杭州均测仪器仪表有限公司
JDS6600 series
   Dual-Channel
Function/Arbitrary
DDS Signal Generator
Quick Start Guide
     Rev1.0
     May 2017
                      Hangzhou Junce Instrument Co., Ltd.
Contents
Chapter 1 Overview ..............................................................................4
1, Instrument introduction .........................................................................4
2, Model description .................................................................................4
3, Dimension ............................................................................................4
4, Technical parameters ..........................................................................5
Chapter II Instrument Description ......................................................12
1, Front panel overview ..........................................................................12
2, Display interface description ..............................................................12
3.The key function description ................................................................14
Chapter III Instrument Operation Instructions ...................................14
1, Setting parameters and outputting waveforms in the main
 interface ................................................................................................15
2, MEAS measurement mode interface parameter settings ...................16
3, MOD modulation mode interface parameter settings .........................16
4, System settings interface, parameter settings ....................................17
                                                      3
Check
When you get a new JDS6600 series dual-channel signal generator, it is recommended
that you follow the steps below to check the instrument.
Check the package
If the package is damaged, keep the damaged packaging or shockproof material until the
goods have been fully inspected and the instrument has passed electrical and
mechanical tests. If the instrument is damaged due to shipping, please contact the
shipper and the carrier for compensation.
Check accessories
The contents of accessories are as follows. If the contents do not match or the
instrument is damaged, contact the dealer or the company.
 Host: JDS6600 Series Dual Channel                                1pcs
 Signal Generator
 Accessories: Power Adapter                                       1pcs
 USB cable                                                        1pcs
 Signal connection cable                                          2pcs
 User manual                                                      1pcs
 CD                                                               1pcs
Check the whole machine
If you find that the instrument is damaged, the instrument is not working properly, or fails
the performance test, contact your dealer or our company.
TEL:0371-86106382      QQ1: 1406921960       QQ2: 3155097720
Mail: 1406921960@qq.com,
       3155097720@qq.com
R&D company: Hangzhou Junce Instrument Co., Ltd. WEB:www.junteks.com
                                                 4
                            Chapter 1 Overview
Instrument introduction
JDS6600 series function generator can generate multiple waveforms such as sine wave,
square wave, triangle wave, pulse wave, and arbitrary wave. The frequency range up to
60MHz, with duty cycle adjustment, sweep frequency, frequency signal frequency and
counter function, and the output signal, amplitude, and frequency can be displayed
simultaneously. The series signal generator has excellent amplitude and frequency
characteristics, the appearance of this instrument is exquisite and beautiful.
This instrument is widely used in factories, schools, research institutes and laboratories.
The model description
This series of instruments are divided into five models, the main difference is the
maximum frequency of sine wave output, as described below:
                       Model                  Sine wave output maximum frequency
                  JDS6600-60M                                 60MHz
                  JDS6600-50M                                 50MHz
                  JDS6600-40M                                 40MHz
                  JDS6600-30M                                 30MHz
                  JDS6600-15M                                 15MHz
                                                5
Dimension
Note: unit mm
Technical parameters
     Frequency characteristics
                       JDS6600   JDS6600   JDS6600   JDS6600   JDS6600
                         -15M      -30M      -40M      -50M      -60M
 Sine wave frequency
                       0~15MHz   0~30MHz   0~40MHz   0~50MHz   0~60MHz
        range
     Square wave
   frequency range
                       0~15MHz   0-25MHz   0-25MHz   0-25MHz   0-25MHz
     Triangle wave
   frequency range
Pulse wave frequency
       range
                       0~6MHz    0~6MHz    0~6MHz    0~6MHz    0~6MHz
   TTL digital wave
   frequency range
                                    6
 Arbitrary frequency
        range
     Pulse width
                        100nS~4000S     50nS~4000S 40nS~4000S 30nS~4000S 25nS~4000S
  adjustment range
Square wave rise time       ≤25ns         ≤15ns         ≤10ns         ≤10ns         ≤10ns
 Minimum frequency
                                                  0.01uHz(0.00000001Hz)
     resolution
Frequency accuracy                                       ±20ppm
                                                      ±1ppm/3hours
 Frequency stability
                                                      ±1ppm/3 hours
    Waveform characteristics
                            Sine、Square、pulse (adjustable duty cycle, precise adjustment of
                        pulse width and period), triangular wave, partial sine wave, CMOS
                        wave, DC level (set DC amplitude by adjusting offset), half wave, full
    Waveform type
                        Wave, positive staircase wave, anti-ladder wave, noise wave,
                        exponential rise, exponential drop, multisonic wave, Symplectic pulse
                        and Lorenz pulse and 60 arbitrary waveforms
    Wave length                                         2048 points
     Waveform
                                                        266MSa/s
    sampling rate
  Waveform vertical
                                                          14-bits
     resolution
                           Harmonic
                                                   ≥45dBc(<1MHz); ≥40dBc(1MHz~20MHz)
       Sine wave          Suppression
                                             7
                      Total harmonic
                                                     <0.8%(20Hz~20kHz,0dBm)
                         distortion
 Square wave and
                        Overshoot                               ≤5%
   pulse wave
                       Duty cycle
    Pulse wave         adjustment                            0.1%~99.9%
                         range
                       Duty cycle
 Partial sine wave     adjustment                            0.1%~99.9%
                         range
  Sawtooth wave         Linearity                      ≥98%(0.01Hz~10kHz)
   Output characteristics
                                              10MHz ≤ Frequency ≤
                      Frequency ≤ 10MHz                               30MHz ≤ Frequency
Sine wave amplitude                                 30MHz
       range
                        2mVpp~20Vpp              2mVpp~10Vpp            2mVpp~5Vpp
                           Frequency ≤ 10MHz               10MHz ≤Frequency ≤25MHz
   Square wave 、
   Triangle wave
  amplitude range
                                2mVpp~20Vpp                         2mVpp~5Vpp
    Amplitude
                                                       1mV
    resolution
    Amplitude
                                                   ±0.5%/5 hours
     stability
                                          8
  Flatness of
                                            ±5%(<10MHz); ±10%(>10MHz)
  amplitude
 Waveform output
    Output
                                                   50Ω±10% (typical)
  impedance
   Protection          All signal outputs can work within 60 when the load is short-circuited.
DC offset
                      Output amplitude > 2V 0.2V <Output Range ≤         0<Output amplitude
     Offset                                         2V                         ≤0.2V
adjustment range
                         -9.99V~9.99V               -2.5V~2.5V              -0.25V~0.25V
  Offset resolution                                      0.01 V
  Phase characteristics
     Phase
                                                       0~359.9o
adjustment range
Phase resolution                                          0.1o
TTL/CMOS output
   Low level                                             <0.3V
   High level                                           1V~10V
                                           9
 Level rise/fall time                                  ≤20ns
External measurement function
                         Frequency
                        measurement                         1Hz~100MHz
 Frequency meter           range
     function
                        Measurement
                                           Gate time 0.01S~10s continuous adjustment
                         accuracy
                         Counting
                                                         0-4294967295
                          range
                         Coupling
 Counter function                                 DC and AC coupling methods
                         method
                         Counting
                                                               Manually
                         method
Input signal voltage                              2Vpp~20Vpp
       range
    Pulse width
                                    0.01us resolution, maximum measurable 20s
   measurement
Period measurement                  0.01us resolution, maximum measurable 20s
    Sweep function
  Sweep channel                                   CH1 or CH2
    Sweep type                           Linear sweep, logarithmic sweep
                                          10
   Sweep time                                     0.1s~999.9s
                           Any setting between the maximum output frequency of the
  Setting range       corresponding model of the starting point (0.01Hz) and the end point
                                        Forward, reverse and round trip
 Sweep direction
Bursting function
Number of pulses                                  1-1048575
                       Manual burst, CH2 burst, external burst (AC), external burst (DC)
   Burst mode
General specifications
    Display        Display type                2.4 inch TFT color LCD display
                    Quantity                                100
 Store and load
                                    00 to 99 (00 memory location parameter is loaded by
                     Position
                                                   default as power on)
 Arbitrary wave     Quantity      1 to 60 total 60 groups (15 groups by default as power on)
                    Interface
                                                   USB to serial interface
                      mode
   Interface
                    Extension      With TTL level mode serial interface for user secondary
                    interface                          development
                                         11
                  Communicat
                                                 Adopt standard 115200bps
                   ion speed
                   Protocol         Using the command line, the protocol is made public
                    Voltage
Power supply                                             DC5V±0.5V
                     range
Manufacturing     Surface mount technology, large-scale integrated circuits, high reliability,
 technology                                  long service life
 Prompt tone                     Users can turn on or off by setting program
  Operating
                               All key operations, knob continuous adjustment
characteristics
Environmental
                                   Temperature: 0~40 oC Humidity: <80%
  conditions
                                         12
          Chapter II Instrument Description
1, The front panel overview
                              13
2, The display interface description
                                14
3, The key function description
     Item
                     Instructions
 Function soft   Function soft-key activates the corresponding function on the screen
    keys
                 Press       button to display main interface or waveform selection and
                 cancel
                 Fast switching between measurement mode interface and main interface
                 Fast switching between modulation mode interface and main interface
                 Fast switching between system setting interface and main interface
                 The main interface is used to control the simultaneous output of channel 1
                 and channel 2, and in other interface,      key is used to control
                 (ON/OFF).
                 When setting parameters, you can use left and right keys to move the
                 cursor position.
                 Select the CH1 channel to control the output of CH1, long press to set
                 CH1 as the main display.
                 Select the CH2 channel to control the output of CH2, long press to set
                 CH2 as the main display.
                                            15
ChapterIII Instrument Operation Instructions
After power on, first enter the welcome interface and then jump to the language selection
interface. Press the corresponding soft key to select the language and finally enter the
main interface. After you turn on the computer again, you do not need to repeat the
language selection and go directly to the main interface.
1, Set the parameters
             欢迎界面     in the main interface and output
                               语言选择界面
waveform
    ➢    Press       button to turn the output on or off simultaneously for both channels.
    ➢    Output channel selection: The front panel        ,       keys are used to switch
         the currently selected channel (CH1 or CH2). Pressing          ,      keys again
         in the currently selected channel can turn on/off the output of the channel, and
         long press to place the current channel on the main display of the screen.
         (upper part).
    ➢    Set the waveform: press the front panel        key to activate the waveform
         switching of the current channel. In the active state of the waveform, the knob
         can be quickly switched, and the direction key              can be used to quickly
         switch between the arbitrary waveform and the preset waveform.
    ➢    Set Frequency: Press the soft key         to highlight the “Frequency” parameter.
         At this time, use the direction keys             to move the cursor to select the
         bit to be edited. Then turn the knob to change the value. Press and hold the soft
         key      to change the frequency unit (MHz, KHz, Hz, mHz). , uHz).
    ➢    Press and hold the duty cycle, offset, and phase soft-keys to initialize to
         default values.
  2, MEAS measurement mode interface parameter settings
        Press        and press the soft key          in the measurement mode
interface to switch between the measurement function and the count function.
You can also rotate the encoder to switch.
                                                16
2.1, Measurement function
    The input signal frequency, period, positive pulse width, negative
pulse width, duty cycle and other parameters can be measured, the
measurement frequency range 1Hz-100MHz, the measurement signal
amplitude range is 2mVpp-20Vpp, the input interface is Ext.IN;
   ➢   Coupling setting: Press       to switch the coupling mode to AC or DC.
   ➢   Gate time setting: Press       to set the gate time (0.01S-10S), use the arrow
       keys to move the cursor to select the bit to be edited, then turn the knob to
       adjust the value.
   ➢   Measurement mode setting: Press           to switch between the two options of
       counting frequency and counting period via the encoder.
   ➢   Measurement parameters: frequency, period, positive pulse width, negative
       pulse width, duty cycle.
2.2, Counting function
   The period number of the input signal can be calculated in real time
   ➢   Coupling setting: Press       to switch the coupling mode to AC or DC.
   ➢   After setting all the items, press the soft key    to start the counting function
       and press the key       to stop.
 3,MOD modulation mode interface parameter settings
   ➢ Press          to enter the modulation mode, press the soft key                in
       the modulation mode interface to switch between the sweep function
       (CH1 channel / CH2 channel), pulse function (CH1 channel) and burst
       function (CH1 channel).
  3.1, Sweep function
     Sweep frequency, you can set any starting point frequency and
end point frequency in the signal generator output frequency range,
sweep time 0.1s~999.9s, sweep type is linear scan, logarithm scan two
scan methods, sweep frequency direction is positive , Reverse and
Round Trip Three Sweep Directions;
                                              17
   ➢    In the sweep function (CH1 channel), press the soft key              to select the
        starting point frequency, end point frequency, sweep time, sweep direction and
        sweep mode. After the item is highlighted, use the arrow keys (or press the soft
        -key        ) and the knob to edit the item's parameters.
   ➢    After setting all the items, press the soft key     to start the sweep function and
        press the key       to stop.
   3.2, pulse function
        You can adjust pulse wave pulse width and pulse period time
digitally, which is more accurate than adjusting the duty cycle;
   ➢    In the pulse function (CH1 channel), press the soft key             to select the
        pulse width, period, offset, and amplitude. After this item is highlighted, edit the
        item parameters by pressing the arrow keys (or press the soft key           ) and
        rotating the knob. , pulse width and period units can be switched between ns
        and us by pressing the key          when the item is highlighted.
   ➢    After setting all the items, press the soft key     to start the sweep function and
        press the key       to stop
   3.3,Bursting function
       The pulse train can be set to output 1-108575 periods. The burst
mode is divided into internal CH2 channel bursts, external input signal
bursts, and manual bursts. It should be noted that the period time of the
burst train is less than the burst signal period time.
   ➢    In the burst function (CH1 channel), press the soft key             to select the
        number of pulses and the burst mode. After this item is highlighted, use the
        arrow keys (or press the soft key        ) and the knob to edit the item
        parameters.
   ➢    After setting all the items, press the soft key     to start the sweep function and
        press the key       to stop.
                                                18
  4,System settings and interface parameter settings
        Press the key       to enter the system setting interface. Press the soft key
         to select the parameters for the in/out position, sound setting, brightness
adjustment, language setting, synchronization function setting, and arbitrary wave display
quantity setting.
     ➢ Call Out & Save: Save/recall the current waveform parameters to the specified
          position, rotate the knob to adjust to the specified position. Press the
          corresponding soft key when you want to recall, save, or clear.
     ➢ Sound settings: Sounds can be turned on and off with keys               、      .
     ➢ Brightness adjustment: Brightness adjustable from 0 to 12 levels can be quickly
          adjusted by rotating encoder.
     ➢ Language setting: Available by pressing                 、       to select English
          and Chinese display.
     ➢ Synchronization: The CH1 channel is used as the operation target during
          synchronization. The parameters of the CH2 channel change following the CH1
          channel parameters. When the synchronization item is highlighted, press the
          key              or rotate knob to select the item to be synchronized (frequency,
          waveform, amplitude, duty cycle, offset), press the soft key          to select it, and
          press the soft key       to cancel.
     ➢ Arbitrary waveform number setting: The number of arbitrary waveforms of the
       main interface waveform can be quickly adjusted by rotating the encoder (1-60).
    ➢    starting point frequency, end point frequency, sweep time, sweep direction and
         sweep mode. After the item is highlighted, use the arrow keys (or press the soft
         -key        ) and the knob to edit the item's parameters.
    ➢    After setting all the items, press the soft key       to start the sweep function and
         press the key         to stop.
    3.2, pulse function
    ➢    In the pulse function (CH1 channel), press the soft key              to select the
                                                 19
         pulse width, period, offset, and amplitude. After this item is highlighted, edit the
         item parameters by pressing the arrow keys (or press the soft key               ) and
         rotating the knob. , pulse width and period units can be switched between ns
         and us by pressing the key          when the item is highlighted.
    ➢    After setting all the items, press the soft key       to start the sweep function and
         press the key       to stop
    3.3,Bursting function
    ➢    In the burst function (CH1 channel), press the soft key              to select the
         number of pulses and the burst mode. After this item is highlighted, use the
         arrow keys (or press the soft key         ) and the knob to edit the item
         parameters.
    ➢    After setting all the items, press the soft key       to start the sweep function and
         press the key       to stop.
4,System settings and interface parameter settings
        Press the key       to enter the system setting interface. Press the soft key
         to select the parameters for the in/out position, sound setting, brightness
adjustment, language setting, synchronization function setting, and arbitrary wave display
quantity setting.
     ➢ Call Out & Save: Save/recall the current waveform parameters to the specified
          position, rotate the knob to adjust to the specified position. Press the
          corresponding soft key when you want to recall, save, or clear.
     ➢ Sound settings: Sounds can be turned on and off with keys              、      .
     ➢ Brightness adjustment: Brightness adjustable from 0 to 12 levels can be quickly
          adjusted by rotating encoder.
     ➢ Language setting: Available by pressing                、        to select English and
          Chinese display.
     ➢ Synchronization: The CH1 channel is used as the operation target during
          synchronization. The parameters of the CH2 channel change following the CH1
          channel parameters. When the synchronization item is highlighted, press the
          key              or rotate knob to select the item to be synchronized (frequency,
          waveform, amplitude, duty cycle, offset), press the soft key         to select it, and
                                                 20
    press the soft key   to cancel.
➢ Arbitrary waveform number setting: The number of arbitrary waveforms of the
  main interface waveform can be quickly adjusted by rotating the encoder (1-60).
                                       21