0% found this document useful (0 votes)
154 views1 page

ELC-131D & ELC-3131D Specs

The document provides specifications for two LCR meters: the ELC-3131D and ELC-131D. Both devices can measure inductance, capacitance, and resistance. The ELC-3131D has additional features like autorange capability and data logging. The specifications include measurement ranges, accuracy, test frequencies used, and physical dimensions for each model.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
154 views1 page

ELC-131D & ELC-3131D Specs

The document provides specifications for two LCR meters: the ELC-3131D and ELC-131D. Both devices can measure inductance, capacitance, and resistance. The ELC-3131D has additional features like autorange capability and data logging. The specifications include measurement ranges, accuracy, test frequencies used, and physical dimensions for each model.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ELC-131D & ELC-3131D Specifications

ELC-3131D ELC-131D
Features Include:
Full autorange, two major measuring methods: parallel and series, 2W/4W selections (ELC-3131D only).
two selected frequencies, max/min/avg record, D/Q factor test mode, relative mode, calibration, tolerance mode, auto power off
(ELC-131D only).
Parameters Measurement:
L, C, R, and D/Q
Measurement Circuit Mode:
1) Capacitance/Resistance Measurement-Defaults to parallel mode for all ranges.
2) Inductance Measurement-Defaults to series mode for all ranges. Both parallel and series mode date are available through
simple key operation.
Display:
L/C/R: maximum 9999 display except at 10mF (120Hz) and 1mF (1kHz) measurement ranges which have max
1999 display
D/Q: 3 digits, maximum 999 display (AUTO RANGE)
Ranging Mode:
Auto & manual
Test Frequency:
1kHz & 120Hz
Measurement Rate:
1 measurement/second, normal
Response Time:
1 second/DUT (device under test) @ manual range
Power Requirement:
AC 100/120/220/240V 50/60Hz (1) DC 9V battery (2) External DC Adaptor-DC12V (MIN)-15V
(MAX) (load: 50mA min)
Size:
26 (W) x 21 (L) x 7 (H) cm; 1.4kg approx. 90 (W) x 192 (L) x 37 (H) mm; 390 grams
Standard Accessories: Standard Accessories:
Test alligator clips (2 pair), Power cord, square fuse (0.1A or Test alligator clips, battery, manual
0.2A AC fast-blow), manual Optional Accessories:
Holster, DC 12V power adaptor
Resistance
RANGE: 10M , 1M , 100k , 10k , 1k ,100 , 10
Accuracy:
@ 10M (0.6% + 5 digits) 1kHz only @ 10M (2.0% + 8 digits) 1kHz only
@ 1M (0.3% + 3 digits) @ 1M (0.5% + 5 digits)
@ 100k (0.3% + 2 digits) @ 100k (0.5% + 3 digits)
@ 10k (0.3% + 2 digits) @ 10k (0.5% + 3 digits)
@ 1k (0.3% + 2 digits) @ 1k (0.5% + 3 digits)
@ 100 (0.5% + 3 digits) @ 100M (0.5% + 5 digits)
@ 10 (0.6% + 5 digits) @ 10 (1.2% + 8 digits)
Inductance
Test Frequency: 120Hz/1kHz (DF < 0.5)
RANGE: 10000H, 1000H, 100H, 10H, 1H, 100mH, 10mH, 1mH
Accuracy:
@ 10000H (0.3% + (Lx/10000)% + 5 digits) 1kHz only @ 10000H Accuracy not specified 120Hz only
@ 1000H (0.3% + (Lx/10000)% + 5 digits) @ 1000H (1.0% + (Lx/10000)% + 5 digits) 120Hz only
@ 100H (0.3% + (Lx/10000)% + 5 digits) @ 100H (0.7% + (Lx/10000)% + 5 digits) 120Hz
@ 10H (0.3% + (Lx/10000)% + 5 digits) (1.0% + (Lx/10000)% + 5 digits) 1kHz
@ 1H (0.3% + (Lx/10000)% + 5 digits) @ 10H (0.7% + (Lx/10000)% + 5 digits)
@ 100mH (0.3% + (Lx/10000)% + 5 digits) @ 1H (0.7% + (Lx/10000)% + 5 digits)
@ 10mH (0.3% + (Lx/10000)% + 5 digits) @ 100mH (1.0% + (Lx/10000)% + 5 digits) 120Hz
@ 1mH (0.3% + (Lx/10000)% + 5 digits) 1kHz only (0.7% + (Lx/10000)% + 5 digits) 1kHz
@ 10mH (2.0% + (Lx/10000)% + 5 digits) 120Hz
(1.2% + (Lx/10000)% + 5 digits) 1kHz
@ 1mH (2.0% + (Lx/10000)% + 5 digits) 1kHz only
Capacitance
RANGE: 10MF, 1000F, 100F, 10F, 1000nF, 100nF, 10nF, 1nF
Accuracy:
@ 10mF (2.5% + 5 digits) (DF < 0.1) 120Hz only @ 10mF (5.0% + 5 digits) (DF < 0.1) 120Hz only
@ 1000F (0.6% + 5 digits) (DF < 0.1) 120Hz @ 1000F (1.0% + 5 digits) (DF < 0.1) 120Hz
@ 1mF (2.5% + 5 digits) (DF < 0.1) 1kHz @ 1mF (5.0% + 5 digits) (DF < 0.1) 1kHz
@ 100F (0.4% + 3 digits) (DF < 0.5) 120Hz @ 100F (0.7% + 3 digits) (DF < 0.5) 120Hz
(0.6% + 5 digits) (DF < 0.1) 1kHz (1.0% + 5 digits) (DF < 0.1) 1kHz
@ 10F (0.4% + 3 digits) (DF < 0.5) 120Hz @ 10F (0.7% + 3 digits) (DF < 0.5)
(0.4% + 3 digits) (DF < 0.5) 1kHz @ 100nF (0.7% + 3 digits) (DF < 0.5)
@ 100nF (0.4% + 3 digits) (DF < 0.5) 120Hz @ 1000nF (0.7% + 3 digits) (DF < 0.5)
(0.4% + 3 digits) (DF < 0.5) 1Hz @ 10nF (1.0% + 5 digits) (DF < 0.1) 120Hz
@ 1000nF (0.4% + 5 digits) (DF < 0.5) 120Hz (0.7% + 5 digits) (DF < 0.5) 1kHz
(0.4% + 3 digits) (DF < 0.5) 1kHz @ 1000pF (1.0% + 5 digits) (DF < 0.1) 1kHz only
@ 10nF (0.6% + 5 digits) (DF < 0.1) 120Hz
(0.4% + 5 digits) (DF < 0.5) 1kHz
@ 100pF (0.6% + 5 digits) (DF < 0.1) 1kHz only

Specifications subject to change without notice.