EAGLE SIGNAL brand                                                    CX300 Microprocessor Timer/Counter
Electronic Timers
                                                                                            Microprocessor based
                                                                                            timer/counter housed
                                                                                            in the industrial
                                                                                            standard CYCL-FLEX®
                                                                                            case
                                                                                                                                                       ®
                                                                                                                                 ®
                                                                                                                                   RECOGNIZED   CERTIFIED
The CX300 is a microprocessor based timer/counter housed in a                SPECIFICATIONS
standard 15 terminal CYCL-FLEX® plug-in case which allows easy
removal for programming changes and replacement. Time or count               Time/Count Ranges:
operation, time range, and the type of start input switch operation are
programmed with 7 miniature rocker switches located inside the unit            Sym.        Maximum          Minimum                  Count
housing.                                                                                    Range            Setting                  Rate
The front panel of the CX300 is a sealed membrane keypad which                   1         19999 Cts.         1 Ct.     7500/Sec. 12-50 VDC Count Input
provides excellent protection for most industrial environments. The time         2         19999 Cts.         1 Ct.           500/Min. AC or DC
or count setpoint is entered using the increment and decrement keys for          3         19999 Cts.         1 Ct.           5000/Min. AC or DC
each digit position. The SET and ENT keys provide access to the
setpoint, as well as to the front panel programmable software functions.         4         199.99 Sec.       .01 Sec.
These programmable functions control the pulse output length, setpoint           5         1999.9 Sec.       .1 Sec.
to zero/zero to setpoint cycle progress indication, and count input scale        6         19.999 Sec.      .001 Sec.
factor. The software programming functions are indicated with
                                                                                 7      199 Min.: 59 Sec.    1 Sec.
abbreviated English work prompts to help the user program these
functions without the need for written instructions.                             8       199 Hr.: 59 Min.    1 Min.
■ Keypad lock function allows viewing of setpoint, but does not allow
   unauthorized changes                                                      Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz
                                                                               B6 - 240 VAC, 50/60 Hz
■ 4 1/2 digit (19999) liquid crystal display - .5 inch high digits             Z6 - 24 VAC, 50/60 Hz
■ Annunciators (right of the display) flash to indicate timing or counting   Time Inhibit/Count Line Terminals B & C:
■ Two form C instantaneous contacts and two form C programmed                   CX311/CX341 - 12-50 VDC or 20-28 VAC, 50/60 Hz
   contacts                                                                     CX312/CX342 - 120 VAC, 50/60 Hz or 120 VDC
■ Five time ranges from 19.999 sec. to 199 hr.: 59 min.                      Setting Accuracy: Time: ±0.1% or 50 ms, whichever is larger (0˚ to 60˚C)
■ Three count rate input rate speeds are programmable with a max.
                                                                                Count: 100%
   count display of 19999 - can be extended via count input scale            Repeat Accuracy:
   factor                                                                       Time: ±0.1% or 35 ms, whichever is larger (0˚ to 60˚C)
■ 24, 120, or 240 VAC operations                                                Count: 100%
■ Count input available for 120 volt AC or low voltage AC/DC                 Reset Time: 30 ms following voltage removal from simulated clutch input
   operations                                                                   (CR1)
■ When programmed as timer, count input circuit serves as time inhibit       Power on Response: 300 ms max. after voltage applied to terminal 11
   (without resetting the unit)
                                                                             Operating Temperature: +32˚ to +140˚F (0˚ to +60˚C)
                                                                             Output Rating: Relay: 10 amp (resistive), 120 VAC
                                                                                Mechanical Life: 20 million operations
                                                                                Electrical Life: contingent upon controlled load
                                                                                Solid State: 1 amp, 0-264 VAC, VDC
                                                                             Vibration: Unit function is unaffected by 2.5G sinusoidal vibration magni-
                                                                                tude in both directions of the perpendicular mounting axes imposed from
                                                                                10 to 100 Hz
                                                                             Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
                                                                                60 Hz discharge applied to the grounded front plate at a relative humidity
                                                                                of less than 25%
                                                                             Battery Life: The CX uses a lithium battery with an expected life of 10
                                                                                years
                                                                             Agency Approvals: UL Recognition E96337
                                                                               CSA Certification LR26861
        DANAHER CONTROLS
     EAGLE SIGNAL brand
      Electronic Timers
OUTPUT OPERATING MODES
ON-Delay Operation                                                                            Interval Operation
  The contacts are energized at the end of the timing/counting cycle                              The contacts are energized during the timing/counting cycle and
  and remain energized until the unit is reset.                                                   then shut off at the end of the cycle.
    START INPUT                                                                                    START INPUT
                                                                RESET                                                                                        RESET
  PROGRAMMED                                                                                     PROGRAMMED
   CONTACTS                                                                                       CONTACTS              TIMING OR COUNTING
                          TIMING OR COUNTING                    RESET
Pulse Output Operation                                                                        Pulse and Repeat Operation
   The contacts are energized at the end of the timing/counting cycle                            The contacts are energized at the end of the timing/counting cycle for a
   for a pulse which is user programmable. See Front Panel Feature                               pulse which is user programmable. At the same time that the cycle is
   Programming instructions for details on how to program the pulse                              completed and the pulse output begins, the timing/counting cycle resets
   length..                                                                                      and begins again. This repeat operation continues as long as the start
                                                                                                 circuit is energized.
    START INPUT
                                                                RESET                                START INPUT
  PROGRAMMED                                                                                                                                                   RESET
   CONTACTS                                       PULSE                                          PROGRAMMED
                            TIMING OR                                                             CONTACTS                           PULSE             PULSE
                            COUNTING                                                                                 TIMING OR        TIMING OR
                                                                                                                     COUNTING         COUNTING
MOUNTING
                  DRILL AND TAP FOUR
                  HOLES FOR 8-32 SCREWS
                  (INCLUDED W/UNIT)
         1.406               3.187 + .062
        (35.71)             (80.95 + 1.57)
                            DIA. CUTOUT
                                                                                                  4.250
                                                                                                                    3.062
                                                                                                (107.95)
                                                                                                                   (77.77)
        1.406
       (35.71)
                         1.406          1.406      MTG. HOLE
                        (35.71)        (35.71)     USED FOR
                                                   GROUNDING
                                                   CASE
                                                                               3.812
                                                                                                                                             4.125                 1.625
                                                                              (96.82)
                                                                                                                                           (104.78)               (41.27)
                                                                                                                                                   5.750
                                                                                                                                                  (146.05)
ENCLOSURES                                                                                    ACCESSORIES
   Model No.             NEMA Class                       Description                          Model No.                     Description
     HN308                        1              Surface Mtg. with terminal block              H-5331            Mounting Brackets 2 req'd per timer
     HN364                        1              Surface Mtg. without terminal block           HP50-31           One Hole Mounting Ring
     HN370                        1A             Dual unit cabinet less unit cases and         HP50-131          CYCL-FLEX Water-Sealed Housing provides NEMA 4
                                                 toggle switch, with 9 terminal block                            Hosedown rating for CX series timers/counters
                                                                                               HP50-133          Surface Mounting Adapter to use in place of brackets
                                                                                               PDM-534           1/4 DIN Adapter Plate
ORDERING INFORMATION
                                                                     CX3                 1       2          A6
      OUTPUT TYPE                                                                                                       VOLTAGE & FREQUENCY
         Sym.           Description                                                                                           Sym.     Description
            1         10A DPDT Instantaneous                                                                                   A6    120 VAC, 50/60 Hz
                      10 DPDT Delayed Relay Output                COUNT / INHIBIT                                              B6    240 VAC, 50/60 Hz
                                                                  INPUT VOLTAGE
            4         1A Solid State Output                                                                                    Z6    24 VAC, 50/60 Hz
                                                                    Sym.                 Description
                                                                      1       12-50 VDC, 20-28 VAC, 50/60 Hz
                                                                      2       120 VDC, 120 VAC, 50/60 Hz
                                                                                                                                           DANAHER CONTROLS