0% found this document useful (0 votes)
20 views2 pages

Limit Switch Contact Block Details

Uploaded by

fredd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views2 pages

Limit Switch Contact Block Details

Uploaded by

fredd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product data sheet XE2NP2131

Characteristics limit switch contact block - 2NO - slow-break,


simultaneous
Product availability : Non-Stock - Not normally stocked in distribution facility

Price* : 34.90 USD

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product OsiSense XC
Series name Standard format
Product or component type Limit switch contact block
Device short name XE2N
Associated body ZCD28
ZCKJ8
ZCKJ8D
ZCKL8
ZCKM8
ZCKS8
ZCP28
Number of poles 2
Contacts type and composition 2 NO
Contact operation Slow-break, simultaneous

Complementary
Product compatibility XCKD
XCKJ
XCKL
XCKM
XCKP
XCKS
Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Contacts insulation form Zb
Contacts material Silver plated contacts
Positive opening Without
Minimum actuation speed 6 m/min
Contact code designation A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A

Jan 4, 2019
1
Resistance across terminals < 25 mOhm conforming to IEC 60255-7 category 3
[Ui] rated insulation voltage 300 V conforming to CSA C22.2 No 14
500 V degree of pollution 3 conforming to IEC 60947-1
300 V conforming to UL 508
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection 10 A by gG cartridge fuse
Electrical durability 5000000 cycles, DC-13 120 V, 7 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC
60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 13 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC
60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 9 W, operating rate: < 60 cyc/mn, load factor: 0.5 conforming to IEC
60947-5-1 appendix C

Ordering and shipping details


Category 22449 - LIMIT SWITCHES,ACCESSORIES
Discount Schedule T
GTIN 00785901291688
Nbr. of units in pkg. 1
Package weight(Lbs) 5.0000000000000003E-2
Returnability Y
Country of origin ID

Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 0851 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product end of life instructions Need no specific recycling operations
California proposition 65 WARNING: This product can expose you to chemicals including:
- - - - - - - Substance 1 Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and
- - - - - - - Substance 2 Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other
reproductive harm.
- - - - - - - More information For more information go to www.p65warnings.ca.gov

Contractual warranty
Warranty period 18 months