Manual Form Cure

Installation and Usage Instructions

Form Cure
Desktop Stereolithography
Post-Cure Chamber

Original English instructions and translations


Please read this manual carefully and keep it for future reference.
November 2019
REV 01
© Formlabs
1. Table of Contents

1. Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1 Read and Retain Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.2 Obtaining Documentation and Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1 Intended Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2 Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.3 Product Elements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.4 Form Cure Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3. Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1 Component and Subsystem Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2 Personal Protective Equipment (PPE). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.3 Specifications of Tools to be Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

4. Preparation and Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16


4.1 Arranging the Workspace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.2 Unboxing the Form Cure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.3 Installing the Form Cure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.4 Transporting Form Cure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

5. Using the Form Cure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18


5.1 Operational Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.2 Post-Curing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.3 Considerations for Specific Geometries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.4 Time and Temperature Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.5 Device Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.6 Emergency and Exceptional Situations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

6. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.1 Inspecting the Product. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.2 Inspection Tasks Between Post-Cure Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.3 Monthly Inspection and Maintenance Tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.4 Periodic Inspection and Maintenance Tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.5 Planned Maintenance Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7. Troubleshooting and Repair. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.1 Restarting with a Power Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.2 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.3 Disassembly and Repair. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

8. Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8.1 Guidance for Recycling and Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

9. Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

10. Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Read and understand this manual and its safety instructions before using the Form
Cure. Failure to do so can result in serious injury or death.
WARNING

DISCLAIMER
Formlabs has made every effort to ensure these instructions are as clear, complete, and correct
as possible. The information provided in this documentation contains general descriptions
and/or technical characteristics of the performance of the products contained herein. This
documentation is not intended as a substitute for, and is not to be used for, determining
suitability or reliability of these products for specific user applications. It is the duty of any
such user or integrator to perform the appropriate and complete risk analysis, evaluation, and
testing of the products with respect to the relevant specific application or use thereof. Neither
Formlabs nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of
the information that is contained herein. If you have any suggestions for improvements or
amendments or have found errors in this publication, please notify us.

Copyright © 2019 by Formlabs. All rights reserved.


support.formlabs.com

TRADEMARKS
All product names, logos, and brands are property of their respective owners. All company,
product, and service names used in this manual are for identification purposes only. Use of
these names, logos, or brands does not imply endorsement.

DOCUMENT REVISIONS
Date Version Document Changes
Oct 2015 REV 00 Initial publication of Quick Start Guide and Safety pamphlet
Nov 2019 REV 01 Initial publication

7
1. Preface
Congratulations on purchasing the Form Cure. On behalf of the employees who create and
support Formlabs technology, we thank you for your purchase.
The instructions in this manual provide information for skilled persons to understand safety, setup
and installation, operation, and maintenance of the Form Cure. These instructions are intended
for anyone who is installing, operating, maintaining, or otherwise interacting with the Form Cure.
Supervise young or inexperienced users to ensure an enjoyable and safe operation.

1.1 Read and Retain Instructions


Read and understand this manual and its safety instructions before using the Form Cure. Failure
to do so can result in serious injury or death. Keep all safety information and instructions for
future reference and provide them to subsequent users of the product.
Follow all the instructions. This will avoid fire, explosions, electric shocks, or other hazards that
may result in damage to property and/or severe or fatal injuries.
The Form Cure shall only be used by persons who have fully read and understood the contents
of this usage manual. Ensure that each person who uses the Form Cure has read these
warnings and instructions and follows them. Formlabs is not liable for cases of material damage
or personal injury caused by incorrect handling or non-compliance with the safety instructions.
In such cases, the warranty will be voided.

1.2 Obtaining Documentation and Information


Visit support.formlabs.com to:
• Access the latest version of all Formlabs product documentation.
• Contact Formlabs to request documentation, usage instructions, and technical information.
• Submit any comments or feedback regarding what is good and what can be improved.
• Request additional training.
1.2.1 Support and service
Retain a record of the original purchase to request warranty services. Service options depend
on the status of the specific product’s warranty. Include the serial name of the product when
contacting Formlabs for product support.
Instead of a serial number, all Formlabs machines have a serial name, which is a unique identifier
to track the history of manufacturing, sales, and repair, and to distinguish usage when connected
to a network. The serial name is on the back panel of the machine in this format: “AdjectiveAnimal.”
Service providers of Formlabs products also provide support and service. To the extent that
Formlabs or a certified service provider offers other or extended warranties, the terms of the
separate offer may apply. For products purchased from certified service providers, contact
the original service provider for assistance before contacting Formlabs.
For any support or service requests, including product information, technical assistance, or
assistance with instructions, contact Formlabs Services or a certified service provider:

support.formlabs.com USA Germany


Formlabs, Inc. Formlabs GmbH
35 Medford St. Nalepastrasse 18-50
Somerville, MA, USA, 02143 12459 Berlin, Germany

8
1.2.2 Returns
Formlabs accepts returns for unopened, unused, undamaged products within 30 days of the
shipment date. Returns must be authorized by Formlabs. Visit Formlabs.com for more detailed
information about returning your purchase.
1.2.3 Warranty
This product is protected under warranty. Formlabs offers a warranty for all Formlabs-branded
hardware. Unless otherwise expressly stated, the Terms of Service, including the Warranty,
constitute the entire agreement between you and Formlabs with respect to the Service and
any product you purchase from Formlabs and supersedes all prior or contemporaneous
communications, proposals and agreements, whether electronic, oral or written, between you
and Formlabs. Read the warranty for more details on the Formlabs warranty for your region:
US formlabs.com/support/terms-of-service/#Warranty
EU (EN) formlabs.com/support/terms-of-service/eu/
EU (DE) formlabs.com/de/support/terms-of-service/eu/
EU (FR) formlabs.com/fr/support/terms-of-service/eu/

Preface | 9
2. Introduction
2.1 Intended Use
The Form Cure provides the light and heat necessary to post-cure 3D printed parts to their
optimal properties. The final performance characteristics of cured photopolymer resin may vary
according to your compliance with the instructions for use, application, operating conditions,
material combined with, end use, or other factors.

In some cases, the additive manufacturing process may inherently result in variable
NOTICE
performance characteristics between manufacturing runs or within a specific part.
Such variances may not be apparent and may result in unexpected defects in
additively fabricated parts.

You must independently verify the suitability of additive manufacturing,


WARNING
stereolithography, Form Cure, and any specific designs or materials employed for the
application and intended purpose before use. In no event shall Formlabs be liable for
any loss, death, or bodily injury that you suffer, or that you cause to any third party, in
connection with your use of Formlabs products. To the fullest extent legally permitted
Formlabs EXPRESSLY DISCLAIMS ANY IMPLIED OR EXPLICIT WARRANTY OF
FITNESS for a particular usage, the particular nature and circumstances of said usage
being unforeseen and unforeseeable to Formlabs.

Formlabs is not a manufacturer of medical devices. Formlabs provides tools and


WARNING
materials that may be used in many applications, but makes no claims as to the safety
or effectiveness of any specific devices made using Formlabs products. Certain
Formlabs products, such as those commonly known in the industry as “biocompatible”
resins, have been engineered to comply with relevant industry standards. The specific
standards and most relevant technical specifications may be identified within the
technical data sheets and have been tested according to relevant testing protocols
for those standards and specifications. Biocompatible resins are a speciality product,
developed for use by medical professionals, and should be used in accordance with
their instructions for use.

Do not modify. The Form Cure is intended for use as-is. Modifying the unit without
WARNING
explicit approval and directions from Formlabs will invalidate your warranty, and could
potentially ruin the machine and cause you bodily harm.
Never remove the bottom panel of the unit.

10
2.2 Technical Specifications
Shipping Weight 7.3 kg
(16.1 lb)
Product Weight 5.6 kg
(12.4 lb)
Shipping Dimensions 35.4 × 35.4 × 45.6 cm
(14 × 14 × 18 in)
Product Dimensions 26.2 × 26.2 × 34.0 cm
(10.3 × 10.3 × 13.4 in)
Minimum Space Requirement 26.2 × 26.2 × 64.0 cm
(10.3 × 10.3 × 25.4 in)
Power Requirements 100–240 V ~
6.0 A 50/60 Hz
144 W
Electrical Safety Standard 60950-1:2005+A1:2009+A2:2013
(and applicable national deviations)
Sound Emission Does not exceed 70 dB(A).

Turntable Diameter 19.3 cm (7.6 in)

Maximum Part Height 18.5 cm (7.28 in)

Operating Temperature Suggested 18—28 °C


(64—82 °F)
Maximum Cure Chamber 80 °C
Temperature (176 °F)
Light Source 13 multi-directional LEDs

LED Power 39 W

LED Radiant Power 9.1 W

LED Wavelength 405 nm

Introduction | 11
2.3 Product Elements
1 Cover Double walls insulate the cure
chamber and internal surfaces reflect light.
2 Heater 100 W heating module can heat the

chamber up to 80 °C / 176 °F.


1
3 LEDs An array of thirteen (13) 405 nm LEDs

help to post-cure parts. Secondary lights


illuminate the turntable when the cover is
open and during heating. 2
4 Turntable Rotating plate ensures balanced
3
post-curing across all exposed surfaces.
5 Display Shows status, time, temperature,
4
and options for configuring the Form Cure.
6 Knob Turn or press to adjust time and
5 7
temperature settings and to start, pause, or 6
stop post-curing.
7 Power Supply Provides power to the Form

Cure. Specifications: 24 V, 6 A.
See 10 Glossary for full product terminology.

2.4 Form Cure Controls


When connected to power, use the knob to program and operate the Form Cure:
• Rotate the knob counterclockwise or clockwise to move between items in the menu.
• Press the knob to select an option on the display.
The following options are available from the main menu on the Form Cure display:
• Start: Initiate post-curing by activating the heater and internal LED lights. The 405 nm lights
begin post-curing once the heater reaches the target temperature.
• Time: Press the knob to select and adjust the time, indicated in minutes.
• Temperature: Press the knob to select and adjust the temperature indicated in degrees Celsius.
Check each material’s recommended post-curing temperature before beginning a cycle.
While preheating, the display shows the preheating status, including the current and the target
temperature. After beginning a post-cure cycle, the display shows the remaining time and
additional menu options. Select Pause to turn off the heater and LEDs, while preserving the
remaining time in the cure cycle. Opening the cover automatically pauses the cure cycle. Select
End to cancel the remaining time in the cure cycle while also stopping the heater and LEDs.

12
3. Safety Warnings

Read and understand this manual and its safety instructions before using the Form
WARNING
Cure. Failure to do so can result in serious injury or death.

Supervise young or inexperienced users to ensure safe operation.


The instructions contain warnings and safety information, as explained below:

Danger indicates a hazard with a high level of risk which, if not avoided, will result in death
DANGER
or serious injury.

Warning indicates a hazard with a medium level of risk which, if not avoided, could result in
WARNING
death or serious injury.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor
CAUTION
or moderate injury.

Notice indicates information considered important, but not hazard-related.


NOTICE

HOT SURFACES: Do not touch hot surfaces.

3.1 Component and Subsystem Safety


3.1.1 Electronic Components
The Form Cure is a professional appliance that includes electronic components. As with any
such appliance:

• Do not operate the Form Cure with a damaged cord or plug.


WARNING
• Always disconnect power before cleaning.
• Only use well-maintained equipment.
• Operate on a clear and level surface.

3.1.2 Hot Surfaces


The Form Cure contains a 100 W heater to help ensure parts are strong after post-curing.
While the heater and fan designs limit overheating and the heater is insulated to contain heat,
surfaces of the Form Cure and printed parts may be hot during and after use.

Do not touch hot surfaces.


CAUTION

Take care when removing parts from the Form Cure. The metal turntable can remain hot during
and after a cure cycle. Always allow the turntable to cool completely before touching or cleaning.

Safety Warnings | 13
Like any heating appliance, a fire may occur if the Form Cure maintains extended contact with
flammable materials, such as walls or curtains. Keep the Form Cure away from walls and curtains.
Keep the area surrounding the turntable clean, and only post-cure parts that have been
completely dried. Accumulation of cured material creates the possibility of malfunction.
3.1.3 Light and Heat
The Form Cure uses heat and 405 nm light to post-cure 3D printed parts. The cover includes
an interlock system that is designed to automatically pause heating and extinguish the cure
lights when the cover is open.

For best results, avoid opening the cover while the Form Cure is operating.
NOTICE

3.1.4 Resin
Respect Formlabs resin like any household chemical. Follow standard chemical safety
procedures and Formlabs resin handling instructions.
In general, Formlabs resin is not approved for use with food, drink, or medical applications on
the human body. However, biocompatible resins, such as Dental SG, are biologically safe for
specific types and lengths of exposure to the human body. Refer to information about each
specific resin for more detail.

Wear gloves whenever handling liquid resin or isopropyl alcohol.


WARNING

Never ingest resin in liquid or solid form. If swallowed, immediately call a poison
WARNING
center or medical professional.

Always consult the SDS (Safety Data Sheet) as the primary source of information to
NOTICE
understand safety and handling of Formlabs materials. Combinations of resin and
solvents should be handled according to the restrictions of both. For questions,
consult the appropriate SDS(s).

3.1.5 Radio Interference


This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to CFR Title 47, Part 15 of FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at their own expense.
Changes or modifications to this product not authorized by Formlabs could void the
electromagnetic compatibility (EMC) and negate your authority to operate the product.

Use of controls or adjustments or performance of procedures other than those


CAUTION specified herein may result in hazardous radiation exposure.

14
3.2 Personal Protective Equipment (PPE)

Resin may cause skin irritation or an allergic skin reaction. Wear gloves when handling
WARNING
liquid resin or resin-coated surfaces. Wash skin with plenty of soap and water.

Some methods of support removal may cause small pieces of supports to break away.
CAUTION
Beware of flying debris. Wear eye protection and gloves to protect the skin and eyes.

3.3 Specifications of Tools to be Used


The Form Cure shall only be used with supplied accessories and additional tools recommended
by Formlabs. Third-party accessories and materials may cause damage.
Purchase additional supplies:
• Powder-free, chemical-resistant, disposable gloves (nitrile or neoprene)
• Sandpaper
• Mineral oil
• Primer and paints

Safety Warnings | 15
4. Preparation and Setup

Consider the weight and dimension of the product for installation.


NOTICE

4.1 Arranging the Workspace


For best results:
1. Choose a stable, level workspace to install and operate the Form Cure.
2. Reserve the following minimum dimensions for the most convenient access:
° Width: 36 cm (14 in)
° Depth: 36 cm (14 in)
° Height: 64 cm (25.2 in)
° The cover opens upward from the front to allow inserting and removing printed parts
from the turntable. To fully open, the Form Cure requires an additional clearance of 30
cm (12 in) above the unit for a total clearance height of 64 cm (25.2 in). The Form Cure
unit weighs 5.6 kg (12.4 lb).
3. Allow additional space for accessories, such as the Formlabs SLA printer, Finish Kit, and
Form Wash.
4. Ensure either the wall outlet or power supply for the Form Cure is easily accessible. To
disconnect the equipment from mains electricity and power off the unit, unplug the power
cable from the wall outlet, or the power supply.

4.2 Unboxing the Form Cure


The Form Cure ships in a cardboard carton, protected by foam inserts above and below the
machine. The upper foam insert also contains the accessories. During unboxing, inspect the
Form Cure for any damage or missing items. In the case of damage or missing items, contact
Formlabs or the certified service provider.
To unbox the Form Cure:
1. Open the box from the top.
2. Lift and remove the foam insert containing the power supply.
3. Lift the Form Cure out of the box.
4. Remove the turntable, located at the bottom of the box.

Remove all packaging material before connecting power. Retain all packaging and
NOTICE
inserts for warranty service.

4.3 Installing the Form Cure


To install the Form Cure:
1. Find a clean, level surface with a nearby power source.
2. Remove the thin plastic wrapper from the Form Cure exterior.
3. Lift the cover.
4 Insert the turntable on the circular wheel mount at the base of the cure chamber.
5 Connect the power cable and external supply to the Form Cure and a power source.

16
4 5

The Form Cure is ready to use once the turntable is installed and the power is connected. Each
cycle requires time to preheat before the 405 nm lights begin post-curing. The preheating time
depends on the current temperature and the target post-cure temperature.

4.4 Transporting Form Cure


Refer to 2.2 Technical Specifications for product weight and dimensions. Keep the packaging
for transportation or shipping.
The Form Cure complete packaging kit consists of:
• 1 outer cardboard carton
• 1 foam bottom insert
• 1 foam upper insert, which holds the small accessory boxes
• Plastic wrap

Original packaging is required for warranty service. Do not ship with uncured resin
NOTICE
inside the device. Resin left inside can damage the product in transit, which may lead
to additional fees or void the warranty.

To prepare to transport the Form Cure:


1. Remove the turntable.
2. Wipe residual resin from all surfaces.
3. Close the cover.
4. Wrap the Form Cure with plastic wrap to secure the cover.
5. Reassemble the box.
6. Place the bottom foam insert in the box.
7. Place the Form Cure on top of the bottom foam insert.
8. Place the upper foam insert on top of the Form Cure.
9. Seal the box with tape.

When shipping a machine to Formlabs for service, do not ship the accessory tools
NOTICE
or the power supply. Accessories will not be returned after service. The product’s
original packaging is required for warranty service. Contact other authorized resellers
for unique guidance on shipping requirements.

Preparation and Setup | 17


5. Using the Form Cure
5.1 Operational Environment
Operate the Form Cure in a well-ventilated room with a temperature of 18–28 °C (64–82 °F).
For optimal performance, do not exceed this range.

5.2 Post-Curing
5.2.1 Insert Washed and Dried Prints
Fully dry all solvent off of printed parts after
washing. Check all surfaces, because curing
non-dried parts may trap solvent inside the
part, prevent parts from strengthening, and
affect quality. Once parts are dry, lift the cover,
then distribute parts on the round turntable.
Place parts with the most even spacing
possible to allow light and heat to reach all
areas. Gently close the cover.

The Form Cure contains a heater to


WARNING
enable post-curing. Take care when
inserting and removing parts from the
Form Cure, because the metal turntable
may be hot.

5.2.2 Set Post-Cure Time and Temperature


Turn the knob to navigate the display menu. Press the knob to select a feature or setting.
Select the time and temperature, and then select Start. The LEDs will activate and the timer
will start once the heater has reached the target temperature. Once a cure cycle has started,
use the display or open the cover to pause post-curing.
See support.formlabs.com or 5.4 Time and Temperature Settings for specific post-cure
settings for each resin type.

The printed part must be in the Form Cure while it heats. If the part is not placed in
NOTICE
the Form Cure until preheating is complete, it may cause cracking.

18
5.2.3 Collect Prints
When the cure cycle completes, the LEDs and heater will turn off. Lift the cover and remove
parts. Use caution; the metal turntable may be hot.
5.2.4 Part Finishing
Once parts are post-cured, use the flush cutters that come in your Finish Kit or Form
Wash to carefully cut the supports attached to the part(s). Supports can also be removed
before post-curing, but parts may warp under exposure to light and heat without
structural support.

Wear safety glasses to protect eyes from dislodged fragments of supports.


CAUTION

In addition to removing supports, use sanding, polishing, priming, or painting to improve


presentation, or use other equipment to create molds from printed parts.

5.3 Considerations for Specific Geometries


Consider the specific geometry of each part when starting the post-cure cycle. Modify the post-cure
process for parts that are large or long, have dense support structures, or have thick or thin features.
5.3.1 Remove Dense Supports
Some parts require more dense or thicker support structures. These can inadvertently block
light from reaching some part surfaces during post-curing. The Form Cure helps ensure even
post-curing by rotating the part during the cure cycle and exposing the part to light from all
directions, including underneath the turntable. Remove some supports, only as needed, to
ensure that light can easily reach all part surfaces. Leave some supports in place whenever
possible to prevent features from warping during post-curing.
5.3.2 Plan for Large or Long Parts
The Form Cure turntable has a diameter of 19.3 cm (7.6 in), and the maximum part height that
can be post-cured in the Form Cure is 18.5 cm (7.3 in). Most parts should be post-cured before
removing support structures to preserve their shape and prevent warping. While some parts
may fit on the turntable more easily without supports, long or tall prints may require special
arrangements to stand on the turntable without support. Consider the part dimensions when
designing the support structures or planning the post-cure steps.
5.3.3 Add Time for Thick Parts
Large or thick parts may require a longer post-curing time or higher temperatures because the
part takes longer to heat. Light alone cannot post-cure beyond the surface of the part, which
is one advantage of the Form Cure heating functionality. When post-curing thick geometries,
warm the part before post-curing and allow extra time for the Form Cure to preheat to the
target temperature before starting the post-cure lights and timer.
5.3.4 Add Supports for Thin Features
Warping during post-curing may occur if a part is especially thin, inadequately supported, or unevenly
exposed to light. The Form Cure helps prevent warping by rotating the part during the cure cycle and
by exposing the part to light from all directions, including underneath the turntable. Use support settings
or manual editing to design sufficient supports so that thin features do not warp during post-curing.
In the case of a thin, flat, sheet-like object, placing the part directly on the turntable may offer
the best support during post-curing.

Using the Form Cure | 19


5.4 Time and Temperature Settings
For the best results, use the recommended time and temperature settings tested specifically
for use with the Form Cure.
Each material’s print settings are designed and refined to print parts successfully at optimal
speeds. Additional post-curing further improves the functional properties of the materials.
Post-curing exposes parts to light and heat and strengthens crosslinks in the polymer structure,
improving the parts’ strength, stiffness, and temperature resistance. Due to the increased number
of bonds the material becomes more tightly packed and will shrink slightly. Each material’s print
settings are designed to account for the expected shrinkage during printing and post-curing.
Although using a higher temperature for post-curing results in a faster post-cure, a higher
temperature setting may also cause some materials to warp, depending on the part geometry
and features. When choosing to modify the recommended post-cure settings, the material must
be able to withstand the temperature and maintain a stable material structure.
Formlabs resins are designed for printing and post-curing with 405 nm light.

resin type cure time (min) temperature (°C)


standard resins
Clear Resin Recommended 1 15 60
Full Cure 30 60
Black Resin Recommended 1 30 60
White Resin
Grey Resin
Full Cure 60 60
Color Resin Recommended 1 30 60
Full Cure 60 60
Draft Resin Better elongation 5 No heat
Better UTS 5 60
engineering resins
Tough Resin Recommended 1 60 60
Full Cure 120 60
Durable Resin Full Cure 2 60 60
Flexible Resin Recommended 1 15 60
Full Cure 60 60
High Temp Resin v1 Recommended 1 30 60
Full Cure 60 60
High Temp Resin v2 Recommended 3 120 80
Rigid Resin Full Cure 4 15 80
Grey Pro Resin Full Cure 4
15 80
Elastic Resin Full Cure 20 60
Ceramic Resin N/A 5
N/A N/A

20
resin type cure time (min) temperature (°C)
dental resins
Dental SG Resin Full Cure 6 30 60
Dental LT Clear Resin Full Cure 6 20 80
Model Resin Recommended 1 30 60
Full Cure 60 60
Denture Resins Full Cure 7 30 + 30 80
Surgical Guide Resin Full Cure 6 30 60
Castable Wax Resin N/A 5
N/A N/A
jewelry resins
Castable Resin Full Cure 8 240 60
Castable Wax Resin N/A 5 N/A N/A

1 The recommended post-cure settings achieve close-to-maximum mechanical performance and minimize the post-cure
time. The full post-cure settings achieve the maximum mechanical properties and require significantly more time. Use
full post-cure settings when using materials for functional applications.

2 For parts printed with Durable Resin, the tensile modulus continues to increase steadily throughout the first hour of post-
curing. There is only one proposed post-curing setting.
3 There are several post-curing options for High Temp v2. To achieve the highest HDT, also post-cure the parts in a non-
food oven. Refer also to the technical data sheet to understand how different options affect mechanical properties, and
choose the post-cure option that is best suited to the intended application.

4 There is no significant gain in properties after 15 minutes. There is only one recommended post-curing time.
5 Does not require post-curing. After washing, allow parts to fully dry before firing/casting.
6 This cure setting ensures that parts achieve both biocompatibility and optimum mechanical properties.
7 Fill a glass container with glycerin. Preheat the glycerin to 80 °C in the Form Cure. Use heat resistant silicone tongs to
fully submerge the assembled denture in the glycerin, leaving the container inside the Form Cure. Cure for 30 minutes.
After the first 30 minute post-cure, flip the denture to the opposite side. Post-cure again for 30 minutes.

The glycerin and denture at 80 °C are hot. Use heat resistant silicone tongs to insert and remove the denture from
the curing chamber.
WARNING

8 Cure for 4 hours to increase the part strength. After curing, follow the Castable Resin: Jewelry Pattern Burnout Process
found on support.formlabs.com. Increasing the cure time may improve casting results, particularly for thicker parts, though
casting success depends more on the part geometry and casting process. Testing results show no disadvantages for
increasing cure time.

These settings will be updated periodically. Always refer to formlabs.com/cure-support for the
most updated information about post-curing printed parts with the Form Cure.

5.5 Device Management


5.5.1 Powering Off the Form Cure
Turn off the Form Cure completely when moving or storing the device and to conserve power.
To turn off the Form Cure completely, disconnect the power cord from the power source.
Ensure either the wall outlet or power supply is easily accessible.
The Form Cure display will automatically power off after a period of inactivity.

Using the Form Cure | 21


5.5.2 Updating the Firmware
The Form Cure includes a USB port for the possibility of future firmware updates. See 6.5.1
Updating the Form Cure Firmware.
5.5.3 Accessing the Serial Name
The serial name is on the back panel of the machine in the format “AdjectiveAnimal.” The
serial name is also available on the display. To access the serial name or firmware version
on the display:
1. Disconnect the power cable.
2. Reconnect the power cable.
3. When the display shows Formlabs, press and hold the knob immediately. The display
shows the serial name (preceded by Cure-) and firmware version.

5.6 Emergency and Exceptional Situations


Formlabs has made every effort to provide updated safety data sheets (SDS) for every resin
product, in accordance with the latest government guidelines. Always consult the SDS as
the primary source of information to understand safety and handling of Formlabs materials.

In an emergency involving resin, always refer to the safety data sheet and/or seek
WARNING
help from a medical professional.

When handling solvents, always consult the safety data sheet (SDS) from the solvent supplier
as the primary source of information. Handle solvents with gloves in a well-ventilated area.
Keep flammable solvents away from heat, sparks, and open flame. Some solvents, such as
isopropyl alcohol (IPA) evaporate rapidly, so keep bottles closed whenever possible.
Promptly clean and inspect the Form Cure if any liquid resin spills on or in it to minimize any
cosmetic or functional damage to the device. If you have experienced an accidental resin spill,
document the problem with photos and clean the unit as best as possible. Contact Formlabs
or a certified service provider as soon as possible.

22
6. Maintenance

• Formlabs provides instructions to advise skilled and non-skilled persons in


WARNING
installing, operating, and maintaining the Form Cure. The Form Cure shall only be
maintained by a qualified and trained person.
• Do not open the Form Cure and/or investigate internal components unless under
the guidance of Formlabs or an authorized reseller. Contact Formlabs or an
authorized reseller for any additional guidance.
• Unauthorized disassembly or repair procedures may damage the Form Cure and
void the warranty.
• Wear personal protective equipment when performing maintenance tasks. Use
tools only as described.
• Disconnect the power cable before maintenance.

Isopropyl alcohol (IPA) is suitable to clean most surfaces, including cured and uncured resin.
When wiping the cover surfaces, use a non-abrasive cloth. Other materials may scratch the cover.

6.1 Inspecting the Product


6.1.1 Before Each Post-Cure Cycle

inspect refer to section


Installation Environment Operational Environment 5.1
Turntable Turntable Maintenance 6.2.1
Parts to be post-cured Dry Parts and Keep Equipment Clean 6.2.2

6.1.2 Monthly
inspect refer to section
Interior surfaces Interior Surface Maintenance 6.3.1
Light diffusers Light Diffuser Maintenance 6.3.2

6.1.3 Every 3 Months


inspect refer to section
Cover Inspect the Cover 6.4.1
Display Inspect the Display 6.4.2

6.2 Inspection Tasks Between Post-Cure Cycles


6.2.1 Turntable Maintenance
The Form Cure relies on the turntable’s rotation to expose part surfaces to even amounts of
light and heat. The turntable must have sufficient clearance to continue rotating.
Periodically lift the turntable to inspect underneath it for small pieces of cured resin. Remove particles of
cured resin from above and below the turntable to ensure the turntable can rotate without interruption.
Clean the turntable and the surface underneath as needed. Use IPA to clean the turntable
or the base if necessary, and allow IPA to fully evaporate before starting a post-cure cycle.

Maintenance | 23
6.2.2 Dry Parts and Keep Equipment Clean
Completely wash and dry all parts before post-curing in the Form Cure. Do not operate the
Form Cure with uncured resin, partially cured resin, or other liquids on the turntable.

6.3 Monthly Inspection and Maintenance Tasks


6.3.1 Interior Surface Maintenance
The internal surfaces of the Form Cure are covered in a reflective coating that reflects the
light from the 405 nm LEDs and ensures that parts post-cure evenly. If the reflective coating
is damaged or covered, parts may not post-cure properly.
Visually inspect the internal surfaces of the Form Cure for traces of resin, cracks, or
other damage. Resin will harden during the cure cycle. Cured resin blocks light and
must be removed.
If parts are washed but not fully dry before post-curing, certain washing solvents, such as
tripropylene monomethyl ether (TPM), may evaporate and form deposits on the interior surfaces
of the Form Cure. These deposits will cloud the reflective coating and prevent parts from post-
curing properly. Clean the reflective coating as needed. Use IPA to clean the reflective coating
and allow IPA to fully evaporate before starting a post-cure cycle.
6.3.2 Light Diffuser Maintenance
The 405 nm and white secondary LEDs in the Form Cure are covered by frosted light diffusing
panels. These light diffusers spread the light from the LEDs and ensure that parts post-cure
evenly. If the light diffusers are damaged or covered, parts may not post-cure properly.
Visually inspect the light diffusers for traces of resin, cracks, or other damage. Resin will
harden during the cure cycle. Cured resin blocks light and must be removed. If parts are
washed but not fully dry before post-curing, certain part washing solvents, such as tripropylene
monomethyl ether (TPM), may evaporate and form deposits on the interior surfaces of the Form
Cure. These deposits will coat the light diffusers and prevent parts from post-curing properly.
Clean the light diffusers as needed. Use IPA to clean the light diffusers and allow IPA to fully
evaporate before starting a post-cure cycle.

6.4 Periodic Inspection and Maintenance Tasks


6.4.1 Inspect the Cover
Visually inspect the cover for traces of resin, cracks, or other damage. Clean the cover with a non-
abrasive microfiber cloth and soapy water or a general purpose cleaner, such as glass cleaner.
6.4.2 Inspect the Display
Visually inspect the display for any traces of resin. Check that the knob turns easily and that
the display responds to inputs. Clean the display with a non-abrasive microfiber cloth and
general purpose cleaner, such as glass cleaner.

6.5 Planned Maintenance Procedures


For detailed guidance and visual assistance, search on support.formlabs.com.
Maintenance tasks shall be done according to the following plan:

task frequency section


Update the firmware When indicated by Formlabs. 6.5.1

24
6.5.1 Updating the Form Cure Firmware
Formlabs regularly releases updated firmware to fix bugs and improve functionality. Review
the PreForm and firmware release notes to learn more about the improvements that come
with each version’s release.
To update the firmware:
1. Connect the Form Cure with a USB cable to a computer running the latest version of PreForm.
2. Locate and run the Form Wash/Cure Updater tool in the PreForm installation folder to check
for firmware updates and to update the firmware.
3. When the updater tool detects the unit, select Update Firmware.
4. The tool uploads the new firmware and restarts the unit to complete the update. The update
should take approximately 20 seconds. The turntable may rotate during firmware updates.

Do not disconnect the USB or power cables during the update.


NOTICE

5. Firmware Up To Date appears next to the connected unit in the main updater window.
Select Done once the update is complete.
6. Repeat steps 1–5 to update firmware on additional Form Cure units.
7. Select Quit to close the updater.

Maintenance | 25
7. Troubleshooting and Repair
For detailed guidance and visual assistance, search on support.formlabs.com.

7.1 Restarting with a Power Cycle


If the display freezes during or after the firmware update, power cycle the Form Cure unit:
1. Unplug the unit.
2. Wait at least 10 seconds to ensure a complete power cycle.
3. Reconnect the power cable to restart the unit.

7.2 Troubleshooting
In the case of an error or abnormal activity with the Form Cure, reference the following errors,
causes, and proposed solutions. Complete the initial troubleshooting steps and carefully
document all results. Contact Formlabs or an authorized reseller for additional assistance.
error cause solution
The display does Power failure or a faulty Check that the power supply indicator light is
not turn on. electrical connection illuminated. Try another outlet.
Disconnect and reconnect the power.
The display does Firmware bug Disconnect and reconnect the power.
not turn off or sleep. Update the firmware. See 6.5.1 Updating the
Form Cure Firmware.
The display Interlock magnets are Wiggle the cover from side to side.
indicates that the missing or misaligned Check that the interlock magnets are installed in
cover is open when the bottom edge of the cover.
the cover is closed.
The 405 nm LEDs Power failure or a faulty Check that the power supply indicator light is
and secondary white electrical connection illuminated. Try another outlet.
LEDs do not turn on. Disconnect and reconnect the power.
The 405 nm LEDs The Form Cure has Wait for the Form Cure to reach its target temperature.
do not turn on. not reached its target See 5.2.2 Set Post-Cure Time and Temperature.
temperature Check that the power supply indicator light is
Power failure or a faulty illuminated. Try another outlet.
electrical connection Disconnect and reconnect the power.
The heater does Abnormal display behavior Disconnect and reconnect the power.
not reach the Environmental conditions Ensure that the operating environment is in
target temperature. Poor airflow around power the recommended temperature range. See 5.1
supply Operational Environment.
Ensure that there is adequate airflow around the
Form Cure power supply and that it is not placed in
an enclosed space.
The turntable does Turntable is obstructed Ensure that no cured resin or printed parts are
not turn. Turntable is not fully blocking the turntable. Reorient large prints as
seated necessary. See 5.3.2 Plan for Large or Long Parts.
Faulty or damaged motor Reseat the turntable on on the circular wheel
assembly mount. See 4.3 Installing the Form Cure.
Replace the Form Cure motor assembly. See 7.3
Disassembly and Repair.

26
error cause solution
Parts are Expired resin Check the expected lifetime of the resin used for
undercured or do Part was washed but not the print.
not have desired fully dried before post- Fully dry all solvent off of parts before post-curing.
mechanical curing
properties.
Post-cured parts Part was not washed Wash liquid resin off of printed parts before post-
have tacky or before post-curing curing.
sticky surfaces. Part was washed but not Fully dry all solvent off of parts before post-curing.
fully dried before post-curing

7.3 Disassembly and Repair

All steps that involve opening the Form Cure and/or investigating internal
NOTICE
components should be done by skilled persons under the guidance of Formlabs or a
certified service provider.

Contact Formlabs or a certified service provider to receive repair instructions and authorization.
The following tools, equipment, and materials are needed for reparation tasks:
task required supplies cause
Replacing the 2.5 mm hex wrench, The Form Cure display or knob has
display assembly replacement part(s) stopped functioning.
Replacing the motor 2.0 mm hex wrench, The turntable has stopped functioning or
assembly 2.5 mm hex wrench, behaves erratically.
replacement part(s)
Reseating the 2.5 mm hex wrench The Form Cure display or knob has
ribbon cable stopped functioning.

Troubleshooting and Repair | 27


8. Disposal
8.1 Guidance for Recycling and Disposal
8.1.1 Disposal of electronic components
The symbol on the product, accessories, or packaging indicates that this device must not be
treated as nor disposed of with household waste. When you decide to dispose of this product,
do so in accordance with local environmental laws and guidelines. Dispose of the device via
a collection point for the recycling of waste electrical and electronic equipment. By disposing
of the device in the proper manner, you help to avoid possible hazards for the environment
and public health that could otherwise be caused by improper treatment of waste equipment.
The recycling of materials contributes to the conservation of natural resources. Therefore do
not dispose of your old electrical and electronic equipment with the unsorted municipal waste.
8.1.2 Disposal of packaging waste
Keep the packaging for transporting your Form Cure. Form Cure packaging materials are
designed to be kept and reused for transportation or shipping.
The packaging is made of cardboard and plastic-based materials. Dispose of packaging
through your local waste and recycling facilities. By disposing of the packaging waste in the
proper manner, you help to avoid possible hazards for the environment and public health.

28
9. Index
C S
clean 14, 16, 22, 23, 24 safety 7, 8, 10, 13, 14, 19, 22, 30
cleaning 13 Safety Data Sheet 14
comply 10, 14 SDS 14, 22
compliance 8, 10 shipping 17, 28
cover 12, 14, 16, 17, 18, 19, 23, 24, 26, 30 solvent 18, 22, 27
D specifications 10
display 12, 18, 21, 22, 24, 26, 27, 30 T
F technical data 10, 21
firmware 22, 24, 25, 26 temperature 12, 17, 18, 19, 20, 26, 30
TPM 24
H
transport 17
heat 10, 12, 13, 14, 18, 19, 20, 21, 22, 23, 30
transporting 28
I turntable 12, 13, 14, 16, 17, 18, 19, 23, 24, 25,
install 16 26, 27, 30
installation 8, 16, 25
U
isopropyl alcohol 14, 22
unboxing 16
IPA 22, 23, 24
USB 22, 25, 30
K W
knob 12, 18, 22, 24, 27, 30
warranty 8, 9, 10, 16, 17, 23
L
LEDs 11, 12, 18, 19, 24, 26, 30
M
maintenance 8, 23
motor 26, 27, 30
O
operation 8, 13
P
package
packaging 16, 17, 28
power 12, 13, 16, 17, 21, 22, 23, 25, 26, 30
R
resin 10, 14, 15, 17, 18, 20, 22, 23, 24, 26, 27

Index | 29
10. Glossary
term meaning
Circular wheel The turntable sits on the circular wheel mount, which is driven by the
mount motor assembly.
Cover The hinged cover allows access to the Form Cure turntable. Double walls
insulate the cure chamber and internal surfaces reflect light.
Display The display shows status, time, temperature, and options for configuring the
Form Cure.
Display ribbon A flat, flexible cable connects the display assembly to the motherboard.
cable
Heater A 100 W heating module that can heat the chamber up to 80 °C / 176 °F .
Interlock magnets The interlock sensor detects these magnets to determine when the cover is
closed. This safety mechanism disables the heater, 405 nm LEDs, and turntable
when the cover is open.
Knob The knob is the primary interface device for the Form Cure. Turn the knob to
navigate the display menu. Press the knob to select a feature or setting.
LEDs An array of thirteen (13) 405 nm LEDs help to post-cure parts. Secondary lights
illuminate the turntable when the cover is open and during heating.
Motherboard The motherboard is the main circuitry through which all systems in the Form
Cure communicate.
Motor assembly The motor assembly rotates the turntable during the post-cure cycle.
Power supply Provides power to the Form Cure. Specifications: 24 V, 6 A
Turntable A rotating plate ensures balanced post-curing across all exposed part surfaces.
The turntable is perforated to allow light to reach all surfaces of printed parts in
the Form Cure.
USB port The Form Cure can connect to a computer via USB. The port is connected to the
motherboard and can be accessed from the back of the machine.
Index | 31