0% found this document useful (0 votes)
124 views2 pages

Caracteristicas de FLUKE 117

The document provides specifications for Fluke 114, 115, 116, and 117 digital multimeters. It lists general specifications such as accuracy, voltage protection, display details, temperature ratings, and certifications that apply to all models. It also includes accuracy specifications and measurement ranges for different functions like DC voltage, AC voltage, resistance, diode test, and more. The specifications are broken out by multimeter model number where differences apply.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
124 views2 pages

Caracteristicas de FLUKE 117

The document provides specifications for Fluke 114, 115, 116, and 117 digital multimeters. It lists general specifications such as accuracy, voltage protection, display details, temperature ratings, and certifications that apply to all models. It also includes accuracy specifications and measurement ranges for different functions like DC voltage, AC voltage, resistance, diode test, and more. The specifications are broken out by multimeter model number where differences apply.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Fluke 114, 115, 116 and 117

Digital Multimeters
Extended specifications

Technical Data
General specifications (all models)
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity of 0 % to 90 %.
Maximum voltage between any
terminal and earth ground

600 V

Surge protection

6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2

W Fuse for A input

11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)

Display

Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec

Temperature

Operating: -10 C to +50 C; Storage: -40 C to +60 C

Humidity

0 % to 90 % to 35 C; 75 % to 40 C; 45 % to 50 C

Temperature coefficient

0.1 x (specified accuracy/C) (< 18 C or > 28 C)

Operating altitude

2,000 meters

Battery

9 Volt Alkaline, NEDA 1604A/IEC 6LR61

Battery life

Alkaline: 400 hours typical, without backlight

Safety compliances

ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN
61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1

Certifications

UL, CSA, TUV, N10140 , VDE

IP rating (dust and water protection)

IP42

N10140

Accuracy specifications (all models)


Accuracy ([% of Reading]
+ [Counts])

Model

0.1 mV

0.5 % + 2

114, 115, 116, 117

0.001 V
0.01 V
0.1 V

0.5 % + 2

114, 115, 116, 117

Function

Range

Resolution

DC millivolts

600.0 mV

DC volts

6.000 V
60.00 V
600.0 V

DC, 45 Hz to
500 Hz
Auto-V LoZ true-rms
1

600.0 V

0.1 V

500 Hz to 1 kHz

2.0 % + 3

4.0 % + 3

45 Hz to 500 Hz

500 Hz to 1 kHz

114, 116, 117

AC millivolts1 true-rms

600.0 mV

0.1 mV

1.0 % + 3

2.0 % + 3

114, 115, 116, 117

AC volts1 true-rms

6.000 V
60.00 V
600.0 V

0.001 V
0.01 V
0.1 V

1.0 % + 3

2.0 % + 3

114, 115, 116, 117

Continuity

600

Ohms

600.0
6.000 k
60.00 k
600.0 k
6.000 M
40.00 M

Diode test
Capacitance

LoZ capacitance (power-up option)

1 nF to 500 F

Beeper on < 20 , off > 250 ;


detects opens or shorts of
500 s or longer

114, 115, 116, 117

0.1
0.001 k
0.01 k
0.1 k
0.001 M
0.01 M

0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 2

114, 115, 116, 117

2.000 V

0.001 V

0.9 % + 2

115, 116, 117

1000 nF
10.00 F
100.0 F
9999 F

1 nF
0.01 F
0.1 F
1 F

1.9 % + 2
1.9 % + 2
1.9 % + 2
100 F to 1000 F: 1.9 % + 2
> 1000 F: 5 % + 20

115, 116, 117

10 % + 2 typical

115, 116, 117

All ac ranges except Auto-V LoZ are specified from 1 % to 100 % of range. Auto-V LoZ is specified from 0.0 V. Because inputs below 1 % of
range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from
a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of 3.
AC volts is ac-coupled. Auto-V LoZ, ac mV, and ac amps are dc-coupled.

Accuracy specifications (all models) cont.


Accuracy ([% of Reading]
+ [Counts])

Model

0.1 C
0.2 F

1 % + 102
1 % + 182

116

6.000 A
10.00 A
20 A overload for
30 seconds maximum

0.001 A
0.01 A

1.5 % + 3

115, 117

AC Amps true-rms1 (45 Hz to 1 kHz)

600.0 A

0.1 A

1.5 % + 3 (2.5 % + 3 > 500 Hz)

116

DC amps

6.000 A
10.00 A
20 A overload for
30 seconds maximum

0.001 A
0.01 A

1.0 % + 3

115, 117

DC Amps true-rms

600.0 A

0.1 A

1.0 % + 2

116

Hz (V or A input)2

99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz

0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz

0.1 % + 2

115, 117

99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz

0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz

0.1 % + 2

116

Function

Range

Resolution

Temperature (K-Type thermocouple)

-40 C to 400 C
-40 F to 752 F

AC amps true-rms1 (45 Hz to 500 Hz)

Hz (V input)3

All ac ranges except Auto-V LoZ are specified from 1 % to 100 % of range. Auto-V LoZ is specified from 0.0 V. Because inputs below 1 % of range
are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit
or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of 3. AC volts is
ac-coupled. Auto-V LoZ, ac mV, and ac amps are dc-coupled.
2
AC Volts Hz is ac-coupled and specified from 5 Hz to 50 kHz. AC Amps Hz is dc-coupled and specified from 45 Hz to 5 kHz. Amps input burden
voltage (typical): 6 A input 2 mV/A, 10 A input 37 mV/A.
3
Frequency is ac-coupled, 45 Hz to 50 kHz.
1

Frequency counter sensitivity (models 115, 116, 117)


Typical sensitivity (rms sine wave)
Input range
Volts AC

AC Amps
(115, 117 only)

5 Hz to 45 Hz

45 Hz to 5 kHz

5 kHz to 10 kHz

10 kHz to 50 kHz

6V
60 V
600 V

0.2 V
2V
20 V

0.2 V to 0.3 V
2 V to 3 V
20 V to 30 V

0.3 V to 0.4 V
3 V to 4 V
30 V to 40 V

0.4 V to 1.0 V
4 V to 10 V
40 V to 100 V

6A
10 A

N/A
N/A

0.4 A
0.5 A

N/A
N/A

N/A
N/A

Input characteristics (all models)


Function

Input impedance
(nominal)

Common mode rejection ratio(1 k unbalanced)

Volts AC

> 5 M < 100 pF

> 60 dB at dc, 50 or 60 Hz

Volts DC

> 10 M < 100 pF

> 100 dB at dc, 50 or 60 Hz

~3 k < 500 pF

> 60 dB at dc, 50 or 60 Hz

Auto-V LoZ

Open circuit test voltage


Ohms

< 2.7 V dc

Diode Test

< 2.7 V dc

Full scale voltage

Normal mode rejection

> 60 dB at 50 or 60 Hz

Short circuit current

To 6.0 M

40 M

< 0.7 V dc

< 0.9 V dc
2.000 V dc

Fluke. Keeping your world



up and running.
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands

< 350 A
< 1.2 mA

For more information call:


In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
2006 Fluke Corporation. All rights reserved.
Printed in U.S.A. 11/2006 2793260 D-EN-N Rev A

 Fluke Corporation

Fluke 11X Series Digital Multimeters Extended Specifications

You might also like