notification in accordance with ATEX Directive .

HOLE DRILLING IN BODY


Sides A and C Sides B and D
TYPE OF
ENCLOSURE Drilling MAXIMUM QUANTITY PER HOLE TYPE Drilling MAXIMUM QUANTITY PER HOLE TYPE
area area
mm 1 2 3 4 5 6 7 8 mm 1 2 3 4 5 6 7 8

SA090907/P 48x45 1 1 - - - - - - 48x45 Square box


SA111108/P 58x55 2 2 1 1 1 - - - 58x55 Square box
SA171108/P 68x55 2 2 1 1 1 - - - 128x55 5 3 2 2 2 - - -
SA141410/P 100x65 6 3 2 1 1 1 - - 100x65 Square box
SA301410/P 100x65 6 3 2 1 1 1 - - 255x65 12 11 5 4 4 3 - -
SA302310/P 180x65 8 7 5 3 2 2 - - 260x65 12 11 5 4 4 3 - -
SA302318/P 180x140 16 14 9 8 5 4 2 2 258x140 24 22 14 11 8 6 3 2
SA473018/P 258x140 24 18 14 8 8 6 3 2 380x140 36 24 18 12 12 8 6 2
SA623018/P 248x117 18 15 10 8 6 3 2 2 434x117 32 26 16 14 12 6 4 4

D.177 ED.2022
SA-...P series Features of junction boxes with terminals

Brass continuity plates Modular terminals installed


for earthing directly on rails mounted on mounting plate
or directly on continuity plate

Cable glands with nickel-


plated brass lock nut

Plugs with nickel-plated brass lock nut

These enclosures are customized based on size, on the number of terminals or cables they are due to accommodate, or taking into account the number
of cable entries and cabling requirements inside a system. Hence we can produce tailor-made solutions as long as you provide us with the appropriate
parameters required at the quote request stage, such as the number of cable glands, unions or sealing fittings to be installed, so that we can determine the
most suitable size of enclosure. All terminals can be fitted with your requested accessories and mounted on special rails that are fastened to the enclosure's
internal mounting plates. Terminal strips can be arranged in various ways, as specified by the customer and always within the limits allowed by the certificate.
The options are vertical, horizontal, in a number of rows, or on different levels using suitable spacers.

ELECTRICAL FEATURES

Signal circuits applications


Standard applications T6/T75°C T4/T100°C
max. Tamb +60°C max. Tamb +85°C
Rated voltage: 1000 Vac/dc - -
1 A for exec. Ex eb 10 A for exec. Ex eb
Rated current: 312 A
100 mA for exec. Ex ia 100 mA for exec. Ex ia
Rated frequency: 50/60 Hz - -
Terminal section: 1.5 ÷ 300 mm 2
- -

Marking Terminal type Description

Enclosures containing increased


Ex II 2GD Ex eb IIC T... Gb - Ex tb IIIC T... Db IP66 Ex e terminals only safety terminals to standard EN
60079-7

Enclosures containing increased


Ex e and Ex i safety terminals and intrinsic safety
Ex II 2GD Ex eb ia IIC T... Gb - Ex tb ia IIIC T... Db IP66
terminals terminals to standards EN 60079-7
and EN 60079-11

Enclosures containing intrinsic safety


Ex II 2GD Ex ia IIC T... Gb - Ex ia IIIC T... Db IP66 Ex i terminals only terminals to standard EN 60079-11;
enclosures are still category 2

ED.2022 D.178
SA-...P series Features of junction boxes with terminals
Examples of terminal strips with minimum installation distances
> 50mm

Ex i terminals Ex e terminals

> 50mm

Ex i terminals Ex e terminals

> 50mm

Notes:
Reference must be made to the minimum distances given, bearing in mind the space required for
internal wiring.
Only ATEX-certified terminals are allowed inside the enclosures.
Ex i rated terminals must be suitably labelled or coloured differently so they are clearly identifiable.
Ex i cable entries must be suitably identified with either labelling or blue markings on cable glands
or the enclosure's sides.

MAXIMUM NUMBER OF TERMINALS


HOUSED
TYPE OF
ENCLOSURE TERMINAL CROSS-SECTIONAL AREA
1.5 2.5 4 6 10 16 25

SA090907/P 9 7 6 5
SA111108/P 13 10 8 7 5
SA171108/P 27 21 17 14 11 9
SA141410/P 22 16 14 11 9 7
SA301410/P 57 44 37 30 24 20 15
SA302310/P 2x58 2x44 2x37 2x30 2x24 2x20 2x15
SA302318/P 2x58 2x44 2x37 2x30 2x24 2x20 2x15
SA473018/P 2x97 2x74 2x63 2x51 2x41 2x34 2x25
SA623018/P 2x133 2x101 2x86 2x70 2x56 2x46 2x35

Eg. 2x22= 2 rows of 22 terminals (total 44 terminals). The maximum number of standard terminals refers to the mounting of CABUR terminals.
The data in the table are given as a rough guide only based solely on the size of the enclosures and the space taken up by the terminals.

D.179 ED.2022
SA-...P series Features of junction boxes with terminals

The permissible maximum power dissipation, in order to retain a T6 temperature class with an ambient temperature up
to +40°C or T5 class with an ambient temperature of 55°C, is not to exceed the values given in the tables below.
For an ambient temperature of +60°C, maximum power dissipation must be reduced by 25%, and rated current
reduced by 15%.
The maximum current values for terminal strips used for low-voltage circuits (signalling units) with a T6 temperature
class and maximum ambient temperature of +60°C or T4 and maximum ambient temperature +65°C and +85°C, are
as follows:
+60°C T6 -> max 1A Ex e, max 100mA Ex ia
+85°C T4 -> max 10A Ex e, max 100mA Ex ia
The values given in the tables on the coming pages refer to the maximum number of conductors allowed for a conductor
with a given cross-sectional area and a given maximum current. All incoming wires and active internal links (made by
wires) count as wires. Earth connections (i.e. passive connections) do not count.
When DIN/Omega rails are installed on the internal mounting plate (instead of using the relevant mounting plate
fastening holes), the number of terminals may be slightly less than the number given in the tables.
Other types of terminals can be used up to the space limit of the box. Whatever the case, all terminals used shall be
ATEX and/or IEC Ex certified. Size 35mm2 terminals can be used for conductors with a cross-sectional area of 25mm2.
The maximum number of terminals and maximum number of rows given in the tables is an indicative value: you must
take into account the cable entries on the sides of the boxes. The internal overall dimensions of cable glands/lock nuts
and the overall dimensions of conductors must be taken into consideration to allow for wiring.
In some cases, it may be necessary to reduce the number of terminals or the number of rows.
Example of how to calculate the maximum number of conductors.
Referring to table SA141410/P: 6 conductors with 6mm2 cross-section with 26A continuous current is the limit of this box.

Consequently, box SA141410/P is suitable for containing 3 x 6mm2 terminals (2 conductors for each terminal) with a
max. current of 26A.
There is space for 11 x 6mm2 terminals in the box. The remaining 8 terminals (11-3) can be added and used for low-
current circuits indicated in area "1" of the table (in this case max. 8-10A).

Combined mounting for electrical circuits with different sized cables is possible provided the values given are used
proportionally.
For example:
Nominal X-sect. area (mm2) Current (A) Quantity Capacity

2,5 8 16 (di 46) 34,8%

4 11 12 (di 36) 33,3%

10 26 4 (di 13) 30,8%

Totale 98,9% <100%

Table showing maximum power dissipation and current Table showing maximum power dissipation and current
for ambient temperature +40°C and +55°C for ambient temperature +60°C
Maximum current [A] per conductor cross- Maximum current [A] per conductor cross-
P sectional area in mm2 P sectional area in mm2
Enclosure Enclosure
[W] [W]
1.5 2.5 4 6 10 16 25 1.5 2.5 4 6 10 16 25
SA090907/P 5.6 11 15 21 26 37 49 67 SA090907/P 4.2 9 12 17 22 31 41 57
SA111108/P 7.5 11 15 21 26 37 49 67 SA111108/P 5.6 9 12 17 22 31 41 57
SA171108/P 8.8 11 15 21 26 37 49 67 SA171108/P 6.6 9 12 17 22 31 41 57
SA141410/P 7.8 11 15 21 26 37 49 67 SA141410/P 5.8 9 12 17 22 31 41 57
SA301410/P 15 11 15 21 26 37 49 67 SA301410/P 11.2 9 12 17 22 31 41 57
SA302310/P 16 11 15 21 26 37 49 67 SA302310/P 12 9 12 17 22 31 41 57
SA302318/P 17.5 11 15 21 26 37 49 67 SA302318/P 13.1 9 12 17 22 31 41 57
SA473018/P 42 11 15 21 26 37 49 67 SA473018/P 31.5 9 12 17 22 31 41 57
SA623018/P 52 11 15 21 26 37 49 67 SA623018/P 39 9 12 17 22 31 41 57

ED.2022 D.180
SA-...P series Features of junction boxes with terminals

Instructions for determining which enclosure is best suited based on the planned number of conductors and terminals.

: In this section of the table that has not been filled in, once you have followed the instructions and complied with the
values given for the enclosure's internal wiring, you can add as many terminals as you want up to the space limit of the box.
: Any wiring that falls within this section of the table that has not been filled in is not covered by the certificate.

"C. No." row: the values given refer to the maximum number of CABUR terminals physically allowed inside the relevant
enclosure. These values are expressed as the product of the rows multiplied by the number of terminals on each row.
"W. No." row: the same as above, but this time referring to Weidmuller terminals.
The terminal brands are mentioned just to give an idea of the quantity of terminals that can be housed inside the enclosure.
The other values given in the cells along the table's diagonal define the maximum number of conductors allowed, based
on their cross-sectional area and maximum current.

Tables showing maximum number of conductors

(N° of terminals = n° of conductors


2
)
SA090907/P SA111108/P SA141410/P
Current Cross-sectional area in mm2 Current Cross-sectional area in mm2 Current Cross-sectional area in mm2
(A) 1.5 2.5 4 6 10 16 25 (A) 1.5 2.5 4 6 10 16 25 (A) 1.5 2.5 4 6 10 16 25
1 1 1
8 17 8 19 32 8 19 32
10 11 10 12 20 29 10 12 20 29
11 9 15 11 10 17 24 11 10 17 24 32
15 8 11 15 9 13 17 15 9 13 17 25
21 6 7 10 21 6 9 12 21 7 9 13 18 23
26 5 7 9 26 6 8 11 26 6 8 11 15
37 3 4 6 37 4 5 7 37 4 6 7
49 3 3 49 3 4 49 3 4
67 2 67 2 67 2
C. No. C. No. C. No. 16 14 11 9 7 5
W. No. 11 7 6 5 W. No. 16 11 9 7 5 W. No. 26 18 15 11 9 7 5
Maximum power dissipation with T6 Maximum power dissipation with T6 Maximum power dissipation with T6
temperature class must not exceed 5.6W temperature class must not exceed 7.5W temperature class must not exceed 7.8W

SA171108/P SA301410/P SA302310/P


Current Cross-sectional area in mm2 Current Cross-sectional area in mm2 Current Cross-sectional area in mm2
(A) 1.5 2.5 4 6 10 16 25 (A) 1.5 2.5 4 6 10 16 25 (A) 1.5 2.5 4 6 10 16 25
1 1 1
8 21 35 8 27 46 67 8 27 46 68 94 142
10 14 23 32 10 18 29 43 59 90 10 18 29 43 60 91
11 11 19 27 36 11 15 24 36 49 74 11 15 24 36 50 75 107
15 10 14 19 28 38 15 13 19 26 40 56 79 15 13 19 27 41 58 81
21 7 10 14 19 26 21 10 13 20 29 40 21 10 14 21 29 41
26 6 9 13 17 26 9 13 19 26 26 9 13 19 27
37 5 6 8 37 7 9 13 37 7 9 13
49 4 5 49 5 7 49 5 8
67 3 67 4 67 4
C. No. C. No. 43 37 30 24 20 14 C. No. 2x44 2x37 2x30 2x24 2x20 15
W. No. 32 22 19 14 11 9 W. No. 69 48 40 30 24 20 14 W. No. 2x70 2x48 2x40 2x30 2x24 2x20 15
Maximum power dissipation with T6 Maximum power dissipation with T6 Maximum power dissipation with T6
temperature class must not exceed 8.8W temperature class must not exceed 15W temperature class must not exceed 16W

SA302318/P SA473018/P SA623018/P


Current Cross-sectional area in mm2 Current Cross-sectional area in mm2 Current Cross-sectional area in mm2
(A) 1.5 2.5 4 6 10 16 25 (A) 1.5 2.5 4 6 10 16 25 (A) 1.5 2.5 4 6 10 16 25
1 1 1
8 30 49 73 102 155 8 51 84 128 181 282 8 59 98 150 215 338
10 19 32 47 65 99 10 32 54 82 116 180 10 38 63 96 137 216
11 16 26 39 54 82 118 166 11 27 45 68 96 149 219 317 11 31 52 80 113 179 265 388
15 14 21 29 44 63 89 15 24 36 51 80 118 170 15 28 43 61 96 143 208
21 11 15 23 32 45 21 19 26 41 60 87 21 22 31 49 73 106
26 10 15 21 30 26 17 27 39 57 26 20 32 47 69
37 7 10 15 37 13 19 28 37 16 23 34
49 6 8 49 11 16 49 13 20
67 4 67 9 67 10
C. No. 2x44 2x37 2x30 2x24 2x20 15 C. No. 2x74 2x62 2x51 2x40 2x33 2x25 C. No. 2x101 2x85 2x69 2x55 2x46 2x34
W. No. 2x70 2x48 2x40 2x30 2x24 2x20 15 W. No. 2x116 2x81 2x68 2x51 2x40 2x33 2x25 W. No. 2x159 2x111 2x93 2x69 2x55 2x46 2x34
Maximum power dissipation with T6 Maximum power dissipation with T6 Maximum power dissipation with T6
temperature class must not exceed 17.5W temperature class must not exceed 42W temperature class must not exceed 52W

D.181 ED.2022
SA-...P series Features of junction boxes with terminals

Codes of terminals used to determine maximum number of terminals


The other values given in the cells along the table's diagonal define the maximum number of conductors
allowed, based on their cross-sectional area and maximum current.

Sq mm 1.5 2.5 4 6 10 16 25 35
Cabur CBD 2 CBD 4 CBD 6 CBD 10 CBD 16 CBD 35
Weidmuller WDU 1.5 WDU 2.5 WDU 4 WDU 6 WDU 10 WDU 16 WDU 35

Sq mm 50 70 95 120 150 185 240 300


Cabur CBD 50 CBD 70 GPM95/CC GPM150/CC GPM240/CC
Weidmuller WDU 50 WDU 70 WDU 70/95 WDU 120/150 WDU 240

ATEX - IECEx label


for terminal enclosures Data filled in:
1. year of manufacture
2. serial number
3. product code
4. ambient temperature
5. temperature class and maximum surface
6. temperature of cables
7. electrical specs per certificate

DON'T FORGET TO ORDER THE ACCESSORIES


Example: Enclosure type Internal mounting plate Cable glands, +
+ + RICAMBIO

SA302310/P B32-229 unions other...see key ACCESSORIO

Continuity plate for all four Continuity plate for single


enclosure sides enclosure side

Plate Code
Enclosure Plate Code
Long side Short side
SA090907/P B-388 B-455
SA111108/P B-389 B-456
SA141410/P B-390 B-457
SA171108/P B-391 B-458 B-456
SA301410/P B-392 B-459 B-457
SA302310/P B-393 B-459 B-460
SA302318/P B-394 B-461 B-462
SA473018/P B-395 (2x) B-462 B-461
SA623018/P - (2x) B-463 B-463

ED.2022 D.182
SA, SAG... series Features of junction boxes with equipment

JUNCTION BOXES WITH EQUIPMENT (FIELDBUS, PROXIMITOR, HEATER...)

Example of junction box with thermostat Example of junction box with proximitor Example of junction box with transmitter

Equipment that can be installed in the junction boxes in accordance with the CML 16 ATEX 3163X or
IECEx CML 16.0074X certificate are described in the following table:

Part Number of certificate Marking

Series 3300Xl Proximitor IECEx BAS 04.0055X Ex ia IIC

PTB 10 ATEX 2015U


Splice Cassette type 8186 Ex op pr IIC
IECEx PTB 10.0060U

NEMKO 11 ATEX 1098X


Enclosure Heater (TEF Series) Ex e IIC; Ex e mb IIC
IECEx NEM 11.0005X

PTB 02 ATEX 1116X


Heater, type SL.. THERM D.. T.. Ex db IIC; Ex tb IIIC
IECEx PTB 07.0055X

PTB 02 ATEX 1041X


Heater, type CP.. THERM D.. T.. Ex db IIC; Ex tb IIIC
IECEx PTB 07.0052X

PTB 04 ATEX 2100X


Fieldbus Segment protector type R-SP-E Ex e mb IIC; Ex eb mb IIC
IECEx PTB 05.0010X

KIVA 15 ATEX 0033X


Temperature Trasmitter Model IPAQ C202X Ex ia IIC
IECEx KIWA 15.0015X

KIVA 14 ATEX 0003X


Temperature Trasmitter Model IPAQ C520X Ex ia IIC
IECEx KIWA 14.0001X

BVS 13 ATEX E 121X Ex e ib mb [ia Ga] IIC T4 Gb


Fieldbus Barrier type R4D0-FB-IA
IECEx BVS 13.0119X Ex e ib mb [ia IIIC Da] IIC T4 Gb

LCIE 01 ATEX 6073X


Heating Resistor type CREx 020 Ex d IIC; Ex tb IIIC
IECEx LCI 07.0020X

LCIE 01 ATEX 6074


Regulating Thermostat type REx Ex d IIC; Ex tb IIIC
IECEx LCI 07.0021

KEMA 03 ATEX 1555X


Interconnection block for fieldbus type F240 to F273 Ex ia IIC
IECEx LCI 11.0068X

KEMA 05 ATEX 2006


Fieldbus XE Megablock and Terminator Ex eb mb IIC
IECEx DEK 16.0036X

Attention: please contact our sales office for further information.

D.183 ED.2022
SA-...P series Features of junction boxes with terminals

DIMENSIONS
ILLUSTRATION DESCRIPTION MODEL CODE KEY
A B
SA090907/P 82 48 B09-229
Internal mounting
plates SA111108/P 100 68 B11-229
SA141410/P 137 105 B14-229
Thickness 2.5mm
Aluminium SA171108/P 159 67 B17-229
SPARE PART

SA301410/P 285 97 B31-229 ACCESSORY

Galvanized steel
SA302310/P
(B...-229AC) 285 180 B32-229
SA302318/P
Stainless steel SA473018/P 453 254 B43-229
(B...-229IN)
SA623018/P 603 249 B64-229

ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY

Breather and drain Thread diameter Material:


ECD-210S
SPARE PART

valve ISO 7-R 3/8” stainless steel ACCESSORY

ISO M20x1,5 ECDE-B1B


Breather valve
ISO M25x1,5 Material: ECDE-B2B SPARE PART

ISO M20x1,5 stainless steel ECDE-D1B


ACCESSORY

Breather and drain


valve ISO M25x1,5 ECDE-D2B

SA090907/P
Low lid SA111108/P
B-0105
enclosures SA141410/P
SA171108/P
Hinges Material: SPARE PART

(2 per enclosure) stainless steel ACCESSORY

SA301410/P
High lid SA302310_18/P
B-0106
enclosures SA473018/P
SA623018/P

M8 K-0307/1
Through earth Material: SPARE PART

connection stainless steel ACCESSORY

M6 K-0307/2

Entry
PLG...
SPARE PART

blanking plugs ACCESSORY

Cable glands
For models and codes, visit NAV... SPARE PART
complete with
www.cortemgroup.com NEV... ACCESSORY

O-rings and unions

Adapters and
RE...
SPARE PART

reducers ACCESSORY

Lid-mounted
For control and signalling device models and codes, see M-0... SPARE PART
control and
control and monitoring device chapter (Ex de) ACCESSORY

signalling devices

Brass continuity
B-...
SPARE PART
For models and codes, see chart given earlier
plates for earthing ACCESSORY

ED.2022 D.184
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA090907/P

Width/Depth/Height: 90/90/73mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1.5 mm 2
1x9
Ambient temperature: -40°C +55°C (+40°C)
2.5 mm 2
1x7
Certification: 4 mm 2
1x6
CESI 03 ATEX 333 (ATEX) 6 mm 2
1x5
IEC Ex CES 13.0001 (IECEx) 10 mm 2
- Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 - standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
-
The data in the table are given as a rough
guide only based solely on the size of the
Accessories enclosures and the space taken up by the
terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B09-229 Number of cable glands
2.5mm-thick galvanized steel: B09-229AC
Hole
2.5mm-thick stainless steel: B09-229IN type
A/C B/D
Hinges (two each type): B-0105 M16 1 1
Breather and drain valve: ECD-210S M20 1 1
M25 1 1

Other: M32 - -
As required by the current standard, holes
1mm-thick brass continuity plates M40 - - can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M50 - - in accordance with ATEX Directive .
Cable glands M63 - -
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

D.185 ED.2022
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA111108/P

Width/Depth/Height: 110/110/83mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1.5 mm 2
1x13
Ambient temperature: -40°C +55°C (+40°C)
2.5 mm 2
1x10
Certification: 4 mm 2
1x8
CESI 03 ATEX 333 (ATEX) 6 mm 2
1x7
IEC Ex CES 13.0001 (IECEx) 10 mm 2
1x5 Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 - standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
-
The data in the table are given as a rough
guide only based solely on the size of the
Accessories enclosures and the space taken up by the
terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B11-229
Number of cable glands
2.5mm-thick galvanized steel: B11-229AC
2.5mm-thick stainless steel: B11-229IN Hole
A/C B/D
type
Hinges (two each type): B-0105
M16 3 3
Breather and drain valve: ECD-210S
M20 2 2
M25 1 1

Other: M32 1 1
As required by the current standard, holes
1mm-thick brass continuity plates M40 - - can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M50 - - in accordance with ATEX Directive .
Cable glands M63 - -
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

ED.2022 D.186
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA171108/P

Width/Depth/Height: 170/110/83mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1.5 mm 2
1x27
Ambient temperature: -40°C +55°C (+40°C)
2.5 mm 2
1x21
Certification: 4 mm 2
1x17
CESI 03 ATEX 333 (ATEX) 6 mm 2
1x14
IEC Ex CES 13.0001 (IECEx) 10 mm 2
1x11 Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 1x9 standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
-
The data in the table are given as a rough
guide only based solely on the size of the
Accessories enclosures and the space taken up by the
terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B17-229 Number of cable glands
2.5mm-thick galvanized steel: B17-229AC
Hole
2.5mm-thick stainless steel: B17-229IN type
A/C B/D
Hinges (two each type): B-0105 M16 3 8
Breather and drain valve: ECD-210S M20 2 5
M25 1 3

Other: M32 1 2
As required by the current standard, holes
1mm-thick brass continuity plates M40 - - can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M50 - - in accordance with ATEX Directive .
Cable glands M63 - -
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

D.187 ED.2022
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA141410/P

Width/Depth/Height: 147/147/100mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1.5 mm2
1x22
Ambient temperature: -40°C +55°C (+40°C)
2.5 mm2
1x16
Certification: 4 mm 2
1x14
CESI 03 ATEX 333 (ATEX) 6 mm 2
1x11
IEC Ex CES 13.0001 (IECEx) 10 mm 2
1x9 Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 1x7 standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
-
The data in the table are given as a rough
70 mm 2 - guide only based solely on the size of the
Accessories enclosures and the space taken up by the
120 mm2 - terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B14-229
Number of cable glands
2.5mm-thick galvanized steel: B14-229AC
2.5mm-thick stainless steel: B14-229IN Hole
A/C B/D
type
Hinges (two each type): B-0105
M16 6 6
Breather and drain valve: ECD-210S
M20 6 6
M25 3 3

Other: M32 2 2
As required by the current standard, holes
1mm-thick brass continuity plates M40 1 1 can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M50 - - in accordance with ATEX Directive .
Cable glands M63 - -
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

ED.2022 D.188
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA301410/P

Width/Depth/Height: 305/147/110mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1,5 mm 2
1x57
Ambient temperature: -40°C +55°C (+40°C)
2,5 mm 2
1x44
Certification: 4 mm 2
1x37
CESI 03 ATEX 333 (ATEX) 6 mm 2
1x30
IEC Ex CES 13.0001 (IECEx) 10 mm 2
1x24 Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 1x20 standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
1x15
The data in the table are given as a rough
guide only based solely on the size of the
Accessories enclosures and the space taken up by the
terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B31-229 Number of cable glands
2.5mm-thick galvanized steel: B31-229AC
Hole
2.5mm-thick stainless steel: B31-229IN type
A/C B/D
Hinges (two each type): B-0106 M16 6 14
Breather and drain valve: ECD-210S M20 4 12
M25 3 9

Other: M32 2 5
As required by the current standard, holes
1mm-thick brass continuity plates M40 1 4 can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M50 1 3 in accordance with ATEX Directive .
Cable glands M63 - -
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

D.189 ED.2022
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA302310/P

Width/Depth/Height: 305/230/110mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1,5 mm2
2x58
Ambient temperature: -40°C +55°C (+40°C)
2,5 mm2
2x44
Certification: 4 mm 2
2x37
CESI 03 ATEX 333 (ATEX) 6 mm 2
2x30
IEC Ex CES 13.0001 (IECEx) 10 mm 2
2x24 Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 2x20 standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
2x15
The data in the table are given as a rough
guide only based solely on the size of the
Accessories enclosures and the space taken up by the
terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B32-229
Number of cable glands
2.5mm-thick galvanized steel: B32-229AC
2.5mm-thick stainless steel: B32-229IN Hole
A/C B/D
type
Hinges (two each type): B-0106
M16 10 14
Breather and drain valve: ECD-210S
M20 10 12
M25 4 9

Other: M32 3 5
As required by the current standard, holes
1mm-thick brass continuity plates M40 3 4 can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M50 - - in accordance with ATEX Directive .
Cable glands M63 - -
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

ED.2022 D.190
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA302318/P

Width/Depth/Height: 305/230/190mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1.5 mm 2
2x58
Ambient temperature: -40°C +55°C (+40°C)
2.5 mm 2
2x44
Certification: 4 mm 2
2x37
CESI 03 ATEX 333 (ATEX) 6 mm 2
2x30
IEC Ex CES 13.0001 (IECEx) 10 mm 2
2x24 Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 2x20 standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
2x15
The data in the table are given as a rough
guide only based solely on the size of the
Accessories enclosures and the space taken up by the
terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B32-229 Number of cable glands
2.5mm-thick galvanized steel: B32-229AC
Hole
2.5mm-thick stainless steel: B32-229IN type
A/C B/D
Hinges (two each type): B-0106 M20 18 24
Breather and drain valve: ECD-210S M25 12 18
M32 9 14

Other: M40 6 8
As required by the current standard, holes
1mm-thick brass continuity plates M50 4 6 can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M63 2 3 in accordance with ATEX Directive .
Cable glands
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

D.191 ED.2022
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA473018/P

Width/Depth/Height: 470/305/195mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1.5 mm 2
2x97
Ambient temperature: -40°C +55°C (+40°C)
2.5 mm 2
2x74
Certification: 4 mm 2
2x63
CESI 03 ATEX 333 (ATEX) 6 mm 2
2x51
IEC Ex CES 13.0001 (IECEx) 10 mm 2
2x41 Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 2x34 standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
2x25
The data in the table are given as a rough
guide only based solely on the size of the
Accessories enclosures and the space taken up by the
terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B43-229
Number of cable glands
2.5mm-thick galvanized steel: B43-229AC
2.5mm-thick stainless steel: B43-229IN Hole
A/C B/D
type
Hinges (two each type): B-0106
M20 24 36
Breather and drain valve: ECD-210S
M25 18 24
M32 14 18

Other: M40 8 12
As required by the current standard, holes
1mm-thick brass continuity plates M50 8 12 can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M63 3 4 in accordance with ATEX Directive .
Cable glands
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

ED.2022 D.192
SA-...P series Polyester junction boxes (Ex e) and (Ex i)

Zone 1,2,21,22.
Degree of protection IP66.
Polyester body and lid.
Silicone gasket.
Stainless steel bolts and screws.
Impact protection IK10.

Ordering details Internal mounting plate dimensions

Standard polyester enclosure: SA623018/P

Width/Depth/Height: 620/305/185mm

Certification data for enclosures with terminals

Group II Category 2GD

Zone 1- Zone 2 (Gas) Zone 21 - Zone 22 (Dust)


II 2GD Ex eb IIC T.. Gb - Ex tb IIIC T.. Db IP66

II 2GD Ex ia IIC T.. Gb - Ex ia IIIC T.. Db IP66 Max. number of terminals

II 2GD Ex eb ia IIC T.. Gb - Ex tb ia IIIC T.. Db IP66 X-SECT. QTY.


1,5 mm 2
2x133
Ambient temperature: -40°C +55°C (+40°C)
2,5 mm 2
2x101
Certification: 4 mm 2
2x86
CESI 03 ATEX 333 (ATEX) 6 mm 2
2x70
IEC Ex CES 13.0001 (IECEx) 10 mm 2
2x56 Eg. 2x22= 2 rows of 22 terminals (total
44 terminals). The maximum number of
Russian (TR CU) 16 mm2 2x46 standard terminals refers to the mounting of
Brasilian (INMETRO) CABUR terminals.
25 mm 2
2x35
The data in the table are given as a rough
guide only based solely on the size of the
Accessories enclosures and the space taken up by the
terminals.
Internal mounting plate: CODE
2.5mm-thick aluminium: B64-229 Number of cable glands
2.5mm-thick galvanized steel: B64-229AC
Hole
2.5mm-thick stainless steel: B64-229IN type
A/C B/D
Hinges (two each type): B-0106 M20 24 48
Breather and drain valve: ECD-210S M25 18 36
M32 14 28

Other: M40 8 16
As required by the current standard, holes
1mm-thick brass continuity plates M50 8 12 can be drilled by Cortem or by authorized
partners who hold a production notification
Terminals M63 3 6 in accordance with ATEX Directive .
Cable glands
Through earth screw Research conducted using Cortem's new
NAV and NEV series cable glands.

D.193 ED.2022
Features of junction boxes for control, monitoring and signalling units

Control, monitoring and signalling units are used to produce control boards that, when positioned near the electrical equipment being controlled, enable the
electrical system to operate correctly and guarantee the safety of personnel when maintenance is being performed on the system. Because they are fitted with
a Manual/Automatic selector, they allow operators to select the appropriate conditions to enable work to be performed entirely safely. They offer protection
and control for electrical equipment and control circuits located in explosion hazard areas and in particularly aggressive environments. They are used to hold
electrical equipment, such as switches, indicators, contactors, transformers, analogue and digital components, etc.... with the option of external control by
using lid-mounted Cortem control and signalling devices, such as control levers, pushbuttons, indicator lights, etc.... Cortem designs, develops and supplies
full cabling for one or more enclosures tailored to your specific requirements, producing panel boards - including even extremely complex solutions - and
providing a full inspection and testing service on request.
ELECTRICAL FEATURES
Rated voltage: 600 V ac/dc
Max. current on contacts: 16 A
Rated frequency: 50 / 60Hz

MINIMUM DISTANCES BETWEEN CORTEM Ex e CONTACTS (e.g. with reference to CESI 03 ATEX 115 certificate)
1 2 3

Key:
1. indicator light M-0612
2. rotating selector M-0604
3. emergency stop pushbutton M-0605
4. contact block M-0530
5. contact block M-0531
6. pushbutton M-0603
7. earth bar
4 5
8. terminals
9. internal mounting plate

Notes:
"e">12mm: standard version.
Suitable for voltage U<800V
"e">5mm: special versions.
Suitable for voltage U<250V
7
When determining enclosure size, what holes are drilled
and what devices can be installed, we also need to take
into account the space required for internal wiring and
6 9
running the cables.

ED.2022 D.194
Features of junction boxes for control, monitoring and signalling units

TYPE OF Drilling area


ENCLOSURE mm
SA090907/P 70x70

SA111108/P 90x90

SA171108/P 90x150

SA141410/P 127x127

SA301410/P 127x285 TYPE OF HOLES DRILLED

SA302310/P 210x285

SA302318/P 210x285

SA473018/P 285x450

SA623018/P 596x280

For ammeter/ For indicator For control


voltmeter light devices

MINIMUM DISTANCES BETWEEN CORTEM Ex e DEVICES FOR PUSHBUTTON CONTROL STATIONS

Distances for Distances for Distances for KEY


indicator lights ammeter/voltmeter devices with 2 and/or 4 contacts 4-contact device

2-contact device

Ammeter/voltmeter

Indicator light

Notes:
Minimum distances between devices worked out for use of
standard 60x20 plates.
Option of using up to 4 contacts per device for pushbutton
M-0603 and selector M-0604.
Option of using up to 2 contacts per device for emergency stop
pushbutton M-0605.
For more information, refer to the Ex e control, monitoring and
signalling devices chapter.