Machine Translated by Google
JK1S Series Single Phase Fully Digital Thyristor Power Controller
The products are widely used in industrial electric furnaces, mechanical equipment, glass industry, automobile industry, chemical industry and other industries.
Features
Fully digital control
Integrated open loop, constant voltage, constant current, constant power, power regulation (zero crossing) control, LZ (phase shift zero crossing) control, online power distribution
Equipped with functions in one
With effective value (RMS) control option to achieve effective value control
Equipped with programming interface for multiple switch quantities and analog quantities
The input and output interfaces adopt isolation technology, with strong anti-interference ability
When used for power regulation, power can be distributed online to reduce the impact on the power grid
Standard RS485 communication interface
With single-channel Profibus-DP communication (option)
Heavy-duty design, strong overload capacity
The products are widely used in industrial electric furnaces, mechanical equipment, glass industry, automobile industry, chemical industry and other industries.
Model definition:
enter
JK1S-****: AC100?400V, 30?65Hz
Main circuit power supply JK1S-****/5: AC500V, 30~65Hz
JK1S-****/6: >AC500V, 30~65Hz
Control power AC100~400V, 0.5A, 50/60HZ
supply fan power AC220V, 50/60HZ
output
Output voltage 0-98% of the main circuit power supply voltage (phase shift control)
Rated current See model definition
Control mode Open loop, constant voltage, constant current, constant power, power regulation (zero crossing), LZ control
Control signal Analog, digital, communication
Load properties Resistive, Inductive
Performance index
Control accuracy ÿ1%
stability ÿ0.2%
interface description
Analog input Switch 4 programmable inputs
input Analog output 1 fixed input, 2 programmable inputs
Switch output 2 programmable outputs
2 programmable outputs
Standard configuration:
communication Single RS485 communication interface, supporting Modbus RTU communication;
Support single Profibus-DP communication (option)
Machine Translated by Google
The main parameters:
enter
JK1S-****: AC100?400V, 30?65Hz
Main circuit power supply JK1S-****/5: AC500V, 30~65Hz
JK1S-****/6: >AC500V, 30~65Hz
Control power AC100~400V, 0.5A, 50/60HZ
supply fan AC220V, 50/60HZ
power output
Output voltage 0-98% of the main circuit power supply voltage (phase shift control)
Rated current See model definition
Control mode Open loop, constant voltage, constant current, constant power, power regulation (zero crossing), LZ control
Control signal Analog, digital, communication
Load properties Resistive, Inductive
Performance index
Control accuracy ÿ1%
stability ÿ0.2%
interface description
Analog input Switch 4 programmable inputs
input Analog output 1 fixed input, 2 programmable inputs
2 programmable outputs
Switching output 2 programmable outputs
Standard configuration:
communication Single RS485 communication interface, supporting Modbus RTU communication;
Support single Profibus-DP communication (option)
Selection Table
Dimensions (mm)
model Rated current(A) Weight (kg) Cooling method
(LxWxD ÿ500V)
JK1S-0025 25 330×135×166 4.0 Self-cooling
JK1S-0040 40
6.0 Air Cooling
JK1S-0075 75
Machine Translated by Google
JK1S -0100 100 345 ×135 ×212
JK1S -0150 150
JK1S -0200 200
JK1S -0250 250
370 ×170 ×243 9.0
JK1S -0300 300
JK1S -0350 350
390 ×170 ×255 11.5
JK1S -0450 450
JK1S -0600 600 445 ×185 ×323 16
JK1S -0800 800
535 ×253 ×343 26
JK1S -1000 1000
JK1S -1500 1500 750 ×270 ×350 37
JK1S -2000 2000 900 ×303 ×380 58
JK1S -2500 2500
750 ×540 ×370 66
JK1S -3000 3000