0% found this document useful (0 votes)
378 views1 page

Lound Speaker Ex

This document provides product specifications and installation instructions for the DNH DSP-25 EExmN(T) explosion proof loudspeaker. Key details include: - The loudspeaker has a 100V line with multiple voltage tappings and a transformer, is ATEX and IECEx certified for use in hazardous areas, and has an IP66 rating. - It produces sound pressure levels of 106dB at 1kHz and 102dB at 1kHz at 1W/1m with dispersion of 110 degrees at 1kHz and 30 degrees at 4kHz. - Installation instructions specify fastening the bracket securely, using the correct voltage and frequency range, only certified cable glands

Uploaded by

Mihai Matei
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
378 views1 page

Lound Speaker Ex

This document provides product specifications and installation instructions for the DNH DSP-25 EExmN(T) explosion proof loudspeaker. Key details include: - The loudspeaker has a 100V line with multiple voltage tappings and a transformer, is ATEX and IECEx certified for use in hazardous areas, and has an IP66 rating. - It produces sound pressure levels of 106dB at 1kHz and 102dB at 1kHz at 1W/1m with dispersion of 110 degrees at 1kHz and 30 degrees at 4kHz. - Installation instructions specify fastening the bracket securely, using the correct voltage and frequency range, only certified cable glands

Uploaded by

Mihai Matei
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DSP-25 EExmN(T)

N-3770 Krager
DNH WW Ltd. Phone:.(44) 1908 275 000 DNH GmbH Phone:...(49) 040 6569 30-0
NORWAY England Fax:..(44) 1908 275 100 Germany Fax:...(49) 040 6569 30-30
Phone: ........ (47) 35 98 56 00 E-mail:dnh@dnh.co.uk E-mail:dnh@dnh.de
Fax: ............ (47) 35 98 56 10
DNH Phone:.(1) 484 494 5790
E-mail: .............. dnh@dnh.no
Speakers Inc. Fax:..(1) 484 494 5793
Web-site: ....... www.dnh.no USA E-mail:dnh@dnhspeakers.com
ISO 9001 CERTIFIED

Transformer:
100 V line (optional 70V, 50V)

Primary nominal tappings:


1:2 25,0 W
2:3 12,5 W
3:4 6,0 W
1:3 4,0 W
2:4 2,0 W
1:4 1,0 W

Cable diameter: 1 x M20 plastic EEx


10 15 mm ATEX cable gland and
1 x M20 EEx Atex
blinding plug

II 2 GD
Certified by / Certification code / Number: NEMKO / EEx dem IIB+H2 T5 / 01 ATEX 235
Certified by / Certification code / Number: NEMKO / EEx dem IIC T5 / 01 ATEX 235

Sound pressure levels at different frequencies at 1W/1m sine


wave IIB IIC
Material / Color ............... Anti-static polyamide / Black
Mounting ....................................................... Bracket
Termination ...................... e-chamber, screw terminals
Weight w/ transformer .....................................4,0 kg
IP-rating............................................................... 66
Max / min amb temp ............................ 55 C / -53 C
Rated / max power ................................ 25 W / 25 W
SPL 1W/1m ................................................... 106 dB 102 dB
SPL rated power ............................................ 117 dB 113 dB
Effective freq range ..............................370 7000 Hz 400-7000
Dispersion (-6dB) 1kHz / 4kHz..................... 110 / 30 100 / 30
Options.Impedances, moulded permanent cable, labels

Installation, Operation and Maintenance Procedures

When mounting the loudspeaker please ensure that it is re-assembled in the same manner in which it was
received. Fasten bracket with 2-3 screws.
To change the position of the loudspeaker, please adjust the bracket (by loosening / tightening the screws) as
required.
For optimum performance, always use the correct voltage / power and operate within the frequency limits as
stated.
Use only certified/specified cable glands and blanking plugs.
Do not open loudspeaker when energized.
Fasten lid with a torque of 1 - 2 Nm.
This loudspeaker is supplied with a 2 year warranty against defective materials and workmanship.

DNH reserves the right to alter specifications without notice. Rev. 03.02.2010