0% found this document useful (0 votes)
66 views3 pages

LCR Meter: ISO-9001, CE, IEC1010

Manual

Uploaded by

alsotari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views3 pages

LCR Meter: ISO-9001, CE, IEC1010

Manual

Uploaded by

alsotari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

100 Hz╱120 Hz╱1 KHz╱10 KHz╱100 KHz, Professional

LCR METER
Model : LCR-9184, LCR-9183 ISO-9001, CE, IEC1010

SMD TESTER, optional


Model:SMDA-22

SMD TEST CLIP, optional


Model:SMDC-21

LUTRON ELECTRONIC
Professional
LCR SERIES

100 Hz/120 Hz/1 KHz/10 KHz/100 KHz


LCR METER, professional
Model : LCR-9184
* Intelligent microprocessor circuit , professional.
* 19999/1999 counts dual LCD display
* Auto LCR smart check and measurement.
* Test range : ( ex : F = 1 KHz )
L : 200.00 uH to 2000.0 H
C : 2000.0 pF to 2.000 mF
R : 20.000 to 200.0 M
* Series/Parallel modes are selectable.
* DCR mode 200.00 to 200.0M
* Five test frequency are available :
100 Hz/120 Hz/1 KHz/10 KHz/100 KHz
* Ls/Lp/Cs/Cp with D / Q / / ESR Parameter.
* LCD Display with backlight structure.
* Power : DC 9V battery or DC 9V adapter in.
* RS232/USB computer interface.
* Optional SMD test clips, SMDC-21.
* Optional SMD tester, SMDA-22.
Model : LCR-9183
* Function same as the LCR-9184, but without
LCD backlight structure, without sorting function
and the spec. accuracy will large than
LCR-9184.
SMD TESTER
Model : SMDA-22
* Optional SMD tester for LCR-9184, LCR-9183.
* Useful tool for SMD components ( Resistor,
Capacitor,Inductor ) LCR value measurement. SMD TEST CLIP
Model : SMDC-21
* Optional SMD test clip for LCR-9184,LCR-9183.
* Useful test clip for SMD components ( Resistor,
Capacitor,Inductor ) LCR value measurement.

C-1
100 Hz/120 Hz/1 KHz/10 KHz/100 KHz
Ls/Lp/Cs/Cp/Rs/Rp with D/Q/θ /ESR parameters
professional
LCR METER
Model : LCR-9184
FEATURES
* 19,999/1,999 counts dual LCD display. Resistance ( Rp/Rs )
* AutoLCR smart check and measurement.
* Serial/Parallel modes are selectable. Range Accuracy Accuracy Remark
* Ls/Lp/Cs/Cp with D/Q/θ /ESR parameters. 100 Hz/120 Hz 1000 Hz
* Support DCR mode 1.00 Ω to 200.0 MΩ . 20 Ω ±( 1% + 5d ) ±( 1% + 5d ) After Short CAL.
* Five different test frequency are available : 200 Ω ±( 0.5% + 5d ) ±( 0.5% + 5d )
100 Hz/120 Hz/1 KHz/10 KHz/100 KHz. 2000 Ω ±( 0.5% + 5d ) ±( 0.5% + 5d )
* Test AC signal level : 0.6 mV rms typically. 20 KΩ ±( 0.5% + 5d ) ±( 0.5% + 5d )
* Test range : ( ex. F = 1 KHz ) 200 KΩ ±( 0.5% + 5d ) ±( 0.5% + 5d )
L : 200.00 uH to 2000.0 H 2000 KΩ ±( 1% + 5d ) ±( 1% + 5d ) After Open CAL.
C : 2000.0 pF to 2.000 mF 20 MΩ ±( 1% + 5d ) ±( 2% + 5d ) After Open CAL.
R : 20.000Ω to 200.0 MΩ 200 MΩ ±( 2% + 5d ) ±( 5% + 5d ) After Open CAL.
* Multi-level battery detector.
* LCD with green light backlight,easy reading. Range Accuracy Accuracy Remark
* RS232/USB PC Computer interface. 10 KHz 100 KHz
* Can default auto power off. 20 Ω ±( 1% + 5d ) ± ( 2% + 5d ) After Short CAL.
200 Ω ±( 0.5% + 5d ) ± ( 0.5% + 5d )
GENERAL SPECIFICATIONS 2000 Ω ±( 0.5% + 5d ) ± ( 0.5% + 5d )
Display LCD size:56.4 X 52.9 mm. 20 KΩ ±( 0.5% + 5d ) ± ( 0.5% + 5d )
LCD with green backlight ( ON /OFF ) 200 KΩ ±( 0.5% + 5d ) ± ( 0.5% + 5d )
Test frequency 100 Hz/120 Hz/1 KHz/10 KHz/100 KHz 2000 KΩ ±( 1% + 5d ) ± ( 2% + 5d ) After Open CAL.
Function L/C/R Function selector 20 MΩ ±( 2% + 5d ) ------------------- After Open CAL.
Frequency selector
D/Q/θ /ESR selector Capacitance ( Cp/Cs ) : D ≦ 0.1
Sorting mode selector
Backlight Range Accuracy Accuracy Remark
Dissipation 0.000 to 999 100 Hz/120 Hz 1000 Hz
factor 20 pF ±( 2% + 5d ) ± ( 1% + 5d ) After Open CAL.
Quality factor 0.000 to 999 200 pF ±( 1% + 5d ) ± ( 1% + 5d ) After Open CAL.
θ ± 90° 2000 pF ±( 0.8% + 5d ) ± ( 0.8% + 5d ) After Open CAL.
measurement 20 nF ±( 0.5% + 5d ) ± ( 0.5% + 5d )
Sorting ± 0.25%, ± 0.5%, ± 1%, ± 2%, ± 5% 200 nF ±( 0.5% + 5d ) ± ( 0.5% + 5d )
tolerance ± 10%, ± 20%, +80% -20% 2000 nF ±( 0.5% + 5d ) ± ( 0.5% + 5d )
mode 20 uF ±( 0.5% + 5d ) ± ( 0.5% + 5d )
Calibration Open/Short calibration 200 uF ±( 0.5% + 5d ) ± ( 0.5% + 5d ) After Short CAL.
Data Hold Freeze the display reading 2000 uF ±( 1% + 5d ) ± ( 1% + 5d ) After Short CAL.
Data output RS232/USB PC computer interface 20 mF ±( 2% + 5d ) ------------------- After Short CAL.
Power off Auto shut off saves battery life or
manual off by push button Range Accuracy Accuracy Remark
Operating 0℃ to 50℃ 10 KHz 100 KHz
temperature 20 pF ±( 1% + 5d ) ± ( 1% + 5d ) After Open CAL.
Operating Less then 85% R.H. 200 pF ±( 0.5% + 5d ) ± ( 0.5% + 5d ) After Open CAL.
humidity 2000 pF ±( 0.5% + 5d ) ± ( 0.5% + 5d ) After Open CAL.
Power Supply 006P DC 9V battery 20 nF ±( 0.5% + 5d ) ± ( 0.5% + 5d )
* Alkaline or Heavy duty type 200 nF ±( 0.5% + 5d ) ± ( 0.5% + 5d )
DC 9V adapter input 2000 nF ±( 0.5% + 5d ) ± ( 0.5% + 5d )
* AC/DC power adapter is optional. 20 uF ±( 0.8% + 5d ) ± ( 0.8% + 5d )
Power DC 35 mA approximately 200 uF ±( 1% + 5d ) ------------------- After Short CAL.
consumption
Dimension 193 x 88 x 41mm Inductance ( Lp/Ls ) : D ≦ 0.1
Weight 420 g
* meter only Range Accuracy Accuracy Remark
Standard * Instruction manual........................1 PC 100 Hz/120 Hz 1000 Hz
Accessories 20 uH ±( 1% + 5d ) ± ( 1% + 5d ) After Short CAL.
Included 200 uH ±( 1% + 5d ) ± ( 1% + 5d ) After Short CAL.
Optional SMD tester, SMDA-22 2000 uH ±( 0.8% + 5d ) ± ( 0.8% + 5d )
Accessories SMD test clip, SMDC-21 20 mH ±( 0.5% + 5d ) ± ( 0.5% + 5d )
Holster, HS-03 200 mH ±( 0.5% + 5d ) ± ( 0.5% + 5d )
AC to DC 9V adapter 2000 mH ±( 0.5% + 5d ) ± ( 0.5% + 5d )
Hard carrying case, CA-06 20 H ±( 0.5% + 5d ) ± ( 0.5% + 5d )
Soft carrying case, CA-05A 200 H ±( 0.5% + 5d ) ± ( 0.8% + 5d )
2000 H ±( 1% + 5d ) ------------------- After Open CAL.
ELECTRICAL SPECIFICATIONS (23± 5 ℃)
Range Accuracy Accuracy Remark
Resistance ( DCR ) 10 KHz 100 KHz
20 uH ±( 1% + 5d ) ± ( 1% + 5d ) After Short CAL.
Range Accuracy Remark 200 uH ±( 0.8% + 5d ) ± ( 0.8% + 5d ) After Short CAL.
20 Ω ±( 0.5% + 5d ) After Short CAL. 2000 uH ±( 0.5% + 5d ) ± ( 0.5% + 5d )
200 Ω ±( 0.5% + 5d ) 20 mH ±( 0.5% + 5d ) ± ( 0.5% + 5d )
2000 Ω ±( 0.5% + 5d ) 200 mH ±( 0.5% + 5d ) -------------------
20 KΩ ±( 0.5% + 5d ) 2000 mH ±( 0.5% + 5d ) -------------------
200 KΩ ±( 0.5% + 5d )
2000 KΩ ±( 0.5% + 5d ) After Open CAL. Model : LCR-9183
20 MΩ ±( 1% + 5d ) After Open CAL. * Function same as LCR-9184, but without LCD backlight
200 MΩ ±( 2% + 5d ) After Open CAL. structure, without sorting function and the accuracy will be
larger than LCR-9184.
* Appearance and specifications listed in this brochure are subject to change without notice. 1011-LCR9184