P R O D U C T D ATA S H E E T
CONTROL BOX
CB9 CARELINE ®
Features:
• Connection of max. 4 actuators, type LA31/LA31R
  and LA34/ LA34R, via 4-pole DIN sockets
• Extremely compact design
• Mains voltage: 100/120/230V AC 50-60 Hz
• Output voltage 24V DC
• Protection class: IP54 or 66 (not for wash tunnels)
• Colour: Grey or black
• DIN-socket for handsets:
  - Ax types: HB40, HB60, HB70, DP or FS
  - Px types: HB4XE, HB5XE, HB60M (PM/PN
     versions), HB7XE/W, DPXE or DP1M
• 3.2 m exchangeable straight mains cable
• EOP = Electronic Overload Protection
  (only AC, AD, AF, AG, AS and Px types)
  - AD and AG types CH1+2 via common current
     cut off; CH3 + 4 has no EOP!
  - AS type via individual current cut off
• Px type via pulse measurement
• Locking mechanism for DIN plugs and mains cable
• Electronic protection of the relays for extended
  lifetime, EAS (simple EAS); available on AC, AD,
  AE, AF, AG, AH and Px (not PM and PN) types
• Double power control (FET + relay) monitoring
  on all AC, AD and AE types.
• Class 1 or 2 protection                               The CARELINE® CB9 has been developed for use
• Power supply indication via an LED. Not availabe      together with LA31/LA31R, LA34/LA34R1) and
  with mains cut-off                                    the Rotary actuator, RA40 in the Care & Rehab
• Exchangeable mains fuse from outside                  industry. CB9 and LA31 can be fully integrated
• External battery back up and internal charger         which saves mounting and wiring or be installed
  (only AC, AD, AE, AF, AG and AH types; use            separately.
  notation A for ordering)
• External battery back-up (no internal charger)        Exchangeable mains cables, Electronic Overload
  (only AC, AD, AE, AF, AG and AH types; use            Protection (EOP), EAS, earth connection (Class 1)
  notation B for ordering)                              and exchangeable mains fuse makes CB9 a good
• All functionalities are compatible with mains         choice for the simple hospital and care beds.
  cut-off                                               The CARELINE® CB9 series is available as either
Features only available in Px types:                    analogue (Ax) or µ-processor based (Px) types.
• Choice of 8 different standard software packages.     With LINAK software packages the Px types are
  All standard software packages have either            aimed at applications such as workstations, work
  impulse memory or memory. To use memory in            tables and desks, where parallel drive and/or
  general a handset with memory has to be chosen        memory functions are required. Please consult
• Energy saving function (the control box restores      the ordering example for a detailed description
  to power down when not operated)                      of the article number.
• Compact high power toroidal transformer with
                                                        1)
  low power consumption and low electromagnetic           The combination of LA34R/CB9”PX” is only
  emission                                              available as a special article.
• All actuators, which are used together with Px
  types, must be equipped with reed switch and
  connected with a DIN-plug
AC and AF: Means common measurement on CH1, CH2,            Options (has to be stated separately):
 CH3 and and CH4. If the total current exceeds 5A all       • Can be mounted on the LA31
 channels will be cut off.                                  • Customised software may be ordered. Please see
AD and AG: Means a common current measurement on              the guidelines for design of special software!
  CH1+2. The current will be cut off when the total
  current on both channels reaches approx. 3.4A.            Usage:
  Note: CH1+2 = RA40 connection and CH3+4 = LA31/ • Duty cycle: Max. 10% or 2 min. continuous use
  LA34 connection.                                            followed by 18 min. not in use
                                                            • Ambient temperature: +5° to +40°C
AS: Means an individual current measurement on CH1,
                                                            • Compatible with the Rotary actuator, RA40 (only
  CH2, CH3 and CH4. The current will be cut off only
                                                              AD type)
  when the current on one channel reaches approx. 4A.
                                                            • Compatible with up to max. 4 actuators, type
  Max. current available from the CB9 transformer is
                                                              LA31/LA31R and LA34/LA34R, via 4-pole DIN
  approx. 6.5 A.
                                                              sockets
Example of no protection: If you have CH1 = 3A, CH2 =
                                                            • Medically approved according to EN 60601-1/
3A, CH3 = 3A => 9A in total there is no EOP of the channels
                                                              UL 60601-1
and the CB is overloaded!
Px: Means Electronic Overload Protection via a pulse
measurement.
        Precautions:
        LA34 fast motor is not compatible with any standard versions of CB9, due to high current consumption. For use of
        LA34 standard motor and small motor always use a CB9 with EAS.
        Additionally, actuators with reed switch may not be connected to AC, AD, AE, AF, AG or AH types because of a
        conflict between the CB-signal wires and the reed wires.
CARELINE® CB9
Note: The tolerance between the mounting holes is +/- 0.5 mm.
CB9 CARELINE®
Ordering example:
                            Mains cable
                            Careline, LINAK connector, without earth:                              Black             Grey
                            10 = Straight, EU, straight mains-plug-end and straight CB-end         0015185           0015196
                            11 = Coiled, EU, straight mains-plug-end and straight CB-end           0015186           0015197
                            13 = Straight, UK, angled mains-plug-end and straight CB-end           0015193
                            14 = Straight, Japan, straight mains-plug-end and straight CB-end      0015192           0015253
                            15 = Straight, USA, straight mains-plug-end and straight CB-end        0015194
                            17 = Straight, Aus, straight mains-plug-end and straight CB-end        0015239           0015264
                            19 = Without cable
                            Careline, LINAK connector, with earth:                                 Black             Grey
                            1A = Straight, EU, angled mains-plug-end and straight CB-end           0015183           0015184
                            1B = Coiled, EU, angled mains-plug-end and straight CB-end             0015191           0015198
                            1D = Straight, UK, angled mains-plug-end and straight CB-end           0015275
                            1F = Straight, USA, straight mains-plug-end and straight CB-end        0015195
                            1G = Straight, CH, straight mains-plug-end and straight CB-end         0015242
                            1H = Straight, Aus, straight mains-plug-end and straight CB-end        0015241
                            1J = Without cable
                            Careline, mains cut-off, non-detachable, without earth:                Black             Grey
                            F0 = Straight, EU (only CB9-trafo)                                     00WP039C00-00
                            Careline, mains cut-off, non-detachable, with earth:                   Black             Grey
                            FA = Straight, EU (only CB9-trafo)                                     00WP039C00-0A
                            Mains voltage
                            0 = CB9 transformer 230V
                            1 = CB9 transformer 120V
                            2 = CB9 transformer 100V
                            3 = CB18 transformer 230V (only AF, AG, AH or AS-functionality )
                            4 = CB18 transformer 120V (only AF, AG, AH or AS-functionality)
                            5 = CB18 transformer 100V (only AF, AG, AH or AS-functionality)
                            Fuse cover
                            0 = No
                            1 = Yes (not available together with X0WP039C00-xx)
                            Battery
                            0 = No battery
                            A = Con. for ext. 24V bat. and internal charger (only AC, AD, AE, AF, AG or AH func. and not with mains cut-off)
                            B = Con. for ext. 24V bat. (no internal charger) (only AC, AD, AE, AF, AG or AH functionality)
                            Colour
                            + = Grey
                            - = Black
                            No. of channels 1 - 4
                            Functionality
                            Without microprocessor (analog)
                                                   Compatibel                Compatible
                                                   with rotary                with CB18-
                                                                                                    AS-func. Is not for
                                Current cut-off     actuator         EAS     transformer
                                                                                                    new designs.
                            AS 4,1A at all ch.                                    X
                                                                                                    Please use AC-func.
                            AC 5,0A at all ch.                        X
                                                                                                    Instead!
                            AD 3,4A at ch.1 & 2         X             X
                            AE                                        X
                            AF 5,0A at all ch.                        X             X
                            AG 3,4A at ch.1 & 2                       X             X
                            AH                                        X             X
                            With microprocessor (with memory)
                                                          Impuls drive         EAS
                            PM Single
                            PN Single, alternative funct.      X
                            PA Parallel on ch 1/2              X                X
                            PB Single                          X                X
                            PC Parallel on ch 1/2/3                             X
                            PD Parallel on ch 1/2/3            X                X
                            PH Single                                           X
                            PI Parallel on ch 1/3 and 2/4                       X
                            PJ Parallel on ch 1/3 and 2/4      X                X
                            PP Parallel on ch 1/2                               X
                            Flame Classifications
                            0 = HB
                            1 = V0
                            IP degree
                            4 = IP54
                            6 = IP66
                            Plastic housing
                            1 = Careline (no mains-indicator and no fuse-cover if mains cut-off)
                            Type CB9
        NOTE:
        State separately if CB9 and LA31 are to be mounted together.
BA1800 - External battery box
Ordering example:
                BA18 0 0 - 0200 - 0 0 0
                 1                                                  0 = Not used
                                                                    0 = Not used
                                                                    Cable type:      0 = Starndard
                                                                                     1 = CB7 (Only IP51, 700 mm)
                                                                    - = Not used
                                                                    Cabel length:    From 200 mm to 1300 mm with steps of 50 mm
                                                                    - = Not used
                                                                    IP Protection:   0 = IP51
                                                                                     1 = IP65
                                                                                     2 = IP66
                                                                    Colour:          0 = Black
                                                                                     1 = Grey
                                                                    Type: BA18
              An external charging device is not available as standard article.
              When activating several channels and they are at the same time independent of each other, contact technical
              support (related to simple EAS design).
Various information:
• It is possible to order blind plugs for CB9 CARELINE IP 66
  Order number:
  Grey:              00931082
  Black:             00931081
   O-rings are not needed for these rubber plugs.
• It is also possible to order blind plugs for the external battery box outlet (for BA1800)
  Order number:
  Grey:              00918035
  Black:             00918034
  O-rings:           0007018
                                                                                                                                  LINAK 2007.03 MA M9-02-081-K . Chapter 6.6
   The blind plugs are delivered in plastic bags of 100 units in each bag.
• When ordering a CB with mains cable the O-ring and locking ring are automatically included (to maintain the IP degree)
  When ordering a mains cable you only need to specify if the O-ring and / or locking ring are required.
  Order number:
  O-ring:       0007029
  Locking ring: 00912007
                                                                                                                                  ©
                                                                                                                                  Copyright
Specifications subject to change without prior notice.
It is the responsibility of the product user to determine the suitability
of LINAK A/S products for a specific application. LINAK will at point of
delivery replace/repair defective products covered by the warranty
if promptly returned to the factory. No liability is assumed beyond
such replacement/repair.