AUTOMOTIVE
SignalSure 250
High power SMD solution
SignalSure 250 is a compact, surface-mount, high power LED signaling
solution that delivers an elevated standard of light output, flux density,
and color uniformity. SignalSure’s robust design structure, coupled with
high performance specifications, ensures high quality and reliability.
SignalSure 250 is AEC-Q101D qualified.
SignalSure 250 is available in the following color wavelengths:
      –– Red Orange (615nm)
      –– Super Red (630nm)
      –– Super Red (635nm)
  FEATURES AND BENEFITS                                                                   PRIMARY APPLICATIONS
  Higher drive current capability for increased flux performance                          Rear Fog
  Low thermal resistance for better hot lumen performance                                 Stop/Tail
  Same footprint as SignalSure75 and SignalSure150 to increase PCB flexibility
  AEC-Q101D qualified
                                                                                                                 RoHS
                                                                                                                 COMPLIANT
DS148 SignalSure 250 Product Datasheet ©2015 Lumileds Holding B.V. All rights reserved.
Table of Contents
General Product Information  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
        Product Test Conditions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
        Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
        Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Performance Characteristics  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
        Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
        Optical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
        Electrical and Thermal Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
        Absolute Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Characteristic Curves  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
        Spectral Power Distribution Characteristics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
        Light Output Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
        Forward Current Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
        Radiation Pattern Characteristics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
        Operating Limits Characteristics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Product Bin and Labeling Definitions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
        Designing with SignalSure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
        Decoding Product Bin Labeling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
        Luminous Flux Bins  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
        Color Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
        Forward Voltage Bins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Mechanical Dimensions .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9
Reflow Soldering Guidelines  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
        JEDEC Moisture Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
        Solder Pad Design  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Packaging Information .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 12
        Pocket Tape Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
        Reel Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
        Product Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                                                                                                                                                             i
General Product Information
Product Test Conditions
SignalSure 250 LEDs are tested and binned using a 20ms monopulse (MP) at 250mA drive current, junction temperature, Tj, of 25ºC.
Part Number Nomenclature
Part numbers for SignalSure 250 follow the convention below:
        A 1 D L – B C C C L 1 2 D E F G 0 0
Where:
        B        –   designates color (O=Red Orange and S=Super Red)
        C C C–       designates minimum dominant wavelength (612=612nm, 627=627nm and 632=632nm)
        D        –   designates minimum flux bin (See Product Bin and Labeling section)
        E        –   designates the flux bin range (3=3 subsequent flux bins including the minimum bin)
        F G      –   designates forward voltage range in which F is the minimum Vf bin and G is the maximum Vf bin
                     (See Product Bin and Labeling Definitions section)
Therefore, the following part number is used for a SignalSure 250 Red Orange, 615nm minimum wavelength, luminous flux range
of 36 lumens to 43 lumens and forward voltage range of 2.07 volts to 2.79 volts:
        A 1 D L – O 6 1 5 L 1 2 U 3 A F 0 0
Environmental Compliance
Lumileds LLC is committed to providing environmentally friendly products to the solid-state lighting market. SignalSure 250 is
compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the
RoHS Directive 2011/65/EU and REACH Regulation (EC) 1907/2006. Lumileds LLC will not intentionally add the following restricted
materials to its products: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated
diphenyl ethers (PBDE).
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                                 2
Performance Characteristics
Product Selection Guide
Table 1. Product selection for SignalSure 250 at 20ms MP, 250mA, Tj=25°C.
                                                                                  DOMINANT WAVELENGTH [1,2]
                             COLOR                                                                                                                   PART NUMBER
                                                                                           (nm)
                          Red Orange                                                                 615                                               A1DL - O612L
                           Super Red                                                                 630                                               A1DL - S627L
                           Super Red                                                                 635                                               A1DL - S632L
Notes for Table 1:
1. Dominant wavelength is derived from the CIE 1931 Chromaticity diagram and represents perceived color.
2. Lumileds maintains a tolerance of ±1nm for dominant wavelength measurements.
Optical Characteristics
Table 2. Typical optical characteristics for SignalSure 250 at 20ms MP, 250mA, Tj=25°C.
                                                                               TYPICAL TOTAL INCLUDED ANGLE [1]                              TYPICAL VIEWING ANGLE [2]
                       PART NUMBER
                                                                                             θ0.90V                                                     2θ1/2
                         A1DL - O612L                                                               140°                                                   110°
                         A1DL - S627L                                                               140°                                                   110°
                         A1DL - S632L                                                               140°                                                   110°
Notes for Table 2:
1. Total angle at which 90% of total luminous flux is captured.
2. Viewing angle is the off axis angle from lamp center line where the luminous intensity is ½ of the peak value.
Electrical and Thermal Characteristics
Table 3. Electrical and thermal characteristics for SignalSure 250 at 20ms MP, 250mA, Tj= 25°C.
                                          PARAMETER                                                                                      PERFORMANCE
                                       Forward Voltage, Vf                                                                                   2.6V
                 Electrical Thermal Resistance, Rth j-c electr        [2]
                                                                            (Maximum)                                                       25°C/W
                     Real Thermal Resistance, Rth j-c real      [3]
                                                                      (Maximum)                                                             33°C/W
                               Temperature Coefficient of Vf ,
                                                                                                                                           -3.5mV/°C
                               If = 250mA, 10°C ≤ Tc ≤ 115°C
Notes for Table 3:
3. All values are typical unless otherwise stated.
4. Rth j-c electr: Electrical thermal resistance (junction to case).
5. Rth j-c real: Real thermal resistance (junction to case) with wall plug efficiency included. Reference JESD51-51, JESD51-14, 4.1.3.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                                                                         3
Absolute Ratings
Table 4. Absolute ratings for SignalSure 250.
                                     PARAMETER                                                                                 PERFORMANCE
                            Minimum DC Forward Current                                                                                10mA
                           Maximum DC Forward Current                                                                                300mA
                         Maximum Junction Temperature           [1]
                                                                                                                                     135°C
                  Operating Case Temperature at Test Current [1]                                                                -40°C to 115°C
              Operating Case Temperature at Maximum Current [1]                                                                 -40°C to 115°C
                                 Storage Temperature                                                                            -40°C to 115°C
                                Soldering Temperature                                                                         JEDEC 020c 260°C
                               Allowable Reflow Cycles                                                                                  3
                            Minimum ESD performance [2]                                                            2kV HBM (Class 2), 1kV CDM (Class III)
                                  Reverse Voltage (Vr)                                                                                -10V
Notes for 4:
1. Proper current derating must be observed to maintain junction temperature below the maximum, so that the LED is maintained below the maximum rated operating case temperature.
   SignalSure LEDs driven at or above the maximum rated operating case temperature may have shorter lifetime.
2. Measured using human body model (per ANSI/ESDA/JEDEC JS-001-2010) and charged device model (per JESD22-C101F).
Characteristic Curves
Spectral Power Distribution Characteristics
                        Figure 1: Typical normalized power vs. wavelength for SignalSure 250 at 20ms MP, 250mA, Tj=25ºC.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                                                                                    4
Light Output Characteristics
                 Figure 2: Typical normalized light output vs. junction temperature for SignalSure 250 at 20ms MP, 250mA.
                          Figure 3: Typical normalized light output vs. forward current for SignalSure 250 at Tj=25ºC.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                            5
Forward Current Characteristics
                             Figure 4a: Typical forward current vs. forward voltage for SignalSure 250 at Tj=25ºC.
                            Figure 4b. Typical forward voltage shift vs. junction temperature for SignalSure 250 at
                                                       20ms MP, specified test current.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                      6
Radiation Pattern Characteristics
                                                  Figure 5: Typical radiation pattern for SignalSure 250 at 20ms MP, 250mA.
Operating Limits Characteristics
                                            350
                                            300
                                            250
                      Forward Curent [mA]
                                            200
                                            150
                                            100
                                            50
                                                                            Do not use below 10mA
                                              0
                                                  0          20          40           60          80          100         120
                                                                     Case Temperature [°C]
                                              Figure 6: Maximum forward current vs. case temperature for SignalSure 250.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                                7
Product Bin and Labeling Definitions
Designing with SignalSure
Flux bins supportable for car programs depend on product color and program start- and end-of-production date. Flux
roadmaps by year and product color are maintained and available from the sales representative. Please contact your local sales
representative to request the flux bin range with best supportability for program timing.
Decoding Product Bin Labeling
In the manufacturing of semiconductor products, there are variations in performance around the average values given in the
technical datasheets. For this reason, Lumileds bins the LED components for luminous flux, color and forward voltage.
SignalSure 250 LEDs are labeled using a 3-digit CAT code following the format below:
         A B C
         A       –       designates luminous flux bin (example: J=15 lumens to 18 lumens)
         B       –       designates color code (example: 3=612nm to 618nm)
         C       –       designates forward voltage bin (example: B=2.19V to 2.31V)
Luminous Flux Bins
Table 5 lists the standard photometric luminous flux bins for SignalSure 250 emitters. Product availability in a particular bin varies
by color and platform start-of-production date. Contact your local sales representative for best supportability of programs.
Table 5. Luminous flux bin definitions for SignalSure 250 at 20ms MP, 250mA, Tj=25°C.
                                                                                            LUMINOUS FLUX (lm)
                           BIN
                                                                           MINIMUM                               MAXIMUM
                             H                                               12.0                                  15.0
                              J                                              15.0                                  18.0
                             M                                               18.0                                  21.0
                             N                                               21.0                                  25.0
                             P                                               25.0                                  30.0
                             R                                               30.0                                  36.0
                             U                                               36.0                                  43.0
                             W                                               43.0                                  52.0
                             X                                               52.0                                  62.0
Notes for Table 5:
1. Lumileds maintains a tolerance of ±10% on luminous flux measurements.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                                     8
Color Codes
Table 6. Color code definitions for SignalSure 250 at 20ms MP, 250mA, Tj=25°C.
                                                                                               DOMINANT WAVELENGTH (nm)
                             CODE
                                                                                    MINIMUM                               MAXIMUM
                                3                                                        612                                618
                                4                                                        627                                632
                                5                                                        632                                638
Notes for Table 6:
1. Lumileds maintains a tolerance of ±1nm on dominant wavelength measurements.
Forward Voltage Bins
Table 7. Forward voltage bin definitions for SignalSure 250 at 20ms MP, 250mA, Tj=25°C.
                                                                                               FORWARD VOLTAGE (V)
                        BIN
                                                                               MINIMUM                                MAXIMUM
                         A                                                       2.07                                     2.19
                         B                                                       2.19                                     2.31
                         C                                                       2.31                                     2.43
                         D                                                       2.43                                     2.55
                         E                                                       2.55                                     2.67
                         F                                                       2.67                                     2.79
Notes for Table 7:
1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements.
Mechanical Dimensions
                                                        Figure 7: Mechanical dimensions for SignalSure 250.
Notes for Figure 7:
1. Drawings are not to scale.
2. All dimensions are in millimeters.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                                    9
Reflow Soldering Guidelines
                                  Figure 8: Visualization of the acceptable reflow temperature profile as specified in Table 8.
Table 8. Reflow profile characteristics for SignalSure 250.
                                     PROFILE FEATURE                                                                              LEAD FREE ASSEMBLY
                                  Ramp-Up Rate (Tsmax to Tp)                                                                      3°C / second maximum
                             Minimum Preheat Temperature (Tsmin)                                                                           150°C
                             Maximum Preheat Temperature (Tsmax)                                                                           200°C
                                  Preheat Time (tsmin to tsmax)                                                                     60 to 180 seconds
                                  Liquidus Temperature (TL)                                                                                217°C
                         Time Maintained Above Temperature TL (tL)                                                                  60 to 150 seconds
                             Peak / Classification Temperature (Tp)                                                                        260°C
                         Time Within 5°C of Actual Temperature (tp)                                                                 20 to 40 seconds
                                       Ramp-Down Rate                                                                             6°C / second maximum
                               Time 25°C to Peak Temperature                                                                       8 minutes maximum
Notes for Table 8:
1. All temperatures refer to the application Printed Circuit Board (PCB), measured on the surface adjacent to the package body.
JEDEC Moisture Sensitivity
Table 9. Moisture sensitivity levels for SignalSure 250.
                                                                        FLOOR LIFE [1]                                             SOAK REQUIREMENTS STANDARD
                    LEVEL
                                                            TIME                           CONDITIONS                               TIME                 CONDITIONS
                         2                                 1 Year                         ≤30°C / 60% RH                      168 Hours +5 / -0          85°C / 60% RH
Notes for Table 9:
1. Shelf life 2 years.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                                                                         10
Solder Pad Design
                                                 Figure 9: Recommended solder pad layout for SignalSure 250.
Notes for Figure 9:
1. The drawing shows the recommended SignalSure 250 layout on Printed Circuit Board (PCB).
2. All dimensions are in millimeters.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.               11
Packaging Information
Pocket Tape Dimensions
                                               Figure 10: Pocket Tape dimensions for SignalSure 250.
Reel Dimensions
                                                   Figure 11: Reel dimensions for SignalSure 250.
Notes for Figures 10 and 11:
1. Drawings are not to scale.
2. All dimensions are in millimeters.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.       12
Product Labeling
SignalSure 250 LEDs are packaged in moisture barrier bags on reels. Both moisture barrier bag and reels have printed
information providing part numbers with CAT codes that indicate luminous flux bin, color bins and forward voltage bins.
                                                 Figure 12: Example of a moisture barrier bag label.
                                                     Figure 13: Example of a product reel label.
DS148 SignalSure 250 Product Datasheet 20151116 ©2015 Lumileds Holding B.V. All rights reserved.                          13
About Lumileds
Lumileds is the global leader in light engine technology. The company develops, manufactures and distributes groundbreaking
LEDs and automotive lighting products that shatter the status quo and help customers gain and maintain a competitive edge.
With a rich history of industry “firsts,” Lumileds is uniquely positioned to deliver lighting advancements well into the future by
maintaining an unwavering focus on quality, innovation and reliability.
To learn more about our portfolio of light engines, visit lumileds.com.
©2015 Lumileds Holding B.V. All rights reserved.                Neither Lumileds Holding B.V. nor its affiliates shall be liable for any kind of loss of data or
LUXEON is a registered trademark of the Lumileds Holding B.V.   any other damages, direct, indirect or consequential, resulting from the use of the provided
in the United States and other countries.                       information and data. Although Lumileds Holding B.V. and/or its affiliates have attempted to
                                                                provide the most accurate information and data, the materials and services information and data
lumileds.com                                                    are provided “as is,” and neither Lumileds Holding B.V. nor its affiliates warrants or guarantees
                                                                the contents and correctness of the provided information and data. Lumileds Holding B.V. and its
                                                                affiliates reserve the right to make changes without notice. You as user agree to this disclaimer
                                                                and user agreement with the download or use of the provided materials, information and data.
DS148 SignalSure 250
Product Datasheet 20151116