Ab183 Luxeon FX2
Ab183 Luxeon FX2
LUXEON FX2
Assembly and Handling Information
Introduction
This application brief addresses the recommended assembly and handling
procedures for LUXEON FX2. The LUXEON FX2 is designed to deliver high luminous
flux and efficacy in automotive exterior lighting applications. As a matter of principle,
LEDs require special assembly and handling precautions.
Scope
The assembly and handling guidelines in this application brief apply to the products:
PRODUCTS
In the remainder of this document, the term LUXEON FX2 refers to any product in
the LUXEON FX2 product family.
Where further differentiation between the two package size are necessary the term
LUXEON FX2 Plus refers to all family members carrying a Plus in their description.
AB183 LUXEON FX2 Application Brief ©2023 Lumileds Holding B.V. All rights reserved.
Table of Contents
     Introduction  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1
Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1. Component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. Handling Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                                                                                                                             2
            5.8 Board Handling and Bending . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                                                                             3
1. Component
        1.1 Reference Document
        The LUXEON FX2 datasheets are available upon request. Please contact your sales representative.
        1.2 Description
        The LUXEON FX2-LED consists of a single chip, combined with a phosphor converter. This LED Chip is placed on an AIN
        carrier substrate and the electrical and thermal pads are formed on the bottom side of this AlN carrier. The outside of the
        package is coated with white silicone to shield the chip from environment and to prevent light leakage to the sides (top
        emitter). The LUXEON FX2-LED includes a separate transient voltage suppressor (TVS) chip on top of the carrier substrate,
        that is covered by side coat. The TVS shall protect the emitter against electrostatic discharges (ESD). For the subset
        LUXEON FX2 Plus a dedicated thermal pad is located beneath the LED chip as can be seen in Figure 2.
Figure 1. Top view (left) and bottom view (right) of the LUXEON FX2
Figure 2. Top view (left) and bottom view (right) of the LUXEON FX2 Plus
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                          4
        Table 1. Design features by LUXEON FX2 part number
                                                                   NOMINAL
                                                                                                        LIGHT EMITTING
          PRODUCT        PRODUCT                                    DRIVE           PACKAGE SIZE                              NUMBER       ESD
                                             PART NUMBER                                                     AREA
           PHOTO        DESCRIPTION                                CURRENT             (mm)                                   OF PADS   PROTECTION
                                                                                                             (mm)
                                                                     (mA)
                                                                                                                                          Internal
                           FX2 PCA        A1F2-0591S2Axxxxx          1000         1.50 x 1.85 x 0.838        1.06 x 1.06        2
                                                                                                                                         TVS-diode
                                                                       NOMINAL                                   LIGHT
                                                                                                                              NUMBER
          PRODUCT          PRODUCT                                      DRIVE            PACKAGE SIZE           EMITTING                   ESD
                                                PART NUMBER                                                                     OF
           PHOTO          DESCRIPTION                                  CURRENT              (mm)                  AREA                  PROTECTION
                                                                                                                               PADS
                                                                         (mA)                                     (mm)
                                                                                                                                           Internal
                         FX2 Plus PCA        A1F2-0591S3Axxxxx            1000         1.92 x 2.34 x 0.838      1.06 x 1.06      3
                                                                                                                                         TVS-diode
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                          5
        1.3 Form Factor
        The dimensional design for LUXEON FX2 is outlined below in Figure 3 and for LUXEON FX2 Plus in Figure 4. The different
        dimensions, related to the type, are listed in Table 1 and Table 2. See the latest LUXEON FX2 datasheet for detailed
        dimensions and applicable tolerances.
                                                                         Optical
                                                                         Center
0.18 mm
                                                                         Package
                                                                         Center
                                                Top                                              Bottom
                                   Figure 5. Nominal optical center and geometrical package center for LUXEON FX2
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                        6
                                                                         Optical
                                                                         Center
0.46 mm
                                                                         Package
                                                                         Center
                                             Top                                               Bottom
                                Figure 6. Nominal optical center and geometrical package center for LUXEON FX2 Plus
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                      7
2. Handling Precautions
        2.1 Electrostatic Discharge (ESD) Protection
        As shown in Table 1 and 2, the LUXEON FX2 is ESD protected by an additional TVS device. This transient voltage suppressor
        (TVS) diode provides a current path for transient voltages (see Figure 7).
        Common causes of ESD inlude the direct transfer of charges from the human body or from a charged conductive object to
        the LED component. In order to test the susceptibility of LEDs to these common causes of ESDs, two different models are
        typically used:
        The LUXEON FX2 has been independently verified to successfully pass ESD tests under HBM and CDM conditions. For
        the respective test voltages of these tests please refer to the latest LED datasheets. Additional external ESD protection
        for the LED may be needed if the LED is used in non ESD-protected environments or exposed to higher ESD voltages and
        discharge energies, e.g. as described in ISO 10605 or IEC 61000-4-2 (severity level IV). For details please contact your sales
        representative.
        Machine (MM) is redundant to HBM at the device level since it produces the same failure mechanisms and the two models
        generally track each other in robustness and in failure modes produced and is therefore obsolet.
        The suction tip should be made of a soft material such as rubber to minimize the mechanical force exerted onto the top
        surface of the LED. Avoid contaminating the top side surface of the LED. Do not stick any tape on top of the light emitting
        surface, such as Kapton™- or UV-tape. A contamination with glue or its invisible constituent parts may change the LED
        performance.
        Electrical testing before assembly should be avoided. Probe tips may scratch or dent the pad surface, which may lead to
        solder issues, and damage the LED. Avoid any contact with the LED other than what is required for placement.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                             8
                                                                                                           VAC.
        Do not touch the top surface with fingers or apply any pressure to it when handling finished boards equipped with LEDs.
        Do not stack finished boards because the LEDs can be damaged by the other board outlines. In addition, do not put
        finished boards with LEDs top side down on any surface. The surface of a workstation may be rough or contaminated and
        may damage the LEDs. These warnings are shown in Figure 9.
        2.3 Cleaning
        The surface of the LED should not be exposed to dust and debris. Excessive dust and debris on the LED surface may cause
        a decrease in light output and optical behavior. It is best to keep LEDs in their original shipping reel until actual use.
        In the event that the surface requires cleaning, a compressed gas duster or an air gun with 1.4 bar (at the nozzle tip) and a
        distance of 15 cm will be sufficient to remove the dust and debris. Make sure that the parts are secured first, taking above
        handling precautions into account.
        One can also rinse with isopropyl alcohol (IPA). Do not use solvents listed in Table 12, as they may adversely react with
        the LED assembly. Extra care should be taken not to damage the housing around the LED chips. Lumileds does not
        recommend ultrasonic supported cleaning for LEDs.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                           9
3. Printed Circuit Board
        3.1 PCB Requirements
        The LED can be mounted on multi-layer FR4 printed circuit boards (PCB) or insulated metal substrates (IMS). To ensure
        optimal operation of the LED, the thermal path between the LED package and the heat sink should be optimized according
        to the application requirements. Please ensure that the PCB assembly complies to the applicable IPC standards listed
        below.
          • IPC 4761: Design Guide for Protection of Printed Board Via Structures
          • IPC 2315: Design Guide for High Density Interconnects and Micro Vias
          • IPC 2226: Design Standard for High Density Interconnect Printed Boards
        For the LUXEON FX2 Plus, Lumileds recommends a solder mask defined land pattern, as shown in Figure 11. The copper
        area can be extended as far as possible for better heat spreading, which results in lower thermal resistance. However,
        a solder mask defined pad requires good mask quality and tight registration tolerances during PCB manufacturing (see
        Chapter 3.7 “PCB Quality and Supplier” for more details).
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                         10
        For the solder mask defined land pattern, the self-alignment of the component during reflow soldering can be controlled
        well by solder mask geometry in X- and Y-direction.
Figure 11. Metal defined land pattern for LUXEON FX2 Plus
        A maximum mask registration tolerance of 50 µm between the copper trace pattern and solder mask is desirable to
        achieve optimum solder joint contact area using the recommended solder mask defined footprint as shown in Figure 10.
        If the offset between the solder mask and the copper land pattern is large, one side of electrode pads will have less solder
        joint contact area. This may affect package centering, tilting, and thermal performance and may increase risk of solder
        bridging (short circuit) and solder balling if the stencil is not properly aligned to the solder mask during printing.
        Figure 12 shows an example of the solder pad size for different registration offset levels between the copper trace pattern
        and the solder mask for LUXEON FX2 using the recommended footprint in Figure 12. Large misalignment between solder
        mask opening and copper trace will cause one of the two electrode copper land patterns to be smaller than the other.
        Depending on the PCB manufacturer capability, PCB cost consideration and customer position tolerance needs, it may be
        necessary to extend the area of the solder mask opening.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                        11
                                                 Figure 12. Solder mask registration offset to copper trace
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                  12
4. Thermal Measurement Guidelines
        4.1 Thermal Resistance
        The thermal resistance between the junction of the LED and the bottom side of the PCB depends on the following key
        design parameters of a PCB:
        Lumileds conducted simulations to evaluate the thermal performance of LUXEON FX2 on different PCB design concepts.
        Details of the simulation model are given in Figure 13. The model geometry comprises the LED on a board (metal-core
        printed circuit board or FR4 board) that is mounted on a plate Al heatsink. A thermal interface material (TIM) is assumed
        between board and heatsink. The thermal resistances junction-to-board bottom Rth,j-b,el (thermal resistance based on
        electrical input power) are calculated as Rth,j-b,el = Rth,j-b,real/(1–WPE), where WPE denotes the wall plug efficiency. The WPE is
        not constant and depends on drive condition and flux binning class. The thermal resistance Rth,j-b,real is based on thermal
        power and is obtained by Rth,j-b,real = (Tj-Tb)/Pth, where Tj is the average junction temperature, Tb the maximum temperature at
        the bottom side of the board obtained from the simulations, and Pth the thermal input power.
Simulation Details
        Simulation
          •        Model                                                             Board Thermal Conductivities
          • LED on board and plate heat sink with TIM                                   • Cu:                 390 W/(mK)
          • Simulation of heat conduction and radiation                                 • IMS dielectric:     2.2 W/(mK) or 3 W/(mK)
          • Bottom of heat sink is assumed to be ideally                                • FR4 epoxy:          0.3 W/(mK)
            heat-sunk to ambient
                                                                                        • Vias plating:       390 W/(mK)
        Heat Sink and TIM Parameters                                                    • Vias filling:       0.3 W/(mK)
          • Heat sink size: 50 mm x 50 mm x 5 mm                                        • Solder mask:        0.2 W/(mK)
          • Heat sink material:            Al – 150 W/(mK)                           Solder Parameters
          • TIM thickness: 100 µm
                                                                                        • Thickness (BLT):    90 µm
          • TIM th. cond.: 2 W/(mK)
                                                                                        • Th. conductivity:   56 W/(mK)
        Board Parameters
          • Board area:               20 mm x 20 mm
          • Board thickness:          1.0 mm (Cu-IMS) or 1.6 mm
            (Al-IMS, FR4)
          • Cu layer thickness: 70 µm
          • Solder mask:              20 µm
          • IMS diel. thickness: 75 µm or 38 µm
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                  13
                                       Figure 13. Model geometry and board parameters used for the simulation
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                    14
        Table 3a and 3b list the simulated LED-junction-to-board-bottom thermal resistances Rth,j-b,real (based on thermal power)
        and the thermal resistances Rth,j-b,el (based on electrical power) for LUXEON FX2 Plus and LUXEON FX2 on different
        board. The thermal resistances Rth,j-b,el have been calculated assuming a WPE for LUXEON FX2 CW and LUXEON Plus CW
        of 0.3, as well for LUXEON FX2 PCA and LUXEON FX2 Plus PCA of 0.25.
FR4 open vias 1.6 mm, no bottom SM 15.4 10.7 15.4 11.5
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                  15
        4.2 Close-Proximity Thermal Performance
        The For small distances between the individual LEDs, thermal crosstalk can occur, leading to enhanced junction
        temperatures. Lumileds recommends using thermally well performing boards with high-conductivity dielectric to optimize
        the thermal performance.
        Lumileds conducted thermal simulations of a 2x2 and a 2x3 LED arrangement of varying distance between the LEDs as
        schematically shown in Figure 14. The thermal resistances Rth,j-b,real of an Al-IMS board and an FR4 board with filled and
        capped vias in the thermal pad region were analyzed. The board size was 60 mm x 60 mm. The vias region in the FR4
        epoxy was modelled as a region of anisotropic thermal conductivity with an in-plane conductivity of k|| = 0.3 W/(mK) and
        an out-of-plane conductivity of k^ = 38 W/(mK), corresponding to a fractional Cu area of ~10%. This value is in line with
        the vias pattern given in Figure 13. Other board parameters are chosen as described in section 4.1 The same power was
        assigned to all LEDs in the array. The simulated thermal resistances from junction to board bottom Rth,j-b,real are given in the
        graphs in Figure 14. They have been calculated using the simulated junction temperature and the thermal power of an
        individual LED according to:
         Figure 14. (a) Simulated thermal resistance Rth,j-b,real as a function of the gap d between the LEDs for a 2x2 array configuration,
              (b) simulated thermal resistance Rth,j-b,real as a function of the gap d between the LEDs for a 2x3 array configuration.
                                    The thermal resistance values in (a) and (b) refer the power of one LED.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                               16
        4.3 Thermal Measurement Instructions
        The use of a temperature probe may be desirable to verify the overall system design model and expected thermal
        performance. Different methods exist to determine the LED temperature in terms of case temperature Tc, junction
        temperature Tj, or phosphor temperature Tph.
        Table 4 lists three methods along with the expected measurement accuracy. The more accurate a measurement is, the
        closer Tc and Tj can be designed to their maximum allowable values as specified in the LUXEON FX2 datasheets.
                Thermo sensor (e.g. thin wire thermocouple)                          ±2.0 to ±5.0 [1]                        Low          Low
                        Forward voltage measurement                                       ±0.5                               High         High
                           Infrared thermal imaging                                 ±2.0 to ±10.0 [2]                       Medium        High
        Notes for Table 4:
        1. See “Temperature Probing by Thermo Sensor” for parameters determining the measurement accuracy.
        2. See “Temperature Measurement by Infrared Thermal Imaging” for parameters determining the measurement accuracy.
        Figure 15 schematically shows the LED soldered to a PCB, including the relevant temperatures as defined for specific
        positions in the setup. Since the LED is directly soldered to the board, the case temperature is equal to the temperature
        of the solder material Tsolder. A practical way to verify the case temperature Tc is to measure the temperature Tsensor on a
        predefined sensor pad thermally close to the case by means of a thermocouple or a thermistor as shown in Figure 15.
        In these equations, Tsensor is the sensor temperature at the predefined location, Pel the electrical power of the LUXEON FX2
        emitter, Pth = Pel • (1 – WPE) the thermal power of the LUXEON FX2 emitter, Rth,c-sensor,el the thermal resistance between
        case and sensor point based on the electrical power, and Rth,c-sensor,real the thermal resistance between case and sensor
        point based on the thermal power. The thermal resistances Rth,c-sensor,real and Rth,c-sensor,el are application specific and can be
        determined with help of thermal simulations and measurements. Lumileds has determined the typical Rth,c-sensor,real and
        Rth,c-sensor,el for LUXEON FX2 on different board types (see Table 5). Please refer to section 4.1 for more detailed information
        regarding the board design parameters. The sensor has been mounted at a distance of 0.5mm to the edge of the package
        as indicated in Figure 15. The accuracy of the measurement depends on the board type, the measurement accuracy of
        the thermocouple, and the mounting position. The temperature signal at the thermo sensor measurement point is higher
        for boards with large heat spreading in the top Cu layer (typically boards with low-conductive dielectric). LED boards with
        different configuration, design, or material from the ones given in Table 5 may require additional thermal modeling or
        measurements to determine the right case-to-sensor thermal resistances.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                          17
        Table 5. Typical Rth,c-sensor,real and Rth,c-sensor,el values of different board concepts
             Double-layer FR4 board with filled and capped vias                  8.0                     5.6                8.0                6.0
               IMS with dielectric of 3 W/(mK), 38 µm thickness                  5.0                     3.5                5.0                3.7
              IMS with dielectric of 2.2 W/(mK), 75 µm thickness                 6.0                     4.2                6.0                4.5
        The forward voltage measurement uses the temperature dependence of the LED’s forward voltage Vf. The forward voltage
        after switching off the thermally stabilized system is measured and analyzed, yielding information on the LED junction
        temperature. By using a thermal model of LUXEON FX2 or the LED junction-to-case thermal resistance as indicated in the
        datasheet, the case temperature Tc can be estimated. To ensure high accuracy, a precise and fast voltage measurement
        system is needed. In addition, the relationship between forward voltage and temperature needs to be properly
        characterized for each individual LED. Please contact your sales representatives for further support in this topic.
        Infrared (IR) thermal imaging can be used to measure the surface temperature/phosphor temperature of the LED or
        the board temperature. Lumileds does not recommend using IR measurements to estimate the LED junction or case
        temperature.
        For an accurate determination of the absolute temperature via IR thermography, the determination of the exact emissivity
        value is crucial. The emissivity generally depends on material, surface properties, and temperature. It can be determined
        by heating up the unbiased device to a defined temperature that can be, for example, measured with a thermocouple.
        Then, an IR measurement can be taken of this setup, and the emissivity setting of the material of interest (typcially the
        phosphor or the board surface) can be adjusted to match the thermocouple reading. The obtained emissivity value can
        be used to evaluate the IR image of the device in operation to determine the temperature of interest. The temperature at
        which the emissivity value is determined should be similar to the temperature in operation that is to be measured. During
        IR imaging, make sure that the recorded image is not disturbed by unwanted background reflections. Due to the small
        dimensions of the LUXEON FX2, an imaging system with high magnification should be used in order to get a sufficient
        resolution of the LED in the IR image.
        Note that due to losses in the phosphor converter layer, the phosphor temperature of the LUXEON FX2 is typically higher
        than the LED junction temperature. The absolute temperature difference depends on the drive current and on the type of
        phosphor.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                                18
5. Assembly Process Recommendations and Parameters
        5.1 Solder Paste
        For reflow soldering, a standard lead free SAC solder paste (SnAgCu) with no clean flux can be used. The majority of the
        Lumileds internal testing has been conducted with the Innolot solder paste, which showed reasonable reflow and voiding
        performance for the given settings. An Innolot based solder paste can improve thermal cycling reliability performance
        under certain conditions. We recommend Heraeus F640IL Innolot in combination with Al-IMS or Cu-IMS Boards. Vacuum
        soldering equipment can be used to achieve a lower void level. Solder paste with powder type 3 is recommended for
        required stencil thickness and aperture size.
Figure 16. Stencil aperture for solder mask defined design LUXEON FX2
        For the metal defined land pattern Lumileds internal testing has been conducted with a stencil aperture of 94% of the LED
        footprint area.
Figure 17. Stencil aperture for solder mask defined design for LUXEON FX2 Plus
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                         19
        5.3 Pick and Place Nozzle
        The LUXEON FX2 is packed in a tape and reel with the light emitting surface facing upwards. Automated pick and place
        equipment provides the best handling and placement accuracy for the LUXEON FX2-LED.
Lumileds recommends taking the following general pick and place guidelines into account:
        Since LUXEON FX2 has no primary optics or lens which can act as a mechanical enclosure protection for the LED chip, the
        pick-up and placement force applied to the top of the package should be minimized and kept well controlled.
        Picking the component out of the carrier tape should be performed from a defined height position and should not apply
        forces to the component and carrier tape, as this may damage the component. The LUXEON FX2 is packed in a recess of
        the carrier tape, and the nozzle geometry must be selected accordingly to not get in contact with carrier tape (see Figure 19).
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                            20
        For the LUXEON FX2, a standard pick and place nozzle can be used, as shown in Figure 20a, 20b and 20c.
Figure 20b. Alternative ASM Siplace nozzle recommendation for LUXEON FX2
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                         21
        Figure 21 and Figure 22 show the standard pick and place nozzles from different SMT machine vendors, which can be used
        to handle the LUXEON FX2 Plus.
Figure 21. ASM Siplace nozzle recommendation for LUXEON FX2 Plus
Figure 22. Juki machine nozzle recommendation for LUXEON FX2 Plus
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                           22
        5.4 Placement Force
        In order to avoid any damage of the LED and minimize squeeze-out of solder paste, placement process needs to be tightly
        controlled. Lumileds recommends using low placement forces or a Z-height controlled placement during the pick and
        place process. The force during pick and place should not exceed 2.0 N. An additional large dynamic peak force occurs if
        the LED is placed with high Z-axis velocity at the point of touching the board and if the nozzle mass is high. Under worst
        case conditions, the LED can be damaged. For example, if large particles are underneath the LED (see Figure 23). Lower
        the Z-axis velocity if needed.
Figure 23. LED touching the board during pick and place can worst case damage the LED
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                          23
        5.6 Reflow Profile
        The LUXEON FX2-LED is compatible with standard surface-mount and lead-free reflow technologies. This greatly simplifies
        the manufacturing process by eliminating the need for adhesives and epoxies. The reflow step itself is the most critical
        step in the reflow soldering process and occurs when the boards move through the oven and the solder paste melts,
        forming the solder joints. To form good solder joints, the time and temperature profile throughout the reflow process
        must be well controlled. A temperature profile consists of three primary phases:
           1.     Preheat: the board enters the reflow oven and is warmed up to a temperature lower than the melting point of the
                  solder alloy.
           2.     Reflow: the board is heated to a peak temperature above the melting point of the solder, but below the temperature
                  that would damage the components or the board.
           3.     Cool down: the board is cooled down rapidly, allowing the solder to freeze, before the board exits the oven.
        As a point of reference, the melting temperature for SAC 305 is 217 °C, and the minimum peak reflow temperature is
        235 °C.
Lumileds successfully utilized the reflow profile in Figure 25 and listed in Table 8 for LUXEON FX2.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                                         24
        Things to watch for after reflow should include:
           1.    Solder voids — perform x-ray inspection
           2.    Solder bridge between anode and cathode
           3.    Solder balling
           4.    Any visible damage, tilt or misplacement of LED
           5.    Any contamination on light emitting area — this may impact the light output extraction or cause color shift
           6.    Functional test (open/short)
           7.    Current test, e.g. Vf at 1 mA ≥ 2.0 V
Figure 26. L1 and L2 tolerance definition. Exemplary cross section of LUXEON FX2 Plus
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                        25
        5.8 Board Handling and Bending
        The LED package handling precaution, as described in section 2.2 “Component Handling”, must also be applied when
        handling LED assemblies. For example, bending of a PCB is a common handling problem, typically seen on large boards. A
        printed circuit board may warp after reflow when layers with different CTE (coefficient of thermal expansion) are applied to
        the top and bottom of the boards. If the PCB is subsequently secured to a flat surface, a vertical force is applied to the LED
        package (see Figure 27).
        Any deformation by mounting the board and screwing it onto a heatsink or by de-paneling, like punching-off or breaking-
        off, should be kept to minimum. As a general guideline, it should be at most 2 mm of vertical deflection for every 90mm
        of FR4 PCB length. The guideline in Figure 28 should be maintained to prevent the sapphire chip, used in the LED, from
        cracking and causing device failure. Reference AEC-Q200-005 for board bending test preparation.
        This board bending test does not apply to solder joint reliability, as the ability of the solder joint to withstand this stress
        (elongation) depends on the footprint layout, solder joint thickness, solder voiding and the type of solder paste used.
Figure 27. Maximum PCB bending guideline to prevent damage to the LED package
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                              26
        5.9 Packing of Assembled LUXEON FX2 Module
        Finished boards must be protected against damage during transport. It is recommended to use a customized tray
        package, which is designed to hold the PCBs during transport (see Figure 28).
          1.    Design the tray to avoid accidently touching the LED by manual handling. Ideally, the tray only allows one way to hold
                the assembly. If there are several ways to put assemblies into the tray or take them out, a strict operator discipline
                and clear instruction on how to safely handle the assemblies is needed.
          2.    It must be designed in a way that no force from the tray or packing material is applied to the LED.
          3.    In a stack of multiple trays, the PCB should also be secured from the top. This can be done by bottom structures of
                the next tray which is put on top of the stack.
          4.    The tray should also protect the LED against movement and shaking/vibrations during transport.
Figure 28. Schematic of a good tray design. The LEDs are protected against movement and no forces are applied to the LEDs.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                       27
6. Interconnect Reliability Parameters
        The reliability of board interconnect under thermal cycling and thermal shock condition is mainly determined by thermal
        expansion of used materials. The LUXEON FX2 package is made of AlN which has a low CTE of ~4 ppm (coefficient of
        thermal expansion). The CTE mismatch between LED package and printed circuit board will lead to mechanical stress and
        cause solder fatigue or solder cracking. To achieve highest possible reliability the CTE of the board material should be as
        similar to the LED package as possible. Table 10 shows commonly used materials and their CTE.
        Also, the mechanical properties of solder material and solder thickness have an impact on interconnect reliability. Using a
        ductile material and increasing the bond line thickness will increase solder joint reliability.
The pad design of LUXEON FX2 has shown increased interconnect reliability, compared to the design of LUXEON FX2 Plus.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                            28
7. JEDEC Moisture Sensitivity Level
        JEDEC has defined eight levels for moisture sensitivity, as shown in Table 11.
                                                                                                       SOAK REQUIREMENTS
                                                  FLOOR LIFE
                LEVEL                                                                     STANDARD                    ACCELERATED EQUIVALENT 1
                                       Time on
                   6                                        30 °C / 60% RH          TOL           30 °C / 60% RH
                                      Label (TOL)
        The LUXEON FX2-LED has a JEDEC moisture sensitivity level of 1. This is the best level in the industry and within the JEDEC
        J-STD-020D.1 standard. The customer no longer needs to be concerned about bake out times and floor life. No bake out
        time is required for a moisture sensitivity level of 1.
        Moisture sensitivity level 1 allows the device to be reflowed three times under the specifications as described in the
        respective LUXEON FX2 datasheets.
        The silicone overcoat is gas permeable. Consequently, oxygen and volatile organic compound (VOC) gas molecules can
        diffuse into the silicone overcoat. VOCs may originate from adhesives, solder fluxes, conformal coating materials, potting
        materials and even some of the inks that are used to print the PCBs. Some VOCs and chemicals react with silicone and
        produce discoloration and surface damage. Other VOCs do not chemically react with the silicone material directly but
        diffuse into the silicone and oxidize during the presence of heat or light. Regardless of the physical mechanism, both cases
        may affect the total LED light output. Since silicone permeability increases with temperature, more VOCs may diffuse into
        and/or evaporate out from the silicone.
        Careful consideration must be given to whether the LEDs are enclosed in an “air tight” environment or not. In an “air tight”
        environment, some VOCs that were introduced during assembly may permeate and remain in the silicone overcoat.
        Under heat and “blue” light, the VOCs inside the silicone overcoat may partially oxidize and create a silicone discoloration,
        particularly on the surface of the LED where the flux output is the highest. In an air rich or “open” air environment, VOCs
        have a chance to leave the area (driven by the normal air flow). Transferring the devices, which were discolored in the
        enclosed environment back to “open” air, may allow the oxidized VOCs to diffuse out of the silicone overcoat and may
        restore the original optical properties of the LED.
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                                            29
        Determining suitable threshold limits for the presence of VOCs is very difficult since these limits depend on the type of
        enclosure used to house the LEDs and the operating temperatures. Also, some VOCs can photo-degrade over time.
        Table 12 provides a list of commonly used chemicals that should be avoided as they may react with the silicone material.
        Note that Lumileds does not warrant that this list is exhaustive since it is impossible to determine all chemicals that may
        affect LED performance.
        The chemicals in Table 12 are typically not directly used in the final products that are built around the LEDs. However,
        some of these chemicals may be used in intermediate manufacturing steps (e.g. cleaning agents). Consequently, trace
        amounts of these chemicals may remain on sub-components, such as heatsinks. Lumileds, therefore, recommends the
        following precautions when designing your application:
        When designing secondary lenses to be used over an LED, provide a sufficiently large air-pocket and allow for “ventilation”
        of this air away from the immediate vicinity of the LED. Use mechanical means of attaching lenses and circuit boards as
        much as possible. When using adhesives, potting compounds and coatings, carefully analyze its material composition and
        do thorough testing of the entire fixture under High Temperature Over Life (HTOL) conditions.
Table 12. List of commonly used chemicals that may damage the silicone overcoat of the LED
AB183 LUXEON FX2 Application Brief 20230417 ©2023 Lumileds Holding B.V. All rights reserved.                                          30
About Lumileds
Companies developing automotive, mobile, IoT and illumination lighting applications need a partner who can collaborate with
them to push the boundaries of light. With over 100 years of inventions and industry firsts, Lumileds is a global lighting solutions
company that helps customers around the world deliver differentiated solutions to gain and maintain a competitive edge. As the
inventor of Xenon technology, a pioneer in halogen lighting and the leader in high performance LEDs, Lumileds builds innovation,
quality and reliability into its technology, products and every customer engagement. Together with its customers, Lumileds is
making the world safer, better and more beautiful—with light.
©2023 Lumileds Holding B.V. All rights reserved.         Neither Lumileds Holding B.V. nor its affiliates shall be liable for any kind of loss of data or any other damages,
LUXEON is a registered trademark of the Lumileds         direct, indirect or consequential, resulting from the use of the provided information and data. Although Lumileds
Holding B.V. in the United States and other countries.   Holding B.V. and/or its affiliates have attempted to provide the most accurate information and data, the materials
                                                         and services information and data are provided “as is,” and neither Lumileds Holding B.V. nor its affiliates
lumileds.com                                             warrants or guarantees the contents and correctness of the provided information and data. Lumileds Holding
                                                         B.V. and its affiliates reserve the right to make changes without notice. You as user agree to this disclaimer and
                                                         user agreement with the download or use of the provided materials, information and data. A listing of Lumileds
                                                         product/patent coverage may be accessed at lumileds.com/patents.
AB183 LUXEON FX2
Application Brief 20230417