CAREEX-6(T)
HEAD OFFICE, NORWAY ENGLAND GERMANY USA
DNH AS DNH WW Ltd DNH GmbH DNH Speakers Inc
Phone................... + 47 35 98 56 00 Phone……. + 44 1908 275 000 Phone… + 49 040 6569 30-0 Phone........... + 1 484 494 5790
E-mail...………............ dnh@dnh.no Fax.............+ 44 1908 275 100 Fax....... + 49 040 6569 30-30 Fax…........... .+ 1 484 494 5793
Web-Site…………….. www.dnh.no E-mail…..........dnh@dnh.co.uk E-mail...........…. dnh@dnh.de E-mail..dnh@dnhspeakers.com
ISO 9001 CERTIFIED
100 Volt transformer
Primary connections
1:2 6,0 W
2:3 3,0 W
3:4 1,5 W
1:3 1,0 W
Standard model delivered with two M20
Ex approved plastic blinding plugs 2:4 0,5 W
1:4 0,3 W
Certified by/ Certification code / Number: NEMKO / EEx de IIB+H2 T6 Gb/ Nemko 10 ATEX 1054
IECEx NEM 11.0016 II 2 G
Sound pressure levels at 1W/1m Specifications
Material / Color Aluminum / Anodized
Mounting Foot Bracket
Termination e-chamber, screw terminals
Weight w/transformer 3,6 kg
IP-rating (e-chamber) 54
Max. / min. amb. temp 40°C / -20°C
Rated / max. power 6 W / 15 W
SPL 1W/1m 90 dB
SPL rated power 97 dB
Effective freq. range 160 – 16000 Hz
Dispersion (-6dB) 1kHz / 4kHz 200° / 40°
Directivity factor, Q 1kHz 1,8
Options Impedances, labels
Installation, Operation and Maintenance Procedures
Fasten loudspeaker to wall or ceiling with four screws by use of the extruded aluminum brackets on each side.
Enter the e-chamber by loosening the screws on the lid and terminate the cable in the screw terminal.
Fasten lid screws with a torque of 2 – 2,2 Nm to assure the IP rating.
For optimum performance, always use the correct voltage / power and operate within the frequency limits as
stated.
Use only certified/specified cable glands and blanking plugs.
Standard model delivered with two M20 Ex approved plastic blinding plugs.
Do not open loudspeaker when energized.
Ex-loudspeakers must be earthed correctly using the specially marked screws.
This loudspeaker is supplied with two years warranty against defective workmanship.
DNH reserves the right to alter specifications without notice.
https://dnhas.sharepoint.com/sites/Teknisk/Dataark/Ex_EEx/Cabinets/CAREEX-6(T).doc Rev. 05.03.2024