2/13
CAGI Refrigerated Compressed Air Dryer
Performance Verification Program
Participant Directory
2/13
Overview
The Compressed Air and Gas Institute (CAGI) sponsors the Performance Verification
Program for Refrigerated Compressed Air Dryers. The program provides a uniform and
commercially practical means of verifying participants’ claimed ratings. Compliance
with the provisions of the latest edition of ISO 7183, Compressed Air Dryers-
Specifications and Testing, is mandatory for all participants.
Participation in the Program is voluntary and is open to all manufacturers of standalone
refrigerated compressed air dryers from 200 – 1000 SCFM. On a regular and random
basis, the Program Administrator, Intertek Testing Services, selects and tests samples of
equipment to verify that actual performance meets the manufacturer’s certified published
performance ratings.
The ratings certified under this Program are displayed on datasheets published on
participants’ websites in the standard CAGI datasheet format and in the participants
published literature. The verification seal, which appears on units and on participants’
published literature, is the participants’ public representation that the stated performance
of the participants’ equipment has been verified by an independent laboratory.
The flow and outlet pressure dew point ratings in this directory are provided along with
model number only to help identify the specific model that was tested by the
administrator. Consult a copy of the manufacturer’s data sheet for more detailed
information. Datasheets can be located via the following links:
• Atlas Copco
HU UH
• domnick hunter
HU U
• Ingersoll Rand
HU U
• SPX
HU U
• Zeks
HU U
2/13
Participant List
The following manufacturers of refrigerated compressed air dryers are currently
participating in the CAGI Performance Verification Program. Click on the manufacturer
name to see the results of the tests that have been conducted for that manufacturer.
Atlas Copco
HU U
domnick hunter
HU U
Ingersoll Rand
HU UH
SPX
HU U
Zeks
HU U
2/13
Atlas Copco Performance Verification Test Results
0B
Rated Outlet
Model Number Rated Flow Result
Pressure Dew Point
FD 185 360 39 Passed
FD410A 869 39 Failed
FD310A 657 39 Failed
Failed and
FD150 297 39
Re-rated
Failed and
FD220 466 39
Re-rated
Back to Overview
Back to Participant List
2/13
domnick hunter Performance Verification Test Results
Rated Outlet
Model Number Rated Flow Result
Pressure Dew Point
DRD400 400 44.5 Passed
DRD500 500 39.6 Passed
DRD265 265 40.9 Passed
DRD325 325 42.9 Passed
DRD700 700 40.2 Passed
Failed and
TMS0400-A4 400 39
Re-rated
Failed and
DRD500 500 39.6
Re-rated
Back to Overview
Back to Participant List
2/13
Ingersoll Rand Performance Verification Test Results
Rated Outlet
Model Number Rated Flow Result
Pressure Dew Point
TS2A 295 39 Passed
TS4A 525 39 Passed
D8501NA400 500 39 Passed
Failed and
NVC600A400 600 43.7
Re-rated
D6801NA400 400 42.7 Passed
NVC500A400 500 41.7 Passed
Back to Overview
Back to Participant List
2/13
SPX Performance Verification Test Results
Rated Outlet
Model Number Rated Flow Result
Pressure Dew Point
HPRP500-460 500 42 Passed
HPRP400 400 42 Passed
Failed and
FPRP600 600 44
Re-rated
HPRP300 300 40 Passed
FPRP500 500 44 Passed
Back to Overview
Back to Participant List
2/13
Zeks Performance Verification Test Results
Rated Outlet
Model Number Rated Flow Result
Pressure Dew Point
500HSFA400 500 39 Passed
400HSGAS400 400 39 Passed
500NCEA400 500 39 Passed
600NCEA400 600 39 Passed
400HSGA400 400 40.7 Passed
500HSFA400 500 41.7 Passed
Back to Overview
Back to Participant List