Mont 30
Mont 30
Door Controller
Starting Guide
V1.0   2023.06
                                FOREWARD
Before using the product, please read through this user manual carefully.
In addition, please do not use this product until you have fully understood
safety precautions.
Note:
• Preserve this manual for future.
• If you need the user manual due to damage, loss or other reasons,
   please contact distributors of our company or directly contact our
   Technical Service Center.
• If you still have some problems during use, please contact with our
   Technical Service Center.
• Due to product upgrade or specification change, and for the purpose of
   improving convenience and accuracy of this manual, this manual’s
   contents may be modified.
MONT30 Features
Ultra small size       Over 50% smaller than the industry average.
                       Support CAN communication, only use 2 cables to realize control
CAN Communication
                       commands.
                       One-button start self-learning, knobs set speed and torque, fast and
Easy to debug
                       efficient.
Mobile phone debug     Onboard Bluetooth module, support Android phone APP debugging.
Silent running         Carrier frequency up to 16kHz, silent and noiseless running.
Record Blocked Point   Automatic record the CD blocked point to avoid the second impact.
Flexible upgrade       OTA upgrade software to quickly solve technical problems on site.
Safe and reliable      Automatically resets common faults to ensure service continuity.
                 Version and Revision Records
Time: 2023/06
Version: V1.0
Chapter     Contents
                • V1.0 version released.
                                  Safety Information
Safety Definition
    Pay attention to contents with following marks in the user manual or on the product.
                                                  Danger
    Danger: A Danger contains information which is critical for avoiding safety hazards.
                                                  Warning
    Warning: A Warning contains information which is essential for avoiding a risk of damage to
    products or other equipements.
                                                    Note
    Note: A Note contains information which helps to ensure correct operation of the product.
Professional Personnel
   Only qualified electrical engineer can perform electrical wiring.
   Only a trained and authorized professional person can maintain the product.
                                                     Contents
1. Check Product ......................................................................................................... 1
       1.1 Model ............................................................................................................ 1
       1.2 Layout ........................................................................................................... 1
4. Power on ................................................................................................................ 9
5. Debugging ............................................................................................................ 10
       5.1 Debugging Preparation................................................................................. 10
            5.1.1 Confirm Debugging Process ............................................................................ 10
            5.1.2 Description of Indicator, Button, Knobs, and DIP Switches ............................... 10
            5.1.3 Self-learning Related Parameters.................................................................... 12
       5.2 Motor Self-learning ...................................................................................... 13
       5.3 Door Width Self-learning (Only Distance Control) ........................................... 14
       5.4 Debug OD and CD......................................................................................... 15
1. Check Product
1.1 Model
                                       MT30-5A
                                           1           2
   Code      Description
   1         Product series   • MT30: MONT30 door controller
             Product          • 5A-EN: ABZ encoder, power supply 5V
   2
             configuration    • IN: High bus voltage
1.2 Layout
             Indicator
            YL: Yellow
            GN: Green
               RD: Red                                                    Barcode
                  Knob
          Adjust speed
           and torque                                                     Nameplate
Button
                                                                                               1
MONT30 Starting Guide V1.0
2. Mechanical Installation
    Note:
    If you open the package and find that the door controller is incomplete or damaged,
    please do not install the door controller.
    Note:
    1. Confirm the running temperature between -10 - +40℃. Installing in well-ventilated
        places can improve the running reliability of the door controller.
    2. If the running temperature exceeds 40°C, the door controller needs to be derated by 2%
        for every 1°C increase. The Max. running temperature is 50°C.
2
                                                               MONT30 Starting Guide V1.0
                                    110
     unit is mm.
                                           4-Φ5
                                                         170
                                                                                       3
MONT30 Starting Guide V1.0
3. Electrical Installation
                                                   Danger
     • Only qualified electrical engineer can perform electrical wiring.
     • MONT30 must be reliably powered off for 10 minutes before wiring.
     • MONT30 has a leakage current of more than 3mA to ground, depending on the use conditions.
       To ensure safety, MONT30 and the motor must use independent ground cables, and recommended
       to install B-type residual current devices (ELCB/RCD).
     • When MONT30 is charged, do not touch the wiring terminal of MONT30.
     • Do not short circuit between power terminals.
                                                  Warning
     • Do not do dielectric strength test on MONT30.
     • Connect the terminals firmly.
     • Prohibit on-off contactors to start and stop MONT30.
     • Do not connect the input power to U/V/W terminals of MONT30.
     • Do not connect the phase-shifting capacitors to the output circuit.
     • Confirm the AC input power supply voltage is the same as rated input voltage of MONT30.
L, , N
, U, V, W
4
                                                                                   MONT30 Starting Guide V1.0
   OD, COM            Open door command input         Isolation, support dry contact and NPN input, low level
                                                      is valid
   CD, COM            Close door command input         • Input impedance: 4.7kΩ
   DI1 - DI6,                                         • Input Max. frequency: 1kHz
                      Digital input
   COM                                                DI1 - DI6: F06.03 - F06.08 set function, NO or NC input
   +24V, COM          +24V power supply               +24V power supply, the Max. output current is 200mA
                                                                         PGP, GND, PE
                                                                         A, B, Z
                                                                         CS, CK, SO
                                                                                                                5
MONT30 Starting Guide V1.0
6
                                                                                  MONT30 Starting Guide V1.0
                                                                                                          7
MONT30 Starting Guide V1.0
                        OD speed          CD speed
                         change            change
                          signal            signal
              OD limit signal                  CD limit signal
                                      Figure 3-6 Install the travel switch
Wiring
            Single                L
            phase
           220VAC                 N                                    External
                                                        RJ45
                                                                       keypad
                                                                                     Elevator
                                                                                  control system
                                  U                             Open the door     Y1
                                           MONT30        OD
                 M                V
                                                                Close the door    Y2
                                                          CD
                                  W
                                                       COM
                                                                                  CM1
                                                                Door position
                                                         PA     output
           Door open change                                                       P24
           speed NC                                       PB
                                  DI1                                              X3
           Door open limit NC                                   Door open arrived
                                  DI2
           Door close change                            DOA     output
                                                                                   X1
           speed NC                                             Door close arrived
                                  DI3                   DC A    output
           Door close limit NC                                                     X2
                                  DI4                   CME                       P24
                                  COM
           NC: Normally closed
                                 Figure 3-7 Speed control wiring (default)
8
                                                                                   MONT30 Starting Guide V1.0
                                                   External controller
                              DI2                                        DI2
                                         Dry                                       NPN
                              DI3    contact                             DI3
DI4 DI4
COM COM
4. Power on
                                                  Danger
   • After Power Switch is set to OFF, the power input 220V terminal still has high voltage.
     Before disconnecting the external power supply, forbidden to touch, plug in or pull out the 220V
     terminal, otherwise there is a danger of electric shock.
  Power Switch is set to ON, the indicator is always on (green or yellow), and the MONT30
  is in stand-by state.
                         Indicator (green or yellow, keep on)             Power
                                                                          Switch
                                                                            ON
                                                                            OFF
                                                                                                           9
MONT30 Starting Guide V1.0
5. Debugging
Indicator
Knob
Button
DIP switch
10
                                                                         MONT30 Starting Guide V1.0
                          Table 5-3 Display or operating description
Display or Operate                  Description
                                    Displays yellow, red, green, and the status description are
                                    shown in the table below.
                                     Display         Keep On                Flash
                                                     Door arrived           Door command
Indicator                            Yellow (YL)
                                                     (open / close)         (open / close)
                                                                            In normal run model
                                     Green (GN)      Stand-by
                                                                            or motor learn model
                                     Red (RD)        Failure                Bluetooth connected
                                   123
                                    Debug the holding torque of door open or close arrived, there
                                    are 20 gears in total.
                         Hold
                                    • Default middle gear. Adjust 2% per gear. Adjust the knob to
                         Torque
                                      the left, the torque decreases, otherwise the torque
                                      increases.
                                    Debug the reopening torque when the door is blocked during
   Hold        Open
  Torque       Speed                closing the door, there are 20 gears in total.
                         Reopen
                                    • Default middle gear. Adjust 2% per gear. Adjust the knob to
                         Torque
                                      the left, the torque decreases, otherwise the torque
                                      increases.
  Reopen       Close
  Torque       Speed                When F10.23 hundred = 1, select the gear, 4 gears in total.
                         Open
                                    When F10.23 hundred = 0 [default], fine tune the 4th gear OD
            Knob         Speed
                                    speed.
                                    When F10.23 hundred = 1, select the gear, 4 gears in total.
                         Close
                                    When F10.23 hundred = 0 [default], fine tune the 4th gear CD
                         Speed
                                    speed.
                                    • DIP switch S1&S2 = ON&ON, press Button for 1s and release
                                      button to start motor learn.
                                    • DIP switch S1&S2 = OFF&ON, press Button for 1s and release
Button
                                      button to start width learn.
                                    • DIP switches S1&S2 = ON&OFF, long press Button to test the
                                      OD and CD effect.
                                    • S1&S2 combination setting function, as shown in the table
                                      below.
                                         S1         S2           Function
     S S S S
     1 2 3 4                             OFF        OFF          Normal Run Mode [default]
                   ON                    ON         OFF          Trial Run Mode
                                                                                                    11
MONT30 Starting Guide V1.0
12
                                                                               MONT30 Starting Guide V1.0
                                                                                                           13
MONT30 Starting Guide V1.0
14
                                                                       MONT30 Starting Guide V1.0
                                                                                               15
MONT30 Starting Guide V1.0
                      Table 5-5 The corresponding parameters of the four gear OD curve
                                        1st Gear         2nd Gear                           4th Gear
     OD Curve                                                             3rd Gear
                                        F03.01 -         F03.07 -                           F03.19 -
     Group F03                                                            F03.13 - F03.18
                                        F03.06           F03.12                             F03.24
     OD start distance (distance)       300 pulse        300 pulse        300 pulse         300 pulse
     OD start time (speed)              300ms            300ms            300ms             300ms
     OD start speed                     2.50Hz           3.00Hz           3.50Hz            3.50Hz
     OD Acc. time                       1.0s             1.2s             1.3s              1.4s
     OD high speed                      10.00Hz          15.00Hz          20.00Hz           24.00Hz
     OD Dec. time                       1.4s             1.6s             2.0s              2.0s
     OD creep speed                     2.00Hz           2.50Hz           3.00Hz            3.00Hz
     Set DIP switch S1&S2 = OFF&OFF (normal run mode), confirm F00.03 = 1 (terminal
     control), then connect to the elevator control system.
16