LC2005 BA Lift Control
LC2005 BA Lift Control
Issued 01.2007
Document-No. 300.000.040
Index
                                                                                                                                                                      I
Display and Operation
                                                                                                        LON                                                                    RESET
                                            PROGRAMM LON
                    -A1
                                                                                                                                                                                                                         X8 RS422
                                                                                                            MC3000-CPU                              173.033.015
      X5 SSI-IN
                                                                                                                                                                                                     Aussen-
                                                                                                                                                                                                    steuerung                       Switch for external
                                                                                                                      +                :Parameter                                                                 EIN
                                                                                                                      +                :Statusanzeige
                                                                                                                                                                                                                  AUS               control
                                                                                                                                                                                                      Fehler
                                                                                                                                                                                                     löschen
PROGRAMM ODD
                                                                                                                                                                                                ?
      X9 RS232
PROGRAMM EVEN 5V
                                  A5
              A1
A4
                                       A6
      X10 RS232
24V E/ A
                                                                        RUN
                                                                                                                                                                                                                        X1
                                                                                                                                                                                                                        24 V
                                            K1
                                                                                                                                       GN D
                                                                              E1
                                                                                   E2
                                                                                        E3
                                                                                             E4
                                                                                                  E5
                                                                                                       E6
                                                                                                            E7
                                                                                                                 E8
                                                                         K1
                                                                                                                                                         24V
                                                                                                                                                                                                                    GN D
                                                                                                                      A1
                                                                                                                                                               X3                          X2                            PE
                             X4
                                                                                                                                                                         LC-display 4
                                                                                                                                                                         4 x 20 characters
                                                                                                                                                                                                                                                          1
Display and Operation
Encoder
                          >+<
                         <   >
                             >+<
                            <   >           >+<
                                             <   >
                            R: - v: 0,0 m/s    +
       Encoder/Positio      Car   : 00016549 mm
       nstatus              Offset:-00657858 mm
                            Pos. :-00641308 mm
                             >+<
                            <   >           >+<
                                             <   >
                                                   >+<
                                                  <   >
2
Display and Operation
 No.       Meaning
  1        Program flow control: with the program running, the marks ”+” and ”∗” are alternatingly displayed in
           intervals of a second.
  2        Indication of the active operation mode:
           NORMAL                           Normal mode, additional information will be displayed:
                 SFTY OPEN                  Safety circuit open
                 LockgFaultAuto             Self locking fault in NORMAL operation
                 LockgFaultInsp             Self locking fault in INSPECTION/EMERGENCY EL. CONTR.
                 OVERLOAD                   Overload
                 CAR LIGHT                  Car light OFF
                 SFTY-DOOR                  Safety circuit DOOR OPEN
           EXTCONTROL. OFF                  External control is disengaged
           EM.EL.OP.                        Operating mode EMERGENCY ELECTRICAL OPERATION
           INSPECTION                       Operating mode INSPECTION
           CONTROL+LIGHT OFF                Operating mode control/light off
  3        Current car position
  4        Destination landing of the current trip
  5        Speed of car [m/s]
  6        Deviation [mm] of car stopping position from accurate level position
  7        Indication of travelling direction:
            — no travelling direction
             travelling direction upward
             travelling direction downward
 8+9 Door status TV (front door) and TH (rear door):
     []door open
     ][door closed
     -- door control disengaged, doors are closed
  10       *** LC2005 ***
                  resp.
           F-No 1104 L06       Fault no. and landing. By repeated operating of key <? > the clear text
                          fault indication can be switched on and off. Automatic switching-off will be
                    made after 20 sec.
  11       Number of elevators in a group (in case of group only)
                                                                                                                   3
Display and Operation
    No.      Meaning
     1       Program flow control: with the program running, the marks ”+” and ”∗” are alternatingly displayed in
             intervals of a second.
     2       Speed [m/s]
     3       Travelling direction:       —            no travelling direction
                                                     travelling direction upward
                                                     travelling direction downward
     4       Position of car [mm]
     5       Offset [mm]
     6       Location value from encoder [mm]
4
Display and Operation
                            8             1
      2        *** LC 2005 *** +
             26.10.96 11:07:41
                                          3
             T0000022 O000002h            5
      4
             C0000024 M000000h
      6                                   7
No. Meaning
  1       Program flow control: with the program running, the marks ”+” and ”∗” are alternatingly displayed in
          intervals of a second.
2+3 Date/Time
4 Trip counter
                                                                                                                 5
Display and Operation
          2                                 1
                 Main menu              ↓
          3      >Drive
                  shaft
                  Door parameters
          4
No. Meaning
    1     Navigation assistance; indicates to which direction the list with the selectable submenues can be
          scrolled through:
                   Not all submenus can be shown at the same time on the display.
                    The double arrow indicates that the list can be scrolled in both directions.
                   The end of the list is reached, only upward scrolling is possible.
                   The begin of the list is reached, only downward scrolling is possible.
              Main menu             ↓
              >Drive
               Shaft
               Door parameters
6
Display and Operation
Menu-display Parameter-display
Display-mode Input-mode
<↵> or <>
                                          The <↵↵ > key allows to change from display mode into setting
                                          mode. The parameter can be modified with < >
                                          resp. <
                                                  >the cursor position – mark _ shows, which digit of the
                                          parameter is going to be modified. The cursor can be moved with
                                            > resp. <
                                          <            >.
                                          After completed setting the modification of parameter is to be
                                                          ↵ >, the display changes automatically back to the
                                          confirmed with <↵
                                          menu.
                                          With key <  > the parameter setting will be quit without modifying
                                          the parameter values.
                                                                                                             7
Display and Operation
Menu-display Parameter-display
Display-mode Setting-mode
                                                Landing:        03
                                                Pos[mm]: 004801
                                                Side:    DF_VB
                                                Text: 1 Knd: NORM
                                                  <↑>             <↓>
                                    <→>                                        <↵>
           Shaft                               Landing:        02                     Landing:        02
            LDG switchg.points                  Pos[mm]: 001826                        Pos[mm]: 001826
            Terminal landing                    Side:    DF_VF                         Side:    DF_VF
           >LDG description                     Text: 0 Knd: NLD_T                     Text: 0 Knd: NLD_T
                                    <←>                                         <↵>
                                                  <↑>             <↓>           or
                                                                                <>
                                                Landing:        01
                                                Pos[mm]: 001500
                                                Side:    RD_RV
                                                Text:-1 Knd: NLD_B
                                               The list of the parameter sets can be scrolled through in the display
                                               mode with the keys <  > resp. < >.
                                               Parameter modification is done analogous to the parameter view
                                               with only one window. When the parameter input is completed, the
                                               parameter display mode is shown.
1.3.5 Dialogues
                                               With some parameters, e.g. Shaft teach in, a dialogue can be
                                               activated. In order to start the dialogue in the parameter setting
                                               mode OK is to be selected. The dialogue shows instructions and
                                               the user is requested to press certain keys.
                                                                                      P +0000000 R00
                                                Shaft teach-in
                                                                             <↵ >     Zone F1 R0 Di-
                                                start:   OK                           teach-in compl ?
                                                                                      Press E-key
8
Display and Operation
Key Meaning
                                                                                                              9
Fault diagnosis
2     Fault diagnosis
                        With LC2005, depending on the character of fault, information
                        about the fault can be obtained at various places.
                        Display and fault memory of the CPU-card:
                        Here you should investigate first. Depending on the displayed fault,
                        further information can be obtained (see page 10 chapter 2.1 Fault
                        diagnosis at the CPU-card).
                        Lettered LEDs of the pre-control card;
                        These are indicating the condition of the safety circuit and of the
                        contactors/valves (see chap. Precontrol card).
                        In case of faults in the bus-modules, with faulty bus
                        communication, information can be obtained at the status-LED.
                        Diagnosis of the bus modules).
                        Input/output signals of the CPU can be evaluated by means of
                        LED-displays (see chap. CPU board)
2.1     CPU-board
                        If there is a fault during operation the display shows the fault-
                        number. Simultaneously the fault is saved in an error memory
                        together with further informations about the condition of the control
                        at occurrence of the fault.
                           Serious fault:
                             st
                            1 digit of the fault identification no. = 1
                           Warnings or temporary faults:
                             st
                            1 digit of the fault identification no. = 2
                           Fault that must be acknowledged
                             st
                            1 digit of the fault identification no. = 3
10
Fault diagnosis
             Idx: 022    No: 2112    Display of last registered faults, sorted acc.to the time. With keys
             01.01.95    08:15:20    ↑ and ↓ the list of faults can be scrolled through.
             L06 D04     P016543mm
             I00000000   O00000000   With key <?> you can switch over to the plain text fault display and
                                     back again.
             Display:
             Idx                     1…100        Upon jumping to the fault memory display the most
                                                  recent fault with the highest index (=no. of faults) is
                                     displayed.
                                     The fault identification no. consists of the actual 4-digit fault no.
                                     and of a leading 2-digit classification no.
                                     The classification no. is used only in connection with data
                                     transmission to external systems.
                                     In the following, only the 4-digit fault no. as shown in the display
                                     will be used.
                                     As a maximum, only the latest 100 faults will be displayed in the
                                     fault memory.
                                                                                                             11
Fault diagnosis
Hex-display: I: 0 0 3 8 8 0 A 0 O: 0 0 0 1 5 0 3 C
              Binary-display:     |0000|0000|0011|1000|1000|0000|1010|0000
                                      14243
                                      not used
              Bit-number:            31 28   24   20   16   12    8    4         0
12
Fault diagnosis
                                                                                                                                13
Fault diagnosis
14
Fault diagnosis
The windings of the motor have become too hot, signal at - Conductor to motor-thermistors interrupted
                                                                                                                              15
Fault diagnosis
08     2203       Signal MOTOR ON POWER not available.                           - Main contacts of travel contactor open or
                  The motor controller has been activated by the control, but      defective
                  no current flow is getting established, no signal arrives at   - Aux. make-contact on K31 defective
                  X3.8                                                           - Wrong setting at the inverter
                                                                                 - Cables interrupted
08     2204       The breaker of the brake contactor (K32) does not open
                  when activated
08     2205       Checkback: travel contactor (K31) drops during travel.
08     2206       Checkback: travel contactor (K31) not dropped at end of
                  travel
08     2207       FI does not cancel DESTINATION REACHED when starting. With position control only
08     2208       Signal MOTOR ON POWER still available after end of travel      -FI defective
08     2209       Signal MOTOR ON POWER extinguishes during travel               - Wrong settings at the frequency inverter
                                                                                 - Travel contactor shortly opened
                                                                                 - Sequential fault in case of emerg. stop
08     2220       Fault in the program status of internal program faults
08     2221       Fault on sending of INV_ENABLING.                              Only with serial communication to the FI
08     2222       Fault in acknowl. of sending INV_ENABLING:                     Only with serial communication to the FI
08     2223       Fault on sending of CANCEL_INV_STOP.                           Only with serial communication to the FI
08     2224       Fault in acknowl. of sending CANCEL_INV_STOP.                  Only with serial communication to the FI
08     2225       Fault on sending of INVERTER_TIPP_STOP.                        Only with serial communication to the FI
08     2226       Fault in acknowl. of sending INVERTER_TIPP_STOP.               Only with serial communication to the FI
08     1233       Input “brake not open“ not not switching
08     2227       Fault on sending of INV_TIPP_TELEGRAM.                         Only with serial communication to the FI
08     2228       Fault on acknowl. of sending INV_TIPP_TELEGRAM.                Only with serial communication to the FI
08     2229       Fault on sending of INV_SETPOINTVAL_32.                        Only with serial communication to the FI
08     2230       Fault on acknowl. of sending INV_SETPOINTVAL_32.               Only with serial communication to the FI
08     2231       Fault on sending of INV_TIPP_PARAMETER_READG                   Only with serial communication to the FI
08     2232       Fault on acknowl. of sending                                   Only with serial communication to the FI
                  INV_TIPP_PARAMETER_READG.
08     2234       Input “brake not open“ not available
16
Fault diagnosis
                                                                                                                                   17
Fault diagnosis
18
Fault diagnosis
                                                                                                  19
Fault diagnosis
        3
                                                                               = LED on
        4
6 ca. 10s
            0     1   2     3     4       5    6     7     8                                  with 10 MHz
                                                                 t [sec] after switching on
            0     2   4     6     8       10   12    14    16                                 with 5 MHz
                                          All bus modules including the CPU have a service-LED, that gives
                                          information about the modul-status by certain blinking modes.
                                          That, e.g. can be checked, if via the CPU a bus modul cannot be
                                          activated. The service-LED will give information about the status of
                                          the LON-chip:
                                          (with lower pulse frequency the time periods are getting extended
                                          accordingly)
1      LED flashes once after switching on of the voltage LON works normally
       supply (or reset).
2      LED permanently on                                  Hardware-fault
3      LED about 2 sec off (Power On Reset)                Program not configured as autostarting
                                                           (applicationless, should not happen)
4      LED flashes cyclically                              Reset by watchdog-timer: Program waits for
                                                           external event (synchronization with central
                                                           computer) infinite loop in program.
5      LED blinks in intervals of a second                 The node has an application program, however is
                                                           unconfigured; the node must be loaded via
                                                           network (this case really should not happen).
6      LED is about 10 sec off (EEBLANK-EPROM has          EEPROM of LON-chip is erased
       been plugged)
7      LED does not flash after switching on               Hardware-fault
20
Fault diagnosis
Menu structure
                  Main
                   Main menu
                         menu
                        Drive
                        Drive
                        Shaft
                        Shaft
                        Door
                        Door parameters
                             parameters
                        Configuration
                        Configuration
                        Group
                        Group
                        Service
                        Service
                        Commissioning
                        Commissioning
                        Command
                        Command memory
                                memory
                        Password
                        Password
                                          21
Fault diagnosis
                   Drive
                    Drive
                            Driving
                            Driving system
                                    system
                            Setpoint
                            Setpoint value
                                     value output
                                           output
                            Valve
                            Valve output
                                  output
                            Feedback
                            Feedback closed-loop
                                     closed-loop contr.
                                                 contr.
                            Brake
                            Brake pick-up
                                  pick-up time
                                          time
                            Electr.
                            Electr. brake
                                    brake
                            Electr.
                            Electr. braking
                                    braking completed
                                            completed
                            Brake
                            Brake
                                    Brake
                                    Brake checkback
                                          checkback
                                    Brake
                                    Brake monitoring
                                          monitoring
                            Motor
                            Motor protection
                                  protection
                            Motor
                            Motor ventilation
                                  ventilation
                            Setpoint
                            Setpoint prior
                                     prior to
                                           to brake
                                              brake
                            Brake-lifting
                            Brake-lifting delay
                                          delay
                            Relevelling
                            Relevelling up
                                        up coasting
                                           coasting
                            Relevelling
                            Relevelling down
                                        down casting
                                             casting
                            Levelling
                            Levelling
22
Fault diagnosis
                   Shaft
                    Shaft
                            Length
                            Length of
                                   of vane
                                      vane
                            LDG
                            LDG switching
                                switching points
                                          points
                            Terminal
                            Terminal landing
                                     landing
                            LDG
                            LDG description
                                description
                            LDG
                            LDG Offset
                                Offset
                            Decl./MinTrvl.
                            Decl./MinTrvl. Dst
                                           Dst
                                 UP/DOWN
                                 UP/DOWN
                                 DOWN
                                 DOWN (optional)
                                      (optional)
                            Insp.
                            Insp. trvl.
                                  trvl. limiter
                                        limiter
                            Acknowledgement
                            Acknowledgement window
                                            window
                            Encoder
                            Encoder connector
                                    connector
                            Encoder
                            Encoder rot.
                                    rot. dir.
                                         dir.
                            Encoder
                            Encoder resol.
                                    resol.
                            Encoding
                            Encoding
                            Pre-limit
                            Pre-limit switch
                                      switch
                            Deceleration
                            Deceleration contr.
                                         contr.
                            Adjustment
                            Adjustment travel
                                       travel
                                                     23
Fault diagnosis
                            Door
                             Door parameters
                                   parameters
                                  Kind
                                  Kind of
                                       of door
                                          door
                                  Approach
                                  Approach
                                  Door-time
                                  Door-time short
                                            short
                                  Door-time
                                  Door-time long
                                            long
                                  Reverse
                                  Reverse time
                                          time
                                  Loading
                                  Loading time
                                          time
                                  Nudging
                                  Nudging time
                                          time
                                  Motion
                                  Motion control
                                         control
                                  No.
                                  No. of
                                      of reversg.
                                         reversg. runs
                                                  runs
                                  Door
                                  Door activation
                                       activation
                                  Locking
                                  Locking magnet
                                          magnet
                                  Rot.
                                  Rot. shaft
                                       shaft door
                                             door lock
                                                  lock
                                  Emergency
                                  Emergency stop
                                            stop in
                                                 in the
                                                    the car
                                                        car
24
Fault diagnosis
      Configuration
       Configuration
             Kind
             Kind of
                  of control
                     control
             Car
             Car priority
                 priority
             Landing
             Landing priority
                     priority
             Fire
             Fire emergency
                  emergency
             Firemen
             Firemen
             Control
             Control light
                     light OFF
                           OFF
             Car
             Car light
                 light OFF
                       OFF
             Trvl.
             Trvl. cont.
                   cont. lock
                         lock -out
                              -out
            TrCntLckgTmClsdDoor
            TrCntLckgTmClsdDoor
            Comnd.
            Comnd. to
                   to call
                      call prior.
                           prior.
            Door
            Door lock
                 lock monitoring
                      monitoring
            Motion
            Motion control
                   control
                                      Car
                                      Car fan
                                          fan
            Delay
            Delay of
                  of starting
                     starting
                                      Comand-misuse
                                      Comand-misuse
            Homing
            Homing program
                   program
                                      Signals
                                      Signals C.O.P.
                                              C.O.P.
                     Week-program
                     Week-program
                                      Signals
                                      Signals call
                                              call units
                                                   units
                     Day-program
                     Day-program
                                      Evacuation
                                      Evacuation
                     Time
                     Time delay
                          delay
                                      Visualisation
                                      Visualisation
                     Oil
                     Oil warming-up
                         warming-up
                                      EN
                                      EN 81
                                         81
                                      Arrival
                                      Arrival gong
                                              gong
                                                           25
Fault diagnosis
                   Group
                    Group
                            Group
                            Group status
                                  status
                            Lift
                            Lift number
                                 number
                            Lift
                            Lift type
                                 type
                            Evaluation
                            Evaluation parameter
                                       parameter
                                  Decr./disp.
                                  Decr./disp. call
                                              call
                                  LDG
                                  LDG delay
                                      delay time
                                            time
                                  Time
                                  Time fl-to-fl
                                       fl-to-fl run
                                                run
                            External
                            External priority.
                                     priority.
                            Control
                            Control // light
                                       light off
                                             off
                            Door-open
                            Door-open time
                                      time
26
Fault diagnosis
      Service
       Service
            Fault
            Fault memory
                  memory
                       Displaying
                       Displaying memory
                                  memory
                       Canceling
                       Canceling memory
                                 memory
                                           Diagnoses
                                           Diagnoses
                       Utilization
                       Utilization
                                                 I/O
                                                 I/O CPU
                                                     CPU
            Sputnik-operation
            Sputnik-operation
                                                 I/O
                                                 I/O Mod1
                                                     Mod1 inputs
                                                          inputs
                       Activation
                       Activation
                                                 I/O
                                                 I/O Mod1
                                                     Mod1 outputs
                                                          outputs
                       LDG-input
                       LDG-input
                                                 I/O
                                                 I/O Mod2
                                                     Mod2 inputs
                                                          inputs
            Setting
            Setting of
                    of time
                       time
                                                 I/O
                                                 I/O Mod2
                                                     Mod2 outputs
                                                          outputs
            Setting
            Setting of
                    of date
                       date
                                                 I/O
                                                 I/O Mod3
                                                     Mod3 inputs
                                                          inputs
            Operation
            Operation counter
                      counter
                                                 I/O
                                                 I/O Mod3
                                                     Mod3 outputs
                                                          outputs
            Lightsensor
            Lightsensor
                                                 I/O
                                                 I/O Mod4
                                                     Mod4 inputs
                                                          inputs
                       Light
                       Light monitoring
                             monitoring
                                                 I/O
                                                 I/O Mod4
                                                     Mod4 outputs
                                                          outputs
                       Light
                       Light treshold
                             treshold
                                                 I/O
                                                 I/O AA Mod5
                                                        Mod5 inputs
                                                             inputs
            Language
            Language                             I/O
                                                 I/O Mod5
                                                     Mod5 outputs
                                                          outputs
            Service-Number
            Service-Number                       I/O
                                                 I/O Mod6
                                                     Mod6 inputs
                                                          inputs
            Elevator
            Elevator Number
                     Number                      I/O
                                                 I/O Mod6
                                                     Mod6 outputs
                                                          outputs
            Version
            Version                              I/O
                                                 I/O Mod7
                                                     Mod7 inputs
                                                          inputs
            Ser.
            Ser. interfaces
                 interfaces                      I/O
                                                 I/O Mod7
                                                     Mod7 outputs
                                                          outputs
            Debug
            Debug
                                                                      27
Fault diagnosis
                          Commissioning
                           Commissioning
                                Shaft
                                Shaft teach-in
                                      teach-in
                                Encoder
                                Encoder exchange
                                        exchange
                                LON-network
                                LON-network
                                      Number
                                      Number of
                                             of nodes
                                                nodes
                                      Cancelling
                                      Cancelling nodes
                                                 nodes
                                      Teaching
                                      Teaching
                                      Configuration
                                      Configuration
                                      Network
                                      Network read-in
                                              read-in
                                      Command
                                      Command sending
                                              sending
                                Inspection
                                Inspection speed
                                           speed
                                Parameter
                                Parameter default
                                          default
                                Password
                                Password protection
                                         protection
                                Password
                                Password modification
                                         modification
                                Period
                                Period of
                                       of validity
                                          validity
28
Commissioning
3 Commissioning
                                                                                                                29
Commissioning
3.4     LON-networt
                                         The LON-nodes are read automatically after RESET and the LON-
                                         networt is getting tied. In the display the following message
                                         appears:
          LON-nodes
           reading
Please wait
                                    
    Check number of nodes:
                                         This is only required for the first commissioning, after exchanging
                                         bus devices or in case of faults in the bus system.
No. of nodes =
CPU + No. of car         + No. of door   + No. of car       + No. of hall    + No. of hall    + No. of
      modules              modules         position           call panels      position         I/O-
      (C.O.P.)             (doors)         indicators                          indicators       modules
Assignment of LON-nodes:
                                         Set here TEACHING and confirm after 2-3 seconds with enter-key
                                          ↵ >. Now, the lift no. is assigned to the individual nodes. This step
                                         <↵
                                         has to be executed also with single lifts.
30
Commissioning
                                       
       Run the lift with the emergency operation to the buffer.
                                               Call successively in the main menu:
                                              Check the shaft teach-in. For that, call successively in the main
                                               menu:
                                               Zone side, door side and landing position must correspond to the
                                               actual shaft.
                                                                                                                   31
Commissioning
                                        Run the lift with emergency electr. control to about 0,5 m beyond a
                                        landing. Change into normal operation, lift will run with levelling
                                        speed downwards and will stop at the nearest landing.
                                        Example: Lift stops above the landing => Stopping B: new value
                                        35 - 000010mm = 25.
                                        For Stopping T: proceed in the same way i.e. run lift about 0,5m
                                        under any landing.....
                                        Now, the stopping values for the relevelling can be established.
                                        Proceed in same way as done for the stop switch. The value for
                                        initiation of relevelling (Relvl. ON) must be set.
                                        Check all lift-specific parameters and modify them if required.
                                        Now, you can change into normal operation.
32
Commissioning
                                                                                                                 33