Quickstart Hanpose AC-Servo
Quickstart Hanpose AC-Servo
Thank you for using the HANPOSE "ASD" AC servo system! This operating
manual provides information about the ASD series drivers and SS series
motors. Before use, please read the manual carefully to ensure proper use!
 Please disconnect the power supply for more than 5 minutes before removing or
 disassembling the driver, otherwise it may cause electric shock due to residual voltage.
 Please never touch the inside of the servo driver, otherwise it may cause electric shock
 Please insulate the connection part of the power supply terminal, otherwise it may cause
 electric shock.
 Please do not damage or pull on the cable, subject the cable to excessive force, put it
 under heavy objects or clamp it. Doing so may result in electric shock, which may cause
 the product to stop or burn out.
 Unless designated personnel, please do not set up, disassemble or repair, otherwise it may
 cause electric shock or injury.
 Please do not remove the cover, cables, connectors and optional accessories while the
 power is on, otherwise it may cause electric shock and damage the drive.
 Please follow the steps required by this manual for trial operation.
 If an operation error occurs while the servo motor is connected to the machine, it will not
 onlycause damage to the machine, but also sometimes cause personal accidents.
 Please do not change the maximum speed value, except for special purposes. Inadvertent
 change may damage the machine or cause injury.
 When the power is turned on and for a period of time after the power is cut off, the heat sink
 of the servo driver, the external braking resistor, and the servo motor may become hot.
 Please do not touch it, otherwise it may cause burns. To prevent accidental contact with
 hands or parts (cables, etc.), please take safety precautions such as installing an enclosure.
 Please do not touch the rotating part of the servo motor while it is running, as this may
 result in injury.
 If the servo motor is installed on the supporting machine and starts to run, make sure that
 the servo motor can be stopped at any time, otherwise you may get injured.
 Please install a stop device on the machine side to ensure safety.
 The brake of the servo motor with brake is not a stopping device to ensure safety. If a stop
 device is not provided, it may cause injury.
 If power is restored after a momentary power failure occurs during operation, the machine
 may restart suddenly, so please do not approach the machine.
 Please take measures to ensure that personal safety will not be endangered when
 restarting, otherwise it may cause injury.
 Please do not modify the product in any way, otherwise it may cause injury or
 mechanical damage.
 Please install the servo driver, servo motor, and external braking resistor on
 non-combustible materials, otherwise it may cause a fire.
 Between the power supply and the main circuit power supply of the servo driver
 (L1, L2 for single-phase, L1, L2, L3 for three-phase), please connect an electromagnetic
 contactor and a non-fuse circuit breaker. Otherwise, when the servo driver fails, the
 large current cannot be cut off, which may cause a fire.
                                              1
Model combination list
Panel operator
             Braking resistor
             (can be external)
                                     Motor interface
Grounding port
                                 2
 List of standard model combinations
Motor base              Model               Rated power         Matching driver      Encoder cable     Power cable
    40                 40SS05                  50W                 ASD210(E)        HBBM-SV-YC3000   HBDL-SV-YC3000
                                             Cable length
                                             3000: 3000mm length
                                             YC: 80mm and below
                                             none: 110 and 130mm
                                                            3
Motor model description
60 SS P 40-G 13 30
 Input power                      L1
                                                       Single-phase 220 VAC
 supply                           L2
                                  P               When using an internal braking
                                                     resistor, short P and D
 Braking                          D
 resistance                                   When using an external braking resistor, P and D are
                                  P           short-circuited and disconnected, and then the external
                                              braking resistor wiring is connected between P and C
                                  D           respectively. P and N are forbidden to connect.
                                  U
                                  V
 Motor wiring
                                  W           Connect the motor extension cable
PE
2 E 0V orange
3 CAN H green&white
   4                RS485-A                blue
   5                RS485-B             blue&white
6 CAN L green
   7                   GND             brown&white
                                                                                     Dual RS-485 interface
   8                  ——                  brown
                                                                 4
CN1-DB44 control signal interface definition
15
                                                                                                       1
                               30
                                                                                                            16
                                    44
                                                                                                       31
Functions        Signal             Pin number          Signal definition           Default function                    Description
                AS+、AT+                  24
 Analog                                                                                                          Analog input of speed/
command         AS+、AT+                  9                                                                         rotation, range: -
  input                                                                                                               10V~+10V.
                  AGND                   25
                                                                       5
 Display and panel operation
Functions       Symbol                 Description                                 Diagram
  Esc    key                             Escape key
  Increase                   Switch up selection or increase value
                             Switch down selection or decrease
  Decrease                   the value
  Confirm          SET                Confirm operation
The first layer is the main menu, there are 8 operation modes, press    、 keys to change the mode, press
the SET key to enter the second layer, perform specific operations, and press   to return to the main menu
from the second layer.
          Select parameter setting "P-" in the main menu, and press SET key
        to enter the parameter setting mode. First, use the          keys to
        select the parameter section, after selecting it, press the "SET" key
        to enter the parameter number selection of this section. Next, use
        the        keys to select the parameter number, after selecting it,
        press the "SET" key to display the parameter value.
                                                      6
Alarm and handling method
                            7
Alarm and handling method
                            8
Alarm and handling method
                            9
Alarm and handling method
                            10
Alarm and handling method
                            11
Alarm and handling method
                            12
Operation guide for position control mode
  Remarks:
  Position mode is a common working mode of servo drives, and its main use
  steps are as follows:
  1) Correctly connect the power supply of the servo main circuit and control
  circuit, as well as the motor power line and the encoder line. After power-on,
  the servo panel displays "r 0", which means that the servo power supply and
  encoder wiring are correct.
  2) Press the button to perform the servo JOG test run to confirm whether the
  motor can run normally.
  3) Refer to the wiring instructions in the diagram to connect the pulse
  direction input and pulse command input in the CN1 terminal and the
  required DI/DO signals, such as servo enable, alarm clear, positioning
  completion signal, etc.
  4) Set the position mode related settings. Set the DI/DO used according to
  the actual situation.
  5) Servo enable, control the rotation of the servo motor through the position
  command issued by the host computer. First, rotate the motor at low speed,
  and confirm whether the rotation direction and electronic gear ratio are
  normal, and then adjust the gain.
                                       13
Wiring diagram of holding brake
  Remarks:
  Brake wiring The connection of the brake input signal has no polarity, and the user needs
  to prepare a 24V power supply. The standard wiring example of the brake signal BK and the
  brake power supply is shown in the figure above
                                            15
         l   Internal position Pr mode position command description and related parameters
             Pr position command source is the use of parameters (P4-2, P4-3)-(P4-23, P4-24) 8 groups of
         built-in position command registers, which can be used with external I/O (CN1, POS0-POS 2 and
         CTRG) Choose one of eight groups to use as a position command :
                                                                                                 moving
location                                                correspond
                POS2     POS1      POS0      CTRG                            illustrate          speed
command                                                 parameter
                                                                                                 register
                                                           P4-2         Number of turns
                                                                                                 P4-4 _
    P1            0         0        0         ↑                        (+/-30000)
                                                                                                   (V1)
                                                          P4-3 _        Pulse (+/-max cnt)
                                                          P4-5 _        Number of turns
                                                                                                 P4-7 _
    P2            0         0        1         ↑                        (+/-30000)
                                                                                                   (V2)
                                                          P4-6 _        Pulse (+/-max cnt)
                                                          P4-8 _        Number of turns
                                                                                                 P4-10 _
    P3            0         1        0         ↑                        (+/-30000)
                                                                                                   (V3)
                                                          P4-9 _        Pulse (+/-max cnt)
                                                          P4-11 _       Number of turns
                                                                                                 P4-13 _
    P4            0         1        1         ↑                        (+/-30000)
                                                                                                   (V4)
                                                          P4-12 _       Pulse (+/-max cnt)
                                                          P4-14 _       Number of turns
                                                                                                 P4-16 _
    P5            1         0        0         ↑                        (+/-30000)
                                                                                                   (V5)
                                                          P4-15 _       Pulse (+/-max cnt)
                                                          P4-17 _       Number of turns
                                                                                                 P4-19 _
    P6            1         0        1         ↑                        (+/-30000)
                                                                                                   (V6)
                                                          P4-18 _       Pulse (+/-max cnt)
                                                          P4- 20        Number of turns
                                                                                                 P4- 22
    P7            1         1        0         ↑                        (+/-30000)
                                                                                                   (V7)
                                                          P4- 21        Pulse (+/-max cnt)
                                                          P4- 23        Number of turns
                                                                                                 P4- 25
    P8            1         1        1         ↑                        (+/-30000)
                                                                                                   (V8)
                                                          P4- 24        Pulse (+/-max cnt)
Status of POS0-2: 0 represents contact open circuit (open), 1 represents contact access (close). CTRG
↑ represents the moment when the connection changes from open circuit (0) to open circuit (1). max
represents the command pulse for one revolution of the motor.
The application of absolute position register is very wide, which is equivalent to a simple program control.
The user can easily complete the periodic operation by using the above table. For example, the position
command P1=10 revolutions, P2=20 revolutions, first issue the position command P1, and then issue the
position command P2. The difference between the two is as follows:
                                                     16
Speed Control Mode
                                              17
Parameters to be adjusted in speed control mode
l   Related parameters to be adjusted in the speed control mode
 Required parameters         Parameter Description           parameter value   Factory default
                                                   18
 Torque control mode
                                               19
Parameters to be adjusted in speed control mode
l      Torque control mode needs to adjust parameters
Required parameters             Parameter Description            parameter value   Factory default
command selection
offset compensation
PA50 Speed limit during torque control Set as needed Rated speed
                                                        20
 Description of origin return mode
                                               21
Description of origin return mode
Warranty 12 months
Provide a one-year warranty for its products from the date of
shipment, and our company will provide free maintenance
services for the products during the warranty period.
Email: info@hanpose.com
22