L-801A Medium-Intensity

Metal-Halide Rotating Beacons


Compliance with Standards
FAA: L-801A AC 150/5345-12 (Current Edition)
ICAO: Annex 14, para. 5.3.3
Ordering Code 44A4837-X1XX
Uses Type
L-801A beacons are designed primarily for night opera-
0 = Airport
tion as identification and location markers for airports.
Style
Features 1 = Standard Base, Belt-Driven
• Patented belt-drive system eliminates the lubrication
required by conventional gear-drive beacons. (U.S. Power

Approach Lighting
Patent No. 5339224) 0 = 120V AC, 60Hz, without heater, Class I
• Patented liquid-filled lamp connector eliminates the slip 1 = 220-240V AC, 50Hz, without heater, Class I
rings and brushes found on conventional beacons (U.S. 2 = 120V AC, 60Hz, with heater, Class II
Patent No. 5816678) 3 = 220-240V AC, 50Hz, with heater, Class II
4 = 220-240V AC, 60Hz, without heater, Class I
• One clear lens and one aviation green lens
5 = 220-240V AC, 60Hz, with heater, Class II
• No maintenance except lamp replacement
• All moving parts are permanently lubricated Relay
0 = No Relay
• Impedance-protected motor eliminates burn outs
1 = Lamp Monitor/Tell-Tale Relay
• 12 rpm produces 24 flashes per minute
• Two 150-watt pulse-start metal-halide lamps, mounted Packaging
180° apart, have a typical lamp life of 10,000 hours (2-3
Cube Shipping Volume: 48 x 42 x 25 in
years) and produce over 150,000 effective center beam (122 x 107 x 63.5 cm)
candelas
Shipping Weight: 150 lb (68 kg)
• Powerful metal-halide lamps for excellent visibility.
Visible for more than 30 miles (47 km).
Spare Components
• Lamps preset at 5°, adjustable from 2° to 10° above
Description Part No.
horizon
Ballast Assembly 50Hz 0200-0024
• Weatherproof steel cabinet with powder-coated Ballast Assembly 60Hz 0200-0023
international orange finish Belt 0600-0003
• Optional photocell and/or tell-tale relay Fuse, motor, 0.5A 2300-0002
Fuse, lamp, 6.25A 2300-0010
• Mountable on a Hali-Brite Tipdown Pole. See catalog
Lamp, 150W pulse-start metal-halide 3400-0125
sheet 2035 for photo and details.
Lens, amber 2800-0025
• Electrical Power–The beacon operates on 120V AC or Lens, clear 2800-0006
240V AC, 60Hz or 220-240V AC, 50Hz Lens, metal-halide, green 2800-0043
• Power Consumption–Class I: 395W; Class II: 795W Lens clip 1500-0011
Lightning arrestor 0000-0000-1
• Made in the USA and ETL certified by Hali-Brite, Inc.,
Crosby, MN

Operating Conditions
Temperature: Class I: -22°F to +131°F (-30°C to +55°C)
Class II: -67°F to +131°F (-55°C to +55°C)
Wind: Velocities up to 100 mph (161 kph)

Optional Mounting
Tower Mount Part No. 4200-0000 The information contained in this document is subject to change without
notice. Siemens reserves the right to make changes and improvements to its
REA Mount Part No. 4200-0002 products and assumes no responsibility for making these modifications on
any equipment previously sold.

Siemens Airfield Solutions, Inc. Telephone: 614-861-1304 2004 Rev. F


977 Gahanna Parkway Fax: 614-864-2069 Call for beacon manual G - 19
Columbus, OH 43230
L-801H & L-802H Medium-Intensity
Metal-Halide Rotating Beacons
Compliance with Standards
FAA: L-801A & L-801S AC 150/5345-12 (Current
Edition)
ICAO: Annex 14, para. 5.3.3
Ordering Code 44A4838-X1XX
Uses Type
L-801H/L-802H beacons are designed primarily for night 2 = Civilian Heliport
operation as identification and location markers for a 3 = Military Heliport
heliport at airports, hospitals, or military bases. 4 = Civilian Hospital Heliport
5 = Military Hospital Heliport
Features
• Patented belt-drive system eliminates the lubrication Style
Approach Lighting

required by conventional gear-drive beacons. (U.S. 1 = Standard Base, Belt-Driven


Patent No. 5339224)
• Patented liquid-filled lamp connector eliminates the slip Power
rings and brushes found on conventional beacons (U.S. 0 = 120V AC, 60Hz, without heater, Class I
Patent No. 5816678) 1 = 220-240V AC, 50Hz, without heater, Class I
2 = 120V AC, 60 Hz, with heater, Class II
• One clear, one aviation green, and one yellow lens 3 = 220-240V AC, 50Hz, with heater, Class II
• No maintenance except lamp replacement 4 = 220-240V AC, 60Hz, without heater, Class I
• All moving parts are permanently lubricated 5 = 220-240V AC, 60Hz, with heater, Class II
• Impedance-protected motor eliminates burn outs Relay
• 12 rpm produces 36 flashes per minute 0 = No Relay
• Three 175-watt metal-halide lamps, mounted 120° 1 = Lamp Monitor/Tell-Tale Relay
apart, have a typical lamp life of 7,500 hours (1-2
years) and produce over 51,000 effective center beam Packaging
candelas
Cube Shipping Volume: 48 x 42 x 25 in (122 x 107 x 63.5 cm)
• Powerful metal-halide lamps for excellent visibility. Shipping Weight: 175 lb (79 kg)
Visible for more than 30 miles (47 km).
• Lamps preset at 5°, adjustable from 2° to 10° above Spare Components
horizon
Description Part No.
• Weatherproof steel cabinet with powder-coated Ballast Assembly 50Hz 0200-0002-3
international orange finish Ballast Assembly 60Hz 0200-0001-3
• Optional photocell and/or tell-tale relay Belt 0600-0003
Fuse, motor, 0.5A 2300-0002
• Mountable on a Hali-Brite Tipdown Pole. See catalog Fuse, lamp, 8A 2300-0012
sheet 2035 for photo and details. Lamp, 175W metal-halide 3400-0175U
• Electrical Power–The beacon operates on 120V AC or Lens, amber 2800-0025
240V AC, 60Hz or 220-240V AC, 50Hz Lens, clear 2800-0006
Lens, metal-halide, green 2800-0043
• Power Consumption–Class I: 655W; Class II: 1055W Lens, red 2800-0010
• Made in the USA and ETL certified by Hali-Brite, Inc., Lens clip 1500-0011
Crosby, MN Lightning arrestor 0000-0000-1

Operating Conditions
Temperature: Class I: -22°F to +131°F (-30°C to +55°C)
Class II: -67°F to +131°F (-55°C to +55°C)
Wind: Velocities up to 100 mph (161 kph)

Optional Mounting The information contained in this document is subject to change without
Tower Mount Part No. 4200-0000 notice. Siemens reserves the right to make changes and improvements to its
products and assumes no responsibility for making these modifications on
REA Mount Part No. 4200-0002 any equipment previously sold.

2005 Rev. G Siemens Airfield Solutions, Inc. Telephone: 614-861-1304


G - 20 Call for beacon manual 977 Gahanna Parkway Fax: 614-864-2069
Columbus, OH 43230
L-802A High-Intensity Airport
Metal-Halide Rotating Beacon
Compliance with Standards
FAA: L-802A AC 150/5345-12 (Current Edition)
ICAO: Annex 14, para. 5.3.3

Uses
L-802A Rotating Beacons are designed primarily for night
operation as identification and location markers for
airports. L-802A beacons are now available with 250W
and 400W pulse-start metal-halide lamps.
Ordering Code 44A6008-0XXX
Style
Features
1 = Two 400W metal-halide lamps
• Patented belt-drive system eliminates the lubrication

Approach Lighting
2 = Two 250W pulse-start metal-halide lamps
required by conventional gear-drive beacons. (U.S.
3 = Two 400W pulse-start metal-halide lamps
Patent No. 5339224)
• Patented liquid-filled lamp connector eliminates the slip Power
rings and brushes found on conventional beacons (U.S. 0 = 120V AC, 60Hz, without heater, Class I
Patent No. 5816678) 1 = 220-240V AC, 50Hz, without heater, Class I
• One clear lens and one aviation green lens 2 = 120V AC, 60Hz, with heater, Class II
3 = 220-240V AC, 50Hz, with heater, Class II
• No maintenance except lamp replacement
4 = 220-240V AC, 60Hz, without heater, Class I
• All moving parts are permanently lubricated 5 = 220-240V AC, 60Hz, with heater, Class II
• Thermally-protected motor eliminates burn outs
Relay
• 12 rpm produces 24 flashes per minute
0 = No Relay
• Lamps preset at 5°, adjustable from 2° to 10° above 1 = Lamp Monitor/Tell-Tale Relay
horizon
• Lamp Life: Packaging
- Two 400W metal-halide lamps, mounted 180° apart, Cube Shipping Volume: 48 x 42 x 32 in
have a typical lamp life of 15,000 hours (2-3 years) (122 x 107 x 81 cm)
and produce over 90,000 effective center beam Weight: 250 lb (113.4 kg)
candelas
- Two 250W pulse-start metal-halide lamps, mounted
180° apart, have a typical lamp life of 12,000 hours
Operating Conditions
(2-3 years) and produce over 112,000 effective Temperature: Class I: 22°F to +131°F (-30°C to +55°C)
center beam candelas Class II: -67°F to +131°F (-55°C to +55°C)
- Two 400W pulse-start metal-halide lamps, mounted Wind: Velocities up to 100 mph (161 kph)
180° apart, have a typical lamp life of 15,000 hours
(2-3 years) and produce over 121,000 effective Optional Mounting
center beam candelas
Tower Mount Part No. 4200-0000
• Pulse-start lamps fully bright in 3-5 minutes
REA Mount Part No. 4200-0002
• Powerful metal-halide lamps for excellent visibility.
Visible for more than 50 miles (80 km).
Power Consumption
• Weatherproof steel cabinet with powder-coated
international orange finish 400W Metal-Halide Class I 965W
Class II 1365W
• Optional photocell and/or tell-tale relay
250W Pulse-Start Metal-Halide Class I 630W
• Mountable on a Hali-Brite Tipdown Pole Class II 1030W
• Military version available 400W Pulse-Start Metal-Halide Class I 965W
• Electrical Power–The beacon operates on 120V AC or Class II 1365W
220-240V AC, 60Hz or 220-240V AC, 50Hz
• Made in the USA and ETL certified by Hali-Brite, Inc.,
Crosby, MN

2035 Rev. D
Call for beacon manual G - 21
Dimensions Spare Components
Description Part No.
Ballast, 50Hz, 400W 0200-0015
Ballast, 50Hz, 250W pulse-start 0200-0010
Ballast, 50Hz, 400W pulse-start 0200-0016
Ballast, 60Hz, 400W 0200-0005
Ballast, 60Hz, 250W pulse-start 0200-0012
Ballast, 60Hz, 400W pulse-start 0200-0013
Belt 0600-0003
Fuse, motor, 0.5A 2300-0002
Fuse, lamp, 8A (250W pulse-start) 2300-0012
Fuse, lamp, 10A 2300-0003
Lamp, metal-halide, 400W 3400-0400-U-ED28
Lamp, metal-halide, 250W pulse-start 3400-0250PS
Lamp, metal-halide, 400W pulse-start 3400-0400-H75-PS
Lens, aviation green 2800-0044
Lens, clear 2800-0035
Lens clip 0100-0253
Lightning arrestor 0000-0000-1
Approach Lighting

Hali-Brite Tipdown Pole


The Tipdown Pole makes it easy to change lamps and
perform routine maintenance.
• Increases safety–no risk of falling or hazard of working
on a platform
• Easy to operate–Can be quickly lowered and raised by
one person without special equipment. Uses a hand-
operated winch system
• Can be installed in locations inaccessible to bucket trucks
• Not designed for DCB-36 or DCB-224 beacons
• Greatly reduces maintenance costs and downtime
For more information, contact the SAS Sales Department.

The information contained in this document is subject to change without


notice. Siemens reserves the right to make changes and improvements to its
products and assumes no responsibility for making these modifications on
any equipment previously sold.

2035 Rev. D Siemens Airfield Solutions, Inc. Telephone: 614-861-1304


G - 22 Call for beacon manual 977 Gahanna Parkway Fax: 614-864-2069
Columbus, OH 43230
L-802A High-Intensity
Refurbished Airport 224 Double Drum
Metal-Halide Rotating Beacon

Uses
L-802A beacons are designed primarily for night operation
as identification and location markers for airports. Civilian Beacon

Features
• Patented belt-drive system eliminates the lubrication
required by conventional gear-drive beacons. (U.S.
Patent No. 5339224)

Approach Lighting
• Patented liquid-filled lamp connector eliminates the slip
rings and brushes found on conventional beacons (U.S.
Patent No. 5816678)
• One clear lens and one green lens (civilian applications)
• One clear split-beam lens and one green lens (military
applications)
• Qualifies for AIP funding
• Available for exchange or direct purchase
• 12 rpm produces 24 flashes per minute (civilian)
• 6 rpm produces 18 flashes per minute (military) Military Beacon
• All new stainless steel fasteners
• Plated steel parts Ordering Code 44A4840-XXXX
Type
• All new Teflon-coated wire
1 = Military Airport
• Thermally-protected motor eliminates burn outs 2 = Civilian Airport
• Lamps preset at 5°, adjustable from 3° to 7° above
horizon Drive and Base
0 = Gear-Driven, Std. Base
• Powerful 400W metal-halide lamp system for excellent
1 = Belt-Driven, Std. Base
visibility. Visible for more than 80 miles (129 km).
2 = Gear-Driven, Triangle Base
• Two 400W metal-halide lamps have a typical lamp life 3 = Belt-Driven, Triangle Base
of 15,000 hours (3-4 years) and produce over 250,000
effective center beam candelas Power
• Weatherproof aluminum housing with powder-coated 0 = 120V AC, 60Hz, without heater, Class I
international orange finish 1 = 220-240V AC, 50Hz, without heater, Class I
2 = 120V AC, 60Hz, with heater, Class II
• Optional photocell and/or tell-tale relay
3 = 220-240V AC, 50Hz, with heater, Class II
• Electrical Power–The beacon operates on 120V AC, 4 = 220-240V AC, 60Hz, without heater, Class I
60Hz 5 = 220-240V AC, 60Hz, with heater, Class II
• Warranty–Two years on parts and one year on labor
(excludes lamps) Refurbished Condition
1 = Without exchange of beacon core
• Winterization option available for cold climates
2 = With exchange of beacon core
• Power Consumption–Class I: 1100W; Class II: 1500W
with winterization option
Operating Conditions
• Refurbished and retrofitted in the USA by Hali-Brite,
Temperature: Class I: -22°F to +131°F (-30°C to +55°C)
Inc., Crosby, MN
Class II: -67°F to +131°F (-55°C to +55°C)
Wind: Velocities up to 100 mph (161 kph)

2008 Rev. E
Call for beacon manual G - 23
Packaging Spare Components
Cube Shipping Volume: 48 x 55 x 77 in Description Part No.
(122 x 140 x 196 cm) Ballast, 60Hz, 400W 0200-0005
Belt 0600-0001
Shipping Weight: 825 lb (375 kg)
Fuse, lamp, 10A 2300-0003
Lamp, metal-halide, 400W 3400-0400E
Dimensions Lightning arrestor 0000-0000-1
Outer glass, clear 2800-0004
Outer glass, green 2800-0030
Parabolic Mirror 2800-0051
Approach Lighting

The information contained in this document is subject to change without


notice. Siemens reserves the right to make changes and improvements to its
products and assumes no responsibility for making these modifications on
any equipment previously sold.

2008 Rev. E Siemens Airfield Solutions, Inc. Telephone: 614-861-1304


G - 24 Call for beacon manual 977 Gahanna Parkway Fax: 614-864-2069
Columbus, OH 43230
L-802A High-Intensity
Refurbished 36-Inch Double End
Airport Metal-Halide Rotating Beacon

Uses
L-802A beacons are designed primarily for night operation
as identification and location markers for airports.

Features Ordering Code 44A4839-XXXX


• Patented stationary lamp system eliminates the gear Refurbished Condition
lubrication maintenance required by conventional gear- 3 = 400W without exchange of core
drive beacons (U.S. Patent No. 5339224)

Approach Lighting
4 = 400W with exchange of core
• Qualifies for AIP funding
• Available for exchange or direct purchase Drive and Base
0 = Gear-Driven, Std. Base
• 400W metal-halide lamp has a typical lamp life of 1 = Belt-Driven, Std. Base
20,000 hours (3-4 years) and produces over 120,000 2 = Gear-Driven, Triangle Base
effective center beam candelas 3 = Belt-Driven, Triangle Base
• One clear lens and one aviation green lens
• Thermally-protected motor eliminates burn outs Power
0 = 120V AC, 60Hz, without heater, Class I
• 12 rpm produces 24 flashes per minute 1 = 240V AC, 50Hz, without heater, Class I
• All new stainless steel fasteners 2 = 120V AC, 60Hz, with heater, Class II
• Plated steel parts 3 = 240V AC, 50Hz, with heater, Class II
4 = 240V AC, 60Hz, without heater, Class I
• All new Teflon-coated wire 5 = 240V AC, 60Hz, with heater, Class II
• Lamps preset at 5°, adjustable from 2° to 10° above
horizon Options
• Powerful 400W metal-halide lamp system for excellent 0 = No Relay
visibility. Visible for more than 80 miles (129 km). 1 = Lamp Monitoring/Tell-Tale Relay

• Weatherproof aluminum housing with powder-coated


international orange finish
Packaging
Cube Shipping Volume: 48 x 48 x 77 in
• Optional photocell and/or tell-tale relay
(122 x 122 x 196 cm)
• Electrical Power–The beacon operates on 120V AC, 60Hz Weight: 950 lb (431 kg)
• Warranty–Two years on parts and one year on labor
(excludes lamps)
Accessories
• Winterization option available for cold climates
Winterization Package (Heater Kit)
• Power Consumption–Class I: 635W; Class II: 1035W
with winterization option Ordering Code: 8700-0024 (Available installed or in kit
form)
• Refurbished and retrofitted in the USA by Hali-Brite, Power Source: 120V AC
Inc., Crosby, MN Shipping Volume: 1 cu ft
Shipping weight: 6 lb (3 kg)
Operating Conditions
Temperature: Class I: -22°F to +131°F (-30°C to +55°C)
Class II: -67°F to +131°F (-55°C to +55°C)
Wind: Velocities up to 100 mph (161 kph)

2006 Rev. E
Call for beacons manual G - 25
Dimensions Spare Components
Description Part No.
Ballast, 60Hz, 400W 0200-0005
Belt 0600-0001
Fuse, lamp, 10A 2300-0005
Lamp, metal-halide, 400W 3400-0400U
Lens, inner, aviation green 2800-0011
Lens, inner, clear 2800-0033
Lens, left outer sector 2800-0001
Lens, outer bull’s-eye 2800-0003
Lens, right outer sector 2800-0002
Lighting arrestor 0000-0000-1
Approach Lighting

The information contained in this document is subject to change without


notice. Siemens reserves the right to make changes and improvements to its
products and assumes no responsibility for making these modifications on
any equipment previously sold.

2006 Rev. E Siemens Airfield Solutions, Inc. Telephone: 614-861-1304


G - 26 Call for beacons manual 977 Gahanna Parkway Fax: 614-864-2069
Columbus, OH 43230

You might also like