Molded Case Circuit Breakers

SPEEDFAXTM 2017

contents
7 Section

What’s New in Circuit Breakers 7-3 – 7-4


Federal Specifications Classification 7-5
Dual Function Reference Guides 7-6 – 7-18
Circuit Breaker Load Center Breakers
Arc Fault and Ground Fault Breakers 7-19
QP, 1 Inch Breakers 7-20
QT, ½ Inch Breakers 7-21
Special Application Breakers 7-22
QD ¾ Inch Breakers 7-23
Main and Branch Breakers 7-24 – 7-25
Circuit Breaker Dimension Drawings 7-26
Circuit Breaker Lug Data 7-27
Surge Protection 7-28
Panelboard Mounted Circuit Breakers
NGB Circuit BL 240V Breakers 7-29
Breakers BL 240V Arc Fault and Ground Fault Breakers 7-30
Special Application 240V Panelboard Mounted Breakers 7-31
BQD 100A Frame 480/277V Breakers 7-32
GB 125A Frame 600/347V Breakers 7-33
NGB2 125A Frame 600/347V Breakers 7-34
Internal Accessories for BQD and NGB Breakers 7-35
3VA41 125A Frame 600/347V Breakers 7-36 – 7-37
General Application Circuit Breakers
BQ 240V Breakers 7-38
BQXD 240V DIN Rail Mounting Breakers 7-39
QR250 Frame 240V Breakers 7-40
CQD 100A Frame 480/277V Breakers 7-42
GG 125A Frame 600/347V Breakers 7-43
Internal Accessories for CQD and NGG Breakers 7-44

7
3VA Molded Case Circuit Breakers
Catalog Numbering System 7-45

CIRCUIT BREAKERS
MOLDED CASE
QR Circuit Breakers 3VA51 125A Thermal-magnetic Trip Circuit Breakers 7-46 – 7-49
3VA61 150A Electronic Trip Circuit Breakers 7-50 – 7-53
3VA52 250A Thermal-magnetic Trip Circuit Breakers 7-54 – 7-57
3VA62 250A Electronic Trip Circuit Breakers 7-58 – 7-61
3VA53 400A Thermal-magnetic Trip Circuit Breakers 7-62 – 7-63
3VA63 400A Electronic Trip Circuit Breakers 7-64 – 7-66
3VA 3VA54 600A Thermal-magnetic Trip Circuit Breakers 7-67
molded 3VA64 600A Electronic Trip Circuit Breakers 7-68 – 7-70
case
circuit
3VA Molded Case Switch and Motor Circuit Protector 7-71
breakers 3VA Internal Accessories 7-73
3VA Breaker Operators 7-74 – 7-79
3VA Connection Technology 7-80 – 7-86
3VA Plug-in and Draw-out Technology 7-87 – 7-89
3VA Communication and Testing/Commissioning Devices 7-90 – 7-93
3VA Accessories and Electrical Requirements 7-94 – 7-99
(continued on next page)
Scan to connect
online to the
most up-to-
date version of
this Section of
SPEEDFAX.

(Section was last modified on 02/12/20) Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-1
Molded Case Circuit Breakers
SPEEDFAXTM 2017

contents
Sentron Thermal Magnetic and Electronic Circuit Breakers
7 Section

Catalog Numbering System 7-100


ED 125A Frame 600V Breakers and Internal Accessories 7-101 – 7-103
FD 250A Frame 600V Breakers and Internal Accessories 7-104 – 7-106
JD/SJD 400A Frame Breakers and Internal Accessories 7-107 – 7-110
LD/SLD 600A Frame Breakers and Internal Accessories 7-111 – 7-114
LMD 800A Frame Breakers and Internal Accessories 7-115 – 7-117
MD/SMD 800A Frame Breakers and Internal Accessories 7-118 – 7-121
ND/SND 1200A Frame Breakers and Internal Accessories 7-122 – 7-125
PD/SPD 1600A Frame Breakers and Internal Accessories 7-126 – 7-128
RD 2000A Frame Breakers and Internal Accessories 7-129
Magnetic Trip Only – ETI Motor Circuit Protectors 7-130 – 7-132
Adjustable Instantaneous Magnetic Trip Settings 7-133 – 7-135
Molded Case Switch – Circuit Disconnect 7-136 Sentron Sensitrip
Digital Solid State Sentron Sensitrip IV Series Trip Units 7-137 – 7-138
WL Power Circuit Breakers 7-139 – 7-142
Lug Information 7-143 – 7-145
Breaker Modifications 7-146
Internal Accessories – Feature Combinations 7-147
External Accessories 7-150 – 7-155
Unusual Operating Conditions 7-156 – 7-157
VL Thermal Magnetic and Electronic Circuit Breakers
Catalog Numbering System 7-159 –
7-160
Technical Overview 7-161 –
7-162
Trip Unit Overview 7-163 –
7-164
DG 150A Frame and Internal Accessories 7-165 –
7-168
FG 250A Frame and Internal Accessories 7-169 –
7-172
JG 400A Frame and Internal Accessories 7-173 –
7-176
LG 600A Frame and Internal Accessories 7-177 –
7-180
7

MG 800A Frame and Internal Accessories 7-181 –


7-184
NG 1200A Frame and Internal Accessories 7-185 –
7-188
MOLDED CASE
CIRCUIT BREAKERS

PG 1600A Frame and Internal Accessories 7-189 –


7-191
Molded Case Switch 7-192
Motor Circuit Protector 7-193
VL 600 Volt DC Circuit Breakers 7-194
External Accessories 7-195 – 7-207
Accessory Locations 7-208
Suffix for Factory Mounted Internal Accessories 7-209
Technical Data 7-210 – 7-211
Unusual Operating Conditions 7-212 – 7-213
General Technical
Series Short Circuit Ratings 7-214 – 7-224
Sentron IEC 94702 AC Interrupting Ratings 7-225
Typical Specifications 7-226
Superseded Circuit Breakers 7-227 – 7-229

7-2 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/18

Molded Case Circuit Breakers


Introduction

What’s new in molded case circuit breakers:


New Sentron Sensitrip
Sentron Sensitrip IV ETU Circuit Breakers with Integrated DAS /
Maintenance Mode
Design enhancements include:
n Upgraded ETU for NEC 240.87 code compliance (Arc Energy Reduction)

n Frame ratings from 400A to 1600A

n Identical footprint, kAIC ratings and accessory offering as legacy


Sensitrip III ETU breakers to ease integration / retrofit
n Maintenance mode versions require customer-supplied 24V external
power supply, maintenance switch and light

The New Siemens QR Circuit Breaker


Implemented in load centers, panelboards, switchboards, meter centers,
and modular metering, the new QR breaker is the same form-factor/
mounting as QJ breaker for easy retrofit. The new
Siemens
Design enhancements include:
3VA molded
n Trip unit ratings from 100A to 250A. case circuit
n Field installable internal accessories – breakers
shunt trip, aux switch or shunt/aux combo.
n Two accessory pockets in 3-pole breakers.
One accessory pocket in 2-pole breakers.
n High in-rush current capability (450%).

n Push-to-trip button. n 125A and 250A Thermal Magnetic


Trip breakers
n 150A thru 600A Electronic Trip
Circuit Breakers

7
The Dual Function Circuit Breaker combines n Extensive and flexible accessories
GFCI and AFCI, protecting against both Arc Common internal accessories for

CIRCUIT BREAKERS
MOLDED CASE
n
Faults and Ground Faults. This, along with the the entire breaker family
new Self-Test & Lockout feature, makes it the
first in class in electrical safety for homeowners. n Power metering with the series-8
LCD electronic trip
n Faster Installation
n Illuminated rotary handles show
n Cost savings
switch position
n Smaller Device
n Smaller footprint than Sentron or
n Self Test & Lockout feature as required by VL breakers
UL 943 effective June 2015 n Enhanced Tools and Resources

The Siemens GG circuit breaker is a compact, industrial


design thermal magnetic breaker with valuable features
for the global markets. These features include a design
that meets multi-national standards, is suitable for DIN
rail or base mounting without the need for adapters,
and includes UL listed field installable accessories. The
GG also has an over center toggle mechanism that is
trip free and uses repulsion contact arm construction.
Therefore, should a short circuit or tripping condition
occur, the contacts are forced apart and the breaker
cannot be held closed by means of the handle. NGB NGG HGG LGG

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-3


Molded Case Circuit Breakers
Introduction

Ordering The smaller frames (QJ, ED and below)


do not have removable trip units, and
In the FD through RD frames, you may consequently are shipped only as
order molded case circuit breakers three assembled products. To add lugs,
basic ways: see the ordering instructions on
b As separately ordered frames, trip each product’s­catalog page.
units and lugs
b As frame, trip unit and lugs ordered as
one catalog number and shipped
unassembled or assembled
b As Frame and Trip Unit shipped
assembled and with the trip unit made
non-removable, in compliance with UL
489 requirements that to be reverse
fed the circuit breaker must not have
an interchangeable trip unit.
These two options are described in the
following:
Components Ordered Separately
To get the components for a 3-pole, 400
Amp standard interrupting circuit breaker,
you would order the frame (JD63F400),
the trip unit (JD63T400) and six lugs
(TA2J6500). This option is normally
useful only if you stock and use large 500V DC Wiring Configuration
volumes of product and wish to reduce
your inventory cost. You may stock, for Connecting Breakers for DC
example, a smaller number of frames Application
(JD63F400) and a variety of trip units
Most Siemens thermal magnetic trip
(JD63T300, JD63T350, etc.) and
MCCBs are applicable on direct current
assemble breakers as you need them.
(dc) systems. Generally, for 250 V dc
Frame, Trip Unit and Lugs systems a two pole breaker is used,
Ordered Together with one pole on each leg of the supply
If you order the catalog number circuit. For three pole breakers applied on
JD63B400, you will receive a frame, a 500 V undergrounded DC systems, it is
7

trip unit and 6 lugs in separate packages. important to connect the power supply
By suffixing this number with “L” (e.g. “zig-zag” through the breaker as shown
MOLDED CASE
CIRCUIT BREAKERS

JD63B400L), you will receive frame, trip in the figure below. This assures that the
unit and lugs assembled in one container. Voltage between phases on the breaker
Pursuant to UL 489, a product ordered terminals is uniformly distributed.
thus will have the markings “LINE” and See below for an alternative connection
“LOAD”, and may not be “reverse fed” diagram. For a list of Sentron breakers
(with power flowing from the “OFF” end with the DC ratings, please refer to
of the breaker toward the “ON” end). pages 7-12 to 7-16.
Non-Interchangeable Trip Breakers
If you place an “X” after the frame size
designator (e.g. JXD63B400), you will 300 V 300 V
receive a frame and trip unit assembled, MAX. MAX.
with the trip unit made non-removable.
If you suffix an “L” to this catalog
number (e.g. JXD63B400L), you will
receive the breaker, non-removable trip
unit and lugs assembled. Unless you Load/Carga/
anticipate a specific need to change the Charge
breaker’s ampere rating in the future,
this is the preferred ordering method, as
the products are assembled to Siemens’
specifications in our factories. These
breakers are suitable for use reverse fed
according to UL 489, since the trip unit is
not removable.

7-4 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/18

Molded Case Circuit Breakers


Federal Specification Classification Reference

W-C-375C/GEN
Interrupting Rating Breaker Type
Symmetrical (All Circuit Breakers Meet or Exceed
Class Amperesa Volts AC 60HZ Poles Range of Current Tripc the Indicated Class Level)
10ab 5,000 120/240 1 or 2 15–100 QP, BQ, QT, BL
10b 5,000 240 2 or 3 15–100 QP, BQ, BQD, CQD, BL
11a 7,500 120 1 15–100 QP, BQ, BQD, CQD, BL
11b 7,500 240 2 or 3 15–100 QP, BQ, BQD, CQD, BL
12ab 10,000 120/240 1 or 2 15–100 QP, BQ, QT, ED2, BL
12b 10,000 240 2 or 3 15–225 QP, BQ, QJ2, ED2, BQD, CQD, BL
12c 10,000 277 1 15–100 bqd, cqd, NGG, NGB, NEG, NEB
13a 14,000 277 1 15–100 ed4, bqd, cqd, NGG, NGB, NEG, NEB
13b 14,000 277/480 1, 2, or 3 15–100 ed4, bqd, cqd
14a 22,000 120/240 1 or 2 15–100 qph, bqh, blh
14b 22,000 240 2 or 3 70–400 qjh2, qj2-h, bqh, bqd, cqd, blh
15a 65,000 120/240 1 or 2 15–100 hqp, hbq, ed4, hed4, NGG, NGB
ed6, ed4, fxd6, fd6, hed4, bqd, cqd, hqj2h,
15b 65,000 240 2 or 3 15–225
NGG, NGB, NEG, NEB
16a 100,000 480 2 or 3 15–225 cfd6, ced6
16b 100,000 600 2 or 3 15–600 ced6, cfd6, cjd6, scjd6, cld6, scld6
17a 200,000 600 2 or 3 70–2000 —
18,000 240
18a 14,000 480 2 or 3 15–125 ed6, hed6, hhed6
14,000 600
22,000 240
19a 18,000 480 2 or 3 70–225 fxd6, fd6, cfd6, hfd6
14,000 600
25,000 240
20a 22,000 480 2 or 3 70–225 fxd6-a, fd6-a, cfd6, hfd6
22,000 600
hfd6, cfd6, jxd6(A), JD6(A), SJD6-B, hjd(a),
42,000 240 hjxd6(a), hhjd6, SHJD6-B, cjd6, SCJD6-B,
21a 30,000 480 2 or 3 70–800 lxd6(a), ld6(a), SLD6-B, hld6(a), hlxd6(a),
22,000 600 hhld6, SLD6-B, SHLD6-B, cld6, SCLD6-B,
lmd6, lmxd6, hlmd6, hlmxd6, md6, mxd6,
SMD6-B, hmd6, hmxd6, SHMD6-B, cmd6, SCMD6-B
65,000 240
22a 25,000 480 2 or 3 15–125 ced6, ed6, hed6, hhed6, fxd6-a, fd6-a
18,000 600

7
HHED6, FXD6-A, FD6-A, hfd6, hhfd6, cfd6,
Jd6(a), jxd6(a), SJD6-B, hjd6(a), hjxd6(a),
SHJD6-B, hhjd6, hhjxd6, cjd6, SCJD6-B,

CIRCUIT BREAKERS
MOLDED CASE
65,000 240 lxd6(a), ld6(a), SLD6-B, hld6(a), hlxd6(a),
23a 35,000 480 2 or 3 70–1200 SHLD6-B, hhld6, hhlxd6, cld6, SCLD6-B,
25,000 600 lmd6, lmxd6, hlmd6, hlmxd6, md6, mxd6,
SMD6-B, hmd6, hmxd6, SHMD6-B, cmd6, SCMD6-B,
nd6, nxd6, snd6-B, hnd6, hnxd6, shnd6-B,
cnd6, scnd6-B
65,000 240
PD6, PXD6, HPD6, HPXD6, CPD6
24a 50,000 480 2 or 3 1200–2000
RD6, RXD6, HRD6, HRXD6, SPD6-B, SHPD6-B
42,000 600
125,000 240
HHLD6, CLD6, CMD6, CND6
25a 80,000 480 2 or 3 600–4000
SCLD6-B, SCMD6-B, SCND6-B, CPD6
60,000 600

Applicable Standards UL486B — Wire Connectors and UL50 — Cabinets and Boxes
UL489 — Molded Case Circuit Breakers Solderless Lugs for use with UL869 — Service Equipment
and Circuit Breaker Enclosures. aluminum wire
NEMA AB-1 — Molded Case Circuit
UL486A — Wire Connectors and UL943 — Ground Fault Interrupters (for Breakers and Molded Case Switches
Solderless Lugs for use with copper wire personnel protectors)
CSA–C22.2 No. 5, C22.2 No. 14
UL1087 — Molded Case Switches

Note: 75°C wire for circuit breakers having a rated ampacity of a Interrupting ratings are not limited to the values or groups of
(A) Molded case circuit breakers are designed and tested 100 amperes or less. Circuit breakers having a rated ampacity values listed. However, the values listed are minimum values
in accordance to applicable portions of UL489 and meet greater than 100 amperes shall only be cabled with 75°C for the class specified.
application requirements of the National Electric Code. cable unless otherwise indicated on the circuit breaker b Single-unit or duplex construction must be specified.
Unless marked otherwise, circuit breakers are 80% duty rated. label. Exceptions to this rule are outlined in the article c Use minimum frame size for ampere rating.
(B) Molded case circuit breakers are to be connected with 60 or 110-14 C(1)(2) of the 2005 National Electric Code.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-5


Revised on 11/30/19

Molded Case Circuit Breakers


Reference Guide Selection/Application

Thermal-Magnetic Trip Breakers Plug-In Breakers Panelboard Breakers

QP, QPH, HQP,


a
QT QPP QPPHa HQPPa HQPPHa QPJg BLh BLH HBL
Page 7-21 7-22, 7-24 7-22, 7-24 7-20, 7-24 7-20, 7-24 7-24 7-29 7-29 7-29
Poles 1, 2 1, 2, 3 1, 2, 3 1, 2, 3e 2 2, 3 1,2,3 1,2,3 1,2,3
Amperes 15-50 10-125 10-125 10-125e 100-225 150-200 10-125 15-125 15-100
1 Pole 120/240 120/240 120/240
120/240 120/240 120/240 120/240 120/240 120/240
Volts (50/60 Hz) 2 Pole 120/240 120/240 120/240
3 Pole — 240 240 240 240 240 240 240 240
120V 10,000 10,000 22,000 65,000 — — 10,000 22,000 65,000
240V 10,000 10,000 22,000 65,000 100,000 10,000 10,000 22,000 65,000
277V — — — — — — — — —
347V — — — — — — — — —
UL
480/277V — — — — — — — — —
480V — — — — — — — — —
AC 600/347V — — — — — — — — —
Ratings

Interrupt 600V — — — — — — — — —
Rating
2-Pole
lCU — — — — — — — — —
Symmetrical
220/ lCS — — — — — — — — —
RMS
240V
2, 3-Pole
lCU — — — — — — — — —
Amperes
lCS — — — — — — — — —
IEC 2-Pole
lCU — — — — — — — — —
947-2 380/ lCS — — — — — — — — —
50/ 415V
2, 3-Pole
lCU — — — — — — — — —
60Hz
i
lCS — — — — — — — — —
2-Pole
lCU — — — — — — — — —
lCS — — — — — — — — —
500V
2, 3-Pole
lCU — — — — — — — — —
lCS — — — — — — — — —
2-Pole — — — — — — — — —
DC 125/250 V DC Interrupting Rating
3-Pole — — — — — — — — —
10-50A — 2.87 2.87 — — — 3.56 3.56 3.75
Height 10-60A 3.12 — — — — — — — —

Dimensions 55-125A — 3.12 3.12 3.12 3.12 3g 3.75 3.75 3.75


in Inches
1-Pole 1.00 1.00 1.00 1.00 — — 1.00 1.00 1.00
g
Width 2-Pole 2.00 2.00 2.00a 2.00 4.00 2.00 2.00 2.00
3-Pole 3.00 3.00 3.00 3.00 — 3.00g 3.00 3.00 3.00
Depth 2.06 2.37 2.37 2.37 2.37 2.34 2.37 2.37 2.37
Thermal and Fixed magnetic Trip u u u u u u u u u
Thermal and Adjustable Magnetic trip — — — — — — — — —
Overcurrent
Adjustable Magnetic trip only — — — — — — — — —
Devices
Motor Circuit Protector — — — — — — — — —
7

Molded Case Switch — ud — — — — — — —


Undervoltage Trip — — — — — — — — —
Shunt Trip — —
MOLDED CASE
CIRCUIT BREAKERS

ud ud uf uf u u u
Accessories & Auxilary Switch — — — — uf — u u u
Modifications Alarm Switch — — — — — — — — —
Mechanical Interlock — — — — — — — — —
Fungus Proofing (ref. page 7-146) — — — — — — u u u
Type 1 - Indoor Surface u u u u u —
Individual
Type 1 - Indoor, Flush — u u u u —
Enclosures
Type 3R - Outdoor-Rainproof — u u u u —

Q3100 B120 B220H B320HH

For inches / millimeters conversion, see Application Data section.


For Plug-in Breakers, see Load Centers & Circuit Breakers section.
aTypes QPP, QPPH, HQPP and HQPPH are special 2-pole dNot applicable to types QPP and QPPH. g Fits
only Siemens EQIII load centers. Breaker is 2 or 3
configurations for metering equipment. Amperage range = e Singlepole circuit breakers available in ratings 15-70A only, poles wide.
125–225A, width = 4 in. 125A available as a 2-pole only. h 10A, 1-pole & 2-pole 120/240V AC only.
bSingle pole breakers available in ratings 10–70A only. f Not applicable to type HQPP and HQPPH. i Applicable for 15-30A breakers only.
c125A, 2-pole 120/240V AC only.

7-6 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 11/30/19

Molded Case Circuit Breakers


Reference Guide Selection/Application

Thermal-Magnetic Trip Breakers Panelboard Breakers

BQD, NGB HGB LGB 3VA41 3VA41 3VA41


a
BQD6 NGB2b HGB2b LGB2b SEAB MEAB HEAB
Page 7-32 7-33 7-33 7-33 7-36, 7-37 7-36, 7-37 7-36, 7-37
Poles 1,2,3 1,2,3 1,2,3 1,2,3 1, 2, 3 1, 2, 3 1, 2, 3
Amperes 15-100 15-125 15-125 15-125 15-125 15-125 15-125
1 Pole 277 347 347 347 347 347 347
Volts (50/60 Hz) 2 Pole 480/277 600/347 600/347 600/347 600/347 600/347 600/347
3 Pole 480/277 600/347 600/347 600/347 600/347 600/347 600/347
120V 65,000 — — — — — —
240V 65,000 100,000 100,000 100,000 65,000 85,000 150,000
277V 14,000 25,000 35,000 65,000 25,000 35,000 65,000
14,000b 14,000b
347V 10,000 14,000 14,000 18,000 25,000
22,000 65,000
UL 480/277V 14,000 25,000 35,000 65,000 25,000 35,000 65,000
— — — 25,000 35,000 65,000
480V — 25,000
b
35,000b 65,000b
AC
Ratings

14,000 14,000b
Interrupt 600/347V 10,000 14,000 14,000 18,000 25,000
22,000b 65,000
Rating 600V — — — — — — —
Symmetrical
RMS 2-Pole
lCU 18,000 — — — — — —
Amperes
220/ lCS 9,000 — — — — — —
240V l
2, 3-Pole CU
65,000 — — — — — —
lCS 33,000 — — — — — —
IEC
2-Pole
lCU — — — — — — —
947-2 380/ lCS — — — — — — —
50/ 415V l
2, 3-Pole CU
18,000 — — — — — —
60Hz lCS 9,000 — — — — — —
2-Pole
lCU — — — — — — —
500V
lCS — — — — — — —
l
2, 3-Pole CU
— — — — — — —
lCS — — — — — — —
125/250 V DC Interrupting 2-Pole 14,000 14,000 14,000 14,000 — — —
DC
Rating 3-Pole — — — — — — —
5.00b 5.00b 5.00b
10-50A 4.50 — — —
5.40 5.40 5.40
Height 10-60A — — — — — — —
5.00b 5.00b 5.00b
Dimensions 55-125A 4.50 5.1 5.1 5.1
5.40 5.40 5.40
in Inches
1-Pole 1.00 1.00 1.00 1.00 1.0 1.0 1.0
Width 2-Pole 2.00 2.00 2.00 2.00 2.0 2.0 2.0
3-Pole 3.00 3.00 3.00 3.00 3.0 3.0 3.0
Depth 2.69 2.71 2.71 2.71 3.6 3.6 3.6
Thermal and Fixed magnetic Trip u u u u u u u
Thermal and Adjustable Magnetic trip — — — — — — —
Overcurrent

7
Adjustable Magnetic trip only — — — — — — —
Devices
Motor Circuit Protector — — — — — — —
Molded Case Switch — — — — — — —

CIRCUIT BREAKERS
MOLDED CASE
Undervoltage Trip — — — — √ √ √
Shunt Trip u u u u √ √ √
Accessories & Auxilary Switch u u u u √ √ √
Modifications Alarm Switch u u u u √ √ √
Mechanical Interlock — — — — √ √ √
Fungus Proofing (ref. page 7-146) u u u u
Type 1 - Indoor Surface
Individual
Type 1 - Indoor, Flush
Enclosures
Type 3R - Outdoor-Rainproof

NGB1B030B

For inches / millimeters conversion, see Application Data section.


For Plug-in Breakers, see Load Centers & Circuit Breakers section.

a BQD6CSA certified 10,000A @ 600Y/347V 15–70A only.


b When two numbers are shown for the xGB/xGB2 column,
the top rating is for xGB and the bottom rating for xGB2.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-7


Revised on 11/30/19

Molded Case Circuit Breakers


Reference Guide Selection/Application

Thermal-Magnetic Trip Breakers General Purpose Breakers

BQ BQH HBQ QR2 QRH2 HQR2 HQR2H


Page 7-38 7-38 7-38 7-40 7-40 7-40 7-40
Poles 1, 2, 3 1, 2, 3 1, 2, 3 2, 3 2, 3 2, 3 2, 3
1-Pole 15–70 15–70 15–50 — — — —
Amperes, Continuous 2-Pole 15–125 15–100 15–70 100–250 100–250 100–250 100–250
3-Pole 15–100 15–100 15–100 100–250 100–250 100–250 100–250
1-Pole 120/240 120/240 120/240 — — — —
Volts (50/60 Hertz) 2-Pole 240 240 240 240 240 240 240
3-Pole 240 240 240 240 240 240 240
120V 10,000 22,000 65,000 — — — —
Interrupt Rating Symmetrical RMS Amperes

240V 10,000 22,000 65,000 10,000 25,000 65,000 100,000


UL
480V — — — — — — —
600/347V — — — — — — —
AC Icu — — — — — — —
Ratings

1-Pole
220/ Ics — — — — — — —
240V Icu — — — — — — —
2,3-Pole
Ics — — — — — — —
Icu — — — — — — —
IEC 1-Pole
947-2 380/ Ics — — — — — — —
50/ 415V Icu — — — — — — —
60Hz 2,3-Pole
Ics — — — — — — —
Icu — — — — — — —
1-Pole
Ics — — — — — — —
500V
Icu — — — — — — —
2,3-Pole
Ics — — — — — — —
Volts — 2-Pole — — — — — — —
DC
Interrupting Rating — DC Amperes — — — — — — —
15–50A 3.75 3.75 4.00 — — — —
Height 55–125A 4.00 4.00 4.00 — — — —
60–225A — — — 7.00 7.00 7.00 7.00
Dimensions
1-Pole 1.00 1.00 1.00 — — — —
in inches
Width 2-Pole 2.00 2.00 2.00 3.00 3.00 3.00 3.00
3-Pole 3.00 3.00 3.00 4.50 4.50 4.50 4.50
Depth 2.37 2.37 2.37 2.53 2.53 2.53 2.53
Overcurrent Thermal and Fixed Magnetic Trip u u u u u u u
7

Devices Molded Case Switch u — — — — — u


Undervoltage Trip — — — — — — —
MOLDED CASE
CIRCUIT BREAKERS

Shunt Trip u u u u u u u
Accessories and Auxiliary Switch u u u u u u u
Modifications Alarm Switch — — — — — — —
Mechanical Interlock — — — u u u u
Fungus Proofing (ref. page 7-146) u u u u u u u
Type 1 — Indoor Surface u u u u u u u
Individual Type 1 — Indoor, Flush u u u u u u u
Enclosures Type 3R — Outdoor-Rainproof u u u u u u u
Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — — — — — —

BQ1B020 BQ1B020H HB1B020


For inches / millimeters conversion, see Application Data section.
 CQD breakers are rated 14,000 KAIC at 480/277V.  3-pole only.
 Type CQD6—CSA only. d Applicable for 15-30A breakers only.

7-8 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 11/30/19

Molded Case Circuit Breakers


Reference Guide Selection/Application

Thermal-Magnetic Trip Breakers General Purpose Breakers

CQD NGG HGG LGG


Page 7-42 7-43 7-43 7-43
Poles 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3
1-Pole 15–100 15–125 15–125 15–125
Amperes, Continuous 2-Pole 15–100 15–125 15–125 15–125
3-Pole 15–100 15-125 15–125 15–125
1-Pole 277 347 347 347
Volts (50/60 Hertz) 2-Pole 480/277 600/347 600/347 600/347
3-Pole 480/277 600/347 600/347 600/347
120V 65,000 65,000 65,000 65,000
Interrupt Rating Symmetrical RMS Amperes

240V 65,000 65,000 65,000 65,000


UL
480V 14,000 25,000 35,000 65,000
600/347V 10,000b 14,000 14,000 14,000
AC Icu 18,000d 25,000 — —
Ratings

1-Pole
220/ Ics 9,000d 12,500 — —
240V 2,3- Icu 65,000d 65,000 — —
Pole Ics 32,500d 32,500 — —
Icu — — — —
IEC 1-Pole
947-2 380/ Ics — — — —
50/ 415V 2,3- Icu 18,000d 25,000 — —
60Hz Pole Ics 9,000d 12,500 — —
Icu — — — —
1-Pole
Ics — — — —
500V
2,3- Icu — — — —
Pole Ics — — — —
Volts — 2-Pole 125/250 125/250 125/250 125/250
DC
Interrupting Rating — DC Amperes 14,000 14,000 14,000 14,000
15–50A 4.50 5.40 5.40 5.40
Height 55–125A 4.50 5.40 5.40 5.40
60–225A — — — —
Dimensions
1-Pole 1.00 1.00 1.00 1.00
in inches
Width 2-Pole 2.00 2.00 2.00 2.00
3-Pole 3.00 3.00 3.00 3.00
Depth 2.87 2.90 2.90 2.90
Overcurrent Thermal and Fixed Magnetic Trip u u u u

7
Devices Molded Case Switch — — — —
Undervoltage Trip — — — —

CIRCUIT BREAKERS
MOLDED CASE
Shunt Trip u u u u
Accessories and Auxiliary Switch u u u u
Modifications Alarm Switch u u u u
Mechanical Interlock — — — —
Fungus Proofing (ref. page 7-146) u u u u
Type 1 — Indoor Surface — u u u
Individual Type 1 — Indoor, Flush — u u u
Enclosures Type 3R — Outdoor-Rainproof — u u u
Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — u u

CQD120 LGG2B020L
For inches / millimeters conversion, see Application Data section.
 CQD breakers are rated 14,000 KAIC at 480/277V.  3-pole only.
 Type CQD6—CSA only. d Applicable for 15-30A breakers only.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-9


Revised on 01/31/20

Molded Case Circuit Breakers


3VA UL Breakers Reference Guide

Type 3VA51 3VA51 3VA52 3VA53 3VA54 3VA55


Page 7-46 7-46 7-54 7-62 7-67 ??
Number of Poles 1 2, 3, 4 2 in 3-pole, 3 2 in 3-pole, 3, 4 2 in 3-pole, 3, 4 3, 4
3VA5 molded case circuit breakers
Size 125 A 125 A 250 A 400 A 600 A 800 A
Rated current In A 15 … 125 15 … 125 100 … 250 200 … 400 400 … 600 600 … 800
Frequency Hz 0 … 400 0 … 400 0 … 400 0 … 400 0 … 400 0 … 400

Electrical characteristics according to IEC 60947-2


Rated operational voltage
V 415 690 690 690 600 600
Ue 50/60 Hz AC
Rated insulation voltage Ui V 500 800 800 800 600 600

Electrical characteristics according to IEC 60947-2


Rated operational voltage
V 415 690 690 690 690 690
Ue 50/60 Hz AC
Rated insulation voltage Ui V 500 800 800 800 800 800
Rated impulse withstand
kV 8 8 8 8 8 8
voltage Uimp

Short-circuit breaking capacity


according to UL 489 S M H S M H M H C M H C M H C M H C
UL Breaker Type SEAS MEAS HEAS SEAS MEAS HEAS MFSA HFSA CFSA MJAS HJAS CJAS MLAS HLAS CLAS MMAS HMAS CMAS
120 V AC / 50/60 Hz kA 65 85 150 — — — — — — — — — — — — — — —
240 V AC / 50/60 Hz kA — — — 65 85 100 85 100 200 85 100 200 85 100 200 85 100 200
277 V AC / 50/60 Hz kA 25 35 50 — — — — — — — — — — — — — — —
347 V AC / 50/60 Hz kA 14 18 18 — — — — — — — — — — — — — — —
480 Y/277 V AC / 50/60 Hz kA — — — 25 35 65 35 65 100 35 65 100 35 65 100 35 65 100
480 V AC / 50/60 Hz kA — — — 25 35 65 35 65 100 35 65 100 35 65 100 35 65 100
7

600 Y/347 V AC / 50/60 Hz kA — — — 14 18 25 18 25 35 18 25 35 18 25 35 18 25 50


600 V AC / 50/60 Hz kA — — — — — — — — — — — — 18 25 35 18 25 50
125 V DC kA 14 25 30 — — — — — — — — — — — — — — —
MOLDED CASE
CIRCUIT BREAKERS

250 V DC kA — — — 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100


500 V DC kA — — — 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100
600 V DC (3-pole only) kA — — — — — — 50 85 100 50 85 100 50 85 100 50 85 100
750 V DC (4-pole only) kA — — — — — — — — — 50 85 100 50 85 100 50 85 100
1000 V DC (4-pole only) kA — — — — — — — — — 6 6 10 6 6 10 18 25 50

Short-circuit breaking capacity


S M H S M H M H C M H C M H C M H C
according to IEC 60947-2
Rated ultimate short-circuit breaking capacity Icu
Rated service short-circuit breaking capacity Ics
rms value, according to IEC 60947-2
240 V AC / 50/60 Hz kA 25/25 36/36 55/55 55/55 85/85 150/150 85/85 100/100 200/200 85/85 100/100 200/200 85/85 100/100 200/200 85 100 200
415 V AC / 50/60 Hz kA 5/5 5/5 5/5 36/36 55/55 70/70 55/55 70/70 110/110 55/55 70/70 110/110 55/55 70/70 110/110 55 70 110
690 V AC / 50/60 Hz kA — — — 5/5 7/5 10/5 7/7 10/10 10/10 7/7 10/10 10/10 7/7 10/10 10/10 25 35 35
125 V DC kA 14 25 30 — — — — — — — — — — — — — — —
250 V DC kA — — — 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100
500 V DC kA — — — 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100
750 V DC (3-pole only) kA — — — — — — 50 85 100 50 85 100 50 85 100 50 85 100
— Not available

Applicable Standards:
n UL489 - Molded Case Circuit Breakers
n UL486B- Wire connectors and solderless lugs for n EN 60947-1 AMD 2 - Molded case circuit breakers
n UL486A - Wire connectors and solderless lugs for use with aluminum wire n EN 60947-2 AMD 2 2013
use with copper
n CSA-22.2 No. 5-13 - Molded Case Circuit Breakers, n EN 50581 2012 - RoHS compliant
Molded case switches and circuit breaker enclosures

7-10 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 01/31/20

Molded Case Circuit Breakers


3VA UL Breakers Reference Guide

3VA61 3VA62 3VA63 3VA64 3VA65 3VA66


7-50, 7-51 7-58, 7-59 7-64, 7-65 7-68, 7-69 ?? ??
3, 4 3, 4 3, 4 3, 4 3, 4 3, 4

150 A 250 A 400 A 600 A 800A 1000A


15 … 125 15 … 125 100 … 250 200 … 400 600-800 1000
0 … 400 0 … 400 0 … 400 0 … 400 50-60 50-60

415 690 690 690 600 600


500 800 800 800 — —

415 690 690 690 690 690


500 800 800 800 800 800

8 8 8 8 8 8

M H C L E M H C H E M H C L E M H C L E M H C M H C
MDAE HDAE CDAE LDAE EDAE MFAE HFAE CFAE MFAE EFAE MJAE HJAE CJAE LJAE EJAE MLAE HLAE CLAE LLAE ELAE MMAE HMAE CMAE MMNAE HMNAE CMNAE
-Y -Y -Y -Y -Y
— — — — — — — — — — — — — — — — — — — — — — — — — —
100 100 200 200 — 100 100 200 200 — 100 100 200 200 — 100 100 200 200 — 100 150 200 100 150 200
— — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — —
35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 35 65 100
35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 35 65 100

7
18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 25 35 50 25 35 50
18 22 35 50 100 — — — — 100 18 22 35 50 100 18 22 35 50 100 25 35 50 25 35 50
— — — — — — — — — — — — — — — — — — — — — — — — — —

CIRCUIT BREAKERS
MOLDED CASE
— — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — —

M H C L E M H C L E M H C L E M H C L E M H C M H C

— — — — — — — — — — — — — — — — — — — — 85 110 200 85 110 200


55/55 85/85 110/110 150/150 200 55/55 85/85 110/110 150/150 200 55/55 85/85 110/110 150/150 200 55/55 85/85 110/110 150/150 200 55 85 110 55 85 110
— — — — 3 — — — — 3 — — — — 3 — — — — 3 25 35 35 25 35 35
— — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — — — — — — — — — —

UL Type Structure Position 1 Position 2 Position 3 Position 4


KAIC @ 480V Frame Family Trip System / Special Application
S = 25=low S = Standard TMTU or MCS (Molded Case Switch)
E = 125A max E = High End ETU
M= 35=med low
D = 150A max C = High Power ETU
H = 65=med
F = 250A max A = 3VA B = Bolt-On TMTU
C = 100=med high M= TMTU 50°C/NAVAL (UL 489 SB)
J = 400A max
L = 150=high P = TMTU MCP (Motor Circuit Protector)
L = 600A max
E = 200=extra high R = ETU MCP (Motor Circuit Protector)

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-11


Revised on 10/31/18

Molded Case Circuit Breakers


Reference Guide Selection/Application

Thermal-Magnetic Trip Breakers General Purpose Breakers


FD6A, HFD6, HHFD6,
ED2 ED4 ED6 HED4 HHED6 CED6 FXD6A HFXD6 HHFXD6 CFD6
Page 7-101 7-101 7-101 7-102 7-102 7-102 7-104 7-105 7-105 7-105
Poles 1, 2, 3 1, 2, 3 1d, 2, 3 1, 2, 3 3 2, 3 2, 3 2, 3 2, 3 3
Amperes, Continuous 15–100 15–125 15–125 15–125 15–50 15–125 70­–250 70-250 70-250 70–250
1-Pole 120 277 347 277 — — — — — —
Volts 50/60HZ 2-Pole 240 480 600 480 600 600 600 600 600 600
3-Pole 240 480 600 480 600 600 600 600 600 600
120V 10,000 — — 100,000 — — — — — —
240V 10,000 65,000 65,000 100,000 e 100,000 200,000 65,000 100,000 200,000 200,000
Symmetrical RMS Amperes

277V — 22,000 a — 65,000 b — — — — — —


UL
AC 347V — — 30,000 — — — — — — —
Ratings

480V — 18,000 25,000 142,000 65,000 200,000 35,000 65,000 100,000 200,000
600V — — 18,000 — 18,000 100,000 22,000 25,000 25,000 100,000
Interrupt Rating

Icu — 65,000h — — — 65,000 100,000 — —


220/240V
Ics — — 17,000h — — — 33,000 50,000 — —
IEC
947-2 Icu — 35,000h — — — 35,000 65,000 — —
380/415V
50/ Ics — — 9,000h — — — 18,000 33,000 — —
60HZ
Icu — — 18,000h — — — — — — —
500V
Ics — — 5,000h — — — — — — —
2-Pole, 250V DC Interrupting Ratings 5,000 30,000 30,000 30,000 — 30,000 30,000 30,000 — 50,000
DC
3-Pole, 500V DC Interrupting Ratingsc — — 18,000 — — 50,000 18,000 25,000 — 50,000
Height 6.34 6.34 6.34 6.34 6.58 9.26 9.50 9.50 14.12 14.12
1-Pole 1.00 1.00 1.00 1.00 — — — — — —
Dimensions 2-Pole 2.00 2.00 2.00 2.00 2.00 2.00 4.50 4.50 4.50 4.50
Width
in inches 3-Pole 3.00 3.00 3.00 3.00 3.00 3.00 4.50 4.50 4.50 4.50
4-Pole — — — — — — — — — —
Depth 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00
Thermal and Fixed Magnetic Trip u u u u u u — — — —
Thermal and Adjustable Magnetic Trip — — — — — — u u u u
Overcurrent
Adjustable Magnetic Trip only — — u — — u u — — u
Devices
Motor Circuit Protector u — — u
Molded Case Switch u u u — — u u — — u
Undervoltage Trip u u u u u u u u u u
Shunt Trip u u u u u u u u u u
Auxiliary Switch u u u u u u u u u u
7

Accessories Alarm Switch u u u u u u u u u u


and Mechanical Interlock — — — — — — u u u u
Modifications Rear Connection Studs
MOLDED CASE
CIRCUIT BREAKERS

u u u u u u u u u u
Electric Motor Operator u u u u u u u u u u
Plug-In Mounting Assembly (3 Pole Only) u u u u u u u u u u
Fungus Proofing (ref. page 7-146) u u u u u u u u u u
Type 1 — Indoor Surface u u u u u u u u u u
Type 1 — Indoor, Flush u u u u u u — u — u
Type 3R — Outdoor-Rainproof u u u u u u u u u u
Individual
Type 7 — Flammable Gas Atmosphere u u u u u — u u u —
Enclosures
Type 9 — Combustion Dusttight u u u u u — u u u —
Type 5, 12 — Lint, Fine Dust, Oils, Coolants u u u u u u u u u u
Type 12K — Semi-Dusttight u u u u u u u u u u

For inches / millimeters conversion, see Application Data section.


a 1-pole only.
b 35-100A: 25,000 AIR at 277V AC/15-30A:
65,000 AIR at 277V AC.
c For DC UPS system application.
d Single pole ED6 (15–30A) 30kA, (35–100A) 18 kA. CSA Only.
e Single pole HED4, 15-30A: 65,000 AIR at 240V AC; single
pole HED4, 35-100A: 25,000 AIR at 240V AC.
f HGG and LGG breakers are rated at 600/347V.
g ED6, 2-pole available 20-30 amps only.
h Rating applicable only to 3-pole breakers
ED62B020 HED41B040 HHED63B020

7-12 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 10/31/18

Molded Case Circuit Breakers


Reference Guide Selection/Application

Thermal-Magnetic Trip Breakers General Purpose Breakers


JD6-A, HJD6-A, HHJD6-A, LD6, HLD6, HHLD6,
JXD2-A JXD6-A HJXD6-A HHJXD6-A CJD6-A LXD6 HLXD6 HHLXD6 CLD6-A
Page 7-107 7-107 7-108 7-108 7-108 7-111 7-112 7-112 7-112
Poles 2, 3 2, 3 2, 3 2, 3 3 2, 3 2, 3 2, 3 3
Amperes, Continuous 200-400 200-400 200-400 200-400 200-400 250-600 250-600 250-600 450-600
2-Pole
Volts 50/60HZ 240 600 600 600 600 600 600 600 600
3-Pole
240V 65,000 65,000 100,000 200,000 200,000 65,000 100,000 200,000 200,000
Symmetrical RMS Amperes

UL 480V — 35,000 65,000 100,000 150,000 35,000 65,000 100,000 150,000


AC 600V — 25,000 35,000 50,000 100,000 25,000 35,000 50, 000 100,000
Ratings

220/ Icu — 65,000 100,000 — — 65,000 100,000 — —


240V Ics — 33,000 50,000 — — 33,000 50,000 — —
Interrupt Rating

IEC 947-2 380/ Icu — 40,000 65,000 — — 40,000 65,000 — —


50/60HZa 415V Ics — 20,000 33,000 — — 20,000 33,000 — —
Icu — — — — — — — — —
500V
Ics — — — — — — — — —
2-Pole 250V DC Interrupting Ratings 30,000 30,000 30,000 — — 30,000 30,000 — —
DC
3-Pole, 500V DC Interrupting Ratingsb — 25,000 35,000 — 50,000 35,000 — — 50, 000
Height 11.00 11.00 11.00 11.00 17.86 11.00 11.00 11.00 17.86
Dimensions in
Width 2, 3-Pole 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50
inches
Depth 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00
Thermal and Fixed Magnetic Trip — — — — — — — — —
Thermal and Adjustable Magnetic Trip u u u u u u u u u
Overcurrent
Devices Adjustable Magnetic Trip Only
— u — — u u — — u
Motor Circuit Protector
Molded Case Switch u u u — u u u — u
Undervoltage Trip u u u u u u u u u
Shunt Trip u u u u u u u u u
Auxiliary Switch u u u u u u u u u
Alarm Switch u u u u u u u u u
Accessories &
Mechanical Interlock u u u u u u u u u
Modifications
Rear Connection Studs u u u u u u u u u
Electric Motor Operator u u u u u u u u u
Plug-In Mounting Assembly u u u u u u u u u
Fungus Proofing (ref. page 7-146) — u u u u u u u u
Type 1 — Indoor Surface u u u u u u u u u

7
Type 1 — Indoor, Flush — — — — — — — — —
Type 3R — Outdoor-Rainproof u u u u u u u u u
Individual

CIRCUIT BREAKERS
MOLDED CASE
Enclosures Type 7 — Flammable Gas Atmosphere u u u u — u u u —
Type 9 — Combustion Dusttight u u u u — u u u —
Type 5, 12 — Lint, Fine Dust, Oils, Coolants u u u u u u u u u
Type 12K — Semi-Dusttight u u u u u u u u u

For inches / millimeters conversion, see Application Data section.


a Only
applicable to non-interchangeable trip unit types:
JXD6-A, HJXD6-A, LXD6 and HLXD6
b For
DC UPS application.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-13


Revised on 10/31/18

Molded Case Circuit Breakers


Reference Guide Selection/Application

Thermal-Magnetic Trip Breakers General Purpose Breakers


LMD6, HLMD6, MD6, HMD6, ND6, HND6, PD6,b HPD6,b
LMXD6 HLMXD6 MXD6 HMXD6 CMD6 NXD6 HNXD6 CND6 PXD6 b HPXD6b CPD6b
Page 7-115 7-116 7-118 7-119 7-119 7-122 7-123 7-123 7-126 7-126 7-126
Poles 2, 3 2, 3 2, 3 2, 3 3 2, 3 2, 3 3 3 3 3
500- 500- 500- 500- 400- 800- 800- 800- 1200- 1200- 1200-
Amperes, Continuous
800 800 800 800 800 1200 1200 1200 1600 1600 1600
2-Pole
Volts 50/60 HZ 600 600 600 600 600 600 600 600 600 600 600
3-Pole
240V 65,000 100,000 65,000 100,000 200,000 65,000 100,000 200,000 65,000 100,000 200,000
Symmetrical RMS Amperes

UL 480V 50,000 65,000 50,000 65,000 100,0001 50,000 65,000 100,000 50,000 65,000 100,000
AC 600V 25,000 50,000 25,000 50,000 65,0001 25,000 50,000 65,000 25,000 50,000 65,000
Ratings

220/ Icu — — 65,000 100,000 — 65,000 100,000 — — — —


240V Ics — — 33,000 50,000 — 33,0001 50,000 — — — —
Interrupt Rating

IEC 947-2 380/ Icu — — 40,000 65,000 — 40,0001 65,000 — — — —


50/60HZc 415V Ics — — 20,000 33,000 — 20,00011 33,000 — — — —
Icu — — — — —1 — — — — — —
500V
Ics — — — — — —1 — — — — —
2-Pole 250V DC Interrupting Ratings 30,000 30,000 30,000 30,000 30,0001 30,0001 30,000 30,000 30,000 30,000 30,000
DC
3-Pole, 500V DC Interrupting Ratingsa 25,000 50,000 25,000 50,000 50,000 25,00011 50,000 50,000 25,000 50,000 50,000
Dimensions Circuit breakers require Height 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.0 16.00 16.00
in inches Connect-all mounting Width 7.50 7.50 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00
block. Dims shown are
for circuit breaker only. Depth 4.59 4.59 6.19 6.19 6.19 6.191 6.19 6.19 6.19 6.19 6.19
Overcurrent Thermal and Adjustable Magnetic Trip u u u u u u u u u u u
Devices Adjustable Magnetic Trip Only —
u — u — u — — — — —
Motor Circuit Protector
Molded Case Switch u — u u — —
Accessories Undervoltage Trip u — u — u u u u u u u
and Shunt Trip u u u u u u u u u u u
Modifications
Auxiliary Switch u u u u u u u u u u u
Alarm Switch u u u u u u u u u u u
Mechanical Interlock u u u u u u u u u u u
Rear Connections Studs u u u u u u u u — — —
Electric Motor Operator u u u u u u u u u u u
Plug-in Mounting Assembly u u u u u u u u — — —
Fungus Proofing (ref. page 7-146) — — u u u u u u u u u
Mounting Block (required) — — — — — — — — u u u
7

Individual Type 1 — Indoor Surface u u u u u u u u u u u


Enclosures Type 1 — Indoor, Flush — — — — — — — — — — —
MOLDED CASE
CIRCUIT BREAKERS

Type 3R — Outdoor-Rainproof u u u u u u u u — — —
Type 7 — Flammable Gas Atmosphere — — — — — — — — — — —
Type 9 — Combustion Dusttight — — — — — — — — — — —
Type 5, 12 — Lint, Fine Dust, Oils,
— — — — — — — — — — —
Coolants
Type 12K — Semi-Dusttight u u u u u u u u — — —

For inches / millimeters conversion, see Application Data section.

a For DC UPS application. b Requires Connect-all mounting assembly. Dimensions c Only applicable to non-interchangeable trip unit types:
shown are for circuit breaker only. NXD6, HNXD6, MXD6 and HMXD6

7-14 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/18

Molded Case Circuit Breakers


Reference Guide Selection

General Purpose
Thermal-Magnetic Trip Breakers
Breakers Solid State Trip Circuit Breakers
& Electronic Trip Breakers
RD6,a HRD6,a
RXD6 a HRXD6a SJD6 SHJD6 SCJD6 SLD6 SHLD6 SCLD6
Page 7-129 7-129 7-109 7-109 7-109 7-113 7-113 7-113
Poles 3 3 3 3 3 3 3 3
Amperes, Continuous 1600-2000 1600-2000 200-400 200-400 200-400 300-600 300-600 300-600
Volts 50/60 HZ 3-Pole 600 600 600 600 600 600 600 600
240V 65,000 100,000 65,000 100,000 200,000 65,000 100,000 200,000
UL 480V 50,000 65,000 35,000 65,000 150,000 35,000 65,000 150,000
600V 25,000 50,000 25,000 35,000 100,000 25,000 35,000 100,000
AC
Ratings Interrupt Rating Icu — — — — — — — —
Symmetrical RMS 220/240V
Ics — — — — — — — —
Amperes
IEC60947-2 Icu — — — — — — — —
380/415V
50/60HZ Ics — — — — — — — —
Icu — — — — — — — —
500V
Ics — — — — — — — —
2-Pole 250V DC Interrupting Ratings 30,000 30,000 — — — — — —
DC
3-Pole, 500V DC Interrupting Ratingsa 25,000 50,000 — — — — — —
Height 16.00 16.00 11.00 11.00 17.86 11.0 11.00 17.86
Dimensions in Width 3-Pole 9.00 9.00 7.50 7.50 7.50 7.50 7.50 7.50
inches
Depth 6.19 6.19 4.00 4.00 4.00 4.00 4.00 4.00
Solid State Trip — — u u u u u u
Optional DAS / Maintenance Mode — — u u u u u u
Overcurrent Thermal and Adjustable Magnetic Trip u u — — — — — —
Devices Adjustable Magnetic Trip Only — — — — — — — —
Motor Circuit Protector
Molded Case Switch u — — — — — — —
Undervoltage Trip u u u u u u u u
Shunt Trip u u u u u u u u
Auxiliary Switch u u u u u u u u
Accessories & Alarm Switch u u u u u u u u
Modifications Mechanical Interlock u u u u u u u u
Rear Connections Studs — — u u u u u u
Electric Motor Operator u u u u u u u u
Plug-In Mounting Assembly — — u u u u u u
Fungus Proofing (ref. page 7-146) u u u u u u u u

7
Mounting Block (required) u u — — — — — —
Type 1 — Indoor Surface u u u u u u u u

CIRCUIT BREAKERS
MOLDED CASE
Type 1 — Indoor, Flush — — — — — — — —
Type 3R — Outdoor-Rainproof — — u u — u u —
Individual Type 7 — Flammable Gas Atmosphere — — u u — u u —
Enclosures
Type 9 — Combustion Dusttight — — u u — u u —
Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — u u u u u u
Type 12K — Semi-Dusttight — — u u u u u u

For inches / millimeters conversion, see Application Data section.


a Requires
Connect-all mounting assembly. Dimensions
shown are for circuit breaker only.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-15


Revised on 05/31/18

Molded Case Circuit Breakers


Reference Guide Selection

Electronic Trip Breakers


Solid State Trip Circuit Breakers
SMD6 SHMD6 SCMD6 SND6 SHND6 SCND6 SPD6 a SHPD6 a
Page 7-120 7-120 7-120 7-124 7-124 7-124 7-127 7-127
Poles 3 3 3 3 3 3 3 3
Amperes, Continuous 600- 600- 600- 800- 800- 800- 1200- 1200-
- 800 800 800 1200 1200 1200 1600 1600
Volts 50/60HZ 3-Pole 600 600 600 600 600 600 600 600
240V 65,000 100,000 200,000 65,000 100,000 200,000 65,000 100,000
UL 480V 50,000 65,000 100,000 50,000 65,000 100,000 50,000 65,000
Ratings AC Interrupt
Rating 600V 25,000 50,000 65,000 25,000 50,000 65,000 25,000 50,000
Symmetrical Icu — — — — — — — —
RMS 380/415V
IEC60947-2 Ics — — — — — — — —
Amperes 50/60HZ
Icu — — — — — — — —
690V
Ics — — — — — — — —
Height 10.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00
Dimensions
in Width 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00
inches
Depth 6.19 6.19 6.19 6.19 6.19 6.19 6.19 6.19

Overcurrent Solid State Trip u u u u u u u u


Devices Optional DAS / Maintenance Mode u u u u u u u u
Undervoltage Trip u u u u u u u u
Shunt Trip u u u u u u u u
Auxiliary Switch u u u u u u u u
Alarm Switch u u u u u u u u
Accessories & Mechanical Interlock u u u u u u u u
Modifications
Rear Connection Studs u u u u u u — —
Electric Motor Operator u u u u u u u u
Plug-In Mounting Assembly u u u u u u — —
Fungus Proofing (ref. page 7-146) u u u u u u u u
Type 1 — Indoor Surface u u u u u u u u
Type 1 — Indoor, Flush — — — — — — — —
Type 3R — Outdoor-Rainproof u u u u u u — —
Individual Type 7 — Flammable Gas Atmosphere — — — — — — — —
Enclosures
Type 9 — Combustion Dusttight — — — — — — — —
Type 5, 12 — Lint, Fine Dust, Oils, Coolants u u u u u u — —
Type 12K — Semi-Dusttight — —
7

u u u u u u
MOLDED CASE
CIRCUIT BREAKERS

For inches / millimeters conversion, see Application Data section.


a Requires
connect-all mounting block assembly. Dimensions
shown are for circuit breaker.

7-16 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 10/31/18

Molded Case Circuit Breakers


Reference Guide Selection/Application

Page 7-165 7-169 7-173


Breaker Frame Family DG FG JG
Continuous Amps 30–150A 40–250A 70–400A
Poles 2, 3 2, 3 2, 3
Max. Volts AC 600Y/347V 600Y/347V 600V
Breaker Type NDGA HDGA LDGA NFGA HFGA LFGA NJGA HJGA LJGA
Interrupting Class N H L N H L N H L
240Vac 65 100 200 65 100 200 65 100 200
Interrupting UL 480Vac 35 65 100 35 65 100 35 65 100
Rating RMS 600Vac 18 18 18 18 18 18 25 25 25
Symmetrical
Amperes 220/240Vac 65/65 100/75 200/150 65/65 100/75 200/150 65/65 100/75 200/150
Ratings
AC 50/60Hz lCU/lCS 380/415Vac 40/40 70/70 100/75 40/40 70/70 100/75 45/45 70/70 100/75
690Vac 12/6 12/6 12/6 12/6 12/6 12/6 12/6 15/8 15/8
DC 250Vdc (2-Pole) 30 30 30 30 30 30 30 30 30
Interrupting 500Vdc (3-Pole) 18 18 18 18 18 30 25 35 35
b
Ratings (UL) 600Vdc (3-Pole) — — — — 42 — — 65 —
1-Pole — —
Dimensions 2-Pole 6.9H x 4.1W x 3.4D 11H x 5.5W x 4.2D
in Inches 3-Pole 6.9H x 4.1W x 3.4D 11H x 5.5W x 4.2D
4-Pole — —
Thermal-Magnetic u u u
Electronic u u u
Trip Unit Electronic with LCD u u u
Information Interchangeable Trip Unit — — u
Reverse Feed (w/Non-Interchangeable Trip) u u u
Communications Capability  u u u
Molded Case Switch u u u
Specific Motor Circuit Protector
Application
u u u
Breakers 100% Rated u u
50°C Calibrated
Auxiliary Switch u u u
Alarm Switch u u u
Shunt Trip u u u
Undervoltage Release u u u
Accessories & Mechanical Interlocks u u u
Modifications Electric Motor or Stored Energy Operator u u u

7
Rear Connecting Studs u u u
Plug-In Mounting Assy. w/Trip Interlock u u u
Draw-Out Assembly

CIRCUIT BREAKERS
MOLDED CASE
u u u
Handle Mechanism Options u u u
NEMA 1 – Indoor, Surface Mount u u
NEMA 1 – Indoor, Flush Mount u u
NEMA 3R – Outdoor, Rain Proof u u
Enclosures
NEMA 4, 4X – Stainless Steel u u
NEMA 7, 9 – Hazardous Locations
NEMA 12 – Dust u u
Terminal Shields u u u
Distribution Lugs u u u
Ground Sensor (Neutral Transformer) u u u

a 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems.


b DC Interrupting Ratings are not applicable to electronic circuit breakers.
 Communications available via a COMPRO or COMMOD modules using Profibus or Modbus protocols.
 Consult Siemens for availability.
 “Non-metallic” NEMA 4X enclosure for NGG breakers.
 Special version, see page 7-194.
GG are not VL family breakers and do not share common VL accessories.
 304 and 316 Stainless Steel

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-17


Molded Case Circuit Breakers
Reference Guide Selection/Application

Page 7-177 7-181 7-185 7-189


Breaker Frame Family LG MG NG PG
Continuous Amps 150–600A 200–800A 300–1200A 400–1600A
Poles 2, 3 2, 3 2, 3 3
Max. Volts AC 600V 600V 600V 600V
Breaker Type NLGB HLGB LLGB NMG HMG LMG NNG HNG LNG NPG HPG LPG
Interrupting Class N H L N H L N H L N H L
240Vac 65 100 200 65 100 200 65 100 200 65 100 200
Interrupting UL 480Vac 35 65 100 35 65 100 35 65 100 35 65 100
Rating RMS 600Vac 18 18 18 25 35 65 25 35 65 25 35 65
Symmetrical
Amperes 220/240Vac 65/65 100/75 200/150 65/35 100/50 200/150 65/65 100/75 200/100 65/35 100/50 200/100
Ratings lCU/
AC 50/60Hz 380/415Vac 45/45 70/70 100/75 50/50 70/70 100/75 50/25 70/35 100/50 50/25 70/35 100/50
lCS
690Vac 12/6 15/8 15/8 20/10 30/15 35/17 20/10 30/15 35/17 20/10 30/15 35/15
250Vdc (2-Pole) 30 30 30 22 25 42 22 25 42 22 25 42
DC
Interrupting 500Vdc (3-Pole) 25 35 35 35 50 65 35 50 65 35 50 65
Ratings (UL) c 600Vdc (3-Pole) — 65 — — 65 — — 65 — — 65 —
Dimensions 2-Pole 11H x 5.5W x 4.2D 16H x 7.5W x 4.7D 16H x 9W x 6.2D —
in Inches 3-Pole 11H x 5.5W x 4.2D 16H x 7.5W x 4.7D 16H x 9W x 6.2D
Thermal-Magnetic u u u u
Electronic u u u u
Trip Unit Electronic with LCD u u u u
Information Interchangeable Trip Unit u u u u
Reverse Feed (w/Non-Interchangeable Trip) u u u u
Communications Capability a u u u u
Specific Molded Case Switch u u u u
Application Motor Circuit Protector u u u
Breakers 100% Rated u u u u
Auxiliary Switch u u u u
Alarm Switch u u u u
Shunt Trip u u u u
Undervoltage Release u u u u
Accessories Mechanical Interlocks u u u u
and
Modifications Electric Motor or Stored Energy Operator u u u u
7

Rear Connecting Studs u u u u


Plug-In Mounting Assy. w/Trip Interlock u
MOLDED CASE
CIRCUIT BREAKERS

Draw-Out Assembly u u
Handle Mechanism Options u u u u
Terminal Shields u u u u
Distribution Lugs
Ground Sensor (Neutral Transformer) u u u u
a Communications available via COMPRO or COMMOD modules using Profibus or Modbus protocol.
b 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems.
c DC Interrupting Ratings are not applicable to electronic circuit breakers.
 LG frame maximum 500A.
 Special version, see page 7-194.
 Special 600Vac 25kA version available, see page 7-178.

7-18 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 01/31/20

Circuit Breakers
Arc-Fault and Ground-Fault Breakers Selection/Wiring Diagrams

Arc-Fault Circuit Interrupters (AFCI)


AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that stan-
dard circuit breakers are not designed to detect. The device is intended to mitigate
the effects of arcing faults by functioning to de-energize the circuit when an arc-
fault is detected.
Combination Type AFCI
Detects all three possible types of arc faults: line-to-ground, line-to-neutral, and series.
Breaker Amp 10,000 A IR 22,000 A IR 65,000 A IR
Type Rating Catalog No. Catalog No. Catalog No.

QAF2/QAFH2/HQAF2 15 QA115AFC QA115AFCH  QA115AFCHHn  1-Pole Combination 2-Pole Combination


1-Pole 120V AC 20 QA120AFC QA120AFCH  QA120AFCHHn  Type AFCI Type AFCI
QAF/QAFH 15 Q215AFC Q215AFCHn  —
2-Pole 120/240V AC 20 Q220AFC Q220AFCHn  —

QAF2N 15 QA115AFCN — —
Plug-on Neutral/1-Pole 120V AC 20 QA120AFCN — —
QAF/QAFH 15 Q215AFCN — —
Plug-on Neutral/2-Pole 120/240V AC 20 Q220AFCN — —

Dual Function AFCI/GFCI


The Dual Function Circuit Breaker combines Combination Type AFCI and 5mA GFCI
protection in one device. The device includes the Self Test feature, making it the first in
class in electrical safety for homeowners.
QFGA2/QFGAH2/HQFGA2 15 Q115DF Q115DFHn  Q115DFHHn  1-Pole Dual
1-Pole 120V AC 20 Q120DF Q120DFH  Q120DFHHn  Function AFCI/GFC
15 Q115DFN — —
QFGA2N
Plug-on Neutral/1-Pole 120V AC 20 Q120DFN — —

Ground-Fault Circuit Interrupters (GFCI)


Provides Class A (5mA) ground fault protection. Intended for personnel protection.
Includes Self Test as an added safety feature.
Amp 10,000 A IR 22,000 A IR 65,000 A IR
Breaker Type Rating Catalog No. Catalog No. Catalog No.
15 QF115Aa QF115AHna QF115AHHna
QPF2/QPHF2/HQPF2

7
20 QF120Aa QF120AHna QF120AHHna
1-Pole 120V AC 1-Pole AFCI 1-Pole Dual Function
30 QF130Aa QF130AHna QF130AHHna
15 QF215A QF215AHn — Plug-on Neutral Plug-on Neutral

CIRCUIT BREAKERS
MOLDED CASE
20 QF220A QF220AHn —
QPF/QPHF 30 QF230A QF230AHn —
2-Pole 120/240V AC 40 QF240A QF240AHn —
50 QF250A QF250AHn —
60 QF260A QF260AHn —
15 QF115AN — —
QPF2N 20 QF120AN — —
Plug-on Neutral/1-Pole 120V AC
30 QF130AN — —

Ground Fault Equipment Protection (30mA)


Provides protection of equipment from damaging line-to-ground faults currents.
15 QE115 QE115Hn —
QE/QEH 20 QE120 QE120Hn — 2-Pole GFCI
1-Pole 120V AC 1-Pole GFCI
30 QE130 QE130Hn —
15 QE215 QE215Hn —
20 QE220 QE220Hn —
QE/QEH 30 QE230 QE230Hn —
2-Pole 120/240V AC 40 QE240 QE240Hn —
50 QE250 QE250Hn —
60 QE260 QE260Hn —

QAF2/QPF/QE/QPF2 Accessories
Description Catalog Number
Padlocking Device 1-Pole ECPLD1 n Built to order. Allow 8 -10 weeks for delivery.
a  L Listed as SWD (Switching Duty) Rated, suitable
U
Padlocking Device 2-Pole ECPLD2 for 120V AC Fluorescent Lighting.
Handle Block ECBX231M

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-19


Revised on 10/31/18

Circuit Breakers
Type QP with INSTA-WIRE Selection

Type QP Type QPH Type HQP


Continuous Current 10,000A IR 22,000A IR 65,000A IR
Rating @ 40° C Catalog Number Catalog Number Catalog Number

1-Pole Plug-In (120/240V AC)e


10 Q110 — —
15 Q115c Q115Hc Q115HHnc
20 Q120c Q120Hc Q120HHnc
25 Q125 Q125Hn Q125HHn
30 Q130 Q130H Q130HHn
35 Q135n Q135Hn Q135HHn
40 Q140 Q140H Q140HHn
45 Q145n Q145Hn Q145HHn
50 Q150 Q150H Q150HHn
60 Q160 Q160Hn Q160HHn
70 Q170 Q170Hn Q170HHn

2-Pole Plug-In (Common-Trip 120/240V AC)


10 Q210 — —
Q120
15 Q215 Q215H Q215HH
20 Q220 Q220H Q220HH
25 Q225 Q225Hn Q225HHn
30 Q230 Q230H Q230HH
35 Q235 Q235Hn Q235HHn
40 Q240 Q240H Q240HHn
45 Q245 Q245Hn Q245HHn
50 Q250 Q250H Q250HH
60 Q260 Q260H Q260HH
70 Q270 Q270H Q270HH
80 Q280 Q280Hn Q280HHn
90 Q290 Q290H Q290HHn
100 Q2100 Q2100H Q2100HH
110 Q2110 Q2110H Q2110HHn
125 Q2125 Q2125H Q2125HH

2-Pole Plug-In (Common-Trip 240V AC)


15 Q215R — — Q220
20 Q220R — —
30 Q230R — —
40 Q240R — —
7

50 Q250R — —

3-Pole Plug-In (Common-Trip 240V AC)


MOLDED CASE
CIRCUIT BREAKERS

15 Q315 Q315H Q315HHn


20 Q320 Q320H Q320HH
25 Q325 Q325Hn Q325HHn
30 Q330 Q330H Q330HH
35 Q335 Q335Hn Q335HHn
40 Q340 Q340H Q340HH
45 Q345 Q345Hn Q345HHn
50 Q350 Q350H Q350HH
60 Q360 Q360H Q360HH
70 Q370 Q370H Q370HHn
80 Q380 Q380H Q380HHn
90 Q390 Q390H Q390HHn
Q320
100 Q3100 Q3100H Q3100HH

QP / QPH / HQP Internal Accessories Modifications


Control Voltage AC Catalog Number Field/Factory Installed Description Catalog Number For external
120V Shunt Trip add suffix …00S01n Factory 400 Hz Calibration add suffix …Yh accessories, please
24V Shunt Trip add suffix …00S07n Factory Marine 50˚C Ambient refer to page 7-148
Calibration add suffix …M
120V Auxiliary Switch add suffix …01nb Factory
Fungus Proofing add suffix …F

n Built to order. Allow 2-3 weeks for delivery. c UL Listed for frequent switching applications (SWD). f Shipped 6 per sleeve.
a UL
120V AC Fluorescent Lighting. g Shipped 4 per sleeve.
Listed for use with 60/75° wire through 40 amps, d UL Listed for use on 3-phase grounded “B” systems ­­— h UL Listed 5 KA IR.
UL listed for use with 75° wire only for 50 amps 10,000 for this application. i Type
 QP1, UL listed for 16 AWG conductors and
and above, HACR rated. e Shipped 12 per sleeve. multiple wires.
b 1A and 1B contacts.

7-20 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category RESI
Circuit Breakers
Duplex, Triplex and Quadplex Plug-In Breakers Selection

Duplex Circuit Breakers


Ampere
Breaker Type Rating Catalog Number Catalog Number
QT 15–15 Q1515 Q1515NCa
1-Pole 15–20 Q1520 Q1520NCa
10K AIC 20–20 Q2020 Q2020NCa
120V AC 20–30 Q2030 —
30–15n Q3015 —
30–20 Q3020 —
30–30 Q3030 Q3030NCa
QT Duplex
SHIPPING: 12 per carton, (Wt. 4.8 lbs.)
These space saver duplex breakers combine two
independent 1/2" breaker poles in a common unit.
Triplex Circuit Breakers This unit plugs into one load center stab and
requires one panel space. HACR rated.
Ampere Rating
Breaker Common-Trip Catalog
Type Single Pole 2-Pole Number
QT 15 15 Q21515CT
2-Pole 15 20 Q21520CT
10K AIC 15 25 Q21525CTn
120/240V AC 15 30 Q21530CT
Inner Poles 15 35 Q21535CTn
Common Trip
15 40 Q21540CT
15 45 Q21545CTn
15 50 Q21550CT
20 20 Q22020CT
20 25 Q22025CTn QT Triplex
20 30 Q22030CT These space saver triplex breakers provide
20 35 Q22035CTn a 2-pole common trip breaker for 120/240V AC
20 40 Q22040CT circuits and two single poles for 120V AC circuits.
20 45 Q22045CTn Triplex require two panel spaces. HACR rated.
20 50 Q22050CT
30 30 Q23030CT
SHIPPING: 6 per carton, (Wt. 4.9 lbs.)

Quadplex Circuit Breakers


Ampere Rating
Breaker Common-Trip Common-Trip Catalog
Type 2-Pole Outside 2-Pole Inside Number

7
QT 15 15 Q21515CT2
2-Pole 15 30 Q21530CT2

CIRCUIT BREAKERS
MOLDED CASE
10K AIC 20 20 Q22020CT2
120/240V AC 20 50 Q22050CT2
Inner and 30 20 Q23020CT2 QT Quadplex
Outter 2 Poles
30 25 Q23025CT2 These space saver quadplex breakers provide
Common Trip
30 30 Q23030CT2 two sets of common trip, two-pole breakers for
30 50 Q23050CT2 120/240V AC circuits, and require two panel
40 20 Q24020CT2 spaces. HACR rated.
40 30 Q24030CT2
40 40 Q24040CT2
SHIPPING: 6 per carton, (Wt. 4.8 lbs.)

For external accessories,


please refer to page 7-148

For inches / millimeters conversion, see Application Data n Built to order. Allow 2–3 weeks for delivery. a  on-CTL. For replacement use only in panels manufac-
N
section. tured before 1968

Product Category RESI Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-21
Circuit Breakers
Special Application Breakers Selection

HID Lighting
For high-intensity discharge lamp loads having in-rush currents
above the instantaneous trip setting of a standard breaker.
Breaker Wiring Complete Breaker UL Unenclosed
Type Diagram Ampere Rating Catalog Number
QP 15 Q115HID a n
1-Pole Figure 1 20 Q120HID a
120V AC 30 Q130HID
QP 15 Q215HID
2-Pole Figure 2 20 Q220HID n
120/240V AC 30 Q230HID n

Molded Case Switch


For applications that do not require overcurrent protection.
Switching Neutral
QP
1-Pole Figure 1 100 Q1100S
120V AC
Figure 1 Figure 2
QP 30 Q230S
2-Pole 50 Q250S
Figure 2
120/240V AC 60 Q260S
125 Q2125S

No-Noise
For applications that require a reduction in the 60-cycle hum of
a standard breaker. Figure 3 Figure 4
QP 50 Q250NNn
2-Pole Figure 2
60 Q260NN
120/240V AC

Switching Neutrals
Used where all conductors are required to be disconnected.
Neutral pole of the circuit breaker does not connect to load Wiring Diagrams
center bus. One side is wired to neutral and the other side to
the device.
QG
7

2-Wire 15 QG215
Figure 3
Common Trip 20 QG220
120V AC
MOLDED CASE
CIRCUIT BREAKERS

QG
3-Wire Figure 4 20 QG320
Common Trip
120/240V AC

a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting.
n Built to order. Allow 2–3 weeks for delivery.
Note: All circuit breakers on this page are 10K AIC

7-22 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category RESI
Circuit Breakers
3/4 Inch Plug-In Breakers Selection

Features
b 3/4" format
b HACR Rated
b UL Classified for use in certain Square D
load centers
Type QD Circuit Breakers
The Type QD circuit breaker line is
available in 1-pole and 2-pole common
trip versions listed on this page.
The circuit breakers are UL Classified D120 D220
and UL Listed.
All QD breakers are supplied with load
side connectors suitable for 60/75°C 1-Pole 2-Pole
Continuous
wire and are calibrated for 40°C Current Rating 120V 120/240V Common Trip
maximum ambient applications. @ 40°C Catalog Number Catalog Number
15 D115 a D215
UL Classified
20 D120 a D220
Siemens Type QD circuit breakers are 30 D130 D230
UL Classified for use in specific Square 40 D140 D240
D load centers in place of Square D Type 50 D150 D250
QO® circuit breakers. A Panelboard 60 D160 D260
Compatibility List packaged with each
QD breaker shows which type QD Shipping Weights
circuit breakers are acceptable for
use in Square D load centers. Number of Number Per Shipping
The interrupting rating on these circuit Poles Carton Weight (lbs.)
breakers is 10,000A IR maximum and 1 16 3.8
2 8 4.2
they are not series rated with Square D
circuit breakers or equipment. This UL
Classification allows a Siemens Type QD Panelboard Compatibility List
circuit breaker to be used in place of a Listed Panelboards—Square D—Catalog Numbers
Square D Type QO circuit breaker in
those load centers that are specifically QO2L30F/S QO12M100/RB QO120-30M150/RB QO130-40M200
shown on the Panelboard Compatibility QO2-4L70F/S QO16-20M100/RB QO124L150G QO130M200/RB
list. For additional information, contact QO2-4L70TS QO16M100/RB QO124M150 QO130-40L200G/RB

7
QO2-4L70RB QO20M100/RB QO130L150G/RB QO140M200/RB
your local Siemens sales engineer.
QO6-12L100F/S QO112L125G/RB QO130M150/RB QO16L200/RB

CIRCUIT BREAKERS
MOLDED CASE
QO6-12L100DF/S QO112-24L125G/RB QO16L150/RB QO16M200/RB
QO6-12L100TF/S QO112-24L125GWGC QO16M150/RB QO18-16M200FTRB
QO6-12L100DTF/S QO116L125G QO16-30L150/RB QO20-40L200/RB
QO6-12L100RB QO116-24L125G/RB QO18-16M150FTRB QO20-40M200TF/S
QO8-16L100F/S QO12-24L125/RB QO20-30M150/RB QO20-40M200/RB
QO8-16L100DF/S QO120-24L125G QO20-30M150TF/S QO24L200/RB
QO8-16L100TF/S QO120-24L125GWGC QO20-30L150 QO24M200/RB
QO8-16L100DTF/S QO120L125G QO24L150/RB QO30L200/RB
QO8-16L100RB QO124L125G/RB QO24M150/RB QO30M200/RB
QO112M100/RB QO124M125/RB QO30L150/RB QO30-40L200/RB
QO116M100/RB QO16L125/RB QO30M150/RB QO30-40M200/RB
QO120M100/RB QO16-12M125FTRB QO8-16M200FT/RB QO40M200/RB
QO124M100 QO16-24L125/RB QO112L200G/RB QO140M225
QO12L100DF/S QO20L125/RB QO120-40M200/RB QO142L225G/RB
QO12L100RB QO20-24L125/RB QO120-40M200TC
QO12-20M100/RB QO24L125/RB QO124M200
QO12-20M100TF/S QO120-30L150G QO130L200G/RB

For inches / millimeters conversion, see Application Data a  L Listed for frequent switching applications (SWD).
U
section. 120V AC Fluorescent Lighting. One or two load
conductors.

Product Category RESI Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-23
Revised on 10/31/18

Circuit Breakers
Main and Branch Circuit Breakersa Selection

Breaker Ampere Catalog Catalog UL Interrupting


Type Rating Number Number Ratings (kA)
QN 150 QN2150 QN2150R b 10
2-Pole 175 QN2175n QN2175R b n 10
120/240V AC 200 QN2200 QN2200R b 10
QNH 150 QN2150H QN2150RH b 22
2-Pole 175 QN2175H n QN2175RH bn 22
120/240V AC 200 QN2200H QN2200RH b 22
HQN 150 HQN2150 HQN2150R b 65
2-Pole 175 HQN2175 n — 65
120/240V AC 200 HQN2200 HQN2200R b 65 QNRe QNe
Requires 4 panel spaces, 2 adjacent and 2 opposite. SHIPPING: 1 per carton (Wt. 3 lbs.)

Main Breaker Kits


For use in Ultimate Load Centersd For use in EQIII Load Centers
UL Ampere Catalog UL Ampere Catalog UL Interrupting
Type Rating Number Type Rating Number Ratings (kA)
EQ8681 100 MBK100A EQ9675 100 MBK100 22
EQ8682 125 MBK125A EQ9677 125 MBK125 22
EQ8693 150 MBK150A EQ9683 150 MBK150 22
— — — EQ9684 175 MBK175n 22
EQ8695 200 MBK200A EQ9685 200 MBK200 22
EQ8696 225 MBK225A EQ9686 225 MBK225 22
EQ9675

Breaker Ampere Catalog UL Interrupting


Type Rating Number Ratings (kA)
QPJ
c
125 QPJ3125 10
3-Pole 150 QPJ3150 10
240V AC 200 QPJ3200 10

Requires 6 spaces due to cross over design. Fits only EQIII 125-400A 3-phase
load centers
SHIPPING: 5 per carton (Wt. 17 lbs.)
MBK MBK
(100,125)A (150,200,225)A
UL Interrupting
Breaker Ampere Catalog Breaker Ratings (kA)
Type Rating Number Volts AC 120/240
125 Q2125B 10
QPP
7

150 Q2150B 10
2-Pole 175 Q2175Bn 10
120/240V AC 200 Q2200B 10
MOLDED CASE
CIRCUIT BREAKERS

225 Q2225B 10
125 Q2125BH 22
QPPH 150 Q2150BH 22
2-Pole 175 Q2175BHn 22
120/240V AC 200 Q2200BH 22
225 Q2225BHn 22 QPJ
HQPH 100 HQ2100H 100
2-Pole, 120/240V AC 125 HQ2125H 100
125
HQPP 150
2-Pole 175 Obsolete
120/240V AC 200
225
100
125
HQPPH 150
2-Pole Obsolete
175
120/240V AC
200
2-Pole QPP
225

For inches / millimeters conversion, see Application Data section. a All circuit breakers on this page are common trip. e  NR required for horizontal applications or vertical
Q
b Reverse handle. applications where the lugs are facing up. The QN
n Built to order. Allow 2–3 weeks for delivery. c CSA Listed. breaker is required for vertical applications where the
d MBK100A
 for use in 100 and 125A load centers. lugs are facing down as shown.
MBK125A for use in 125A load centers.
MBK150A for use in 150, 200 and 225A load centers.
MBK200A for use in 200 and 225A load centers.
MBK225A for use in 225A load centers.
MBK175A for use in 200 and 225A load centers.

7-24 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category RESI
Revised on 10/31/18

Circuit Breakers
Main and Branch Circuit Breakers

QS Breaker
PowerMod's core offering of residential Meter Stacks, type WMM, offers the Front View
widest product offering & flexibility in the industry. Each meter stack houses the
QuickSystem features to maximize productivity and minimize labor costs. To
further simplify installation, our 225 Amp meter stacks feature the QS breaker.
The QS breaker adds to the Siemens exclusive feature set in our Power Mod
product line. Benefits and part numbers include:

▪ An exclusive side wired design saves wiring space and eliminates


difficult "S bends"
▪ No need for costly filler plates — QS 225 Amp breaker takes the
same space as standard 100 Amp QPs
▪ Single right hand bend wiring - saves time and wire
▪ Provides 100K AIC flexibility from 100 up to 225 Amps
▪ 10K to 100K AIC Series Rating

QS Breaker
Breaker Type QS QSH QSHH HQS HQSH
Amperage 10K AIC 22K AIC 42K AIC 65K AIC 100K AIC
100 QS2100 QS2100H QSH2100 QS2100HH HQS2100H
110 QS2110 QS2110H QSH2110 QS2110HH HQS2110H
125 QS2125 QS2125H QSH2125 QS2125HH HQS2125H
150 QS2150 QS2150H QSH2150 QS2150HH HQS2150H
175 QS2175 QS2175H QSH2175 QS2175HH HQS2175H
200 QS2200 QS2200H QSH2200 QS2200HH HQS2200H
225 QS2225 QS2225H QSH2225 QS2225HH HQS2225H

QS Breaker Dimension Drawing


1.00
.19 .58 .96

7
CIRCUIT BREAKERS
MOLDED CASE
CAUTION PRECAUCION
1.38

7.89

4.31
000A
000000

ON

20 2.22
NEUTRAL
.99

20
OFF

.19

.28

1.39 1.34 .16

2.01 .37 1.06


2.38 1.16
2.56 2.12
2.66

 For PowerMod information, please refer to


Section 2, page 2-49

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-25


Circuit Breakers
Line Diagrams Dimension Drawings

1-Pole 2-Pole 3-Pole

3"
23/8"

31/8"

QP, QPH, HQP Type QT Type QPF, QPHF, QE, QAF2, QAF2H
7

Type EQ8681, EQ8682 Type EQ8693, EQ8695, EQ8696 Type QPJ


MOLDED CASE
CIRCUIT BREAKERS

Type QN, QNH, HQN Type QNR, QNRH, HQNR Type QPP, QPPH, HQPP, HQPPH

a  ll standard circuit breakers are calibrated to 40°C maxi-


A
mum ambient application.

7-26 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 10/31/18

Circuit Breakers
Lug Data Reference

Circuit Breaker Cables Connector


Circuit Breaker Type Ampere Rating Per Connector Wire Range
LOAD SIDE

QP, QPH, HQP, Plug-in 10 1 or 2 #14-#16 AWG Cu


1 #14–#6 AWG Cu
15–35
1 #14–#6 AWG Al
1 #8–#6 AWG Cu
40–50
1 #8–#4 AWG Al
1 #8-#2/0 AWG Cu
55-125
1 #8-#2/0 AWG Al

QP 1 & 2-Pole Only 55-60 1


#6-#4 AWG Cu-Al
(#3 AWG compatible with QPH & HQP)

QT 15–35
1
1
#14–#6 AWG Cu
#14–#6 AWG Al
40 1 #8 AWG CU-Al
40–50 Exception: 1 #8–#6 AWG Cu
1 & 2-pole QP at 55-60 1 #8–#4 AWG Al

QPF, QPHF 15–30


1
1
#14–#10 AWG Cu
#12–#8 AWG Al
1 #8–#6 AWG Cu
40–60
1 #8–#4 AWG Al

QAF2, QAFH2, QFGA2, 15–20


1 #14–#12 AWG Cu
QFGAH2 1 #12–#10 AWG Al

QD 15–20 2 #14–#10 AWG Cu Only


1 #14–#12 AWG Cu
15–20
1 #12–#10 AWG Al
1 #10–#8 AWG Cu
25–35
1 #10–#6 AWG Al
1 #8–#6 AWG Cu
40–60
1 #8–#4 AWG Al

QN, QNH, HQN 150–200 1 #1–300kcmil Cu-Al

QS, QSH, QSHH, HQS, HQSH 100–225 1 #3–300kcmil Cu-Al

EQ8681-Ultimate, PL, ES 100 1 #4–3/0 AWG Cu-Al

EQ8682-Ultimate, PL, ES 125 1 #4–3/0 AWG Cu-Al

7
EQ8693-Ultimate, PL, ES 150 1 #1–300kcmil Cu-Al

EQ8695-Ultimate, PL, ES

CIRCUIT BREAKERS
MOLDED CASE
200 1 #1–300kcmil Cu-Al

EQ8696-Ultimate, PL, ES 225 1 #1–300kcmil Cu-Al

QPP, QPPH, HQPP, HQPPH 125


1
1
#1 AWG Cu
#2/0 AWG Al
1 #1/0 AWG Cu
150
1 #3/0 AWG Al
1 #2/0 AWG Cu
175
1 #4/0 AWG Al
1 #3/0 AWG Cu
200
1 250kcmil AWG Al
1 #4/0 AWG Cu
225
1 300kcmil AWG Al

EQ9675-EQIII 100
1
1
#8-#2/0 AWG Cu
#8-#2/0 AWG Al

EQ9677-EQIII 125
1
1
#8-#2/0 AWG Cu
#8-#2/0 AWG Al

EQ9683-EQIII 150
1
1
#1/0 AWG Cu
#3/0 AWG Al

EQ9684 175
1
1
#3/0 AWG Cu
250kcmil AWG Al

EQ9685-EQIII 200
1
1
#2/0 AWG Cu
#4/0 AWG Al

EQ9686-EQIII 225
1
1
#4/0 AWG Cu
300kcmil AWG Al

QPJ 125–200 1 #2–300kcmil Cu-Al

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-27


Surge Protection
Circuit Breaker and Surge Protective Device (SPD)

Features Circuit Breaker and


n 2 inch wide plug-on design Surge Protective Device (SPD)
— Includes (2) 1 Pole circuits breakers
­— No loss of load center spaces
n Easy to install and perfect for retrofit
n LEDs provide protection status

Benefits
By installing a Siemens Circuit Breaker and Surge Protective Device (SPD) in the
load center of the residence, surge protection is provided for all branch circuits.

Two green LED indicator lights are provided to show that surge protection is pro-
vided for all circuits connected to the load center. These breakers should be used
for circuit protection of frequently used household or facility circuits because the
lights and devices connected to these circuits provide an effective indication that
surge protection is being provided.

The circuit breaker and SPD utilize Siemens-built 150V AC, 40mm, metal oxide
varistors (MOVs). The maximum impulse rating for the SPD module is 40kA. The
standard interrupting rating for the circuit breakers is 10k AIC. All Type QP circuit
breakers and SPD are plug-on style, with load terminals provided. The devices
are rated for 120/240V AC and are calibrated for 40 degrees C maximum ambient
applications.
Breaker Type Ampere Rating Catalog Number Surge Type
QP
(2) 15 QSA1515SPD SPD
1- Pole
120/240V AC
(2) 20 QSA2020SPD SPD
10K AIC

Catalog Number QSA1515SPD


QSA2020SPD
7

Amperage 15 or 20 Amp
Number of Poles (2) 1-Pole Circuit Breakers
MOLDED CASE
CIRCUIT BREAKERS

Initial Clamping Level 240 Volts


Transient Energy Rating 360 Joules line-to-neutral
720 Joules line-to-line
Transient Suppression 500 volts peak, line-to-neutral
Voltage Rating 1000 volts peak, line-to-line
Peak Current Rating (impulse) 40,000 amperes
Discharge Voltage Characteristic @ 1,500A, 600 volts
@ 5,000A, 800 volts
(both line-to-neutral)
Discharge Current Withstand Rating 10,000 amperes
line-to-neutral
Circuit Breaker Interrupting Rating 10,000A, 120/240V AC
Listings/Certifications UL, CSA
Meets UL 1449 4th Edition

 For warranty information please refer to the surge


website www.usa.siemens.com/surge

7-28 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category RESI
Molded Case Circuit Breakers
Panelboard Mounting with INSTA-WIRE Selection

1-Pole Bolt-On (120/240V AC)e


Type BLa Type BLHa Type HBLa

Continuous 10,000A IR 22,000A IR 65,000A IR


Current Rating
@ 40° C Catalog Number Catalog Number Catalog Number
10 B110 — —
15 B115
d B115Hd B115HHd
20 B120d B120Hd B120HHd
25 B125 B125H B125HHn
30 B130 B130H B130HH
35 B135 B135Hn B135HHn
40 B140 B140H B140HH 1-Pole
45 B145n B145Hn B145HHn
50 B150 B150H B150HHn
60 B160 B160Hn B160HHn
70 B170 B170Hn B170HHn

2-Pole Bolt-On (Common-Trip 120/240V AC)f


10 B210 — —
15 B215 B215H B215HH
20 B220 B220H B220HH
25 B225 B225Hn B225HHn
2-Pole
30 B230 B230H B230HH
35 B235 B235Hn B235HHn
40 B240 B240H B240HH
45 B245 B245Hn B245HHn
50 B250 B250H B250HH
60 B260 B260H B260HH
70 B270 B270Hn B270HHn
80 B280 B280Hn B280HHn
90 B290 B290Hn B290HHn
100 B2100 B2100H B2100HH 3-Pole
110 B2110n B2110Hn B2110HHn
125 B2125 B2125H B2125HHn

2-Pole Bolt-On (Common-Trip 240V AC)cf


15 B215R — —
20 B220R — —
30 B230R — —
40 B240Rn — —
50 B250R — —

7
3-Pole Bolt-On (Common-Trip 240V AC)g

CIRCUIT BREAKERS
MOLDED CASE
15 B315 B315H B315HH
20 B320 B320H B320HH
25 B325 B325H B325HHn
30 B330 B330H B330HH
35 B335 B335Hn B335HHn
40 B340 B340H B340HH
45 B345 B345Hn B345HHn
50 B350 B350H B350HH
60 B360 B360H B360HH Breaker Dimensions
70 B370 B370H B370HH Type Amperes L D1 D2
80 B380 B380Hn B380HH BL, BLH 15–50 39⁄16 23⁄8 3
90 B390 B390Hn B390HH BL, BLH 55–125 33⁄4 23⁄8 3
100 B3100 B3100H B3100HH HBL 15–125 33⁄4 23⁄8 3

BL/BLH/HBL Internal Accessories Modifications


Description Catalog Number Field/Factory Installed Description Catalog Number
120VAC Shunt Trip add suffix...00S01n Factory 400Hz Calibration add suffix...Yh
24VAC Shunt Trip add suffix...00S07n Factory Marine 50˚C Ambient For external
add suffix...M accessories, please
Calibration
120V Auxiliary Switch add suffix...01n b Factory refer to page 7-148
Fungus Proofing add suffix...F

c UL Listed for use on 3-phase grounded “B” systems ­­— g Shipped 4 per sleeve.
n Built to order. Allow 2-3 weeks for delivery
10,000 for this application. h ULListed 5KA IR.
a UL Listed for use with 60/75° wire through 40 amps, d UL Listed for frequent switching applications (SWD). i 10Amp breaker does not have INSTA-WIRE.
UL listed for use with 75° wire only for 50 amps e Shipped 12 per sleeve. j For 3 Phase Applications.
and above, HACR rated. 120V AC Fluorescent Lighting. f Shipped 6 per sleeve.  UL Listed for reverse feed."
b 1A and 1B contacts.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-29
Revised on 09/30/19

Molded Case Circuit Breakers


Panelboard Mounting Circuit Breakers Selection

Arc-Fault Circuit Interrupters (AFCI) • UL Listed • HACR Rated


AFCI’s detect arcing faults (an unintentional arcing condition in a circuit) that
standard circuit breakers are unable to detect. The device is intended to mitigate
the effects of arcing faults by functioning to de-energize the circuit when an arc-
fault is detected.

Combination Type AFCI


Detects all three possible types of arc fault: line-to-ground, line-to-neutral, and series.
Breaker Ampere 10,000 A IR 22,000 A IR 65,000 A IR
Type Rating Catalog Number Catalog Number Catalog Number
BAF2/BAFH2/HBAF2 15 BA115AFCa BA115AFCHn BA115AFCHHn
1-Pole 120V AC 20 BA120AFCa BA120AFCHn BA120AFCHHn
BAF/BAFH 15 B215AFCa B215AFCHn —
2-Pole 120/240V AC 20 B220AFCa B220AFCHn — 1-Pole Combination 2-Pole Combination
Type AFCI Type AFCI
Dual Function AFCI/GFCI
The Dual Function Circuit Breaker combines Combination Type AFCI and GFCI, protecting
against both Arc Faults and (5mA) Ground Faults. The device includes the Self Test
feature, making it the first in class in electrical safety for homeowners.
BFGA2/BFGAH2/ 15 B115DF B115DFHn B115DFHHn
HBFGA2 20 B120DF B120DFHn B120DFHHn
1-Pole 120V AC

Ground-Fault Circuit Ground Fault Equipment


Interrupters (GFCI) Protection (30mA)
Provides Class A (5mA) ground fault Provides protection of equipment from
protection. Intended for personnel damaging line-to-ground faults cur-
protection. De-energizes the circuit for all rents. De-energizes the circuit for all
ungrounded conductors of the circuit. ungrounded conductors of the circuit. 1-Pole Dual
Breaker Amp 10k A IR 22k A IR 65k A IR Breaker Amp 10k A IR 22k A IR Function AFCI/GFC
Type Rating Cat. No. Cat. No. Cat. No. Type Rating Cat. No. Cat. No.
BLF2/ BLE/
15 BF115Aa BF115AHa BF115AHHn
BLHF2 BLEH 15 BE115 a BE115Hna
7

20 BF120Aa BF120AHa BF120AHHn 20 BE120 a BE120Hna


1-Pole 25 BF125A BF125AHn BF125AHHn 1-Pole,
120V AC 120V AC 30 BE130 BE130Hn
30 BF130A BF130AH BF130AHHn
MOLDED CASE
CIRCUIT BREAKERS

Bolt-On Bolt-On

BLF/ 15 BF215 A BF215AHn — BLE/ 15 BE215 BE215Hn


— BLEH
BLHF 20 BF220 A BF220AH 20 BE220 BE220Hn
2-Pole 30 BF230 A BF230AH — 2-Pole 30 BE230 BE230Hn
120/240V 40 BF240 A BF240AHn — 120/240V 40 BE240 BE240Hn
AC 50 BF250 A BF250AHn — AC 50 BE250 BE250Hn
Bolt-On 60 BF260 A BF260AHn — Bolt-On 60 BE260 BE260Hn

BAF2/BLF2/BLE Accessories
1-Pole Equipment 2-Pole Equipment
Description Catalog Number
Protection Protection
Padlocking Device 1-Pole ECPLD1
Padlocking Device 2-Pole ECPLD2
Handle Block ECBX231M Wiring Diagrams

n Built to order. Allow 8 -10 weeks for delivery.


a  L Listed as SWD (Switching Duty) Rated, suitable for
U
120V AC Fluorescent Lighting.

7-30 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Molded Case Circuit Breakers
Panelboard Mounting Circuit Breakers Selection

Special Application Breakers


2-Wire 3-Wire
Switching Neutrals a
Breaker Ampere
Type Rating Catalog Number
BLG 15 BG215 n
2-Wire 20 BG220 n
Common Trip
BLG
3-Wire 30 BG330 n
Common Trip

HID Lighting a
For high-intensity discharge lamp loads having in-rush
currents above the instantaneous trip setting of a standard
breaker.
15 B115HID bn
BL 20 B120HID b
1-Pole
30 B130HID n
15 B215HID bn
BL 20 B220HID b
2-Pole
30 B230HID n Switching Neutrals

Molded Case Switch


For applications that do not require overcurrent protection.
BL 30 B230S
2-Pole

7
CIRCUIT BREAKERS
MOLDED CASE

n Built to order. Allow 2–3 weeks for delivery.


a HACR
 rated.
b UL
 Listed for frequent switching applications (SWD). 120V AC fluorescent lighting.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-31
Revised on 10/31/18

Molded Case Circuit Breakers


BQD 100A Frame Panelboard Mounting Circuit Breakers Selection/Dimensions

BQD d
1-Pole 2-Polec 3-Polec
480Y/277V AC–
Continuous Current 277V AC–125V DC 125/250V DC 480Y/277V AC
Rating @ 40°C Catalog Number Catalog Number Catalog Number
15 BQD115 a b BQD215 e BQD315e
20 BQD120 a b BQD220 e BQD320e
25 BQD125 b BQD225 e BQD325e
30 BQD130 b BQD230 e BQD330e
35 BQD135 b BQD235 e BQD335e
40 BQD140 b BQD240 e BQD340e
45 BQD145 bn BQD245 e BQD345e
50 BQD150 b BQD250 e BQD350e
60 BQD160 BQD260 BQD360
BQD, BQD6
70 BQD170n BQD270 BQD370
80 BQD180n BQD280 BQD380
90 BQD190n BQD290 BQD390
100 BQD1100n BQD2100 BQD3100

BQD6 CSA Certified


1-Pole 2-Polec 3-Polec
Continuous Current 347V AC 600/347V AC 600/347V AC
Rating @ 40°C Catalog Number Catalog Number Catalog Number
15 BQD6115 a BQD6215 BQD6315
20 BQD6120 a BQD6220 BQD6320
25 BQD6125n BQD6225n BQD6325n BQD, BQD6
30 BQD6130 BQD6230 BQD6330
35 BQD6135n BQD6235n BQD6335n Shipping Weights
40 BQD6140n BQD6240n BQD6340
Number of Number per Shipping
45 BQD6145n BQD6245n BQD6345n Poles Carton Weight (lbs.) (ea.)
50 BQD6150n BQD6250n BQD6350 1 1/12/48 1.6
60 BQD6160n BQD6260n BQD6360 2 1/6/24 1.2
70 BQD6170n BQD6270n BQD6370 3 1/4/16 2.0

Interrupting Ratings (max. RMS symmetrical amperes kA) Lugs For 60/75°C Wire
UL IEC 947-2f BQD – Load End Only
7

Volts AC 15–40 #14–#6 AWG Cu


Volts AC Volts DC 220/240 380/415 #12–#6 AWG Al
45–100 #8–#1 AWG Cu
MOLDED CASE
CIRCUIT BREAKERS

Breaker Number 480/ 600/ 125/


Type of Poles 120 240 277 277 347 347 125 250 Icu Ics Icu Ics #6–#1/0 AWG Al
BQD 1-Pole 65 — 14 — — — 14 — 18 9 — —
2-Pole — 65 — 14 — — — 14 65 33 18 9
3-Pole — 65 — 14 — — — 14 65 33 18 9
BQD6 1-Pole — — — — 10 — 14 — 18 9 — —
2-Pole — — — — — 10 — 14 65 33 18 9
3-Pole — — — — — 10 — — 65 33 18 9

For inches / millimeters conversion,


see Application Data section.
n Built to order. Allow 2–3 weeks for delivery.
c Not suitable for 3-phase delta 480V applications. For external accessories, please refer
d HACR rated. to pages 7-150 to 7-155
e HID rated at 480Y/277V AC. For internal accessories, please refer
a SWD rated for switching fluorescent lighting. f Applicable for 15-30A breakers only to page 7-35
b HID rated at 277V AC.

7-32 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 05/31/18

Molded Case Circuit Breakers


GB Frame Selection

Type NGB Frame (Panelboard Mount)


Continuous 1-Pole 2-Pole 3-Pole
Current Rating
@ 40°C Catalog Number Catalog Number Catalog Number
15 NGB1B015B a b NGB2B015B b NGB3B015B b
20 NGB1B020B a b NGB2B020B b NGB3B020B b
25 NGB1B025B b NGB2B025B b NGB3B025B b
30 NGB1B030B b NGB2B030B b NGB3B030B b
35 NGB1B035B b NGB2B035B b NGB3B035B b
40 NGB1B040B b NGB2B040B b NGB3B040B b
45 NGB1B045B b NGB2B045B b NGB3B045B b
50 NGB1B050B b NGB2B050B b NGB3B050B b
60 NGB1B060B NGB2B060B NGB3B060B
70 NGB1B070B NGB2B070B NGB3B070B
80 NGB1B080B NGB2B080B NGB3B080B
90 NGB1B090B NGB2B090B NGB3B090B
100 NGB1B100B NGB2B100B NGB3B100B
110 NGB1B110B NGB2B110B NGB3B110B NGB1B030B
125 NGB1B125B NGB2B125B NGB3B125B
Load lugs are included as standard. HACR rated.

Type HGB (Panelboard Mount) Type LGB (Panelboard Mount)


Continuous 1-Pole 2-Pole 3-Pole Continuous 1-Pole 2-Pole 3-Pole
Current Rating Current Rating
@ 40°C Catalog Number Catalog Number Catalog Number @ 40°C Catalog Number Catalog Number Catalog Number
15 HGB1B015Ba b HGB2B015Bb HGB3B015Bb 15 LGB1B015Ba b LGB2B015Bb LGB3B015Bb
20 HGB1B020Ba b HGB2B020Bb HGB3B020Bb 20 LGB1B020Ba b LGB2B020Bb LGB3B020Bb
25 HGB1B025Bb HGB2B025Bb HGB3B025Bb 25 LGB1B025Bb LGB2B025Bb LGB3B025Bb
30 HGB1B030Bb HGB2B030Bb HGB3B030Bb 30 LGB1B030Bb LGB2B030Bb LGB3B030Bb
35 HGB1B035Bb HGB2B035Bb HGB3B035Bb 35 LGB1B035Bb LGB2B035Bb LGB3B035Bb
40 HGB1B040Bb HGB2B040Bb HGB3B040Bb 40 LGB1B040Bb LGB2B040Bb LGB3B040Bb
45 HGB1B045Bb HGB2B045Bb HGB3B045Bb 45 LGB1B045Bb LGB2B045Bb LGB3B045Bb
50 HGB1B050B b
HGB2B050B b
HGB3B050B b
50 LGB1B050Bb LGB2B050Bb LGB3B050Bb
60 HGB1B060B HGB2B060B HGB3B060B 60 LGB1B060B LGB2B060B LGB3B060B
70 HGB1B070B HGB2B070B HGB3B070B 70 LGB1B070B LGB2B070B LGB3B070B
80 HGB1B080B HGB2B080B HGB3B080B 80 LGB1B080B LGB2B080B LGB3B080B
90 HGB1B090B HGB2B090B HGB3B090B 90 LGB1B090B LGB2B090B LGB3B090B

7
100 HGB1B100B HGB2B100B HGB3B100B 100 LGB1B100B LGB2B100B LGB3B100B
110 HGB1B110B HGB2B110B HGB3B110B 110 LGB1B110B LGB2B110B LGB3B110B
125 HGB1B125B HGB2B125B HGB3B125B 125 LGB1B125B LGB2B125B LGB3B125B

CIRCUIT BREAKERS
MOLDED CASE
Shipping Weights Lugs for 60/75°C Wire
Number of Number per Shipping Ampere Catalog
Poles Carton Weight lbs. (kg) Type Rating Wire Size Number
1 1 0.9 (0.4) #14-#6 AWG Cu TC1Q1 (qty. 1)
NGB 15-30A
2 1 1.9 (0.9) #12-#6 AWG Al 3TC1Q1 (qty. 3)
3 1 2.9 (1.2) HGB
LGB #8-1/0 AWG Cu
35-125A 3TC1GG20
#8-2/0 AWG Al

Interrupting Ratings (max. RMS symmetrical amperes kA)


UL489
Volts AC Volts DC
Poles 120 240 277 347 480Y/277 600Y/347 125 125/250
1 100 — 25 14 ­
— — 14 —
NGB
2,3 — 100 — — 25 14 — 14
1 100 — 35 14 — — 14 —
HGB
2,3 — 100 — — 35 14 — 14
1 100 — 65 14 — — 14 —
LGB
2,3 — 100 — — 65 14 — 14

For external accessories, please refer


a SWD rated. c 2-pole only.
to pages 7-150 to 7-155
b HID rated.  2-pole only or two outer poles of 3-pole breaker
For internal accessories, please refer
 UL Listed for reverse feed.
to page 7-35

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-33
Revised on 10/31/18

Molded Case Circuit Breakers


GB2 Frame Selection

Type NGB2g (Panelboard Mount)


Continuous 1-Pole 2-Pole 3-Pole
Current Rating
@ 40°C Catalog Number Catalog Number Catalog Number
15 NGB1K015Ba b NGB2K015Bb NGB3K015Bb
20 NGB1K020Ba b NGB2K020Bb NGB3K020Bb
25 NGB1K025Bb NGB2K025Bb NGB3K025Bb
30 NGB1K030Bb NGB2K030Bb NGB3K030Bb
35 NGB1K035Bb NGB2K035Bb NGB3K035Bb
40 NGB1K040Bb NGB2K040Bb NGB3K040Bb
45 NGB1K045Bb NGB2K045Bb NGB3K045Bb
50 NGB1K050Bb NGB2K050Bb NGB3K050Bb
60 NGB1K060B NGB2K060B NGB3K060B
70 NGB1K070B NGB2K070B NGB3K070B
80 NGB1K080B NGB2K080B NGB3K080B
90 NGB1K090B NGB2K090B NGB3K090B
100 NGB1K100B NGB2K100B NGB3K100B
110 NGB1K110B NGB2K110B NGB3K110B LGB3K125B
125 NGB1K125B NGB2K125B NGB3K125B
Load lugs are included as standard. HACR rated.

Type HGB2g (Panelboard Mount) Type LGB2g (Panelboard Mount)


Continuous 1-Pole 2-Pole 3-Pole Continuous 1-Pole 2-Pole 3-Pole
Current Rating Current Rating
@ 40°C Catalog Number Catalog Number Catalog Number @ 40°C Catalog Number Catalog Number Catalog Number
15 HGB1K015Ba b HGB2K015Bb HGB3K015Bb 15 LGB1K015Ba b LGB2K015Bb LGB3K015Bb
20 HGB1K020Ba b HGB2K020Bb HGB3K020Bb 20 LGB1K020Ba b LGB2K020Bb LGB3K020Bb
25 HGB1K025Bb HGB2K025Bb HGB3K025Bb 25 LGB1K025Bb LGB2K025Bb LGB3K025Bb
30 HGB1K030B b
HGB2K030B b
HGB3K030B b
30 LGB1K030B b
LGB2K030B b
LGB3K030Bb
35 HGB1K035Bb HGB2K035Bb HGB3K035Bb 35 LGB1K035Bb LGB2K035Bb LGB3K035Bb
40 HGB1K040Bb HGB2K040Bb HGB3K040Bb 40 LGB1K040Bb LGB2K040Bb LGB3K040Bb
45 HGB1K045Bb HGB2K045Bb HGB3K045Bb 45 LGB1K045Bb LGB2K045Bb LGB3K045Bb
50 HGB1K050Bb HGB2K050Bb HGB3K050Bb 50 LGB1K050Bb LGB2K050Bb LGB3K050Bb
60 HGB1K060B HGB2K060B HGB3K060B 60 LGB1K060B LGB2K060B LGB3K060B
70 HGB1K070B HGB2K070B HGB3K070B 70 LGB1K070B LGB2K070B LGB3K070B
80 HGB1K080B HGB2K080B HGB3K080B 80 LGB1K080B LGB2K080B LGB3K080B
90 HGB1K090B HGB2K090B HGB3K090B 90 LGB1K090B LGB2K090B LGB3K090B
7

100 HGB1K100B HGB2K100B HGB3K100B 100 LGB1K100B LGB2K100B LGB3K100B


110 HGB1K110B HGB2K110B HGB3K110B 110 LGB1K110B LGB2K110B LGB3K110B
125 HGB1K125B HGB2K125B HGB3K125B
MOLDED CASE
CIRCUIT BREAKERS

125 LGB1K125B LGB2K125B LGB3K125B

Shipping Weights Lugs for 60/75°C Wire


Number of Number per Shipping Ampere Catalog
Poles Carton Weight lbs. (kg) Type Rating Wire Size Number
1 1 .75 (.34) #14-#6 AWG Cu TC1Q1 (qty. 1)
NGB2 15-30A
#12-#6 AWG Al 3TC1Q1 (qty. 3)
2 1 1.3 (.59) HGB2
LGB2 #8-1/0 AWG Cu
3 1 2.0 (.98) 35-125A 3TC1GG20
#8-2/0 AWG Al

Interrupting Ratings (max. RMS symmetrical amperes kA)


UL 489
Volts AC Volts DC
Type Poles 120 240 277 480 347 600Y/347 125 125/250
1 100 — 25 — 14 — 14 —
NGB2
2, 3 — 100 — 25 — 14 — 14
1 100 — 35 — 22 — 14 —
HGB2
2, 3 — 100 — 35 — 22 — 14
1 100 — 65 — 25 — 14 —
LGB2
2, 3 — 100 — 65 — 25 — 14

a SWD rated.  Suitable for reverse feed applications For external accessories, please refer
b HID rated. f3 pole breakers suitable for single phase applications to pages 7-150 to 7-155
c 2-pole only. g xGB2 breakers require different strap kits than xGB. Refer to For internal accessories, please refer
 2-pole only or two outer poles of 3-pole breaker Section 11 for specific catalog numbers. to page 7-35

7-34 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 05/04/17

Molded Case Circuit Breakers


Accessoriesa Selection

Shunt Trip
BQD, BQD6, CQD, CQD6,
NGG, HGG, LGG, NGB, HGB,
Control Voltage LGB, NGB2, HGB2 and LGB2
V AC V DC Catalog Number
120 — CQDST120
240 — CQDST240s
277 — CQDST277s
480 — CQDST480s
600 — CQDST600
— 012 CQDST12
— 024 CQDST24
— 048 CQDST48
— 125 CQDST125

Auxiliary Switch
BQD, BQD6, CQD,
Maximum CQD6, NGG, HGG, LGG,
Voltage Number NGB, HGB, LGB, NGB2, CQDST120AAS
of HGB2 and LGB2
AC DC Contacts Catalog Number
240 125 1A–1B CQDA1
240 125 2A–2B CQDA2

Alarm Switch
BQD, BQD6, CQD, CQD6,
NGG, HGG, LGG, NGB, HGB,
Maximum Voltage LGB, NGB2, HGB2 and LGB2
AC DC Catalog Number

240 125 CQDBA

Shunt Trip and Auxiliary Switch


Combinations
BQD, BQD6, CQD, CQD6,

7
Shunt Trip NGG, HGG, LGG, NGB, HGB,
Voltage LGB, NGB2, HGB2 and LGB2
AC DC Catalog Number

CIRCUIT BREAKERS
MOLDED CASE
24 — CQDST24AASs
120 — CQDST120AASs
240 — CQDST240AASs CQD with Accessory Installed
277 — CQDST277AASs
480 — CQDST480AASs
600 — CQDST600AASs
— 12 CQDST12DASs
— 24 CQDST24DASs
— 48 CQDST48DASs
— 125 CQDST125DASs

Alarm and Auxiliary Switch


Combinations
For Breaker Catalog Number
BQD, BQD6, CQD, CQD6,
NGG, HGG, LGG, NGB,
CQDA1BAs
HGB, LGB, NGB2, HGB2
and LGB2

s Built to order. Allow 6–8 weeks for delivery.


aAdds 1-pole space for accessory.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-35
Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA41 125A Thermal-magnetic Trip Circuit Breakers Selection

3VA41 125A Frame, 1-Pole Thermal-Magnetic Trip Unit


Cont. S-Interrupting Class M-Interrupting Class H-Interrupting Class
Ampere (SEAB) (MEAB) (HEAB)
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFM
15 3VA41954ED140AA0 3VA41955ED140AA0 3VA41956ED140AA0
20 3VA41204ED140AA0 3VA41205ED140AA0 3VA41206ED140AA0
25 3VA41254ED140AA0 3VA41255ED140AA0 3VA41256ED140AA0
30 3VA41304ED140AA0 3VA41305ED140AA0 3VA41306ED140AA0
35 3VA41354ED140AA0 3VA41355ED140AA0 3VA41356ED140AA0
40 3VA41404ED140AA0 3VA41405ED140AA0 3VA41406ED140AA0
45 3VA41454ED140AA0 3VA41455ED140AA0 3VA41456ED140AA0
50 3VA41504ED140AA0 3VA41505ED140AA0 3VA41506ED140AA0
3VA41 125A 1-Pole
60 3VA41604ED140AA0 3VA41605ED140AA0 3VA41606ED140AA0
70 3VA41704ED140AA0 3VA41705ED140AA0 3VA41706ED140AA0
80 3VA41804ED140AA0 3VA41805ED140AA0 3VA41806ED140AA0
90 3VA41904ED140AA0 3VA41905ED140AA0 3VA41906ED140AA0
100 3VA41104ED140AA0 3VA41105ED140AA0 3VA41106ED140AA0
110 3VA41114ED140AA0 3VA41115ED140AA0 3VA41116ED140AA0
125 3VA41124ED140AA0 3VA41125ED140AA0 3VA41126ED140AA0

3VA41 125A Frame, 1 in 2-Pole Thermal-Magnetic Trip Unit


Cont. S-Interrupting Class M-Interrupting Class H-Interrupting Class
Ampere (SEAB) (MEAB) (HEAB)
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFMa
15 3VA41954ED540AA0 3VA41955ED540AA0 3VA41956ED540AA0
20 3VA41204ED540AA0 3VA41205ED540AA0 3VA41206ED540AA0
3VA41 125A 1 in 2-Pole
25 3VA41254ED540AA0 3VA41255ED540AA0 3VA41256ED540AA0
30 3VA41304ED540AA0 3VA41305ED540AA0 3VA41306ED540AA0
35 3VA41354ED540AA0 3VA41355ED540AA0 3VA41356ED540AA0
40 3VA41404ED540AA0 3VA41405ED540AA0 3VA41406ED540AA0
45 3VA41454ED540AA0 3VA41455ED540AA0 3VA41456ED540AA0
50 3VA41504ED540AA0 3VA41505ED540AA0 3VA41506ED540AA0
60 3VA41604ED540AA0 3VA41605ED540AA0 3VA41606ED540AA0
7

70 3VA41704ED540AA0 3VA41705ED540AA0 3VA41706ED540AA0


80 3VA41804ED540AA0 3VA41805ED540AA0 3VA41806ED540AA0
MOLDED CASE
CIRCUIT BREAKERS

90 3VA41904ED540AA0 3VA41905ED540AA0 3VA41906ED540AA0


100 3VA41104ED540AA0 3VA41105ED540AA0 3VA41106ED540AA0
110 3VA41114ED540AA0 3VA41115ED540AA0 3VA41116ED540AA0
125 3VA41124ED540AA0 3VA41125ED540AA0 3VA41126ED540AA0

3VA41 125A Frame, 2-Pole Thermal-Magnetic Trip Unit


S-Interrupting Class M-Interrupting Class H-Interrupting Class 3VA41 125A 2-Pole
Cont.
Ampere (SEAB) (MEAB) (HEAB)
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFM Ordering Information
15 3VA41954ED240AA0 3VA41955ED240AA0 3VA41956ED240AA0 The catalog numbers listed here are
20 3VA41204ED240AA0 3VA41205ED240AA0 3VA41206ED240AA0 for complete, non-interchangable trip
25 3VA41254ED240AA0 3VA41255ED240AA0 3VA41256ED240AA0 circuit breakers breakers with load
30 3VA41304ED240AA0 3VA41305ED240AA0 3VA41306ED240AA0 lugs installed.
35 3VA41354ED240AA0 3VA41355ED240AA0 3VA41356ED240AA0
40 3VA41404ED240AA0 3VA41405ED240AA0 3VA41406ED240AA0 All 3VA41 thermal-magnetic trip
45 3VA41454ED240AA0 3VA41455ED240AA0 3VA41456ED240AA0
circuit breakers are UL listed for
50 3VA41504ED240AA0 3VA41505ED240AA0 3VA41506ED240AA0
reverse feed applications.
60 3VA41604ED240AA0 3VA41605ED240AA0 3VA41606ED240AA0 For NAVAL-rated 1, 2 or 3-P thermal-
70 3VA41704ED240AA0 3VA41705ED240AA0 3VA41706ED240AA0 magnetic trip circuit breakers, change
80 3VA41804ED240AA0 3VA41805ED240AA0 3VA41806ED240AA0 the 13th digit of the catalog number
90 3VA41904ED240AA0 3VA41905ED240AA0 3VA41906ED240AA0 to the number "1". (For example, a
100 3VA41104ED240AA0 3VA41105ED240AA0 3VA41106ED240AA0 35KA @480VAC, 40A, 3-pole, NAVAL
110 3VA41114ED240AA0 3VA41115ED240AA0 3VA41116ED240AA0 rated 3VA41 would be catalog
125 3VA41124ED240AA0 3VA41125ED240AA0 3VA41126ED240AA0 number 3VA4140-5ED31-1AA0)

7-36 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 01/31/20
3VA Molded Case Circuit Breakers
3VA41 125A Thermal-magnetic Trip Circuit Breakers Selection

3VA41 125A Frame, 3-Pole Thermal-Magnetic Trip Unit


Cont. S-Interrupting Class M-Interrupting Class H-Interrupting Class
Ampere (SEAB) (MEAB) (HEAB)
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFM
15 3VA41954ED340AA0 3VA41955ED340AA0 3VA41956ED340AA0
20 3VA41204ED340AA0 3VA41205ED340AA0 3VA41206ED340AA0
25 3VA41254ED340AA0 3VA41255ED340AA0 3VA41256ED340AA0
30 3VA41304ED340AA0 3VA41305ED340AA0 3VA41306ED340AA0
35 3VA41354ED340AA0 3VA41355ED340AA0 3VA41356ED340AA0
40 3VA41404ED340AA0 3VA41405ED340AA0 3VA41406ED340AA0
45 3VA41454ED340AA0 3VA41455ED340AA0 3VA41456ED340AA0
50 3VA41504ED340AA0 3VA41505ED340AA0 3VA41506ED340AA0 3VA41 125A 3-Pole
60 3VA41604ED340AA0 3VA41605ED340AA0 3VA41606ED340AA0
70 3VA41704ED340AA0 3VA41705ED340AA0 3VA41706ED340AA0
80 3VA41804ED340AA0 3VA41805ED340AA0 3VA41806ED340AA0 Trip Settings for 3VA41
90 3VA41904ED340AA0 3VA41905ED340AA0 3VA41906ED340AA0
TM210 - FTFM
100 3VA41104ED340AA0 3VA41105ED340AA0 3VA41106ED340AA0
In (A)
Ir (A) Ii (A)
110 3VA41114ED340AA0 3VA41115ED340AA0 3VA41116ED340AA0
15 15 300
125 3VA41124ED340AA0 3VA41125ED340AA0 3VA41126ED340AA0
20 20 300
25 25 300
Interrupting Ratings for 3VA41 30 30 300
RMS Symmetrical Amperes (kA) 35 35 350
Inter-
Volts AC (50/60 Hz) 40 40 400
rupting Breaker
Class Type Poles 120 240 277 347 480Y/277V 480 600Y/347V 45 45 450
50 50 500
1 65 25 14
S SEAB 60 60 600
2, 3 65 25 25 14
70 70 700
1 85 35 18 3VA UL Molded Case Circuit 80Breakers 80 800
M MEAB
2, 3 85 35 35 Accessories
18 and Spare Parts 90 90 900
1 150 65 25 100 100 1000
H HEAB
2, 3 150 65 65 Internal accessories
25 110 110 1100
Design 125 125 1250
Dimensions Shipping Weight
Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg
Internal accessories configuration 3VA4/3VA5 3VA4
3VA41 1 1 (25.4) 5.1 (129.4) 3.6 (92.2) 0.62 0.28

7
125 A 125 A
3VA41 1 in 2 2 (50.8) 5.1 (129.4) 3.6 (92.2) 0.94 0.43 1 in 2-pole 3-pole
/2-pole
3VA41 2 2 (50.8) 5.1 (129.4) 3.6 (92.2) 1.13 0.51

CIRCUIT BREAKERS
MOLDED CASE
3VA41 3 3 (76.2) 5.1 (129.4) 3.6 (92.2) 1.64 0.74
125 A 125 A

Connectors for 75C Wire for 3VA41 Slot No.: 23 22 21 23 22 21 11 12 13


Min. Max. Catalog No. Auxiliary switch Type
Type cable size cable size (kit of 3 lugs) AUX_HQ x x x x x x x x x
Steel wrap around (Cu cable only), AUX_HQ_el x x x x x x x x x
AWG 14 3/0 3VA9133-0JA11 Auxiliary switch
1 cable lugs x x x
AUX_HP
Aluminum body lug small (Cu/Al x x x
AWG 14 AWG 10 3VA9133-0JB10
cable), 1 cable lug LCS_HQ x
Aluminum body lug (Cu/Al cable), Leading
AWG 14 3/0 3VA9133-0JB11 changeover switch
LCS_HQ_el x
1 cable lugs
LCS_HP x
Aluminum body lug small with control
AWG 14 AWG 10 3VA9133-0JG10 Alarm switch Type
wire tap (Cu/Al cable), 1 cable lug
TAS_HQ x x x x x x
Aluminum body lug with control wire
AWG 14 3/0 3VA9133-0JG11
tap (Cu/Al cable), 1 cable lugs Trip alarm switch TAS_HQ_el x x x x x x
Copper body lug small (Cu cable only), TAS_HP x x x
AWG 14 AWG 10 3VA9133-0JD10
1 cable lugs SAS_HQ
Short circuit alarm switch
Copper body lug (Cu cable only), SAS_HQ_el
AWG 14 2/0 3VA9133-0JD11
1 cable lugs
Auxiliary release Type
Copper body lug small with control
wire tap (Cu cable only), 1 cable lugs
AWG 14 AWG 10 3VA9133-0JK10
4 Shunt trip flexible STF
STL
x
x
x
x
Copper body lug with control wire tap Shunt trip left
AWG 14 2/0 3VA9133-0JK11 STL_el
(Cu cable only), 1 cable lugs
Residual current release RCR

3VA4 Accessories Undervoltage release

Universal release
UVR
UNI
x
x
x
x
Description Catalog Number Other
Padlocking Device for 3VA4 breaker 3VA9038-0LB11 Cylinder lock (type Ronis) x

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-37


Revised on 10/31/18

Circuit Breakers
Lug-In/Lug-Out with INSTA-WIRE Selection

All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix “L” to catalog number. Consult Siemens
for any additional charge. All standard circuit breakers are calibrated for 40°C maximum ambient application.

Type BQ Type BQH Type HBQ


Continuous
Current Rating 10,000A IR 22,000A IR 65,000A IR
@ 40° C Catalog Number Catalog Number Catalog Number
1-Pole (120/240V AC)e
15 BQ1B015d BQ1B015Hd HB1B015nd
20 BQ1B020d BQ1B020Hd HB1B020nd
25 BQ1B025 BQ1B025Hn HB1B025n
30 BQ1B030 BQ1B030H HB1B030n
35 BQ1B035n BQ1B035Hn HB1B035n
40 BQ1B040 BQ1B040H HB1B040n
45 BQ1B045n — HB1B045n
50 BQ1B050 BQ1B050H HB1B050n 1-Pole
60 BQ1B060n BQ1B060Hn HB1B060n
70 BQ1B070n BQ1B070Hn HB1B070n
2-Pole (Common-Trip 120/240V AC)f
15 BQ2B015 BQ2B015H HB2B015n
20 BQ2B020 BQ2B020H HB2B020n
25 BQ2B025 BQ2B025Hn HB2B025n
30 BQ2B030 BQ2B030H HB2B030n
35 BQ2B035 BQ2B035Hn HB2B035n
40 BQ2B040 BQ2B040H HB2B040n
45 BQ2B045 — HB2B045n
50 BQ2B050 BQ2B050H HB2B050n
60 BQ2B060 BQ2B060H HB2B060n
70 BQ2B070 BQ2B070Hn HB2B070n
80 BQ2B080 BQ2B080Hn HB2B080
90 BQ2B090 BQ2B090Hn HB2B090n 2-Pole
100 BQ2B100 BQ2B100H HB2B100
110 BQ2B110 — HB2B110n
125 BQ2B125 BQ2B125H HB2B125
2-Pole (Common-Trip 240V AC)cf
15 BQ2H015 — —
20 BQ2H020 — —
30 BQ2H030 — —
40 BQ2H040n — —
50 BQ2H050 — —
60 BQ2H060 — —
70 BQ2H070n — —
7

80 BQ2H080n — —
90 BQ2H090n — —
MOLDED CASE
CIRCUIT BREAKERS

100 BQ2H100n — —
3-Pole
3-Pole (Common-Trip 240V AC)g
15 BQ3B015 BQ3B015H HB3B015n
20 BQ3B020 BQ3B020H HB3B020n
25 BQ3B025n BQ3B025Hn HB3B025
30 BQ3B030 BQ3B030H HB3B030
35 BQ3B035n BQ3B035H HB3B035
40 BQ3B040 BQ3B040H HB3B040
45 BQ3B045n BQ3B045H HB3B045
50 BQ3B050 BQ3B050H HB3B050
60 BQ3B060 BQ3B060H HB3B060 Factory Modifications
70 BQ3B070 BQ3B070H HB3B070n Description Catalog Number
80 BQ3B080 BQ3B080Hn HB3B080n Line Side Lugs add suffix...L
90 BQ3B090 BQ3B090Hn HB3B090n Quick Connect Lug add suffix...QX
100 BQ3B100 BQ3B100H HB3B100
400Hz Calibration add suffix...Y h
Marine 50˚ C Ambient
add suffix...M
Calibration
BQ / BQH / HBQ Internal Accessories Fungus Proofing add suffix...F
Description Catalog Number Field/Factory Installed
120VAC Shunt Trip add suffix...00S01n Factory
24VAC Shunt Trip add suffix...00S07n Factory For external accessories, please refer
to page 7-148
120V Auxiliary Switch add suffix...01nb Factory

n Built to order. Allow 2-3 weeks for delivery b 1A and 1B contacts. e Shipped
 12 per sleeve.
c UL
 Listed for use on 3-phase grounded “B” systems ­­— f Shipped
 6 per sleeve.
a ULListed for use with 60/75° wire through 40 amps, 10,000 for this application. g Shipped
 4 per sleeve.
UL listed for use with 75° wire only for 50 amps d UL
 Listed for frequent switching h UL
 Listed 5KA IR.
and above, HACR rated. applications (SWD). 120V AC Fluorescent Lighting.  Refer to Table A on page 7-143

7-38 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 11/30/19

Molded Case Circuit Breakers


DIN Rail Mounted Circuit Breakers Selection/Dimensions

Interrupting Ratings
(KA) (RMS Symmetrical
Breaker Ampere Catalog Line Side Load Side Amperes) Volts AC
Type Rating Number Connector Connector 120 120/240

1-Pole DIN Rail (120/240V AC)


10 BQ1B010QLD TC1Q1 TC1Q1 10
15 BQ1B015QLD TC1Q1 TC1Q1 10
20 BQ1B020QLD TC1Q1 TC1Q1 10
BQLD 25 BQ1B025QLD TC1Q1 TC1Q1 10
1-Pole 30 BQ1B030QLD TC1Q1 TC1Q1 10
120V 35 BQ1B035QLD TC1Q1 TC1Q1 10
DIN Rail 40 BQ1B040QLD TC1Q1 TC1Q1 10
45 BQ1B045QLD TA1Q1 TA1Q1 10
50 BQ1B050QLD TA1Q1 TA1Q1 10
60 BQ1B060QLD TA1Q1 TA1Q1 10
10 BQ1B010QXD TC1Q1 Quick-Connect 10 BQ1B015QLD BQ2B015QLD
15 BQ1B015QXD TC1Q1 Quick-Connect 10
20 BQ1B020QXD TC1Q1 Quick-Connect 10
BQXD 25 BQ1B025QXD TC1Q1 Quick-Connect 10
1-Pole 30 BQ1B030QXD TC1Q1 Quick-Connect 10
120V 35 BQ1B035QXD TC1Q1 Quick-Connect 10
DIN Rail 40 BQ1B040QXD TC1Q1 Quick-Connect 10
45 BQ1B045QXD TA1Q1 Quick-Connect 10
50 BQ1B050QXD TA1Q1 Quick-Connect 10
60 BQ1B060QXD TA1Q1 Quick-Connect 10
2-Pole DIN Rail (120/240V AC)
10 BQ2B010QLD TC1Q1 TC1Q1 10
15 BQ2B015QLD TC1Q1 TC1Q1 10
20 BQ2B020QLD TC1Q1 TC1Q1 10
BQLD 25 BQ2B025QLD TC1Q1 TC1Q1 10
2-Pole 30 BQ2B030QLD TC1Q1 TC1Q1 10
120/240V 35 BQ2B035QLD TC1Q1 TC1Q1 10 BQ1B015QXD BQ2B015QXD
DIN Rail 40 BQ2B040QLD TC1Q1 TC1Q1 10
45 BQ2B045QLD TA1Q1 TA1Q1 10
50 BQ2B050QLD TA1Q1 TA1Q1 10
60 BQ2B060QLD TA1Q1 TA1Q1 10
10 BQ2B010QXD TC1Q1 Quick-Connect 10
15 BQ2B015QXD TC1Q1 Quick-Connect 10
20 BQ2B020QXD TC1Q1 Quick-Connect 10
BQXD 25 BQ2B025QXD TC1Q1 Quick-Connect 10
2-Pole 30 BQ2B030QXD TC1Q1 Quick-Connect 10
120/240V 35 BQ2B035QXD TC1Q1 Quick-Connect 10
DIN Rail 40 BQ2B040QXD TC1Q1 Quick-Connect 10
45 BQ2B045QXD TA1Q1 Quick-Connect 10
50 BQ2B050QXD TA1Q1 Quick-Connect 10

7
60 BQ2B060QXD TA1Q1 Quick-Connect 10

CIRCUIT BREAKERS
MOLDED CASE
Lugs-For Use with BQXD BQ Enclosures
Circuit Cab. Lug Type Catalog Number d
Breaker Per Wire Range Catalog
Amp. Rtg. Lug AWG Number 1 EB3100S c
Line Side 3R WB3100
10–40 1 #16–#6 Cu
1 #12–#6 Al TC1Q1 a b
45–125 1 #8–#1 Cu BQ Breaker Dimensions
1 #6–#1/0 Al TA1Q1
Dimensions (inches)
Number of Poles Breaker Type Amperes L D1 D2
Finger Safe Terminal Shield
Protects against accidental contact with 1, 2 BQ 15-50 3¾ 23⁄8 3
lugs–1 per lug. Fits line and load end. 1, 2 BQH, HBQ 15-50 4 23⁄8 3
Catalog Number Qty 1, 2 BQ, BQH, HBQ 55-125 4 23⁄8 3
BQFS2 2 3 BQ, BQH, HBQ 15-100 4 23⁄8 3
BQFS1K 1000 1, 2 BQXD 15-60 4½ 23⁄8 3

For inches / millimeters conversion, bConnector has steel construction. Type BQXD uses TA1Q1 or TC1Q1 lugs on line side of
see Application Data section. cSurface mounted indoor. If flush mounting is required, circuit breaker.
replace suffix “S” in catalog number with suffix “F”.
n Built to order. Allow 2–3 weeks for delivery. Neutral included in enclosure.
a UL
Enclosures, see Section 6
Listed for use with 60/75° wire through 40 amps, Enclosure will not accept circuit breakers with shunt
UL listed for use with 75° wire only for 50 amps For external accessories, please refer
trips or auxiliary switches installed.
and above, HACR rated. to pages 7-148, 7-150 to 7-155

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-39
Revised on 05/04/17

Molded Case Circuit Breakers


QR 250A Frame Selection/Dimensions

Continuous 2-Pole 3-Pole Ordering Information


Current Rating 240V AC 240V AC
@ 40°C Catalog Number Catalog Number Load side 3TA1QR300 lugs are mounted and included
when circuit breaker is ordered. For line and load lugs
Type QR2b (3TA1QR300) installed at no additional charge, add
suffix “L” to catalog number.
100 QR22B100 QR23B100
50°C Calibration - See page 7-146.
125 QR22B125 QR23B125 400HZ. - See page 7-146.
150 QR22B150 QR23B150
175 QR22B175 QR23B175
200 QR22B200 QR23B200
Shipping Weights
225 QR22B225 QR23B225 Number Number Shipping
of Poles per Carton Weight (lbs.)
250 QR22B250 QR23B250
2 1 3.2
Type QRH2b 3 1 4.5
100 QRH22B100n QRH23B100
125 QRH22B125 QRH23B125 Lugs For 75°C Wire a
150 QRH22B150 QRH23B150 Catalog Lug Lug
175 QRH22B175n QRH23B175 Number Body Wire Range
200 QRH22B200 QRH23B200 3TA1QR300 Al #3 - 300 Kcmil Al/Cu
225 QRH22B225 QRH23B225
3TC1QR250 Cu #3 - 300 Kcmil Cu ONLY
250 QRH22B250 QRH23B250
CCQ250 CMP #6 AWG - 350kcmil Al/Cu
Type HQR2b
100 HQR22B100n HQR23B100
Enclosures (Neutral Included)
125 HQR22B125 HQR23B125
Catalog
150 HQR22B150 HQR23B150 Type Number
175 HQR22B175n HQR23B175 1 QR2N1S or QR2N1F
200 HQR22B200 HQR23B200
3R QR2N3R3
225 HQR22B225 HQR23B225
12 QR2N12
250 HQR22B250 HQR23B250
4X QR2N4X
Type HQR2Hb 4X316 QR2N4X316
100 HQR22B100H HQR23B100H
125 HQR22B125H HQR23B125H UL 489 Interrupting Ratings
150 HQR22B150H HQR23B150H RMS Symmetrical Amperes (kA)
Breaker Volts AC (50/60 Hz)
7

175 HQR22B175H HQR23B175H


Type 240
200 HQR22B200H HQR23B200H QR2 10
MOLDED CASE
CIRCUIT BREAKERS

225 HQR22B225H HQR23B225H QRH2 25


250 HQR22B250H HQR23B250H HQR2 65
HQR2H 100

7’’

3’’
2.5 D
3’’

2-pole
4.5’’ 3-pole

n Built to order. Allow 2–3 weeks for delivery. a See Note: A page 7-137.
Note: QR breakers are UL Listed for reverse feed
applications. Enclosures Section 6
b HACR rated. For external accessories, please refer
to pages 7-150 to 7-155

7-40 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 04/10/17

Molded Case Circuit Breakers


QR Accessories Selection

Shunt Trip
Shunt Trip and Auxiliary
Control Voltage Shunt Trip Switch Combination
AC DC In Rush Catalog Number Catalog Number
— 24 1.1A S07QR2 S07QR2A
120 - 240 48 2.0A AC / 1.8A DC S01QR2 S01QR2A

Auxiliary Switch
Contains (1) or (2) sets of “A” contacts and “B” contacts

Maximum Control Maximum Allowable Single Auxiliary 1A -1B Double Auxiliary 2A - 2B


Supply Voltage (V) Current (A) Contact Catalog Number Contact Catalog Number

250 AC /125 DC 5 AC / 0.5 DC A01QR2 A02QR2

External Accessories
Description Catalog Number
Padlock Device HPLQR

Mounting Screw Kit MSQR3

Handle Blocking Device HBLQR

Handle Sliding-bar Interlock SBMIQR

Padlock
Padlock
Device
Device
Padlock HPLQR
HPLQR
Device HPLQR Handle
HandleBlock
HandleBlock
Device
Device
Block HBLQR
HBLQR
Device HBLQR Mechanical
MechanicalInterlock
MechanicalInterlock
SBMIQR
SBMIQR
Interlock SBMIQR

7
CIRCUIT BREAKERS
MOLDED CASE

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-41


Revised on 05/31/18

Molded Case Circuit Breakers


CQD 100A Frame Selection/Dimensions

Type CQD (Cable In - Cable Out) DIN Rail Mountc Shipping Weights
1-Pole 2-Pole 3-Pole Number of Number per Shipping
Continuous 277V AC 480Y/277V AC Poles Carton Weight lbs. (kg)
Current Rating 125V DC 125/250V DC 480Y/277V AC 1 1 0.5 (0)
@ 40°C Catalog Number Catalog Number Catalog Number 2 1 1.0 (0)
115 CQD115 ab CQD215b CQD315b 3 1 1.5 (1)
120 CQD120 ab CQD220b CQD320b
125 CQD125 b CQD225b CQD325b
130 CQD130 b CQD230b CQD330b Lugs For 60/75°C Wire
135 CQD135bn CQD235bn CQD335b
Amps Wire Size
140 CQD140bn CQD240b CQD340b
15–40 #14–#6 AWG Cu
145 CQD145bn CQD245bn CQD345bn
#12–#6 AWG Al
150 CQD150bn CQD250b CQD350b
160 CQD160n CQD260 CQD360 45–100 #8–#1 AWG Cu
#6–#1/0 AWG Al
170 CQD170n CQD270 CQD370
180 CQD180n CQD280 CQD380
190 CQD190n CQD290n CQD390
100 CQD1100n CQD2100 CQD3100

Interrupting Ratings (max. RMS symmetrical amperes kA)


UL IEC 947-2d
Volts AC
Volts AC Volts DC 220/240 380/415
Breaker Number 480/ 600/ 125/
Type of Poles 120 240 277 277 347 125 250 Icu Ics Icu Ics
1-Pole 65 — 14 — — 14 — 18 9 — — CQD
CQD 2-Pole — 65 — 14 — — 14 65 33 18 9
3-Pole — 65 — 14 — — 14 65 33 18 9
7

CQD
MOLDED CASE
CIRCUIT BREAKERS

For inches / millimeters conversion, see Application Data section.

n Built to order. Allow 2–3 weeks for delivery. b HID rated.


c HACR rated.
a SWD rated. Enclosures Section 6
d Applicable for 15-30A breakers only.
Note: CQD breakers are UL Listed for reverse feed Accessories pages 7-44 and 7-150 to 7-155
applications.

7-42 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 11/30/19

Molded Case Circuit Breakers


GG 125A Frame Selection/Dimensions

Type NGG (Cable In - Cable Out)


Continuous 1-Pole 2-Pole 3-Pole
Current Rating
@ 40°C Catalog Number Catalog Number Catalog Number
15 NGG1B015La b NGG2B015Lb NGG3B015Lb
20 NGG1B020La b NGG2B020Lb NGG3B020Lb
25 NGG1B025Lb NGG2B025Lb NGG3B025Lb
30 NGG1B030Lb NGG2B030Lb NGG3B030Lb
35 NGG1B035Lb NGG2B035Lb NGG3B035Lb GG
40 NGG1B040Lb NGG2B040Lb NGG3B040Lb
45 NGG1B045Lb NGG2B045Lb NGG3B045Lb
50 NGG1B050Lb NGG2B050Lb NGG3B050Lb
2.9
60 NGG1B060L NGG2B060L NGG3B060L
70 NGG1B070L NGG2B070L NGG3B070L
80 NGG1B080L NGG2B080L NGG3B080L
5.4
90 NGG1B090L NGG2B090L NGG3B090L
100 NGG1B100L NGG2B100L NGG3B100L

110 NGG1B110L NGG2B110L NGG3B110L


125 NGG1B125L NGG2B125L NGG3B125L

Line and load lugs are included as standard. If no lugs are required, remove the “L” suffix.
HACR rated. GG
Suitable for screws or DIN rail mounting.

Type HGG (Cable In - Cable Out) Type LGG (Cable In - Cable Out)
Continuous Continuous
1-Pole 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole
Current Rating Current Rating
@ 40°C Catalog Number Catalog Number Catalog Number @ 40°C Catalog Number Catalog Number Catalog Number
15 HGG1B015Lb HGG2B015Lb HGG3B015Lb 15 LGG1B015Lb LGG2B015Lb LGG3B015Lb
20 HGG1B020Lb HGG2B020Lb HGG3B020Lb 20 LGG1B020Lb LGG2B020Lb LGG3B020Lb
25 HGG1B025Lb HGG2B025Lb HGG3B025Lb 25 LGG1B025Lb LGG2B025Lb LGG3B025Lb
30 HGG1B030Lb HGG2B030Lb HGG3B030Lb 30 LGG1B030Lb LGG2B030Lb LGG3B030Lb
35 HGG1B035Lb HGG2B035Lb HGG3B035Lb 35 LGG1B035Lb LGG2B035Lb LGG3B035Lb
40 HGG1B040Lb HGG2B040Lb HGG3B040Lb 40 LGG1B040Lb LGG2B040Lb LGG3B040Lb
45 HGG1B045Lb HGG2B045Lb HGG3B045Lb 45 LGG1B045Lb LGG2B045Lb LGG3B045Lb
50 HGG1B050Lb HGG2B050Lb HGG3B050Lb 50 LGG1B050Lb LGG2B050Lb LGG3B050Lb
60 HGG1B060L HGG2B060L HGG3B060L 60 LGG1B060L LGG2B060L LGG3B060L
70 HGG1B070L HGG2B070L HGG3B070L 70 LGG1B070L LGG2B070L LGG3B070L
80 HGG1B080L HGG2B080L HGG3B080L 80 LGG1B080L LGG2B080L LGG3B080L

7
90 HGG1B090L HGG2B090L HGG3B090L 90 LGG1B090L LGG2B090L LGG3B090L
100 HGG1B100L HGG2B100L HGG3B100L 100 LGG1B100L LGG2B100L LGG3B100L

CIRCUIT BREAKERS
MOLDED CASE
110 HGG1B110L HGG2B110L HGG3B110L 110 LGG1B110L LGG2B110L LGG3B110L
125 HGG1B125L HGG2B125L HGG3B125L 125 LGG1B125L LGG2B125L LGG3B125L

Shipping Weights Lugs For 60/75°C Wire


Number of Number per Shipping NGG
Poles Carton Weight lbs. (kg)
Ampere Rating Wire Size Catalog Number
1 1 .75 (0.34)
15–30A #14–#6 AWG Cu TC1Q1 (qty. 1)
2 1 1.3 (0.59)
#12–#6 AWG Al 3TC1Q1 (qty. 3)
3 1 2.0 (0.98)
35–125A #8–1/0 AWG Cu
3TC1GG20 (qty. 3)
#8–2/0 AWG Al
15–125A Nut Keeper plate w/ screw
TNKG3 (qty. 3)
(for crimp terminals)

Interrupting Ratings (max. RMS symmetrical amperes kA)


UL489 IEC 60947-2 (Ics = 50%Icu)
Breaker Volts AC Volts DC Volts AC Volts DC
Type Poles 120 240 277 347 480 600Y/347 125 125/250 240 415 125/250
1 65 — 25 14 ­
— — 14 — 25 — —
NGG
2,3 — 65 — — 25 14 — 14 65 — 14
1 — — 35 14 — — 14 — — — —
HGG
2,3 — — — — 35 14 — 14 — — —
1 — — 65 14 — — 14 — — — —
LGG
2,3 — — — — 65 14 — 14 — — —

For inches / millimeters conversion, see Application Data section.


b HID
 rated at 15-50A 1-pole @ 277 VAC; 2 & 3-pole @
Enclosures Section 6
a SWD rated.
480 VAC
Accessories pages 7-44 and 7-150 to 7-155

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-43
Molded Case Circuit Breakers
Accessoriesa Selection

Shunt Trip
BQD, BQD6, CQD,
NGG, HGG, LGG, NGB,
Control Voltage HGB and LGB
V AC V DC Catalog Number
120 — CQDST120
240 — CQDST240s
277 — CQDST277s
480 — CQDST480s
600 — CQDST600
— 012 CQDST12
— 024 CQDST24
— 048 CQDST48
— 125 CQDST125

Auxiliary Switch
BQD, BQD6, CQD,
Maximum Number NGG, HGG, LGG, NGB,
Voltage of HGB and LGB CQDST120AAS
AC DC Contacts Catalog Number
240 125 1A–1B CQDA1
240 125 2A–2B CQDA2

Alarm Switch
BQD, BQD6, CQD,
NGG, HGG, LGG, NGB,
Maximum Voltage HGB and LGB
AC DC Catalog Number

240 125 CQDBA

Shunt Trip and Auxiliary Switch


Combinations
BQD, BQD6, CQD,
Shunt Trip
7

NGG, HGG, LGG, NGB,


Voltage HGB and LGB
AC DC Catalog Number
MOLDED CASE
CIRCUIT BREAKERS

24 — CQDST24AASs
120 — CQDST120AASs
240 — CQDST240AASs
CQD with Accessory Installed
277 — CQDST277AASs
480 — CQDST480AASs
600 — CQDST600AASs
— 12 CQDST12DASs
— 24 CQDST24DASs
— 48 CQDST48DASs
— 125 CQDST125DASs

Alarm and Auxiliary Switch


Combinations
For Breaker Catalog Number
BQD, BQD6, CQD, NGG,
HGG, LGG, NGB, HGB CQDA1BAs
and LGB

s Built to order. Allow 6–8 weeks for delivery.


aAdds 1-pole space for accessory.

7-44 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 12/31/19

3VA Molded Case Circuit Breakers


3VA UL Circuit Breakers Catalog Numbering System

3VA 6 1 40 – 5 HL 3 1 – 0 A A0
Breaker Designation
Thermal magnetic panelboard breakers 4
Thermal magnetic (Cable-in Cable-out) breakers 5
Electronic trip breakers 6
Frame Size
125/150A 1
250A 2
400A 3
600A 4
Rated Current
3VA41/3VA51 3VA52 3VA53 3VA54 3VA61 3VA62 3VA63 3VA64
15A 95
20A 200A 200A 20
225A 225A 22
25A 250A 250A 250A 250A 25
30A 300A 30
35A 350A 35
40A 40A 400A 40A 400A 400A 40
45A 45A 450A 45
50A 50A 500A 50
60A 60A 600A 600A 60
70A 70A 70
80A 80A 80
90A 90A 90
100A 100A 100A 100A 10
110A 110A 11
125A 125A 12
150A 150A 15
175A 17
Interrupting Capacity @ 480V
3VA4/3VA5 3VA6
MCP/MCS 0
MCP/MCS MCP/MCS 1
25K 4
35K 35K 5
65K 65K 6
100K 100K 7
150K 8
Trip Unit Protection Functions
3VA4/3VA5 L I N
TM230 MCCB fix adj EC
TM210 MCCB fix fix ED
TM240 MCCB adj adj EF
TM230 MCCB fix adj 100% GC
TM210 MCCB fix fix 100% GD

7
TM240 MCCB adj adj 100% GF
TM110M MSP fix MG
TM120M MSP adj MH

CIRCUIT BREAKERS
MOLDED CASE
TM120M MSP adj MU
MCS110 MSC fix BB
3VA6 L S I G N LCD com. measurement values
ETU320 LI MCCB adj adj 0%/50%/100% HL
ETU330 LIG MCCB adj adj adj 0%/50%/100% HM
ETU350 LSI MCCB adj adj fix 0%/50%/100% HN
ETU550 LSI MCCB adj adj adj 20/40%...100/160% yes yes standard JP
ETU556 LSI(G) MCCB adj adj adj alarm 20/40%...100/160% yes yes standard JT
ETU560 LSIG MCCB adj adj adj adj 20/40%...100/160% yes yes standard JQ
ETU820 LI MCCB adj adj 20/40%...100/160% yes yes advanced KL
ETU830 LIG MCCB adj adj adj 20/40%...100/160% yes yes advanced KM
ETU850LSI MCCB adj adj adj 20/40%...100/160% yes yes advanced KP
ETU856 LSI(G) MCCB adj adj adj alarm 20/40%...100/160% yes yes advanced KT
ETU860 LSIG MCCB adj adj adj adj 20/40%...100/160% yes yes advanced KQ
ETU310M MCP adj MS
MCS110 MCS fix BB
Number of Poles
1 pole 1
2 pole 2
3 pole 3
4 pole 4
1-in-2 pole 5
2-in-3 pole 6
Connection Technology
blank, punched copper bar without any lugs 1
Regional Specifics (as applicable)
Standard 0
NAVAL/50C 1
100% Rated (3VA6) 2
Auxixliary Releases Without A
Auxiliary/Alarm Switches Without A0

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-45


Revised on 02/28/19

3VA Molded Case Circuit Breakers


3VA51 125A Thermal-magnetic Trip Circuit Breakers Selection

3VA51 125A Frame, 1-Pole Thermal-Magnetic Trip Unit


Cont. S-Interrupting Class M-Interrupting Class H-Interrupting Class
Ampere (SEAS) (MEAS) (HEAS)
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFM
15 3VA5195-4ED11-0AA0 3VA5195-5ED11-0AA0 3VA5195-6ED11-0AA0
20 3VA5120-4ED11-0AA0 3VA5120-5ED11-0AA0 3VA5120-6ED11-0AA0
25 3VA5125-4ED11-0AA0 3VA5125-5ED11-0AA0 3VA5125-6ED11-0AA0
30 3VA5130-4ED11-0AA0 3VA5130-5ED11-0AA0 3VA5130-6ED11-0AA0
35 3VA5135-4ED11-0AA0 3VA5135-5ED11-0AA0 3VA5135-6ED11-0AA0
40 3VA5140-4ED11-0AA0 3VA5140-5ED11-0AA0 3VA5140-6ED11-0AA0
45 3VA5145-4ED11-0AA0 3VA5145-5ED11-0AA0 3VA5145-6ED11-0AA0
50 3VA5150-4ED11-0AA0 3VA5150-5ED11-0AA0 3VA5150-6ED11-0AA0 3VA51 125A 1-Pole
60 3VA5160-4ED11-0AA0 3VA5160-5ED11-0AA0 3VA5160-6ED11-0AA0
70 3VA5170-4ED11-0AA0 3VA5170-5ED11-0AA0 3VA5170-6ED11-0AA0
80 3VA5180-4ED11-0AA0 3VA5180-5ED11-0AA0 3VA5180-6ED11-0AA0
90 3VA5190-4ED11-0AA0 3VA5190-5ED11-0AA0 3VA5190-6ED11-0AA0
100 3VA5110-4ED11-0AA0 3VA5110-5ED11-0AA0 3VA5110-6ED11-0AA0
110 3VA5111-4ED11-0AA0 3VA5111-5ED11-0AA0 3VA5111-6ED11-0AA0
125 3VA5112-4ED11-0AA0 3VA5112-5ED11-0AA0 3VA5112-6ED11-0AA0

3VA51 125A Frame, 2-Pole Thermal-Magnetic Trip Unit


Cont. S-Interrupting Class M-Interrupting Class H-Interrupting Class
Ampere (SEAS) (MEAS) (HEAS)
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFMa
15 3VA5195-4ED21-0AA0 3VA5195-5ED21-0AA0 3VA5195-6ED21-0AA0
20 3VA5120-4ED21-0AA0 3VA5120-5ED21-0AA0 3VA5120-6ED21-0AA0
25 3VA5125-4ED21-0AA0 3VA5125-5ED21-0AA0 3VA5125-6ED21-0AA0
30 3VA5130-4ED21-0AA0 3VA5130-5ED21-0AA0 3VA5130-6ED21-0AA0
3VA51 125A 2-Pole
35 3VA5135-4ED21-0AA0 3VA5135-5ED21-0AA0 3VA5135-6ED21-0AA0
40 3VA5140-4ED21-0AA0 3VA5140-5ED21-0AA0 3VA5140-6ED21-0AA0
45 3VA5145-4ED21-0AA0 3VA5145-5ED21-0AA0 3VA5145-6ED21-0AA0 Ordering Information
50 3VA5150-4ED21-0AA0 3VA5150-5ED21-0AA0 3VA5150-6ED21-0AA0
The catalog numbers listed here are
7

60 3VA5160-4ED21-0AA0 3VA5160-5ED21-0AA0 3VA5160-6ED21-0AA0


70 3VA5170-4ED21-0AA0 3VA5170-5ED21-0AA0 3VA5170-6ED21-0AA0 for complete, non-interchangable trip
80 3VA5180-4ED21-0AA0 3VA5180-5ED21-0AA0 3VA5180-6ED21-0AA0 circuit breakers without lugs.
MOLDED CASE
CIRCUIT BREAKERS

90 3VA5190-4ED21-0AA0 3VA5190-5ED21-0AA0 3VA5190-6ED21-0AA0 Order required lugs or connection


100 3VA5110-4ED21-0AA0 3VA5110-5ED21-0AA0 3VA5110-6ED21-0AA0 technology separately for field
110 3VA5111-4ED21-0AA0 3VA5111-5ED21-0AA0 3VA5111-6ED21-0AA0 installation.
125 3VA5112-4ED21-0AA0 3VA5112-5ED21-0AA0 3VA5112-6ED21-0AA0
All 3VA51 thermal-magnetic trip
circuit breakers are UL listed for
Dimensions Shipping Weight reverse feed applications.
Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg For NAVAL-rated thermal-magnetic
3VA51 1 1 (25.4) 5.5 (140) 3 (76.5) 0.84 0.38 trip circuit breakers, change the 13th
3VA51 2 2 (50.8) 5.5 (140) 3 (76.5) 1.37 0.62 digit of the catalog number to the
3VA51 3 3 (76.2) 5.5 (140) 3 (76.5) 1.73 0.78 number "1". (For example, a 35KA
3VA51 4 4 (101.6) 5.5 (140) 3 (76.5) 2.09 0.95 @480VAC, 40A, 3-pole, NAVAL rated
3VA51 would be catalog number
3VA5140-5ED31-1AA0)

a Available with NAVAL/50C ratings.

7-46 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/28/19
3VA Molded Case Circuit Breakers
3VA51 125A Thermal-magnetic Trip Circuit Breakers Selection

3VA51 125A Frame, 3-Pole Thermal-Magnetic Trip Unit


S-Interrupting Class M-Interrupting Class H-Interrupting Class
Cont.
(SEAS) (MEAS) (HEAS)
Ampere
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFMa
15 3VA5195-4ED31-0AA0 3VA5195-5ED31-0AA0 3VA5195-6ED31-0AA0
20 3VA5120-4ED31-0AA0 3VA5120-5ED31-0AA0 3VA5120-6ED31-0AA0
25 3VA5125-4ED31-0AA0 3VA5125-5ED31-0AA0 3VA5125-6ED31-0AA0
30 3VA5130-4ED31-0AA0 3VA5130-5ED31-0AA0 3VA5130-6ED31-0AA0
35 3VA5135-4ED31-0AA0 3VA5135-5ED31-0AA0 3VA5135-6ED31-0AA0
40 3VA5140-4ED31-0AA0 3VA5140-5ED31-0AA0 3VA5140-6ED31-0AA0
45 3VA5145-4ED31-0AA0 3VA5145-5ED31-0AA0 3VA5145-6ED31-0AA0
50 3VA5150-4ED31-0AA0 3VA5150-5ED31-0AA0 3VA5150-6ED31-0AA0
3VA51 125A 3-Pole
60 3VA5160-4ED31-0AA0 3VA5160-5ED31-0AA0 3VA5160-6ED31-0AA0
70 3VA5170-4ED31-0AA0 3VA5170-5ED31-0AA0 3VA5170-6ED31-0AA0
80 3VA5180-4ED31-0AA0 3VA5180-5ED31-0AA0 3VA5180-6ED31-0AA0
Ordering Information
90 3VA5190-4ED31-0AA0 3VA5190-5ED31-0AA0 3VA5190-6ED31-0AA0
100 3VA5110-4ED31-0AA0 3VA5110-5ED31-0AA0 3VA5110-6ED31-0AA0 The catalog numbers listed here are
110 3VA5111-4ED31-0AA0 3VA5111-5ED31-0AA0 3VA5111-6ED31-0AA0 for complete, non-interchangable trip
125 3VA5112-4ED31-0AA0 3VA5112-5ED31-0AA0 3VA5112-6ED31-0AA0 circuit breakers without lugs.
TM230 FTAMa
Order required lugs or connection
15 3VA5195-4EC31-0AA0 3VA5195-6EC31-0AA0 3VA5195-6EC31-0AA0
technology separately for field
20 3VA5120-4EC31-0AA0 3VA5120-5EC31-0AA0 3VA5120-6EC31-0AA0
installation.
25 3VA5125-4EC31-0AA0 3VA5125-5EC31-0AA0 3VA5125-6EC31-0AA0
30 3VA5130-4EC31-0AA0 3VA5130-5EC31-0AA0 3VA5130-6EC31-0AA0 All 3VA51 thermal-magnetic trip
35 3VA5135-4EC31-0AA0 3VA5135-5EC31-0AA0 3VA5135-6EC31-0AA0 circuit breakers are UL listed for
40 3VA5140-4EC31-0AA0 3VA5140-5EC31-0AA0 3VA5140-6EC31-0AA0 reverse feed applications.
45 3VA5145-4EC31-0AA0 3VA5145-5EC31-0AA0 3VA5145-6EC31-0AA0 For NAVAL-rated thermal-magnetic
50 3VA5150-4EC31-0AA0 3VA5150-5EC31-0AA0 3VA5150-6EC31-0AA0 trip circuit breakers, change the 13th
60 3VA5160-4EC31-0AA0 3VA5160-5EC31-0AA0 3VA5160-6EC31-0AA0 digit of the catalog number to the
70 3VA5170-4EC31-0AA0 3VA5170-5EC31-0AA0 3VA5170-6EC31-0AA0 number "1". (For example, a 35KA
80 3VA5180-4EC31-0AA0 3VA5180-5EC31-0AA0 3VA5180-6EC31-0AA0 @480VAC, 40A, 3-pole, NAVAL rated
90 3VA5190-4EC31-0AA0 3VA5190-5EC31-0AA0 3VA5190-6EC31-0AA0 3VA51 would be catalog number
100 3VA5110-4EC31-0AA0 3VA5110-5EC31-0AA0 3VA5110-6EC31-0AA0 3VA5140-5ED31-1AA0)
110 3VA5111-4EC31-0AA0 3VA5111-5EC31-0AA0 3VA5111-6EC31-0AA0

7
125 3VA5112-4EC31-0AA0 3VA5112-5EC31-0AA0 3VA5112-6EC31-0AA0
TM240 ATAM Enclosures (3-pole only)

CIRCUIT BREAKERS
MOLDED CASE
15 3VA5195-4EF31-0AA0 3VA5195-5EF31-0AA0 3VA5195-6EF31-0AA0 Nema Type Catalog Number
20 3VA5120-4EF31-0AA0 3VA5120-5EF31-0AA0 3VA5120-6EF31-0AA0 1 surface 3VAE125N1S
30 3VA5130-4EF31-0AA0 3VA5130-5EF31-0AA0 3VA5130-6EF31-0AA0 1 flush 3VAE125N1F
40 3VA5140-4EF31-0AA0 3VA5140-5EF31-0AA0 3VA5140-6EF31-0AA0 3R 3VAE125N3R
50 3VA5150-4EF31-0AA0 3VA5150-5EF31-0AA0 3VA5150-6EF31-0AA0 12 3VAE125N12
60 3VA5160-4EF31-0AA0 3VA5160-5EF31-0AA0 3VA5160-6EF31-0AA0 4X (304) 3VAE125N4X
70 3VA5170-4EF31-0AA0 3VA5170-5EF31-0AA0 3VA5170-6EF31-0AA0 4X (316) 3VAE125N4X316
80 3VA5180-4EF31-0AA0 3VA5180-5EF31-0AA0 3VA5180-6EF31-0AA0 Neutral N250X
100 3VA5110-4EF31-0AA0 3VA5110-5EF31-0AA0 3VA5110-6EF31-0AA0 200% Neutral N2250X

Dimensions Shipping Weight


Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg
3VA51 1 1 (25.4) 5.5 (140) 3 (76.5) 0.84 0.38
3VA51 2 2 (50.8) 5.5 (140) 3 (76.5) 1.37 0.62
3VA51 3 3 (76.2) 5.5 (140) 3 (76.5) 1.73 0.78
3VA51 4 4 (101.6) 5.5 (140) 3 (76.5) 2.09 0.95

a Available with NAVAL/50C ratings.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-47


Revised on 02/28/19

3VA Molded Case Circuit Breakers


3VA51 125A Thermal-magnetic Trip Circuit Breakers Selection

3VA51 125A Frame, 4-Pole Thermal-Magnetic Trip Unit


S-Interrupting Class M-Interrupting Class H-Interrupting Class
Cont.
(SEAS) (MEAS) (HEAS)
Ampere
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFM Unprotected Neutral
15 3VA5195-4ED41-0AA0 3VA5195-5ED41-0AA0 3VA5195-6ED41-0AA0
20 3VA5120-4ED41-0AA0 3VA5120-5ED41-0AA0 3VA5120-6ED41-0AA0
25 3VA5125-4ED41-0AA0 3VA5125-5ED41-0AA0 3VA5125-6ED41-0AA0
30 3VA5130-4ED41-0AA0 3VA5130-5ED41-0AA0 3VA5130-6ED41-0AA0
35 3VA5135-4ED41-0AA0 3VA5135-5ED41-0AA0 3VA5135-6ED41-0AA0
40 3VA5140-4ED41-0AA0 3VA5140-5ED41-0AA0 3VA5140-6ED41-0AA0
45 3VA5145-4ED41-0AA0 3VA5145-5ED41-0AA0 3VA5145-6ED41-0AA0
50 3VA5150-4ED41-0AA0 3VA5150-5ED41-0AA0 3VA5150-6ED41-0AA0
60 3VA5160-4ED41-0AA0 3VA5160-5ED41-0AA0 3VA5160-6ED41-0AA0
70 3VA5170-4ED41-0AA0 3VA5170-5ED41-0AA0 3VA5170-6ED41-0AA0
80 3VA5180-4ED41-0AA0 3VA5180-5ED41-0AA0 3VA5180-6ED41-0AA0
90 3VA5190-4ED41-0AA0 3VA5190-5ED41-0AA0 3VA5190-6ED41-0AA0
3VA51 125A 4-Pole
100 3VA5110-4ED41-0AA0 3VA5110-5ED41-0AA0 3VA5110-6ED41-0AA0
110 3VA5111-4ED41-0AA0 3VA5111-5ED41-0AA0 3VA5111-6ED41-0AA0
Ordering Information
125 3VA5112-4ED41-0AA0 3VA5112-5ED41-0AA0 3VA5112-6ED41-0AA0
TM210 FTFM 100% Neutral The catalog numbers listed here are
90 3VA5190-4GD41-0AA0 3VA5190-5GD41-0AA0 3VA5190-6GD41-0AA0 for complete, non-interchangable trip
100 3VA5110-4GD41-0AA0 3VA5110-5GD41-0AA0 3VA5110-6GD41-0AA0 circuit breakers without lugs.
110 3VA5111-4GD41-0AA0 3VA5111-5GD41-0AA0 3VA5111-6GD41-0AA0 Order required lugs or connection
125 3VA5112-4GD41-0AA0 3VA5112-5GD41-0AA0 3VA5112-6GD41-0AA0 technology separately for field
TM230 FTAM Unprotected Neutral installation.
15 3VA5195-4EC41-0AA0 3VA5195-5EC41-0AA0 3VA5195-6EC41-0AA0 All 3VA51 thermal-magnetic trip
20 3VA5120-4EC41-0AA0 3VA5120-5EC41-0AA0 3VA5120-6EC41-0AA0 circuit breakers are UL listed for
25 3VA5125-4EC41-0AA0 3VA5125-5EC41-0AA0 3VA5125-6EC41-0AA0 reverse feed applications.
30 3VA5130-4EC41-0AA0 3VA5130-5EC41-0AA0 3VA5130-6EC41-0AA0
35 3VA5135-4EC41-0AA0 3VA5135-5EC41-0AA0 3VA5135-6EC41-0AA0
For NAVAL-rated thermal-magnetic
40 3VA5140-4EC41-0AA0 3VA5140-5EC41-0AA0 3VA5140-6EC41-0AA0
trip circuit breakers, change the 13th
45 3VA5145-4EC41-0AA0 3VA5145-5EC41-0AA0 3VA5145-6EC41-0AA0
digit of the catalog number to the
50 3VA5150-4EC41-0AA0 3VA5150-5EC41-0AA0 3VA5150-6EC41-0AA0
number "1". (For example, a 35KA
60 3VA5160-4EC41-0AA0 3VA5160-5EC41-0AA0 3VA5160-6EC41-0AA0
@480VAC, 40A, 3-pole, NAVAL rated
7

70 3VA5170-4EC41-0AA0 3VA5170-5EC41-0AA0 3VA5170-6EC41-0AA0


3VA51 would be catalog number
80 3VA5180-4EC41-0AA0 3VA5180-5EC41-0AA0 3VA5180-6EC41-0AA0
3VA5140-5ED31-1AA0)
MOLDED CASE
CIRCUIT BREAKERS

90 3VA5190-4EC41-0AA0 3VA5190-5EC41-0AA0 3VA5190-6EC41-0AA0


100 3VA5110-4EC41-0AA0 3VA5110-5EC41-0AA0 3VA5110-6EC41-0AA0
110 3VA5111-4EC41-0AA0 3VA5111-5EC41-0AA0 3VA5111-6EC41-0AA0
125 3VA5112-4EC41-0AA0 3VA5112-5EC41-0AA0 3VA5112-6EC41-0AA0
TM230 FTFM 100% Neutral
90 3VA5190-4GC41-0AA0 3VA5190-5GC41-0AA0 3VA5190-6GC41-0AA0
100 3VA5110-4GC41-0AA0 3VA5110-5GC41-0AA0 3VA5110-6GC41-0AA0
110 3VA5111-4GC41-0AA0 3VA5111-5GC41-0AA0 3VA5111-6GC41-0AA0
125 3VA5112-4GC41-0AA0 3VA5112-5GC41-0AA0 3VA5112-6GC41-0AA0
TM240 ATAM Unprotected Neutral
15 3VA5195-4EF41-0AA0 3VA5195-5EF41-0AA0 3VA5195-6EF41-0AA0
20 3VA5120-4EF41-0AA0 3VA5120-5EF41-0AA0 3VA5120-6EF41-0AA0
30 3VA5130-4EF41-0AA0 3VA5130-5EF41-0AA0 3VA5130-6EF41-0AA0
40 3VA5140-4EF41-0AA0 3VA5140-5EF41-0AA0 3VA5140-6EF41-0AA0
50 3VA5150-4EF41-0AA0 3VA5150-5EF41-0AA0 3VA5150-6EF41-0AA0
60 3VA5160-4EF41-0AA0 3VA5160-5EF41-0AA0 3VA5160-6EF41-0AA0
70 3VA5170-4EF41-0AA0 3VA5170-5EF41-0AA0 3VA5170-6EF41-0AA0
80 3VA5180-4EF41-0AA0 3VA5180-5EF41-0AA0 3VA5180-6EF41-0AA0
100 3VA5110-4EF41-0AA0 3VA5110-5EF41-0AA0 3VA5110-6EF41-0AA0
TM240 ATAM 100% Neutral
100 3VA5110-4GF41-0AA0 3VA5110-5GF41-0AA0 3VA5110-6GF41-0AA0

7-48 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/19

3VA Molded Case Circuit Breakers


3VA51 125A Thermal-magnetic Trip Circuit Breakers Technical information

Interrupting Ratings for 3VA51


RMS Symmetrical Amperes (kA)
Interrupting Breaker Volts AC (50/60 Hz) Volts DC
Class Type 120 240 277 347 480Y/277V 480 600Y/347V 125 250 500a 600a
1 65 25 14 14
S SEAS
2, 3, 4 65 25 25 14 14 50 50 50
1 85 35 18 25
M MEAS
2, 3, 4 85 35 35 18 25 85 85 85
1 150 50 18 30
H HEAS
2, 3, 4 150 65 65 25 30 100 100 100
a Applies to 3VA51 3-Pole

Trip Settings for 3VA51


TM210 - FTFM TM230 - FTAM TM240 - ATAM
In (A) Ir (A) Ii (A) In (A) Ir (A) Ii (A) In (A)
Ir (A) Ii (A)
15 15 300 15 15 150 180 210 240 270 300 15
12 150 180 210 240 270 300
20 20 300 20 20 150 180 210 240 270 300 20
16 150 180 210 240 270 300
25 25 300 25 25 150 180 210 240 270 300 30
24 150 180 210 240 270 300
30 30 300 30 30 150 180 210 240 270 300 40
32 200 240 280 320 360 400
35 35 350 35 35 175 210 245 280 315 350 50
40 250 300 350 400 450 500
40 40 400 40 40 200 240 280 320 360 400 60
48 300 360 420 480 540 600
45 45 450 45 45 225 270 315 360 405 450 70
56 350 420 490 560 630 700
50 50 500 50 50 250 300 350 400 450 500 80
64 400 480 560 640 720 800
60 60 600 60 60 300 360 420 480 540 600 100
80 500 600 700 800 900 1000
70 70 700 70 70 350 420 490 560 630 700
80 80 800 80 80 400 480 560 640 720 3VA
800UL Molded Case Circuit Breakers
90 90 900 90 90 450 540 630 720 810 900
Accessories and Spare Parts
100 100 1000 100 100 500 600 700 800 900 1000
110 110 1100 110 110 550 660 770 880 990 Internal
1100 accessories
125 125 1250 125 125 625 750 875 1000 1125 1250
Design

Connectors for 75C Wire for 3VA51


Internal accessories configuration 3VA4/3VA5 3VA5
Min. Max. 125 A 125 A
cable cable Catalog No. Catalog No. 1 in 2-pole 3 & 4-pole
Type size size (kit of 3 lugs) (kit of 4 lugs) /2-pole

7
Steel wrap around (Cu AWG
3/0 3VA9133-0JA11 3VA9134-0JA11
cable only), 1 cable lugs 14

CIRCUIT BREAKERS
MOLDED CASE
Aluminum body lug small AWG AWG
3VA9133-0JB10 3VA9134-0JB10 125 A 125 A
(Cu/Al cable), 1 cable lug 14 10
Aluminum body lug (Cu/Al AWG Slot No.: 23 22 21 23 22 21 11 12 13
3/0 3VA9133-0JB11 3VA9134-0JB11
cable), 1 cable lugs 14 Auxiliary switch Type
Aluminum body lug small AUX_HQ x x x x x x x x x
AWG AWG
with control wire tap (Cu/Al 3VA9133-0JG10 3VA9134-0JG10 AUX_HQ_el x x x x x x x x x
14 10 Auxiliary switch
cable), 1 cable lug x x x
Aluminum body lug with AUX_HP
AWG x x x
control wire tap (Cu/Al 3/0 3VA9133-0JG11 3VA9134-0JG11
14 LCS_HQ x
cable), 1 cable lugs Leading
Aluminum body lug large (Cu/ LCS_HQ_el x
changeover switch
AWG 300
Al cable), 1 cable lugs with 1 3VA9133-0JJ12 LCS_HP x
4 kcmil
extended terminal cover Alarm switch Type
Aluminum body lug large TAS_HQ x x x x x x
with control wire tap (Cu/Al AWG 300
3VA9133-0JC12 Trip alarm switch TAS_HQ_el x x x x x x
cable), 1 cable lug and 4 kcmil
1 extended terminal cover TAS_HP x x x
Distribution lug, 6 cables (Cu/ SAS_HQ
AWG AWG Short circuit alarm switch
Al cable), 1 cable lugs with 3VA9133-0JF60 3VA9134-0JF60 SAS_HQ_el
14 2
1 extended terminal cover
Auxiliary release Type
Copper body lug small (Cu AWG AWG
3VA9133-0JD10 3VA9134-0JD10
cable only), 1 cable lugs 14 10 4 Shunt trip flexible STF
STL
x
x
x
x
Copper body lug (Cu cable AWG Shunt trip left
2/0 3VA9133-0JD11 3VA9134-0JD11 STL_el
only), 1 cable lugs 14
Copper body lug small with Residual current release RCR
AWG AWG
control wire tap (Cu cable 3VA9133-0JK10 3VA9134-0JK10 Undervoltage release UVR x x
14 10
only), 1 cable lugs Universal release UNI x x
Copper body lug with Other
AWG
control wire tap (Cu cable 2/0 3VA9133-0JK11 3VA9134-0JK11
14 Cylinder lock (type Ronis) x
only), 1 cable lugs

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-49


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA61 150A Electronic Trip Circuit Breakers Selection

Ordering Information
The catalog numbers listed below are for complete, non-interchangable
trip circuit breakers without lugs.
Order required lugs or connection technology separately for field installation.
All 3VA61 electronict trip circuit breakers are UL listed for reverse feed applications.
All 3VA61 electronic trip circuit breakers are available with 100% ratings.
For 100% rated electronic trip circuit breakers, change the 13th digit of the
catalog number to the number "2". (For example, a 35KA @480VAC, 40A,
3-pole, 100% rated 3VA61 would be catalog number 3VA6140-5HL31-2AA0)
Requires the use of rated lugs — see lug table below.
All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked
3VA61 150A 3-Pole “Naval”, and are suitable for use at 50C.

3VA61 150A Frame 3-Pole Electronic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class L-Interrupting Class E-Interrupting Class
Continuous (MDAE) (HDAE) (CDAE) (LDAE) (EDAE)
Ampere Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
ETU320 LI with dials
40 3VA6140-5HL31-0AA0 3VA6140-6HL31-0AA0 3VA6140-7HL31-0AA0 3VA6140-8HL31-0AA0 3VA6160-0HL31-0AA0a
100 3VA6110-5HL31-0AA0 3VA6110-6HL31-0AA0 3VA6110-7HL31-0AA0 3VA6110-8HL31-0AA0 3VA6110-0HL31-0AA0
150 3VA6115-5HL31-0AA0 3VA6115-6HL31-0AA0 3VA6115-7HL31-0AA0 3VA6115-8HL31-0AA0 3VA6115-0HL31-0AA0
ETU330 LIG with dials
40 3VA6140-5HM31-0AA0 3VA6140-6HM31-0AA0 3VA6140-7HM31-0AA0 3VA6140-8HM31-0AA0 3VA6160-0HM31-0AA0a
100 3VA6110-5HM31-0AA0 3VA6110-6HM31-0AA0 3VA6110-7HM31-0AA0 3VA6110-8HM31-0AA0 3VA6110-0HM31-0AA0
150 3VA6115-5HM31-0AA0 3VA6115-6HM31-0AA0 3VA6115-7HM31-0AA0 3VA6115-8HM31-0AA0 3VA6115-0HM31-0AA0
ETU350 LSI with dials
40 3VA6140-5HN31-0AA0 3VA6140-6HN31-0AA0 3VA6140-7HN31-0AA0 3VA6140-8HN31-0AA0 3VA6160-0HN31-0AA0a
100 3VA6110-5HN31-0AA0 3VA6110-6HN31-0AA0 3VA6110-7HN31-0AA0 3VA6110-8HN31-0AA0 3VA6110-0HN31-0AA0
150 3VA6115-5HN31-0AA0 3VA6115-6HN31-0AA0 3VA6115-7HN31-0AA0 3VA6115-8HN31-0AA0 3VA6115-0HN31-0AA0
ETU550 LSI with LCD
40 3VA6140-5JP31-0AA0 3VA6140-6JP31-0AA0 3VA6140-7JP31-0AA0 3VA6140-8JP31-0AA0 —
100 3VA6110-5JP31-0AA0 3VA6110-6JP31-0AA0 3VA6110-7JP31-0AA0 3VA6110-8JP31-0AA0 —
150 3VA6115-5JP31-0AA0 3VA6115-6JP31-0AA0 3VA6115-7JP31-0AA0 3VA6115-8JP31-0AA0 —
ETU556 LSI(G Alarm) with LCD
7

40 3VA6140-5JT31-0AA0 3VA6140-6JT31-0AA0 3VA6140-7JT31-0AA0 3VA6140-8JT31-0AA0 —


100 3VA6110-5JT31-0AA0 3VA6110-6JT31-0AA0 3VA6110-7JT31-0AA0 3VA6110-8JT31-0AA0 —
MOLDED CASE
CIRCUIT BREAKERS

150 3VA6115-5JT31-0AA0 3VA6115-6JT31-0AA0 3VA6115-7JT31-0AA0 3VA6115-8JT31-0AA0 —


ETU560 LSIG with LCD
40 3VA6140-5JQ31-0AA0 3VA6140-6JQ31-0AA0 3VA6140-7JQ31-0AA0 3VA6140-8JQ31-0AA0 —
100 3VA6110-5JQ31-0AA0 3VA6110-6JQ31-0AA0 3VA6110-7JQ31-0AA0 3VA6110-8JQ31-0AA0 —
150 3VA6115-5JQ31-0AA0 3VA6115-6JQ31-0AA0 3VA6115-7JQ31-0AA0 3VA6115-8JQ31-0AA0 —
ETU820 LI LCD with Metering
40 3VA6140-5KL31-0AA0 3VA6140-6KL31-0AA0 3VA6140-7KL31-0AA0 3VA6140-8KL31-0AA0 —
100 3VA6110-5KL31-0AA0 3VA6110-6KL31-0AA0 3VA6110-7KL31-0AA0 3VA6110-8KL31-0AA0 —
150 3VA6115-5KL31-0AA0 3VA6115-6KL31-0AA0 3VA6115-7KL31-0AA0 3VA6115-8KL31-0AA0 —
ETU830 LIG with LCD and Metering
40 3VA6140-5KM31-0AA0 3VA6140-6KM31-0AA0 3VA6140-7KM31-0AA0 3VA6140-8KM31-0AA0 —
100 3VA6110-5KM31-0AA0 3VA6110-6KM31-0AA0 3VA6110-7KM31-0AA0 3VA6110-8KM31-0AA0 —
150 3VA6115-5KM31-0AA0 3VA6115-6KM31-0AA0 3VA6115-7KM31-0AA0 3VA6115-8KM31-0AA0 —
ETU850 LSI with LCD and Metering
40 3VA6140-5KP31-0AA0 3VA6140-6KP31-0AA0 3VA6140-7KP31-0AA0 3VA6140-8KP31-0AA0 —
100 3VA6110-5KP31-0AA0 3VA6110-6KP31-0AA0 3VA6110-7KP31-0AA0 3VA6110-8KP31-0AA0 —
150 3VA6115-5KP31-0AA0 3VA6115-6KP31-0AA0 3VA6115-7KP31-0AA0 3VA6115-8KP31-0AA0 —
ETU856 LSI(G Alarm) with LCD and Metering
40 3VA6140-5KT31-0AA0 3VA6140-6KT31-0AA0 3VA6140-7KT31-0AA0 3VA6140-8KT31-0AA0 3VA6160-0KT31-0AA0a
100 3VA6110-5KT31-0AA0 3VA6110-6KT31-0AA0 3VA6110-7KT31-0AA0 3VA6110-8KT31-0AA0 3VA6110-0KT31-0AA0
150 3VA6115-5KT31-0AA0 3VA6115-6KT31-0AA0 3VA6115-7KT31-0AA0 3VA6115-8KT31-0AA0 3VA6115-0KT31-0AA0
ETU860 LSIG with LCD and Metering
40 3VA6140-5KQ31-0AA0 3VA6140-6KQ31-0AA0 3VA6140-7KQ31-0AA0 3VA6140-8KQ31-0AA0 3VA6160-0KQ31-0AA0a
100 3VA6110-5KQ31-0AA0 3VA6110-6KQ31-0AA0 3VA6110-7KQ31-0AA0 3VA6110-8KQ31-0AA0 3VA6110-0KQ31-0AA0
150 3VA6115-5KQ31-0AA0 3VA6115-6KQ31-0AA0 3VA6115-7KQ31-0AA0 3VA6115-8KQ31-0AA0 3VA6115-0KQ31-0AA0
a The lowest amperage trip unit available for the EDAE class breakers is 60 amps.

7-50 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA61 150A Electronic Trip Circuit Breakers Selection

Ordering Information
The catalog numbers listed below are for complete, non-interchangable
trip circuit breakers without lugs.
Order required lugs or connection technology separately for field installation.
All 3VA61 electronict trip circuit breakers are UL listed for reverse feed applications.
All 3VA61 electronic trip circuit breakers are available with 100% ratings.
For 100% rated electronic trip circuit breakers, change the 13th digit of the
catalog number to the number "2". (For example, a 35KA @480VAC, 40A,
3-pole, 100% rated 3VA61 would be catalog number 3VA6140-5HL31-2AA0)
Requires the use of rated lugs — see lug table below.
All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked
3VA61 150A 4-Pole “Naval”, and are suitable for use at 50C.

3VA61 150A Frame 4-Pole Electronic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class L-Interrupting Class E-Interrupting Class
Continuous (MDAE) (HDAE) (CDAE) (LDAE) (EDAE)
Ampere Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
ETU320 LI with dials
40 3VA6140-5HL41-0AA0 3VA6140-6HL41-0AA0 3VA6140-7HL41-0AA0 3VA6140-8HL41-0AA0 3VA6160-0HL41-0AA0a
100 3VA6110-5HL41-0AA0 3VA6110-6HL41-0AA0 3VA6110-7HL41-0AA0 3VA6110-8HL41-0AA0 3VA6110-0HL41-0AA0
150 3VA6115-5HL41-0AA0 3VA6115-6HL41-0AA0 3VA6115-7HL41-0AA0 3VA6115-8HL41-0AA0 3VA6115-0HL41-0AA0
ETU330 LIG with dials
40 3VA6140-5HM41-0AA0 3VA6140-6HM41-0AA0 3VA6140-7HM41-0AA0 3VA6140-8HM41-0AA0 3VA6160-0HM41-0AA0a
100 3VA6110-5HM41-0AA0 3VA6110-6HM41-0AA0 3VA6110-7HM41-0AA0 3VA6110-8HM41-0AA0 3VA6110-0HM41-0AA0
150 3VA6115-5HM41-0AA0 3VA6115-6HM41-0AA0 3VA6115-7HM41-0AA0 3VA6115-8HM41-0AA0 3VA6115-0HM41-0AA0
ETU350 LSI with dials
40 3VA6140-5HN41-0AA0 3VA6140-6HN41-0AA0 3VA6140-7HN41-0AA0 3VA6140-8HN41-0AA0 3VA6160-0HN41-0AA0a
100 3VA6110-5HN41-0AA0 3VA6110-6HN41-0AA0 3VA6110-7HN41-0AA0 3VA6110-8HN41-0AA0 3VA6110-0HN41-0AA0
150 3VA6115-5HN41-0AA0 3VA6115-6HN41-0AA0 3VA6115-7HN41-0AA0 3VA6115-8HN41-0AA0 3VA6115-0HN41-0AA0
ETU550 LSI with LCD
40 3VA6140-5JP41-0AA0 3VA6140-6JP41-0AA0 3VA6140-7JP41-0AA0 3VA6140-8JP41-0AA0 —
100 3VA6110-5JP41-0AA0 3VA6110-6JP41-0AA0 3VA6110-7JP41-0AA0 3VA6110-8JP41-0AA0 —
150 3VA6115-5JP41-0AA0 3VA6115-6JP41-0AA0 3VA6115-7JP41-0AA0 3VA6115-8JP41-0AA0 —
ETU556 LSI(G Alarm) with LCD

7
40 3VA6140-5JT41-0AA0 3VA6140-6JT41-0AA0 3VA6140-7JT41-0AA0 3VA6140-8JT41-0AA0 —
100 3VA6110-5JT41-0AA0 3VA6110-6JT41-0AA0 3VA6110-7JT41-0AA0 3VA6110-8JT41-0AA0 —

CIRCUIT BREAKERS
MOLDED CASE
150 3VA6115-5JT41-0AA0 3VA6115-6JT41-0AA0 3VA6115-7JT41-0AA0 3VA6115-8JT41-0AA0 —
ETU560 LSIG with LCD
40 3VA6140-5JQ41-0AA0 3VA6140-6JQ41-0AA0 3VA6140-7JQ41-0AA0 3VA6140-8JQ41-0AA0 —
100 3VA6110-5JQ41-0AA0 3VA6110-6JQ41-0AA0 3VA6110-7JQ41-0AA0 3VA6110-8JQ41-0AA0 —
150 3VA6115-5JQ41-0AA0 3VA6115-6JQ41-0AA0 3VA6115-7JQ41-0AA0 3VA6115-8JQ41-0AA0 —
ETU820 LI LCD with Metering
40 3VA6140-5KL41-0AA0 3VA6140-6KL41-0AA0 3VA6140-7KL41-0AA0 3VA6140-8KL41-0AA0 —
100 3VA6110-5KL41-0AA0 3VA6110-6KL41-0AA0 3VA6110-7KL41-0AA0 3VA6110-8KL41-0AA0 —
150 3VA6115-5KL41-0AA0 3VA6115-6KL41-0AA0 3VA6115-7KL41-0AA0 3VA6115-8KL41-0AA0 —
ETU830 LIG with LCD and Metering
40 3VA6140-5KM41-0AA0 3VA6140-6KM41-0AA0 3VA6140-7KM41-0AA0 3VA6140-8KM41-0AA0 —
100 3VA6110-5KM41-0AA0 3VA6110-6KM41-0AA0 3VA6110-7KM41-0AA0 3VA6110-8KM41-0AA0 —
150 3VA6115-5KM41-0AA0 3VA6115-6KM41-0AA0 3VA6115-7KM41-0AA0 3VA6115-8KM41-0AA0 —
ETU850 LSI with LCD and Metering
40 3VA6140-5KP41-0AA0 3VA6140-6KP41-0AA0 3VA6140-7KP41-0AA0 3VA6140-8KP41-0AA0 —
100 3VA6110-5KP41-0AA0 3VA6110-6KP41-0AA0 3VA6110-7KP41-0AA0 3VA6110-8KP41-0AA0 —
150 3VA6115-5KP41-0AA0 3VA6115-6KP41-0AA0 3VA6115-7KP41-0AA0 3VA6115-8KP41-0AA0 —
ETU856 LSI(G Alarm) with LCD and Metering
40 3VA6140-5KT41-0AA0 3VA6140-6KT41-0AA0 3VA6140-7KT41-0AA0 3VA6140-8KT41-0AA0 3VA6160-0KT41-0AA0a
100 3VA6110-5KT41-0AA0 3VA6110-6KT41-0AA0 3VA6110-7KT41-0AA0 3VA6110-8KT41-0AA0 3VA6110-0KT41-0AA0
150 3VA6115-5KT41-0AA0 3VA6115-6KT41-0AA0 3VA6115-7KT41-0AA0 3VA6115-8KT41-0AA0 3VA6115-0KT41-0AA0
ETU860 LSIG with LCD and Metering
40 3VA6140-5KQ41-0AA0 3VA6140-6KQ41-0AA0 3VA6140-7KQ41-0AA0 3VA6140-8KQ41-0AA0 3VA6160-0KQ41-0AA0a
100 3VA6110-5KQ41-0AA0 3VA6110-6KQ41-0AA0 3VA6110-7KQ41-0AA0 3VA6110-8KQ41-0AA0 3VA6110-0KQ41-0AA0
150 3VA6115-5KQ41-0AA0 3VA6115-6KQ41-0AA0 3VA6115-7KQ41-0AA0 3VA6115-8KQ41-0AA0 3VA6115-0KQ41-0AA0
a The lowest amperage trip unit available for the EDAE class breakers is 60 amps.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-51


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA61 150A Electronic Trip Circuit Breakers Technical information

Connectors for 75C wire for 3VA61


Minimum Maximum Part Number Part Number
Type cable size cable size (kit of 3 lugs) (kit of 4 lugs)
Steel Wrap around (Cu cable only) AWG 10 3/0 3VA9143-0JA12 3VA9144-0JA12
single cable lugsb AWG 4 350 kcmil 3VA9243-0JA12 3VA9244-0JA12
Aluminum Body Lug (Cu/Al cable) AWG 14 1/0 3VA9143-0JB11 3VA9144-0JB11
single cable lugsa AWG 6 350 kcmil 3VA9243-0JB12 3VA9244-0JB12
Aluminum body lug with control wire tap AWG 14 1/0 3VA9143-0JG11c 3VA9144-0JG11c
(Cu/Al cable) single cable lugsa AWG 6 350 kcmil 3VA9243-0JG12 3VA9244-0JG12
Aluminum body lug large (Cu/Al cable)
AWG 2 350 kcmil 3VA9243-0JJ13 3VA9244-0JJ13
single cable lugs and 1 ext’d terminal covera
Aluminum body lug large with control wire tap
(Cu/Al cable) single cable lugs and AWG 2 350 kcmil 3VA9243-0JC13 3VA9244-0JC13
1 extended terminal covera
Aluminum body lug, 2 cables (Cu/Al cable) with
AWG 4 300 kcmil 3VA9243-0JJ22 3VA9244-0JJ22
1 extended terminal covera
Aluminum body lug, 2 cables (Cu/Al cable)
AWG 4 300 kcmil 3VA9243-0JC22 3VA9244-0JC22
with control wire tap and 1 extended terminal covera
Distribution lug, 6 Cables (Cu/Al cable) with
AWG 14 AWG 2 3VA9243-0JF60 3VA9244-0JF60
1 extended terminal coverb
Copper body lug (Cu cable only) single cable lugs AWG 14 1/0 3VA9143-0JD11 3VA9144-0JD11
kit of 3 single lugsa AWG 6 350 kcmil 3VA9243-0JD12 3VA9244-0JD12
Copper body lug (Cu cable only) with control AWG 14 1/0 3VA9143-0JK11c 3VA9144-0JK11c
wire tap single cable lugsa AWG 6 350 kcmil 3VA9243-0JK12 3VA9244-0JK12

Interrupting Ratings for 3VA61 Enclosures (3-pole only)


RMS Symmetrical Amperes (kA) Nema Type Catalog Number
Interrupting Breaker Volts AC (50/60 Hz) 1 surface 3VAE250N1S
Class Type 240 480Y/277V 480 600 1 flush 3VAE250N1F
M MDAE 100 35 35 18 3R 3VAE250N3R
H HDAE 100 65 65 22 12 3VAE250N12
C CDAE 200 100 100 35 4X (304) 3VAE250N4X
L LDAE 200 150 150 50 4X (316) 3VAE250N4X316
Neutral N250X
200% Neutral N2250X
Dimensions Shipping Weight
7

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg


3VA61 3 4.1 (105) 7.8 (198) 3.4 (86) 5.5 2.5
MOLDED CASE
CIRCUIT BREAKERS

3VA61 4 5.5 (140) 7.8 (198) 3.4 (86) 7.1 3.2

a Meets requirements for 100% rated breakers up to 150A.


b Meets requirements for 100% rated breakers up to 100A.
c Limited to 150A including the control wire tap.

7-52 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 09/30/19

3VA Molded Case Circuit Breakers


3VA61 150A Electronic Trip Circuit Breakers Technical information

Trip Settings for 3VA61


ETU320-LI, ETU330-LIG, ETU350-LSI
Continuous LI, LIG, LSI
Amperage LI, LIG, LSI LSI LIG 4P only
Isd= xIr
In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I)a (Amp) (S) tsd (sec) (S) Ig (Amp) (G) IN=xIr (Amp)
40 15 - 40 0.5 - 17 60-480 1.5 - 10 0.08 - 0.4 15 - 40 1 / OFF
100 40 - 100 0.5 - 17 150-1200 1.5 - 10 20 - 100 0.5 - 1 / OFF
150 60 - 150 0.5 - 17 225-1500 1.5 - 10 30 - 150 0.5 - 1 / OFF
a Ii for ETU350 is fixed at the maximum level shown in table.

ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG
Continuous LSI 3P with LI, LIG, LSI, LSIG,
Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) External CT LSI(G) 4P only
In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp)
40 15 - 40 0.5 - 25 60-480 24 - 400 0.05 - 0.5 15 - 40 0.05 - 0.8 15 - 64 / OFF 15 - 64 / OFF
100 40 - 100 0.5 - 25 150-1200 60 - 1000 20 - 100 20 - 160 / OFF 20 - 150 / OFF
150 60 - 150 0.5 - 20 225-1500 90 - 1500 30 - 150 30 - 240 / OFF 30 - 150 / OFF

For specific trip settings refer to the Electronic Trip Unit section3VA
of the
UL3VA Systems
Molded Manual,
Case Circuit Breakers
which can be found in the document download center at https://www.siemens.com/download?BTLV_50412.
Accessories and Spare Parts
Internal accessories
Internal accessories 3VA6 3VA6
Optional equipment 150/250 A 150/250 A
3-pole 4-pole

250 A 250 A

Slot No.: 24 23 22 21 11 12 13 14 34 33 32 31 24 23 22 21 11 12 13 14
Auxiliary switch Type
AUX_HQ x x x x x x x x x x x x x x x x x x x x
AUX_HQ_el x x x x x x x x x x x x x x x x x x x x
Auxiliary switch
AUX_HP x x x x x x x x x x
x x x x x
LCS_HQ x x

7
Leading changeover switch LCS_HQ_el x x
LCS_HP x x

CIRCUIT BREAKERS
MOLDED CASE
Alarm switch Type
TAS_HQ x x x x x x x x
Trip alarm switch TAS_HQ_el x x x x x x x x
TAS_HP x x x x
EAS_HQ x x
Electrical alarm switch
EAS_HQ_el x x
Auxiliary release Type

Shunt trip flexible STF x x x x

Shunt trip left STL x x


4
Undervoltage release UVR x x
Universal release UNI x x
ETU/communication Type
Communication module COM060
x x
Breaker data server
24 V module x x
Other
Cylinder lock (type Ronis) x x
I201_19495

See page 7-73 for internal accessory


part numbers.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-53


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA52 250A Thermal-magnetic Trip Circuit Breakers Selection

3VA52 250 A, 2-Pole in 3-Pole Frame Thermal-Magnetic Trip Unit


Cont. M-Interrupting Class H-Interrupting Class C-Interrupting Class
Ampere (MFAS) (HFAS) (CFAS)
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFM
40 3VA5240-5ED61-0AA0 3VA5240-6ED61-0AA0 3VA5240-7ED61-0AA0
45 3VA5245-5ED61-0AA0 3VA5245-6ED61-0AA0 3VA5245-7ED61-0AA0
50 3VA5250-5ED61-0AA0 3VA5250-6ED61-0AA0 3VA5250-7ED61-0AA0
60 3VA5260-5ED61-0AA0 3VA5260-6ED61-0AA0 3VA5260-7ED61-0AA0
70 3VA5270-5ED61-0AA0 3VA5270-6ED61-0AA0 3VA5270-7ED61-0AA0
80 3VA5280-5ED61-0AA0 3VA5280-6ED61-0AA0 3VA5280-7ED61-0AA0
90 3VA5290-5ED61-0AA0 3VA5290-6ED61-0AA0 3VA5290-7ED61-0AA0
100 3VA5210-5ED61-0AA0 3VA5210-6ED61-0AA0 3VA5210-7ED61-0AA0
110 3VA5211-5ED61-0AA0 3VA5211-6ED61-0AA0 3VA5211-7ED61-0AA0
125 3VA5212-5ED61-0AA0 3VA5212-6ED61-0AA0 3VA5212-7ED61-0AA0
150 3VA5215-5ED61-0AA0 3VA5215-6ED61-0AA0 3VA5215-7ED61-0AA0 3VA52 250A 3-Pole
175 3VA5217-5ED61-0AA0 3VA5217-6ED61-0AA0 3VA5217-7ED61-0AA0
200 3VA5220-5ED61-0AA0 3VA5220-6ED61-0AA0 3VA5220-7ED61-0AA0
225 3VA5222-5ED61-0AA0 3VA5222-6ED61-0AA0 3VA5222-7ED61-0AA0 Ordering Information
250 3VA5225-5ED61-0AA0 3VA5225-6ED61-0AA0 3VA5225-7ED61-0AA0
TM230 FTAM The catalog numbers listed here are
70 3VA5270-5EC61-0AA0 3VA5270-6EC61-0AA0 3VA5270-7EC61-0AA0
for complete, non-interchangable trip
circuit breakers without lugs.
80 3VA5280-5EC61-0AA0 3VA5280-6EC61-0AA0 3VA5280-7EC61-0AA0
90 3VA5290-5EC61-0AA0 3VA5290-6EC61-0AA0 3VA5290-7EC61-0AA0 Order required lugs or connection
100 3VA5210-5EC61-0AA0 3VA5210-6EC61-0AA0 3VA5210-7EC61-0AA0
technology separately for field
installation.
110 3VA5211-5EC61-0AA0 3VA5211-6EC61-0AA0 3VA5211-7EC61-0AA0
125 3VA5212-5EC61-0AA0 3VA5212-6EC61-0AA0 3VA5212-7EC61-0AA0 All 3VA52 thermal-magnetic trip
150 3VA5215-5EC61-0AA0 3VA5215-6EC61-0AA0 3VA5215-7EC61-0AA0
circuit breakers are UL listed for
reverse feed applications.
175 3VA5217-5EC61-0AA0 3VA5217-6EC61-0AA0 3VA5217-7EC61-0AA0
200 3VA5220-5EC61-0AA0 3VA5220-6EC61-0AA0 3VA5220-7EC61-0AA0 For NAVAL rated thermal-magnetic
225 3VA5222-5EC61-0AA0 3VA5222-6EC61-0AA0 3VA5222-7EC61-0AA0 trip circuit breakers, change the 13th
digit of the catalog number to the
250 3VA5225-5EC61-0AA0 3VA5225-6EC61-0AA0 3VA5225-7EC61-0AA0
7

number "1". (For example, a 35KA


@480VAC, 150A, 3-pole, NAVAL
rated 3VA52 would be catalog
MOLDED CASE
CIRCUIT BREAKERS

Dimensions Shipping Weight


number 3VA5215-5ED31-1AA0)
Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg
3VA52 2(3-) pole 4.1 (105) 7.3 (185) 3.3 (83) 4.1 1.9
3VA52 3-pole 4.1 (105) 7.3 (185) 3.3 (83) 4.5 2.1
Enclosures (3-pole only)
Nema Type Catalog Number
1 surface 3VAE250N1S
1 flush 3VAE250N1F
3R 3VAE250N3R
12 3VAE250N12
4X (304) 3VAE250N4X
4X (316) 3VAE250N4X316
Neutral N250X
200% Neutral N2250X

7-54 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 07/31/19

3VA Molded Case Circuit Breakers


3VA52 250A Thermal-magnetic Trip Circuit Breakers Selection

3VA52 250 A Frame, 3-Pole Thermal-Magnetic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class
Cont.
(MFAS) (HFAS) (CFAS)
Ampere
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFMa
40 3VA5240-5ED31-0AA0 3VA5240-6ED31-0AA0 3VA5240-7ED31-0AA0
45 3VA5245-5ED31-0AA0 3VA5245-6ED31-0AA0 3VA5245-7ED31-0AA0
50 3VA5250-5ED31-0AA0 3VA5250-6ED31-0AA0 3VA5250-7ED31-0AA0
60 3VA5260-5ED31-0AA0 3VA5260-6ED31-0AA0 3VA5260-7ED31-0AA0
70 3VA5270-5ED31-0AA0 3VA5270-6ED31-0AA0 3VA5270-7ED31-0AA0
80 3VA5280-5ED31-0AA0 3VA5280-6ED31-0AA0 3VA5280-7ED31-0AA0
90 3VA5290-5ED31-0AA0 3VA5290-6ED31-0AA0 3VA5290-7ED31-0AA0
100 3VA5210-5ED31-0AA0 3VA5210-6ED31-0AA0 3VA5210-7ED31-0AA0
110 3VA5211-5ED31-0AA0 3VA5211-6ED31-0AA0 3VA5211-7ED31-0AA0
125 3VA5212-5ED31-0AA0 3VA5212-6ED31-0AA0 3VA5212-7ED31-0AA0
150 3VA5215-5ED31-0AA0 3VA5215-6ED31-0AA0 3VA5215-7ED31-0AA0
175 3VA5217-5ED31-0AA0 3VA5217-6ED31-0AA0 3VA5217-7ED31-0AA0
200 3VA5220-5ED31-0AA0 3VA5220-6ED31-0AA0 3VA5220-7ED31-0AA0
225 3VA5222-5ED31-0AA0 3VA5222-6ED31-0AA0 3VA5222-7ED31-0AA0 Ordering Information
250 3VA5225-5ED31-0AA0 3VA5225-6ED31-0AA0 3VA5225-7ED31-0AA0
The catalog numbers listed here are
TM230 FTAMa
for complete, non-interchangable trip
70 3VA5270-5EC31-0AA0 3VA5270-6EC31-0AA0 3VA5270-7EC31-0AA0
circuit breakers without lugs.
80 3VA5280-5EC31-0AA0 3VA5280-6EC31-0AA0 3VA5280-7EC31-0AA0
Order required lugs or connection
90 3VA5290-5EC31-0AA0 3VA5290-6EC31-0AA0 3VA5290-7EC31-0AA0
technology separately for field
100 3VA5210-5EC31-0AA0 3VA5210-6EC31-0AA0 3VA5210-7EC31-0AA0
installation.
110 3VA5211-5EC31-0AA0 3VA5211-6EC31-0AA0 3VA5211-7EC31-0AA0
All 3VA52 thermal-magnetic trip
125 3VA5212-5EC31-0AA0 3VA5212-6EC31-0AA0 3VA5212-7EC31-0AA0
circuit breakers are UL listed for
150 3VA5215-5EC31-0AA0 3VA5215-6EC31-0AA0 3VA5215-7EC31-0AA0
reverse feed applications.
175 3VA5217-5EC31-0AA0 3VA5217-6EC31-0AA0 3VA5217-7EC31-0AA0
For NAVAL rated thermal-magnetic
200 3VA5220-5EC31-0AA0 3VA5220-6EC31-0AA0 3VA5220-7EC31-0AA0
trip circuit breakers, change the 13th
225 3VA5222-5EC31-0AA0 3VA5222-6EC31-0AA0 3VA5222-7EC31-0AA0
digit of the catalog number to the

7
250 3VA5225-5EC31-0AA0 3VA5225-6EC31-0AA0 3VA5225-7EC31-0AA0 number "1". (For example, a 35KA
TM240 ATAM @480VAC, 150A, 3-pole, NAVAL
rated 3VA52 would be catalog

CIRCUIT BREAKERS
MOLDED CASE
70 3VA5270-5EF31-0AA0 3VA5270-6EF31-0AA0 3VA5270-7EF31-0AA0
80 3VA5280-5EF31-0AA0 3VA5280-6EF31-0AA0 3VA5280-7EF31-0AA0 number 3VA5215-5ED31-1AA0)
100 3VA5210-5EF31-0AA0 3VA5210-6EF31-0AA0 3VA5210-7EF31-0AA0
125 3VA5212-5EF31-0AA0 3VA5212-6EF31-0AA0 3VA5212-7EF31-0AA0
150 3VA5215-5EF31-0AA0 3VA5215-6EF31-0AA0 3VA5215-7EF31-0AA0 Enclosures (3-pole only)
175 3VA5217-5EF31-0AA0 3VA5217-6EF31-0AA0 3VA5217-7EF31-0AA0 Nema Type Catalog Number
200 3VA5220-5EF31-0AA0 3VA5220-6EF31-0AA0 3VA5220-7EF31-0AA0 1 surface 3VAE250N1S
250 3VA5225-5EF31-0AA0 3VA5225-6EF31-0AA0 3VA5225-7EF31-0AA0 1 flush 3VAE250N1F
3R 3VAE250N3R
12 3VAE250N12
Dimensions Shipping Weight 4X (304) 3VAE250N4X
Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg 4X (316) 3VAE250N4X316
3VA52 2(3-) pole 4.1 (105) 7.3 (185) 3.3 (83) 4.1 1.9 Neutral N250X
3VA52 3-pole 4.1 (105) 7.3 (185) 3.3 (83) 4.5 2.1 200% Neutral N2250X

a Available with NAVAL/50C ratings.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-55


Revised on 07/31/19

3VA Molded Case Circuit Breakers


3VA52 250A Thermal-magnetic Trip Circuit Breakers Selection

3VA52 250A Frame, 4-pole Thermal-Magnetic Trip Unit


Cont. M-Interrupting Class H-Interrupting Class C-Interrupting Class
Ampere (MFAS) (HFAS) (CFAS)
Rating Catalog Number Catalog Number Catalog Number
TM210 FTFM
40 3VA5240-5ED41-0AA0 3VA5240-6ED41-0AA0 3VA5240-7ED41-0AA0
45 3VA5245-5ED41-0AA0 3VA5245-6ED41-0AA0 3VA5245-7ED41-0AA0
50 3VA5250-5ED41-0AA0 3VA5250-6ED41-0AA0 3VA5250-7ED41-0AA0
60 3VA5260-5ED41-0AA0 3VA5260-6ED41-0AA0 3VA5260-7ED41-0AA0
70 3VA5270-5ED41-0AA0 3VA5270-6ED41-0AA0 3VA5270-7ED41-0AA0
80 3VA5280-5ED41-0AA0 3VA5280-6ED41-0AA0 3VA5280-7ED41-0AA0
90 3VA5290-5ED41-0AA0 3VA5290-6ED41-0AA0 3VA5290-7ED41-0AA0
100 3VA5210-5ED41-0AA0 3VA5210-6ED41-0AA0 3VA5210-7ED41-0AA0
110 3VA5211-5ED41-0AA0 3VA5211-6ED41-0AA0 3VA5211-7ED41-0AA0
125 3VA5212-5ED41-0AA0 3VA5212-6ED41-0AA0 3VA5212-7ED41-0AA0
150 3VA5215-5ED41-0AA0 3VA5215-6ED41-0AA0 3VA5215-7ED41-0AA0
175 3VA5217-5ED41-0AA0 3VA5217-6ED41-0AA0 3VA5217-7ED41-0AA0
200 3VA5220-5ED41-0AA0 3VA5220-6ED41-0AA0 3VA5220-7ED41-0AA0
225 3VA5222-5ED41-0AA0 3VA5222-6ED41-0AA0 3VA5222-7ED41-0AA0
250 3VA5225-5ED41-0AA0 3VA5225-6ED41-0AA0 3VA5225-7ED41-0AA0
TM210 FTFM 100% Neutral
90 3VA5290-5GD41-0AA0 3VA5290-6GD41-0AA0 3VA5290-7GD41-0AA0
100 3VA5210-5GD41-0AA0 3VA5210-6GD41-0AA0 3VA5210-7GD41-0AA0
110 3VA5211-5GD41-0AA0 3VA5211-6GD41-0AA0 3VA5211-7GD41-0AA0
125 3VA5212-5GD41-0AA0 3VA5212-6GD41-0AA0 3VA5212-7GD41-0AA0
150 3VA5215-5GD41-0AA0 3VA5215-6GD41-0AA0 3VA5215-7GD41-0AA0
175 3VA5217-5GD41-0AA0 3VA5217-6GD41-0AA0 3VA5217-7GD41-0AA0
200 3VA5220-5GD41-0AA0 3VA5220-6GD41-0AA0 3VA5220-7GD41-0AA0
225 3VA5222-5GD41-0AA0 3VA5222-6GD41-0AA0 3VA5222-7GD41-0AA0
250 3VA5225-5GD41-0AA0 3VA5225-6GD41-0AA0 3VA5225-7GD41-0AA0
TM230 FTAM
70 3VA5270-5EC41-0AA0 3VA5270-6EC41-0AA0 3VA5270-7EC41-0AA0
80 3VA5280-5EC41-0AA0 3VA5280-6EC41-0AA0 3VA5280-7EC41-0AA0
90 3VA5290-5EC41-0AA0 3VA5290-6EC41-0AA0 3VA5290-7EC41-0AA0
100 3VA5210-5EC41-0AA0 3VA5210-6EC41-0AA0 3VA5210-7EC41-0AA0
110 3VA5211-5EC41-0AA0 3VA5211-6EC41-0AA0 3VA5211-7EC41-0AA0
125 3VA5212-5EC41-0AA0 3VA5212-6EC41-0AA0 3VA5212-7EC41-0AA0
150 3VA5215-5EC41-0AA0 3VA5215-6EC41-0AA0 3VA5215-7EC41-0AA0
175 3VA5217-5EC41-0AA0 3VA5217-6EC41-0AA0 3VA5217-7EC41-0AA0
7

200 3VA5220-5EC41-0AA0 3VA5220-6EC41-0AA0 3VA5220-7EC41-0AA0


225 3VA5222-5EC41-0AA0 3VA5222-6EC41-0AA0 3VA5222-7EC41-0AA0
250 3VA5225-5EC41-0AA0 3VA5225-6EC41-0AA0 3VA5225-7EC41-0AA0
MOLDED CASE
CIRCUIT BREAKERS

TM230 FTAM 100% Neutral


90 3VA5290-5GC41-0AA0 3VA5290-6GC41-0AA0 3VA5290-7GC41-0AA0
100 3VA5210-5GC41-0AA0 3VA5210-6GC41-0AA0 3VA5210-7GC41-0AA0
110 3VA5211-5GC41-0AA0 3VA5211-6GC41-0AA0 3VA5211-7GC41-0AA0
125 3VA5212-5GC41-0AA0 3VA5212-6GC41-0AA0 3VA5212-7GC41-0AA0
150 3VA5215-5GC41-0AA0 3VA5215-6GC41-0AA0 3VA5215-7GC41-0AA0
175 3VA5217-5GC41-0AA0 3VA5217-6GC41-0AA0 3VA5217-7GC41-0AA0
200 3VA5220-5GC41-0AA0 3VA5220-6GC41-0AA0 3VA5220-7GC41-0AA0
225 3VA5222-5GC41-0AA0 3VA5222-6GC41-0AA0 3VA5222-7GC41-0AA0
250 3VA5225-5GC41-0AA0 3VA5225-6GC41-0AA0 3VA5225-7GC41-0AA0
TM240 ATAM
70 3VA5270-5EF41-0AA0 3VA5270-6EF41-0AA0 3VA5270-7EF41-0AA0
80 3VA5280-5EF41-0AA0 3VA5280-6EF41-0AA0 3VA5280-7EF41-0AA0
100 3VA5210-5EF41-0AA0 3VA5210-6EF41-0AA0 3VA5210-7EF41-0AA0
125 3VA5212-5EF41-0AA0 3VA5212-6EF41-0AA0 3VA5212-7EF41-0AA0
150 3VA5215-5EF41-0AA0 3VA5215-6EF41-0AA0 3VA5215-7EF41-0AA0
175 3VA5217-5EF41-0AA0 3VA5217-6EF41-0AA0 3VA5217-7EF41-0AA0
200 3VA5220-5EF41-0AA0 3VA5220-6EF41-0AA0 3VA5220-7EF41-0AA0
250 3VA5225-5EF41-0AA0 3VA5225-6EF41-0AA0 3VA5225-7EF41-0AA0
TM240 ATAM 100% Neutral
100 3VA5210-5GF41-0AA0 3VA5210-6GF41-0AA0 3VA5210-7GF41-0AA0
125 3VA5212-5GF41-0AA0 3VA5212-6GF41-0AA0 3VA5212-7GF41-0AA0
150 3VA5215-5GF41-0AA0 3VA5215-6GF41-0AA0 3VA5215-7GF41-0AA0
175 3VA5217-5GF41-0AA0 3VA5217-6GF41-0AA0 3VA5217-7GF41-0AA0
200 3VA5220-5GF41-0AA0 3VA5220-6GF41-0AA0 3VA5220-7GF41-0AA0
250 3VA5225-5GF41-0AA0 3VA5225-6GF41-0AA0 3VA5225-7GF41-0AA0

7-56 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/28/19

3VA Molded Case Circuit Breakers


3VA52 250A Thermal-magnetic Trip Circuit Breakers Technical information

Interrupting Ratings for 3VA52


RMS Symmetrical Amperes (kA)
Interrupting Breaker Volts AC (50/60 Hz) Volts DC
Class Type 240 480Y/277V 480 600Y/347V 600 250 500 600 (3P)
M MFAS 85 35 35 18 18 50 50 50
H HFAS 100 65 65 25 25 85 85 85
C CFAS 200 100 100 35 35 100 100 100

Trip Settings for 3VA52


TM210 - FTFM TM230 - FTAM
In (A) Ir (A) Ii (A) In (A) Ir (A) Ii (A)
100 100 1000 100 100 500 600 700 800 900 1000
110 110 1100 110 110 550 660 770 880 990 1100
125 125 1250 125 125 625 750 875 1000 1125 1125
150 150 1500 150 150 750 900 1050 1200 1350 1500
175 175 1750 175 175 875 1050 1225 1400 1575 1750
200 200 2000 200 200 3VA UL Molded
1000 1200 Case Circuit
1400 Breakers
1600 1800 2000
225 225 2250 225 225 Accessories
1125 and Spare
1350 Parts
1575 1800 2025 2250
250 250 2500 250 250 1250 1500 1750 2000 2250 2500
Internal accessories

Connectors for 75C Wire for 3VA52 Design

Minimum Maximum Part Number Internal accessories 3VA5


Type cable size cable size (kit of 3 lugs)
Optional equipment 250 A
Steel wrap around AWG 10 3/0 3VA9233-0JA11
(Cu cable only), 2(3)-pole & 3-pole
single cable lugs AWG 4 350 kcmil 3VA9233-0JA12
Aluminum body lug
(Cu/Al cable), AWG 6 350 kcmil 3VA9233-0JB12
single cable lugs 250 A

Aluminum body lug Slot No.: 24 23 22 21 11 12 13 14


(Cu/Al cable) with control AWG 6 350 kcmil 3VA9233-0JG12 Auxiliary switch Type
wire tap, single cable lugs
AUX_HQ x x x x x x x x
Aluminum body lug large
(Cu/Al cable) single cable AUX_HQ_el x x x x x x x x
AWG 2 350 kcmil 3VA9233-0JJ13 Auxiliary switch
lugs with 1 extended AUX_HP x x x x
terminal cover

7
x x
Aluminum body lug large LCS_HQ x
with control wire tap Leading

CIRCUIT BREAKERS
MOLDED CASE
(Cu/Al cable) single cable AWG 2 350 kcmil 3VA9233-0JC13 LCS_HQ_el x
changeover switch
lugs and 1 extended LCS_HP x
terminal cover Alarm switch Type
Aluminum body lug,
TAS_HQ x x x x
2 cables (Cu/Al cable)
AWG 4 300 kcmil 3VA9233-0JJ22 Trip alarm switch TAS_HQ_el x x x x
with control wire tap and
1 extended terminal cover TAS_HP x x
Distribution lug, 6 Cables Auxiliary release Type
(Cu/Al cable) with 1 AWG 14 AWG 2 3VA9233-0JF60
extended terminal cover STF x
Shunt trip flexible
Copper body lug
(Cu cable only) AWG 6 350 kcmil 3VA9233-0JD12
single cable lugs Shunt trip left STL x
Copper body lug with 4
control wire tap (Cu cable AWG 6 350 kcmil 3VA9233-0JK12 Undervoltage release UVR x
only) single cable lugs
Universal release UNI x
See page 7-73 for internal accessory Other
part numbers.
Cylinder lock (type Ronis) x
I201_19494

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-57


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA62 250A Electronic Trip Circuit Breakers Selection

Ordering Information
The catalog numbers listed below are for complete, non-interchangable
trip circuit breakers without lugs.
Order required lugs or connection technology separately for field installation.
All 3VA62 electronic trip circuit breakers are UL listed for reverse feed applications.
All 3VA62 electronic trip circuit breakers are available with 100% ratings.
For 100% rated electronic trip circuit breakers, change the 13th digit of the
catalog number to the number "2". (For example, a 35KA @480VAC, 100A,
3-pole, 100% rated 3VA62 would be catalog number 3VA6210-5HL31-2AA0)
Requires the use of rated lugs — see lug table below.
All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked
3VA62 250A 3-Pole “Naval”, and are suitable for use at 50C.

3VA62 250A Frame 3-Pole Electronic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class L-Interrupting Class E-Interrupting Class
(MFAE-Y) (HFAE-Y) (CFAE-Y) (LFAE-Y) (EFAE-Y)
Continuous
Ampere Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
ETU320 LI with dials
100 3VA6210-5HL31-0AA0 3VA6210-6HL31-0AA0 3VA6210-7HL31-0AA0 3VA6210-8HL31-0AA0 —
250 3VA6225-5HL31-0AA0 3VA6225-6HL31-0AA0 3VA6225-7HL31-0AA0 3VA6225-8HL31-0AA0 3VA6225-0HL31-0AA0
ETU330 LIG with dials
100 3VA6210-5HM31-0AA0 3VA6210-6HM31-0AA0 3VA6210-7HM31-0AA0 3VA6210-8HM31-0AA0 —
250 3VA6225-5HM31-0AA0 3VA6225-6HM31-0AA0 3VA6225-7HM31-0AA0 3VA6225-8HM31-0AA0 3VA6225-0HM31-0AA0
ETU350 LSI with dials
100 3VA6210-5HN31-0AA0 3VA6210-6HN31-0AA0 3VA6210-7HN31-0AA0 3VA6210-8HN31-0AA0 —
250 3VA6225-5HN31-0AA0 3VA6225-6HN31-0AA0 3VA6225-7HN31-0AA0 3VA6225-8HN31-0AA0 3VA6225-0HN31-0AA0
ETU550 LSI with LCD
100 3VA6210-5JP31-0AA0 3VA6210-6JP31-0AA0 3VA6210-7JP31-0AA0 3VA6210-8JP31-0AA0 —
250 3VA6225-5JP31-0AA0 3VA6225-6JP31-0AA0 3VA6225-7JP31-0AA0 3VA6225-8JP31-0AA0 —
ETU556 LSI(G Alarm) with LCD
100 3VA6210-5JT31-0AA0 3VA6210-6JT31-0AA0 3VA6210-7JT31-0AA0 3VA6210-8JT31-0AA0 —
7

250 3VA6225-5JT31-0AA0 3VA6225-6JT31-0AA0 3VA6225-7JT31-0AA0 3VA6225-8JT31-0AA0 —


ETU560 LSIG with LCD
MOLDED CASE
CIRCUIT BREAKERS

100 3VA6210-5JQ31-0AA0 3VA6210-6JQ31-0AA0 3VA6210-7JQ31-0AA0 3VA6210-8JQ31-0AA0 —


250 3VA6225-5JQ31-0AA0 3VA6225-6JQ31-0AA0 3VA6225-7JQ31-0AA0 3VA6225-8JQ31-0AA0 —
ETU820 LI with LCD and Metering
100 3VA6210-5KL31-0AA0 3VA6210-6KL31-0AA0 3VA6210-7KL31-0AA0 3VA6210-8KL31-0AA0 —
250 3VA6225-5KL31-0AA0 3VA6225-6KL31-0AA0 3VA6225-7KL31-0AA0 3VA6225-8KL31-0AA0 —
ETU830 LIG with LCD and Metering
100 3VA6210-5KM31-0AA0 3VA6210-6KM31-0AA0 3VA6210-7KM31-0AA0 3VA6210-8KM31-0AA0 —
250 3VA6225-5KM31-0AA0 3VA6225-6KM31-0AA0 3VA6225-7KM31-0AA0 3VA6225-8KM31-0AA0 —
ETU850 LSI with LCD and Metering
100 3VA6210-5KP31-0AA0 3VA6210-6KP31-0AA0 3VA6210-7KP31-0AA0 3VA6210-8KP31-0AA0 —
250 3VA6225-5KP31-0AA0 3VA6225-6KP31-0AA0 3VA6225-7KP31-0AA0 3VA6225-8KP31-0AA0 —
ETU856 LSI(G Alarm) with LCD and Metering
100 3VA6210-5KT31-0AA0 3VA6210-6KT31-0AA0 3VA6210-7KT31-0AA0 3VA6210-8KT31-0AA0 —
250 3VA6225-5KT31-0AA0 3VA6225-6KT31-0AA0 3VA6225-7KT31-0AA0 3VA6225-8KT31-0AA0 3VA6225-0KT31-0AA0
ETU860 LSIG with LCD and Metering
100 3VA6210-5KQ31-0AA0 3VA6210-6KQ31-0AA0 3VA6210-7KQ31-0AA0 3VA6210-8KQ31-0AA0 —
250 3VA6225-5KQ31-0AA0 3VA6225-6KQ31-0AA0 3VA6225-7KQ31-0AA0 3VA6225-8KQ31-0AA0 3VA6225-0KQ31-0AA0

7-58 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA62 250A Electronic Trip Circuit Breakers Selection

Ordering Information
The catalog numbers listed below are for complete, non-interchangable
trip circuit breakers without lugs.
Order required lugs or connection technology separately for field installation.
All 3VA62 electronict trip circuit breakers are UL listed for reverse feed applications.
All 3VA62 electronic trip circuit breakers are available with 100% ratings.
For 100% rated electronic trip circuit breakers, change the 13th digit of the
catalog number to the number "2". (For example, a 35KA @480VAC, 100A,
3-pole, 100% rated 3VA62 would be catalog number 3VA6210-5HL31-2AA0)
Requires the use of rated lugs — see lug table below.
All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked
3VA62 250A 4-Pole “Naval”, and are suitable for use at 50C.

3VA62 250A Frame 4-Pole Electronic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class L-Interrupting Class E-Interrupting Class
(MFAE-Y) (HFAE-Y) (CFAE-Y) (LFAE-Y) (EFAE-Y)
Continuous
Ampere Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
ETU320 LI with dials
100 3VA6210-5HL41-0AA0 3VA6210-6HL41-0AA0 3VA6210-7HL41-0AA0 3VA6210-8HL41-0AA0 —
250 3VA6225-5HL41-0AA0 3VA6225-6HL41-0AA0 3VA6225-7HL41-0AA0 3VA6225-8HL41-0AA0 3VA6225-0HL41-0AA0
ETU330 LIG with dials
100 3VA6210-5HM41-0AA0 3VA6210-6HM41-0AA0 3VA6210-7HM41-0AA0 3VA6210-8HM41-0AA0 —
250 3VA6225-5HM41-0AA0 3VA6225-6HM41-0AA0 3VA6225-7HM41-0AA0 3VA6225-8HM41-0AA0 3VA6225-0HM41-0AA0
ETU350 LSI with dials
100 3VA6210-5HN41-0AA0 3VA6210-6HN41-0AA0 3VA6210-7HN41-0AA0 3VA6210-8HN41-0AA0 —
250 3VA6225-5HN41-0AA0 3VA6225-6HN41-0AA0 3VA6225-7HN41-0AA0 3VA6225-8HN41-0AA0 3VA6225-0HN41-0AA0

ETU550 LSI with LCD


100 3VA6210-5JP41-0AA0 3VA6210-6JP41-0AA0 3VA6210-7JP41-0AA0 3VA6210-8JP41-0AA0 —
250 3VA6225-5JP41-0AA0 3VA6225-6JP41-0AA0 3VA6225-7JP41-0AA0 3VA6225-8JP41-0AA0 —
ETU556 LSI(G Alarm) with LCD
100 3VA6210-5JT41-0AA0 3VA6210-6JT41-0AA0 3VA6210-7JT41-0AA0 3VA6210-8JT41-0AA0 —

7
250 3VA6225-5JT41-0AA0 3VA6225-6JT41-0AA0 3VA6225-7JT41-0AA0 3VA6225-8JT41-0AA0 —
ETU560 LSIG with LCD

CIRCUIT BREAKERS
MOLDED CASE
100 3VA6210-5JQ41-0AA0 3VA6210-6JQ41-0AA0 3VA6210-7JQ41-0AA0 3VA6210-8JQ41-0AA0 —
250 3VA6225-5JQ41-0AA0 3VA6225-6JQ41-0AA0 3VA6225-7JQ41-0AA0 3VA6225-8JQ41-0AA0 —
ETU820 LI with LCD and Metering
100 3VA6210-5KL41-0AA0 3VA6210-6KL41-0AA0 3VA6210-7KL41-0AA0 3VA6210-8KL41-0AA0 —
250 3VA6225-5KL41-0AA0 3VA6225-6KL41-0AA0 3VA6225-7KL41-0AA0 3VA6225-8KL41-0AA0 —
ETU830 LIG with LCD and Metering
100 3VA6210-5KM41-0AA0 3VA6210-6KM41-0AA0 3VA6210-7KM41-0AA0 3VA6210-8KM41-0AA0 —
250 3VA6225-5KM41-0AA0 3VA6225-6KM41-0AA0 3VA6225-7KM41-0AA0 3VA6225-8KM41-0AA0 —
ETU850 LSI with LCD and Metering
100 3VA6210-5KP41-0AA0 3VA6210-6KP41-0AA0 3VA6210-7KP41-0AA0 3VA6210-8KP41-0AA0 —
250 3VA6225-5KP41-0AA0 3VA6225-6KP41-0AA0 3VA6225-7KP41-0AA0 3VA6225-8KP41-0AA0 —
ETU856 LSI(G Alarm) with LCD and Metering
100 3VA6210-5KT41-0AA0 3VA6210-6KT41-0AA0 3VA6210-7KT41-0AA0 3VA6210-8KT41-0AA0 —
250 3VA6225-5KT41-0AA0 3VA6225-6KT41-0AA0 3VA6225-7KT41-0AA0 3VA6225-8KT41-0AA0 3VA6225-0KT41-0AA0
ETU860 LSIG with LCD and Metering
100 3VA6210-5KQ41-0AA0 3VA6210-6KQ41-0AA0 3VA6210-7KQ41-0AA0 3VA6210-8KQ41-0AA0 —
250 3VA6225-5KQ41-0AA0 3VA6225-6KQ41-0AA0 3VA6225-7KQ41-0AA0 3VA6225-8KQ41-0AA0 3VA6225-0KQ41-0AA0

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-59


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA62 250A Electronic Trip Circuit Breakers Technical information

Connectors for 75C wire for 3VA62


Minimum Maximum Part Number Part Number
Type cable size cable size (kit of 3 lugs) (kit of 4 lugs)
Steel Wrap around (Cu cable only) AWG 10 3/0 3VA9143-0JA12 3VA9144-0JA12
single cable lugsa AWG 4 350 kcmil 3VA9243-0JA12 3VA9244-0JA12
Aluminum Body Lug (Cu/Al cable) AWG 14 1/0 3VA9143-0JB11 3VA9144-0JB11
single cable lugsa AWG 6 350 kcmil 3VA9243-0JB12 3VA9244-0JB12
Aluminum body lug with control wire tap AWG 14 1/0 3VA9143-0JG11 3VA9144-0JG11
(Cu/Al cable) single cable lugsa AWG 6 350 kcmil 3VA9243-0JG12 3VA9244-0JG12
Aluminum body lug large (Cu/Al cable)
AWG 2 350 kcmil 3VA9243-0JJ13 3VA9244-0JJ13
single cable lugs and 1 ext’d terminal covera
Aluminum body lug large with control wire tap
(Cu/Al cable) single cable lugs and AWG 2 350 kcmil 3VA9243-0JC13 3VA9244-0JC13
1 extended terminal covera
Aluminum body lug, 2 cables (Cu/Al cable)
AWG 4 300 kcmil 3VA9243-0JJ22 3VA9244-0JJ22
with 1 extended terminal covera
Aluminum body lug, 2 cables (Cu/Al cable) with
AWG 4 300 kcmil 3VA9243-0JC22 3VA9244-0JC22
control wire tap and 1 extended terminal covera
Distribution lug, 6 Cables (Cu/Al cable) with
AWG 14 AWG 2 3VA9243-0JF60 3VA9244-0JF60
1 extended terminal covera
Copper body lug (Cu cable only) AWG 14 1/0 3VA9143-0JD11a 3VA9144-0JD11a
single cable lugs AWG 6 350 kcmil 3VA9243-0JD12b 3VA9244-0JD12b
Copper body lug (Cu cable only) with control AWG 14 1/0 3VA9143-0JK11a 3VA9144-0JK11a
wire tap single cable lugs AWG 6 350 kcmil 3VA9243-0JK12b 3VA9244-0JK12b

Interrupting Ratings for 3VA62 Enclosures (3-pole only)


RMS Symmetrical Amperes (kA) Nema Type Catalog Number
Interrupting Breaker Volts AC (50/60 Hz) 1 surface 3VAE250N1S
Class Type 240 480Y/277V 480 600Y/347V 600 1 flush 3VAE250N1F
M MFAE-Y 100 35 35 18 — 3R 3VAE250N3R
H HFAE-Y 100 65 65 22 — 12 3VAE250N12
C CFAE-Y 200 100 100 35 — 4X (304) 3VAE250N4X
L LFAE-Y 200 150 150 50 — 4X (316) 3VAE250N4X316
Neutral N250X
200% Neutral N2250X
Dimensions Shipping Weight
7

Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg


3VA62 3 4.1 (105) 7.8 (198) 3.4 (86) 5.5 2.5
MOLDED CASE
CIRCUIT BREAKERS

3VA62 4 5.5 (140) 7.8 (198) 3.4 (86) 7.1 3.2

a Meets requirements for 100% rated breakers up to 100A.


b Meets requirements for 100% rated breakers up to 250A,
requires the use of 90 degree wire.

7-60 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 09/30/19

3VA Molded Case Circuit Breakers


3VA62 250A Electronic Trip Circuit Breakers Technical information

Trip Settings for 3VA62


ETU320-LI, ETU330-LIG, ETU350-LSI
Continuous LI, LIG, LSI
Amperage LI, LIG, LSI LSI LIG 4P only
Isd= xIr
In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I)a (Amp) (S) tsd (sec) (S) Ig (Amp) (G) IN=xIr (Amp)
100 40 - 100 0.5 - 17 150-1200 1.5 - 10 20 - 100 0.5 - 1 / OFF
0.08 - 0.4
250 100 - 250 0.5 - 13 375-2500 1.5 - 10 50 - 250 0.5 - 1 / OFF
a Ii for ETU350 is fixed at the maximum level shown in table.

ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG
Continuous LSI 3P with LI, LIG, LSI, LSIG,
Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) External CT LSI(G) 4P only
In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp)
100 40 - 100 0.5 - 25 150-1200 60 - 1000 20 - 100 20 - 160 / OFF 20 - 160 / OFF
0.05 - 0.5 0.05 - 0.8
250 100 - 250 0.5 - 13 375-2500 150 - 2500 50 - 250 50 - 400 / OFF 50 - 250 / OFF

For specific trip settings refer to the Electronic Trip Unit section3VA UL3VA
of the Molded Case
Systems Circuit Breakers
Manual,
which can be found in the document download center at https://www.siemens.com/download?BTLV_50412
Accessories and Spare Parts
Internal accessories
Internal accessories 3VA6 3VA6
Optional equipment 150/250 A 150/250 A
3-pole 4-pole

250 A 250 A

Slot No.: 24 23 22 21 11 12 13 14 34 33 32 31 24 23 22 21 11 12 13 14
Auxiliary switch Type
AUX_HQ x x x x x x x x x x x x x x x x x x x x
AUX_HQ_el x x x x x x x x x x x x x x x x x x x x
Auxiliary switch
AUX_HP x x x x x x x x x x
x x x x x
LCS_HQ x x
Leading changeover switch LCS_HQ_el x x
LCS_HP x x

7
Alarm switch Type
TAS_HQ x x x x x x x x

CIRCUIT BREAKERS
MOLDED CASE
Trip alarm switch TAS_HQ_el x x x x x x x x
TAS_HP x x x x
EAS_HQ x x
Electrical alarm switch
EAS_HQ_el x x
Auxiliary release Type

Shunt trip flexible STF x x x x

Shunt trip left STL x x


4
Undervoltage release UVR x x
Universal release UNI x x
ETU/communication Type
Communication module COM060
x x
Breaker data server
24 V module x x
Other
Cylinder lock (type Ronis) x x
I201_19495

See page 7-73 for internal accessory


part numbers.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-61


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA53 400A Thermal-magnetic Trip Circuit Breakers Selection

3VA53 400A, 2-Pole in 3-Pole Frame, Thermal-Magnetic Trip Unit


Cont. M-Interrupting Class H-Interrupting Class C-Interrupting Class
Ampere (MJAS) (HJAS) (CJAS)
Rating Catalog Number Catalog Number Catalog Number
TM230 FTAM
200 3VA5320-5EC61-0AA0 3VA5320-6EC61-0AA0 3VA5320-7EC61-0AA0
225 3VA5322-5EC61-0AA0 3VA5322-6EC61-0AA0 3VA5322-7EC61-0AA0
250 3VA5325-5EC61-0AA0 3VA5325-6EC61-0AA0 3VA5325-7EC61-0AA0
300 3VA5330-5EC61-0AA0 3VA5330-6EC61-0AA0 3VA5330-7EC61-0AA0
350 3VA5335-5EC61-0AA0 3VA5335-6EC61-0AA0 3VA5335-7EC61-0AA0
400 3VA5340-5EC61-0AA0 3VA5340-6EC61-0AA0 3VA5340-7EC61-0AA0

3VA53 400A Frame, 3-Pole Frame, Thermal-Magnetic Trip Unit


Cont. M-Interrupting Class H-Interrupting Class C-Interrupting Class
Ampere (MJAS) (HJAS) (CJAS)
Rating Catalog Number Catalog Number Catalog Number
TM230 FTAMa
200 3VA5320-5EC31-0AA0 3VA5320-6EC31-0AA0 3VA5320-7EC31-0AA0
225 3VA5322-5EC31-0AA0 3VA5322-6EC31-0AA0 3VA5322-7EC31-0AA0 3VA53 400A 3-Pole
250 3VA5325-5EC31-0AA0 3VA5325-6EC31-0AA0 3VA5325-7EC31-0AA0
300 3VA5330-5EC31-0AA0 3VA5330-6EC31-0AA0 3VA5330-7EC31-0AA0
350 3VA5335-5EC31-0AA0 3VA5335-6EC31-0AA0 3VA5335-7EC31-0AA0
Ordering Information
400 3VA5340-5EC31-0AA0 3VA5340-6EC31-0AA0 3VA5340-7EC31-0AA0
TM240 ATAM The catalog numbers listed here are
200 3VA5320-5EF31-0AA0 3VA5320-6EF31-0AA0 3VA5320-7EF31-0AA0 for complete, non-interchangable trip
225 3VA5322-5EF31-0AA0 3VA5322-6EF31-0AA0 3VA5322-7EF31-0AA0 circuit breakers without lugs.
250 3VA5325-5EF31-0AA0 3VA5325-6EF31-0AA0 3VA5325-7EF31-0AA0
Order required lugs or connection
300 3VA5330-5EF31-0AA0 3VA5330-6EF31-0AA0 3VA5330-7EF31-0AA0
technology separately for field
350 3VA5335-5EF31-0AA0 3VA5335-6EF31-0AA0 3VA5335-7EF31-0AA0
installation.
400 3VA5340-5EF31-0AA0 3VA5340-6EF31-0AA0 3VA5340-7EF31-0AA0
All 3VA53 thermal-magnetic trip
circuit breakers are UL listed for
reverse feed applications.
For NAVAL rated thermal-magnetic
7

trip circuit breakers, change the


13th digit of the catalog number
MOLDED CASE
CIRCUIT BREAKERS

to the number "1". (For example, a


35KA@480VAC, 400A, 3-pole, rated
3VA53 would be catalog number
3VA5340-5EC31-1AA0)

a Available with NAVAL/50C ratings.

7-62 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA53 400A Thermal-magnetic Trip Circuit Breakers Selection

3VA53 400A Frame, 4-Pole Frame, Thermal-Magnetic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class
Cont. (MJAS) (HJAS) (CJAS)
Ampere
Rating Catalog Number Catalog Number Catalog Number
TM230 FTAM Unprotected Neutral
200 3VA5320-5EC41-0AA0 3VA5320-6EC41-0AA0 3VA5320-7EC41-0AA0
225 3VA5322-5EC41-0AA0 3VA5322-6EC41-0AA0 3VA5322-7EC41-0AA0
250 3VA5325-5EC41-0AA0 3VA5325-6EC41-0AA0 3VA5325-7EC41-0AA0
300 3VA5330-5EC41-0AA0 3VA5330-6EC41-0AA0 3VA5330-7EC41-0AA0
350 3VA5335-5EC41-0AA0 3VA5335-6EC41-0AA0 3VA5335-7EC41-0AA0
400 3VA5340-5EC41-0AA0 3VA5340-6EC41-0AA0 3VA5340-7EC41-0AA0
TM240 ATAM Unprotected Neutral
200 3VA5320-5EF41-0AA0 3VA5320-6EF41-0AA0 3VA5320-7EF41-0AA0
225 3VA5322-5EF41-0AA0 3VA5322-6EF41-0AA0 3VA5322-7EF41-0AA0
250 3VA5325-5EF41-0AA0 3VA5325-6EF41-0AA0 3VA5325-7EF41-0AA0
300 3VA5330-5EF41-0AA0 3VA5330-6EF41-0AA0 3VA5330-7EF41-0AA0
350 3VA5335-5EF41-0AA0 3VA5335-6EF41-0AA0 3VA5335-7EF41-0AA0
400 3VA5340-5EF41-0AA0 3VA5340-6EF41-0AA0 3VA5340-7EF41-0AA0
TM230 FTAM 100% Neutral
3VA UL Molded Case Circuit Breakers
200 3VA5320-5GC41-0AA0 3VA5320-6GC41-0AA0 3VA5320-7GC41-0AA0 3VA53 400A 4-Pole
Accessories and Spare Parts
225 3VA5322-5GC41-0AA0 3VA5322-6GC41-0AA0 3VA5322-7GC41-0AA0
Internal accessories
250 3VA5325-5GC41-0AA0 3VA5325-6GC41-0AA0 3VA5325-7GC41-0AA0
Internal accessories 3VA5
300 3VA5330-5GC41-0AA0 3VA5330-6GC41-0AA0 3VA5330-7GC41-0AA0
Optional equipment 400/600 A
350 3VA5335-5GC41-0AA0 3VA5335-6GC41-0AA0 3VA5335-7GC41-0AA0 3 & 4-pole
400 3VA5340-5GC41-0AA0 3VA5340-6GC41-0AA0 3VA5340-7GC41-0AA0
TM240 ATAM 100% Neutral
200 3VA5320-5GF41-0AA0 3VA5320-6GF41-0AA0 3VA5320-7GF41-0AA0
600 A

Slot No.: 25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 2
225 3VA5322-5GF41-0AA0 3VA5322-6GF41-0AA0 3VA5322-7GF41-0AA0 Auxiliary switch Type
250 3VA5325-5GF41-0AA0 3VA5325-6GF41-0AA0 3VA5325-7GF41-0AA0 AUX_HQ x x x x x x x x x x x x x x x
300 3VA5330-5GF41-0AA0 3VA5330-6GF41-0AA0 3VA5330-7GF41-0AA0 Auxiliary switch
AUX_HQ_el x x x x x x x x x x x x x x x
AUX_HP x x x x x x
350 3VA5335-5GF41-0AA0 3VA5335-6GF41-0AA0 3VA5335-7GF41-0AA0 x x x x x x
400 3VA5340-5GF41-0AA0 3VA5340-6GF41-0AA0 3VA5340-7GF41-0AA0 LCS_HQ x
Leading
changeover LCS_HQ_el x
switch LCS_HP x
Alarm switch Type

7
Dimensions Shipping Weight Trip alarm switch
TAS_HQ
TAS_HQ_el
x
x
x
x
x
x
x
x
Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg TAS_HP x x

CIRCUIT BREAKERS
MOLDED CASE
Auxiliary release Type
3VA53 3 6.4 (162) 10.3 (262) 6.7 (170) 11.5 5.2
3VA53 4 8.2 (208) 10.3 (262) 6.7 (170) 15.0 6.8 Shunt trip flexible STF x x

Shunt trip left STL x

Undervoltage release UVR x


Interrupting Ratings for 3VA53 4 Universal release UNI x
Other
RMS Symmetrical Amperes (kA)
Cylinder lock (type Ronis) x
Volts AC (50/60 Hz) Volts DC
Interrupting Breaker 480Y/ 600Y/ 250 600 750 750 1000
Class Type 240 277V 480 347V 600 (2P) (3P) (3P) (4P) (4P)
M MJAS 85 35 35 18 18 50 50 10 50 10
H HJAS 100 65 65 25 25 85 85 10 85 10
C CJAS 200 100 100 35 35 100 100 10 100 10

4/6 Siemens · 04/2017

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-63


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA63 400A Electronic Trip Circuit Breakers Selection

Ordering Information
The catalog numbers listed below are for complete, non-interchangable
trip circuit breakers without lugs.
Order required lugs or connection technology separately for field installation.
All 3VA63 electronict trip circuit breakers are UL listed for reverse feed applications.
3VA63 electronic trip circuit breakers are available with 100% ratings (250A only).
For 100% rated electronic trip circuit breakers, change the 13th digit of the
catalog number to the number "2". (For example, a 35KA @480VAC, 250A,
3-pole, 100% rated 3VA63 would be catalog number 3VA6325-5HL31-2AA0)
Requires the use of rated lugs — see lug table below.
All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked
3VA63 400A 3-Pole “Naval”, and are suitable for use at 50C.

3VA63 400A Frame 3-Pole Electronic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class L-Interrupting Class E-Interrupting Class
(MJAE) (HJAE) (CJAE) (LJAE) (EJAE)
Continuous
Ampere Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
ETU320 LI with dials
250 3VA6325-5HL31-0AA0 3VA6325-6HL31-0AA0 3VA6325-7HL31-0AA0 3VA6325-8HL31-0AA0 3VA6325-0HL31-0AA0
400 3VA6340-5HL31-0AA0 3VA6340-6HL31-0AA0 3VA6340-7HL31-0AA0 3VA6340-8HL31-0AA0 3VA6340-0HL31-0AA0
ETU330 LIG with dials
250 3VA6325-5HM31-0AA0 3VA6325-6HM31-0AA0 3VA6325-7HM31-0AA0 3VA6325-8HM31-0AA0 3VA6325-0HM31-0AA0
400 3VA6340-5HM31-0AA0 3VA6340-6HM31-0AA0 3VA6340-7HM31-0AA0 3VA6340-8HM31-0AA0 3VA6340-0HM31-0AA0
ETU350 LSI with dials
250 3VA6325-5HN31-0AA0 3VA6325-6HN31-0AA0 3VA6325-7HN31-0AA0 3VA6325-8HN31-0AA0 3VA6325-0HN31-0AA0
400 3VA6340-5HN31-0AA0 3VA6340-6HN31-0AA0 3VA6340-7HN31-0AA0 3VA6340-8HN31-0AA0 3VA6340-0HN31-0AA0
ETU550 LSI with LCD
250 3VA6325-5JP31-0AA0 3VA6325-6JP31-0AA0 3VA6325-7JP31-0AA0 3VA6325-8JP31-0AA0 —
400 3VA6340-5JP31-0AA0 3VA6340-6JP31-0AA0 3VA6340-7JP31-0AA0 3VA6340-8JP31-0AA0 —
ETU556 LSI(G Alarm) with LCD
250 3VA6325-5JT31-0AA0 3VA6325-6JT31-0AA0 3VA6325-7JT31-0AA0 3VA6325-8JT31-0AA0 —
7

400 3VA6340-5JT31-0AA0 3VA6340-6JT31-0AA0 3VA6340-7JT31-0AA0 3VA6340-8JT31-0AA0 —


ETU560 LSIG with LCD
MOLDED CASE
CIRCUIT BREAKERS

250 3VA6325-5JQ31-0AA0 3VA6325-6JQ31-0AA0 3VA6325-7JQ31-0AA0 3VA6325-8JQ31-0AA0 —


400 3VA6340-5JQ31-0AA0 3VA6340-6JQ31-0AA0 3VA6340-7JQ31-0AA0 3VA6340-8JQ31-0AA0 —
ETU820 LI with LCD and Metering
250 3VA6325-5KL31-0AA0 3VA6325-6KL31-0AA0 3VA6325-7KL31-0AA0 3VA6325-8KL31-0AA0 —
400 3VA6340-5KL31-0AA0 3VA6340-6KL31-0AA0 3VA6340-7KL31-0AA0 3VA6340-8KL31-0AA0 —
ETU830 LIG with LCD and Metering
250 3VA6325-5KM31-0AA0 3VA6325-6KM31-0AA0 3VA6325-7KM31-0AA0 3VA6325-8KM31-0AA0 —
400 3VA6340-5KM31-0AA0 3VA6340-6KM31-0AA0 3VA6340-7KM31-0AA0 3VA6340-8KM31-0AA0 —
ETU850 LSI with LCD and Metering
250 3VA6325-5KP31-0AA0 3VA6325-6KP31-0AA0 3VA6325-7KP31-0AA0 3VA6325-8KP31-0AA0 —
400 3VA6340-5KP31-0AA0 3VA6340-6KP31-0AA0 3VA6340-7KP31-0AA0 3VA6340-8KP31-0AA0 —
ETU856 LSI(G Alarm) with LCD and Metering
250 3VA6325-5KT31-0AA0 3VA6325-6KT31-0AA0 3VA6325-7KT31-0AA0 3VA6325-8KT31-0AA0 3VA6325-0KT31-0AA0
400 3VA6340-5KT31-0AA0 3VA6340-6KT31-0AA0 3VA6340-7KT31-0AA0 3VA6340-8KT31-0AA0 3VA6340-0KT31-0AA0
ETU860 LSIG with LCD and Metering
250 3VA6325-5KQ31-0AA0 3VA6325-6KQ31-0AA0 3VA6325-7KQ31-0AA0 3VA6325-8KQ31-0AA0 3VA6325-0KQ31-0AA0
400 3VA6340-5KQ31-0AA0 3VA6340-6KQ31-0AA0 3VA6340-7KQ31-0AA0 3VA6340-8KQ31-0AA0 3VA6340-0KQ31-0AA0

7-64 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA63 400A Electronic Trip Circuit Breakers Selection

Interrupting Ratings for 3VA63


RMS Symmetrical Amperes (kA)
Interrupting Breaker Volts AC (50/60 Hz)
Class Type 240 480Y/277V 480 600Y/347V 600
M MJAE 100 35 35 18 18
H HJAE 100 65 65 22 22
C CJAE 200 100 100 35 35
L LJAE 200 150 150 50 50

Dimensions Shipping Weight


Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg
3VA63 3 6.4 (162) 10.3 (262) 6.7 (170) 11.0 5.2
3VA63 400A 4-Pole 3VA63 4 8.2 (208) 10.3 (262) 6.7 (170) 15.0 6.8

3VA63 400A Frame 4-Pole Electronic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class L-Interrupting Class E-Interrupting Class
(MJAE) (HJAE) (CJAE) (LJAE) (EJAE)
Continuous
Ampere Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
ETU320 LI with dials
250 3VA6325-5HL41-0AA0 3VA6325-6HL41-0AA0 3VA6325-7HL41-0AA0 3VA6325-8HL41-0AA0 3VA6325-0HL31-0AA0
400 3VA6340-5HL41-0AA0 3VA6340-6HL41-0AA0 3VA6340-7HL41-0AA0 3VA6340-8HL41-0AA0 3VA6340-0HL31-0AA0
ETU330 LIG with dials
250 3VA6325-5HM41-0AA0 3VA6325-6HM41-0AA0 3VA6325-7HM41-0AA0 3VA6325-8HM41-0AA0 3VA6325-0HM31-0AA0
400 3VA6340-5HM41-0AA0 3VA6340-6HM41-0AA0 3VA6340-7HM41-0AA0 3VA6340-8HM41-0AA0 3VA6340-0HM31-0AA0
ETU350 LSI with dials
250 3VA6325-5HN41-0AA0 3VA6325-6HN41-0AA0 3VA6325-7HN41-0AA0 3VA6325-8HN41-0AA0 3VA6325-0HN31-0AA0
400 3VA6340-5HN41-0AA0 3VA6340-6HN41-0AA0 3VA6340-7HN41-0AA0 3VA6340-8HN41-0AA0 3VA6340-0HN31-0AA0
ETU550 LSI with LCD
250 3VA6325-5JP41-0AA0 3VA6325-6JP41-0AA0 3VA6325-7JP41-0AA0 3VA6325-8JP41-0AA0 —
400 3VA6340-5JP41-0AA0 3VA6340-6JP41-0AA0 3VA6340-7JP41-0AA0 3VA6340-8JP41-0AA0 —
ETU556 LSI(G Alarm) with LCD
250 3VA6325-5JT41-0AA0 3VA6325-6JT41-0AA0 3VA6325-7JT41-0AA0 3VA6325-8JT41-0AA0 —

7
400 3VA6340-5JT41-0AA0 3VA6340-6JT41-0AA0 3VA6340-7JT41-0AA0 3VA6340-8JT41-0AA0 —
ETU560 LSIG with LCD

CIRCUIT BREAKERS
MOLDED CASE
250 3VA6325-5JQ41-0AA0 3VA6325-6JQ41-0AA0 3VA6325-7JQ41-0AA0 3VA6325-8JQ41-0AA0 —
400 3VA6340-5JQ41-0AA0 3VA6340-6JQ41-0AA0 3VA6340-7JQ41-0AA0 3VA6340-8JQ41-0AA0 —
ETU820 LI with LCD and Metering
250 3VA6325-5KL41-0AA0 3VA6325-6KL41-0AA0 3VA6325-7KL41-0AA0 3VA6325-8KL41-0AA0 —
400 3VA6340-5KL41-0AA0 3VA6340-6KL41-0AA0 3VA6340-7KL41-0AA0 3VA6340-8KL41-0AA0 —
ETU830 LIG with LCD and Metering
250 3VA6325-5KM41-0AA0 3VA6325-6KM41-0AA0 3VA6325-7KM41-0AA0 3VA6325-8KM41-0AA0 —
400 3VA6340-5KM41-0AA0 3VA6340-6KM41-0AA0 3VA6340-7KM41-0AA0 3VA6340-8KM41-0AA0 —
ETU850 LSI with LCD and Metering
250 3VA6325-5KP41-0AA0 3VA6325-6KP41-0AA0 3VA6325-7KP41-0AA0 3VA6325-8KP41-0AA0 —
400 3VA6340-5KP41-0AA0 3VA6340-6KP41-0AA0 3VA6340-7KP41-0AA0 3VA6340-8KP41-0AA0 —
ETU856 LSI(G Alarm) with LCD and Metering
250 3VA6325-5KT41-0AA0 3VA6325-6KT41-0AA0 3VA6325-7KT41-0AA0 3VA6325-8KT41-0AA0 3VA6325-0KT31-0AA0
400 3VA6340-5KT41-0AA0 3VA6340-6KT41-0AA0 3VA6340-7KT41-0AA0 3VA6340-8KT41-0AA0 3VA6340-0KT31-0AA0
ETU860 LSIG with LCD and Metering
250 3VA6325-5KQ41-0AA0 3VA6325-6KQ41-0AA0 3VA6325-7KQ41-0AA0 3VA6325-8KQ41-0AA0 3VA6325-0KQ31-0AA0
400 3VA6340-5KQ41-0AA0 3VA6340-6KQ41-0AA0 3VA6340-7KQ41-0AA0 3VA6340-8KQ41-0AA0 3VA6340-0KQ31-0AA0

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-65


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA63 400A Electronic Trip Circuit Breakers Technical information

Connections for 75C wire for 3VA53 and 3VA63


Minimum Maximum Part Number Part Number
Type cable size cable size (kit of 3 lugs) (kit of 4 lugs)
Steel wrap around (Cu cable only) single cable lugsa 1/0 500 kcmil 3VA9473-0JA13 3VA9474-0JA13
Aluminum body lug (Cu/Al cable) single cable lugsa AWG 1 600 kcmil 3VA9373-0JB13 3VA9374-0JB13
Aluminum body lug with control wire tap
AWG 1 600 kcmil 3VA9373-0JG13 3VA9374-0JG13
(Cu/Al cable) single cable lugsa
Aluminum body lug, 2 cables (Cu/Al cable) with
2/0 600 kcmil 3VA9473-0JJ23 3VA9474-0JJ23
1 extended terminal cover
Aluminum body lug, 2 cables (Cu/Al cable) with
2/0 600 kcmil 3VA9473-0JC23 3VA9474-0JC23
control wire tap and 1 extended terminal cover
Distribution lug, 6 Cables (Cu/Al cable) with
AWG 14 AWG 2 3VA9373-0JF60 3VA9374-0JF60
1 extended terminal covera
Copper body lug (Cu cable only) single cable lugsa AWG 1 600 kcmil 3VA9373-0JD13 3VA9374-0JD13
Copper body lug (Cu cable only) with
AWG 1 600 kcmil 3VA9373-0JK13 3VA9374-0JK13
control wire tap single cable lugsa
Copper body lug, 2 cables (Cu cable only) with
2/0 600 kcmil 3VA9473-0JE23 3VA9474-0JE23
1 extended terminal covera
Copper body lug, 2 cables (Cu cable only) with control 3VA UL Molded Case Circuit Breakers
2/0 600
Accessories and kcmil
Spare Parts 3VA9473-0JL23 3VA9474-0JL23
wire tap and 1 extended terminal covera
Internal accessories
a Meets requirements for 100% rated breakers up to 250A.
Internal accessories 3VA5 & 3VA6 3VA5 & 3VA6
Optional equipment 400/600 A 400/600 A
3-pole 4-pole

Enclosures for 3VA53 and


3VA63 (3-pole only) Slot No.:
600 A 600 A

25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 25 24 23 22 21 11 12 13 14 15
Auxiliary switch Type
NEMA Type Catalog Number
AUX_HQ x x x x x x x x x x x x x x x x x x x x x x x x x

1 Surface 3VAE6001S Auxiliary switch


AUX_HQ_el x x x x x x x x x x x x x x x x x x x x x x x x x
AUX_HP x x x x x x x x x x
1 Flush 3VAE6001F x x x x x x x x x x
LCS_HQ x x
3R 3VAE6003R Leading changeover switch LCS_HQ_el x x
LCS_HP x x
12 3VAE60012 Alarm switch Type
TAS_HQ x x x x x x x x
4X (304) 3VAE6004X Trip alarm switch TAS_HQ_el x x x x x x x x
TAS_HP x x x x
4X (316) 3VAE6004X316 EAS_HQ x x
Electrical alarm switch 
EAS_HQ_el x x
Neutral HN656ACB
7

Auxiliary release Type

200% Neutral HN678ACB Shunt trip flexible STF x x x x


MOLDED CASE
CIRCUIT BREAKERS

4 Shunt trip left STL x x

Undervoltage release UVR x x


Universal release UNI x x
ETU/communication  Type
Communication module COM060
x x
Breaker data server
24 V module x x

Trip Settings for 3VA63


Other
Cylinder lock (type Ronis) x x
I201_19495

ETU320-LI, ETU330-LIG, ETU350-LSI c These accessories are for


electronic trip breakers only.
Continuous LI, LIG, LSI
Amperage LI, LIG, LSI LSI LIG 4P only
Isd= xIr See page 7-73 for internal
In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I)d (Amp) (S) tsd (sec) (S) Ig (Amp) (G) IN=xIr (Amp) accessory part numbers.
250 100 - 250 0.5 - 17 375-3000 1.5 - 10 50 - 250 0.5 - 1 / OFF
0.08 - 0.4
400 150 - 400 0.5 - 17 600-4000 1.5 - 10 80 - 400 0.5 - 1 / OFF
d Ii for ETU350 is fixed at the maximum level shown in table.

ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG
Continuous LSI 3P with LI, LIG, LSI, LSIG,
Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) External CT LSI(G) 4P only
In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp)
250 100 - 250 0.5 - 25 375-3000 150 - 2500 50 - 250 50 - 400 / OFF 50 - 400 / OFF
4/6 0.05Siemens
- 0.5 · 04/2017 0.05 - 0.8
400 150 - 400 0.5 - 17 600-4000 240 - 4000 80 - 400 80 - 640 / OFF 80 - 400 / OFF
For specific trip settings refer to the Electronic Trip Unit section of the 3VA Systems Manual,
which can be found in the document download center at https://www.siemens.com/download?BTLV_50412

7-66 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA54 600A Thermal-magnetic Trip Circuit Breakers Selection

3VA54 600A, 2-Pole in 3-Pole Frame, Thermal-Magnetic Trip Unit


Cont. M-Interrupting Class H-Interrupting Class C-Interrupting Class
Ampere (MLAS) (HLAS) (CLAS)
Rating Catalog Number Catalog Number Catalog Number
TM230 FTAM
450 — 3VA5445-6EC61-0AA0 3VA5445-7EC61-0AA0
500 3VA5450-5EC61-0AA0 3VA5450-6EC61-0AA0 3VA5450-7EC61-0AA0
600 3VA5460-5EC61-0AA0 3VA5460-6EC61-0AA0 3VA5460-7EC61-0AA0

3VA54 600A Frame, 3-Pole Frame, Thermal-Magnetic Trip Unit


Cont. M-Interrupting Class H-Interrupting Class C-Interrupting Class
Ampere (MLAS) (HLAS) (CLAS)
Rating Catalog Number Catalog Number Catalog Number
TM230 FTAMa
450 3VA5445-5EC31-0AA0 3VA5445-6EC31-0AA0 3VA5445-7EC31-0AA0
500 3VA5450-5EC31-0AA0 3VA5450-6EC31-0AA0 3VA5450-7EC31-0AA0
600 3VA5460-5EC31-0AA0 3VA5460-6EC31-0AA0 3VA5460-7EC31-0AA0
TM240 ATAM
3VA54 600A 3-Pole
450 3VA5445-5EF31-0AA0 3VA5445-6EF31-0AA0 3VA5445-7EF31-0AA0
500 3VA5450-5EF31-0AA0 3VA5450-6EF31-0AA0 3VA5450-7EF31-0AA0
600 3VA5460-5EF31-0AA0 3VA5460-6EF31-0AA0 3VA5460-7EF31-0AA0

3VA54 600A Frame, 4-Pole Frame, Thermal-Magnetic Trip Unit


Cont. M-Interrupting Class H-Interrupting Class C-Interrupting Class
Ampere (MLAS) (HLAS) (CLAS)
Rating Catalog Number Catalog Number Catalog Number
TM230 FTAM Unprotected Neutral
450 3VA5445-5EC41-0AA0 3VA5445-6EC41-0AA0 3VA5445-7EC41-0AA0
500 3VA5450-5EC41-0AA0 3VA5450-6EC41-0AA0 3VA5450-7EC41-0AA0
600 3VA5460-5EC41-0AA0 3VA5460-6EC41-0AA0 3VA5460-7EC41-0AA0
TM240 ATAM Unprotected Neutral
450 3VA5445-5EF41-0AA0 3VA5445-6EF41-0AA0 3VA5445-7EF41-0AA0
500 3VA5450-5EF41-0AA0 3VA5450-6EF41-0AA0 3VA5450-7EF41-0AA0

7
600 3VA5460-5EF41-0AA0 3VA5460-6EF41-0AA0 3VA5460-7EF41-0AA0
TM230 FTFM 100% Neutral
450 3VA5445-5GC41-0AA0 3VA5445-6GC41-0AA0 3VA5445-7GC41-0AA0

CIRCUIT BREAKERS
MOLDED CASE
500 3VA5450-5GC41-0AA0 3VA5450-6GC41-0AA0 3VA5450-7GC41-0AA0
3VA54 600A 3-Pole
600 3VA5460-5GC41-0AA0 3VA5460-6GC41-0AA0 3VA5460-7GC41-0AA0
TM240 ATAM 100% Neutral
450 3VA5445-5GF41-0AA0 3VA5445-6GF41-0AA0 3VA5445-7GF41-0AA0
500 3VA5450-5GF41-0AA0 3VA5450-6GF41-0AA0 3VA5450-7GF41-0AA0
Ordering Information
600 3VA5460-5GF41-0AA0 3VA5460-6GF41-0AA0 3VA5460-7GF41-0AA0 The catalog numbers listed here are
for complete, non-interchangable trip
circuit breakers without lugs.
Dimensions Shipping Weight
Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg Order required lugs or connection
3VA54 3 6.4 (162) 10.3 (262) 6.7 (170) 11.5 5.2
technology separately for field
3VA54 4 8.2 (208) 10.3 (262) 6.7 (170) 15.0 6.8
installation.
All 3VA54 thermal-magnetic trip
circuit breakers are UL listed for
Interrupting Ratings for 3VA54 reverse feed applications.
RMS Symmetrical Amperes (kA)
Volts AC (50/60 Hz) Volts DC
For NAVAL rated thermal-magnetic
trip circuit breakers, change the
Interrupting Breaker 480Y/ 600Y/ 250 600 750 750 1000 13th digit of the catalog number
Class Type 240 277V 480 347V 600 (2P) (3P) (3P) (4P) (4P)
to the number "1". (For example,a
M MLAS 85 35 35 18 18 50 50 10 50 10
35KA@480VAC, 600A, 3-pole, rated
H HLAS 100 65 65 25 25 85 85 10 85 10
3VA54 would be catalog number
C CLAS 200 100 100 35 35 100 100 10 100 10
3VA5460-5EC31-1AA0)
a Available with NAVAL/50C ratings.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-67


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA64 600A Electronic Trip Circuit Breakers Selection

Ordering Information
The catalog numbers listed below are for complete, non-interchangable
trip circuit breakers without lugs.
Order required lugs or connection technology separately for field installation.
All 3VA64 electronict trip circuit breakers are UL listed for reverse feed applications.
3VA64 electronic trip circuit breakers are available with 100% ratings (400A only).
For 100% rated electronic trip circuit breakers, change the 13th digit of the
catalog number to the number "2". (For example, a 35KA @480VAC, 400A,
3-pole, 100% rated 3VA64 would be catalog number 3VA6440-5HL31-2AA0)
Requires the use of copper lugs — see lug table below.
All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked
3VA64 600A 3-Pole “Naval”, and are suitable for use at 50C.

3VA64 600A Frame 3-Pole Electronic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class L-Interrupting Class E-Interrupting Class
Continuous (MLAE) (HLAE) (CLAE) (LLAE) (ELAE)
Ampere Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
ETU320 LI with dials
400 3VA6440-5HL31-0AA0 3VA6440-6HL31-0AA0 3VA6440-7HL31-0AA0 3VA6440-8HL31-0AA0 —
600 3VA6460-5HL31-0AA0 3VA6460-6HL31-0AA0 3VA6460-7HL31-0AA0 3VA6460-8HL31-0AA0 3VA6460-0HL31-0AA0
ETU330 LIG with dials
400 3VA6440-5HM31-0AA0 3VA6440-6HM31-0AA0 3VA6440-7HM31-0AA0 3VA6440-8HM31-0AA0 —
600 3VA6460-5HM31-0AA0 3VA6460-6HM31-0AA0 3VA6460-7HM31-0AA0 3VA6460-8HM31-0AA0 3VA6460-0HM31-0AA0
ETU350 LSI with dials
400 3VA6440-5HN31-0AA0 3VA6440-6HN31-0AA0 3VA6440-7HN31-0AA0 3VA6440-8HN31-0AA0 —
600 3VA6460-5HN31-0AA0 3VA6460-6HN31-0AA0 3VA6460-7HN31-0AA0 3VA6460-8HN31-0AA0 3VA6460-0HN31-0AA0
ETU550 LSI with LCD
400 3VA6440-5JP31-0AA0 3VA6440-6JP31-0AA0 3VA6440-7JP31-0AA0 3VA6440-8JP31-0AA0 —
600 3VA6460-5JP31-0AA0 3VA6460-6JP31-0AA0 3VA6460-7JP31-0AA0 3VA6460-8JP31-0AA0 —
ETU556 LSI(G Alarm) with LCD
400 3VA6440-5JT31-0AA0 3VA6440-6JT31-0AA0 3VA6440-7JT31-0AA0 3VA6440-8JT31-0AA0 —
7

600 3VA6460-5JT31-0AA0 3VA6460-6JT31-0AA0 3VA6460-7JT31-0AA0 3VA6460-8JT31-0AA0 —


ETU560 LSIG with LCD
MOLDED CASE
CIRCUIT BREAKERS

400 3VA6440-5JQ31-0AA0 3VA6440-6JQ31-0AA0 3VA6440-7JQ31-0AA0 3VA6440-8JQ31-0AA0 —


600 3VA6460-5JQ31-0AA0 3VA6460-6JQ31-0AA0 3VA6460-7JQ31-0AA0 3VA6460-8JQ31-0AA0 —
ETU820 LI with LCD and Metering
400 3VA6440-5KL31-0AA0 3VA6440-6KL31-0AA0 3VA6440-7KL31-0AA0 3VA6440-8KL31-0AA0 —
600 3VA6460-5KL31-0AA0 3VA6460-6KL31-0AA0 3VA6460-7KL31-0AA0 3VA6460-8KL31-0AA0 —
ETU830 LIG with LCD and Metering
400 3VA6440-5KM31-0AA0 3VA6440-6KM31-0AA0 3VA6440-7KM31-0AA0 3VA6440-8KM31-0AA0 —
600 3VA6460-5KM31-0AA0 3VA6460-6KM31-0AA0 3VA6460-7KM31-0AA0 3VA6460-8KM31-0AA0 —
ETU850 LSI with LCD and Metering
400 3VA6440-5KP31-0AA0 3VA6440-6KP31-0AA0 3VA6440-7KP31-0AA0 3VA6440-8KP31-0AA0 —
600 3VA6460-5KP31-0AA0 3VA6460-6KP31-0AA0 3VA6460-7KP31-0AA0 3VA6460-8KP31-0AA0 —
ETU856 LSI(G Alarm) with LCD and Metering
400 3VA6440-5KT31-0AA0 3VA6440-6KT31-0AA0 3VA6440-7KT31-0AA0 3VA6440-8KT31-0AA0 —
600 3VA6460-5KT31-0AA0 3VA6460-6KT31-0AA0 3VA6460-7KT31-0AA0 3VA6460-8KT31-0AA0 3VA6460-0KT31-0AA0
ETU860 LSIG with LCD and Metering
400 3VA6440-5KQ31-0AA0 3VA6440-6KQ31-0AA0 3VA6440-7KQ31-0AA0 3VA6440-8KQ31-0AA0 —
600 3VA6460-5KQ31-0AA0 3VA6460-6KQ31-0AA0 3VA6460-7KQ31-0AA0 3VA6460-8KQ31-0AA0 3VA6460-0KQ31-0AA0

7-68 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA64 600A Electronic Trip Circuit Breakers Selection

Interrupting Ratings for 3VA64


RMS Symmetrical Amperes (kA)
Interrupting Breaker Volts AC (50/60 Hz)
Class Type 240 480Y/277V 480 600Y/347V 600
M MLAE 100 35 35 18 18
H HLAE 100 65 65 22 22
C CLAE 200 100 100 35 35
L LLAE 200 150 150 50 50

Dimensions Shipping Weight


Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg
3VA64 3 6.4 (162) 10.3 (262) 6.7 (170) 11.0 5.2
3VA64 600A 4-Pole 3VA64 4 8.2 (208) 10.3 (262) 6.7 (170) 15.0 6.8

3VA64 600A Frame 4-Pole Electronic Trip Unit


M-Interrupting Class H-Interrupting Class C-Interrupting Class L-Interrupting Class E-Interrupting Class
(MLAE) (HLAE) (CLAE) (LLAE) (ELAE)
Continuous
Ampere Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
ETU320 LI with dials
400 3VA6440-5HL41-0AA0 3VA6440-6HL41-0AA0 3VA6440-7HL41-0AA0 3VA6440-8HL41-0AA0 —
600 3VA6460-5HL41-0AA0 3VA6460-6HL41-0AA0 3VA6460-7HL41-0AA0 3VA6460-8HL41-0AA0 3VA6460-0HL41-0AA0
ETU330 LIG with dials
400 3VA6440-5HM41-0AA0 3VA6440-6HM41-0AA0 3VA6440-7HM41-0AA0 3VA6440-8HM41-0AA0 —
600 3VA6460-5HM41-0AA0 3VA6460-6HM41-0AA0 3VA6460-7HM41-0AA0 3VA6460-8HM41-0AA0 3VA6460-0HM41-0AA0
ETU350 LSI with dials
400 3VA6440-5HN41-0AA0 3VA6440-6HN41-0AA0 3VA6440-7HN41-0AA0 3VA6440-8HN41-0AA0 —
600 3VA6460-5HN41-0AA0 3VA6460-6HN41-0AA0 3VA6460-7HN41-0AA0 3VA6460-8HN41-0AA0 3VA6460-0HN41-0AA0
ETU550 LSI with LCD
400 3VA6440-5JP41-0AA0 3VA6440-6JP41-0AA0 3VA6440-7JP41-0AA0 3VA6440-8JP41-0AA0 —
600 3VA6460-5JP41-0AA0 3VA6460-6JP41-0AA0 3VA6460-7JP41-0AA0 3VA6460-8JP41-0AA0 —
ETU556 LSI(G Alarm) with LCD
400 3VA6440-5JT41-0AA0 3VA6440-6JT41-0AA0 3VA6440-7JT41-0AA0 3VA6440-8JT41-0AA0 —

7
600 3VA6460-5JT41-0AA0 3VA6460-6JT41-0AA0 3VA6460-7JT41-0AA0 3VA6460-8JT41-0AA0 —
ETU560 LSIG with LCD

CIRCUIT BREAKERS
MOLDED CASE
400 3VA6440-5JQ41-0AA0 3VA6440-6JQ41-0AA0 3VA6440-7JQ41-0AA0 3VA6440-8JQ41-0AA0 —
600 3VA6460-5JQ41-0AA0 3VA6460-6JQ41-0AA0 3VA6460-7JQ41-0AA0 3VA6460-8JQ41-0AA0 —
ETU820 LI with LCD and Metering
400 3VA6440-5KL41-0AA0 3VA6440-6KL41-0AA0 3VA6440-7KL41-0AA0 3VA6440-8KL41-0AA0 —
600 3VA6460-5KL41-0AA0 3VA6460-6KL41-0AA0 3VA6460-7KL41-0AA0 3VA6460-8KL41-0AA0 —
ETU830 LIG with LCD and Metering
400 3VA6440-5KM41-0AA0 3VA6440-6KM41-0AA0 3VA6440-7KM41-0AA0 3VA6440-8KM41-0AA0 —
600 3VA6460-5KM41-0AA0 3VA6460-6KM41-0AA0 3VA6460-7KM41-0AA0 3VA6460-8KM41-0AA0 —
ETU850 LSI with LCD and Metering
400 3VA6440-5KP41-0AA0 3VA6440-6KP41-0AA0 3VA6440-7KP41-0AA0 3VA6440-8KP41-0AA0 —
600 3VA6460-5KP41-0AA0 3VA6460-6KP41-0AA0 3VA6460-7KP41-0AA0 3VA6460-8KP41-0AA0 —
ETU856 LSI(G Alarm) with LCD and Metering
400 3VA6440-5KT41-0AA0 3VA6440-6KT41-0AA0 3VA6440-7KT41-0AA0 3VA6440-8KT41-0AA0 —
600 3VA6460-5KT41-0AA0 3VA6460-6KT41-0AA0 3VA6460-7KT41-0AA0 3VA6460-8KT41-0AA0 3VA6460-0KT41-0AA0
ETU860 LSIG with LCD and Metering
400 3VA6440-5KQ41-0AA0 3VA6440-6KQ41-0AA0 3VA6440-7KQ41-0AA0 3VA6440-8KQ41-0AA0 —
600 3VA6460-5KQ41-0AA0 3VA6460-6KQ41-0AA0 3VA6460-7KQ41-0AA0 3VA6460-8KQ41-0AA0 3VA6460-0KQ41-0AA0

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-69


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA64 600A Electronic Trip Circuit Breakers Technical information

Connections for 75C wire for 3VA54 and 3VA64


Minimum Maximum Part Number Part Number
Type cable size cable size (kit of 3 lugs) (kit of 4 lugs)
Steel Wrap around (Cu cable only) single cable lugs 1/0 500 kcmil 3VA9473-0JA13 3VA9474-0JA13
Aluminum Body Lug (Cu/Al cable) single cable lugs AWG 1 600 kcmil 3VA9373-0JB13 3VA9374-0JB13
Aluminum body lug with control wire tap
AWG 1 600 kcmil 3VA9373-0JG13 3VA9374-0JG13
(Cu/Al cable) single cable lugs
Aluminum body lug, 2 cables (Cu/Al cable) with
2/0 600 kcmil 3VA9473-0JJ23 3VA9474-0JJ23
1 extended terminal cover
Aluminum body lug, 2 cables (Cu/Al cable) with
2/0 600 kcmil 3VA9473-0JC23 3VA9474-0JC23
control wire tap and 1 extended terminal cover
Distribution lug, 6 Cables (Cu/Al cable) with
AWG 14 AWG 2 3VA9373-0JF60 3VA9374-0JF60
1 extended terminal cover
Copper body lug (Cu cable only) single cable lugsa AWG 1 600 kcmil 3VA9373-0JD13 3VA9374-0JD13
Copper body lug (Cu cable only) with
AWG 1 600 kcmil 3VA9373-0JK13 3VA9374-0JK13
control wire tap single cable lugsa
Copper body lug, 2 cables (Cu cable only) with
2/0 600 kcmil 3VA9473-0JE23 3VA9474-0JE23
1 extended terminal coverb
Copper body lug, 2 cables (Cu cable only) 3VA UL Molded600
Case Circuit Breakers
2/0 kcmil 3VA9473-0JL23 3VA9474-0JL23
with control wire tap and 1 extended terminal coverb Accessories and Spare Parts
a Meets the requirement for 100% rated breakers up to 400A. Internal accessories
b Meets requirement for 100% rated breakers up to 400A, Internal accessories 3VA5 & 3VA6 3VA5 & 3VA6
requires the use of 90 degree wire.
Optional equipment 400/600 A 400/600 A
3-pole 4-pole
Enclosures for 3VA54 and
3VA64 (3-pole only) 600 A 600 A

Slot No.: 25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 25 24 23 22 21 11 12 13 14 15
NEMA Type Catalog Number Auxiliary switch Type
AUX_HQ x x x x x x x x x x x x x x x x x x x x x x x x x
1 Surface 3VAE6001S AUX_HQ_el x x x x x x x x x x x x x x x x x x x x x x x x x
Auxiliary switch
AUX_HP x x x x x x x x x x
1 Flush 3VAE6001F x x x x x x x x x x
LCS_HQ x x
3R 3VAE6003R Leading changeover switch LCS_HQ_el x x
LCS_HP x x
12 3VAE60012
Alarm switch Type

4X (304) 3VAE6004X TAS_HQ x x x x x x x x


Trip alarm switch TAS_HQ_el x x x x x x x x
4X (316) 3VAE6004X316 TAS_HP x x x x
EAS_HQ x x
Electrical alarm switch 
Neutral HN656ACB
7

EAS_HQ_el x x
Auxiliary release Type
200% Neutral HN678ACB
MOLDED CASE
CIRCUIT BREAKERS

Shunt trip flexible STF x x x x

4 Shunt trip left STL x x

Undervoltage release UVR x x


Universal release UNI x x

ETU/communication Type
Communication module COM060
x x
Breaker data server
24 V module x x
Other

Trip Settings for 3VA64 Cylinder lock (type Ronis) x x


I201_19495

ETU320-LI, ETU330-LIG, ETU350-LSI b These accessories are for


electronic trip breakers only.
Continuous LI, LIG, LSI
Amperage LI, LIG, LSI LSI LIG 4P only
Isd= xIr See page 7-73 for internal
In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I)c (Amp) (S) tsd (sec) (S) Ig (Amp) (G) IN=xIr (Amp) accessory part numbers.
400 150 - 400 0.5 - 17 600-4800 1.5 - 10 80 - 400 0.5 - 1 / OFF
0.08 - 0.4
600 250 - 600 0.5 - 15 900-5400 1.5 - 9 120 - 600 0.5 - 1 / OFF
c Ii for ETU350 is fixed at the maximum level shown in table.
ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG
Continuous LSI 3P with LI, LIG, LSI, LSIG,
Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) External CT LSI(G) 4P only
In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp)
400 150 - 400 0.5 - 25 600-4800 240 - 4000 80 - 400 80 - 640 / OFF 80 - 600 / OFF
4/6 0.05Siemens
- 0.5 · 04/2017 0.05 - 0.8
600 250 - 600 0.5 - 15 900-5400 360 - 5400 120 - 600 120 - 960 / OFF 120 - 600 / OFF
For specific trip settings refer to the Electronic Trip Unit section of the 3VA Systems Manual,
which can be found in the document download center at https://www.siemens.com/download?BTLV_50412

7-70 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 09/30/19

3VA Molded Case Circuit Breakers


3VA Molded Case Switch and Motor Circuit Protector Selection

Breaking capacity (the SCCR rating) is the maximum permissible


short circuit current at the installation location of the MCS in
combination with an appropriate overload protective device.

Molded Case Switch Magnetic


Short-Circuit Current
Frame Max. 2-Pole 3-Pole Rating Instantaneous
(Breaker Ampere short circuit
Type) Rating Catalog Number Catalog Number 240V 480V 600V protection
3VA51
100 3VA5110-1BB21-0AA0 3VA5110-1BB31-0AA0 100k 65k 14ka 1600 A
(HEAS)
3VA52 150 3VA5215-0BB61-0AA0 3VA5215-0BB31-0AA0 100k 65k 25k 2400 A
(HFAS) 250 3VA5225-0BB61-0AA0 3VA5225-0BB31-0AA0 100k 65k 25k 2500 A
3VA53
400 3VA5340-0BB61-0AA0 3VA5340-0BB31-0AA0 100k 65k 25k 6000 A
(HJAS)
3VA54
600 3VA5460-0BB61-0AA0 3VA5460-0BB31-0AA0 100k 65k 25k 6000 A Magnetic switch
(HLAS)

100 3VA5210-1BB61-0AA0 3VA5210-1BB31-0AA0 200k 100k 35k 2500 A


3VA52
150 3VA5215-1BB61-0AA0 3VA5215-1BB31-0AA0 200k 100k 35k 2400 A
(CFAS)
250 3VA5225-1BB61-0AA0 3VA5225-1BB31-0AA0 200k 100k 35k 2500 A
3VA53
400 3VA5340-1BB61-0AA0 3VA5340-1BB31-0AA0 200k 100k 35k 6000 A
(CJAS)
3VA54
600 3VA5460-1BB61-0AA0 3VA5460-1BB31-0AA0 200k 100k 35k 6000 A
(CLAS)

Molded Case Switch Electronic


Frame Max. Short-Circuit Current Instantaneous
(Breaker Ampere 2-Pole 3-Pole Rating short circuit
Type) Rating Catalog Number Catalog Number 240V 480V 600V protection
3VA63
400 — 3VA6340-1BB31-0AA0 200k 100k 35k 5600 A
(CJAE)
3VA64 Electronic Trip Unit switch
600 — 3VA6460-1BB31-0AA0 200k 100k 35k 5400 A
(CLAE)

7
CIRCUIT BREAKERS
MOLDED CASE

a Rated at 600 Y/347 V AC.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-71


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA Molded Case Switch and Motor Circuit Protector Selection

Motor circuit protector TM120M AMc


Frame Maximum Instantaneous
(Breaker Ampere 3-Pole short circuit
Type) Rating Catalog Number protection
3VA51 1 3VA5181-1MU31-0AA0 3 ... 7
(HEAP) 3VA5181-1MH31-0AA0 5 ... 12 Motor
2 3VA5102-1MU31-0AA0 6 ... 14 Circuit
3VA5102-1MH31-0AA0 10 ... 24 Protector
3 3VA5103-1MU31-0AA0 9 ... 21
3VA5103-1MH31-0AA0 15 ... 36
5 3VA5105-1MU31-0AA0 15 ... 35
3VA5105-1MH31-0AA0 25 ... 60
7 3VA5107-1MU31-0AA0 21 ... 49
3VA5107-1MH31-0AA0 35 ... 84
10 3VA5191-1MU31-0AA0 30 ... 70
3VA5191-1MH31-0AA0 50 ... 120
15 3VA5195-1MU31-0AA0 45 ... 105
Motor circuit protector TM120M AMb
3VA52 150 3VA5215-1MU31-0AA0 450 ... 900
3VA5195-1MH31-0AA0 75 ... 180
(CFAP) 3VA5215-1MH31-0AA0 900 ... 1800
25 3VA5125-1MU31-0AA0 75 ... 175
200 3VA5220-1MU31-0AA0 600 ... 1200
3VA5125-1MH31-0AA0 125 ... 300
3VA5220-1MH31-0AA0 1200 ... 2400
30 3VA5130-1MU31-0AA0 90 ... 210
250 3VA5225-1MH31-0AA0 750 ... 900
3VA5130-1MH31-0AA0 150 ... 360
3VA5225-1MU31-0AA0 1250 ... 2500
40 3VA5140-1MU31-0AA0 120 ... 280
3VA53 250 3VA5325-1MU31-0AA0 750 ... 1500
3VA5140-1MH31-0AA0 200 ... 480
(CJAP) 3VA5325-1MH31-0AA0 1500 ... 3000
50 3VA5150-1MU31-0AA0 150 ... 350
3VA5150-1MH31-0AA0 250 ... 600 3VA54 400 3VA5440-1MU31-0AA0 750 ... 1500
70 3VA5170-1MU31-0AA0 210 ... 490 (CLAP) 3VA5440-1MH31-0AA0 2400 ... 4800
3VA5170-1MH31-0AA0 350 ... 840 500 3VA5450-1MU31-0AA0 1500 ... 3000
80 3VA5180-1MU31-0AA0 240 ... 560 3VA5450-1MH31-0AA0 3000 ... 6000
3VA5180-1MH31-0AA0 400 ... 960 600 3VA5460-1MU31-0AA0 1500 ... 3000
90 3VA5190-1MU31-0AA0 270 ... 630 3VA5460-1MH31-0AA0 3000 ... 6000
3VA5190-1MH31-0AA0 450 ... 1080
100 3VA5110-1MU31-0AA0 300 ... 700 Motor circuit protector ETU310Mb
3VA5110-1MH31-0AA0 500 ... 1200
Frame Maximum Instantaneous
110 3VA5111-1MU31-0AA0 330 ... 770
(Breaker Ampere 3-Pole short circuit
3VA5111-1MH31-0AA0 550 ... 1320 Type) Rating Catalog Number protection
125 3VA5112-1MU31-0AA0 375 ... 875
3VA61 25 3VA6125-1MS31-0AA0 75 ... 375
3VA5112-1MH31-0AA0 625 ... 1500 (CDAR) 30 3VA6130-1MS31-0AA0 90 ... 450
3VA52 150 3VA5215-0MU31-0AA0 450 ... 900 40 3VA6140-1MS31-0AA0 120 ... 600
(HFAP) 3VA5215-0MH31-0AA0 900 ... 1800
7

50 3VA6150-1MS31-0AA0 150 ... 750


200 3VA5220-0MU31-0AA0 600 ... 1200 70 3VA6170-1MS31-0AA0 210 ... 1050
3VA5220-0MH31-0AA0 1200 ... 2400 80 3VA6180-1MS31-0AA0 240 ... 1200
MOLDED CASE
CIRCUIT BREAKERS

250 3VA5225-0MU31-0AA0 750 ... 900 90 3VA6190-1MS31-0AA0 270 ... 1350


3VA5225-0MH31-0AA0 1250 ... 2500 100 3VA6110-1MS31-0AA0 300 ... 1500
3VA53 250 3VA5325-0MU31-0AA0 750 ... 1500 3VA62 110 3VA6211-1MS31-0AA0 330 ... 1650
(HJAP) 3VA5325-0MH31-0AA0 1500 ... 3000 (CFAR-Y) 125 3VA6212-1MS31-0AA0 375 ... 1875
3VA54 400 3VA5440-0MU31-0AA0 750 ... 1500 150 3VA6215-1MS31-0AA0 450 ... 2250
(HLAP 3VA5440-0MH31-0AA0 1200 ... 2400 200 3VA6220-1MS31-0AA0 600 ... 2400
500 3VA5450-0MU31-0AA0 1500 ... 3000 3VA63 200 3VA6320-1MS31-0AA0 600 ... 3000
3VA5450-0MH31-0AA0 3000 ... 6000 (CJAR) 250 3VA6325-1MS31-0AA0 750 ... 3750
600 3VA5460-0MU31-0AA0 1800 ... 3600 3VA64 400 3VA6440-1MS31-0AA0 1200 ... 5200
3VA5460-0MH31-0AA0 3000 ... 6000 (CLAR) 500 3VA6450-1MS31-0AA0 1500 ... 6000

Interrupting Ratings
RMS Symmetrical Amperes (kA)
Volts AC (50/60 Hz) Volts DC
Breaker 600Y/
Frame Type 240 480 347V 600 125 (1P) 250 (2P) 500d (3P) 600 (3P)
3VA51 HEAP 150 65 25 — 30 100 100 —
HFAP 100 65 25 25 85 85
3VA52
CFAP 200 100 35 35 100 100
HJAP 100 65 25 25 — — — —
3VA53
CHAP 200 100 35 35 — — — — a Rated at 600 Y/347 V AC.
HLAP 100 65 25 25 — — — —
b SCCR is 100kA at 480 V. SCCR rating is the maximum
3VA54 permissible short circuit current of the MCP in combina-
CLAP 200 100 35 35 — — — — tion with an appropriate overload protection device.
3VA61 CDAR 200 100 35 35 — — — — c SCCR is 65kA at 480 V. SCCR rating is the maximum
3VA62 CFAR 200 100 35 — — — — — permissible short circuit current of the MCP in combination
with an appropriate overload protection device.
3VA63 CJAR 200 100 35 35 — — — — d 2 poles required for 500VDC for breaker types HFAP
3VA64 CLAR 200 100 35 35 — — — — and CFAP.

7-72 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/28/19

3VA Molded Case Circuit Breakers


3VA Internal Accessories Selection

Internal Accessories­ Auxiliary switches and


alarm switches HQ

Auxiliary and Alarm Switches


Catalog Number
Switch HP High Power HQ Compact HQ Electronica
Type (2 slots) (1 slot) (1 slot)
Auxiliary Switch
3VA9978-0AA11 3VA9978-0AA12 3VA9978-0AA13
(AUX)
Leading Changeover
3VA9978-0AA21 3VA9978-0AA22 3VA9978-0AA23
Switch (LCS)
Trip Alarm Switch
3VA9978-0AB11 3VA9978-0AB12 3VA9978-0AB13
(TAS)
Electronic Alarm
— 3VA9978-0AB22 3VA9978-0AB23
(EAS)
AUX LCS TAS EAS

Shunt Trips
Catalog Number Auxiliary switches and
Type VAC 50/60 Hz VDC (3 slots) alarm switches HP
380 ... 600 — 3VA9978-0BL20
— 12 3VA9978-0BL10
Shunt Trip Left 24 24 ... 30 3VA9978-0BL30
(STL) 48 ... 60 — 3VA9978-0BL31
110 ... 127 110 ... 127 3VA9978-0BL32
208 ... 277 220 ... 250 3VA9978-0BL33
24 — 3VA9978-0BA20
48 ... 60 — 3VA9978-0BA21
Shunt Trip Flexible 110 ... 127 — 3VA9978-0BA22
(STF)b 208 ... 277 — 3VA9978-0BA23
380 ... 500 — 3VA9978-0BA24
600 — 3VA9978-0BA25
AUX LCS TAS
Undervoltage Release
— 12 3VA9978-0BB10
— 24 3VA9978-0BB11 Shunt trip left Undervoltage
— 48 3VA9978-0BB12 STL releases UVR

7
— 125 ... 127 3VA9978-0BB14
Undervoltage Release
— 250 3VA9978-0BB16
(UVR)
24 — 3VA9978-0BB20

CIRCUIT BREAKERS
MOLDED CASE
120 ... 127 — 3VA9978-0BB24
208 ... 230 — 3VA9978-0BB25
440 ... 480 — 3VA9978-0BB27

Universal Release (Undervoltage and Shunt trip)


— 12 3VA9978-0BD11
Universal Release
— 24 3VA9978-0BD12
(UNI)
— 48 3VA9978-0BD13

Time-delay Device for Undervoltage Release Universal


release UNI
Time-delay device
for undervoltage
Type VAC 50/60 Hz VDC Delay Time Catalog Number releases
230 230 Fixed – 100ms minimum 3VA9978-0BF22
Time-delay Device
— 24 Fixed – 100ms minimum 3VA9978-0BF23

a Use only with 3VA6. b Shunt trip flexible can be used in the left pocket of the
3VA5 breakers. They can be used in the left or right
pocket of the 3VA6 breakers.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-73


Revised on 10/31/18

3VA Molded Case Circuit Breakers


3VA Manual Operators Selection

Front Mounted Rotary Operator


3VA6 3VA6
3VA5 3VA5 150A 400A
Type Color 125A 250A 250A 600A Catalog Number
Standard without illumination kit Gray u — — — 3VA9137-0EK11
— u u — 3VA9277-0EK11
— — — u 3VA9447-0EK11
Standard with illumination kit Gray u — — — 3VA9137-0EK13
— u u — 3VA9277-0EK13
— — — u 3VA9447-0EK13
EMERGENCY-OFF Yellow-Red u — — — 3VA9137-0EK15
without illumination kit
— u u — 3VA9277-0EK15
— — — u 3VA9447-0EK15
Degree of protection NEMA 1
EMERGENCY-OFF Yellow-Red u — — — 3VA9137-0EK17
with illumination kit
— u u — 3VA9277-0EK17
— — — u 3VA9447-0EK17
Standard with door interlock Gray u — — — 3VA9137-0EK21
— u u — 3VA9277-0EK21
— — — u 3VA9447-0EK21
Standard with door interlock, Gray u — — — 3VA9137-0EK23
with illumination kit
— u u — 3VA9277-0EK23
— — — u 3VA9447-0EK23
EMERGENCY-OFF Yellow-Red u — — — 3VA9137-0EK25
with door interlock
— u u — 3VA9277-0EK25
— — — u 3VA9447-0EK25
EMERGENCY-OFF with door interlock, Yellow-Red u — — — 3VA9137-0EK27
with illumination kit
— u u — 3VA9277-0EK27
— — — u 3VA9447-0EK27
Standard with door interlock, Gray u — — — 3VA9137-0EK31
with door open function
— u u — 3VA9277-0EK31
7

— — — u 3VA9447-0EK31
Standard with door interlock, Gray u — — — 3VA9137-0EK33
MOLDED CASE
CIRCUIT BREAKERS

with door open function,


— u u — 3VA9277-0EK33
with illumination kit
— — — u 3VA9447-0EK33
EMERGENCY-OFF with door interlock, Yellow-Red u — — — 3VA9137-0EK35
with door open function
— u u — 3VA9277-0EK35
— — — u 3VA9447-0EK35
EMERGENCY-OFF with door interlock, Yellow-Red u — — — 3VA9137-0EK37
with door open function,
— u u — 3VA9277-0EK37
with illumination kit
— — — u 3VA9447-0EK37
Without handle, with shaft stub, Gray u — — — 3VA9137-0GK00
without door interlock
— u u — 3VA9277-0GK00
For retrofit with 3VL handle
— — — u 3VA9447-0GK00

7-74 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 07/31/19

3VA Molded Case Circuit Breakers


3VA Manual Operators Selection

Door Mounted Rotary Operatora


3VA5
3VA6 3VA6
3VA5 3VA5 150A 400A
Type Color 125A 250A 250A 600A Catalog Number
Standard Gray u — — — 3VA9137-0FK21
— u u — 3VA9277-0FK21
— — — u 3VA9447-0FK21
Standard with illumination kit Gray u — — — 3VA9137-0FK23
— u u — 3VA9277-0FK23
— — — u 3VA9447-0FK23
EMERGENCY-OFF Yellow-Red u — — — 3VA9137-0FK25
— u u — 3VA9277-0FK25
— — — u 3VA9447-0FK25
EMERGENCY-OFF Yellow-Red u — — — 3VA9137-0FK27
with illumination kit — u u — 3VA9277-0FK27
— — — u 3VA9447-0FK27
Standard with door interlock, Gray u — — — 3VA9137-0FK31
with open door function — u u — 3VA9277-0FK31
Degree of protection — — — u 3VA9447-0FK31
Type 1, 12, 3R and 4X Standard with door interlock, Gray u — — — 3VA9137-0FK33
with open door function — u u — 3VA9277-0FK33
with illumination kit — — — u 3VA9447-0FK33
EMERGENCY-OFF with door interlock, Yellow-Red u — — — 3VA9137-0FK35
with open door funtion — u u — 3VA9277-0FK35
— — — u 3VA9447-0FK35
EMERGENCY-OFF with door interlock, Yellow-Red u — — — 3VA9137-0FK37
with open door function, with — u u — 3VA9277-0FK37
illumination kit — — — u 3VA9447-0FK37
Standard Gray u — — — 3VA9137-0GC01
— u u — 3VA9477-0GC01
— — — u 3VA9477-0GC11
NFPA-79 EMERGENCY-OFF Yellow-Red u — — — 3VA9137-0GC05
Supplementary — u u — 3VA9477-0GC05
Handles — — — u 3VA9477-0GC15

Side Mounted Rotary Operatora


Standard Gray u — — — 3VA9137-0PK11
— u u — 3VA9277-0PK11

7
Standard with Gray u — — — 3VA9137-0PK13
illumination kit — u u — 3VA9277-0PK13

CIRCUIT BREAKERS
MOLDED CASE
EMERGENCY-OFF Yellow-Red u — — — 3VA9137-0PK15
— u u — 3VA9277-0PK15
n Without mounting plate EMERGENCY-OFF Yellow-Red u — — — 3VA9137-0PK17
n Rotary operator with shaft 300 mm with illumination kit — u u — 3VA9277-0PK17
n Handle with masking plate 75 x 75 mm
n Degree of protection
Type 1, 12, 3R and 4X
Standard with mounting plate Gray u — — — 3VA9137-0PK51
— u u — 3VA9277-0PK51
Standard with mounting plate, Gray u — — — 3VA9137-0PK53
with illumination kit — u u — 3VA9277-0PK53
EMERGENCY-OFF with Yellow-Red u — — — 3VA9137-0PK55
mounting plate — u u — 3VA9277-0PK55
n With mounting plate EMERGENCY-OFF with mounting Yellow-Red u — — — 3VA9137-0PK57
n Rotary operator with short shaft plate, with illumination kit — u u — 3VA9277-0PK57
n Handle with masking plate 75 x 75 mm
n Degree of protection
Type 1, 12, 3R and 4X
Standard for use with the side wall Gray u — — — 3VA9177-0VF40
mounted rotary operators — u u — 3VA9277-0VF40
n Without mounting plate
Side
Mounted
Rotary
Operator
Door
Interlock

a Lockable with up to three padlock hasps.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-75


Revised on 09/30/19

3VA Molded Case Circuit Breakers


3VA Manual Operators Selection

Handles with Masking Plate


3VA5
Tolerance Door 3VA6 3VA6
Compen- Open 3VA5 3VA5 150A 400A
Type Color sation Function 125A 250A 250A 600A Catalog Number
Standard Gray Without Without u u u — 8UD1721-0AB11
With Without u u u — 8UD1721-0AB21
Without Without — — — u 8UD1731-0AB11
With Without — — — u 8UD1731-0AB21
Without With u u u — 8UD1721-0AC11
With With u u u — 8UD1721-0AC21
Without With — — — u 8UD1731-0AC11
With With — — — u 8UD1731-0AC21
EMERGENCY- Yellow- Without Without u u u — 8UD1721-0AB15
OFF Red With Without u u u — 8UD1721-0AB25
n Degree of protection Without Without — — — u 8UD1731-0AB15
Type 1, 12, 3R and 4X With Without — — — u 8UD1731-0AB25
Without With u u u — 8UD1721-0AC15
With With u u u — 8UD1721-0AC25
Without With — — — u 8UD1731-0AC15
With With — — — u 8UD1731-0AC25

Metal Rotary Handles


3VA5
Tolerance Door 3VA6 3VA6
Compen- Open 3VA5 3VA5 150A 400A
Type Color sation Function 125A 250A 250A 600A Catalog Number

n Large, degree of protection Metal Black — With u u u u RHOH


Type 1, 3, 3R, 12
n Large, degree of protection
Metal Stainless — With u u u u RHOH4
Type 4, 4X
7

n Compact, degree of protection Compact Black — With u u u u RHOHC


Type 1,3,3R,12
MOLDED CASE
CIRCUIT BREAKERS

n Compact, degree of protection Compact Stainless — With u u u u RHOH4C


Type 4, 4X

n Long, degree of protection Emergency Red — With u u u u RHVPEMH


1,3,3R,12
n Compact, degree of protection
Emergency Red — With u u u u RHVMEMH
1,3,3R,12

7-76 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA Manual Operators Selection

Pistol Grip Handles


3VA5
Tolerance Door 3VA6 3VA6
Compen- Open 3VA5 3VA5 150A 400A
Type Color sation Function 125A 250A 250A 600A Catalog Number

n Degree of protection Plastic Gray — With u u u u 3VA9477-0FH11


Type 1,3R,12

n Degree of protection Emergency Red — With u u u u 3VA9477-0FH15


Type 1,3R,12

Door Mounted Rotary Operator Accessories


3VA5
3VA6 3VA6
3VA5 3VA5 150A 400A
Type 125A 250A 250A 600A Catalog Number
8 mm Shaft 300 mm long (for 8UD plastic handles) u u u u 8UD1900-2WA00
(Fixing bracket optional)
8 mm Shaft 600 mm long (for 8UD plastic handles) u u u u 8UD1900-2WB00
(Fixing bracket required)

8 mm shaft 300 mm long (for metal handles) u u u u 3VA9477-0GF20


(Fixing bracket optional)
8 mm shaft 600 mm long (for metal handles) u u u u 3VA9477-0GF21
(Fixing bracket required)

8 mm shaft 300 mm long (for pistol grip handles) u u u u 3VA9477-0GF10


(Fixing bracket optional)

7
8 mm shaft 600 mm long (for pistol grip handles) u u u u 3VA9477-0GF11
(Fixing bracket required)

CIRCUIT BREAKERS
MOLDED CASE
Adapter for Shaft for door mounted operator u u u u 8UD1900-2DA00

Door Coupling 8 mm x 8 mm u u u u 8UD1900-2HA00


(for 8UD plastic handles)

Fixing bracket for Shaft u — — — 3VA9137-0GA80

— u u u 3VA9477-0GA80

Variable depth adapter 8 x 8 mm u u u u 3VA9487-0GB10

Mounting tolerance compensation 8 x 8 mm u u u u 8UD1900-2GA00


(for 8UD plastic handles)

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-77


Revised on 07/31/19

3VA Molded Case Circuit Breakers


3VA Manual Operators Selection

General Accessories for Manual Operators


Type Details Part Number
Labeling plate for — 3VA9087-0SX10
manual operators

Illumination kit for For Molded Case Circuit Breakers


manual operators 3VA5, 125...250 A Front mounted rotary 8UD1900-0KA10
24 V DC voltage operators
3VA6, 150...600 A Front mounted rotary 8UD1900-0KA20
operators
3VA5, 3VA6, Door mounted rotary 8UD1900-0KA20
125...600 A operators

Cylinder Lock (type Kaba) Key 1 8UD1900-0MB01


n For 8UD plastic door mounted
Key 2 8UD1900-0NB01
rotary operators (in masking plate)
n Standard masking plate
Key 3 8UD1900-0PB01
Key 4 8UD1900-0QB01
Cylinder Lock (type Kaba)a Key 1 8UD1900-0MC01
n For 8UD plastic door mounted
Key 2 8UD1900-0NC01
rotary operators (in masking plate)
n Standard masking plate
Key 3 8UD1900-0PC01
Key 4 8UD1900-0QC01
Cylinder Lock (type Kaba) Key 1 8UD1900-0MB05
n For 8UD plastic door mounted
Key 2 8UD1900-0NB05
rotary operators (in masking plate)
n EMERGENCY-OFF masking plate
Key 3 8UD1900-0PB05
Key 4 8UD1900-0QB05
Cylinder Lock (type Kaba)a Key 1 8UD1900-0MC05
n For 8UD plastic door mounted
Key 2 8UD1900-0NC05
rotary operators (in masking plate)
n EMERGENCY-OFF masking plate
Key 3 8UD1900-0PC05
Key 4 8UD1900-0QC05
Cylinder Lock (type Ronis) Key 1 3VA9980-0VL10
n includes 2 keys
Key 3 3VA9980-0VL30
n for locking or interlocking

n installation in all rotary


Key 4 3VA9980-0VL40
operators w/ shaft stub
7

Cylinder lock adapter for 8UD rotary operator 3VA9980-0LF20


MOLDED CASE
CIRCUIT BREAKERS

n to mount in rotary operator

Variable depth flange mounted operator kit


3VA5
3VA6 3VA6
3VA5 3VA5 150A 400A
Type 125A 250A 250A 600A Catalog Number
Complete kit comprising: u — — — 3VA9138-0DK72
n Switching mechanism adjustable depth
— u u — 3VA9278-0DK72
200mm to 400mm
n Epoxy coated steel handle, NEMA 1/3R/12,
— — — u 3VA9478-0DK72
black = OFF, red = ON
Complete kit comprising: u — — — 3VA9138-0DK82
n Switching mechanism adjustable depth
— u u — 3VA9278-0DK82
200mm to 400mm
n Stainless steel handle, chrome-plated NEMA 4/4X,
— — — u 3VA9478-0DK82
black=OFF, red=ON
Complete kit comprising: u — — — 3VA9138-0DK84
n Swithching mechanism adjustable depth
— u u — 3VA9278-0DK84
200mm to 400mm
n Handle stainless steel, chrome-plated NEMA 4/4X,
— — — u 3VA9478-0DK84
black=OFF, black=ON

a With door open function

7-78 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 07/31/19

3VA Molded Case Circuit Breakers


3VA Manual and Motor Operators Selection

Max Flex Operator


3VA5
3VA6 3VA6
3VA5 3VA5 150A 400A
Type 125A 250A 250A 600A Catalog Number
Complete Kit u — — — 3VA9137-0CK12
n Switching mechanism
— u u — 3VA9277-0CK12
n Plastic handle, NEMA 1/12, black=OFF, green=ON

n Bowden Cable 36 inches (0.9m) long


— — — u 3VA9477-0CK12

Complete Kit u — — — 3VA9137-0CK72


n Switching mechanism
— u u — 3VA9277-0CK72
n Steel handle, epoxy coated NEMA 1/3R/12,
— — — u 3VA9477-0CK72
black=OFF, red=ON,
n Bowden Cable 36 inches (0.9m) long

Operating Mechanism (spare) u — — — 3VA9137-0CB10


— u u — 3VA9277-0CB10
Complete kit and spare mechanism — — — u 3VA9477-0CB10
Handle - Plastic, NEMA 1/12, u u u u 3VA9977-0CH12
black = OFF, green = ON
Handle - Steel, Epoxy coated, NEMA 1/3R/12, u u u u 3VA9977-0CH72
black = OFF, red = ON
Handle - Steel, Epoxy coated, NEMA 1/3R/12, u u u u 3VA9977-0CH74
black = OFF, black = ON
Handle - Steel, chrome-plated, NEMA 4/4X, u u u u 3VA9977-0CH82
black = OFF, red = ON
Handle - Steel, chrome-plated, NEMA 4/4X, u u u u 3VA9977-0CH84
black = OFF, black = ON
Bowden Cable, 36 inches (0.9m) u u u — 3VA9278-0CC10
Bowden Cable, 48 inches (1.2m) u u u — 3VA9278-0CC20
Bowden Cable, 60 inches (1.5m) u u u — 3VA9278-0CC30
Bowden Cable, 72 inches (1.8m) u u u — 3VA9278-0CC40
Bowden Cable, 84 inches (2.1m) u u u — 3VA9278-0CC50
Bowden Cable, 96 inches (2.4m) u u u — 3VA9278-0CC60
Bowden Cable, 120 inches (3.0m) u u u — 3VA9278-0CC70
Bowden Cable, 144 inches (3.6m) u u u — 3VA9278-0CC80
Bowden Cable, 36 inches (0.9m) — — — u 3VA9578-0CC10
Bowden Cable, 48 inches (1.2m) — — — u 3VA9578-0CC20
Bowden Cable, 60 inches (1.5m) — — — u 3VA9578-0CC30
Bowden Cable, 72 inches (1.8m) — — — u 3VA9578-0CC40

7
Bowden Cable, 84 inches (2.1m) — — — u 3VA9578-0CC50
Bowden Cable, 96 inches (2.4m) — — — u 3VA9578-0CC60

CIRCUIT BREAKERS
MOLDED CASE
Bowden Cable, 120 inches (3.0m) — — — u 3VA9578-0CC70
Bowden Cable, 144 inches (3.6m) — — — u 3VA9578-0CC80
MaxFlex Auxiliary switch u u u u 3VA9478-0CX10
(leading from On to Off)
n 1 CO

MaxFlex Auxiliary switch u u u u 3VA9478-0CX20


(leading from On to Off)
n 2 CO

Motor Operator without Stored Energy Featurea


3VA5
3VA6 3VA6
3VA5 3VA5 150 A 400A
Type 125 A 250 A 250 A 600A Part Number
24 ... 60 V DC u — — — 3VA9137-0HA10
— u u — 3VA9277-0HA10
— — — u 3VA9447-0HA10
110 ... 230 V AC u — — — 3VA9137-0HA20
110 ... 250 V DC — u u — 3VA9277-0HA20
— — — u 3VA9447-0HA20

a Lockable with up to three padlock hasps.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-79


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA Connection Technology Selection

Box Terminals
For molded case circuit breakers/
Minimum Maximum rated current
cable cross- cable cross- 3VA5
section section 3VA6 3VA6
(standard) (standard) 3VA5 3VA5 150A 400A
Type Class B Class B 125A 250A 250A 600A Part Number
Steel wrap-around lug AWG 14 3/0 u — — — 3VA9133-0JA11
(Cu cable only) AWG 10 3/0 — u — — 3VA9233-0JA11
kit of 3 single lugs
AWG 4 350 kcmil — u — — 3VA9233-0JA12
AWG 10 3/0 — — u — 3VA9143-0JA12
AWG 4 350 kcmil — — u — 3VA9243-0JA12
1/0 500 kcmil — — — u 3VA9473-0JA13
Steel wrap-around lug AWG 14 AWG 10 u — — — 3VA9134-0JA11
(Cu cable only) AWG 10 3/0 — — u — 3VA9144-0JA12
kit of 4 single lugs
AWG 4 350 kcmil — — u — 3VA9244-0JA12
1/0 500 kcmil — — — u 3VA9474-0JA13

Aluminum Wire Connectors


For molded case circuit breakers/
Minimum Maximum rated current
cable cross- cable cross- 3VA5
section section 3VA6 3VA6
(standard) (standard) 3VA5 3VA5 150A 400A
Type Class B Class B 125A 250A 250A 600A Part Number
Aluminum body lug AWG 14 AWG 10 u — — — 3VA9133-0JB10
small (Cu/Al cable)
kit of 3 single lugs
Aluminum body lug AWG 14 3/0 u — — 3VA9133-0JB11
(Cu/Al cable) AWG 6 350 kcmil — u — — 3VA9233-0JB12b
kit of 3 single lugs
AWG 14 1/0 — — u — 3VA9143-0JB11b
AWG 6 350 kcmil — — u — 3VA9243-0JB12
AWG 1 600 kcmil — — — u 3VA9373-0JB13a
Aluminum body lug AWG 14 AWG 10 u — — — 3VA9134-0JB10
small (Cu/Al cable)
kit of 4 single lugs

Aluminum body lug AWG 14 AWG 10 u — — — 3VA9134-0JB11


(Cu/Al cable)
7

AWG 14 1/0 — — u — 3VA9144-0JB11b


kit of 4 single lugs
AWG 6 350 kcmil — — u — 3VA9244-0JB12b
AWG 1 600 kcmil — — — u 3VA9374-0JB13a
MOLDED CASE
CIRCUIT BREAKERS

Aluminum body lug AWG 14 AWG 10 u — — — 3VA9133-0JG10


small with control wire
tap (Cu/Al cable)

Aluminum body lug AWG 14 3/0 u — — 3VA9133-0JG11


with control wire tap AWG 6 350 kcmil — u — — 3VA9233-0JG12
(Cu/Al cable)
AWG 14 1/0 — — u — 3VA9143-0JG11b
kit of 3 single lugs
AWG 6 350 kcmill — — u — 3VA9243-0JG12b
AWG 1 600 kcmil — — — u 3VA9373-0JG13a
Aluminum body lug AWG 14 AWG 10 u — — — 3VA9134-0JG10
small with control wire
tap (Cu/Al cable)

Aluminum body lug with AWG 14 AWG 10 u — — — 3VA9134-0JG11


control wire tap (Cu/Al AWG 14 1/0 — — u — 3VA9144-0JG11b
cable) kit of 4 single lugs
AWG 6 350 kcmil — — u — 3VA9244-0JG12b
AWG 1 600 kcmil - - - u 3VA9374-0JG13a

aThis conductor is ampere-rated at 380A with copper


wire and 310A with aluminum wire.
bMeets requirements of 100% rated breakers up to 150A.

7-80 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA Connection Technology Selection

Aluminum Wire Connectors (cont.)


Minimum Maximum For molded case circuit
cable cable breakers/rated current
cross- cross- 3VA5
section section 3VA6 3VA6 Terminal Cover
(standard) (standard) 3VA5 3VA5 150A 400A with Probe Holes
Type Class B Class B 125A 250A 250A 600A Part Number Part Number
Aluminum body lug large AWG 4 350 kcmil u — — — 3VA9133-0JJ12
(Cu/Al cable)
kit of 3 single lugs and AWG 2 350 kcmil — u — — 3VA9233-0JJ13
1 extended terminal cover
AWG 2 350 kcmil — — u — 3VA9243-0JJ13a

Aluminum body lug large AWG 2 350 kcmil — — u — 3VA9244-0JJ13a


(Cu/Al cable)
kit of 4 single lugs and
3 lug 4 lug 1 extended terminal cover
Aluminum body lug large AWG 4 350 kcmil u — — — 3VA9133-0JC12 3VA9133-0JC18
with control wire tap AWG 2 350 kcmil — u — — 3VA9233-0JC13 3VA9233-0JC18
(Cu/Al cable)
AWG 2 350 kcmil - - u - 3VA9243-0JC13a 3VA9243-0JC18
kit of 3 single lugs and
1 extended terminal cover

Aluminum body lug large AWG 4 300 kcmil u — — — 3VA9134-0JC12


with control wire tap
(Cu/Al cable)
kit of 4 single lugs and AWG 2 350 kcmil — — u — 3VA9244-0JC13a
1 extended terminal cover
3 lug 4 lug
Aluminum body lug, AWG 4 300 kcmil — u — — 3VA9233-0JJ22
2 Cables (Cu/Al cable) AWG 4 300 kcmil — — u — 3VA9243-0JJ22a
kit of 3 single lugs and
2/0 600 kcmil - - - u 3VA9473-0JJ23
1 extended terminal cover

Aluminum body lug, AWG 4 300 kcmil — — u — 3VA9244-0JJ22a


2 Cables (Cu/Al cable) 2/0 600 kcmil - - - u 3VA9474-0JJ23
kit of 4 single lugs and
1 extended terminal cover

3 lug 4 lug

Aluminum body lug, AWG 4 300 kcmil — u — — 3VA9233-0JC22 3VA9233-0JC28

7
2 Cables with control wire AWG 4 300 kcmil — — u — 3VA9243-0JC22a 3VA9243-0JC28
tap (Cu/Al cable)
2/0 600 kcmil - - - u 3VA9473-0JC23 3VA9473-0JC28
kit of 3 single lugs and

CIRCUIT BREAKERS
MOLDED CASE
1 extended terminal cover

Aluminum body lug, AWG 4 300 kcmil — — u — 3VA9244-0JC22a


2 Cables with control wire 2/0 600 kcmil — — — u 3VA9474-0JC23
tap (Cu/Al cable)
kit of 4 single lugs and
3 lug 4 lug 1 extended terminal cover

Distribution lug, AWG 14 AWG 2 u — — — 3VA9133-0JF60 3VA9133-0JF68


6 Cables (Cu/Al cable) AWG 2 — u — — 3VA9233-0JF60 3VA9233-0JF68
kit of 3 single lugs and
AWG 2 — — u — 3VA9243-0JF60b 3VA9243-0JF68
1 extended terminal cover
AWG 2 — — — u 3VA9373-0JF60c 3VA9373-0JF68

Distribution lug, AWG 14 AWG 2 u — — — 3VA9134-0JF60


6 Cables (Cu/Al cable) AWG 2 — — u — 3VA9244-0JF60b
kit of 4 single lugs and
AWG 2 — — — u 3VA9374-0JF60c
1 extended terminal cover
3 lug 4 lug

a Meets requirements of 100% rated breakers up to 250A.


b Meets requirements of 100% rated breakers up to 100A.
c Meets requirements of 100% rated breakers up to 100A.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-81


Revised on 05/31/19

3VA Molded Case Circuit Breakers


3VA Connection Technology Selection

Copper Wire Connectors


For molded case circuit breakers/
Minimum Maximum rated current
cable cross- cable cross- 3VA5
section section 3VA6 3VA6
(standard) (standard) 3VA5 3VA5 150A 400A
Type Class B Class B 125A 250A 250A 600A Part Number
Copper body lug AWG 14 AWG 10 u — — 3VA9133-0JD10
small (Cu cable only)
kit of 3 single lugs

Copper body lug AWG 14 2/0 u — — 3VA9133-0JD11


(Cu cable only) AWG 6 350 kcmil — u — — 3VA9233-0JD12
kit of 3 single lugs
AWG 14 1/0 — — u — 3VA9143-0JD11
AWG 6 350 kcmil — — u — 3VA9243-0JD12
AWG 1 600 kcmil — — — u 3VA9373-0JD13
Copper body lug AWG 14 AWG 10 u — — 3VA9134-0JD10
small (Cu cable only)
kit of 4 single lugs

Copper body lug AWG 14 AWG 10 u — — 3VA9134-0JD11


(Cu cable only) AWG 14 1/0 — — u — 3VA9144-0JD11
kit of 4 single lugs
AWG 6 350 kcmil — — u — 3VA9244-0JD12
AWG 1 600 kcmil — — — u 3VA9374-0JD13
Copper body lug AWG 14 AWG 10 u — — 3VA9133-0JK10
small with control wire
tap (Cu cable only)
kit of 3 single lugs

Copper body lug AWG 14 2/0 u — — 3VA9133-0JK11


with control wire tap AWG 6 350 kcmil — u — — 3VA9233-0JK12
(Cu cable only)
AWG 14 1/0 — — u — 3VA9143-0JK11
kit of 3 single lugs
AWG 6 350 kcmil — — u — 3VA9243-0JK12
AWG 1 600 kcmil — — — u 3VA9373-0JK13
Copper body lug AWG 14 AWG 10 u — — 3VA9134-0JK10
small with control wire
tap (Cu cable only)
kit of 4 single lugs
7

Copper body lug AWG 14 AWG 10 u — — 3VA9134-0JK11


with control wire tap
MOLDED CASE
CIRCUIT BREAKERS

AWG 14 1/0 — — u — 3VA9144-0JK11


(Cu cable only)
AWG 6 350 kcmil — — u — 3VA9244-0JK12
kit of 4 single lugs
AWG 1 600 kcmil - - - u 3VA9374-0JK13
Copper body lug 2/0 600 kcmil — — — u 3VA9473-0JE23
2 Cables (Cu cable only)
kit of 3 single lugs and
1 extended terminal cover

Copper body lug 2 Cables 2/0 600 kcmil — — — u 3VA9474-0JE23


(Cu cable only) kit of 4
single lugs and 1 extend-
ed terminal cover

Copper body lug 2 Cables 2/0 600 kcmil — — — u 3VA9473-0JL23


with control wire tap
(Cu cable only)
kit of 3 single lugs and
1 extended terminal cover
Copper body lug 2 Cables 2/0 600 kcmil — — — u 3VA9474-0JL23
with control wire tap
(Cu cable only)
kit of 4 single lugs and
1 extended terminal cover

7-82 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/19

3VA Molded Case Circuit Breakers


3VA Connection Technology Selection

Nut Keeper Kits


For molded case circuit breakers/
rated current
3VA5
Maximum Maximum 3VA6 3VA6
terminal terminal 3VA5 3VA5 150A 400A
Type width thickness 125A 250A 250A 600A Part Number
Nut keeper kit 6.5 mm /0.25 inch 17 mm / 0.7 inch u — — — 3VA9133-0QA00
kit of 3 single lugs 8 mm / 0.3 inch 25 mm / 1 inch — u — — 3VA9233-0QA00
8 mm / 0.3 inch 25 mm / 1 inch — — u — 3VA9243-0QA00
10 mm / 0.4 inch 35 mm / 1.4 inch — — — u 3VA9473-0QA00
Nut keeper kit 6.5 mm /0.25 inch 17 mm / 0.7 inch u — — — 3VA9134-0QA00
kit of 4 single lugs 8 mm / 0.3 inch 25 mm / 1 inch — — u — 3VA9244-0QA00
10 mm / 0.4 inch 35 mm / 1.4 inch — — — u 3VA9474-0QA00

Bus Connector Extensions


For molded case circuit breakers/
rated current
3VA5
Maximum Maximum 3VA6 3VA6
terminal terminal 3VA5 3VA5 150A 400A
Type width thickness 125A 250A 250A 600A Part Number
Front bus connectors 22 mm / 8 mm / u — — — 3VA9131-0QB00
extended 1 single connector 0.9 inch 0.3 inch

Front bus connectors 22 mm / 8 mm / u — — — 3VA9133-0QB00


extended kit of 3 single connectors, 0.9 inch 0.3 inch
2 phase barriers, and 1 insulating
plate

Front bus connectors 22 mm / 8 mm / u — — — 3VA9133-0QB00


extended kit of 4 single connectors, 0.9 inch 0.3 inch
3 phase barriers, and 1 insulating
plate

7
CIRCUIT BREAKERS
MOLDED CASE
Front bus connectors 32 mm / 10 mm / — u u — 3VA9273-0QB00
extended kit of 3 single connectors 1.3 inch 0.4 inch
and 1 insulating plate 40 mm / 12.5 mm / — — — u 3VA9473-0QB00
1.6 inch 0.5 inch

Front bus connectors 32 mm / 10 mm / — — u — 3VA9274-0QB00


extended kit of 4 single connectors 1.3 inch 0.4 inch
and 1 insulating plate 40 mm / 12.5 mm / — — — u 3VA9474-0QB00
1.6 inch 0.5 inch

Front bus connectors 60 mm / 12.5 mm / — — — u 3VA9473-0QC00


offset kit of 3 single connectors 2.4 inch 0.5 inch
1 insultating plate
Distance between pole centers:
400/600 A = 70 mm / 2.76 inches

Front bus connectors 60 mm / 12.5 mm / 3VA9474-0QC00


offset kit of 4 single connectors 2.4 inch 0.5 inch
1 insultating plate
Distance between pole centers: — — — u
400/600 A = 70 mm / 2.76 inches

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-83


Revised on 05/31/19

3VA Molded Case Circuit Breakers


3VA Connection Technology Selection

Rear connection studs flat


For molded case circuit breakers
/ rated current
3VA5
3VA6 3VA6
3VA5 3VA5 150A 400A
Type 125A 250A 250A 600A Part Number
Rear connection studs flat u — — — 3VA9133-0QE00
kit of 2 short flat studs and — u — — 3VA9233-0QE00
1 long flat stud
— — u — 3VA9243-0QE00
— — — u 3VA9473-0QE00
Rear connection studs flat u — — — 3VA9134-0QE00
kit of 2 short flat studs and — — u — 3VA9244-0QE00
2 long flat studs
— — — u 3VA9474-0QE00

Rear connection studs flat u — — — 3VA9131-0QE10


1 short flat stud — u — — 3VA9231-0QE10
— — u — 3VA9241-0QE10
— — — u 3VA9471-0QE10
Rear connection studs flat u — — — 3VA9131-0QE20
1 long flat stud — u — — 3VA9231-0QE20
— — u — 3VA9241-0QE20
— — — u 3VA9471-0QE20

Rear connection studs round


Rear connection studs round u — — — 3VA9133-0QF00
kit of 1 long round stud and — u — — 3VA9233-0QF00
2 short round studs
— — u — 3VA9243-0QF00
— — — u 3VA9473-0QF00

Rear connection studs round u — — — 3VA9134-0QF00


kit of 2 long round studs and — — u — 3VA9244-0QF00
2 short round studs
— — — u 3VA9474-0QF00
7

Rear connection studs round u — — — 3VA9131-0QF10


1 short round studs — u — — 3VA9231-0QF10
MOLDED CASE
CIRCUIT BREAKERS

— — u — 3VA9241-0QF10
— — — u 3VA9471-0QF10

Rear connection studs round u — — — 3VA9131-0QF20


1 long round stud — u — — 3VA9231-0QF20
— — u — 3VA9241-0QF20
— — — u 3VA9471-0QF20

7-84 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 11/30/19

3VA Molded Case Circuit Breakers


3VA Connection Technology Selection

Phase barriers, terminal covers, and insulating plates


For molded case circuit breakers
/ rated current
3VA5
3VA6 3VA6 Terminal Cover
3VA5 3VA5 150A 400A with Probe Holes
Type 125A 250A 250A 600A Part Number Part Number
Phase barriers u — — — 3VA9132-0WA00
kit of 2 phase barriers
— u u — 3VA9272-0WA00
— — — u 3VA9472-0WA00

Terminal cover for u — — — 3VA9131-0WD10


1-pole breakers

Terminal cover for u — — — 3VA9131-0WD20


2-pole breakers

Terminal cover for u — — — 3VA9131-0WD30 3VA9131-0WD31


3-pole breakers — u u — 3VA9271-0WD30 3VA9271-0WD31
— — — u 3VA9471-0WD30 3VA9471-0WD31
Terminal cover for u — — — 3VA9131-0WD40
4-pole breakers — — u — 3VA9271-0WD40
— — — u 3VA9471-0WD40
Terminal cover extended for u — — — 3VA9131-0WF20
2-pole breakers

Terminal cover extended for u — — — 3VA9131-0WF30 3VA9131-0WF31


3-pole breakers — u u — 3VA9271-0WF30 3VA9271-0WF31
— — — u 3VA9471-0WF30 3VA9471-0WF31

7
CIRCUIT BREAKERS
MOLDED CASE
Terminal cover extended for u — — — 3VA9131-0WF40
4-pole breakers — — u — 3VA9271-0WF40
— — — u 3VA9471-0WF40

Terminal cover offset for — — — u 3VA9471-0WG30


3-pole breakers

Terminal cover offset for 4-pole — — — u 3VA9471-0WG40


breakers

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-85


Revised on 05/31/19

3VA Molded Case Circuit Breakers


3VA Connection Technology Selection

Phase barriers, terminal covers, and insulating plates


For molded case circuit breakers
/ rated current
3VA5
3VA6 3VA6
3VA5 3VA5 150A 400A
Type 125A 250A 250A 600A Part Number
Rear insulating plate extended for 2-pole breakers u — — — 3VA9131-0WJ20

Rear insulating plate extended for 3-pole breakers u — — — 3VA9131-0WJ30


— u u — 3VA9271-0WJ30
— — — u 3VA9471-0WJ30

Rear insulating plate extended for 4-pole breakers u — — — 3VA9131-0WJ40


— — u — 3VA9271-0WJ40
— — — u 3VA9471-0WJ40

Rear insulating plate offset for 3-pole breakers — — — u 3VA9471-0WK30


7

Rear insulating plate offset for 4-pole breakers — — — u 3VA9471-0WK40


MOLDED CASE
CIRCUIT BREAKERS

Control wire tap for busbar — u u — 3VA9270-0WC00


(for fixed mounting) — — — u 3VA9470-0WC00

7-86 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 10/31/18

3VA Molded Case Circuit Breakers


3VA Plug-in and Draw-out Technology Selection

Plug-in socket
For molded case circuit breakers /
rated current
3VA61/62 3VA63 3VA64
Type 150A/250A 400A 600A Part Number
Plug-in unit, 3-pole, complete kit u — — 3VA9143-0KP00
Consists of: Plug-in socket, Plug-in unit, — u — 3VA9343-0KP00
conversion kit, Mounting screw kit
— — u 3VA9443-0KP00

Plug-in unit, 4-pole, complete kit u — — 3VA9144-0KP00


Consists of: Plug-in socket, Plug-in unit, — u — 3VA9344-0KP00
conversion kit, Mounting screw kit
— — u 3VA9444-0KP00

3 pole 4 pole

Plug-in unit, 3-pole, conversion kit u — — 3VA9143-0KP10


Consists of: Screw-fastened terminal — u u 3VA9343-0KP10
covers for molded case circuit breakers,
Plug-in contacts, Cable cage, Autotrip plunger

Plug-in unit, 4-pole, conversion kit u — — 3VA9144-0KP10


Consists of: Screw-fastened terminal — u u 3VA9344-0KP10
covers for molded case circuit breakers,
Plug-in contacts, Cable cage, Autotrip plunger

3 pole 4 pole

Draw-out units
For molded case circuit breakers /
rated current
3VA61/62 3VA63 3VA64
Type 150A/250A 400A 600A Part Number
Draw-out unit, 3-pole, complete kit u — — 3VA9143-0KD00
Consists of: Draw-out socket, Draw-out unit, conversion — u — 3VA9343-0KD00

7
kit, Mounting screw kit
— — u 3VA9443-0KD00

CIRCUIT BREAKERS
MOLDED CASE
Draw-out unit, 4-pole, complete kit u — — 3VA9144-0KD00
Consists of: Draw-out socket, Draw-out unit, — u — 3VA9344-0KD00
conversion kit, Mounting screw kit
— — u 3VA9444-0KD00

Draw-out unit, 3-pole, conversion kit u — — 3VA9143-0KD10


Consists of: Screw-fastened terminal covers, — u u 3VA9343-0KD10
Side wall, Plug-in contacts, Cable cage, Autotrip plunger

Draw-out unit, 4-pole, conversion kit u — — 3VA9144-0KD10


Consists of: Screw-fastened terminal covers, — u u 3VA9344-0KD10
Side wall, Plug-in contacts, Cable cage, Autotrip plunger

3 pole 4 pole

Note: Crank handle for the drawout unit must be ordered seperately.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-87


Revised on 10/31/18

3VA Molded Case Circuit Breakers


3VA Plug-in and Draw-out Technology Selection

Accessories
For molded case circuit breakers /
rated current
3VA61/62 3VA63/64
Type 150A/250A 400A/600A Part Number
Cable cage for plug-in/draw-out unit 3-/4- u — 3VA9167-0KB02
pole (spare part) Cable duct for routing of
the required cables from the internal acc.
on the back of the breaker.
— u 3VA9367-0KB02

Door feedthrough u — 3VA9147-0KT00

— u 3VA9347-0KT00

Autotrip plunger u — 3VA9267-0KP81


Plug-in unit
— u 3VA9457-0KP81

Autotrip plunger u — 3VA9267-0KD81


Draw-out unit
— u 3VA9457-0KD81

Terminal cover for plug-in/draw-out unit, u — 3VA9143-0KB01


3-pole (spare part) To provide circuit breaker
touch protection, for mounting on the
molded case cicuit breaker
— u 3VA9343-0KB01

Terminal cover for plug-in/draw-out unit, u — 3VA9144-0KB01


4-pole (spare part) To provide circuit breaker
touch protection, for mounting on the
molded case cicuit breaker
7

— u 3VA9344-0KB01
MOLDED CASE
CIRCUIT BREAKERS

Crank handle for draw-out unit 3VA9987-0KD81


Insulated, including crank holder

7-88 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/19

3VA Molded Case Circuit Breakers


3VA Plug-in and Draw-out Technology Selection

Other Accessories
Type Part Number
Communication link for draw-out unit 3VA9977-0KC00
Consists of: Cable kit with 3 special position signaling switches,
connecting cable 3VA9987-0KC10

Position signaling switches 3VA9977-0KB00


For draw-out unit

Spare connecting cable 3VA9987-0KC10


To connect the position signaling switches for
communication with the COM060

Auxiliary circuit connector 3VA9977-0KD80


n For draw-out units

Auxiliary circuit connector 3VA9977-0KP80

7
n For plug-in units

CIRCUIT BREAKERS
MOLDED CASE
Cylinder lock (type Ronis) 3VA9980-0VL10
n Includes a lock with 2 keys
3VA9980-0VL30
n For locking

n For installation in all rotary operators with shaft stub


3VA9980-0VL40
n For mounting in the adapter kit for the accessories component

Cylinder lock adapter for draw-out unit 3VA9970-0LF40


n For fitting a cylinder lock in the right-hand side wall of the draw-out unit

n To prevent unauthorized withdrawl or insertion of the circuit breaker;

n Circuit breaker can be locked in the CONNECT, TEST, or DISCONNECT position

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-89


Revised on 10/31/18

3VA Molded Case Circuit Breakers


3VA UL Molded Case Circuit Breakers
Accessories and Spare Parts
3VA Communication and Testing/Commissioning Devices Selection
Communication and testing/commissioning devices
Communications overview
■ Design

powermanager power powerconfig


monitoring software software

PROFIBUS

I201_19498
Ethernet (Modbus TCP)

SIMATIC S7

PROFINET

3VA-line

T-Connector T-Connector

4
7

COM800 DSP800
breaker data server display
MOLDED CASE
CIRCUIT BREAKERS

3VA6 molded case 3VA6 molded case


circuit breaker circuit breaker

COM060 7KM PAC Switched 7KM PAC 7KM PAC RS485


communication module Ethernet PROFINET PROFIBUS DP MODBUS RTU
expansion module expansion module expansion module

7-90 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/19

3VA Molded Case Circuit Breakers


3VA Communication and Testing/Commissioning Devices Selection

Modules
For molded case circuit
breakers / rated current
3VA61/62 3VA63/64
Type 150A/250 A 400A/600A Part Number
24 V Module u — 3VA9177-0TB50
n 24 V DC
— u 3VA9377-0TB50
n For mounting in the right-hand accessories compartment

of the 3VA6
n Optional energy supply for the ETU, also includes contiunous

operation of the ETU display and the metering function


of the ETU 8-series
COM060 communication module u — 3VA9177-0TB10
n For mounting in the right-hand accessories compartment of the
— u 3VA9377-0TB10
3VA6 molded case circuit breaker (including ETU power supply)
n Communication with the COM800/COM100 breaker data

server via the 3VA-line


n Including a T-Connector

Spare SLC adapter COM060, u — 3VA9187-0TB60


24 V module accessory for:
n 3VA61/62 100/150/250

Spare SLC adapter COM060, — u 3VA9387-0TB60


24 V module accessory for:
n 3VA63/64 400/600

Breaker data server


Type Part Number
COM800 breaker data server 3VA9977-0TA10
n 2 terminating resistors

n Central communication module for connecting up to eight 3VA6 molded

case circuit breakers via the 3VA-line


n Ethernet 10/100 Mbit/s interface

n Module slot for plugging on an optional PROFIBUS DP, PROFINET

or RS485 module

COM100 breaker data server 3VA9977-0TA20

7
n 2 terminating resistors

n Central communication module for connecting one 3VA6 molded

case circuit breaker

CIRCUIT BREAKERS
MOLDED CASE
n Ethernet 10/100 Mbit/s interface

n Module slot for plugging on an optional PROFIBUS DP, PROFINET

or RS485 module

7KM PAC PROFIBUS DP expansion module 7KM9300-0AB01-0AA0


n The 7KM PAC PROFIBUS DP expansion module is used for connecting

the COM800/COM100 breaker data server, and the 3VA molded case circuit
breakers conneccted to it, to PROFIBUS DPV1
n The 7KM PAC PROFIBUS DP expansion module provides the status and measured

quantities of the 3VA molded case circuit breaker for the PROFIBUS DP master.
It receives information (e.g. commands) from the PROFIBUS DP master, and
forwards this information to the 3VA molded case circuit breaker
7KM PAC Switched Ethernet PROFINET expansion module 7KM9300-0AE01-0AA0
n The 7KM PAC Switched Ethernet PROFINET expansion module is used to connect

the COM800/COM100 breaker data server, and the connected 3VA molded case
circuit breaker, to PROFINET via two Ethernet interfaces
n The 7KM PAC Switched Ethernet PROFINET expansion module provides the status

and measured quantities of the 3VA molded case circuit breaker to PROFINET via
the PROFINET IO, PROFIenergy and Modbus TCP protocols

7KM PAC RS485 Modbus RTU expansion module 7KM9300-0AM00-0AA0


n The 7KM PAC RS485 Modbus expansion module is used to connect the COM800/

COM100 breaker data server, and the 3VA molded case circuit breaker connected
to it, to Modbus RTU
n The 7KM PAC RS485 Modbus expansion module provides the status and measured

quantities of the 3VA molded case circuit breaker for the Modbus RTU master.
It receives information (e.g. commands) from the Modbus RTU master, and forwards
this information to the 3VA molded case circuit breaker

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-91


Revised on 02/28/19

3VA Molded Case Circuit Breakers


3VA Communication and Testing/Commissioning Devices Selection

Accessories for Communication


Type Part Number
T-Connector 3VA9987-0TG10
n Spare part

n Provides spur line feeder to COM060 and loops to the nextcircuit breaker

n Includes a connection adapter for mounting on the 3VA6 breaker enclosure

DIN rail adapter 3VA9987-0TG11


For snapping the T-Connector onto a DIN rail

Preassembled T-Connector-to-T-Connector or
T-Connector-to-COM800/ COM100 connecting cable
n 0.4 m long 3VA9987-0TC10
n 1 m long 3VA9987-0TC20
n 2 m long 3VA9987-0TC30
n 4 m long 3VA9987-0TC40

Preassembled connecting cable for extending the


COM060-to-T-Connector spur line connection
n 0.4 m long 3VA9987-0TF20
n 0.8 m long 3VA9987-0TF10

Additional bus terminating resistors 3VA9987-0TE10

Voltage tap to external N conductor 3VA9987-0UC10


Cable for connecting the neutral point for the metering function of the
8-Series ETU, length 1.5 m

External current transformer as straight-through transformer. Connection of an external current


7

transformer for the N conductor for 3-pole 3VA6 molded case circuit breakers for 5-series and
8-series ETUs (ETU850, ETU856, ETU860), including connecting cable
MOLDED CASE
CIRCUIT BREAKERS

n In = 25 ... 150A 3VA9077-0NA10


n In = 160 ... 350 A 3VA9177-0NA10
n In = 400 ... 630 A 3VA9377-0NA10

DSP800 display 3VA9977-0TD10


n For displaying the status, measured values and parameters of up to 8

3VA6 molded cases circuit breakers


n Connection to the COM800/COM100 via Ethernet for displaying information

of the COM800/COM100 and the connected 3VA6 molded case circuit breaker

EFB300 3VA9977-0UA10
n External function box for connection to the ETU of the 3VA6 molded case circuit breaker

n 4 digital outputs for information output, 1 digital input

n ZSI functionality

n S0 interface

n Including cable 1.5 m in length

Connecting cable for EFB300 and MMB300. Spare part


n 1.5 m long 3VA9987-0UB10
n 3.0 m long 3VA9987-0UB20
n 3.0 m long for 3VA with EFB and RCD820 3VA9987-0UB30

7-92 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/28/19

3VA Molded Case Circuit Breakers


3VA Communication and Testing/Commissioning Devices Selection

Test devices
Type Part Number
TD300 3VA9977-0MA10
n Connection to the front interface of the ETU

n Test device for activating the ETU and triggering a test trip

TD500 3VA9977-0MB10
n Connection to the front interface of the ETU

n Initiation of various test trips (LSING)

n USB interface for connection of a PC using powerconfig

n ETU parameterization

n Including external power supply unit with adapter for Europe, UL and GB

n Including connecting cable to the 3VA6 molded case circuit breaker

Spare part: External power supply for TD500 3VA9987-0MX10


110 ... 240 V AC

7
CIRCUIT BREAKERS
MOLDED CASE
Spare part: Cable for connecting to the TD500 to the 3VA6 molded 3VA9977-0MY10
case circuit breaker

Maintenance Mode Box


MMB300 3VA9977-0UF10
n Realization of the NEC 240.87 (Arc Energy Reduction) -> personal protection

during maintenance work


n Switch into maintenance mode by changing the I- and G-protection

to the lowest possible value through an external signal (e.g. door contact)
n Available for all 3VA6 circuit breakers with electronic trip unit

n Daisy chain up to 8 circuit breakers equipped with MMB300

n Additional digital output (D01) for ETU signals available

n Capable of DIN rail mounting

n Includes cable 1.5m in length

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-93


Revised on 01/31/20

3VA Molded Case Circuit Breakers


3VA Accessories for Locking, Blocking and Interlocking Selection

Locking, Blocking, & Interlocking


For molded case circuit breakers/
rated current
3VA5
3VA6 3VA6
3VA4 3VA5 3VA5 150A 400A
Type 125A 125A 250A 250A 600A Part Number
Blocking device for the handle u — — — 3VA9038-0LB10
— u u u 3VA9378-0LB10

Padlock device for the handle u — — — — 3VA9038-0LB11


— — u u — 3VA9138-0LB11
— — — — u 3VA9338-0LB11

3VA5/3VA6 3VA4
Adapter kit for mounting the cylinder lock u — — — 3VA9137-0LF10
(type Ronis) in the accessories compartment — u — — 3VA9237-0LF10
of the molded case circuit breaker
— — u — 3VA9147-0LF10
Comprising 2 cylinder lock casings (one for locking
and one for interlocking) and the appropriate mounting — — — u 3VA9347-0LF10
module
n To implement an interlock or a lock: select suitable cyl-

inder lock(s)
n For an interlock: select the same cylinder lock number

Cylinder lock (type Ronis)


n Includes a lock with 2 keys

n For locking or interlocking

n For installation in all rotary operators with shaft stub

n For mounting in the adapter kit for the accessories

compartment
7

n Key 1 (lock number 1) u u u u 3VA9980-0VL10


n Key 3 (lock number 3) u u u u 3VA9980-0VL30
MOLDED CASE
CIRCUIT BREAKERS

n Key 4 (lock number 4) u u u u 3VA9980-0VL40


Sliding bar u — — — 3VA9138-0VF30
Complete kit for interlocking 2 circuit breakers — u — — 3VA9238-0VF30
n The article number must be ordered 2X to implement
— — u — 3VA9148-0VF30
an interlock between 3 breakers of the same size
— — — u 3VA9348-0VF30

Module for handle interlock using a bowden cable u — — — 3VA9137-0VF10


n A seperate handle interlock module is required for
— u — — 3VA9237-0VF10
each switching device
n A Bowden cable must be ordered seperately
— — u — 3VA9147-0VF10
— — — u 3VA9347-0VF10

Rear interlock with rod u u u u 3VA9078-0VM10


Complete Kit
n Mounting frames are not included in scope of supply

Rear interlock with rod u u u u 3VA9078-0VM30


Complete Kit for plug-in/draw-out unit
n Mounting frames are not included in scope of supply

7-94 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/28/19

3VA Molded Case Circuit Breakers


3VA Accessories for Locking, Blocking and Interlocking Selection

Locking, Blocking, & Interlocking


For molded case circuit break-
ers/rated current
3VA5
3VA6 3VA6
3VA5 3VA5 150A 400A
Type 125A 250A 250A 600A Part Number
Bowden cable
n Length 0.6 m u u u u 3VA9980-0VC10
n Length 1.0 m u u u u 3VA9980-0VC20
n Length 1.5 m u u u u 3VA9980-0VC30

Mounting frame for rear interlock with rodab


The following are required for the complete
mounting frame kit:
n Profile poles u u u u 3VA9078-0VK10
n Mounting Plates u — — — 3VA9138-0VK20
— u — — 3VA9238-0VK20
— — u — 3VA9248-0VK20
— — — u 3VA9448-0VK20

Cover frame for door cut-out


Cover frame for door cut-out for molded u — — — 3VA9033-0SB10
case circuit breaker — u u — 3VA9143-0SB10
n 3-pole, door cut-out without trip unit
— — — u 3VA9373-0SB10
Cover frame for door cut-out for molded u — — — 3VA9033-0SB20
case circuit breaker — u — — 3VA9233-0SB20
n 3-pole, door cut-out with trip unit
— — u — 3VA9143-0SB20
— — — u 3VA9343-0SB20
Cover frame for door cut-out for molded u — — — 3VA9034-0SB10
case circuit breaker — u u — 3VA9144-0SB10
n 4-pole, door cut-out without trip unit
— — — u 3VA9374-0SB10
Cover frame for door cut-out for molded u — — — 3VA9034-0SB20
case circuit breaker — u — — 3VA9234-0SB20
n 4-pole, door cut-out with trip unit
— — u — 3VA9144-0SB20
— — — u 3VA9344-0SB20

7
Cover frame for door cut-out for MO320 u — — — 3VA9033-0SB10
motor operators — u u — 3VA9237-0SB30

CIRCUIT BREAKERS
MOLDED CASE
— — — u 3VA9377-0SB30
Cover frame for door cut-out for front u — — — 3VA9033-0SB10
mounted rotary operators — u u — 3VA9143-0SB10
— — — u 3VA9373-0SB10
Cover frame for door cut-out for front — — — u 3VA9377-0SB30
mounted rotary operator with door
interlock
Cover frame for door cut-out for door — u u — 3VA9233-0SB20
feedthrough — — — u 3VA9333-0SB20

Labeling plate for cover frame 3VA9087-0SX10

a 2 mounting plates are required. They are screwed onto b Breakers with plug-in unit can be mounted on the
the profile rail that can be ordered above. Different mounting plates, but the profile rails cannot be used.
breakers can be mutually interlocked.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-95


Revised on 05/31/19

3VA Molded Case Circuit Breakers


3VA Accessories and Spare Parts Selection

Other accessories
For molded case circuit break-
ers/rated current
3VA5
3VA6 3VA6
3VA5 3VA5 150A 400A
Type 125A 250A 250A 600A Part Number
Busbar adapter system with 60 mm u — — — 8US1211-4SS00
busbar center-to-center spacing — u u — 8US1213-4AP03
3-pole
— — — u 8US1213-4AH04

Busbar adapter system with 60 mm u — — — 8US1215-4SS00


busbar center to center spacing,
bottom fed, 3-pole

Metric mounting screw kit u — — — 3VA9151-0SS10


For fixed mounted breakers 1-pole
Metric mounting screw kit (2 pcs) u — — — 3VA9116-0SS10
For fixed mounted breakers 2-pole
Metric mounting screw kit (4 pcs) u u — — 3VA9114-0SS10
For fixed mounted breakers 3-,4-pole
Metric mounting screw kit — — u — 3VA9126-0SS10
For fixed mounted breakers 3-pole
Metric mounting screw kit — — u — 3VA9124-0SS10
For fixed mounted breakers 4-pole
Metric mounting screw kit — — — u 3VA9328-0SS10
7

For fixed mounted breakers 3-,4-pole


Metric mounting screw kit — — u — 3VA9124-0SS10
For plug-in and draw-out unit
MOLDED CASE
CIRCUIT BREAKERS

SAE mounting screw kit (2 pcs) u 3VA9151-0SS00


For fixed mounted breakers 1-pole
SAE Mounting screw kit (2 pcs) u 3VA9156-0SS00
For fixed mounted breakers 2-,3-pole
SAE Mounting screw kit (4 pcs) u 3VA9154-0SS00
For fixed mounting breakers 4-pole
SAE Mounting screw kit (4 pcs) u u 3VA9164-0SS00
For fixed mounted breakers 3-,4-pole and 3VA6 150/250
plug-in and draw-out units
SAE Mounting screw kit (2 pcs) u u 3VA9166-0SS00
For fixed mounted breakers 2-,3-pole
SAE Mounting screw kit (4 pcs) u 3VA9368-0SS00
For fixed mounted breakers 2-,3-,4-pole and 3VA6 400/600
plug-in and draw-out units

7-96 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 10/31/18

3VA Molded Case Circuit Breakers


3VA Accessory Electrical Requirements Technical data

Internal accessories
Auxiliary switches electrical requirements
Auxiliary switches and Auxiliary switches and alarm Auxiliary switches and
alarm switches HQ switches HQ_electronic alarm switches HP

AUX LCS TAS EAS AUX LCS TAS EAS AUX LCS TAS
Rated Ue V AC 240 24 600
operational 50 Hz
voltage V DC 250 24 250
Conventional Ith = Ie A 6 0.3 10
free-air thermal
current
IEC AC-12 12 V A 6 0.3 10
Ratings 24 V A 6 0.3 10
Listed 48 V A 6 -- 10
125 V A 6 -- 10
220/240 V A 6 -- 10
380/440 V A -- -- 6
600 V A -- -- 2
AC-15 12 V A 3 0.3 6
2/4 V A 3 0.3 6
48 V A 3 -- 6
125 V A 3 -- 6
220/240 V A 3 -- 6
380/440 V A -- -- 2
600 V A -- -- 0.6
DC-12 12 V A 6 0.1 6
24 V A 4 0.1 6
48 V A 2 -- 2
110 V A 0.5 -- 0.6

7
250 V A 0.25 -- 0.3
DC-13 12 V A 1 0.07 3
24 V A 0.8 0.07 3

CIRCUIT BREAKERS
MOLDED CASE
48 V A 0.4 -- 0.8
110 V A 0.2 -- 0.2
250 V A 0.1 -- 0.1
Max. rated Inductive load 24 V A 3 0.3 6
current (UL/CSA) (0.75-0.8 AC) 300 V A 3 -- 6
600 V A -- -- 6
Pilot duty (AC) 24 V A 3 -- 6
127 V A 3 -- 6
240 V A 3 -- 3
480 V A -- -- 1.5
600 V A -- -- 1.2
Resistive load (DC) 24 V A 0.25 0.1 0.3
250 V A 0.25 -- 0.3
Resistive load - pilot 125 V A 0.6 -- 0.9
duty sequence (DC) 250 V A 0.3 -- 0.55
Minimum load At 24 mA 70 0.5 70
V DC
At 5 V DC mA -- 1 --

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-97


Revised on 10/31/18

3VA Molded Case Circuit Breakers


3VA Accessory Electrical Requirements Technical data

Shunt trip/undervoltage electrical requirements


Shunt trip left Shunt trip Undervoltage Universal
STL flexible STF releases UVR release UNI

Power consumption Ue 12 V DC W 50 -- -- --
24 50 V AC/60 Hz VA 50 -- -- --
24 ... 30 V DC W 7 ... 50 -- -- --
48 ... 60 50 V AC/60 Hz VA 15 ... 20 -- -- --
48 ... 60 V DC W 20 ... 30 -- -- --
110 ... 127 50 V AC/60 Hz VA 30 ... 40 -- -- --
110 ... 127 V DC W 30 ... 40 -- -- --
208 ... 277 50 V AC/60 Hz VA 16 ... 35 -- -- --
220 ... 250 V DC W 28 ... 35 -- -- --
380 ... 600 50 V AC/60 Hz VA 10 ... 30 -- -- --
24 50 V AC/60 Hz VA -- 300 -- --
48 ... 60 50 V AC/60 Hz VA -- 340 ... 600 -- --
110 ... 127 50 V AC/60 Hz VA -- 500 ... 650 -- --
208 ... 277 50 V AC/60 Hz VA -- 360 ... 650 -- --
380 ... 500 50 V AC/60 Hz VA -- 330 ... 600 -- --
600 50 V AC/60 Hz VA -- 300 -- --
12 V DC W -- -- < 2.5 --
24 V DC W -- -- < 2.5 --
48 V DC W -- -- < 2.5 --
60 V DC W -- -- < 2.5 --
125 ... 127 V DC W -- -- < 2.5 --
220 ... 230 V DC W -- -- < 2.5 --
7

250 V DC W -- -- < 2.5 --


24 50 V AC/60 Hz VA -- -- <2 --
MOLDED CASE
CIRCUIT BREAKERS

48 50 V AC/60 Hz VA -- -- <2 --
60 50 V AC/60 Hz VA -- -- <2 --
110 50 V AC/60 Hz VA -- -- <2 --
120 ... 127 50 V AC/60 Hz VA -- -- <2 --
208 ... 230 50 V AC/60 Hz VA -- -- <2 --
380 ... 400 50 V AC/60 Hz VA -- -- < 2.5 --
440 ... 480 50 V AC/60 Hz VA -- -- < 2.5 --
12 V DC (Cat II; W -- -- -- UVR: < 2.5
PELV/SELV) SHT: 20
24 V DC (Cat II; W -- -- -- UVR: < 2.5
PELV/SELV) SHT: 20
48 V DC (Cat II; W -- -- -- UVR: < 2.5
PELV/SELV) SHT: 20

7-98 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/28/19

3VA Molded Case Circuit Breakers


3VA Accessory Electrical Requirements Technical data

Shunt trip/undervoltage electrical requirements


Shunt trip left Shunt trip Undervoltage Universal
STL flexible STF releases UVR release UNI

Rated impulse withstand Uimp kV 6 4 0.5


voltage 3VA UL Molded Case Circuit Breakers
Making current Imax at Accessories
V 1.5 A/24 V AC and
18 Spare
A/24 V AC Parts
5 mA/480 V 1.5 A/24 V
Maximum tripping time ms < 10
Service life Electrical trips Motor operators
8500
Mechanical switching cycles of the circuit breaker 25000
Priority over other control
signals
■ Overview
Given ■ Benefi
Degree of protection Lid of the accessories compartment closed MO320 front motor operator
IP40 • Rem
Lid of the accessories compartment open IP 20 mea
The MO320 motor operator is mounted on the front of the 3VA UL
Minimum signal duration ms 40
molded case circuit 40 --
breaker and opens 40
and closes the molded • Clea
Response voltage shunt Pick-up (circuit Us/V % 70 ... 110 -- 70 ... 110
case circuit breaker by means of digital input commands (e.g. quic
Benefits
trip breaker trips)
from pushbuttons or a PLC). It can also be operated manually, • Lock
Undervoltage release of thePick-up
• Remote operation molded(circuit
case circuitUs/V
breaker by % -- -- 85 ... 110
response however, and a handle is provided on the unit for this purpose. • Even
meansvoltage breaker can be
of digital input commands
he 3VA UL switched on) for is
he molded • Clear switching position indication including TRIP provides a The motor operator also features a clear MCCB position
Pick-up (circuit Us/V % -- -- 35 ... 70
nds (e.g. quick visual overview and prevents
breaker trips)operating errors indicator which indicates ON and OFF and, via LED, whether the
manually, • Locking capability
Tripping frequency prevents unauthorized
Trips per hour operations circuit breaker
Unlimited
has tripped
120
(TRIP). It is thus possible to identify
Unlimited ■ Design
purpose. • Even with for
a mounted the switching position of the molded case circuit breaker at any
Can be used electricalMO320 the 3VA still meets the standards No No Yes • The
for isolating
interlocking characteristics
of molded case defined by IEC / EN 60947-1 time.
on a mo
hether the circuit breakers
Two different reset modes can be selected, i.e. in one mode, the lid o
o identify Design operator resets the molded case circuit breaker automatically
ker at any and in the other, it waits for confirmation by an OFF signal before
• The MO320 motor operator is simply snapped into position on ■ Techn

7
a mounting frame that is installed instead of the accessories it resets the breaker.
mode, the lid of the molded case circuit breaker. MO320
Motor operator electrical requirements Furthermore, the motor operator can be locked in the

CIRCUIT BREAKERS
MOLDED CASE
matically
nal before Technical specifications
OFF position by means of several padlocks.

3VA5 Degree
MO320 motor operator 3VA5 3VA5 3VA6 3VA6 Rated c
125 A 250 A 150 A/ 400 A/ (operat
250 A 600 A supply
Degree of protection NEMA 1
Rated control supply voltage 24 V ... 60 V DC (0.85 ... 1.26)
Rating
(operating range of control 110 V ... 230 V AC/ Make ti
supply voltage) 110 V ... 250 V DC (0.85 ... 1.1) Break t
Rating 250 W, max. 500 W (60 ms)
Make time, typically < 800 ms < 1000 ms < 1700 ms
Break time, typically < 800 ms < 1000 ms < 1400 ms

4 ■ Selection and ordering data


Version For molded case circ
For molded case circuit DT Article No. Price PE PS*/ PG breakers/
breakers/ per PU (UNIT, P. unit rated current
rated current SET,
M) 3VA5 3VA5 3VA6
3VA5 3VA5 3VA6 3VA6
125 A 250 A 150 A
125 A 250 A 150 A, 400 A,
250 A 600 A
250 A
Siemens
Motor Industry, Inc. SPEEDFAX™ 2017 Product Catalog
operators 7-99
ergy feature Motor operators without stored energy feature 
(MO320)
Revised on 02/06/18

Sentron Molded Case Circuit Breakers


Catalog Numbering System Selection/Application

If used on 250A frame and above means


non-interchangeable trip breaker with
factory assembled frame and trip. Solid
state trip and current limiting (S or C in
first character) are non-interchangeable
only, and the “X” is omitted.

X D

Trip Unit Type


— Omitted – Thermal-Magnetic
S — Sensitrip® Electronic Trip
Sentron Series Type/Interrupting Range
— Omitted – Standard Rating
H — High IC Rating
HH — Extra High IC Rating
C — Highest IC Rating and Current Limiting
Frame Identifier
E — Type ED M — Type MD
F — Type FD N — Type ND
J — Type JD P — Type PD
L — Type LD R — Type RD
LM — Type LMD
Maximum Voltage
2 — 240 Vac
4 — 480 Vac
6 — 600 Vac
Number of Poles
1
2
3
A — used to indicate advanced electronic trip unit with maintenance mode capability (always 3 poles)
B — used to indicate basic electronic trip unit (always 3 poles)
(Specific Application Type)
B — Standard 40°C Breaker
M — Calibrated for 50°C Application
F — Frame Only
T — 40°C Trip Unit Only
W — 50°C Trip Unit Only
S — Molded Case Switch
L — Low Instantaneous Range ETI Breaker
7

A — Standard Range ETI Breaker


H — High Instantaneous Range ETI Breaker
MOLDED CASE
CIRCUIT BREAKERS

Maximum Continuous Current Rating


ED Frame — 015, 020, 025, 030, 035, 040, 045, 050, 060, 070, 080, 090, 100, 110, 125
FD Frame — 070, 080, 090, 100, 110, 125, 150, 175, 200, 225, 250
JD Frame — 200, 225, 250, 300, 350, 400
LD Frame — 250, 300, 350, 400, 450, 500, 600
LMD Frame — 500, 600, 700, 800
MD Frame — 500, 600, 700, 800
ND Frame — 900, 100 (1000A), 120 (1200A)
PD Frame — 120 (1200A), 140 (1400A), 160 (1600A)
RD Frame — 160 (1600A), 180 (1800A), 200 (2000A)
Suffix
L — where applicable indicates a breaker shipped with line/loads lugs installed
A — used with a switch to show automatic self protection
Y — 400 Hertz
H — 100% rated
P — Load side lugs only
NAV — Navel Ratings

NOTE:

— Position omitted if not used.

7-100 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 06/30/19

Molded Case Circuit Breakers


ED 125A Frame Sentron Series Selection

Ordering Instructions
All ED Frame Sentron circuit breakers are supplied with load side lugs. If line side lugs are required, add ”L” suffix to catalog number.
Consult Siemens sales office for any addditional charge
50°C Calibration, 400HZ - see page 7-146. All ED frame circuit breakers may be reverse connected

Type ED2e Blue Label Shipping Weights


1-Pole 2-Pole 3-Pole Number of Number per Shipping
Poles Carton Weight (lbs.)
Continuous 125V DC
120V AC 125V DC 240V AC 250V DC 240V AC ED2, ED4, ED6, HED4, HHED6
Current Rating
@ 40° C Catalog Number Catalog Number Catalog Number 1 30 38
015 ED21B015dn ED22B015 ED23B015 2 10 25
020 ED21B020dn ED22B020 ED23B020 3 10 38
25 ED21B025n ED22B025n ED23B025n CED6
030 ED21B030n ED22B030 ED23B030 2 5 20
35 ED21B035n ED22B035n ED23B035n 3 5 30
040 ED21B040n ED22B040 ED23B040
45 ED21B045n ED22B045n ED23B045n
050 ED21B050n ED22B050 ED23B050 Lugs
060 ED21B060n ED22B060 ED23B060 Ampere No. of Catalog Wire
070 ED21B070n ED22B070 ED23B070 Rating Poles Number Range
80 ED21B080n ED22B080n ED23B080 Aluminum Body Lugs
90 ED21B090n ED22B090n ED23B090n
100 ED21B100n ED22B100 ED23B100 Line/Load #14–#10 Cu
All 15–25A 1, 2, 3
SA1E025 #12–#10 Al
Line Side
Type ED4e Blue Label All 30–100A 1, 2, 3
LN1E100
#10–1/0 Cu/Al

1-Pole 2-Pole 3-Pole ED2, 4, 6, HED4 Load Side


1 #10–#4 Cu/Al
Continuous 120V AC 30-60A LD1E060
Current Rating 277V AC 125V DC 480V AC 250V DC 480V AC
ED2, 4, 6, HED4 Load Side
@ 40° C Catalog Number Catalog Number Catalog Number 1 #6–#1/0 Cu/Al
70-100A LD1E100
015 ED41B015d — ED43B015
020 ED41B020d ED42B020 ED43B020 ED2, 4, 6, HED4,
Load Side
HHED6 2, 3 #10–1/0 Cu/Al
025 ED41B025 ED42B025 ED43B025 LN1E100
30-100A
030 ED41B030 ED42B030 ED43B030
035 ED41B035n ED42B035n ED43B035 Line/Load #3–3/0 Cu
All 110, 125A 2, 3
040 ED41B040 ED42B040 ED43B040 TA1E6125 #1–2/0 Al
045 ED41B045n ED42B045n ED43B045 Copper Body Lugs
050 ED41B050 ED42B050 ED43B050 Line/Load #10–1/0 Cu
All 30–125A 1, 2, 3
060 ED41B060 ED42B060 ED43B060 TC1ED6150c only
070 ED41B070 ED42B070 ED43B070 Compression Lugs

7
080 ED41B080n ED42B080n ED43B080 All ED, HED, HHED, CED CCE125 2/0
090 ED41B090n ED42B090n ED43B090

CIRCUIT BREAKERS
MOLDED CASE
100 ED41B100 ED42B100 ED43B100
110 ED41B110 ED42B110n ED43B110
125 — ED42B125 ED43B125 Enclosures (Neutral Included)
Type Catalog Number
Type ED6e Blue Label
1 (Surface) E2N1S (15–100A)
1-Pole 2-Pole 3-Pole 3-Pole 1 (Flush) E2N1F (15–100A)
Continuous 3R E2N3R (15–100A)
Current 4–4X ED6SS4 (15–125A)
Rating 347V AC 600V AC 250V DC 600V AC 500V DC 600V DC
7–9 EA (15–60A)
@ 40° C Catalog Number Catalog Number Catalog Number Catalog Number 7–9 EB (70–100A)
15 ED61B015 — — ED63D015L 12 E2N12 (15–100A)
20 ED61B020 ED62B020 ED63B020 ED63D020L 1 (Surface) CED6N1S b
25 ED61B025 ED62B025n ED63B025 ED63D025L 1 (Flush) CED6N1F b
30 ED61B030 ED62B030 ED63B030 ED63D030L 3R CED6N3R b
12 CED6N12 b
35 ED61B035 — ED63B035 ED63D035L
40 ED61B040 — ED63B040 ED63D040L
45 ED61B045n — ED63B045 ED63D045L
50 ED61B050 — ED63B050 ED63D050L
60 ED61B060 — ED63B060 ED63D060L
70 ED61B070n — ED63B070 —
80 ED61B080 — ED63B080 —
90 ED61B090 — ED63B090 —
100 ED61B100n — ED63B100 —
110 — — ED63B110 —
125 — — ED63B125 —
Note: ED frame circuit breakers qualified to UL 489 b For
CED types and all 110–125 ampere ED frames.
Supplement SB “Naval”— See page 7-146 for c See Note: A, page 7-143. Modifications page 7-146
additional information d SWD rated. Enclosures Section 6
n Built to order. Allow 2–3 weeks for delivery. e HACR rated. Accessoriespages7-103and7-150to7-155
a CSA Certified only (Not UL)  Not for use with HHED6 breakers.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-101
Revised on 07/31/19

Molded Case Circuit Breakers


ED 125A Frame Sentron Series Selection/Dimensions

Type HED4 Black Label FIGURE1 - ED, HED, HHED


1-Pole 2-Pole 3-Pole


Continuous D


Current Rating 277V AC 125V DC 480V AC 250V DC 480V AC


@ 40° C Catalog Number Catalog Number Catalog Number
015 HED41B015a HED42B015 HED43B015


D1


020 HED41B020a HED42B020 HED43B020
25 HED41B025 HED42B025n HED43B025 H
030 HED41B030 HED42B030 HED43B030
35 HED41B035n HED42B035n HED43B035
040 HED41B040 HED42B040 HED43B040 � �


45 HED41B045n HED42B045n HED43B045 � � � �
W3
050 HED41B050n HED42B050 HED43B050 W1 W2
060 HED41B060n HED42B060n HED43B060
070 HED41B070n HED42B070n HED43B070 1-POLE 2-POLE 3-POLE
80 HED41B080n HED42B080n HED43B080
90 HED41B090n HED42B090n HED43B090 FIGURE 2 - CED (3-Pole shown)
100 HED41B100n HED42B100n HED43B100
110 — HED42B110n HED43B110


D


125 — HED42B125n HED43B125


D1


Fuseless Current Limiting
H
Type HHED6 Black Label Type CED6 Red Label
3-Pole 2-Pole 3-Pole
Continuous
Current 600V AC, 600V AC,
Rating 600V AC 250V DC 500V DC b
@ 40°C Catalog Number  Catalog Number Catalog Number


015 HHED63B015A CED62B015 CED63B015 � �

020 HHED63B020 CED62B020n CED63B020 W2, W3


025 HHED63B025 — —
030 HHED63B030 CED62B030n CED63B030 Dimensions (in inches)
035 HHED63B035 — —
Breaker Type W1 W2 W3 H D D1
040 HHED63B040 — CED63B040
Figure 1
045 HHED63B045 — —
ED2, ED4,
050 HHED63B050 — CED63B050 1 2 3 6.35 3.92 4.56
ED6, HED4,
060 — CED62B060n CED63B060 ED6 ETIc
070 — CED62B070n CED63B070 Figure 1
— 2 3 6.53 3.92 4.56
080 — CED62B080n CED63B080 HHED6
7

090 — CED62B090n CED63B090 Figure 2


CED6, — 2 3 9.58 3.92 4.56
100 — CED62B100n CED63B100
CED6 ETIc
MOLDED CASE
CIRCUIT BREAKERS

110 — — CED63B110n
125 — CED62B125n CED63B125

Interrupting Ratings
UL 489 AIR (File #E10848) IEC 947-2
RMS Symmetrical Amperes (KA) Volts AC (50/60Hz)
Volts AC Volts DC 220/240 380/415 500
Breaker Type 120 240 277 347 480 600 125 250 500 600 lcu lcs lcu lcs lcu lcs
ED2 (1-P) 10 — — — — — 5 — — — — — — — — —
ED2 (2, 3-P) — 10 — — — — — 5 (2-P) — — — — — — — —
ED4 (1-P) 65 — 22 — — — 30 — — — — — — — — —
ED4 (2, 3-P) — 65 — — 18 — — 30 (2-P) — — — — — — — —
ED6 (1P) — — — 30 — — — 30 — — — — — — — —
ED6 (2, 3-P) — 65 — — 25 18 — — 18 (3-P) — 65 17 35 9 18 5
ED6 (3-P) — — — — — — — — — 10g — — — — — —
HED4 (1-P)
100 — 65 — — — 30 — — — — — — — — —
(15–30A)
HED4 (1-P)
100 — 25 — — — 30 — — — — — — — — —
(35–100A)
HED4 (2, 3-P) — 100 — — 42 — — 30 (2-P) — — — — — — — —
HHED6 (2, 3-P) — 100 — — 65 18 — — — — — — — — — —
CED6 (2, 3-P) — 200 — — 200 100 — 50 (2-P) 30 (3-P) — — — — — — —
n Built to order. Allow 2–3 weeks for delivery. c ED6-ETI,CED6-ETI, see page 7-130 for ordering eHACR
 rated.
a SWD rated. information. f HHED63B015A is rated 18KAIC at 600/347V.
dSingle
 Pole 15-30A 30KA @ 347V non-UL. g 600VDC

only applies to ED63D___ breakers
bWhen wired as shown on page 7-4, this circuit breaker is
35-100A 18KA @ 347V non-UL.
UL listed and rated for use on 500V DC ungrounded UPS
systems.

7-102 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 12/31/19

Molded Case Circuit Breakers


Accessories Selection

Accessories for: Shunt Trip Combinations


1 Shunt Trip
ED 125A Frame Control 1 Shunt Trip and 1 Auxiliary Switch 1 Shunt Trip and 1 Shunt Trip and 2
Voltage 1 Shunt Trip 1 Auxiliary Switch and 1 Alarm Switch 1 Alarm Switch Auxiliary Switches
AC DC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
024 S17ED60 — — — —
048 S18ED60 — — — —
120 S01ED60 S01ED62A S01ED62AB S01ED62B S01ED62AA
208 — S02ED62As S02ED62ABs S02ED62Bs S02ED62AAs
240 S03ED60 S03ED62A S03ED62AB S03ED62Bs S03ED62AAs
277 S15ED60s S15ED64As S15ED64ABs S15ED64Bs —
480 S04ED60 S04ED64As S04ED64ABs S04ED64Bs —
012 S16ED60s S16ED62As — — —
024 S07ED60 S07ED62A S07ED62ABs S07ED62Bs S07ED62AAs
048 S09ED60s S09ED62As S09ED62ABs S09ED62Bs S09ED62AAs
125 S11ED60s S11ED62As S11ED62ABs S11ED62Bs S11ED62AAs
250 S13ED60s S13ED62As S13ED62ABs S13ED62Bs S13ED62AAs
Combinations
Available only when ordered together.
Only one module can be added to a Undervoltage Trip Combinations
breaker. Additional accessories, which 1 Undervoltage Trip
always attach to the left pole, cannot be 1 Undervoltage and 1 Auxiliary 1 Undervoltage 1 Undervoltage
added to the combination later. Adds 1 Control 1 Undervoltage Trip and Switch and Trip and Trip and 2
Voltage Trip 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch Auxiliary Switches
inch pole space.
AC DC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number

Equipment 120
208
U01ED60
U02ED60s
U01ED62A
U02ED62As
U01ED62ABs
U02ED62ABs
U01ED62Bs
U02ED62Bs
U01ED62AAs
U02ED62AAs
Ground Sensing 240 U03ED60 U03ED62As U03ED62ABs U03ED62Bs U03ED62AAs
A field addable kit containing 30mA or 277 U16ED60s U16ED64As U16ED64ABs U16ED64Bs —
480 U06ED60s U06ED64As U06ED64ABs U06ED64Bs —
5 mA ground fault accessory module, 600 U08ED60s — — — —
current transformer with 24 inch leads, 024 U13ED60 U13ED62As U13ED62ABs U13ED62Bs U13ED62AAs
and current transformer mounting 048 U14ED60s U14ED62As U14ED62ABs U14ED62Bs U14ED62AAs
equipment. Current transformer to 125 U10ED60s U10ED62As U10ED62ABs U10ED62Bs U10ED62AAs
mount in gutter of lighting panel or 250 U12ED60s U12ED62As — — U12ED62AAs
any control panel. Accessory module
operates from separate 120V control
power source. Auxiliary Switch Combinations
Maximum 1 Alarm Switch and 1 Alarm Switch and
Both 30MA and 5MA devices are Voltage 1 Auxiliary Switch 1 Auxiliary Switch 2 Auxiliary Switches 2 Auxiliary Switches
equipment protection devices only.
AC DC Catalog Number Catalog Number Catalog Number Catalog Number

7
Do not use for personnel protection.
240 250 A01ED62 A01ED62B A02ED62 A02ED62B
480 A01ED64 A01ED64B — —

CIRCUIT BREAKERS
MOLDED CASE
Maximum
Voltage 1 Auxiliary Switch
AC DC Catalog Number
24 A01EDLV Gold Plated Contacts—for PLC use

Alarm Switch Only


Maximum
Voltage 1 Alarm Switch
AC DC Catalog Number
240 250 B00ED62
480 B00ED64
GF01ED60

Ground Fault Sensing Relay Kit — Equipment Protection Only


For Use With Number of Catalog Number
Breaker Frame Poles Description 30mA 5mA
Basic Kit GF01ED60 GF01ED65
CED6, ED2, ED4 Basic Kit with Normally
GF01ED60B0 GF01ED65B0s
ED6, EFC, EFF, 1, 2, 3 Open Bell Alarm

HED4, HHED6
Basic Kit with Normally
Closed Bell Alarm GF01ED60BC GF01ED65BCs

s Built to order. Allow 6–8 weeks for delivery.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-103
Revised on 05/31/18

Molded Case Circuit Breakers


FD 250A Frame Sentron Series Selection

Type FXD6-A a Blue Label Ordering Information


Non-Interchangeable Trip (Assembled Circuit Breaker – Without Lugs) Complete Breaker Unassembled
Continuous
2-Pole 3-Pole
with Lugs
Current Rating Prices of FD6, HFD6, and HHFD6
@ 40°C Catalog Number Catalog Number
70 FXD62B070n FXD63B070
breakers includes frame, trip and
80 FXD62B080n FXD63B080 both line and load lugs (TA1FD350A).
90 FXD62B090n FXD63B090 When ordered by these catalog
100 FXD62B100 FXD63B100 numbers, the customer will receive
110 FXD62B110n FXD63B110
125 FXD62B125 FXD63B125
the frame, trip, and lugs separately
150 FXD62B150 FXD63B150 packaged. For applications requiring
175 FXD62B175 FXD63B175 different lugs, order individual items
200 FXD62B200 FXD63B200 as needed.
225 FXD62B225 FXD63B225
250 FXD62B250 FXD63B250 Complete Breaker Assembled with-
out Lugs
Type FD6-A Blue Label Prices of FXD6, HFXD6, HHFXD6,
and CFD6 includes frame with
Interchangeable Trip
non-interchangeable trip unit
Complete Breaker
Continuous
Unassembled w/Lugs Frame Only Trip Unit Only
installed only. Order required lugs
Current Rating separately. For line and load lugs
@ 40°C Catalog Number Catalog Number Catalog Number
(TA1FD350A) installed, add suffix
2-Pole 600V AC, 250V DC b “L” to catalog number (add 2 times
70 FD62B070n FD62T070n list price of lugs for each pole).
80 FD62B080n FD62T080n
90 FD62B090n FD62T090n 50°C Applications see page 7-146.
100 FD62B100n FD62T100n 400 Hz Applications see page 7-146.
110 FD62B110n FD62T110n
125 FD62B125n FD62F250 FD62T125n
150 FD62B150 FD62T150
175 FD62B175n FD62T175n Lugs For 75°C Wire e
200 FD62B200 FD62T200
Catalog Wire
225 FD62B225n FD62T225n
Number Range
250 FD62B250n FD62T250n
#6—350 kcmil Cu
3-Pole 600V AC, 500V DC c TA1FD350A
#4—350 kcmil Al
70 FD63B070n FD63T070n TC1FD350 #6—350 kcmil Cu
80 FD63B080n FD63T080n
90 FD63B090n FD63T090n Compression Lug
100 FD63B100 FD63T100 CCF250 350 kcmil Cu/Al
110 FD63B110n FD63T110n
125 FD63B125 FD63F250 FD63T125
7

150 FD63B150 FD63T150


175 FD63B175 FD63T175 Enclosures
200 FD63B200 FD63T200 Catalog
MOLDED CASE
CIRCUIT BREAKERS

225 FD63B225 FD63T225 Type Number


250 FD63B250 FD63T250 1 F6N1S(F)
3R F6N3R
Interrupting Ratings 4-4X FD6SS4
RMS Symmetrical Amperes (KA) 7-9 EC2
12 F6N12
UL 489 AIR (File E10848) IEC 947-2g Neutral d N250
Volts AC (50/60Hz) Volts DC Volts AC (50/60Hz)
Breaker 240 480 600 250 500 c 220/240 380/415 500
Type lcu lcs lcu lcs lcu lcs
FXD6-A, FD6-A 65 35 22 30 (2-P) 18 (3-P) 65 33 35 18 — —
HFXD6 , HFD6 100 65 25 30 (2-P) 25 (3-P) 100 50 65 33 — —
HHFD6 , HHFXD6 200 100 25 — — — — — — — —
CFD6 200 200 100 30 (2-P) 50 (3-P) — — — — — — Modifications page 7-146
Enclosures Section 6
Instantaneous Adjustment Trip Range Accessories pages 7-106 and 7-150 to 7-155

Nominal Instantaneous Values n Built to order. Allow 2–3 weeks for delivery.
a Type FXD6-A circuit breakers are UL Listed for reverse
+20% +20%
Breaker Ampere Tolerance Tolerance fed applications.
b 2-pole units are 3-pole width.
Rating Low 2 3 4 5 6 7 High c When
 wired as shown on page 7-4, this circuit breaker is
170-90 600 640 690 730 770 810 850 900 UL listed and rated for use on 500V DC ungrounded UPS
systems only.
100-110 700 770 840 920 990 1060 1140 1200 d Order neutral as separate item.
125-150 800 900 1000 1100 1200 1300 1400 1500 e See Note: A, page 7-143.
175-200 900 1060 1210 1370 1520 1780 1930 2000 f HACR rated.
225-250 1100 1300 1500 1700 1900 2100 2300 2500 g Only applicable to interchangable trip unit types:
FXD6A, HFXD6A.
Note: FD frame qualified to UL489 supplement SB “NAVAL”.
See page 7-146 for additional information.

7-104 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Molded Case Circuit Breakers
FD 250A Frame Sentron Series Selection/Dimensions

Type HFD6, Type HFXD6 bc Black Label


Interchangeable Trip
Continuous Complete Breaker
Current Rating Unassembled w/Lugs Frame Only Trip Unit Only
@ 40°C Catalog Number Catalog Number Catalog Number
2-Pole 600V AC, 250V DC (3-Pole Width)
70 HFD62B070n FD62T070n L
80 HFD62B080n FD62T080n
90 HFD62B090n FD62T090n
100 HFD62B100n FD62T100n
110 HFD62B110n FD62T110n
125 HFD62B125n HFD62F250 FD62T125n
150 HFD62B150n FD62T150n


175 HFD62B175n FD62T175n
200 HFD62B200n FD62T200n � W �

D
225 HFD62B225n FD62T225n
250 HFD62B250n FD62T250n Figure 1 Figure 2
3-Pole 600V AC, 500V DC 
70 HFD63B070n FD63T070n Dimensions (in inches)
80 HFD63B080n FD63T080n Breaker D1
90 HFD63B090n FD63T090n Type W L D (to
100 HFD63B100 FD63T100 handle)
110 HFD63B110n FD63T110n
Figure 1
125 HFD63B125 HFD63F250 FD63T125
FXD6-A, FD6-A,
150 HFD63B150 FD63T150 HFD6, HFXD6, 4.50 09.50 4 5.25
175 HFD63B175 FD63T175 HHFD6, FD6-ETI 
200 HFD63B200 FD63T200
Figure 2
225 HFD63B225 FD63T225
CFD6,
250 HFD63B250 FD63T250 4.50 14.25 4 5.25
CFD6-ETI 
Type HHFD, HHFXD6 bc
3-Pole 600V AC, Extra High Interrupting Shipping Weights
70 HHFD63B070n FD63T070n Number of Number per Shipping
80 HHFD63B080n FD63T080n Poles Carton Weight (lbs.)
90 HHFD63B090n FD63T090n FD6-A, HFD6, HHFD6, FXD6-A
100 HHFD63B100 FD63T100 Assembled Circuit Breaker (less connectors)
110 HHFD63B110n FD63T110n 2 1 08.6
125 HHFD63B125 HHFD63F250 FD63T125 3 1 10
150 HHFD63B150 FD63T150 FD6-A, HFD6, HHFD6 Frame Only
175 HHFD63B175 FD63T175

7
2 1 07.5
200 HHFD63B200 FD63T200 3 1 08.7
225 HHFD63B225 FD63T225
FD6 Trip Unit Only

CIRCUIT BREAKERS
MOLDED CASE
250 HHFD63B250 FD63T250
2 1 01.1
3 1 01.3
Type CFD6-Ac CFD6 Assembled Circuit Breaker (less terminals)
Fuseless Current Limiting Red Label 3 1 16

Non-Interchangeable Trip (Assembled Circuit Breaker


without Lugs)
Continuous 3-Pole
Current Rating 600V AC/500V DC
@ 40°C Catalog Number
070 CFD63B070n
080 CFD63B080n
090 CFD63B090n
100 CFD63B100n
110 CFD63B110n
125 CFD63B125n
150 CFD63B150
175 CFD63B175
200 CFD63B200
225 CFD63B225
250 CFD63B250

n Built to order. Allow 2–3 weeks for delivery. breaker, change prefix identifier from HFD6 to HFXD6. d FXD6, ETI, CFD6, ETI — See page 7-130 for
a When Price equals frame and trip prices combined, e.g. price ordering information.
wired as shown on page 7-4, this circuit breaker
of HFXD63B250 equals price of HFD63F250 plus price of HACR rated.
 
is UL listed and rated for use on 500V DC ungrounded
FD63T250. Order lugs separately.
UPS systems. c Type HFXD6, HHFXD6, CFD6 are UL Listed for reverse
b For non-interchangeable trip 3-pole HFD6 type circuit
feed applications.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-105
Revised on 12/31/19

Molded Case Circuit Breakers


Internal Accessories Selection

Shunt Trip Combinations


Accessories: Control Voltage 1 Shunt Trip
for FD, FFC & FFF 250A Frames AC DC Catalog Number
024 S17FD60
120 S01FD60
240 S03FD60
277 S15FD60s
480 S04FD60
600 S06FD60s
012 S16FD60s
024 S07FD60
048 S09FD60s
125 S11FD60
250 S13FD60s

Undervoltage Trip Combinations


1 Undervoltage Trip and
Control Voltage 1 Undervoltage Trip 1 Auxiliary Switch

AC DC Catalog Number Catalog Number


S01FD60 120 U01FD60 W01FD64
208 U02FD60s W02FD64s
240 U03FD60 W03FD64s
277 U16FD60s W16FD64s
480 U06FD60s W06FD64s
600 U08FD60s —
024 U13FD60 W13FD64
048 U14FD60s W14FD64s
125 U10FD60s W10FD64s
250 U12FD60s W12FD64s

Auxiliary Switch Combinations


Voltage 1 Auxiliary Switch 2 Auxiliary Switches
AC DC Catalog Number Catalog Number
240 A01FD62 A02FD62
480 A01FD64 A02FD64
7

24 A01FDLV Gold Plated Contacts -


for PLC use
MOLDED CASE
CIRCUIT BREAKERS

Alarm Switch Combinations


Maximum 1 Alarm Switch and
Voltage 1 Alarm Switch 1 Auxiliary Switch
AC DC Catalog Number Catalog Number
480 250 B00FD64 C01FD64

s Built to order. Allow 6–8 weeks for delivery.


a Auxiliary switch application is for 480V AC maximum.
Note: Old F-frame accessories cannot be used in new
Sentron line. Likewise, new FD-frame accessories
cannot be used on old F-frame circuit breakers.

7-106 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 05/31/18

Molded Case Circuit Breakers


JD 400A Frame Sentron Series Selection

Type JXD2-A Ordering Information


240V AC, 2-Pole 250V DC Only Blue Label Complete Breaker Unassembled
Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) with Lugs
Continuous Current 2-Pole (3-Pole Width) 3-Pole
Prices of JD6, HJD6, and HHJD6
Rating @ 40°C Catalog Number Catalog Number breakers include frame, trip and
200 JXD22B200n JXD23B200 both line and load lugs (TA2J6500).
225 JXD22B225n JXD23B225 When ordered by these catalog
250 JXD22B250n JXD23B250 numbers, the customer will receive
300 JXD22B300 JXD23B300 the frame, trip, and lugs separately
350 JXD22B350n JXD23B350
packaged. For applications
400 JXD22B400 JXD23B400
requiring different lugs, order
Type JXD6-A a individual items as needed.
600V AC, 2-Pole 250V DC, 3-Pole 500V DC b Blue Label Complete Breaker Assembled with-
out Lugs
Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs)
200 JXD62B200n JXD63B200
Prices of JXD6, HJXD6, HHJXD6,
225 JXD62B225n JXD63B225 and CJD6 include frame with
250 JXD62B250n JXD63B250 non-interchangeable trip unit
300 JXD62B300 JXD63B300 installed only. Order required lugs
350 JXD62B350n JXD63B350 separately. For line and load lugs
400 JXD62B400 JXD63B400 (TA2J6500) installed, add suffix “L”
to catalog number (add 2 times list
Type JD6-A Blue Label price of lugs for each pole).
Interchangeable Trip 100% Rated (3-pole only)
Continuous Complete Breaker Types JXD6 and HJXD6 breakers
Current Rating Unassembled w/Lugs Frame Only Trip Unit Only are available with 100% ratings.
@ 40°C Catalog Number Catalog Number Catalog Number To order add suffix “H” to catalog
2-Pole 600V AC, 250V DC (3-Pole Width) number, and 10% to list price.n
200 JD62B200n JD62T200n 100% rated JD breakers require the
225 JD62B225n JD62T225n use of 90°C Cu cable sized at 75°C
250 JD62B250n JD62F400 JD62T250n
300 JD62B300n JD62T300n ampacity and lugs TC1J6600
350 JD62B350n JD62T350n or TC2J6500.
400 JD62B400 JD62T400 50°C Applications see page 7-146.
3-Pole 600V AC, 500V DC b
400Hz Applications see page 7-146.
200 JD63B200 JD63T200
225 JD63B225 JD63T225
250 JD63B250 JD63F400 JD63T250

7
300 JD63B300 JD63T300
350 JD63B350 JD63T350 Lugs For 75°C Wire c
400 JD63B400 JD63T400

CIRCUIT BREAKERS
MOLDED CASE
Cables
Interrupting Ratings Catalog
Number
per
Lug
Wire
Range
RMS Symmetrical Amperes (KA) TA2J6500 1, 2 #3/0-500 kcmil Cu
UL 489 AIR (File E10848) IEC 947-2e 2 #4/0-500 kcmil Al
TA1L6750 1 500-750 kcmil Al
Volts AC Volts DC Volts AC (50/60Hz) 1 500-600 kcmil Cu
(50/60Hz) 220/240 380/415 500 TC1J6600 1 #3/0-600 kcmil Cu
Breaker
TC2J6500 1, 2 #3/0-500 kcmil Cu
Type 240 480 600 250 500 b lcu lcs lcu lcs lcu lcs
Compression Lug
JXD2-A 065 — — 30 (2-P) — — — — — — —
CCL600 1 500 kcmil Cu/Al
JXD6-A, JD6-A 065 035 025 30 (2-P) 25 (3-P) 065 033 040 20 — —
HJD6-A, HJXD6-A 100 065 035 30 (2-P) 35 (3-P) 100 050 065 33 — —
HHJD6, HHJXD6 200 100 050 — — — — — — — —
CJD6-A 200 150 100 30 (2-P) 50 (3-P) — — — — — —

Instantaneous Adjustment Trip Range


Nominal Instantaneous Values
+20% +20%
Breaker Ampere Tolerance Tolerance
Rating Low 2 3 4 5 6 7 High
200-300 1250 1430 1610 1790 1960 2140 2320 2500
350-400 2000 2290 2570 2860 3140 3430 3710 4000
n Built to order. Allow 2–3 weeks for delivery. c SeeNote: A, page 7-143.
a Type JXD2 and JXD6 circuit breakers are UL Listed for
d  HACRrated. Modifications page 7-146
reverse feed applications.
eOnly applicable to interchangable trip unit types: Enclosures Section 6
b When wired as shown on page 7-4, this circuit breaker is JXD6-A, HJXD6-A. Accessories pages 7-110 and 7-150 to 7-155
UL listed and rated for use on 500V DC ungrounded UPS Note: JD frame qualified to UL489 supplement B
systems only. “NAVAL.” See page 7-146 for additional information.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-107
Molded Case Circuit Breakers
JD 400A Frame Sentron Series Selection/Dimensions

Type HJD6-A, HJXD6-A bdf Black Label


Interchangeable Trip
Complete Breaker
Continuous D1
Unassembled w/Lugs Frame Only Trip Unit Only �

Current Rating
@ 40°C Catalog Number Catalog Number Catalog Number
2-Pole 600V AC, 250V DC (3-Pole Width)
200 HJD62B200n JD62T200n
225 HJD62B225n JD62T225n
250 HJD62B250n HJD62F400n JD62T250n
300 HJD62B300n JD62T300n
350 HJD62B350n JD62T350n
400 HJD62B400n JD62T400
abe
3-Pole 600V AC, 500V DC D
� W �

D
200 HJD63B200 JD63T200
225 HJD63B225 JD63T225 Figure 1 Figure 2
250 HJD63B250 HJD63F400 JD63T250
300
350
HJD63B300
HJD63B350
JD63T300
JD63T350
Dimensions (in inches)
400 HJD63B400 JD63T400 To
Breaker Handle
Type W L D D1
Figure 1
Type HHJD6, HHJXD6 bdf Black Label JXD2-A, JXD6-A, JD6-A
HJD6-A, HJXD6-A, HHJD6, 7.5 11 4 5.44
2-Pole 600V AC (3-Pole Width) HJD6, HJXD6, HHJXD6,
200 HHJD62B200n JD62T200n JXD6-ETI,c SJD6, SHJD6
225 HHJD62B225n JD62T225n Figure 2
7.5 17.86 4 5.44
250 HHJD62B250n HHJD62F400n JD62T250n CJD6, CJD6-ETI,c SCJD6
300 HHJD62B300n JD62T300n
350 HHJD62B350n JD62T350n Enclosures (Except SCJD6)
400 HHJD62B400n JD62T400
3-Pole 600VAC Type Catalog Number
200 HHJD63B200 JD63T200 1 J6N1
225 HHJD63B225 JD63T225 3R J6N3R
250 HHJD63B250 HHJD63F400 JD63T250 12 J6N12
300 HHJD63B300 JD63T300 4X LD6SS4
7, 9 (200-250A) EC4
350 HHJD63B350 JD63T350
7, 9 (300-400A) EE
400 HHJD63B400 JD63T400
W60992
7

Neutral

Type CJD6-A ef Shipping Weights


MOLDED CASE
CIRCUIT BREAKERS

Fuseless Current Limiting Number of Number per Shipping


Red Label Poles Carton Weight (lbs.)
JXD2, JXD6, JD6, HJD6, HHJD6
Non-Interchangeable Trip (Assembled Circuit Breaker Assembled Breaker (less terminals)
Without Lugs) 2 1 17.5
Continuous 2-Pole 3-Pole 3 1 19.5
Current Rating 600V AC/250V DC 600V AC/500V DC JD6, HJD6, HHJD6 Frame Only
@ 40°C Catalog Number Catalog Number 2 1 14
200 CJD63B200n 3 1 15.5
225 CJD63B225n JD6 Trip Unit Only
250 For 2-pole application CJD63B250n 2 1 03.5
use outside poles of 3 1 04
300 3-pole circuit breaker CJD63B300n
CJD6 Complete Assembled Breaker
350 CJD63B350n
(less terminals)
400 CJD63B400
3 1 31.5

For inches / millimeters conversion, see Application Data section.


n Built to order. Allow 2–3 weeks for delivery.
 b For non-interchangeable 3-pole HJD6 or HHJD6 type c JXD6-ETI, CJD6-ETI see page 7-130 for ordering information.
circuit breaker change the prefix identifier to HJXD6 d Type HJXD6, HHJXD6 Circuit Breakers are UL listed for
2-pole units available in 3-pole construction.
or HHJXD6. Price equals price of frame plus price of reverse fed applications.
a When

wired as shown on page 7-4, this circuit breaker is trip, e.g. price of HJXD63B400 equals price of e CE applies to non-interchangeable type HJXD6-A only.
UL listed and rated for use on 500V DC ungrounded HJD63F400 plus price of JD63T400. Order lugs f HACR rated.
UPS systems only. separately.

7-108 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 10/31/18

Molded Case Circuit Breakers


SJD 400A Frame Digital Solid State Sentron Sensitrip IV Series Selection

Current Limiting
Type SJD6-B Type SHJD6-B Type SCJD6-B
Blue Label Black Label Red Label
Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC
Current Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
Rating (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit)
200 SJD6A200LI SJD6B200LI SHJD6A200LI SHJD6B200LI SCJD6A200LI SCJD6B200LI
300 SJD6A300LI SJD6B300LI SHJD6A300LI SHJD6B300LI SCJD6A300LI SCJD6B300LI
400 SJD6A400LI SJD6B400LI SHJD6A400LI SHJD6B400LI SCJD6A400LI SCJD6B400LI
200 SJD6A200LIG SJD6B200LIG SHJD6A200LIG SHJD6B200LIG SCJD6A200LIG SCJD6B200LIG
300 SJD6A300LIG SJD6B300LIG SHJD6A300LIG SHJD6B300LIG SCJD6A300LIG SCJD6B300LIG
400 SJD6A400LIG SJD6B400LIG SHJD6A400LIG SHJD6B400LIG SCJD6A400LIG SCJD6B400LIG
200 SJD6A200LSI SJD6B200LSI SHJD6A200LSI SHJD6B200LSI SCJD6A200LSI SCJD6B200LSI
300 SJD6A300LSI SJD6B300LSI SHJD6A300LSI SHJD6B300LSI SCJD6A300LSI SCJD6B300LSI
400 SJD6A400LSI SJD6B400LSI SHJD6A400LSI SHJD6B400LSI SCJD6A400LSI SCJD6B400LSI
200 SJD6A200LSIG SJD6B200LSIG SHJD6A200LSIG SHJD6B200LSIG SCJD6A200LSIG SCJD6B200LSIG
300 SJD6A300LSIG SJD6B300LSIG SHJD6A300LSIG SHJD6B300LSIG SCJD6A300LSIG SCJD6B300LSIG
400 SJD6A400LSIG SJD6B400LSIG SHJD6A400LSIG SHJD6B400LSIG SCJD6A400LSIG SCJD6B400LSIG

SJD 400A Frame – 100% Ratedb


Type SJD6-B Type SHJD6-B Ordering Information
Blue Label Black Label
Pricing information for all Digital
Max 3-Pole, 600V AC 3-Pole, 600V AC Sentron Series SJD Frames is
Current Catalog Number Catalog Number Catalog Number Catalog Number for complete breaker only - price
Rating (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit) required lugs as separate items -
200 SJD6A200LIH SJD6B200LIH SHJD6A200LIH SHJD6B200LIH lugs are suitable for 75°C Wire.
300 SJD6A300LIH SJD6B300LIH SHJD6A300LIH SHJD6B300LIH
400 SJD6A400LIH SJD6B400LIH SHJD6A400LIH SHJD6B400LIH SJD6-B, SHJD6-B and SCJD6-B are
200 SJD6A200LIGH SJD6B200LIGH SHJD6A200LIGH SHJD6B200LIGH acceptable for reverse connection
300 SJD6A300LIGH SJD6B300LIGH SHJD6A300LIGH SHJD6B300LIGH application.
400 SJD6A400LIGH SJD6B400LIGH SHJD6A400LIGH SHJD6B400LIGH
200 SJD6A200LSIH SJD6B200LSIH SHJD6A200LSIH SHJD6B200LSIH
300 SJD6A300LSIH SJD6B300LSIH SHJD6A300LSIH SHJD6B300LSIH
400 SJD6A400LSIH SJD6B400LSIH SHJD6A400LSIH SHJD6B400LSIH Shipping Weights
200 SJD6A200LSIGH SJD6B200LSIGH SHJD6A200LSIGH SHJD6B200LSIGH Breaker Number per Shipping

7
300 SJD6A300LSIGH SJD6B300LSIGH SHJD6A300LSIGH SHJD6B300LSIGH Type Carton Weight (lbs)
400 SJD6A400LSIGH SJD6B400LSIGH SHJD6A400LSIGH SHJD6B400LSIGH SJD6-B 1 20

CIRCUIT BREAKERS
MOLDED CASE
SHJD6-B 1 20
Trip Unit Adjustable Functions SCJD6-B 1 33
Short Short
Suffix Cont Long Instan- Short Time Time Ground Ground
Letter Trip Current Time taneous Time Fixed
2
lt Fault Fault Lugs for 75° C Wire a
Code Type Setting Delay Pick Up Pick Up Delay Delay Pick Up Delay
No. of
LI LI u u u
cables
LIG LIG u u u u u Catalog per con- Wire
LSI LSI u u u u u u Number nector Range
LSIG LSIG u u u u u u u u 2 #3/0-500 kcmil Cu
TA2J6500
2 #4/0-500 kcmil Al

Interrupting Ratings Neutral Transformers TA1L6750


1 500-750 kcmil Al
1 500-600 kcmil Cu
RMS Symmetrical kA
UL 489 (File E10848) Ampere Rating Catalog Number TC1J6600 1 #3/0-600 kcmil Cu
Breaker
Type 240V AC 480V AC 600V AC 200 N02SJD TC2J6500 2 #3/0-500 kcmil Cu
300 N03SJD TA2J630 2 #4-#3/0 Cu/Al
SJD6-B 65 35 25
400 N04SJD Compression Lug
SHJD6-B 100 65 35
SCJD6-B 200 150 100 CCL600 1 (pc.) #1/0-500 kcmil Cu/Al

Note: “G” suffix in catalog number denotes circuit All breakers built to order. Allow 2–3 weeks for delivery.
breaker for 3-phase, 3-wire systems. a Foradditional information, see Note: A, page 7-143.
For 3-phase, 4-wire, order correct 4th wire (neutral) Refer to the NEC for proper application of 100%
transformer as separate and additional item.
b
Enclosures Section 6
rated devices.
c Advanced trip unit equipped with DAS /
Accessories pages 7-110 and 7-150 to 7-155
Maintenance Mode. Requires customer-supplied 24V
external power supply, maintenance switch and light.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-109
Revised on 12/31/19

Molded Case Circuit Breakers


Internal Accessories Selection

Accessories for: Shunt Trip Combinations


JD 400A Frame 1 Shunt Trip and
Control Voltage 1 Shunt Trip 1 Auxiliary Switch
LD 600A Frame
AC DC Catalog Number Catalog Number
LMD 800A Frame
SJD 400A Frame 024 S17JLD6 —
048 S18JLD6s —
SLD 600A Frame
120 S01JLD6 S01JLD62A
240 S03JLD6 S03JLD62A
277 S15JLD6s S15JLD64As
480 S04JLD6 —
012 S16JLD6s S16JLD62As
024 S07JLD6 S07JLD62A
048 S09JLD6s S09JLD62A
125 S11JLD6 S11JLD62As
250 S13JLD6s S13JLD62As

Undervoltage Trip Combinations


1 Undervoltage Trip and 1 Undervoltage Trip and
Control Voltage 1 Undervoltage Trip 1 Auxiliary Switch 2 Auxiliary Switches

S01JLD6 AC DC Catalog Number Catalog Number Catalog Number


120 U01JLD6 U01JLD62A U01JLD62AA
208 U02JLD6s U02JLD62As U02JLD62AAs
240 U03JLD6 U03JLD62As U03JLD62AAs
480 U06JLD6 U06JLD64As U06JLD64AAs
024 U13JLD6 U13JLD62A U13JLD62AA
048 U14JLD6s U14JLD62As U14JLD62AAs
125 U10JLD6s U10JLD62As U10JLD62AAs
250 U12JLD6s U12JLD62As U12JLD62AAs

Auxiliary Switch Combinations


Maximum
Voltage 1 Form C 2 Form C
AC DC Catalog Number Catalog Number
480 250 A01JLD64 A02JLD64
— 24 A01JLDLV A02JLDLV
7

Alarm Switch Combinations


MOLDED CASE
CIRCUIT BREAKERS

Maximum 1 Alarm Switch and 1 Alarm Switch and


Voltage 1 Alarm Switch 1 Auxiliary Switch 2 Auxiliary Switches
AC DC Catalog Number Catalog Number CatalogNumber
480 250 B01JLD64 A01JLD64B A02JLD64B

ETU Testing Unit


Breaker Type Description Catalog Number
SJD, SLD, SMD, Power Stick EPSP18V
SND, SPD Spare cable for Power Stick COMPCA
The EPSP18V Power Stick is a hand-held, battery-operated power supply
that can be used for trip testing the Sensitrip IV electronic trip units.
Requires two 9V batteries.

Note: Accessory modules can only be added to right s Built to order. Allow 6–8 weeks for delivery.
side pole of solid state SJD and SLD frame circuit
breakers. No accessories can be added if
mechanical interlock is used. All accessories on this
page are useable on superseded JD2, JJ6, JL6, HJ6,
SJL, LJ6, LL6, HL6 and SLL circuit breakers.

7-110 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 05/31/18

Molded Case Circuit Breakers


LD 600A Frame Sentron Series Selection

Type LXD6-A ad Blue Label Ordering Information


Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Complete Breaker Unassembled
2-Pole (3-Pole Width) 3-Pole with Lugs
Continuous Prices of LD6, HLD6, and HHLD6
600V AC 250V DC 600V AC 500V DC
Current Rating breakers include frame, trip, and
@ 40° C Catalog Number Catalog Number both line and load lugs (TA2J6500).
450 LXD62B450n LXD63B450 When ordered by these catalog
500 LXD62B500n LXD63B500 numbers, the customer will receive
600 LXD62B600 LXD63B600 the frame, trip and lugs separately
packaged. For applications requiring
different lugs, order individual items
Type LD6-Ad Blue Label as needed.
Interchangeable Trip Complete Breaker Assembled with-
Continuous Complete Breaker out Lugs
Current Rating Unassembled w/Lugs Frame Only Trip Unit Only Prices of LXD6, HLXD6, HHLXD6,
@ 40°C Catalog Number Catalog Number Catalog Number and CLD6 include frame with non-
interchangeable trip unit installed
2-Pole 600V AC, 250V DC (3-Pole Width) only. Order required lugs separately.
250 LD62B250n JD62T250n For line and load lugs (TA2J6500)
300 LD62B300n JD62T300n installed, add suffix “L” to catalog
350 LD62B350n JD62T350n number (add 2 times list price of
400 LD62B400 LD62F600 JD62T400 lugs for each pole).
450 LD62B450n LD62T450n
500 LD62B500n LD62T500n 100% Rated (3-pole only)
600 LD62B600 LD62T600 Types LXD6 and HLXD6 breakers
3-Pole 600V AC, 500V DC b are available with 100% ratings.
To order add suffix “H” to catalog
250 LD63B250 JD63T250
300 LD63B300 JD63T300
number, and 10% to list price. 100%
350 LD63B350 JD63T350
rated LD breakers require the use of
400 LD63B400 LD63F600 JD63T400
90°C Cu cable sized at 75°C
450 LD63B450 LD63T450 ampacity and lugs TC1J6600
500 LD63B500 LD63T500 or TC2J6500.
600 LD63B600 LD63T600 50°C Applications see page 7-146.
400Hz Applications see page 7-146.
Interrupting Ratings
RMS Symmetrical Amperes (KA) Shipping Weights
UL 489 AIR (File E10848) IEC 947-2e Number of Number per Shipping
Breaker Volts AC (50/60Hz) Volts DC Volts AC (50/60Hz) Poles Carton Weight (lbs.)

7
Type 240 480 600 250 500 c 220/240 380/415 500 LXD6, LD6, HLD6, HHLD6
(lcu) (lcs) (lcu) (lcs) (lcu) (lcs) Assembled Breaker (less terminals)
LD6-A, LXD6-A 065 035 025 30 (2-P) 25 (3-P) 065 033 040 20 — — 2 1 17.5

CIRCUIT BREAKERS
MOLDED CASE
3 1 19.5
HLD6-A, HLXD6-A 100 065 035 30 (2-P) 35 (3-P) 100 050 065 33 — —
LD6, HLD6, HHLD6 Frame Only
HHLD6, HHLXD6 200 100 050 — — — — — — — —
2 1 14
CLD6-A 200 150 100 — 50 (3-P) — — — — — — 3 1 15.5
LD6, HHLD6 Trip Unit Only
Instantaneous Adjustment Trip Range 2
3
1
1
03.5
04
Nominal Instantaneous Values CLD6 Complete Assembled Breaker
+20% +20% (less terminals)
Breaker Ampere Tolerance Tolerance 3 1 31.5
Rating Low 2 3 4 5 6 7 High
250-300 1250 1430 1610 1790 1960 2140 2320 2500
350-450 2000 2290 2570 2860 3140 3430 3710 4000 Lugs For 75°C Wire c
500-600 3000 3430 3800 4290 4710 5140 5570 6000 Cables
Catalog per Wire
Number Lug Range
TA2J6500 1, 2 #3/0 500 kcmil Cu
2 #4/0 500 kcmil Al
n Built to order. Allow 2–3 weeks for delivery. TC2J6500 2 #3/0-500 kcmil Cu
a Type LXD6A circuit breakers are UL Listed for reverse TA1L6750 1 500-750 kcmil Al
fed applications. 1 500-600 kcmil Cu
b When
 wired as shown on page 7-4, this circuit breaker is
UL listed and rated for use on 500V DC ungrounded
TC1J6600 1 #3/0-600 kcmil Cu
UPS systems only. Compression Lug
c See Note: A, page 7-143.
Modifications page 7-146 CCL600 1 500 kcmil Cu/Al
d HACR rated.
e Only applicable to interchangable trip unit types: Enclosures Section 6
LXD6, HLXD6. Accessories pages 7-114 and 7-150 to 7-155
Note: LD frame qualified to UL489 supplement SB “NAVAL”.
See page 7-146 for additional information.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-111
Molded Case Circuit Breakers
LD 600A Frame Sentron Series Selection/Dimensions

Type HLD6-A, HLXD6-Abcf Black Label


Interchangeable Trip
Continuous Complete Breaker
Current Rating Unassembled w/Lugs Frame Only Trip Unit Only D1

@ 40°C Catalog Number Catalog Number Catalog Number �

2-Pole 600V AC, 250V DC (3-Pole Width)


250 HLD62B250n JD62T250n L
300 HLD62B300n JD62T300n
350 HLD62B350n JD62T350n L
400 HLD62B400n HLD62F600n JD62T400
450 HLD62B450n LD62T450n
500 HLD62B500n LD62T500n
600 HLD62B600n LD62T600
3-Pole 600V AC, 500V DC ae
250 HLD63B250 JD63T250 D D
300 HLD63B300 JD63T300
350 HLD63B350 JD63T350 Figure 1 Figure 2
400 HLD63B400 HLD63F600 JD63T400
450 HLD63B450 LD63T450
500 HLD63B500 LD63T500 Dimensions (in inches)
600 HLD63B600 LD63T600
To
Handle
Type HHLD6, HHLXD6bcf Black Label Breaker
Type W L D D1
2-Pole 600V AC (3-Pole Width) Figure 1
250 HHLD62B250n JD62T250n LXD6-A, LD6-A
300 HHLD62B300n JD62T300n HLD6-A
7.5 11 4 5.44
350 HHLD62B350n JD62T350n HHLD6, HHLXD6,
400 HHLD62B400n HHLD62F600n JD62T400 LXD6–ETI,d SLD6, SHLD6
450 HHLD62B450n HHLD62T450n Figure 2
500 HHLD62B500n HHLD62T500n CLD6, 7.5 17.86 4 5.44
600 HHLD62B600n HHLD62T600n CLD6-ETI,d SCLD6
3-Pole 600V AC
250 HHLD63B250 JD63T250 Enclosures: (except SCLD6)
300 HHLD63B300 JD63T300
350 HHLD63B350 JD63T350 Type Catalog Number
400 HHLD63B400 HHLD63F600 JD63T400
450 HHLD63B450n HHLD63T450n 1 LD6N1
3R LD6N3R
500 HHLD63B500n HHLD63T500n
12 LD6N12
7

600 HHLD63B600n HHLD63T600n


4X LD6SS4
7,9 ED6
MOLDED CASE
CIRCUIT BREAKERS

Neutral W60993

Type CLD6-Acf
Fuseless Current Limiting Red Label
Non-Interchangeable Trip (Assembled Circuit Breaker
Without Lugs)
Continuous 2-Pole 3-Pole
Current Rating 600V AC/250V DC 600V AC/500V DC
@ 40°C Catalog Number Catalog Number
450 For 2-pole application CLD63B450n
500 use outside poles of CLD63B500
600 3-pole circuit breaker CLD63B600

For inches / millimeters conversion, see Application Data section.

n Built to order. Allow 2–3 weeks for delivery. b For complete assembled 3-pole HLD6 or HHLD6 type cType HLXD6, HHLXD6, & CLD6 Circuit Breakers are UL
a When circuit breaker change the prefix identifier HLD6 or Listed for reverse feed applications.
wired as shown on page 7-4, this circuit breaker is
HHLD6 to HLXD6 or HHLXD6. Price is sum of frame and d LXD6-ETI, CLD6-ETI see page 7-130 for ordering information.

UL listed and rated for use on 500V DC ungrounded
trip units prices, e.g. price of HLXD63B400 is the price of e CE Applies to non-interchangeable type HLXD only.
UPS systems only.
HLD63F600 plus the price of LD63T600. Order the f HACR rated.
terminal connectors separately.

7-112 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 10/31/18

Molded Case Circuit Breakers


SLD 600A Frame Digital Solid State Sentron Sensitrip IV Series Selection

Current Limiting
Type SLD6-B Type SHLD6-B Type SCLD6-B
Blue Label Black Label Red Label
Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC
Current Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
Rating (Advanced trip unit)a (Basic trip unit) (Advanced trip unit)a (Basic trip unit) (Advanced trip unit)a (Basic trip unit)
300 SLD6A300LI SLD6B300LI SHLD6A300LI SHLD6B300LI SCLD6A300LI SCLD6B300LI
400 SLD6A400LI SLD6B400LI SHLD6A400LI SHLD6B400LI SCLD6A400LI SCLD6B400LI
500 SLD6A500LI SLD6B500LI SHLD6A500LI SHLD6B500LI SCLD6A500LI SCLD6B500LI
600 SLD6A600LI SLD6B600LI SHLD6A600LI SHLD6B600LI SCLD6A600LI SCLD6B600LI
300 SLD6A300LIG SLD6B300LIG SHLD6A300LIG SHLD6B300LIG SCLD6A300LIG SCLD6B300LIG
400 SLD6A400LIG SLD6B400LIG SHLD6A400LIG SHLD6B400LIG SCLD6A400LIG SCLD6B400LIG
500 SLD6A500LIG SLD6B500LIG SHLD6A500LIG SHLD6B500LIG SCLD6A500LIG SCLD6B500LIG
600 SLD6A600LIG SLD6B600LIG SHLD6A600LIG SHLD6B600LIG SCLD6A600LIG SCLD6B600LIG
300 SLD6A300LSI SLD6B300LSI SHLD6A300LSI SHLD6B300LSI SCLD6A300LSI SCLD6B300LSI
400 SLD6A400LSI SLD6B400LSI SHLD6A400LSI SHLD6B400LSI SCLD6A400LSI SCLD6B400LSI
500 SLD6A500LSI SLD6B500LSI SHLD6A500LSI SHLD6B500LSI SCLD6A500LSI SCLD6B500LSI
600 SLD6A600LSI SLD6B600LSI SHLD6A600LSI SHLD6B600LSI SCLD6A600LSI SCLD6B600LSI
300 SLD6A300LSIG SLD6B300LSIG SHLD6A300LSIG SHLD6B300LSIG SCLD6A300LSIG SCLD6B300LSIG
400 SLD6A400LSIG SLD6B400LSIG SHLD6A400LSIG SHLD6B400LSIG SCLD6A400LSIG SCLD6B400LSIG
500 SLD6A500LSIG SLD6B500LSIG SHLD6A500LSIG SHLD6B500LSIG SCLD6A500LSIG SCLD6B500LSIG
600 SLD6A600LSIG SLD6B600LSIG SHLD6A600LSIG SHLD6B600LSIG SCLD6A600LSIG SCLD6B600LSIG

Trip Unit Adjustable Functions Ordering Information


Short Short
Suffix Cont Long Instan- Short Time Time Ground Ground Pricing information for all Digital
Letter Trip Current Time taneous Time Fixed
2
lt Fault Fault Sentron Series SLD Frames is
Code Type Setting Delay Pick Up Pick Up Delay Delay Pick Up Delay for complete breaker only – price
LI LI u u u required lugs as separate items –
LIG LIG u u u u u lugs are suitable for 75°C Wire.
LSI LSI u u u u u u
SLD6, SHLD6 and SCLD6 are
LSIG LSIG u u u u u u u u
acceptable for reverse connection
application.

7
Interrupting Ratings Neutral Transformers
Shipping Weights

CIRCUIT BREAKERS
MOLDED CASE
RMS Symmetrical kA
UL 489 (File E10848) Ampere Rating Catalog Number
Breaker
300 N03SJD Breaker Number per Shipping
Type 240V AC 480V AC 600V AC
Type Carton Weight (lbs)
400 N04SJD
SLD6-B 65 35 25
500 N05SLD SLD6-B 1 20
SHLD6-B 100 65 35
600 N06SLD SHLD6-B 1 20
SCLD6-B 200 150 100
SCLD6-B 1 33

Note: “G” suffix in catalog number denotes circuit For ordering information and terminal connectors see a Advanced trip unit equipped with DAS / Maintenance
breaker for 3-phase, 3-wire circuits. page 7-111; for enclosures, see page 7-112. Mode. Requires customer-supplied 24V external power
For 3-phase, 4-wire, order correct 4th wire (neutral) 100% Rated – Not available in SLD6 Frame. supply, maintenance switch and light.
transformer as separate and additional item.
All breakers built to order. Allow 2-3 weeks for delivery.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-113
Revised on 12/31/19

Molded Case Circuit Breakers


Internal Accessories Selection

Accessories for: Shunt Trip Combinations


JD 400A Frame 1 Shunt Trip and
Control Voltage 1 Shunt Trip 1 Auxiliary Switch
LD 600A Frame
AC DC Catalog Number Catalog Number
LMD 800A Frame
SJD 400A Frame 024 S17JLD6 —
048 S18JLD6s —
SLD 600A Frame
120 S01JLD6 S01JLD62A
240 S03JLD6 S03JLD62A
277 S15JLD6s S15JLD64As
480 S04JLD6 —
012 S16JLD6s S16JLD62As
024 S07JLD6 S07JLD62A
048 S09JLD6s S09JLD62A
125 S11JLD6 S11JLD62As
250 S13JLD6s S13JLD62As

Undervoltage Trip Combinations


1 Undervoltage Trip and 1 Undervoltage Trip and
Control Voltage 1 Undervoltage Trip 1 Auxiliary Switch 2 Auxiliary Switches

S01JLD6 AC DC Catalog Number Catalog Number Catalog Number


120 U01JLD6 U01JLD62A U01JLD62AA
208 U02JLD6s U02JLD62As U02JLD62AAs
240 U03JLD6 U03JLD62As U03JLD62AAs
480 U06JLD6 U06JLD64As U06JLD64AAs
024 U13JLD6 U13JLD62A U13JLD62AA
048 U14JLD6s U14JLD62As U14JLD62AAs
125 U10JLD6s U10JLD62As U10JLD62AAs
250 U12JLD6s U12JLD62As U12JLD62AAs

Auxiliary Switch Combinations


Maximum
Voltage 1 Form C 2 Form C
AC DC Catalog Number Catalog Number
480 250 A01JLD64 A02JLD64
— 24 A01JLDLV A02JLDLV
7

Alarm Switch Combinations


MOLDED CASE
CIRCUIT BREAKERS

Maximum 1 Alarm Switch and 1 Alarm Switch and


Voltage 1 Alarm Switch 1 Auxiliary Switch 2 Auxiliary Switches
AC DC Catalog Number Catalog Number CatalogNumber
480 250 B01JLD64 A01JLD64B A02JLD64B

ETU Testing Unit


Breaker Type Description Catalog Number
SJD, SLD, SMD, Power Stick EPSP18V
SND, SPD Spare cable for Power Stick COMPCA
The EPSP18V Power Stick is a hand-held, battery-operated power supply
that can be used for trip testing the Sensitrip IV electronic trip units.
Requires two 9V batteries.

Note: Accessory modules can only be added to right s Built to order. Allow 6–8 weeks for delivery.
side pole of solid state SJD and SLD frame circuit
breakers. No accessories can be added if
mechanical interlock is used. All accessories on this
page are useable on superseded JD2, JJ6, JL6, HJ6,
SJL, LJ6, LL6, HL6 and SLL circuit breakers.

7-114 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Molded Case Circuit Breakers
LMD 800A Frame Sentron Series Selection

Type LMXD6 ad Blue Label Ordering Information


Non-Interchangeable Trip (Assembled Circuit Breaker Complete Breaker Unassembled
without Lugs) with Lugs
Continuous Prices of LMD6 and HLMD6 breakers
Current Rating 2-Pole (3-Pole Width) 3-Pole include frame, trip, and both line
@ 40°C Catalog Number Catalog Number
and load lugs (TA3K500). These
500 — LMXD63B500n
catalog numbers include the frame,
600 LMXD62B600n LMXD63B600
trip and lugs separately packaged.
700 LMXD62B700n LMXD63B700
For applications requiring different
800 LMXD62B800 LMXD63B800
lugs, order individual items as
needed.
Type LMD6 d Blue Label Complete Breaker Assembled
Interchangeable Trip without Lugs
Continuous Complete Breaker Prices of LMXD6 and HLMXD6
Current Rating Unassembled w/Lugs Frame Only Trip Unit Only include frame with
@ 40°C Catalog Number Catalog Number Catalog Number non-interchangeable trip unit
2-Pole 600V AC, 250V DC (3-Pole Width) installed only. Order required lugs
500 LMD62B500n LMD62T500n separately. For line and load lugs
600 LMD62B600n LMD62F800n LMD62T600n (TA3K500) installed, add suffix “L”
700 LMD62B700n LMD62T700n to catalog number (add 2 times list
800 LMD62B800n LMD62T800n price of lugs for each pole).
3-Pole 600V AC, 500V DC b 50°C Applications see page 7-146.
500 LMD63B500n LMD63T500n 400Hz Applications see page 7-146.
600 LMD63B600n LMD63F800 LMD63T600n
700 LMD63B700n LMD63T700n
800 LMD63B800 LMD63T800 Shipping Weights
Number of Number per Shipping
Poles Carton Weight (lbs.)
Instantaneous Adjustment Trip Range LMD6, HLMD6, LMXD6, HLMXD6
Complete Breaker (less terminals)
Nominal Instantaneous Values
2 1 53
Ampere Rating Low +/- 20% 2 3 4 5 6 7 High +/- 20% 3 1 61.5
Tolerance Tolerance
LMD6, HLMD6 Frame Only
500-600 3000 3430 3860 4290 4710 5140 5570 6000
2 1 42.25
700-800 3200 3500 3700 4200 4700 6400 7300 8000 3 1 46

7
LMD6, HLMD6 Trip Unit Only
2 1 4.5

CIRCUIT BREAKERS
MOLDED CASE
3 1 6.5

Lugsc for 75°C Wire


Cables
Catalog per Wire
Number Lug Range
TA2K500 1, 2 #1-500 kcmil Cu / Al
TA3K500 1-3 #1/0-500 kcmil Cu / Al
TA2N750 1, 2 500-750 kcmil Cu / Al

n Built to order. Allow 2–3 weeks for delivery. c See Note: A, page 7-143.
a LMXD6 circuit breakers are UL Listed for reverse
d HACR rated. Modifications page 7-146
connected applications. Enclosures Section 6
bWhen wired as shown on page 7-4, this circuit breaker is Accessories pages 7-117 and 7-150 to 7-155
UL listed and rated for use on 500VDC ungrounded UPS
systems only.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-115
Molded Case Circuit Breakers
LMD 800A Frame Sentron Series Selection/Dimensions

Type HLMXD6 ad Black Label


Non-Interchangeable Trip (Assembled Circuit Breaker
Without Lugs)
Continuous 2-Pole 3-Pole
Current Rating 600V AC/250V DC 600V AC/500V DC
@ 40°C Catalog Number Catalog Number
500 HLMXD63B500n
600 For 2-pole application HLMXD63B600n
use outside poles of
700 3-pole circuit breaker HLMXD63B700n
800 HLMXD63B800

Type HLMD6 d Black Label


Interchangeable Trip
Continuous Complete Breaker
Current Rating Unassembled Frame Only Trip Unit Only
@ 40°C Catalog Number Catalog Number Catalog Number
2-Pole 600V AC, 250V DC (3-Pole Width)
500 HLMD62B500n LMD62T500n
600 HLMD62B600n LMD62T600n
HLMD62F800n
700 HLMD62B700n LMD62T700n
800 HLMD62B800n LMD62T800n
3-Pole 600V AC, 500V DC c
500 HLMD63B500 LMD63T500 n
600 HLMD63B600 LMD63T600 n
HLMD63F800
700 HLMD63B700 LMD63T700 n
800 HLMD63B800 LMD63T800

Interrupting Ratings
UL 489A IR
RMS Symmetrical Amperes (KA)
Dimensions (in inches)
Volts AC Volts DC Breaker
Breaker Type W L D D1
Type 240 480 600 250 500
LMD6,
7

LMD6, LMXD6 65 50 25 30 (2-P) 25 (3-P)


LMXD6,
HLMD6, HLMXD6 100 065 050 30 (2-P) 50 (3-P) HLMD6, 7.5 16 4.5 5.93
HLMXD6
MOLDED CASE
CIRCUIT BREAKERS

LMXD6-ETI b

Enclosures
Type Catalog Number
1 LMD1
3R LMD3R
12 LMD12n
Neutral W63623

For inches / millimeters conversion, see Application Data section.

n Built to order. Allow 2–3 weeks for delivery. c When wired as shown on page 7-4, this circuit breaker
a HLMXD6 is UL listed and rated for use on 500VDC ungrounded
circuit breakers are UL Listed for reverse
UPS systems only.
connection applications. d HACR rated.
b LMXD6-ETI, see page 7-130 for catalog information.

7-116 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 12/31/19

Molded Case Circuit Breakers


Internal Accessories Selection

Accessories for: Shunt Trip Combinations


JD 400A Frame 1 Shunt Trip and
Control Voltage 1 Shunt Trip 1 Auxiliary Switch
LD 600A Frame
AC DC Catalog Number Catalog Number
LMD 800A Frame
SJD 400A Frame 024 S17JLD6 —
048 S18JLD6s —
SLD 600A Frame
120 S01JLD6 S01JLD62A
240 S03JLD6 S03JLD62A
277 S15JLD6s S15JLD64As
480 S04JLD6 —
012 S16JLD6s S16JLD62As
024 S07JLD6 S07JLD62A
048 S09JLD6s S09JLD62A
125 S11JLD6 S11JLD62As
250 S13JLD6s S13JLD62As

Undervoltage Trip Combinations


1 Undervoltage Trip and 1 Undervoltage Trip and
Control Voltage 1 Undervoltage Trip 1 Auxiliary Switch 2 Auxiliary Switches

S01JLD6 AC DC Catalog Number Catalog Number Catalog Number


120 U01JLD6 U01JLD62A U01JLD62AA
208 U02JLD6s U02JLD62As U02JLD62AAs
240 U03JLD6 U03JLD62As U03JLD62AAs
480 U06JLD6 U06JLD64As U06JLD64AAs
024 U13JLD6 U13JLD62A U13JLD62AA
048 U14JLD6s U14JLD62As U14JLD62AAs
125 U10JLD6s U10JLD62As U10JLD62AAs
250 U12JLD6s U12JLD62As U12JLD62AAs

Auxiliary Switch Combinations


Maximum
Voltage 1 Form C 2 Form C
AC DC Catalog Number Catalog Number
480 250 A01JLD64 A02JLD64
— 24 A01JLDLV A02JLDLV

7
Alarm Switch Combinations

CIRCUIT BREAKERS
MOLDED CASE
Maximum 1 Alarm Switch and 1 Alarm Switch and
Voltage 1 Alarm Switch 1 Auxiliary Switch 2 Auxiliary Switches
AC DC Catalog Number Catalog Number CatalogNumber
480 250 B01JLD64 A01JLD64B A02JLD64B

ETU Testing Unit


Breaker Type Description Catalog Number
SJD, SLD, SMD, Power Stick EPSP18V
SND, SPD Spare cable for Power Stick COMPCA
The EPSP18V Power Stick is a hand-held, battery-operated power supply
that can be used for trip testing the Sensitrip IV electronic trip units.
Requires two 9V batteries.

Note: Accessory modules can only be added to right s Built to order. Allow 6–8 weeks for delivery.
side pole of solid state SJD and SLD frame circuit
breakers. No accessories can be added if
mechanical interlock is used. All accessories on this
page are useable on superseded JD2, JJ6, JL6, HJ6,
SJL, LJ6, LL6, HL6 and SLL circuit breakers.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-117
Revised on 12/31/19

Molded Case Circuit Breakers


MD 800A Frame Sentron Series Selection

Type MXD6 af Blue Label Ordering Information


Non-Interchangeable Trip (Assembled Circuit Breaker Complete Breaker Unassembled
Without Lugs) with Lugs
Continuous
2-Poleb 3-Pole
Pricing information for MD6 and
Current Rating HMD6 breakers includes frame, trip,
@ 40°C Catalog Number Catalog Number
and both line and load lugs
600 MXD62B600n MXD63B600 (TA3K500). When ordered by these
700 MXD62B700n MXD63B700 catalog numbers, the customer will
800 MXD62B800n MXD63B800 receive the frame, trip and lugs
separately packaged. For
Type MD6 f Blue Label applications requiring different lugs,
order individual items as needed.
Interchangeable Trip
Complete Breaker Assembled with-
Complete Breaker
Continuous
Unassembled with Lugs Frame Only Trip Unit Only
out Lugs
Current Rating Prices of MXD6, HMXD6 and
@ 40°C Catalog Number Catalog Number Catalog Number
CMD6 include frame with
b
2-Pole 600V AC, 250V DC non-interchangeable trip units
500 MD62B500n MD62T500n installed only. Order required lugs
600 MD62B600n MD62T600n separately. For line and load lugs
MD62F800n (TA3K500) installed, add suffix “L”
700 MD62B700n MD62T700n
800 MD62B800n MD62T800n to catalog number (add 2 times list
c price of lugs for each pole).
3-Pole 600V AC, 500V DC
500 MD63B500 MD63T500 100% Ratede 3-Pole Only
600 MD63B600 MD63T600 Types MXD6, HMXD6 and CMD6
700 MD63B700
MD63F800
MD63T700
breakers are available with 100%
800 MD63B800 MD63T800
ratings. To order add suffix “H” to
catalog number, and 10% to list
price. 100% rated MD breakers
Lugs d require the use of 90°C cable
Catalog Cables Lugs Wire sized at 75°C ampacity and lugs
Number Per Lug Per Kit Range 3TA4P8500 or 3TA2N8750.
TA2K500 1-2 1 #1-500 kcmil Cu/ Al
50°C Applications see page 7-146.
TA3K500 1-3 1 1/0-500 kcmil Cu/ Al
TC2K500 1-2 1 #1-500 kcmil Cu 400Hz Applications see page 7-146.
Kits
2TA2N8750 1-2 2 500-750 kcmil Cu/ Al Shipping Weights
3TA2N8750 3
7

Number of Number per Shipping


2TA3N8750 1-3 2 500-750 kcmil Cu/ Al Poles Carton Weight (lbs.)
3TA3N8750 3
MOLDED CASE
CIRCUIT BREAKERS

MD6, HMD6, HMXD6, CMD6 Complete Breaker


2TA4N8500 1-4 2 250-500 kcmil Cu/ Al Assembled (less lugs)
3TA4N8500 3 2 1 53
2TA4P8500 1-4 2 250-500 kcmil Cu/Al 3 1 61.5
3TA4P8500 3 MD6, HMD6 Frame Only
2 1 42.25
Instantaneous Adjustment Trip Range 3 1 46
Ampere Nominal Instantaneous Values MD6, HMD6 Trip Unit Only
Rating Low +/- 20% 2 3 4 5 6 7 High +/- 20% 2 1 4.5
Tolerance Tolerance 3 1 6.5
500 3000 3430 3860 4280 4710 5140 5570 6000 SMD6 Breaker
600–800 4000 4570 5140 5710 6280 6850 7420 8000 3 1 61.5

Enclosures
Type Catalog Number
1 MND61
3R MND63
12 MND612n
Neutral W63623
n Built to order. Allow 2–3 weeks for delivery. d See Note: A, page 7-143.
e 80% rated breakers with the CE mark will also be
MXD6 circuit breakers are UL Listed for reverse
a
connection applications. marked in the 100% rated version.
b 2-pole
f HACR rated.
 Modifications page 7-146
units available in 3-pole width only.
cWhen wired as shown on page 7-4, this circuit breaker Note: MD frame qualified to UL489 supplement B “NAVAL”. Enclosures Section 6
is UL listed and rated for use on 500V DC ungrounded See page 7-146 for additional information. Accessories pages 7-121 and 7-150 to 7-155
UPS systems.

7-118 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 05/31/18

Molded Case Circuit Breakers


MD 800A Frame Sentron Series Selection/Dimensions

Type HMXD6 ae Black Label


Non-Interchangeable Trip (Assembled Circuit Breaker
Without Lugs)
Continuous 2-Pole 3-Pole
Current Rating 600V AC/250V DC 600V AC/500V DC
@ 40°C Catalog Number Catalog Number
600 For 2-pole application HMXD63B600n
700 use outside poles of HMXD63B700n
3-pole circuit breaker
800 HMXD63B800

Type HMD6 e Black Label


Interchangeable Trip
Continuous Complete Breaker
Current Rating Unassembled w/Lugs Frame Only Trip Unit Only
@ 40°C Catalog Number Catalog Number Catalog Number
2-Pole 600V AC, 250V DC b
500 HMD62B500n MD62T500n
600 HMD62B600n HMD62F800n MD62T600n
700 HMD62B700n MD62T700n
800 HMD62B800n MD62T800n
3-Pole 600V AC, 500V DC d
500 HMD63B500 MD63T500
600 HMD63B600 HMD63F800 MD63T600
700 HMD63B700 MD63T700
800 HMD63B800 MD63T800

Type CMD6 ae
Fuseless Current Limiting Red Label
Non-Interchangeable Trip (Assembled Circuit Breaker
Without Lugs) Lug
Continuous 2-Pole 3-Pole
600V AC/250V DC 600V AC/500V DC When wire lug shield NDTS is used.
Current Rating
Note: NDTS lug shields are required when oversized lugs
@ 40°C Catalog Number Catalog Number

7
are used. The kits include the NDTS shield.
600 For 2-pole application CMD63B600n
700 use outside poles of CMD63B700n

CIRCUIT BREAKERS
MOLDED CASE
800
3-pole circuit breaker
CMD63B800 Dimensions (in inches)
(To
Breaker Handle)
Interrupting Ratings Type W L D D1
MD6, MXD6, HMD6,
UL 489 AIR—File E10848 IEC 947-2 AIRf HMXD6, CMD6,
RMS Symmetrical Amperes (KA) Volts AC (50/60HZ) MXD6-ETI, CMD6-ETI, 9 16 6 8.25
Volts AC Volts DC 220/240 380/415 500 SMD6-B, SHMD6-B,
Breaker and SCMD6-B
Type 240 480 600 250 500 d (lcu) (lcs) (lcu) (lcs) (lcu) (lcs
with lug shields 9 24 6 8.25
MD6, MXD6 065 050 25 30 (2-P) 25 (3-P) 065 033 040 20 — —
HMD6, HMXD6 100 065 50 30 (2-P) 50 (3-P) 100 050 065 33 — —
CMD6 200 100 65 — 50 (3-P) — — — — — —

For inches / millimeters conversion, see Application Data section.

n Built to order. Allow 2–3 weeks for delivery. d When wired as shown on page 7-4, this circuit breaker is
a HMXD6 UL listed and rated for use on 500V DC ungrounded UPS
and CMD circuit breakers are UL listed for
systems only.
reverse connection applications. e HACR rated.
b 2-pole units available in 3-pole width only.
f Only applicable to interchangable trip unit types:
c MXD6-ETI, CMD6-ETI see page 7-130 for catalog information.
MXD6, HMXD6

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-119
Revised on 12/31/19

Molded Case Circuit Breakers


SMD 800A Frame Digital Solid State Sentron Sensitrip IV Series Selection

Current Limiting
Type SMD6 Type SHMD6-B Type SCMD6-B
Blue Label Black Label Red Label
Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC
Current Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
Rating (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit)
600 SMD6A600LI SMD6B600LI SHMD6A600LI SHMD6B600LI SCMD6A600LI SCMD6B600LI
700 SMD6A700LI SMD6B700LI SHMD6A700LI SHMD6B700LI SCMD6A700LI SCMD6B700LI
800 SMD6A800LI SMD6B800LI SHMD6A800LI SHMD6B800LI SCMD6A800LI SCMD6B800LI
600 SMD6A600LIG SMD6B600LIG SHMD6A600LIG SHMD6B600LIG SCMD6A600LIG SCMD6B600LIG
700 SMD6A700LIG SMD6B700LIG SHMD6A700LIG SHMD6B700LIG SCMD6A700LIG SCMD6B700LIG
800 SMD6A800LIG SMD6B800LIG SHMD6A800LIG SHMD6B800LIG SCMD6A800LIG SCMD6B800LIG
600 SMD6A600LSI SMD6B600LSI SHMD6A600LSI SHMD6B600LSI SCMD6A600LSI SCMD6B600LSI
700 SMD6A700LSI SMD6B700LSI SHMD6A700LSI SHMD6B700LSI SCMD6A700LSI SCMD6B700LSI
800 SMD6A800LSI SMD6B800LSI SHMD6A800LSI SHMD6B800LSI SCMD6A800LSI SCMD6B800LSI
600 SMD6A600LSIG SMD6B600LSIG SHMD6A600LSIG SHMD6B600LSIG SCMD6A600LSIG SCMD6B600LSIG
700 SMD6A700LSIG SMD6B700LSIG SHMD6A700LSIG SHMD6B700LSIG SCMD6A700LSIG SCMD6B700LSIG
800 SMD6A800LSIG SMD6B800LSIG SHMD6A800LSIG SHMD6B800LSIG SCMD6A800LSIG SCMD6B800LSIG

SMD 800A Frame – 100% Rateda Current Limiting


Type SMD6-B Type SHMD6-B Type SCMD6-B
Blue Label Black Label Red Label
Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC
Current Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
Rating (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit)
600 SMD6A600LIH SMD6B600LIH SHMD6A600LIH SHMD6B600LIH SCMD6A600LIH SCMD6B600LIH
700 SMD6A700LIH SMD6B700LIH SHMD6A700LIH SHMD6B700LIH SCMD6A700LIH SCMD6B700LIH
800 SMD6A800LIH SMD6B800LIH SHMD6A800LIH SHMD6B800LIH SCMD6A800LIH SCMD6B800LIH
600 SMD6A600LIGH SMD6B600LIGH SHMD6A600LIGH SHMD6B600LIGH SCMD6A600LIGH SCMD6B600LIGH
700 SMD6A700LIGH SMD6B700LIGH SHMD6A700LIGH SHMD6B700LIGH SCMD6A700LIGH SCMD6B700LIGH
800 SMD6A800LIGH SMD6B800LIGH SHMD6A800LIGH SHMD6B800LIGH SCMD6A800LIGH SCMD6B800LIGH
600 SMD6A600LSIH SMD6B600LSIH SHMD6A600LSIH SHMD6B600LSIH SCMD6A600LSIH SCMD6B600LSIH
700 SMD6A700LSIH SMD6B700LSIH SHMD6A700LSIH SHMD6B700LSIH SCMD6A700LSIH SCMD6B700LSIH
800 SMD6A800LSIH SMD6B800LSIH SHMD6A800LSIH SHMD6B800LSIH SCMD6A800LSIH SCMD6B800LSIH
600 SMD6A600LSIGH SMD6B600LSIGH SHMD6A600LSIGH SHMD6B600LSIGH SCMD6A600LSIGH SCMD6B600LSIGH
700 SMD6A700LSIGH SMD6B700LSIGH SHMD6A700LSIGH SHMD6B700LSIGH SCMD6A700LSIGH SCMD6B700LSIGH
7

800 SMD6A800LSIGH SMD6B800LSIGH SHMD6A800LSIGH SHMD6B800LSIGH SCMD6A800LSIGH SCMD6B800LSIGH

Ordering Information
Lugs for 75° C Wire b
MOLDED CASE
CIRCUIT BREAKERS

Pricing information for all Digital Sentron Series MD frames is for Catalog Cables Wire Each kit contains
complete breaker only. Price requires lugs or lug kits as separate items. Number per Lug Range the following:
Lugs are suitable for 75°C wire or as noted. Connector wire ranges TA2K500 2 #1-500 kcmil Cu/Al 3TA4P8500 -
and cavities are established in conjunction with Table 6.1.4.2.1 of UL TA3K500 3 #1-500 kcmil Cu/Al 3 connectors plus
489 standards. Choose actual connector for circuit breakers based on 1 NDTS end barrier
customer requirements. TC2K500 2 #1-500 kcmil Cu
Kits (3 lugs/kit) 3TA3N8750 -
Recommended Terminal Connectors
3 connectors plus
Breaker Frame Ampere Rating Connector or Connector Kit 3TA4N8500 4 250-500 kcmil Cu/Al
1 NDTS end barrier
MD 500-600 TA2K500 3TA4P8500 4 250-500 kcmil Cu/Al
3TA2N8750 -
MD 700-800 TA3K500 3TA2N8750 2 500-750 kcmil Cu/Al 3 connectors plus
Types SMD6-B, SHMD6-B and SCMD6-B are acceptable for reverse 3TA3N8750 3 500-750 kcmil Cu/Al 1 NDTS end barrier
connection applications

Trip Unit Adjustable Functions Interrupting Ratings Neutral


Suffix Cont Long Instan- Short Short Ground Ground RMS Symmetrical kA Transformers
Letter Trip Current Time taneous Time Time Fault Fault UL 489 (File E10848)
Code Type Setting Delay Pick Up Pick Up Delay Pick Up Delay Breaker 240V 480V 600V Ampere
LI LI u u u Type AC AC AC Rating Catalog Number
LIG LIG u u u u u SMD6-B 65 50 25 600 N06SMDA
LSI LSI u u u u u SHMD6-B 100 65 50 700 N07SMDA
LSIG LSIG u u u u u u u SCMD6-B 200 100 65 800 N08SMDA
Note: “G” suffix in catalog number denotes circuit aU
 se 2-3TA4P8500 for 3-pole. These kits are rated for cA
 dvanced trip unit equipped with DAS / Maintenance
breaker for 3-phase, 3-wire circuits. 90°C wire. 90°C cable must be used, and sized per Mode. Requires customer-supplied 24V external power
For 3-phase, 4-wire, order correct 4th wire (neutral) 75°C ampacity. supply, maintenance switch and light.
transformer as separate and additional item.  or additional information, see Note: A, page 7-143.
bF

All breakers built to order. Allow 2-3 weeks for delivery.


Enclosures Section 6
Accessories pages 7-121 and 7-150 to 7-155

7-120 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 12/31/19

Molded Case Circuit Breakers


Internal Accessories Selection

Accessories for: Shunt Trip Combinations


MD/SMD 800A Frame 1 Shunt Trip and
ND/SND 1200A Frame Control Voltage 1 Shunt Trip 1 Auxiliary Switch
PD/SPD 1600A Frame AC DC Catalog Number Catalog Number
RD 2000A Frame 120 S01MN6 S01MN64A
208 S02MN6s —
240 S03MN6 S03MN64As
277 S15MN6s S15MN64As
480 S04MN6s S04MN64As
600 S06MN6s —
012 S16MN6s S16MN64As
024 S07MN6 S07MN64A
048 S09MN6s —
125 S11MN6 S11MN64As
250 S13MN6s S13MN64As

Undervoltage Trip Combinations


1 Undervoltage Trip and 1 Undervoltage Trip and
Control Voltage 1 Undervoltage Trip 1 Auxiliary Switch 2 Auxiliary Switches

AC DC Catalog Number Catalog Number Catalog Number


S01MN6 120 U01MN6 U01MN64A U01MN64AA
208 U02MN6s U02MN64As U02MN64AAs
Accessory modules can mount in either 240 U03MN6s U03MN64As U03MN64AAs
left hand or right hand poles of all circuit 277 U15MN6s U15MN64As U15MN64AAs
breakers, including solid state. Exception: 480 U04MN6s U04MN64As U04MN64AAs
600 U06MN6s — —
when mechanical interlock is used.
024 U07MN6 U07MN64A U07MN64AA
Accessories cannot be mounted in left
048 U09MN6s U09MN64As U09MN64AAs
pole. 125 U11MN6s U11MN64As U11MN64AAs
250 U13MN6s U13MN64As U13MN64AAs

Auxiliary Switch Combinations


Maximum
Voltage 1 Form C 2 Form C
AC DC Catalog Number Catalog Number

7
480 250 A01MN64 A02MN64
— 24 A01MNDLVs A02MNDLVs

CIRCUIT BREAKERS
MOLDED CASE
Alarm Switch Combinations
Maximum 1 Alarm Switch and 1 Alarm Switch and
Voltage 1 Alarm Switch 1 Auxiliary Switch 2 Auxiliary Switches
AC DC Catalog Number Catalog Number Catalog Number
480 250 B00MN64 A01MN64B A02MN64B

ETU Testing Unit


Breaker Type Description Catalog Number
SJD, SLD, SMD, Power Stick EPSP18V
SND, SPD Spare cable for Power Stick COMPCA
The EPSP18V Power Stick is a hand-held, battery-operated power supply
that can be used for trip testing the Sensitrip IV electronic trip units.
Requires two 9V batteries.

s Built to order. Allow 6–8 weeks for delivery.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-121
Revised on 12/31/19

Molded Case Circuit Breakers


ND 1200A Frame Sentron Series Selection

Type NXD6 ah Blue Label Ordering Information


Non-Interchangeable Trip (Assembled Circuit Breaker Complete Breaker Unassembled
Without Lugs) with Lugs
Continuous 2-Pole 3-Pole Prices of ND6 and HND6 breakers
Current Rating 600V AC/250V DC 600V AC/500V DC include frame, trip, and both line and
@ 40°C Catalog Number Catalog Number load lugs (3TA4N8500). These catalog
0900 NXD62B900n NXD63B900 numbers are the frame, trip and lugs
1000 NXD62B100n NXD63B100 separately packaged. For applications
1200 NXD62B120n NXD63B120 requiring different lugs, order
individual items as needed.
Complete Breaker Assembled
Type ND6 h Blue Label without Lugs
Interchangeable Trip Prices of NXD6, HNXD6, and
CND6 include frame with
Continuous Complete Breaker
Unassembled with Lugs Frame Only Trip Unit Only non-interchangeable trip units
Current Rating installed only. Order required
@ 40°C Catalog Number Catalog Number Catalog Number
terminal connectors separately.
2-Pole 600V AC, 250V DC b For line and load lugs (3TA4N8500)
0800 ND62B800n MD62T800n installed, add suffix “L” to catalog
0900 ND62B900n ND62T900n number (add 2 times list price of
ND62F120 lug kit).
1000 ND62B100n ND62T100n
1200 ND62B120 ND62T120 100% Rated (3-Pole only)g
3-Pole 600V AC, 500V DC c Types NXD6, HNXD6 and CND6
0800 ND63B800 MD63T800 breakers are available with 100%
0900 ND63B900 ND63T900
ratings. To order, add suffix “H” to
1000 ND63B100
ND63F120
ND63T100
catalog number, and add 10% to
list price. 100% rated ND breakers
1200 ND63B120 ND63T120
require 90°C cable sized at 75°C
ampacity and lug kit 3TA4P8500
Interrupting Ratings or 3TA3N8750.
RMS Symmetrical Amperes (KA) 50°C Applications see page 7-146.
UL 489 A IR IEC 947-2i 400Hz Applications see page 7-146.
Breaker Volts AC Volts DC Volts AC (50/60HZ)
Type 240 480 600 250 500 c 220/240 380/415 500
(lcu) (lcs) (lcu) (lcs) (lcu) (lcs)
Lugs f
Catalog Cables Wire
ND6, NXD6 65 50 25 30 (2-P) 25 (3-P) 65 33 40 20 — —
Number per Lug Range
7

HND6, HNXD6 100 65 50 30 (2-P) 50 (3-P) 100 50 65 33 — —


TA2K500 2 #1-500 kcmil Cu /Al
CND6 200 100 65 — 50 (3-P) — — — — — — TA3K500 3 #1-500 kcmil Cu /Al
MOLDED CASE
CIRCUIT BREAKERS

TC2K500 2 #1-500 kcmil Cu


Instantaneous Adjustment Trip Range Kits (2 Kits required per breaker)
2TA4P8500 d
Nominal Instantaneous Values 4 250-500 kcmil Cu /Al
3TA4P8500 d
+20% +20% 2TA4N8500 e
Breaker Ampere Tolerance Tolerance 4 250-500 kcmil Cu /Al
Rating Low 2 3 4 5 6 7 High 3TA4N8500 e
800 4000 4570 5140 5710 6280 6850 7420 08000 2TA2N8750
2 500-750 kcmil Cu /Al
3TA2N8750
900-1200 5000 5715 6430 7145 7860 8575 9290 10000
2TA3N8750
3 500-750 kcmil Cu /Al
3TA3N8750

Enclosures
Type Catalog Number
1 MND61
3R MND63
12 MND612 n
Neutral W63623

n Built to order. Allow 2–3 weeks for delivery. e Use 2 – 3TA4N8500 for 3-pole or 2 – 2TA4N8500 for
a NXD6 2-pole. Rated for 75°C cable.
circuit breakers are UL listed for reverse f See Note: A, page 7-143.

connection applications. g 80% rated breakers with the CE mark will also be
b 2-pole units available in 3-pole width only.
marked in the 100% rated version. Modifications page 7-146
c When wired as shown on page 7-4, this circuit breaker is
h HACR rated. Enclosures Section 6
UL listed and rated for use on 500VDC ungrounded UPS
systems only.
i Only applicable to interchangable trip unit types: Accessories pages 7-125 and 7-150 to 7-155
d Use 2 – 3TA4P8500 kits for 3-pole, or 2 – 2TA4P8500 NXD6, HNXD6.
Note: ND frame qualified to UL489 supplement B “NAVAL”.
kits for 2-pole. Rated for 90° C cable. Use for 100% rated
See page 7-146 for additional information.
breakers.

7-122 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 02/06/18

Molded Case Circuit Breakers


ND 1200A Frame Sentron Series Selection/Dimensions

Type HNXD6 ad Black Label


Non-Interchangeable Trip (Assembled Circuit Breaker
Without Lugs)
Continuous 2-Pole 3-Pole
Current Rating 600V AC/250V DC 600V AC/500V DC
@ 40°C Catalog Number Catalog Number
0900 For 2-pole application HNXD63B900
1000 use outside poles of HNXD63B100
1200 3-pole circuit breaker HNXD63B120

Type HND6 d Black Label


Interchangeable Trip
Continuous Complete Breaker
Current Rating Unassembled with Lugs Frame Only Trip Unit Only
NXD63B120
@ 40°C Catalog Number Catalog Number Catalog Number
2-Pole 600V AC, 250V DC b
0800
0900
For 2-pole application use outside poles of 3-pole circuit breaker
1000
1200
3-Pole 600V AC, 500V DC c
0800 HND63B800 MD63T800
0900 HND63B900 ND63T900
HND63F120
1000 HND63B100 ND63T100
1200 HND63B120 ND63T120

Type CND6 ad
Fuseless Current Limiting Red Label
Non-Interchangeable Trip (Assembled Circuit Breaker)
Lugs
Continuous
Current Rating 2-Pole 3-Pole
When lugs shield NDTS is used.
@ 40°C Catalog Number Catalog Number
Note: NDTS lug shields are required when oversized lugs

7
0900 For 2-pole application, CND63B900n TA4P8500 or TA4N8500 are used. The kits include
1000 use outside poles of CND63B100 the NDTS shield.
3-pole circuit breaker
1200 CND63B120

CIRCUIT BREAKERS
MOLDED CASE
Dimensions (in inches)
Shipping Weights Breaker
Type W L D D1
Number of Number per Shipping ND6, NXD6, HND6,
Poles Carton Weight (lbs.)
HNXD6, CND6,
ND6, HND6, NXD6, HNXD6, CND6 9 16 6 8.25
SND6-B, SHND6-B,
Assembled Breaker (less terminals)
and SCND6-B
2 1 53
3 1 61.5 with NDTS
lug shield 9 24 6 8.25
ND6, HND6 Frame Only
2 1 42.25
3 1 46
ND6, HND6 Trip Unit Only
2 1 04.5
3 1 06.5

For inches / millimeters conversion, see Application Data section.

n Built to order. Allow 2–3 weeks for delivery. c When wired as shown on page 7-4, this circuit breaker is
a HNXD6 UL listed and rated for use on 500V DC ungrounded
and CND6 circuit breakers are UL Listed for
UPS systems only.
reverse connection applications. d HACR rated.
b 2-pole units available in 3-pole width only.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-123
Revised on 02/28/19

Molded Case Circuit Breakers


SND 1200A Frame Digital Solid State Sentron Sensitrip IV Seriesb Selection

Current Limiting
Type SND6-B Type SHND6-B Type SCND6-B
Blue Label Black Label Red Label
Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC
Current Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
Rating (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit)
800 SND6A800LI SND6B800LI SHND6A800LI SHND6B800LI SCND6A800LI SCND6B800LI
1000 SND6A100LI SND6B100LI SHND6A100LI SHND6B100LI SCND6A100LI SCND6B100LI
1200 SND6A120LI SND6B120LI SHND6A120LI SHND6B120LI SCND6A120LI SCND6B120LI
800 SND6A800LIG SND6B800LIG SHND6A800LIG SHND6B800LIG SCND6A800LIG SCND6B800LIG
1000 SND6A100LIG SND6B100LIG SHND6A100LIG SHND6B100LIG SCND6A100LIG SCND6B100LIG
1200 SND6A120LIG SND6B120LIG SHND6A120LIG SHND6B120LIG SCND6A120LIG SCND6B120LIG
800 SND6A800LSI SND6B800LSI SHND6A800LSI SHND6B800LSI SCND6A800LSI SCND6B800LSI
1000 SND6A100LSI SND6B100LSI SHND6A100LSI SHND6B100LSI SCND6A100LSI SCND6B100LSI
1200 SND6A120LSI SND6B120LSI SHND6A120LSI SHND6B120LSI SCND6A120LSI SCND6B120LSI
800 SND6A800LSIG SND6B800LSIG SHND6A800LSIG SHND6B800LSIG SCND6A800LSIG SCND6B800LSIG
1000 SND6A100LSIG SND6B100LSIG SHND6A100LSIG SHND6B100LSIG SCND6A100LSIG SCND6B100LSIG
1200 SND6A120LSIG SND6B120LSIG SHND6A120LSIG SHND6B120LSIG SCND6A120LSIG SCND6B120LSIG

SND 1200A Frame – 100% Rateda Current Limiting


Type SND6-B Type SHND6-B Type SCND6-B
Blue Label Black Label Red Label
Max 3-Pole, 600V AC 3-Pole, 600V AC 3-Pole, 600V AC
Current Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
Rating (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit)
800 SND6A800LIH SND6B800LIH SHND6A800LIH SHND6B800LIH SCND6A800LIH SCND6B800LIH
1000 SND6A100LIH SND6B100LIH SHND6A100LIH SHND6B100LIH SCND6A100LIH SCND6B100LIH
1200 SND6A120LIH SND6B120LIH SHND6A120LIH SHND6B120LIH SCND6A120LIH SCND6B120LIH
800 SND6A800LIGH SND6B800LIGH SHND6A800LIGH SHND6B800LIGH SCND6A800LIGH SCND6B800LIGH
1000 SND6A100LIGH SND6B100LIGH SHND6A100LIGH SHND6B100LIGH SCND6A100LIGH SCND6B100LIGH
1200 SND6A120LIGH SND6B120LIGH SHND6A120LIGH SHND6B120LIGH SCND6A120LIGH SCND6B120LIGH
800 SND6A800LSIH SND6B800LSIH SHND6A800LSIH SHND6B800LSIH SCND6A800LSIH SCND6B800LSIH
1000 SND6A100LSIH SND6B100LSIH SHND6A100LSIH SHND6B100LSIH SCND6A100LSIH SCND6B100LSIH
1200 SND6A120LSIH SND6B120LSIH SHND6A120LSIH SHND6B120LSIH SCND6A120LSIH SCND6B120LSIH
800 SND6A800LSIGH SND6B800LSIGH SHND6A800LSIGH SHND6B800LSIGH SCND6A800LSIGH SCND6B800LSIGH
7

1000 SND6A100LSIGH SND6B100LSIGH SHND6A100LSIGH SHND6B100LSIGH SCND6A100LSIGH SCND6B100LSIGH


1200 SND6A120LSIGH SND6B120LSIGH SHND6A120LSIGH SHND6B120LSIGH SCND6A120LSIGH SCND6B120LSIGH
MOLDED CASE
CIRCUIT BREAKERS

Trip Unit Adjustable Functions


Short
Suffix Cont Long Instan- Short Time Short Ground Ground
Letter Trip Current Time taneous Time Fixed Time I2t Fault Fault
Code Type Setting Delay Pick Up Pick Up Pick Up Delay Pick Up Delay
LI LI u u u
LIG LIG u u u u u
LSI LSI u u u u u u
LSIG LSIG u u u u u u u u

Interrupting Ratings Neutral Transformers


Breaker RMS Symmetrical kA UL 489 (File E10848) Ampere Catalog
Type 240V AC 480V AC 600V AC Rating Number
SND6-B 65 50 25 800 N08SMDA
SHND6-B 100 65 50 1000 N10SNDA
SCND6-B 200 100 65 1200 N12SNDA

For inches / millimeters conversion, see Application Data section.


For ordering information and terminal connectors, All breakers built to order. Allow 2–3 weeks for delivery. c Advanced trip unit equipped with DAS / Maintenance
and enclosures, see page 7-122. a  Use Mode. Requires customer-supplied 24V external power
2-3TA4P8500 for 3-pole. These kits are rated for
Note: “G” suffix in catalog number denotes circuit supply, maintenance switch and light.
90°C wire. 90°C cable must be used, and sized per 75°C
breaker for 3-phase, 3-wire circuits.
ampacity.
For 3-phase, 4-wire, order correct 4th wire (neutral) b  SND6, SHND6 and SCND6 circuit breakers are UL Listed
transformer as separate and additional item.
for reverse connection applications.

7-124 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 12/31/19

Molded Case Circuit Breakers


Internal Accessories Selection

Accessories for: Shunt Trip Combinations


MD/SMD 800A Frame 1 Shunt Trip and
ND/SND 1200A Frame Control Voltage 1 Shunt Trip 1 Auxiliary Switch
PD/SPD 1600A Frame AC DC Catalog Number Catalog Number
RD 2000A Frame 120 S01MN6 S01MN64A
208 S02MN6s —
240 S03MN6 S03MN64As
277 S15MN6s S15MN64As
480 S04MN6s S04MN64As
600 S06MN6s —
012 S16MN6s S16MN64As
024 S07MN6 S07MN64A
048 S09MN6s —
125 S11MN6 S11MN64As
250 S13MN6s S13MN64As

Undervoltage Trip Combinations


1 Undervoltage Trip and 1 Undervoltage Trip and
Control Voltage 1 Undervoltage Trip 1 Auxiliary Switch 2 Auxiliary Switches

AC DC Catalog Number Catalog Number Catalog Number


S01MN6 120 U01MN6 U01MN64A U01MN64AA
208 U02MN6s U02MN64As U02MN64AAs
240 U03MN6s U03MN64As U03MN64AAs
Accessory modules can mount in either 277 U15MN6s U15MN64As U15MN64AAs
left hand or right hand poles of all circuit 480 U04MN6s U04MN64As U04MN64AAs
breakers, including solid state. Exception: 600 U06MN6s — —
when mechanical interlock is used. 024 U07MN6 U07MN64A U07MN64AA
Accessories cannot be mounted in left 048 U09MN6s U09MN64As U09MN64AAs
pole. 125 U11MN6s U11MN64As U11MN64AAs
250 U13MN6s U13MN64As U13MN64AAs

Auxiliary Switch Combinations


Maximum
Voltage 1 Form C 2 Form C
AC DC Catalog Number Catalog Number

7
480 250 A01MN64 A02MN64
— 24 A01MNDLVs A02MNDLVs

CIRCUIT BREAKERS
MOLDED CASE
Alarm Switch Combinations
Maximum 1 Alarm Switch and 1 Alarm Switch and
Voltage 1 Alarm Switch 1 Auxiliary Switch 2 Auxiliary Switches
AC DC Catalog Number Catalog Number Catalog Number
480 250 B00MN64 A01MN64B A02MN64B

ETU Testing Unit


Breaker Type Description Catalog Number
SJD, SLD, SMD, Power Stick EPSP18V
SND, SPD Spare cable for Power Stick COMPCA
The EPSP18V Power Stick is a hand-held, battery-operated power supply
that can be used for trip testing the Sensitrip IV electronic trip units.
Requires two 9V batteries.

s Built to order. Allow 6–8 weeks for delivery.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-125


Molded Case Circuit Breakers
PD 1600A Frame Sentron Series Selection

Type PXD6 b Non-Interchangeable Trip e Ordering Instructions


3-Pole 600V AC, 250-500V DC a Blue Label Complete Breaker Unassembled
with Lugs
Continuous Complete Breaker Assembled
Current (Frame/Trip Unit Only) Mounting Assembly Lugs (6 required) Prices of PD6, HPD6, RD6, and HRD6
Rating @ 40°C Catalog Number Catalog Number Catalog Number type breakers include frame, trip,
1200 PXD63B120n MB9301 mounting base (MB9301), and both
1400 PXD63B140n -or- TA5P600 line and load lugs (PD Frame –
1600 PXD63B160 MBR9302 TA5P600, RD Frame – TC5R600). When
ordered by these catalog numbers, the
customer will receive the frame, trip,
Type PD6 Interchangeable Trip e mounting assembly and lugs
3-Pole 600V AC, 250-500V DC a Blue Label separately packaged. For applications
requiring different mounting base or
Continuous Complete Breaker Mounting lugs, order individual items as needed.
Current Unassembled Frame Only Trip Unit Only Assembly Lugs (6 required)
Complete Breaker Assembled
Rating @ Catalog Catalog Catalog Catalog Catalog
40°C Number Number Number Number Number
without Lugs
1200 PD63B120n PD63T120n MB9301 Prices of PXD6, HPXD6, RXD6, HRXD6
1400 PD63B140 PD63F160 PD63T140 -or- TA5P600 and CPD6 type breakers include frame
1600 PD63B160 PD63T160 MBR9302 with non-interchangeable trip unit
installed only. Order required
mounting base and lugs separately.
Type HPXD6 b Non-Interchangeable Trip e 100% Rated (3-Pole only)
3-Pole 600V AC, 250-500V DC a Blue Label Types PXD6, HPXD6 breakers are
available with 100% ratings. To order
Continuous Current Complete Breaker Assembled (Frame/Trip Unit Only) add suffix “H” to catalog number,
Rating @ 40°C Catalog Number and 10% to list price. 100% PD
1200 HPXD63B120n breakers require 90˚ C cable sized
1400 HPXD63B140n at 75˚ C ampacity and TC5R600 lugs.
1600 HPXD63B160 RD 2000A Frames not available with
100% ratings.
Type HPD6 Interchangeable Trip e 50°C Applications see page 7-146.
3-Pole 600V AC, 250-500V DC a Black Label 400HZ Applications see page 7-146.

Continuous Complete Breaker Mounting


Current Unassembled Frame Only Trip Unit Only Assembly Lugs (6 required)
Rating @ Catalog Catalog Catalog Catalog Catalog
40°C Number Number Number Number Number
1200 HPD63B120n PD63T120n MB9301
Lugs (6 required per breaker)d
7

1400 HPD63B140 HPD63F160 PD63T140 -or- TA5P600


1600 HPD63B160 PD63T160 MBR9302 No of
Catalog Cables per
MOLDED CASE
CIRCUIT BREAKERS

Number Connector Wire Range


Type CPD6 Non-Interchangeable Trip e TA5P600
TC5R600
1-5
1-5
300-600 kcmil Cu/Al
300-600 kcmil Cu only
Fuseless Current Limiting TA4P750s 1-4 600-750 kcmil Cu/Al
TA6R600 1-6 300-600 kcmil Cu/Al
3-Pole 600V AC, 250-500V DC a Red Label
Continuous Current Complete Breaker Assembled (Frame/Trip Unit Only)
Rating @ 40°C Catalog Number
1200 CPD63B120n
1400 CPD63B140n
1600 CPD63B160n

Interrupting Ratings
UL 489 A IR
RMS Symmetrical KA
Volts AC Volts DC a
Breaker
Type 240 480 600 250 500
PD6, PXD6 65 50 25 30 (2P) 25 (3P)
HPD6, HPXD6 100 65 50 30 (2P) 50 (3P)
CPD6 200 100 65 30 (2P) 50 (3P)

n Built to order. Allow 2–3 weeks for delivery. UL listed and rated for use on 500V DC ungrounded UPS e HACR rated.
systems only. Note: PD frame qualified to UL489 supplement B “NAVAL”.
s Built to order. Allow 6–8 weeks for delivery. c PXD6, HPXD6 and CPD6 type circuit breakers are UL See page 7-146 for additional information.
a Use two outside poles of a 3-pole circuit breaker for 250V Listed for reverse feed applications.
b When wired as shown on page 7-4, this circuit breaker is d For additional information See Note: A, page 7-143.

7-126 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 05/31/18

Molded Case Circuit Breakers


SPD 1600A Frame Digital Solid State Sentron Sensitrip IV Series Selection/Dimensions

Ordering Information
Type SPD6-B Type SHPD6-B
Pricing information for all Digital
Blue Label Black Label Sentron Series PD frame unit is
for breaker only. Price required
Max 3-Pole, 600V AC 3-Pole, 600V AC mounting block assembly and
Current Catalog Number Catalog Number Catalog Number Catalog Number necessary terminal connectors
Rating (Advanced trip unit)c (Basic trip unit) (Advanced trip unit)c (Basic trip unit)
as separate items.
1400 SPD6A140LI SPD6B140LI SHPD6A140LI SHPD6B140LI
1600 SPD6A160LI SPD6B160LI SHPD6A160LI SHPD6B160LI SPD6-B and SHPD6-B are
1400 SPD6A140LIG SPD6B140LIG SHPD6A140LIG SHPD6B140LIG acceptable for reverse connection
1600 SPD6A160LIG SPD6B160LIG SHPD6A160LIG SHPD6B160LIG applications.
1400 SPD6A140LSI SPD6B140LSI SHPD6A140LSI SHPD6B140LSI
1600 SPD6A160LSI SPD6B160LSI SHPD6A160LSI SHPD6B160LSI
1400 SPD6A140LSIG SPD6B140LSIG SHPD6A140LSIG SHPD6B140LSIG Lugsa
1600 SPD6A160LSIG SPD6B160LSIG SHPD6A160LSIG SHPD6B160LSIG No. of
cables
Catalog per con- Wire
Trip Unit Adjustable Functions Number nector Range
TA5P600 1-5 pcs. 300-600 kcmil Cu/Al
Short Short
Suffix Cont Long Instan- Short Time Time Ground Ground TC5R600 1-5 pcs. 300-600 kcmil Cu Only
2
Letter Trip Current Time taneous Time Fixed lt Fault Fault TA6R600 1-6 pcs. 300-600 kcmil Cu/Al
Code Type Setting Delay Pick Up Pick Up Delay Delay Pick Up Delay
LI LI u u u
LIG LIG u u u u u Neutral Transformers
LSI LSI u u u u u u
LSIG LSIG u u u u u u u u Ampere Rating Catalog Number
1400 N14SPD
1600 N16SPD
Interrupting Mounting Block
Ratings (Required)b
Breaker RMS Symmetrical kA UL 489
Catalog Number
Enclosure
Type 240V AC 480V AC 600V AC
MB9301 Type Catalog Number
SPD6-B 65 50 25
SHPD6-B 100 65 50 MBR9302 1 PRD6N1

7
CIRCUIT BREAKERS
MOLDED CASE
All PD, RD Frames:

MB9301 (shown)
MBR9302 MBR9302 MB9301 MBR9302 MB9301

For inches / millimeters conversion, see Application Data section.

Note: “G” suffix in catalog number denotes circuit All breakers built to order. Allow 2–3 weeks for delivery. c Advanced trip unit equipped with DAS / Maintenance
breaker for 3-phase, 3-wire circuits. a For additional information, see Note: A, page 7-143. Mode. Requires customer-supplied 24V external power
For 3-phase, 4-wire, order correct 4th wire (neutral) b The PD frame circuit breaker requires the use of a supply, maintenance switch and light.
transformer as separate and additional item. connect-all mounting assembly to allow for placing
into service.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-127
Revised on 12/31/19

Molded Case Circuit Breakers


Internal Accessories Selection

Accessories for: Shunt Trip Combinations


MD/SMD 800A Frame 1 Shunt Trip and
ND/SND 1200A Frame Control Voltage 1 Shunt Trip 1 Auxiliary Switch
PD/SPD 1600A Frame AC DC Catalog Number Catalog Number
RD 2000A Frame 120 S01MN6 S01MN64A
208 S02MN6s —
240 S03MN6 S03MN64As
277 S15MN6s S15MN64As
480 S04MN6s S04MN64As
600 S06MN6s —
012 S16MN6s S16MN64As
024 S07MN6 S07MN64A
048 S09MN6s —
125 S11MN6 S11MN64As
250 S13MN6s S13MN64As

Undervoltage Trip Combinations


1 Undervoltage Trip and 1 Undervoltage Trip and
Control Voltage 1 Undervoltage Trip 1 Auxiliary Switch 2 Auxiliary Switches

AC DC Catalog Number Catalog Number Catalog Number


S01MN6 120 U01MN6 U01MN64A U01MN64AA
208 U02MN6s U02MN64As U02MN64AAs
240 U03MN6s U03MN64As U03MN64AAs
Accessory modules can mount in either 277 U15MN6s U15MN64As U15MN64AAs
left hand or right hand poles of all circuit 480 U04MN6s U04MN64As U04MN64AAs
600 U06MN6s — —
breakers, including solid state. Exception:
024 U07MN6 U07MN64A U07MN64AA
when mechanical interlock is used.
048 U09MN6s U09MN64As U09MN64AAs
Accessories cannot be mounted in left 125 U11MN6s U11MN64As U11MN64AAs
pole. 250 U13MN6s U13MN64As U13MN64AAs

Auxiliary Switch Combinations


Maximum
Voltage 1 Form C 2 Form C
AC DC Catalog Number Catalog Number
7

480 250 A01MN64 A02MN64


— 24 A01MNDLVs A02MNDLVs
MOLDED CASE
CIRCUIT BREAKERS

Alarm Switch Combinations


Maximum 1 Alarm Switch and 1 Alarm Switch and
Voltage 1 Alarm Switch 1 Auxiliary Switch 2 Auxiliary Switches
AC DC Catalog Number Catalog Number Catalog Number
480 250 B00MN64 A01MN64B A02MN64B

ETU Testing Unit


Breaker Type Description Catalog Number
SJD, SLD, SMD, Power Stick EPSP18V
SND, SPD Spare cable for Power Stick COMPCA
The EPSP18V Power Stick is a hand-held, battery-operated power supply
that can be used for trip testing the Sensitrip IV electronic trip units.
Requires two 9V batteries.

s Built to order. Allow 6–8 weeks for delivery.

7-128 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Molded Case Circuit Breakers
RD 2000A Frame Sentron Series Selection

Type RXD6 d
3-Pole 600V AC, 250-500V DC a Blue Label
Non-Interchangeable Trip (Assembled Circuit Breaker Only Without Lugs)
Continuous Complete Breaker Assembled
Current (Frame/Trip Unit Only) Mounting Assembly Lugs (6 required)
Rating @ 40°C Catalog Number Catalog Number Catalog Number
1600 RXD63B160 MB9301
1800 RXD63B180 -or- TC5R600
2000 RXD63B200 MBR9302

Type RD6 d
3-Pole 600V AC, 250-500V DC a Blue Label
Interchangeable Trip (Unassembled Circuit Breaker with Lugs)
Continuous Complete Breaker Mounting
Current Unassembled Frame Only Trip Unit Only Assembly Lugs (6 required) RXD63B200
Rating @ Catalog Catalog Catalog Catalog Catalog
40°C Number Number Number Number Number
1600 RD63B160n RD63T160n MB9301 Mounting Block
1800 RD63B180 RD63F200 RD63T180 -or- TC5R600 Catalog
2000 RD63B200 RD63T200 MBR9302 Number Connection Points
MB9301 Front
Type HRXD6 d Black Label MBR9302 Rear

Complete Breaker Assembled (Frame/Trip Unit Only)


Continuous Current
Rating @ 40°C Catalog Number
Shipping Weights
1600 HRXD63B160n Number of Number per Shipping
1800 HRXD63B180n Poles Carton Weight (lbs.)
2000 HRXD63B200 PXD6, HPXD6, RXD6, HRXD6, CPD6
Assembled Breakers
3 1 61.5
Type HRD6 d Black Label PD6, HPD6, RD6, HRD6
Frame Only
Continuous Complete Breaker Mounting 3 1 55.0
Current Unassembled Frame Only Trip Unit Only Assembly Lugs (6 required) PD6, RD6
Rating @ Catalog Catalog Catalog Catalog Catalog Trip Unit Only
40°C Number Number Number Number Number 3 1 06.5
1600 HRD63B160n RD63T160n MB9301 Mounting Assembly

7
1800 HRD63B180 HRD63F200 RD63T180 -or- TC5R600 MB9301 1 53.0
2000 HRD63B200 RD63T200 MBR9302 MBR9302 1 50.9

CIRCUIT BREAKERS
MOLDED CASE
Interrupting Ratings Lugs (6 required per breaker)e
UL 489 A IR No of
RMS Symmetrical KA Catalog Cables per
Number Connector Wire Range
Breaker Volts AC Volts DC a TC5R600 1-5 300-600 kcmil Cu only
Type 240 480 600 250 500 TA6R600 1-6 300-600 kcmil Cu/Al
RD6, RXD6 65 50 25 30 (2P) 25 (3P)
HRD6, HRXD6 100 65 50 30 (2P) 50 (3P)

Instantaneous Adjustment Trip Range (PD / RD Frames)


Nominal Instantaneous Values
+20% +20%
Breaker Ampere Tolerance Tolerance
Rating Low 2 3 4 5 6 7 High
1200-2000 5000 5715 6430 7145 7860 8575 9790 10,000

n Built to order. Allow 2–3 weeks for delivery. b When wired as shown on page 7-4, this circuit breaker is d HACR rated.
UL listed and rated for use on 500V DC ungrounded e For additional information See Note: A, page 7-143.
s Built to order. Allow 6–8 weeks for delivery. UPS systems only. Note: RD frame qualified to UL489 supplement B “NAVAL”.
a Use
two outside poles of a 3-pole circuit breaker for c RXD6 and HRXD6 type circuit breakers are UL Listed for See page 7-146 for additional information.
250V DC applications. reverse feed applications.  For required mounting base (MB9301 or MBR9302) see
page 7-127.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-129
Revised on 02/28/19

Molded Case Circuit Breakers


Magnetic Trip Only — ETI Motor Circuit Protector Selection

Instantaneous Trip Range b Complete Circuit Breaker Without Lugs e


Breaker Ampere Catalog Number Catalog Number
Type Rating Minimum c Maximum c 2-Pole 3-Pole
001 002.6 00009 — ED63A001
002 007 00022 — ED63A002
003 010 00035 — ED63A003
005 016 00054 — ED63A005
010 030 00100 — ED63A010
ED6-A 025 055 00180 — ED63A025
600V AC 030 080 00270 — ED63A030
250V DC 040 115 00375 — ED63A040
050 180 00600 — ED63A050
100 315 01000 — ED63A100
125 500 01250 — ED63A125
SHIPPING: 03.8 lbs. each
001 002.6 00009 — CED63A001n
002 007 00022 — CED63A002n
003 010 00035 — CED63A003n
005 016 00054 — CED63A005n
010 030 00100 — CED63A010n
CED6-A 025 055 00180 — CED63A025n
600V AC 030 080 00270 — CED63A030n
250V DC 040 115 00375 — CED63A040n
050 180 00600 — CED63A050n
100 315 01000 — CED63A100n
125 500 01250 — CED63A125n
SHIPPING: 06 lbs. each
150 0400 00800 — FXD63L150n
FXD6 d 150 0800 01500 — FXD63A150
150 1100 02500 — FXD63H150
600V AC
250V DC 250 1100 02500 — FXD63A250
SHIPPING: 09 lbs. each
150 0400 00800 — CFD63L150n
CFD6 d 150 0800 01500 — CFD63A150n
150 1100 02500 — CFD63H150n
600V AC
250V DC 250 1100 02500 — CFD63A250n
SHIPPING: 12 lbs. each 12 lbs. each

JXD6(A)a 400
400
1250
2000
02500
04000

JXD62H400n
JXD63L400
JXD63H400
600V AC
250V DC SHIPPING: 16 lbs. each 20 lbs. each
7

CJD6 a 400
400
1250
2000
02500
04000


CJD63L400n
CJD63H400n
600V AC
MOLDED CASE
CIRCUIT BREAKERS

250V DC SHIPPING: 29.5 lbs. each 31.5 lbs. each

LXD6(A) a 600
600
2000
3000
04000
06000
LXD62L600n

LXD63L600n
LXD63H600
600V AC
250V DC SHIPPING: 16 lbs. each 20 lbs. each

CLD6 a 600
600
2000
3000
04000
06000


CLD63L600n
CLD63H600n
600V AC
250V DC SHIPPING: 31.5 lbs. each

LMXD6 d 800
800
2800
3200
06000
08000


LMXD63L800n
LMXD63A800
600V AC
250V DC SHIPPING: 35 lbs. each
800 3000 06000 — MXD63L800n
MXD6 d 800 4000 08000 — MXD63A800n
600V AC 800 5000 10000 — MXD63H800
250V DC
SHIPPING: 33 lbs. each
800 3000 06000 — CMD63L800n
CMD6 d 800 4000 08000 — CMD63A800n
600V AC 800 5000 10000 — CMD63H800n
250V DC
SHIPPING: 80 lbs. each

Important Information
Lug Information pages 7-143 to 7-145
ETI interrupting ratings are determined through combination tests with properly sized overload relays and contactors. Enclosures Section 6
e Connectors included when ordering by circuit breaker catalog number for HEM, ED and CED6 ETIs. Order ETI Accessories pages 7-150 to 7-155
circuit breaker and lugs (2 per pole) separately for the FXD6, CFD6, MXD6, CMD6, JXD6, CJD6, LXD6 and CLD6 ETI’s. Application data pages 7-131 to 7-132

n Built to order. Allow 2–3 weeks for delivery. bW


 hen applied on DC Circuits — Trip levels will increase tings are -20%/+20%
a2 approximately +15 to 20%. dF
 or 2-pole application use outside poles of 3-pole circuit
 -pole available in 3-pole width only. cT
 olerance-20%/+30% for lowest setting. All other set- breaker.

7-130 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 02/28/19

Molded Case Circuit Breakers


Motor Circuits Application

General continuous-current ratings of at least branch circuit. The adjustable


115% of motor full-load currents. The instantaneous-trip feature of the Siemens
Protection of Motor Circuits trip-setting positions are approximately ETI motor circuit protector provides for a
Molded case circuit breakers are used in 11 times motor full-load currents. The trip setting slightly above the peak
motor circuits as a disconnecting means suggested trip settings may have to be motor-inrush current. With this setting,
and for short-circuit protection. They adjusted upward to no higher than 1300% no delay is introduced in opening the
should be used in conjunction with of full-load current for non-design E type circuit when a fault occurs. This circuit
motor-running, over-current-protection motors, and no greater than 1700% of full breaker has no time-delay trip element.
devices, and should permit the motor load current for design E motors, to allow Therefore it must be used in conjunction
to start without nuisance tripping from for motor start-up due to inrush currents. with, and immediately ahead of, the
motor-inrush current. The circuit breaker Breaker Mounted Immediately Ahead motor-running overcurrent protective
should have a continuous-current rating device.
of Motor Starter
of not less than 115% of the motor Important: The information below does
full-load current. Siemens ETI motor circuit protectors are
not apply to all motor applications: it
recommended for use in combination
The recommended motor circuit is recommended that the user refer to
motor starters to provide selective
protectors (Siemens ETI instantaneous the National Electrical Code (NEC) for
short-circuit protection for the motor
only circuit breakers) listed have specific needs.

Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter)


3-Phase Induction Type Motors (Siemens ETI motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters).

Motor ETI Trip Setting ETI Trip Setting ETI Trip Setting
Full Load Catalog Adjust- Motor Full Catalog Adjust- Motor Full Catalog Adjust-
Amperes Number ment Amperes Load Amperes Number ment Amperes Load Amperes Number ment Amperes
.20 – .33 Low 2.6 8.84 – 14.22 Low 115 95.00 – 110.00 Low 1250
.34 – .45 2 4.5 14.23 – 19.60 2 185 110.00 – 124.00 2 1430
.46 – .56 ED63A001 3 6 19.61 – 24.99 ED63A040 3 255 138.00 – 151.00 JXD63L400 4 1790
.57 – .68 CED63A001 4 7.5 25.00 – 28.83 CED63A040 4 325 165.00 – 178.00 CJD63L400 6 2140
.69 – .81 High 9 28.84 – 34.00 High 375 178.00 – 192.00 7 2320
192.00 – 227.00 High 2500
.53 – .83 Low 7 13.84 – 23.06 Low 180
.84 – 1.14 2 11 23.07 – 31.52 2 300 154.00 – 176.00 Low 2000
1.15 – 1.45 ED63A002 3 15 31.53 – 39.99 ED63A050 3 410 176.00 – 198.00 2 2290
1.46 – 1.68 CED63A002 4 19 40.00 – 46.14 CED63A050 4 520 220.00 – 242.00 JXD63H400 4 2860
1.69 – 2.00 High 22 46.15 – 54.50 High 600 264.00 – 285.00 CJD63H400 6 3430
285.00 – 308.00 7 3710
.76 – 1.29 Low 10 24.23 – 41.52 Low 315 308.00 – 326.00 High 4000
1.30 – 1.75 2 17 41.53 – 56.91 2 540
1.76 – 2.29 ED63A003 3 23 56.92 – 68.45 ED63A100 3 740 155.00 – 176.00 Low 2000
2.30 – 2.68 CED63A003 4 30 68.46 – 76.91 CED63A100 4 890 176.00 – 198.00 2 2290
2.69 – 3.18 High 35 76.92 – 90.90 High 1000 220.00 – 242.00 LXD63L600 4 2860
264.00 – 285.00 CLD63L600 6 3430
1.23 – 1.99 Low 16 38.46 – 55.37 Low 500 285.00 – 308.00 7 3710
2.00 – 2.75 2 26 55.38 – 70.75 2 720 308.00 – 326.00 High 4000
2.76 – 3.52 ED63A005 3 36 70.76 – 84.60 ED63A125 3 920
3.53 – 4.14 CED63A005 4 46 84.61 – 96.14 CED63A125 4 1100 231.00 – 264.00 Low 3000
4.15 – 4.90 High 54 96.15 – 113.60 High 1250 264.00 – 292.00 2 3430

7
330.00 – 362.00 LXD63H600 4 4290
2.30 – 3.83 Low 30 30.76 – 35.37 Low 400 395.00 – 428.00 CLD63H600 6 5140
3.84 – 5.37 2 50 35.38 – 39.99 2 460 428.99 – 462.00 7 5570
5.38 – 6.52 ED63A010 3 70 44.51 – 49.23 FXD63L150 4 580 462.00 – 490.00 High 6000
6.53 – 7.68 CED63A010 4 85 53.84 – 58.45 CFD63L150 6 700

CIRCUIT BREAKERS
MOLDED CASE
7.69 – 9.10 High 100 58.46 – 63.06 7 760 215.00 – 238.00 Low 2800
63.07 – 74.50 High 820 238.00 – 261.00 2 3100
4.23 – 6.91 Low 55 261.00 – 284.00 3 3400
6.92 – 9.61 2 90 61.53 – 69.22 Low 800 308.00 – 369.00 LMXD63L800 5 4000
9.62 – 11.91 ED63A025 3 125 69.23 – 76.91 2 900 369.00 – 423.00 6 4800
11.92 – 13.83 CED63A025 4 155 84.61 – 92.29 FXD63A150 4 1100 423.00 – 462.00 7 5500
13.84 – 16.40 High 180 100.00 – 108.00 CFD63A150 6 1300 462.00 – 490.00 High 6000
108.00 – 115.00 7 1400
6.15 – 10.37 Low 80 115.00 – 136.00 High 1500 246.00 – 269.00 Low 3200
10.38 – 14.22 2 135 269.00 – 284.00 2 3500
14.23 – 18.06 ED63A030 3 185 85.00 – 100.00 Low 1100 284.00 – 323.00 3 3700
18.07 – 20.75 CED63A030 4 235 100.00 – 115.00 2 1300 362.00 – 492.00 LMXD63A800 5 4700
20.76 – 24.50 High 270 131.00 – 146.00 FXD63A250 4 1700 492.00 – 562.00 6 6400
162.00 – 177.00 CFD63A250 6 2100 562.00 – 616.00 7 7300
177.00 – 192.00 7 2300 616.00 – 660.00 High 8000
192.00 – 227.00 High 2500
231.00 – 264.00 Low 3000
264.00 – 292.00 2 3430
292.00 – 330.00 3 3800
362.00 – 395.00 MXD63L800 5 4710
428.00 – 462.00 CMD63L800 7 5570
462.00 – 490.00 High 6000
308.00 – 352.00 Low 4000
352.00 – 442.00 2 4570
442.00 – 447.00 3 5740
483.00 – 527.00 MXD63A800 5 6280
571.00 – 616.00 CMD63A800 7 7240
616.00 – 660.00 High 8000
385.00 – 440.00 Low 5000
495.00 – 550.00 MXD63H800 3 6430
605.00 – 660.00 CMD63H800 5 7860
660.00 – 695.00 6 8575

Note: Lowest instantaneous settings have a -20%/+30% tolerance and all


other settings have a -20%/+20% tolerance.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-131


Molded Case Circuit Breakers
Motor Circuits Application

Breaker Mounted at a Distance From circuit-breaker ratings in Table 2 provide Interrupt Ratings
Motor Starter adequate time delay for starting the For normal commercial purposes,
ET thermal-magnetic circuit breakers majority of three phase induction motors. available fault current can conveniently
conform to the National Electrical Code To determine the ampere ratings of the ET be obtained in the Interrupting
table 430-52 requirements for motor breaker to protect a motor feeder, add the Selector Tables.
branch and feeder circuit protection rating of the ET breaker used to protect
when properly applied in conjunction with the largest motor branch circuit in the
motor-running overcurrent protective group to the full-load currents of the
devices. The recommended remaining motors in the group.

Table 2 (When Breaker is Mounted at a Distance From Motor Starter)


3-Phase Induction Type Motors (EQ and ET circuit breakers (thermal-magnetic trip) for branch breaker use with alternating-current combination motor starters).

200 and 208V Motors 230V Motors 460V Motors 575V Motors
Motor 240V Circuit Breaker Data a 240V Circuit Breaker Data a 480V Circuit Breaker Data a 600V Circuit Breaker Data a
Horse-
power Breaker Catalog Ampere Breaker Catalog Ampere Breaker Catalog Ampere Breaker Catalog Ampere
Rating Type Number Rating Type Number Rating Type Number Rating Type Number Rating
0001⁄2 BQ3B015 015 BQ3B015 015 ED43B015 015 ED63B015 015
0003⁄4 BQ3B015 015 BQ3B015 015 ED43B015 015 ED63B015 015
001 BQ3B015 015 BQ3B015 015 ED43B015 015 ED63B015 015
BQ b
BQ b
ED4 ED6
001 ⁄2
1
BQ3B015 015 BQ3B015 015 ED43B015 015 ED63B015 015
002 BQ3B020 020 BQ3B015 015 ED43B015 015 ED63B015 015
003 BQ3B030 030 BQ3B020 020 ED43B015 015 ED63B015 015
005 BQ3B040 040 BQ3B030 030 ED43B015 015 ED63B015 015
007 ⁄2
1
BQ3B060 060 BQ3B050 050 ED43B030 030 ED63B020 020
010 BQ b
BQ3B070 070 BQ b
BQ3B070 070 ED4 ED43B030 030 ED6 ED63B030 030
015 BQ3B100 100 BQ3B090 090 ED43B040 040 ED63B035 035
020 BQ3B100 100 ED43B050 050 ED63B050 050
025 FXD63B125 125 FXD63B125 125 FXD63B090 090 FXD63B060 060
030 FXD63B150 150 FXD63B150 150 FXD63B100 100 FXD63B070 070
FXD6
040 FXD6 FXD63B175 175 FXD6 FXD63B175 175 FXD6 FXD63B125 125 FXD63B090 090
050 FXD63B200 200 FXD63B200 200 FXD63B150 150 FXD63B100 100
FXD63B225 225
060 JXD2 JXD23B300 300 — — — FXD6, FD6 FXD63B150 150 FXD6 FXD63B100 100
075 JXD2 JXD23B400 400 JXD2 JXD23B350 350 FXD6, FD6 FXD63B200 200 FXD6, FD6 FXD63B125 125
FD6 c
FD63B250 250
100 JXD2 JXD23B400 400 JXD2 JXD23B400 400 FXD6, FD6 FD63B175 175
JD6 c JD63B250 250
LD6 c
or LD63B600 LD6 c
or LD63B500 or FXD6, FD6 FXD63B200 200
125 600 500 JD6 c JD63B300 300
LMD6 LMD63B600 LMD6 LMD63B500 OR JD6 c JD63B200 200
LD6 c
or LD63B600 or LD63B600 or FXD6 or FXD63B225 225
150 600 LMD6 600 JD6 c
JD63B300 300
LMD6 LMD63B600 LMD63B600 JD6 c JD63B225 225
200 LMD6 LMD63B800 800 LMD6 LMD63B800 800 JD6 c
JD63B350 350 JD6 c
JD63B300 300
7

250 — — — — — — JD6 c JD63B400 400 JD6 c JD63B400 400


LD6 or
c
LD63B600 or 600
300 — — — — — — JD6 c JD63B400 400
LMD6 LMD63B600
MOLDED CASE
CIRCUIT BREAKERS

LD6 c or LD63B500 or
350 — — — — — — LMD6 LMD63B700 700 500
LMD6 LMD63B500
LD6 c or LD63B600 or
400 — — — — — — LMD6 LMD63B800 800 600
LMD6 LMD63B600
500 — — — — — — — — — LMD6 LMD63B800 800

a Theselection of breakers for this table is in accordance with b Forpanelboard applications, substitute the BL breaker for c Fornon-interchangeable trip applications, substitute the
Article 430, 2005 National Electric Code. Recommended the BQ, ED2 circuit breakers may also be used. FXD6 for the FD6, the JXD6 for the JD6, or the LXD6 for
circuit breakers are for full voltage starting, special the LD6.
consideration is necessary for reduced voltage starting.

7-132 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/28/19

Molded Case Circuit Breakers


Adjustable Installments Magnetic Trip Settings Application

Maximum Nominal ETI Motor Circuit Protector Thermal Magnetic


Breaker Continuous AC Adjustable Trip Range Catalog Number Catalog Number
Type Amperes Low 2 3 4 5 6 7 High 3-Pole 2-Pole 3-Pole
1 2.6 4.5 6 7.5 — — — 9 ED63A001 — —
2 7 11 15 19 — — — 22 ED63A002 — —
3 10 17 23 30 — — — 35 ED63A003 — —
5 16 26 36 46 — — — 54 ED63A005 — —
10 30 50 70 85 — — — 100 ED63A010 — —
ED6 25 55 90 125 155 — — — 180 ED63A025 — —
30 80 135 185 235 — — — 270 ED63A030 — —
40 115 185 255 325 — — — 375 ED63A040 — —
50 180 300 410 520 — — — 600 ED63A050 — —
100 315 540 740 890 — — — 1000 ED63A100 — —
125 500 720 920 1100 — — — 1250 ED63A125 — —
1 2.6 4.5 6 7.5 — — — 9 CED63A001n — —
2 7 11 15 19 — — — 22 CED63A002n — —
3 10 17 23 30 — — — 35 CED63A003n — —
5 16 26 36 46 — — — 54 CED63A005n — —
10 30 50 70 85 — — — 100 CED63A010n — —
CED6 25 55 90 125 155 — — — 180 CED63A025n — —
30 80 135 185 235 — — — 270 CED63A030n — —
40 115 185 255 325 — — — 375 CED63A040n — —
50 180 300 410 520 — — — 600 CED63A050 — —
100 315 540 740 890 — — — 1000 CED63A100 — —
125 500 720 920 1100 — — — 1250 CED63A125 — —
70 600 640 690 730 770 810 850 900 — FXD62B070 FXD63B070
80 600 640 690 730 770 810 850 900 — FXD62B080 FXD63B080
90 600 640 690 730 770 810 850 900 — FXD62B090 FXD63B090
100 700 770 840 920 990 1060 1140 1200 — FXD62B100 FXD63B100
110 700 770 840 920 990 1060 1140 1200 — FXD62B110 FXD63B110
125 800 900 1000 1100 1200 1300 1400 1500 — FXD62B125 FXD63B125
150 400 460 520 580 640 700 760 820 FXD63L150 — —
FXD6-A 150 800 900 1000 1100 1200 1300 1400 1500 FXD63A150 FXD62B150 FXD63B150
150 1100 1300 1500 1700 1900 2100 2300 2500 FXD63H150 — —
175 900 1060 1210 1370 1520 1780 1930 2000 — FXD62B175 FXD63B175
200 900 1060 1210 1370 1520 1780 1930 2000 — FXD62B200 FXD63B200
225 1100 1300 1500 1700 1900 2100 2300 2500 — FXD62B225 FXD63B225
250 1100 1300 1500 1700 1900 2100 2300 2500 FXD63A250 FXD62B250 FXD63B250
70 600 640 690 730 770 810 850 900 — FD62B070 FD63B070
80 600 640 690 730 770 810 850 900 — FD62B080 FD63B080
90 600 640 690 730 770 810 850 900 — FD62B090 FD63B090
100 700 770 840 920 990 1060 1140 1200 — FD62B100 FD63B100
110 700 770 840 920 990 1060 1140 1200 — FD62B110 FD63B110
FD6-A 125 800 900 1000 1100 1200 1300 1400 1500 — FD62B125 FD63B125
150 800 900 1000 1100 1200 1300 1400 1500 — FD62B150 FD63B150
175 900 1060 1210 1370 1520 1780 1930 2000 — FD62B175 FD63B175
200 900 1060 1210 1370 1520 1780 1930 2000 — FD62B200 FD63B200
225 1100 1300 1500 1700 1900 2100 2300 2500 — FD62B225 FD63B225
250 1100 1300 1500 1700 1900 2100 2300 2500 — FD62B250 FD63B250
70 600 640 690 730 770 810 850 900 — HFD62B070 HFD63B070
80 600 640 690 730 770 810 850 900 — HFD62B080 HFD63B080
90 600 640 690 730 770 810 850 900 — HFD62B090 HFD63B090
100 700 770 840 920 990 1060 1140 1200 — HFD62B100 HFD63B100
110 700 770 840 920 990 1060 1140 1200 — HFD62B110 HFD63B110
HFD6 125 800 900 1000 1100 1200 1300 1400 1500 — HFD62B125 HFD63B125

7
150 800 900 1000 1100 1200 1300 1400 1500 — HFD62B150 HFD63B150
175 900 1060 1210 1370 1520 1780 1930 2000 — HFD62B175 HFD63B175
200 900 1060 1210 1370 1520 1780 1930 2000 — HFD62B200 HFD63B200

CIRCUIT BREAKERS
MOLDED CASE
225 1100 1300 1500 1700 1900 2100 2300 2500 — HFD62B225 HFD63B225
250 1100 1300 1500 1700 1900 2100 2300 2500 — HFD62B250 HFD63B250
70 600 640 690 730 770 810 850 900 — — HHFD63B070
80 600 640 690 730 770 810 850 900 — — HHFD63B080
90 600 640 690 730 770 810 850 900 — — HHFD63B090
100 700 770 840 920 990 1060 1140 1200 — — HHFD63B100
110 700 770 840 920 990 1060 1140 1200 — — HHFD63B110
HHFD6 125 800 900 1000 1100 1200 1300 1400 1500 — — HHFD63B125
150 800 900 1000 1100 1200 1300 1400 1500 — — HHFD63B150
175 900 1060 1210 1370 1520 1780 1930 2000 — — HHFD63B175
200 900 1060 1210 1370 1520 1780 1930 2000 — — HHFD63B200
225 1100 1300 1500 1700 1900 2100 2300 2500 — — HHFD63B225
250 1100 1300 1500 1700 1900 2100 2300 2500 — — HHFD63B250
70 600 640 690 730 770 810 850 900 — CFD62B070 CFD63B070
80 600 640 690 730 770 810 850 900 — CFD62B080 CFD63B080
90 600 640 690 730 770 810 850 900 — CFD62B090 CFD63B090
100 700 770 840 920 990 1060 1140 1200 — CFD62B100 CFD63B100
110 700 770 840 920 990 1060 1140 1200 — CFD62B110 CFD63B110
125 800 900 1000 1100 1200 1300 1400 1500 — CFD62B125 CFD63B125
CFD6 150 400 460 520 580 640 700 760 820 CFD63L150 — —
150 800 900 1000 1100 1200 1300 1400 1500 CFD63A150 CFD62B150 CFD63B150
150 1100 1300 1500 1700 1900 2100 2300 2500 CFD63H150 — —
175 900 1060 1210 1370 1520 1780 1930 2000 — CFD62B175 CFD63B175
200 900 1060 1210 1370 1520 1780 1930 2000 — CFD62B200 CFD63B200
225 1100 1300 1500 1700 1900 2100 2300 2500 — CFD62B225 CFD63B225
250 1100 1300 1500 1700 1900 2100 2300 2500 CFD63A250 CFD62B250 CFD63B250

Note: T
 olerances for instantaneous trip points meet UL 489 Instantaneous trip adjustment is made through the n Built to order. Allow 2–3 weeks for delivery.
(7.3). Nominal AC instantaneous trip points are given breaker cover on all frame breakers. To change instan-
in the tables. For DC instantaneous trip points, add 15% taneous trip point on circuit breaker, depress indicating
to nominal values. knob, then rotate to desired position.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-133


Molded Case Circuit Breakers
Adjustable Instantaneous Magnetic Trip Settings Application

Maximum Nominal ETI Motor Circuit Protector Thermal Magnetic


Breaker Continuous AC Adjustable Trip Range Catalog Number Catalog Number
Type Amperes Low 2 3 4 5 6 7 High 3-Pole 2-Pole 3-Pole
200 1250 1430 1610 1790 1960 2140 2320 2500 — JXD22B200 JXD23B200
225 1250 1430 1610 1790 1960 2140 2320 2500 — JXD22B225 JXD23B225
JXD2(A) 250 1250 1430 1610 1790 1960 2140 2320 2500 — JXD22B250 JXD23B250
300 1250 1430 1610 1790 1960 2140 2320 2500 — JXD22B300 JXD23B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — JXD22B350 JXD23B350
400 2000 2290 2570 2860 3140 3430 3710 4000 — JXD22B400 JXD23B400
200 1250 1430 1610 1790 1960 2140 2320 2500 — JXD62B200 JXD63B200
225 1250 1430 1610 1790 1960 2140 2320 2500 — JXD62B225 JXD63B225
250 1250 1430 1610 1790 1960 2140 2320 2500 — JXD62B250 JXD63B250
JXD6(A)
300 1250 1430 1610 1790 1960 2140 2320 2500 — JXD62B300 JXD62B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — JXD62B350 JXD23B350
400 2000 2290 2570 2860 3140 3430 3710 4000 — JXD62B400 JXD23B400
200 1250 1430 1610 1790 1960 2140 2320 2500 — JD62B200 JD63B200
225 1250 1430 1610 1790 1960 2140 2320 2500 — JD62B225 JD63B225
250 1250 1430 1610 1790 1960 2140 2320 2500 — JD62B250 JD63B250
JD6(A) 300 1250 1430 1610 1790 1960 2140 2320 2500 — JD62B300 JD63B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — JD62B350 JD63B350
400 1250 1430 1610 1790 1960 2140 2320 2500 JXD63L400 — —
400 2000 2290 2570 2860 3140 3430 3710 4000 JXD63H400 JD62B400 JD63B400
200 1250 1430 1610 1790 1960 2140 2320 2500 — HJD62B200 HJD63B200
225 1250 1430 1610 1790 1960 2140 2320 2500 — HJD62B225 HJD63B225
HJD6(A) 250 1250 1430 1610 1790 1960 2140 2320 2500 — HJD62B250 HJD63H250
300 1250 1430 1610 1790 1960 2140 2320 2500 — HJD62B300 HJD63B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — HJD62B350 HJD63B350
400 2000 2290 2570 2860 3140 3430 3710 4000 — HJD62H400 HJD63B400
200 1250 1430 1610 1790 1960 2140 2320 2500 — HHJD62B200 HHJD63B200
225 1250 1430 1610 1790 1960 2140 2320 2500 — HHJD62B225 HHJD63B225
HHJD6 250 1250 1430 1610 1790 1960 2140 2320 2500 — HHJD62B250 HHJD63B250
300 1250 1430 1610 1790 1960 2140 2320 2500 — HHJD62B300 HHJD63B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — HHJD62B350 HHJD63B350
400 2000 2290 2570 2860 3140 3430 3710 4000 — HHJD62B400 HHJD63B400
200 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B200
225 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B225
250 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B250
CJD6 300 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — — CJD63B350
400 2000 2290 2570 2860 3140 3430 3710 4000 CJD63H400 — CJD63B400
400 1250 1450 1610 1790 1960 2140 2320 2500 CJD63L400 — —
450 2000 2290 2570 2860 3140 3430 3710 4000 — LXD62B450 LXD63B450
LXD6(A) 500 3000 3430 3860 4290 4710 5140 5570 6000 — LXD62B500 LXD63B500
600 3000 3430 3860 4290 4710 5140 5570 6000 — LXD62B600 LXD63B600
250 1250 1430 1610 1790 1960 2140 2320 2500 — LD62B250 LD63B250
300 1250 1430 1610 1790 1960 2140 2320 2500 — LD62B300 LD63B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — LD62B350 LD63B350
7

LD6(A) 400 2000 2290 2570 2860 3140 3430 3710 4000 — LD62B400 LD63B400
450 2000 2290 2570 2860 3140 3430 3710 4000 — LD62B450 LD63B450
500 3000 3430 3800 4290 4710 5140 5570 6000 — LD62B500 LD63B500
MOLDED CASE
CIRCUIT BREAKERS

600 2000 2290 2570 2860 3140 3430 3710 4000 LXD63L600 — —
600 3000 3430 3800 4290 4710 5140 5570 6000 LXD63H600 LD62B600 LD63B600
250 1250 1430 1610 1790 1960 2140 2320 2500 — HLD62B250 HLD63B250
300 1250 1430 1610 1790 1960 2140 2320 2500 — HLD62B300 HLD63B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — HLD62B350 HLD63B350
HLD6(A) 400 2000 2290 2570 2860 3140 3430 3710 4000 — HLD62B400 HLD63B400
450 2000 2290 2570 2860 3140 3430 3710 4000 — HLD62B450 HLD63B450
500 3000 3430 3860 4290 4710 5140 5570 6000 — HLD62B500 HLD63B500
600 3000 3430 3860 4290 4710 5140 5570 6000 — HLD62B600 HLD63B600
250 1250 1430 1610 1790 1960 2140 2320 2500 — HHLD62B250 HHLD63B250
300 1250 1430 1610 1790 1960 2140 2320 2500 — HHLD62B300 HHLD63B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — HHLD62B350 HHLD63B350
HHLD6 400 2000 2290 2570 2860 3140 3430 3710 4000 — HHLD62B400 HHLD63B400
450 2000 2290 2570 2860 3140 3430 3710 4000 — HHLD62B450 HHLD63B450
500 3000 3430 3860 4290 4710 5140 5570 6000 — HHLD62B500 HHLD63B500
600 3000 3430 3860 4290 4710 5140 5570 6000 — HHLD62B600 HHLD63B600
250 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B250
300 1250 1430 1610 1790 1960 2140 2320 2500 — — CJD63B300
350 2000 2290 2570 2860 3140 3430 3710 4000 — — CJD63B350
400 2000 2290 2570 2860 3140 3430 3710 4000 — — CLD63B400
CLD6
450 2000 2290 2570 2860 3140 3430 3710 4000 — — CLD63B450
500 3000 3430 3860 4290 4710 5140 5570 6000 — — CLD63B500
600 2000 2290 2570 2860 3140 3430 3710 4000 CLD63L600 — —
600 3000 3430 3860 4290 4710 5140 5570 6000 CLD63H600 — CLD63B600
500 3000 3430 3860 4290 4710 5140 5570 6000 — — LMXD63B500
600 3000 3430 3860 4290 4710 5140 5570 6000 — LMXD62B600 LMXD63B600
LMXD6 700 3200 3500 3700 4200 4700 6400 7300 8000 — LMXD62B700 LMXD63B700
800 2800 3100 3400 3700 4000 4800 5500 6000 LMXD63L800 — —
800 3200 3500 3700 4200 4700 6400 7300 8000 LMXD63A800 LMXD62B800 LMXD63B800
500 3000 3430 3860 4290 4710 5140 5570 6000 — LMD62B500 LMD63B500
600 3000 3430 3860 4290 4710 5140 5570 6000 — LMD62B600 LMD63B600
LMD6
700 3200 3500 3700 4200 4700 6400 7300 8000 — LMD62B700 LMD63B700
800 3200 3500 3700 4200 4700 6400 7300 8000 — LMD62B800 LMD63B800

7-134 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Molded Case Circuit Breakers
Adjustable Instantaneous Magnetic Trip Settings Application

Maximum Nominal ETI Motor Circuit Protector Thermal Magnetic


Breaker Continuous AC Adjustable Trip Range Catalog Number Catalog Number
Type Amperes Low 2 3 4 5 6 7 High 3-Pole 2-Pole 3-Pole
500 3000 3430 3860 4290 4710 5140 5570 6000 — — HLMXD63B500
600 3000 3430 3860 4290 4710 5140 5570 6000 — — HLMXD63B600
HLMXD6 700 3200 3500 3700 4200 4700 6400 7300 8000 — — HLMXD63B700
800 3200 3500 3700 4200 4700 6400 7300 8000 — — HLMXD63B800
500 3000 3430 3860 4290 4710 5140 5570 6000 — HLMD62B500 HLMD63B500
600 3000 3430 3860 4290 4710 5140 5570 6000 — HLMD62B600 HLMD63B600
HLMD6 700 3200 3500 3700 4200 4700 6400 7300 8000 — HLMD62B700 HLMD63B700
800 3200 3500 3700 4200 4700 6400 7300 8000 — HLMD62B800 HLMD63B800
500 3000 3430 3860 4290 4710 5140 5570 6000 — MD62B500 MD63B500
600 3000 3430 3860 4290 4710 5140 5570 6000 — MD62B600 MD63B600
700 4000 4570 5140 5710 6280 6850 7420 8000 — MD62B700 MD63B700
MD6 800 3000 3430 3860 4280 4710 5140 5570 6000 MXD63L800 — —
800 4000 4570 5140 5710 6280 6850 7420 8000 MXD63A800 MD62B800 MD63B800
800 5000 5715 6430 7145 7860 8575 9290 10000 MXD63H800 — —
500 3000 3430 3860 4280 4710 5140 5570 6000 — MXD62B500 MXD63B500
600 3000 3430 3860 4280 4710 5140 5570 6000 — MXD62B600 MXD63B600
700 4000 4570 5140 5710 6280 6850 7420 8000 — MXD62B700 MXD63B700
MXD6 800 3000 3430 3860 4280 4710 5140 5570 6000 MXD63L800 — —
800 4000 4570 5140 5710 6280 6850 7420 8000 MXD63A800 MXD62B800 MXD63B800
800 5000 5715 6430 7145 7860 8575 9290 10000 MXD63H800 — —
500 3000 3430 3860 4280 4710 5140 5570 6000 — HMD62B500 HMD63B500
600 3000 3430 3860 4280 4710 5140 5570 6000 — HMD62B500 HMD63B600
HMD6 700 4000 4570 5140 5710 6280 6850 7420 8000 — HMD62B700 HMD63B700
800 4000 4570 5140 5710 6280 6850 7420 8000 — HMD62B800 HMD63B800
500 3000 3430 3860 4280 4710 5140 5570 6000 — — HMXD63B500
600 3000 3430 3860 4280 4710 5140 5570 6000 — — HMXD63B600
HMXD6 700 4000 4570 5140 5710 6280 6850 7420 8000 — — HMXD63B700
800 4000 4570 5140 5710 6280 6850 7420 8000 — — HMXD63B800
400 3000 3430 3860 4280 4710 5140 5570 6000 — —
500 3000 3430 3860 4280 4710 5140 5570 6000 — —
600 3000 3430 3860 4280 4710 5140 5570 6000 — — CMD63B600
CMD6 700 4000 4570 5140 5710 6280 6850 7420 8000 — — CMD63B700
800 3000 3430 3860 4280 4710 5140 5570 6000 CMD63L800 — —
800 4000 4570 5140 5710 6280 6850 7420 8000 CMD63A800 — CMD63B800
800 5000 5715 6430 7145 7860 8575 9290 10000 CMD63H800 — —
800 4000 4570 5140 5710 6280 6850 7420 8000 — ND62B800 ND63B800
900 5000 5715 6430 7145 7860 8575 9290 10000 — ND62B900 ND63B900
ND6 1000 5000 5715 6430 7145 7860 8575 9290 10000 — ND62B100 ND63B100
1200 5000 5715 6430 7145 7860 8575 9290 10000 — ND62B120 ND63B120
900 5000 5715 6430 7145 7860 8575 9290 10000 — NXD62B900 NXD63B900
NXD6 1000 5000 5715 6430 7145 7860 8575 9290 10000 — NXD62B100 NXD63B100
1200 5000 5715 6430 7145 7860 8575 9290 10000 — NXD62B120 NXD63B120
800 4000 4570 5140 5710 6280 6850 7420 8000 — HND62B800 HND63B800
900 5000 5715 6430 7145 7860 8575 9290 10000 — HND62B900 HND63B900

7
HND6 1000 5000 5715 6430 7145 7860 8575 9290 10000 — HND62B100 HND63B100
1200 5000 5715 6430 7145 7860 8575 9290 10000 — HND62B120 HND63B120

CIRCUIT BREAKERS
MOLDED CASE
900 5000 5715 6430 7145 7860 8575 9290 10000 — — HNXD63B900
HNXD6 1000 5000 5715 6430 7145 7860 8575 9290 10000 — — HNXD63B100
1200 5000 5715 6430 7145 7860 8575 9290 10000 — — HNXD63B120
800 4000 4570 5140 5710 6280 6850 7420 8000 — — CND63B800
900 5000 5715 6430 7145 7860 8575 9290 10000 — — CND63B900
CND6 1000 5000 5715 6430 7145 7860 8575 9290 10000 — — CND63B100
1200 5000 5715 6430 7145 7860 8575 9290 10000 — — CND63B120
1200 5000 5715 6430 7145 7860 8575 9290 10000 — — PD63B120
PD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — PD63B140
1600 5000 5715 6430 7145 7860 8575 9290 10000 — — PD63B160
1200 5000 5715 6430 7145 7860 8575 9290 10000 — — PXD63B120
PXD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — PXD63B140
1600 5000 5715 6430 7145 7860 8575 9290 10000 — — PXD63B160
1200 5000 5715 6430 7145 7860 8575 9290 10000 — — HPD63B120
HPD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — HPD63B140
1600 5000 5715 6430 7145 7860 8575 9290 10000 — — HPD63B160
1200 5000 5715 6430 7145 7860 8575 9290 10000 — — HPXD63B120
HPXD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — HPXD63B140
1600 5000 5715 6430 7145 7860 8575 9290 10000 — — HPXD63B160
1200 5000 5715 6430 7145 7860 8575 9290 10000 — — CPD63B120
CPD6 1400 5000 5715 6430 7145 7860 8575 9290 10000 — — CPD63B140
1600 5000 5715 6430 7145 7860 8575 9290 10000 — — CPD63B160
1800 5000 5715 6430 7145 7860 8575 9290 10000 — — RD63B180
RD6 2000 5000 5715 6430 7145 7860 8575 9290 10000 — — RD63B200
1800 5000 5715 6430 7145 7860 8575 9290 10000 — — RXD63B180
RXD6 2000 5000 5715 6430 7145 7860 8575 9290 10000 — — RXD63B200
1800 5000 5715 6430 7145 7860 8575 9290 10000 — — HRD63B180
HRD6 2000 5000 5715 6430 7145 7860 8575 9290 10000 — — HRD63B200
1800 5000 5715 6430 7145 7860 8575 9290 10000 — — HRXD63B180
HRXD6 2000 5000 5715 6430 7145 7860 8575 9290 10000 — — HRXD63B200

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-135


Revised on 02/28/19

Molded Case Circuit Breakers


Molded Case Switch — Circuit Disconnect Selection

2-Pole 3-Pole
Maximum Self-Protective Ordering Information
Frame Instantaneous
Amp Rating Catalog Number Catalog Number Override±20%c Order by catalog number. Switches
BQ2S060 n BQ3S060n 11000 include frame and self protective trip
1100 unit only. Order lugs separately from
BQ2S100n BQ3S100n 11000
1125 ED22S100An ED23S100A 11000 pages 7-143 to 7-145.
ED42S100An ED43S100A 11000
ED42S125An ED43S125A 11000
ED62S100An ED63S100A 11000
— ED63S125A 11000
CED62S100An CED63S100An 11000
CED62S125An CED63S125An 11000
1250 — HQR23S250HA 12000
FXD62S250A FXD63S250A 13200
HFXD62S250An HFXD63S250An 13200
a CFD63S250An 13200
1400 JXD22S400An JXD23S400A 16000
— JXD63S400A 16000
— HJXD63S400An 16000
a
CJD63S400An 16000
1600 — LXD63S600A 16000
— HLXD63S600An 16000
a
CLD63S600An 16000
1800 — LMXD63S800An 18000
— MXD63S800A 18000
a
CMD63S800A 18000
1200 — NXD63S120A 10000
a
CND63S120An 10000
1600 a
PXD63S160Ae 10000
2000 a
RXD63S200Ane 10000
7 MOLDED CASE
CIRCUIT BREAKERS

n Built to order. Allow 2–3 weeks for delivery. c Molded


 case switches up to R frame contain a self
a For protecting instantaneous element, which may open Lugs pages 7-143 to 7-145
 2-pole application use outside poles of 3-pole circuit
breaker.
circuit above their override set point. Enclosures Section 6
d UL file E57556 Volume 1, section 2 and
b For
 additional lugs see pages 7-143 to 7-145.

Accessories pages 7-150 to 7-155
CSA LR 42022-51.
e Requires mounting block MB9301 or MBR9302.

7-136 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 05/31/18

Molded Case Circuit Breakers


Digital Solid State Sentron Sensitrip IV Series Technical

The Sentron Sensitrip IV Functions available in Sentron Sensitrip circuit breakers


circuit breaker is a true RMS Short Short
current sensing device. Digital Catalog Cont Long Instan- Short Time Time Ground Ground
microprocessor circuitry within the Number Trip Current Time taneous Time Fixed I2t Fault Fault
Suffix Type Setting Delay Pickup Pickup Delay Delay Pickup Delay
electronic trip unit provides more
precise control over the circuit LI LI u u u
breaker functions. This control LIG LIG u u u u u
allows circuit coordination flexibility LSI LSI u u u u u u
not available with thermal magnetic
LSIG LSIG u u u u u u u u
circuit breakers.

Typical Trip Unit Labeling and Adjustment Positions for the Sentron Sensitrip Circuit Breaker.

LI Trip Unitsa

LIG Trip Unitsa

LSI Trip Unitsa

7
CIRCUIT BREAKERS
MOLDED CASE
LSIG Trip Unitsa

ln = Maximum circuit breaker ampere rating Ig = Ground fault pickup expressed in amperes
lr = Continuous current rating expressed in amperes tsd = Short time delay - either fixed or I2t time delay function
Ii = Instantaneous pickup expressed in amperes tld = Long time delay - I2t time delay function
Isd = Short time pickup expressed in multiples of Ir tg = Ground fault delay - I2t time delay function

NOTE: Frame rating (In) of 600A shown as an example. a Schematic of advanced trip unit shown. Basic trip units
Trip unit settings will vary based on the specific frame are identical but do not include DAS / Maintenance
rating (In) of the device. Mode functionality.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-137


Revised on 05/31/18

Molded Case Circuit Breakers


Digital Solid State Sentron Sensitrip IV Series Technical

A. Adjustable “Continuous Amps”


Rating Switch D. Adjustable “Short Time
All Sensitrip IV solid state molded Pick-Up” Switch (Optional)
(Ir) case circuit breakers have an adjustable (Ir) Sensitrip IV circuit breakers with
ampere rating switch. Adjustments an adjustable short time pick-up
made to this switch change the switch allow for selection of short
continuous current rating of the breaker. Time time pick-up in a range from 1.5
B. Adjustable “Long Time to 10 times the setting of the
(tld) 6 x Ir maximum current rating.
Delay” Switch (tld)
All Sensitrip IV circuit breakers have E. Adjustable “Short Time
an adjustable long time delay switch to Delay” Switch (Optional)
allow for selection of long time delays Sensitrip IV circuit breakers with
of fixed time intervals at six times the an adjustable short time pick-up
setting of the adjustable “continuous switch also contain a switch for
amps” rating switch. Time adjustment in time delay. The
C. Adjustable “Instantaneous adjustable short time delay switch
Pick-Up” Switch allows for either of two modes of
( Ii ) (Isd) short time delays. One range of
Sensitrip IV circuit breakers with an settings enables the breaker to be
adjustable instantaneous pick up set for fixed time delays and the
switch allow selection of a specific other range of settings enables
instantaneous trip setting. Time the breaker to be set for short time
delays based on l2t curves.

(tsd)

ln = Maximum circuit breaker ampere rating


Adjustable “Ground Fault Pick-Up” Switch
lr = Continuous current rating expressed in amperes
 ensitrip IV circuit breakers containing the
S
optional equipment ground fault protection Ii = Instantaneous pickup expressed in amperes
have a ground fault pick-up setting. The
ground fault pick-up settings allow for one Isd = Short time pickup expressed in multiples of Ir
of three time delays based on I2t curves.
For 3-phase, 4-wire systems, an external Ig = Ground fault pickup expressed in amperes
neutral transformer is required with an
ampere rating equal to the trip unit ampere
tsd = Short time delay - either fixed or I2t time delay
3 x Ig
(tg) rating. function
(Ig)
tld = Long time delay - I2t time delay function
tg = Ground fault delay - I2t time delay function

Examples of Adjustment Settings


Catalog Number SLD6A600LI
7

Switch 1 Swtich 2 Switch 3


Frame
MOLDED CASE
CIRCUIT BREAKERS

Rating (In) Continuous Current Setting (Ir) Long Time Delay Setting (tld) Instantaneous Pickup Setting (Ii)
Setting 600A 200 2.5 750
Description 600A max current rating 200A 2.5 sec to trip @ 6 x Ir [6 x 200A = 1200A] 750A

Catalog Number SLD6A600LSIG


Switch 1 Switch 2 Swtich 3 Switch 4
Frame Short Ground Fault Ground Fault
Rating Cont. Current Long Time Short Time Instantaneous Time Delay Pickup Setting Delay Setting
(In) Setting (Ir) Delay Setting (tld) Pickup Setting (Isd) Pickup Setting (Ii) Setting (tsd) (Ig) (tg)
Setting 600A 300 10 1.5 5 0.1 36 [.18] 36 [.18]
600A max 10 sec @ 6 x Ir 1.5 x Ir 5 x In Ig = 36 x 10 0.18 sec @ 3 x Ig
Description 300A 0.1 sec
current rating [6 x 300A = 1800A] [1.5 x 200A = 300A] [5 x 600A = 3,000A] [36 x 10 = 360A] [3 x 360 = 1,080A]

7-138 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


WL Power Circuit Breakers
3-pole & 4-pole, up to 6000A General

Breaker Description
The ever-increasing use of plant and Trip Units
energy management systems has The electronic, micro processor-based b Manual operating mechanism with
intensified the demand for circuit trip unit is auxiliary voltage-independent mechanical and electrically
breakers supporting multiple open for all protective functions and enables interlocked closing
protocols to monitor and control the flow adaptation to the different protection
of energy in the power system. The b Motorized operating mechanism with
requirements of distribution systems, mechanical and electrically interlocked
extensive and modular WL family of motors, transformers and generators. closing. Operating mechanisms with
circuit breakers and accessories provides electrically interlocked closing are
this for applications from 200A to 6000A. Non-Automatic Switch
suitable for synchronizing tasks
Applications A special version of the circuit breaker is
used as a non-automatic switch. Auxiliary Contacts
WL breakers can be applied as main, tie,
The non-automatic switch is constructed Auxiliary switches can be added accord-
feeder or distribution breakers in
without a trip unit and has no protective ing to the type of installation. They are
low-voltage electrical power systems.
function. A possible application is for use easily mounted via front, top mounted
Versions as a tie in systems with parallel feeds. terminal blocks.
b Frame ratings: 800A to 6000A Main Bus Connectors Modularity
b 3 physical frame sizes Breakers are equipped with standard Common guide frames for the draw-out
b Rated nominal operating voltage up vertical main bus connections. Horizontal version make them completely inter-
to 635VAC bus connections are available as an changeable between the UL 489 and
b Seven interrupting classes from 50kA option in Frame Size 1 and 2 up to ANSI / UL 1066 rated circuit breakers.
to 200kA at 480V 2000A. Components, such as auxiliary releases,
b Circuit breaker or non-automatic switch Communication Capability motorized operating mechanisms, trip
units, current sensors, auxiliary
b WL Circuit Breakers are delivered as MODBUS or PROFIBUS communica-
signal switches, automatic reset devices
complete assembled breakers or tions transmit the acquired and metered
or interlocks can be used to modify or
individual frames, guide frames, and data, such as current values, breaker
accessories retrofit any circuit breaker to meet
status, trip log, etc. to a central
changing requirements. The main con-
Installation Types monitoring computer. With a factory
tacts can be replaced to extend the life
installed metering function option, the
Fixed-mounted or Draw-out version. of the circuit breaker and feature inte-
WL acquires data useful for power
grated contact wear indicators.
Standards management and can contribute to a
significant savings in energy costs. A Electronic Trip Unit Modularity
b WL ANSI / UL 1066 Circuit Breakers
will satisfy: C37.13, C37.16, C37.17, new, internal circuit breaker bus enables Modularity is the outstanding feature of
C37.50, NEMA SG3 the expansion of breaker functionality the new WL Circuit Breakers. The trip
through the integration of many

7
units themselves can be retrofitted with
b WL UL 489 Circuit Breakers will secondary functions which were
satisfy: UL 489 special LCDs, ground fault modules,
previously separate, including: rating plugs and communication

CIRCUIT BREAKERS
MOLDED CASE
b WL Circuit Breakers are suitable for
use in UL 1558 LV Switchgear and UL b Control of analog displays modules.100% Rated Circuit Breaker WL
circuit breakers are designed for
891 LV Switchboards b Options for testing the
communication setup continuous operation at 100% of their
Conditions of Application current rating without the need for
WL Circuit Breakers are designed to b Display of breaker status and reason external heat sinks.
for trip
meet standard Industrial and Commercial
Conditions of Application
application requirements. b Input modules for reading other
external signals and transmitting WL Circuit Breakers are designed to
Uniform Dimensions these signalsvia PROFIBUS or meet standard Industrial and Commercial
WL Circuit Breaker dimensions differ MODBUS communication application requirements.
only in the device width, which varies by
b A selection of output modules to
frame size. With the exception of the provide contact closures based on
200kA ANSI Frame Size II which has an events or measured-value setpoints.
additional 5” in depth to accommodate It is not only possible to monitor the
integral fuses and the UL489 Frame Size breaker remotely, it is also possible
I which measures only 15” in height to to open and close the breaker as well
allow six-high stacking in switchboards. as setting parameters remotely
Minimal Space Requirements Operating Mechanisms
The WL design is extremely compact Circuit breakers can be optionally
without sacrificing performance and does delivered with different operating
not use energy-wasting heat sinks. mechanisms, including:
b Manual operating mechanism with
mechanical closing (standard)

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-139


WL Power Circuit Breakers
Communication Information General
7 MOLDED CASE
CIRCUIT BREAKERS

7-140 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


WL Power Circuit Breakers
Electronic Trip Units General

Trip Unit Functions


Basic Protective Functions ETU745 ETU748 ETU776
Long-time overcurrent protection L l l l

Short-time delayed overcurrent protection S l l l


Instantaneous overcurrent protection I l l l
Neutral conductor protection N l l l
Ground fault protection G u u u

Additional Functions
Selectable neutral protection l l l
Defeatable short-time protection l — l
Defeatable instantaneous protection l — l
Selectable thermal memory l l l
Zone selective interlocking l l l
Selectable I2t or fixed short-time delay l l l
Adjustable instantaneous pick-up l — l
Selectable I2t or I4t long-time delay l l l
Adjustable short-time delay and pick-up l l l
Selectable and adjustable neutral protection l l l
Dual protective setting capability — — l

7
Dynamic arc-flash sentry — — l
Extended instantaneous protection l l l

CIRCUIT BREAKERS
MOLDED CASE
Parameterization and Displays
Parameterization by rotary switches (10 steps) l l —
Parameterization by communication (absolute values) — l l
Parameterization by menu/keypad (absolute values) — — l
Remote parameterization of the basic functions — — l
Remote parameterization of the additional functions — — l
Alphanumeric LCD u u —
Graphical LCD — — l

Metering Function
Metering function u u u

Metering function Plus u u u

Communication
CubicleBUS l l l
Communication via PROFIBUS-DP u u u

Communication via the MODBUS u u u

Communication via the Ethernet (BDA) u u u

l Standard — Not available u Optional

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-141


WL Power Circuit Breakers
3-pole & 4-pole, up to 6000A General

Rating Plug a wide range of locking devices can be b Spring charge indicator
It is no longer necessary to replace the installed or retrofit, including: Rear vertical main contacts
b
current transformer to change the rated b Lockable drawout version to protect
current of the breaker. Instead, you b Main contact replacement flag
against unauthorized removal
simply replace the rating plug which is (standard) b Auxiliary plug system with bare wire
easily accessible on the front of the trip pressure screw terminals. Delivery
unit. The circuit breaker is set to the new b High degree of protection through includes all auxiliary plugs necessary
rated current quickly and is already Plexiglas cover
correctly labeled. for both factory installed and future
Long Time Overcurrent Protection b Mechanical reclosing lockout after field installed accessories
with Switchable I2t/I4t Characteristics long-time, short-time or instantaneous Mechanical trip indicator of the
trip (optional) b
The long time overcurrent overcurrent release system
protection in the ETU745, ETU755 and b Devices with trip unit ETU745 or b Automatic reset after trip
ETU776 trip units can be switched higher are equipped with temperature
between an I2t and I4t characteristic to sensors on the BSS and b The front panel cannot be removed if
improve coordination between upstream COM15/COM16 (standard) the circuit breaker closed
circuit breakers and fuses. Laminated main contact fingers as part
Front Panel b Lock provision for locking the breaker b
in the OPEN position of the breaker contact strip on
The front panel is designed so that it can the drawout circuit breaker
be accessed through a cutout in the b Lockable covers for the CLOSE button
door, which means that all controls and b Breaker position display in the
displays are accessible even when the b Lockable racking handle prevents operator’s panel
moving the breaker
cubicle door is closed. The front panels Captive crank handle for racking out
b
of all Frame Size II and Frame Size III b Lockable charging handle prevents the breaker
circuit breakers are identical, and allow charging the springs
for two different through-door access Standard Version Features b Guide frame with guide rails for easy
designs: Trip unit and front panel controls handling of draw-out version
or front panel controls only. The degree WL Circuit Breakers have the following
of protection of the front panel is IP 20. standard equipment: b Breaker cannot be moved in the
Environmental Protection CLOSED state
b Mechanical CLOSE and mechanical
The plastics used are halogen-free and OPEN push buttons b Rated current coding between the
recyclable. guide frame and the breaker
b Manual operating mechanism with
Safety and Reliability mechanical closing b Suitable for reverse feed applications
In order to help protect the electrical The breaker is always equipped with
distribution system and circuit breaker b Contact position indicator b
the required number of secondary
against unauthorized breaker operations, b Front panel ready-to-close indicator disconnect blocks
Exclusive Features
Generator/Utility Dynamic Arc-Flash Sentry (DAS) employs the instantaneous function is switched
7

Protection Sets the unique dual protective setting capa- off on an ‘LSI’ trip unit, can only be
24/7/365 power availability is critical for bility of the 776 trip unit, coupled with applied up to it’s short-time rating,
the ability to easily toggle to a lower arc commonly 85kA or less. For application
MOLDED CASE
CIRCUIT BREAKERS

some systems. On-site generation capa-


bility is growing more and more common flash parameter set. A normal operation on systems with levels of available fault
in many systems. All of the WL digital parameter set can be optimized for current above the short-time rating, the
electronic trip units allow the system selective trip coordination, while the typical ‘LS’ power circuit breaker cannot
designer to precisely tailor trip settings second set is optimized for lower arc be applied or must employ an instanta-
for the most demanding requirements. flash energy levels. The dynamic action neous override. This instantaneous
However, the 776 trip unit allows one set comes from the ability to switch from override is set at as much as 20% below
of trip settings for a fully loaded utility the normal operation set to the arc flash the short-time rating and can seriously
feed and with a simple contact closure, limiting set based on the presence of compromise selective trip coordination
the trip unit toggles to a second trip set personnel as they approach the flash with downstream breakers.
tailored to provide optimal generator pro- protection boundary. A wide variety of The WL, equipped with EIP, overcomes
tection. The wide range of settings switching methods may be used based these limitations by providing full
allows the WL to provide protection for on the needs of a particular facility. The withstand capability, and full coordina-
a minimal generator capacity for only capabilities range from fully automatic tion, with a minus 0% short-time band
essential loads, through full backup for an switching using appropriate occupancy tolerance up to 85kA on frame Size II
entire facility. This dual utility/generator sensors to manual switching via a and 100kA on Size III. Above fault cur-
protection capability in a single circuit key operation. rents of 20% higher than the full short-
breaker allows the system designer Extended Instantaneous Protection time rating, the WL breaker is self-pro-
unparalleled, cost effective, flexibility. Extended Instantaneous protection (EIP), tecting, and the EIP function will trip the
Dynamic Arc-Flash Sentry another unique feature of the WL trip breaker instantly to protect the frame
unit, allows the system designer to and the system from these extremely
A unique feature of the WL trip unit high currents, as high as 150kA on frame
allows the system designer to achieve achieve full selective trip coordination up
to the short-time rating of the frame Size III. One added benefit is that arc
lower levels of arc flash energy and flash energy is greatly reduced in this
delayed tripping for selective trip while also allowing application of the
breaker up to the interrupting rating of high current region due to the instanta-
coordination purposes. neous trip response that EIP provides.
the frame. The typical power circuit
breaker with an ‘LS’ trip unit, or when

7-142 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 06/30/19

Lug Information
Mechanical Lug Selection

For Use Circuit Breaker Cables Per Catalog


With Type(s) Ampere Rating Lug Lug Wire Range Number
Line Side
1 #14–#6 AWG Cu
15–40 TC1Q1 ab
1 #12–#6 AWG Al
1 #8–#1 AWG Cu
45–125 TA1Q1 b
BQ, BQH, 1 #6–#1/0 AWG Al
BQHF Load Side
BQE,
1 #14–#10 AWG Cu Lugs are integral to
BQF, 15–20
1 #12–#10 AWG Al Circuit Breaker
BL, BLH,
HBL, 1 #14–#6 AWG Cu Lugs are integral to
25–35
HBQ 1 #12–#6 AWG Al Circuit Breaker
Switching 1 #8–#6 AWG Cu Lugs are integral to
Neutrals 40–50
1 #8–#4 AWG Al Circuit Breaker
BG,
55–70 1 #8–#4 AWG Cu Lugs are integral to
BLG
*exceptions in Table A 1 #8–#2 AWG Al Circuit Breaker
1 #4–#1/0 AWG Cu Lugs are integral to
80–100
1 #2–#1/0 AWG Al Circuit Breaker
1 #2–#1/0 AWG Cu Lugs are integral to
110–125
1 #1/0–#2/0 AWG Al Circuit Breaker
Line Side (CQD, CQD6) & Load Side
BQD, CQD #14–#6 AWG Cu
15–40 1 Integral
BQD6, CQD6 #12–#6 AWG Al
#8–#1 AWG Cu
45–100 1 Integral
#6–#1/0 AWG Al
#14–#6 AWG Cu
15–30 1 TC1Q1
#12–#6 AWG Al
#14–#6 AWG Cu
NGG, HGG, 15–30 1 3TC1Q1 (pkg. of 3)
#12–#6 AWG Al
LGG
#8–#1/0 AWG Cu
35–125 1 3TC1GG20 (pkg. of 3)
#8–#2/0 AWG Al
c
15–125 — NUT KEEPER PLATE TNKG3 (pkg. of 3)
Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards.

Table A

7
For Use Circuit Breaker
With Type(s) Ampere Rating Cables Per Lug Lug Wire Range Number of Poles
Load Side

CIRCUIT BREAKERS
MOLDED CASE
#8–#4 AWG Cu-Al
This exception is applicable
BQ, BL, QP 55-60 1 #3 AWG requires 22 or 65
to 1- and 2-pole only
kAIC

Note:
(A) Molded case circuit breakers having a rated ampacity a Lug
 is steel.
of 125 amperes or less are to be connected with 60 or b Sold
 in package of six.
75°C wire. Circuit breakers having a rated ampacity c One
 nut keeper plate is required with each lug on the
greater than 125 amperes shall only be cabled with NGG breaker.
75°C cable unless otherwise indicated on the circuit
breaker label. Exceptions to this rule are outlined in
article 110-14 C(1)(2) of the 2005 National
Electrical Code.
(B) Connector wire ranges and cavities are established in
conjunction with Table 6.1.4.2.1 of UL 489 standards.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-143
Revised on 05/31/18

Lug Information
Aluminum Body Lugs for Copper or Aluminum Wire Selection

For Use Circuit Breaker Cables Per Catalog


With Type(s) Ampere Rating Lug Lug Wire Range Number
QR2, QR2H, 3TA1QR300
100-250 1 #3–300 Kcmil Al/C
HQR2, HQR2H (3 lugs per kit)
#14–#10 AWG (Cu)
All 2, 3-pole 15–25 1 SA1E025
#12–#10 AWG (Al)
ED2, ED4, ED6,
ED6 ETI, 30–100 1 #10–#1/0 (Cu or Al) LN1E100
HED4,
HHED6 #3-3/0 (Cu)
110–125 1 TA1E6125
#1-2/0 (Al)
LD1E060
CED6 30–60 1 #10–4 (Cu or Al)
(Load Side)
All 1-pole
ED, HED LD1E100
70–100 1 #4–#1/0 (Cu or Al)
(Load Side)
FXD6-A, FD6-A,
HFD6, #6 AWG–350 kcmil (Cu)
70–250 1 TA1FD350A
cfd6 #4 AWG–350 kcmil (Al)
HHFD6
SJD6-B,
SHJD6-B 65-200 1–2 #4 AWG–3/0 (Cu or Al) TA2J630
SCJD6-B
JXD2(A), JXD6(A),
JD6(A), SJD6-B,
HJD6(A), HJXD6(A) 3/0–500 kcmil (Cu)
200–400 1–2 TA2J6500
HHJXD6, HHJD6, 4/0–500 kcmil (Al)
SHJD6-B, CJD6,
SCJD6-B
LXD6(A), LD6(A),
SLD6-B, HLD6(A),
3/0–500 kcmil (Cu)
HLXD6(A), HHLXD6, 250–600 1–2 TA2J6500
4/0–500 kcmil (Al)
HHLD6, SHLD6-B,
CLD6, SCLD6-B
LMD6a, LMXD6a,
1–2 #1–500 kcmil (Cu or Al) TA2K500
HLMD6a,
HLMXD6a, MD6, 500–600
MXD6, SMD6-B, 1–3 1/0–500 kcmil (Cu or Al) TA3K500
HMD6, HMXD6,
SHMD6-B, CMD6,
SCMD6-B 500–800 1–2 500–750 kcmil (Cu or Al) TA2N750 b
7

ND6, 2TA4P8500 bc
NXD6, SND6-B, 250–500 kcmil (Cu or Al)
3TA4P8500 bd
HND6, HNXD6, 800–1200 1–4
MOLDED CASE
CIRCUIT BREAKERS

SHND6-B, CND6, 2TA4N8500 c


250–500 kcmil (Cu or Al)
SCND6-B 3TA4N8500 d
PD6, HPD6,
CPD6
PXD6,
1200–1600 1–5 300–600 kcmil (Cu or Al) TA5P600
HPXD6,
SPD6-B,
SHPD6-B
PD6, PXD6,
HPD6, HPXD6,
SPD6-B, SHPD6-B, 1200–2000 1–6 300–600 kcmil (Cu or Al) TA6R600
RD6, RXD6,
HRD6, HRXD6, STD

a Use
TA2K500 or TA3K500 only. c Contains 2 connectors plus 1 NDTS end barrier.
b Used
for 100% rated MD/ND frame breakers. d Contains 3 connectors plus 1 NDTS end barrier.
Rated for 90° C cable.

7-144 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 11/30/19

Lug information
Optional Mechanical Lugs Selection

For Use Circuit Breaker Cables Lug Qty Per


With Type Ampere Rating Per Lug Material Lug Wire Range Catalog No Catalog Number
QR2, QR2H, 3TC1QR2520
100-250 1 Cu #3 - 300 Kcmil Cu ONLY) 3
HQR2, HQR2H (3 lugs per kit)
ED, HED 1, 2 & 3-pole 1, 2 & 3-pole 30-125 1 Cu #10–#1/0 (Cu) 1 TC1ED6150
HFD6, HHFD6,
70–250 1 Cu #6 AWG–350 kcmil (Cu) 1 TC1FD350
CFD6, F(X)D6-A
J(X)D2(A), J(X)D6(A), 1 3/0–600 kcmil (Cu) 1 TC1J6600a
200–600 Cu
HJD6(A), HHJD6, 1–2 3/0–500 kcmil (Cu) 1 TC2J6500a
SHJD6-B, L(X)D6(A),
HHLD6, SCD6-B,
HLD6(A), SHLD6-B, 1 500–750 kcmil (Al)
250–600 Al 1 TA1L6750
CJD6, CLD6, SCJD6-B, 1 500–600 kcmil (Cu)
SCLD6-B

SMD6-B, M(X)D6, 500–600 1–2 Cu #1 AWG–500 kcmil (Cu) 1 TC2K500


HM(X)D6, HMD6, 500–750 kcmil (Cu) 2 2TA2N8750
CMD6, SCMD6-B, SND6-B, 700–800 1–2 Al
500–750 kcmil (Al) 3 3TA2N8750
N(X)D6, HN(X)D6,
SHND6-B, CND6, SCND6-B 500–750 kcmil (Cu) 2 2TA3N8750
800–1200 1–3 Al
500–750 kcmil (Al) 3 3TA3N8750
R(X)D6, HR(X)D6 1600–2000 1–5 Cu 300–600 kcmil (Cu) 1 TC5R600
P(X)D6, HP(X)D6,
1200–1600 1–4 Al 600–750 kcmil (Cu/Al) 1 TA4P750s
CPD6, SPD6-B, SHPD6-B

Compression Lugs
Ampere Lugs
For Circuit Breaker Types Rating Poles Per Kit Lug Wire Size Catalog Number
Lugs (contains indicated number of lugs and necessary hardware per kit)
ED2, ED4, ED6, HED4, HHED6, CED6 15–125 1, 2, 3 1 #2/0 AWG Cu/Al CCE125
QR2, QR2H, HQR2, HQR2H 100-250 2-3 1 #6 - 350kcmil Al/Cu CCQ250
F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 125–250 2, 3 1 350 kcmil CCF250
JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6, SJD6-B, SHJD6-B,
200–600 2, 3 1 500 kcmil CCL600
SCJD6-B, L(X)D6-A, HL(X)D6-A, CLD6, SLD6-B, SHLD6-B, SCLD6-B
Kits (contain lugs and hardware for complete line or load end of 2 or 3-pole breaker)
2 6 CCM800K2
M(X)D6, HM(X)D6, CMD6, SMD6-B, SHMD6-B, SCMD6-B 500–800
3 9 CCM800K3
500 kcmil
2 8 CCN1200K2

7
N(X)D6, HN(X)D6, CND6, SND6-B, SHND6-B, SCND6-B 900–1200
3 12 CCN1200K3

CIRCUIT BREAKERS
MOLDED CASE
Distribution Lugs
Ampere Lugs Wires
For Circuit Breaker Types Rating Poles Per kit Per Lug Lug Wire Size Catalog Number
#6-#4 AL
NGG, HGG, LGG 15-125 1,2,3 1 6 TA6GG04
#14-#4 Cu
#14-#4 AWG Cu
ED2, ED4, ED6, HED4, HHED6, CED6 15-125 1,2,3 1 6 TA6ED06
#6-#4 AWG Al
#14-#4 AWG Cu
F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 70-250 2,3 1 6 TA6FD04
#6-#4 AWG Al

JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6-A,


#14-2/0 AWG Cu
SJD6-B, SHJD6-B, SCJD6-B, L(X)D6-A, HL(X)D6-A, CLD6-A, 200-600 2,3 1 6 TA6JD20
#6-2/0 AWG Al
SLD6-B, SHLD6-B, SCLD6-B

s Built to order. Allow 6–8 weeks for delivery. a Used for 100% rated JD/LD frame circuit breakers.
 Special purpose wire connectors, not for general use.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-145
Revised on 10/31/18

Molded Case Circuit Breakers


Modifications General/Selection

A variety of internal and external 50°C Ambient Calibration — Not UL listed and not available for solid state, 100% rated breakers
accessories, as well as modifications, or 400HZ calibrated breakers.
are available to adapt Siemens circuit  or BL Type Circuit Breakers
F
breakers to special installation    — Add suffix ‘M’ to catalog number
(Example: B120M).....................................................................................No Charge
requirements. UL listed internal
accessories for 100 through 2000A For BQ and ED Frame Circuit Breakers
   — Replace ‘B’ in catalog number with ‘M’..................................................No Charge
circuit breakers are field-addable. (Example: BQ3M060, ED63M060)
Internal accessories fine tune an For FD, JD, LD, LMD, MD, ND, PD, and RD Frame Circuit Breakers
electrical distribution system, Non-Interchangeable Trip (3–pole only).................................................No Charge
allowing control of the circuit breakers to    — Replace ‘B’ in catalog number with ‘M’
(Example: FXD63M225, JXD63M400)
meet special application requirements.
400 HZ Calibration
For example, emergency situations may
dictate tripping critically placed circuit UL Listed (5KA IR)
breakers quickly. Shunt trips accomplish for BQ & BL Type Circuit Breakers (200A max.)............................................Add 25% to list price
   — Add suffix ‘Y’ to catalog number
this conveniently and efficiently.
Or, when voltage drops are a concern, Not UL Listed
for all other Circuit Breakers, see derating tables on page 7-157 and order standard circuit breakers.
undervoltage trips automatically open
Fungus Proofing
the circuit breaker at a predetermined
voltage level. All BQD, CQD, GB, GG, ED, FD, JD, LD, LMD, MD, ND, PD, RD, DG, FG, JG, LG, MG, NG, and PG
Frame Circuit Breakers are inherently fungus resistant and do not require special treatment.
A wide range of external operating and For BL, and BQ Type Circuit Breakers.............................................................Add $10.00 net per pole
mounting accessories is also available.    — Consult Sales Office for Availability
For example, face, shallow, and back For all other Circuit Breaker Types..................................................................Add $160.00 net per device
mounting plates are ideal for tailoring BQ    — Consult Sales Office for Availability
circuit breakers to OEM applications. Certificate of Compliance with Test Report (catalog number CERT OF COMP.) Add $210.00 net
A complete line of operating handles Certificate of compliance testing must be performed on the actual device being shipped.
and handle-blocking devices meet The certificate cannot be provided after initial shipment. Order for devices with COC requirement
must be placed directly with the factory by the sales office and shipped directly to the end user.
switchboard, enclosure and safety
needs. Plug-in mounting assemblies,
which simplify switchboard mounting of
circuit breakers and permit breaker
removal without disconnecting bus or
cable connections, are available.

UL 489 Supplement SB Naval Use Breakers Ordering Information


Breakers tested to UL 489 Supplement SB are qualified for use For “NAVAL” label, add $75. net per catalog number per order.
7

on non combat and auxiliary naval vessels.


Order must be placed directly with the factory by Siemens
Various Siemens molded case breakers can be labeled "NAVAL" Sales Office.
MOLDED CASE
CIRCUIT BREAKERS

in compliance with UL 489 Supplement SB. See table to the


right for specific breaker types and UL file references.
Supplement SB testing comprises two sets of vibration tests. Breaker Type UL File
The first is to find mechanical resonances in the product and BL E82615, Vol 1, Sec 1 & 4
to subject the breaker to extreme testing at each resonant NGB E10848, Vol 10, Sec 3
frequency. The second is a swept frequency test, in which the
frequency of excitation is changed in intervals of 1Hz, and held CED6 E10848, Vol 4, Sec 13
at each frequency for five minutes. The excitation frequencies HED4, ED6 E10848, Vol 4, Sec 11
run from 4 to 33Hz, and the test is conducted in each of the FXD6, HFD6, HHFD6 E10848, Vol 4, Sec 17
three orthogonal axes of the breaker.
HHJD6 E10848, Vol 4, Sec 20
During these tests, the breaker must not trip from the closed
position, nor may the contacts touch from the open position.
Calibration and insulation resistance are also verified during the test.
For detailed information, refer to UL 489, Supplement SB.

7-146 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 06/30/19

Molded Case Circuit Breakers


Internal Accessories General

Feature Combinations
The available feature combinations are shown in the chart below. For applications requiring combinations
of features not listed in this chart, consult the sales office for availability.

Modules Avail. On ST/ UVT/ Elect.


Per Breaker ST/ ST/ AUX/ UVT/ UVT/ AUX/ AUX/ Bell Ground Grd fault
Breakers Breaker Poles ST AUX ALSW ALSW UVT AUX ALSW ALSW AUX ALSW ALSW Alarm fault w/Bell
QP, BQ, BLa 1 1, 2, 3 1 — — — — — 1,2 — — — — —
BQD, CQD, GB, GG 1 2, 3 1 1/1 — — — — 1,2 1/1 1 — — —
QR 1, 2 2, 3 1 1/1 — — — — 2 — — — — —
All ED 1 1, 2, 3 1 1/1,1/2 1/1 1/1/1 1 1/1, 1/2 1/1 1/1/1 1, 2 1/1, 2/1 1 — 1 1
All FD 2 2, 3 1 — — — 1 1/1 — — 1, 2 1/1 1 — — —
All JD, LD, LMDb 2 2, 3 1 1 — — 1 1/1, 1/2 — — 1, 2 1/1, 1/2 1, 2 — — —
SJD, SHJD,
SCJD,SLD, 1 3 1 1 — — 1 1/1, 1/2 — — 1, 2 1/1, 1/2 1, 2 — — —
SHLD, SCLDc
All MD, ND, PD, RD
Including Electronic 2 2, 3 1 1/1 — — 1 1/1, 1/2 — — 1, 2 1/1, 2/1 1, 2 — — —
tripd

Shunt Trip (ST) Alarm Switch (ALSW)


One or all critical circuit breakers may voltage returns to 85% of line voltage. The The alarm switch contact is closed when
be tripped from a distant control point undervoltage trip, which is continuously the circuit breaker is opened automatically
by use of a shunt trip device. A shunt energized, must be energized before the by an overload, short circuit, shunt trip or
trip operates through an auxiliary switch circuit breaker can be closed. undervoltage trip. The alarm switch
contact; when the breaker opens, current Auxiliary Switch (AUX) contact is open when the circuit
is not maintained on the shunt trip coil. breaker is reset.
For applications requiring remote “on” or
Undervoltage Trip (UVT) “off” indication (or electrical interlocking),
When voltage drops to a value below 35% auxiliary switches are available. Each
of the nominal coil rating, the undervoltage switch comprises an “A” (open when
trip device automatically opens the breaker. circuit breaker is open) and a “B” (closed
The operation is instantaneous, and the when circuit breaker is open) contact with
circuit breaker cannot be reclosed until the a common connection. (Form C)

7
CIRCUIT BREAKERS
MOLDED CASE

S01FD60 S01FD60
For ED Frames For FD Frames For JD and LD Frames

a Factoryassembled only cIfmechanical interlock is installed, no accessory module


b If
mechanical interlock is installed, no accessory module can be installed.
can be installed in the right pocket. d If
mechanical interlock is installed, no accessory module
can be installed in the left pocket.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-147


Circuit Breakers
Circuit Breaker Accessories 

Circuit Breaker Accessories 


Catalog Number For Use With Breaker Type Number of Poles Standard Package

Padlocking Device
For locking breaker in “OFF” position. Note “ON” position does not affect breaker fuctionally
ECPLD1 Type QP, BL, QAF2, QPF2, QE, QT-Duplex, BQ, BQXD 1P 3 Pieces
ECPLD1R Type QP, BL, QAF2, QPF, QE, QT-Duplex, BQ, BQXD 1P 3 Pieces
(Red Color)
ECPLD2 Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, 2P 3 Pieces
BQXD
ECPLD2R Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, 2P 3 Pieces
BQXD (Red Color)
ECPLD3 Type QP, BL, QAF2, QPF, QE, BQ 3P 1 Piece
US2:ECPLD3R Type QP, BL, QAF2, QPF, QE, BQ (Red Color) 3P 1 Piece
ECQLD3 Type QP, BL, BQ, BQXD 1P 10 Pieces
ECQLD4 Type QT-Duplex QT-Duplex Breakers 10 Pieces
ECQLN3 150-225 MBKA, QN, QNR n/a 1 Piece
ECQTH4 Type QP, BL, BQH Designed for (3) 1P Breakers 1 Piece

Handle Tie
Provide simultaneous swiching of 2 adjacent handles.
ECQTH2 Type QT Duplex Designed for (2) QT Duplex Breakers 25 Pieces
ECQTH3 Type QP, BL 2P 50 Pieces

Mechanical Interlock
ECQML12 Type QP, BL, BQ Interlock Bracket Designed for 1” Breaker 10 Pieces

Handle Blocking Device


For holding breaker in “ON” or “OFF” position. Not a lockout/tagout device
ECQTH2 Type QP, BL, BQ, BQXD 1P 10 Pieces
ECQTH3 Type QT-Duplex 1/2” Breakers 10 Pieces

Main Breaker Retainer


ECMBR1 EQ Load Centers 1 Piece
ECMBR2 Ultimate Load Centers 1 Piece

Mounting Accessories
7

MB120 Type BQ, BQH Mounting Clips 1P 20 Pieces


FP9508 Type BQ, BQH FACE MOUNT PLATE 1P 10 Pieces
MOLDED CASE
CIRCUIT BREAKERS

FP9555 Type BQ, BQH FACE MOUNT PLATE 2P 10 Pieces


FP9556 Type BQ, BQH FACE MOUNT PLATE 3P 10 Pieces
SMB6R Type BQ MOUNTING BRACKET 1P, 2P, 3P 6 Pieces
TCH65K Type BQ MOUNTING ADAPTER 500 Pieces
BR2 Type BQ, BQH, BQXD Back Mounting Plates 2P 10 Pieces
BR3 Type BQ, BQH, BQXD Back Mounting Plates 3P 10 Pieces
BR4 Type BQ, BQH, BQXD Back Mounting Plates 4P 10 Pieces
I0204ML1125CU Type QP Back Mounting Plates 1P, 2P 10 Pieces
I0303ML3100CU Type QP Back Mounting Plates 3P 10 Pieces

Replacement Lugs
TA1Q1 Type BQ, NGG 100A Al Cu LGS n/a 6 Pieces
TC1Q1 Type BQ, NGG 40A Al Cu LUGS n/a 6 Pieces

Finger Shield
BQFS1K Type BQXD Finger Shield (Bulk Pack) n/a 1000 Pieces
BQFS2 Type BQXD Finger Shield n/a 2 Pieces

Filler Plate
ECQF3 1” Filler Plate n/a 5 Pieces

 For a complete list of standby power mechanical  QP Type includes QPH, HQP  QAF2 Type includes QAFH2, BAF2, BAFH2, QFGA2,
interlock kits, see page 1-25  BLType includes BLH, HBL QFGAH2, BFGA2, BFGAH2
 For use with Ultimate Load Center Main Breakers  BQ Type includes BQH, HBQ  QPF Type includes QPHF, BLF, BLHF
 Not suitable for use on 15-50A, 10 AIC Type QP Circuit  QE Type includes QEH, BLE, BLEH
Breakers

7-148 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Circuit Breakers
Circuit Breaker Accessories General

Padlocking Device

ECPLD1 ECQLD3

ECPLD1R/2R/3R (Single pole


ECPLD2 pictured. 2-/3-pole available) ECQLD4 ECQTH4

Handle Tie Handle Blocking Device

ECQL1

ECBX231M

ECQTH2 ECQTH3

Main Breaker Retainer Mechanical Interlock

7
CIRCUIT BREAKERS
MOLDED CASE
ECMBR1 ECMBR2 ECQML12

Mounting Accessories

FP9508

FP9556

MB120 SMB6R I0204ML1125


FP9555

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-149


Revised on 02/28/19

Molded Case Circuit Breakers


External Accessories Selection

Handle Ties with Padlock Device


Provide simultaneous switching of 2 or 3 adjacent handles.
Do not provide common trip.
For Use With Catalog Standard Wt Lb/
Breaker Frame(s) Number Package Std Pkg
BQDHT2 10 1
⁄2
BQD, NGB, HGB, LGB
BQDHT3 10 1
⁄2

Padlocking Devices
For locking breaker in “OFF” position.
All QR HPLQR 1 1
⁄4
All BQD, CQD, NGB, HGB, LGB BQDPLD 01 1
⁄8
NGG, HGG, LGG HPLG 01 1
⁄4
FD Padlocking
All ED ED2HPL 01 1
⁄4 Device
All FD FD6PL1 01 1
⁄4 FD6PLI
All JD, LD, LMD JD6HPL 01 1
⁄4
All MD, ND, PD, RD MN6PLD 01 1
⁄4

Handle Blocking Devices


For holding breaker in “ON” or “OFF” position.
Not a lockout/tagout device.
All QR HBLQR 1 1
All BQD, CQD, GG, GB BQDHBD 01 ⁄4
1

All ED E2HBL 01 ⁄4
1

All FD FD6HB1 01 ⁄2
1

All JD, LD, LMD JD6HBL 01 ⁄2


1

All MD, ND, PD, RD MN6BL 01 1


⁄2
FD Handle
Blocking Device
Handle Extensions FD6HB1
For replacement. One extension shipped with breaker.
7

All MD, ND, PD, RD EX11 01 2


MOLDED CASE
CIRCUIT BREAKERS

Terminal Shields
Catalog Standard
Breaker Type Poles Number Package
HGG, LGG, NGG 3 TSSG3A 1
JD, LD 3 JDTERMSHIELD 1
MD, ND, PD, RD 3 MDTERMSHIELD 1

Handle
Extension
EX11

n Built to order. Allow 2–3 weeks for delivery.


aS
 old only in standard package quantities.

7-150 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 02/28/19

Molded Case Circuit Breakers


External Accessories Selection

Face Mounting Plates


For Use With Number Catalog Standard Wt Lb/
Breaker Frame(s) of Poles Number Package Std Pkg
1 CQDFMB1 1 1
⁄4
CQD, CQD6 2 CQDFMB2n 1 1
⁄4
3 CQDFMB3n 1 1
⁄4
1 FMPG1 1 1
⁄4
NGG, HGG, LGG 2 FMPG2 1 1
⁄4
3 FMPG3 1 1
⁄4

Back Mounting Plates


ED2, ED4, ED6, HED4, HED6 1 E2BMB 1 1
⁄4
Mounting Screw Kit
MSE6
Mounting Screw Kits
CQD, CQD6 CQDSMK a 1 11⁄4
NGG, HGG, LGG MSKG4a 1 1
⁄4
All QR MSQR3 1 1
⁄5
MSE6a 1 ⁄4
1
All ED (CED6 requires 2 kits)
MSE6100b 100f 1
MSF6a 1 ⁄4
1
All FD (CFD6 requires 2 kits)
MSF650c 50f 1
All EG 1-pole MSKE1 — —
All EG 2-pole MSKE2 — —
All JD, LD MSJ6a 1 1
⁄4
All LMD MSLMD 1 1
⁄4
All MD, ND, MSMN 1 1
⁄4
All PD, RD MSPR6 1 2 Mechanical Interlock
MI5444

“MI” Mechanical Interlocks


For Use With Panel g Plug-in Standard Wt Lb
Breaker Type(s) Mounted Mounted Package Std Pkg
All QR (Sliding Bar) SBMIQR — 1 11⁄2
All FD MI5444 MI5444 1 —

7
All JD, LD MI5413 d — 1 1
All LMD MI5406 dn — 1 1

CIRCUIT BREAKERS
MOLDED CASE
All MD MI5404 en — 1 3
All ND MI5404 en — 1 3
All PD, RD MI5405es — — —

n Built to order. Allow 2–3 weeks for delivery. dW


 ith mechanical interlock in place, no accessory can be gM
 echanical
interlock is not designed for use within
installed into circuit breaker right pole. Siemens panelboards.
s Built to order. Allow 6–8 weeks for delivery. eA
 ddition of the mechanical interlock will prevent
a Kit consists of 4 screws and washers. accessory installation in the left pole.
b Consists of 1 screw and washers (order 100). fS
 old only in standard package quantities. Multiply List
c Consists of 1 screw and washers (order 50). Price Each times package quantity for full price.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-151
Revised on 02/28/19

Molded Case Circuit Breakers


External Accessories Selection

Rotary Door Mounted Operating Handles


Types 1, 3, 3R , 12, 4 4X
Breaker
Complete Mechanism Handle Only Operator Shaft Only
For Use
With Catalog Number
Breaker Standard Variable Catalog Catalog Length Catalog
Frames Depth Depth Number Number (inches) Number
a
ED CRHOESD CRHOEVD RHOEBO 2 RHOSSD
FD CRHOFSD CRHOFVD c RHOFBO 12 RHOSVD
CRHOH
JD, LD CRHOJSD CRHOJVD RHOJBO 16 RHOSXD RHOH
LMD CRHOLMSD CRHOLMVD RHOLMBO
3 RHONSSDs
MD, ND c d
RHONSD RHONVD RHOH RHONBO 12 RHONSVD
PD, RD
24 RHONSXD

Rotary Door Mounted Operating Handles


Types 1 & 12
For Use With Standard Depth Variable Depth Handle and Shaft Breaker Operator
Breaker Frames Catalog Number Catalog Number Catalog Number Catalog Number
e
CQD, NGG, HGG, LGG — RHOCQVD RHOH62 CQDOP
CRHOH
ED D11CEU1 D11CEU2 — —
FD D11CFU1s D11CFU2 — —
JD, LD — D11CJU2 — —
For CQD, NGG, HGG and LGG red emergency handle, order assembly RHOCQVDE (includes handle and operator).s
For CQD, NGG, HGG and LGG in a NEMA 3R enclosure, order CQDOP34 operator, RHOH handle and RHOSVD shaft.
For CQD, NGG, HGG and LGG in a NEMA 4 or 4X enclosure, order CQDOP34 operator, RHOH4 handle and RHOSVD shaft.

Through Door Mounted Operating Handlesb


Types 1 & 12
For Use With Standard Depth Variable Depth D11CEU2
Breaker Frames Catalog Number Catalog Number
CQD, NGG, HGG, LGG FMHOS —
ED E2RH1 E2RHV9
FD F6RH1 F6RHV9
7

Door Latch Kits


MOLDED CASE
CIRCUIT BREAKERS

Catalog Number Catalog Number


Type Right Hand Left Hand
2 point latch DKR2 DKL2n
3 point latch DKR3 DKL3n

Standard Depth F6RH1

Variable Depth F6RHV9


Rotary Handle RHOCQVD

n Built to order. Allow 2–3 weeks for delivery. b Meets the requirements of NFPA 79, section 5.3.3.1 d For
 extended shaft support order catalog number
for locking external operator disconnecting devices. RHONSB2.
s Built to order. Allow 6–8 weeks for delivery. c For e Lengthof shaft is 300mm (11.8 inches).
 3 or 3R, order shaft and breaker operator as shown, 
a For
 use on 3-pole ED frame only. and handle RHOH. For 4 & 4X, order handle RHOH4.
Consult sales office for additional EG operator shaft
lengths.

7-152 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 02/28/19

Molded Case Circuit Breakers


External Accessories Selection

Max-Flex™, Flange Mounted Variable Depth Operators c


Complete Kit Handle Only
NEMA Catalog Catalog Breaker Operator 36" Cable
Frames Type Number Number Catalog Number Catalog Number
FHOH
1, 3 (R),
MFKG3R3 MFHG3R
GG 12 MFMG MFCF036
4 (x) MFKG4X3 MFHG4X
1, 3 (R),
FHOE036 a FHOH
ED 12 FHOEBOa FHOEC036
4 (x) — FHOH4
1, 3 (R),
FHOF036 FHOH
FD 12 FHOFBO FHOFC036
4 (x) — FHOH4
1, 3 (R),
JD, LD, FHOJ036 FHOH
12 FHOJBO FHOJC036
SJD, SLD
4 (x) — FHOH4
1, 3 (R),
FHOLM036 FHOH
LMD 12 FHOLMBO FHOJC036
4 (x) — FHOH4 FHOFBO
MD, ND, 1, 3 (R),
FHON048 FHOHN
PD, RD, 12
FHONBO FHONC048b
SMD, SND,
SPD 4 (x) — FHOHN4

Max-Flex™ handles are available with solid black handles instead of the customary “red for on” flange handle. These are
preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the
letter “i” to the catalog number (e.g. FHOHI).

Alternate Length Cable Only


ED FD JD/LD/LMD MD/ND/PD/RD

Inches Catalog Number Catalog Number Catalog Number Catalog Number
048 FHOEC048 FHOFC048 FHOJC048 FHONC048
060 FHOEC060 FHOFC060 FHOJC060 FHONC060
072 FHOEC072 FHOFC072 FHOJC072 FHONC072
96 FHOEC096 FHOFC096 FHOJC096 FHONC096
120 FHOEC120s FHOFC120 FHOJC120s FHONC120s
144 FHOEC144s FHOFC144s FHOJC144s FHONC144s

7
FHOFC036
Handle Auxiliary Switch

CIRCUIT BREAKERS
MOLDED CASE
For use with Max-Flex and Rotary Door operators (FHOH and RHOH). 1 NO and 1 NC contact (Form C).
For Use With Catalog Number
ED, FD, JD, LD, LMD, ND, PD, RD, SD, Max Flex HAS1

FDFBFR
Fixed Depth Flange Mounting
Minimum Left Hand Mount Right Hand Mount
Enclosure NEMA
Frames Depth Type Catalog Number Catalog Number
 1, 3R, 12 FDFBELs FDFBERs
ED 6.44
4, 4X FDFBEL4s FDFBER4s
1, 3R, 12 FDFBFLs FDFBFRs
FD 6.44
4, 4X FDFBFL4s FDFBFR4s
Max-Flex™ handles are available with solid black handles instead of the customary “Red for On” flange handle. These are
preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the
letter “i” to the catalog number (e.g. FHOHI).

s Built to order. Allow 6–8 weeks for delivery. b48inch cable is standard length for M through R frame dConsult sales office for additional cable lengths for EG
aFor Max-Flex operators. Flex Shaft Operators. For 3-Pole only.
1- or 2-pole breaker order FHOED036 complete kit or cMeets requirements of NFPA 79, section 5.3.3.1 for 3-Pole ED only.
FHOEDBO breaker operator only. Use MFHM3R handle.
locking external operator disconnecting devices

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-153
Molded Case Circuit Breakers
External Accessories Selection/Dimensions

Telemand® Motor Operator


AC Hinged to Open Down
Breaker Frame Voltage Catalog Number
120 MOE6120
ED except CED
240 MOE6240 s
ED motor operator opens downward.

Breaker DC Hinged to Open Right AC Hinged to Open Right


Frame Voltage Catalog Number Voltage Catalog Number
24 MOF6024DCs 120 MOF6120
FD 48 MOF6048DCs 240 MOF6240
125 MOF6125DCs
24 MOJ6024DCs 120 MOJ6120
JD, LD 48 MOJ6048DCs 240 MOJ6240
125 MOJ6125DCs
24 MOLMD6024DCs 120 MOLMD6120 Telemand Motor Operator
LMD 48 MOLMD6048DCs 240 MOLMD6240
125 MOLMD6125DCs
MD, ND, — — 120 EMOPL120MN
PD, RD — — 240 EMOPL240MN FD, JD, LD, LMD, MD, ND, PD, RD
Frames
To order FD through RD motor operators with Left side hinges, add “L” to catalog number (e.g. MOF6120L).
List prices are the same.s

Dimensions
Frame A B C D E F
ED 7.04 4.31 — 4.31 13.84 8.84
FD 9.50 4.55 1.60 6.84 9.70 7.58
JD, LD, LMD 11.00 7.50 0.79 8.34 9.85 7.74
MD, ND, PD, RD 16.00 9.00 — 9.83 13.13 10.13

Operating Currents
On Off
Catalog In-Rush Running Time In-Rush Running Time Reset
Number (Amps) (Amps) (msec) (Amps) (Amps) (msec) (Amps)
7

MOE6120 10.25 2.3 550 10 2.3 400 2.3


MOE6240 5.2 1.1 500 5 1 330 1.1 Front View
MOLDED CASE
CIRCUIT BREAKERS

MOF6120/L 13.6 5.5 200 13.6 5.5 175 5.5


MOF6240/L 7.6 3.5 200 7.6 3.5 185 3.5
MOLMD6120/L 13.6 6 210 13.6 6 185 6
MOJ6120/L 13.6 6 210 13.6 6 185 6
MOJ6240/L 7.6 3.5 217 7.6 3.5 185 3.5
EMOPL120MN 15 5.5 500 15 5.5 500 5.5
EMOPL240MN 7.6 3.25 500 7.6 3.25 500 3.25

Bottom View

For inches / millimeters conversion, see Application Data section.

s Built to order. Allow 6–8 weeks for delivery.

7-154 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 02/28/19

Molded Case Circuit Breakers


External Accessories Selection

Plug-In Mounting Assemblies, Including Base and Tulip Assemblies


Line Side Load Side Base
Steel Switchboard
For Use With Mounting Plate a
Breaker Frames Poles Catalog Numberb Catalog Numberb Catalog Number
All ED 2 PC2637s PC2638s
PL2616
except CED 3 PC2657 PC2658
2 PC2637s PC2638s
CED PL2617
3 PC2657 PC2658
All FD 2 PC4753s PC4753s
PL4762
except CFD 3 PC4754 PC4754
2 PC4753s PC4753s
CFD PL4763
3 PC4754 PC4754
All JD 2 PC5777s PC5777s
PL5796
except CJD 3 PC5778 PC5778
Kit CJD, SCJD 3 PCCJD PCCJD PL5797
All LD 2 PC5660s PC5660s Tulip
PL5680
except CLD 3 PC5661 PC5661 Switchboard Assemblies
Kit CLD, SCLD 3 PCCLD PCCLD PL5797 Mounting
Plate
2 PC5662s PC5662s
All MD PL9698
3 PC5663 PC5663
2 PC5664 s
c
PC5664 s
c

All ND PL9699
3 PC5666 c PC5666 c

Tulip Assemblies Separately


For 2-Pole 3-Pole RS4755
Frame Catalog Number Catalog Number RS4756
ED TCE2s TCE3s
FD TCF2s TCF3s
JD TCJ2s TCJ3s
LD TCL2s TCL3s
MD TCM2s TCM3s
ND TCN2s TCN3s

7
Rear-Connecting Studs Circuit Breaker

CIRCUIT BREAKERS
MOLDED CASE
With Rear-Connecting Studs
For Use Extension
With Behind Line Side Load Side
Breaker Ampere Breaker
Frames Rating Description (inches) Catalog Number d Catalog Number d
100 Line Side (Short) 2.38 RS2643 s e

100 Load Side (Short) 2.38 — RS2644es
All ED
100 Line Side (Long) 4.88 RS2641es —
100 Load Side (Long) 4.88 — RS2642es
250 Short 3.12 RS4756es RS4756es
All FD
250 Long 7.06 RS4755es RS4755es
400 Short 5.85 RS5774s RS5774s
All JD
400 Long 11.20 RS5773s RS5773s
600 Short 5.85 RS5784s RS5784s
All LD
600 Long 11.20 RS5783s RS5783s
CJD, SCJD
Add required shield kit. CLRSJL3
CLD, SCLD
LM(X)D6, Short 5.85 RS5788s RS5788s
800
HLM(X)D6 Long 11.20 RS5787s RS5787s
All MD, 1200 Short 5.50 RS5786s RS5786s
ND 1200 Long 8.00 RS5785s RS5785s

s Built to order. Allow 6–8 weeks for delivery. c For vertical bus mounting — for horizontal, substitute e For proper electrical clearance, studs must alternate
aMust PC5665 for PC5664 and PC5667 for PC5666. between short and long stud lengths on circuit breaker
be ordered separately with other plug-in d Price includes one current stud, insulating tube, stud poles (e.g. SLSLSL or LSLSLS).
assemblies.
bEach piece catalog number consists of (1) mounting nuts and terminal shields, when required. f Plug-in assembly for EG breakers include line and load
side in one assembly.
block assembly and required tulip assemblies (2) for
2-pole, (3) for 3-pole

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-155
Revised on 05/31/18

Molded Case Circuit Breakers


Unusual Operating Conditions Reference

Note: The information provided on this and the next page is intended for reference and recommendation only. Because several
variables can act on a circuit breaker’s performance at the same time, the data below is based less on controlled testing,
than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment.
High Ambient Temperatures Table 1 — Temperature Derating Data for Thermal-Magnetic Breakers
Because thermal-magnetic trip breakers Reference
are temperature sensitive and calibrated Ampere Rating at:
Ampere
for a specific ambient of 40° C (104° F) Rating at 50°C 60°C
(average enclosure temperature), a 40°C (104°F) (122°F) (140°F) Siemens Breaker Frames
higher ambient will cause the breaker to 15 13 11
trip at lower current than its nameplate 20 18 16
rating, in other words, causing the 25 23 21 BQ,
breaker to “derate” (see Table 1). 30 28 26 BL,
Similarly, the current carrying capacity 35 30 28 BQD,
of a circuit conductor is based upon a 40 37 34
certain ambient temperature, a higher 50 46 42
CQD,
ambient will reduce its current carrying 60 56 52 GG,
capacity, causing it to “derate.” Thus, 70 65 60 GB,
with a fluctuating temperature, a 90 84 78
thermal-magnetic breaker will derate ED
100 94 87
nearly parallel with its connected circuit
125 114 100
conductors and maintain close circuit
150 136 120 FD
protection. If the application temperature
exceeds 40° C (104° F) and is known, 175 159 140 QR
either a breaker specially calibrated for 200 182 160
the higher ambient or one oversized 225 205 180
according to Table 1 may be selected. 250 235 220
JD
In a case such as this, the circuit 300 276 252
conductors should be oversized as well. 350 325 301
LD
400 372 340
Siemens Sensitrip® IV and Type SB
500 468 435
Encased Systems Breakers are
insensitive to temperature changes. 600 564 525
MD
However, they do include circuitry to 700 658 613
protect the components from 800 754 704
abnormally high temperatures. 900 828 749
ND
1000 900 825
Moisture — Corrosion
1200 1090 1000
For atmospheres having high moisture 1400 1304 1148 PD
content and / or where fungus growth is 1600 1500 1320
prevalent, a special preventive treatment
7

1800 1690 1485 RD


may be required. 2000 1880 1650
Where the air is heavily laden with
MOLDED CASE
CIRCUIT BREAKERS

corrosive elements, breakers made


with special corrosion-resistant 13,000 (4,000)
finishes may be required.
12,000 (3,675)
Altitude
Altitude in Feet (Meters)

Reduced air density at altitudes greater 11,000 (3,350)


than 6600 ft. (2000 meters) affects the
10,000 (3,000)
ability of a molded case circuit breaker
to transfer heat and interrupt faults. 9,000 (2,750)
Therefore, circuit breakers applied at
these altitudes should have interrupting, 8,000 (2,400)
insulation and continuous currents
derated as indicated in Figure 1. 7,000 (2,100)

6,000 (1,800)

1.0 .95 .90 .85 .80 .75

Rating Correction Factor

Figure 1 — Altitude Adjustment

7-156 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Molded Case Circuit Breakers
Unusual Operating Conditions Reference

400 Hz Systems a
Siemens molded case circuit breakers ambient temperature exceeds 40° C are usually the hottest terminals with a
can be applied for overcurrent protection (104° F). balanced load. A maximum temperature
on 400Hz systems, commonly used to Cable and Bus Sizing of 75° C (35° C over a maximum ambient
power computer installations, aircraft, of 40° C) would verify the particular
military and other specialty equipment. The cable and bus sizes to be utilized application. Temperature profiles taken
Below are basic guidelines. at 400Hz are not based on standard on these breakers can be correlated to
National Electric Codes tables for 60Hz ensure that the hottest points within
Circuit Breaker Derating Required application. Larger cross sections are the breaker are within the required
This table lists the maximum continuous necessary at 400Hz. All bus bars temperature limits.
current carrying capacity for Siemens specified are based upon mounting
breakers at 400Hz. Due to the increased the bars in the vertical plane to allow Factory Configuration
resistance of the copper sections maximum air flow. All bus bars are When required, molded case circuit
resulting from the skin effect produced spaced at a minimum of 0.25 in. (6 mm) breakers may be factory calibrated for
by eddy currents at these frequencies, apart. Mounting of bus bars in the 400Hz application. These breakers are
circuit breakers in many cases require horizontal plane will necessitate specially labeled for 400Hz usage and
derating. The thermal derating on these additional drafting. Edgewise orientation their nameplate current rating will
devices is based upon 100%, of the bus may change the maximum include the necessary derating factory.
three phase application in open air in a ratings indicated. If additional information The highest “Maximum Continuous
maximum of 40° C (104° F) with 48 in. is required for other connections of cable Amperes” rating at 400Hz, found in the
(1219 mm) of the specified cable or bus or bus, contact Siemens for information. table below approximates the highest
at the line and load side. Additional Application Recommendations specially calibrated 400Hz nameplate
derating of not less than 20% will be ampere rating available for a given
required if the circuit breaker is to be It is recommended that temperatures be
measured on the line and load terminals frame size. Contact Siemens for
utilized in an enclosure. Further derating ordering information on other
may be required if the enclosure or T-connectors of the center pole. These
breakers applied in 400Hz systems.

400Hz Breakers
Maximum Continuous Ampere Rating 75°C (167° F) Maximum Continuous Ampere Rating 75° C (167° F)
At 40°C (104°F) b Copper At 40° C (104° F) b Copper
Siemens 60HZ 400HZ Cable per Pole Siemens 60HZ 400/415HZ Cable per Pole
Breaker Enclosed No of Wire Breaker Enclosed No of Wire
Type Open Air Open Air c After Derating Pieces Size Type Open Air Open Air c After Derating Pieces Size
015 015 012 1 #14 0250 0210 168 1 250 kcmil
020 020 016 1 #12 0300 0240 192 1 350 kcmil
025 025 020 1 #10 LD6, LXD6, 0350 0260 208 1 500 kcmil
HLD6, HLXD6,
030 030 024 1 #10 HHLD6, 0400 0300 240 2 #3/0
035 035 028 1 #10 HHLXD6, 0450 0340 272 2 #4/0
CLD6
040 040 032 1 #8 0500 0375 300 2 250 kcmil
ED2, ED4, ED6, 045 043 034 1 #8 0600 0420 336 2 350 kcmil
BQD, HED4, 050 048 038 1 #8 0250 0210 210 1 250 kcmil
HED6, CED6, 060 057 046 1 #6 0300 0240 240 1 350 kcmil

7
GG, GB
070 067 054 1 #4 0350 0260 260 1 500 kcmil
LD6, LXD6,
080 076 061 1 #4 HLD6, HLXD6, 0400 0300 300 2 #3/0
100% Rated

CIRCUIT BREAKERS
MOLDED CASE
090 086 069 1 #3 0450 0340 340 2 #4/0
100 095 076 1 #3 0500 0375 375 2 250 kcmil
110 105 084 1 #2 0600 0420 420 2 350 kcmil
125 119 095 1 #1 0500 0400 320 2 250 kcmil
070 063 050 1 #4 MD6, MXD6, 0600 0430 360 2 350 kcmil
HMD6,
080 072 058 1 #4 HMXD6, CMD6 0700 0500 400 3 250 kcmil
090 080 064 1 #3 0800 0560 448 3 300 kcmil
QR2, QR2H, 100 090 072 1 #3 0500 0400 400 2 250 kcmil
MD6, MXD6,
HQR2, HQR2H, 110 095 075 1 #2 HMD6, 0600 0430 430 2 350 kcmil
FD6, FXF6, 125 105 084 1 #1 HMXD6, CMD6 0700 0500 500 3 250 kcmil
HFD6, HFXD6, 100% Rated
CFD6 150 125 100 1 #1/0 0800 0560 560 3 300 kcmil
175 140 112 1 #2/0 0800 0560 448 3 300 kcmil
200 160 128 1 #3/0 ND6, NXD6 0900 0600 480 3 350 kcmil
HND6, HNXD6,
225 180 144 1 #4/0 CND6 1000 0650 520 3 400 kcmil
250 200 160 1 250 kcmil 1200 0780 624 4 350 kcmil
200 170 136 1 #3/0 ND6, NXD6 0900 0600 600 3 350 kcmil
225 190 152 1 #4/0 HND6, HNXD6, 1000 0650 650 3 400 kcmil
JXD2, JD6, CND6
JXD6, HJD6, 250 210 168 1 250 kcmil 100% Rated 1200 0780 780 4 350 kcmil
HJXD6, HHJD6, 300 240 192 1 350 kcmil 1200 0780 624 4 400 kcmil
HHJXD6, CJD6 350 PD6, PXD6,
260 208 1 500 kcmil HPD6, HPXD6, 1400 0850 680 4 500 kcmil
400 300 240 2 #3/0 CPD6, 1600 0960 768 5 500 kcmil
200 170 170 2 #3/0 PD6, PXD6, 1200 0780 780 4 400 kcmil
225 190 190 2 #4/0 HPD6, HPXD6, 1400 0850 850 4 500 kcmil
JD6, JXD6, CPD6
HJD6, HJXD6 250 210 210 1 250 kcmil 100% Rated 1600 0960 960 5 500 kcmil
100% Rated 300 240 240 1 350 kcmil RD6, RXD6, 1600 0960 768 5 500 kcmil
350 260 260 1 500 kcmil HRD6, HRXD6 1800 1080 864 5 500 kcmil
400 300 300 2 #3/0 80% Rated 2000 1200 960 6 500 kcmil
aThe information provided on this page is intended for controlled testing, than on experience and engineering temperature is greater than 40°C (104°F).
reference and recommendation only. Because several judgment. Contact Siemens for further information on cCalculatedafter derating to compensate for the heating
variables can act on a circuit breaker’s performance at special conditions and treatment. of the copper conductor, caused by the skin effect
the same time, the data above is based less on bAdditional derating may be required if the ambient generated by eddy currents produced at 400/415HZ.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-157


Molded Case Circuit Breakers
Notes
7 MOLDED CASE
CIRCUIT BREAKERS

7-158 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


VL Circuit Breakers
Catalog Numbering System Selection/Application

Interrupting Class
N — Normal
H — High
L — Very High
C — Trip Unit Only
Frame Family
D — Type DG L — Type LG P — Type PG
F — Type FG M — Type MG
J — Type JG N — Type NG
Breaker Type
E — Global DG, FG Frame Only R­ ­—
Molded Case Switch
600 Y/347 V (DG, FG, LG-frame)
G — Global interchangeable (UL, S — Molded Case Switch
IEC, CE, CSA, NOM, CCC) T — Trip Unit Only
J — 240V rated JG frame, V — Thermal Magnetic, standard 40°C
Non-interchangeable only ambient, 600VAC 25kA, UL/CSA
K — Global, Non-interchangeable (LG frame)
(DG, FG, LG-frame) W — 100% rated, Non-interchangeable
M — Motor Circuit Protector (DG, LG-frame)
P — Motor Circuit Protector X — Global Non-interchangeable
(DG, FG Only) Y — 100% rated, Non-interchangeable

Number of Poles
2, 3
Trip Unit
F — Frame only, without trip unit S — Molded Case Switch
B — Thermal Magnetic, standard 40° C ambient A — Electronic w/ LCD, LSI or 3P (neutral protected)
L — Magnetic Only, Motor Circuit Protector - Low G — Electronic w/ LCD, LSIG, 3P/4W (selectable residual or
instantaneous range return type ground fault protection)
J — Magnetic Only, Motor Circuit Protector - Low K — Electronic with LCD, LSI and GF alarm only, 3P/4W
instantaneous range (LG-frame) (selectable residual or return type ground fault alarm)
M — Magnetic Only, Motor Circuit Protector - Standard R — Electronic LI or 3P (neutral protected)
instantaneous range T — Electronic LSI or 3P (neutral protected)
Y — Magnetic Only, Motor Circuit Protector - Standard V — Electronic, LSIG or 3P/4W, residual ground fault protection
instantaneous range (LG-frame) W— Electronic, LIG or 3P/4W, residual ground fault protection
H — Magnetic Only, Motor Circuit Protector - High
instantaneous range
Continuous Current Rating
For DG use 050, 060, 070, 080, 090, 100, 110, 125, 150
For FG use 100, 110, 125, 150, 175, 200, 225, 250

7
For JG use 250, 300, 350, 400
For LG use 400, 500, 600
For MG use 600, 700, 800

CIRCUIT BREAKERS
MOLDED CASE
For NG use 800, 900, 100 (1000A), 120 (1200A)
For PG use 120 (1200A), 140 (1400A), 160 (1600A)
Terminations
B — Load End Standard (cu/al) Lugs
L — Line & Load Standard (cu/al) Lugs
X — No Lugs (use only if accessory suffixes are to follow)
Accessories
Auxiliary and Alarm Switch Combinations
Suffix Description
A1 — 1 Alarm (includes 1NO & 1NC switch with a 2 Aux./1 Alarm Base, for frames DG to LG) Note: A1 and A3 include 1NO and 1NC switch for
A2 — 2 Aux (1NO & 1NC switch with a 3 Aux. Base, for frames DG to LG) alarm purposes, only one of these switches may
A3 — 2 Aux + 1 Alarm (2NO & 2NC switches with a 2 Aux./1 Alarm Base, for frames DG to LG) be used as there is only one space for an alarm.
A3 — 2 Aux + 2 Alarm (2NO & 2NC switches with a 2 Aux./2 Alarm Base, for frames MG to PG)
A4 — 4 Aux (2NO & 2NC switches with a 4 Aux. Base, for frames MG to PG)
Shunt Trips
RB — 24 VDC RM — 48-60 VAC
RC — 48-60 VDC RN — 110-127 VAC
RD — 110-127 VDC RS — 208-277 VAC LCD = Liquid Crystal Display
RE — 250 VDC RV — 380-600 VAC LI = Long Delay & Instantaneous trip functions
LSI = Long Delay, Short Delay, & Instantaneous trip functions
Under Voltage Releases LSIG = Long Delay, Short Delay, Instantaneous, & Ground Fault trip functions
UA — 12 VDC UN — 110-127 VAC GF = Ground Fault
UB — 24 VDC UP — 208 VAC 3P = 3-pole
UC — 48 VDC UR — 220-250 VAC 4W = 4-wire
UD — 110-127 VDC US — 277 VAC
UE — 220-250 VDC UT — 380-415 VAC
UG — 60 VDC UU — 440-480 VAC
UK — 24 VAC

 Select Frames

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-159


VL Circuit Breakers
Catalog Numbering System Selection

If ordering factory-installed accessories or special modifications, you must order a 15-digit catalog number. See the examples
below for a detailed explanation. The 15 digit number is achieved by placing X’s in positions not being occupied by an
accessory/modification. Contact Siemens for circuit breakers configured with accessories.

Auxiliary Switch Example:

HFG3B200L A2 XXXX
Standard 9-digit Aux. Switch Completes Cat #

Shunt Trip / UVR Example:

HFG3B200L XX UN XX
Standard 9-digit UVR
Completes Cat #

Shunt Trip / Auxiliary Switch Example:

HFG3B200L A2 RN XX
Standard 9-digit Aux. Shunt Completes
Switch Trip Cat #

Non-Interchangeable Trip Breakers Example:

HFX3B200L
Standard 9-digit
7 MOLDED CASE
CIRCUIT BREAKERS

7-160 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


VL Circuit Breakers
Technical Overview Technical

Frame Summary and Ratings Table


Frame Family DG FG JG

Continuous Ampere Range 30 to 150A 40 to 250A 70 to 400A


Number of Poles 2, 3 2, 3 2, 3
Maximum Voltage Rating 600Y/347 600Y/347 600V
Type of Protection
Thermal-Magnetic u u u
Electronic u u u
Electronic with LCD u u u
Motor Circuit Protector u u u
Molded Case Switch u u u
100% Rated Breaker ETU only — u
Interchangeable Trip Unit — — u
W   In.(mm) 4.1 (105) 5.5 (139)
H 7.3 (175) 11 (279)
D 3.4 (81) 4.2 (102)
D1 4.2 (107) 5.4 (138)
Type N – Normal Interrupting Ratinga, RMS Symmetrical Amperes (kA)
240Vac 65 65 65
UL 480Vac 35 35 35
600Vac 18 18 25
240Vac 65/65 65/65 65/65
IEC 415Vac 40/40 40/40 45/45
(lCU /lCS)
690Vac 12/6 12/6 12/6
DC Voltages – Interrupting Rating (kA)d
250Vdc - 2p 30 30 30
500Vdc - 3pc 18 18 25
Type H – High Interrupting Ratinga, RMS Symmetrical Amperes (kA)
240Vac 100 100 100
UL 480Vac 65 65 65

7
600Vac 18 18 25
240Vac 100/75 100/75 100/75
IEC 415Vac 70/70 70/70 70/70

CIRCUIT BREAKERS
MOLDED CASE
(lCU /lCS)
690Vac 12/6 12/6 15/8
DC Voltages – Interrupting Rating (kA)d
250Vdc - 2p 30 30 30
500Vdc - 3pc 18 25 35
600Vdc - 3p 42 42 65
Type L – Very High Interrupting Ratinga, RMS Symmetrical Amperes (kA)
240Vac 200 200 200
UL 480Vac 100 100 100
600Vac 18 18 25
240Vac 200/150 200/150 200/150
IEC 415Vac 100/75 100/75 100/75
(lCU /lCS)
690Vac 12/6 12/6 15/8
DC Voltages – Interrupting Rating (kA)d
250Vdc - 2p 30 30 30
500Vdc - 3pc 18 30 35

a  L does not recognize AIC ratings for Molded Case


U c  00Vdc nominal, 600Vdc max. for ungrounded DC UPS
5  DG & FG breakers are 600Y/347V.
Switches or Motor Circuit Protectors. systems.
b For 600 VDC breakers see page 7-194. d DC Interruption Ratings do not apply to electronic trip
circuit breakers.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-161


VL Circuit Breakers
Technical Overview Technical

Frame Summary and Ratings Table — Continued


Frame Family LG MG NG PG

Continuous Ampere Range 150 to 600A 200 to 800A 300 to 1200A 400 to 1600A
Number of Poles 2, 3 2, 3 2, 3 3
Maximum Voltage Rating 600V 600V 600V 600V
Type of Protection
Thermal-Magnetic u u u u
Electronic u u u u
Electronic with LCD u u u u
Motor Circuit Protector u u u —
Molded Case Switch u u u u
100% Rated 400/500 Amp u u u
Interchangeable Trip Unit — u u u
W   In.(mm) 5.5 (139) 7.5 (190) 9 (229)
H 11 (279) 16 (406) 16 (406)
D 4.2 (102) 4.7 (114) 6.2 (157)
D1 5.4 (138) 5.9 (151) 8.1 (207)
Type N – Normal Interrupting Ratinga, RMS Symmetrical Amperes (kA)
240Vac 65 65 65 65
UL 480Vac 35 35 35 35
600Vac 18 25 25 25
240Vac 65/65 65/65 65/65 65/65
IEC 415Vac 45/45 50/50 50/25 50/25
(lCU /lCS)
690Vac 12/6 20/10 20/10 20/10
DC Voltages – Interrupting Rating (kA)d
250Vdc - 2p 30 22 22 22
500Vdc - 3pc 25 35 35 35
Type H – High Interrupting Ratinga, RMS Symmetrical Amperes (kA)
240Vac 100 100 100 100
UL 480Vac 65 65 65 65
7

600Vac 18 35 35 35
240Vac 100/75 100/75 100/75 100/50
IEC 415Vac 70/70 70/70 70/35 70/35
MOLDED CASE
CIRCUIT BREAKERS

(lCU /lCS)
690Vac 15/8 30/15 30/15 30/15
DC Voltages – Interrupting Rating (kA)d
250Vdc - 2p 30 25 25 25
500Vdc - 3pc 35 50 50 50
600Vdc - 3pe 65 65 65 65
Type L – Very High Interrupting Ratinga, RMS Symmetrical Amperes (kA)
240Vac 200 200 200 200
UL 480Vac 100 100 100 100
600Vac 18 50 65 65
240Vac 200/150 ­200/150 200/150 200/150
IEC 415Vac 100/75 100/75 100/75 100/75
(lCU /lCS)
690Vac 15/8 35/17 35/17 35/17
DC Voltages – Interrupting Rating (kA)d
250Vdc - 2p 30 42 42 42
500Vdc - 3pc 35 65 65 65

a  L does not recognize AIC ratings for Molded Case


U c  00Vdc nominal, 600Vdc max. for ungrounded DC UPS
5 e  or 600 VDC breakers see page 7-194.
F
Switches or Motor Circuit Protectors. systems.  Thermal-magnetic available non-interchangeable only.
b 25kA available in a special version. Standard breakers d DC Interruption Ratings do not apply to electronic trip  13.6” with extended shields.
rated 18kA. See page 7-178. circuit breakers.

7-162 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


VL Circuit Breakers
Trip Unit Overview Selection

The interchangeability of the VL circuit mation menus. With precise control factory for each frame and do not
breaker trip units allow for easy conver- over the circuit beaker functions and overlap with the settings on the other
sion from any of 3 types of protection. access to system status, diagnostics, frames. Therefore, when VL breakers
They are thermal-magnetic, electronic, and information, these trip units allow are used together in a system the GF
or electronic with a built-in LCD. The for unsurpassed flexibility in circuit protection is automatically coordinated.
thermal-magnetic trip unit features an coordination. The user also has the ability to program
adjustable magnetic trip setting. The a custom coordination scheme with
electronic trip units are microprocessor An example of coordination is the out adjustable settings on both the 555 and
based true RMS sensing devices and of the box Ground Fault function on the 586 trip units.
are available with a variety of adjustable Model 555 trip units. The pick-up and
trip settings, configurations, and infor- time delay settings are set at the

VL Trip Units
Trip Unit Functions Model 525 Model 555 Model 586
Electronic Electronic Electronic
Thermal- Electronic Electronic Electronic Electronic with LCD with LCD with LCD
magnetic LI LIG LSI LSIG LSI LSIG LSI + G alarm only
Continuous Current Setting (Ir) Fixed u u u u u u u
Long Time Delay (tr) h u u u u u u u
Instantaneous Function l l l l l (ON/OFF) (ON/OFF) (ON/OFF)
Instantaneous Pickup (Ii) u u u u u u u u
Short Time Function h h h l l (ON/OFF) (ON/OFF) (ON/OFF)
Short Time Pick-up (Isd) h h h u u u u u
Short Time Delay (tsd) h h h u u u u u
Ground Fault Pick-up (Ig) h h u h u h u h
Ground Fault Delay (tg) h h u h u h u h
Ground Fault Alarm Pick-up h h h h h h u u
Ground Fault Alarm Delay h h h h h h u u
Alarm & Status Indicator h l l l l l l l
Built-in Display (LCD) h h h h h l l l
Pre-Trip Alarma h l l l l l l l
Last Trip Information h la la la la l l l
Zone Selectivea h l l l l l l l
Communicationsa h l l l l l l l
u Adjustable setting

7
l This feature is included
h Feature is not included.

CIRCUIT BREAKERS
MOLDED CASE
a Requires a COMPRO20 or COMMOD21 module in a communication system.

Continuous Amps Rating (Ir) override function to ensure self protec- Ground Fault Pick-Up (Ig)
This setting is the continuous current tion of circuit breaker. This setting controls the level of ground
that the breaker will carry without trip- fault current that will cause the breaker
ping. It can be set up to 100% of the trip Short Time Pick-Up (lsd) to trip. Model 555 Electronic Trip Units
unit’s nominal rating (In). This function controls the level of fault act on the residual current to sense
current the breaker will carry for a short ground current. The Model 586
Long Time Delay (tr) time without tripping, thus allowing Electronic Trip Unit is programmable
Sometimes referred to as the “overload” downstream devices to clear short cir- and allows the user to select either
position, this function controls the break- cuits ahead of up-stream protection. the residual current method or direct
er‘s “pause-in-tripping” time. It allows It may be defeated (turned-off) on detection (via a separate current trans-
low level, temporary inrush currents Model 586 trip units. former) to detect ground current.
such as those encountered when start-
ing a motor to pass without tripping. The Short Time Delay (tsd) Ground Fault Time Delay (tg)
time delay begins when the current This controls the interval of time the
This controls the interval of time the
reaches 6 x Ir. breaker will remain closed after a ground
breaker will remain closed against a fault
(at the Short Time Pick-up current level) fault is detected (at the Ground Fault
Instantaneous Pick-up (Ii) without tripping. The time delay may be Pick-up current level) without tripping.
This function sets the breaker to trip set at fixed points or at short time inter-
instantaneously during high fault condi- vals based on l2t curves. This function is
tions. This function may be turned off on used with the Short Time Pick-up to
Model 586 trip units. Turning this func- achieve selectivity and better system
tion off will enable an instantaneous trip coordination.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-163


VL Circuit Breakers
General Information Selection

Thermal-Magnetic trip units, Model 525, combine the inverse time element design for low level overloads, and instantaneous
magnetic action for short circuit protection. The standard unit has preset overload protection and an adjustable instantaneous trip
setting, with 6 set points. Thermal-Magnetic trip units are available throughout the VL family, from 50 to 1600A.

Electronic Trip Units


Electronic trip units are available through microprocessor is in operating and displays, no secondary or auxiliary volt-
the VL family, from 60A (which can be another indicates an overload condition. age is required as long as the breaker is
set as low as 30A) up through 1600A. For ease-of-use and to insure proper energized and a minimal load current is
They are also available in four trip coordination, the set points for the present. These trip units can also indi-
configurations (LI, LIG, LSI, LSIG) and continuous current are shown on the cate the “last trip” status (date, time,
features can include a built-in LCD face of these trip units in amps. amps) when they‘re connected to a PC
display. via one of our communications modules.
Without being connected via a communi-
On the Model 586, the LCD version, the cation module, the last trip status can be
On the Model 555 Electronic Trip Unit a current in each phase is continuously viewed on Model 586 trip units (no time
flashing LED confirms that the shown on the display. Unlike many stamp).

Typical Trip Unit Labeling and Adjustment Positions


Model 555 Electronic Trip Unit
with LSIG trip functions
7

Model 586 Electronic Trip Unit


MOLDED CASE
CIRCUIT BREAKERS

has an LCD display

7-164 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


VL Circuit Breakers
DG 150A Frame, VL Series Selection

Ordering Information
Complete Assembled Breaker
A complete factory assembled DG breaker includes the frame, trip unit, and
standard line and load connectors, all factory installed and shipped as a com-
plete breaker. Assembled breakers are only available with standard
connectors.
For DC applications, use thermal magnetic trip unit only.
Breakers are suitable for reverse feed applications.
For special applications, refer to page 7-212.
Mounting hardware is included with each frame or complete breaker.
For 100% rated breakers with a non-interchangeable trip unit, change the 3rd
character of the catalog number to “W”. Available in electronic and electronic
with LCD only.
HACR rated.

Interrupting Ratings
RMS Symmetrical Amperes (KA)
UL 489 IEC 60947-2
Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) Dimensions, inches (mm)
Interrupting Breaker 600Y 220/240 380/415 690 Number To Handle
Class Type 240 480 /347 250 500 ICU ICS ICU ICS ICU ICS of Poles Width Length Depth D1
N NDGB 65 35 18 30 18 65 65 40 40 12 6 2, 3 4.1 (105) 6.9 (175) 3.4 (81) 4.2(107)
H HDGB 100 65 18 30 18 100 75 70 70 12 6
L LDGB 200 100 18 30 18 200 150 100 75 12 6

Connectors for 75°C Wire


Ampere Wire No. of cables
Approx. Shipping Weight, lbs. (kg)
Construction Rating Range per connector Catalog Number Trip Unit Complete
Steel 30-150 #8–1/0 Cu 1 3TW1DG20b Poles Frame Thermal-Mag. Electronic Breaker
Aluminum 30-150 #6–3/0 Al/Cu 1 3TA1DG30
2, 3 3.7 (1.7) 2.2 (1.0) 2.6 (1.2) 5.9 (2.7)

7
Copper 30-150 #6–3/0 Cu 1 3TC1DG30b
Distribution Lugs

CIRCUIT BREAKERS
MOLDED CASE
30-150 #14–#2 Al/Cu (3pcs. Max) 3 3TA3DG02b
30-150 #14–#4 Cu, #14–#6 Al 6 3TA6DG04b
Compression Lugs
30-150 #14–2/0 kcmil Al/Cu – 2CLD20c
30-150 #14–2/0 kcmil Al/Cu – 3CLD20b
a Standard connector supplied with complete breakers.
b Kit consists of 3 terminal connectors.
c 2 Lugs for 2-pole breakers.
d Required for 100% rated DG breakers. Requires 90°C Cu cable sized at 75°C ampacity

DG Thermal-Magnetic, Instantaneous
Trip Adjustment Range
Instantaneous
Trip Unit Continuous Overcurrent Setting (Ii)
Amp Rating (In) Min. Max.
50 450 600
60 450 600
70 450 700
80 450 800
90 500 1000
100 500 1000
110 550 1100
125 625 1250
150 800 1600
Note: Each breaker has 6 trip settings in this range. External Accessories pages 7-195 through 7-207

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-165
VL Circuit Breakers
DG 150A Thermal-Magnetic Trip Unit Selection

Ii Type / Tipo CDT3

AMPS I n =150A
1120 1280 40? C
TM ~
960 1440

800 1600 TRIP UNIT/DISPARADOR 525 Cat. No. - CDT3B150

Model 525 Trip Unit

DG 150A Frame 2-Pole with Thermal-Magnetic Trip Unit

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER

Continuous N-Interrupting Class H-Interrupting Class L-Interrupting Class


Ampere Rating Catalog Number Catalog Number Catalog Number
50 NDK2B050L HDK2B050L LDK2B050L
60 NDK2B060L HDK2B060L LDK2B060L
70 NDK2B070L HDK2B070L LDK2B070L
80 NDK2B080L HDK2B080L LDK2B080L
90 NDK2B090L HDK2B090L LDK2B090L
100 NDK2B100L HDK2B100L LDK2B100L
110 NDK2B110L HDK2B110L LDK2B110L
125 NDK2B125L HDK2B125L LDK2B125L
150 NDK2B150L HDK2B150L LDK2B150L

DG 150A Frame 3-Pole with Thermal-Magnetic Trip Unit


COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER

Continuous N-Interrupting Class H-Interrupting Class L-Interrupting Class


Ampere Rating Catalog Number Catalog Number Catalog Number
50 NDK3B050L HDK3B050L LDK3B050L
60 NDK3B060L HDK3B060L LDK3B060L
70 NDK3B070L HDK3B070L LDK3B070L
7

80 NDK3B080L HDK3B080L LDK3B080L


90 NDK3B090L HDK3B090L LDK3B090L
100 NDK3B100L HDK3B100L LDK3B100L
MOLDED CASE
CIRCUIT BREAKERS

110 NDK3B110L HDK3B110L LDK3B110L


125 NDK3B125L HDK3B125L LDK3B125L
150 NDK3B150L HDK3B150L LDK3B150L

7-166 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
DG 150A Electronic Trip Units Selection

Model 555 Trip Units

DG 150A Frame 3-Pole Electronic Trip Unit a


COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER

Continuous N-Interrupting Class H-Interrupting Class L-Interrupting Class


Ampere Rating Catalog Number Catalog Number Catalog Number
ELECTRONIC LI TRIP
60 NDK3R060L HDK3R060L LDK3R060L
100 NDK3R100L HDK3R100L LDK3R100L
150 NDK3R150L HDK3R150L LDK3R150L
ELECTRONIC LSI TRIP
60 NDK3T060L HDK3T060L LDK3T060L
100 NDK3T100L HDK3T100L LDK3T100L
150 NDK3T150L HDK3T150L LDK3T150L
ELECTRONIC LSIG TRIP
60 NDK3V060L HDK3V060L LDK3V060L
100 NDK3V100L HDK3V100L LDK3V100L
150 NDK3V150L HDK3V150L LDK3V150L
ELECTRONIC LIG TRIP
60 NDK3W060L HDK3W060L LDK3W060L
100 NDK3W100L HDK3W100L LDK3W100L
150 NDK3W150L HDK3W150L LDK3W150L

7
CIRCUIT BREAKERS
MOLDED CASE
Model 586 Trip Unit
DG 150A Frame 3-Pole Electronic LCD Trip Unit a
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER

Continuous N-Interrupting Class H-Interrupting Class L-Interrupting Class


Ampere Rating Catalog Number Catalog Number Catalog Number
LCD ELECTRONIC LSI TRIP
60 NDK3A060L HDK3A060L LDK3A060L
100 NDK3A100L HDK3A100L LDK3A100L
150 NDK3A150L HDK3A150L LDK3A150L
LCD ELECTRONIC LSIG TRIP
60 NDK3G060L HDK3G060L LDK3G060L
100 NDK3G100L HDK3G100L LDK3G100L
150 NDK3G150L HDK3G150L LDK3G150L
LCD ELECTRONIC LSI TRIP + GF ALARM ONLY
60 NDK3K060L HDK3K060L LDK3K060L
100 NDK3K100L HDK3K100L LDK3K100L
150 NDK3K150L HDK3K150L LDK3K150L

a  ue to the location of the magnetic tripping solenoid, the


D
left accessory pocket is not available for accessories.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-167
VL Circuit Breakers
Internal Accessories for DG 150A and FG 250A Frames Selection

Auxiliary Switch and Alarm Switch Combination Kits


Description Mounting Pocketa Catalog Number
1 Alarm Switch
1A/Bc Left, Rightb ASKL1
Bases AMBL2 & AMBL3
2 Aux. Switches
1A + 1B Left, Right ASKL2
Bases AMBL1
2 Aux. + 1 Alarm Switch
1A + 1B, 1A/Bc Left, Rightb ASKL3
Bases AMBL2 & AMBL3

Auxiliary/Alarm Switch Mounting Base Only


Description Mounting Pocket Catalog Number
Up to 3 Auxiliary Switches Left, Right AMBL1
2 Aux. + 1 Alarm Switch Left Pocket Only AMBL2
2 Aux. + 1 Alarm Switch Right Pocket Only AMBL3

Auxiliary/Alarm Switch Only


Common to DG - PG Frames
Description Catalog Number
1 Normally Open Contact (1A) ASWPA
1 Normally Closed Contact (1B) ASWPB

Shunt Trips
Description Mounting Pocket Catalog Number
24 VDC STRLB24DC
48-60 VDC STRLC60DC
110-127 VDC STRLD125DC
220-250 VDC Right Pocket Only STRLE250DC
48-60 VAC STRLM60
110-127 VAC STRLN120
208-277 VAC STRLS277
380-600 VAC
7

STRLV600

Undervoltage Release
MOLDED CASE
CIRCUIT BREAKERS

Description Mounting Pocket Catalog Number


12 VDC UVRLA12DC
24 VDC UVRLB24DC
48 VDC UVRLC48DC UVRLN120
60 VDC UVRLG60DC
110-127 VDC UVRLD125DC
220-250 VDC UVRLE250DC
24 VAC Right Pocket Only UVRLL24
110-127 VAC UVRLN120
220-240 VAC UVRLR240
208 VAC UVRLP208
277 VAC UVRLS277
380-415 VAC UVRLT415
440-480 VAC UVRLU480

a  efer to the “Accessory Locations” chart on page 7-208 for guidelines and limitations about which pockets may be used for
R
accessory combinations.
b These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right.
c Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.
‘A’ refers to a normally open contact (open when the breaker contacts are open). External Accessories pages 7-195 through 7-207
‘B’ refers to a normally closed contact (closed when the breaker contacts are open).

7-168 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
FG 250A Frame, VL Series Selection/Dimensions

Ordering Information
Complete Assembled Breaker
A complete factory assembled FG breaker includes the frame, trip unit,
and standard line and load connectors, all factory installed and shipped as
a complete breaker. Assembled breakers are available only with standard
connectors.
For DC applications, use thermal magnetic trip unit only.
Breakers are suitable for reverse feed applications.
For special applications, refer to page 7-212.
Mounting hardware is included with each frame or complete breaker.
HACR rated.

Interrupting Ratings Dimensions, inches (mm)


RMS Symmetrical Amperes (KA) Number To Handle
UL 489 IEC 60947-2 of Poles Width Length Depth D1
Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)
Breaker 600Y/ 220/240 380/415 690 2, 3 4.1 (105) 6.9 (175) 3.4 (81) 4.2 (107)
Type 240 480 347 250 500 ICU ICS ICU ICS ICU ICS
NFG 65 35 18 30 18 65 65 40 40 12 6
HFG 100 65 18 30 18 100 75 70 70 12 6 Shipping Weight, lbs. (kg)
LFG 200 100 18 30 18 200 150 100 75 12 6 Trip Unit Complete
Poles Frame Thermal-Mag. Electronic Breaker
Connectors for 75°C Wire 2, 3 4.0 (1.8) 2.2 (1.0) 2.6 (1.2) 6.2 (2.8)
Ampere Wire No. of cables Catalog
Construction Rating Range per connector Number
Steel 50-250 #4–350 kcmil Cu 1 3TW1FG350
Aluminum 50-250 #4–350 kcmil Al/Cu 1 3TAW1FG350
Copper 50-250 #4–350 kcmil Cu 1 3TCW1FG350
Distribution Lugs
50-250 #12–2/0 Cu/Al 3 3TA3FG20
50-250 #14–#4 Cu/Al 6 3TA6FG04
 Standard connector supplied with complete breakers.

7
 Kitconsists of 3 terminal connectors.
 2 Lugs for 2-pole breakers.
 3 Lugs for 3-pole breakers.

CIRCUIT BREAKERS
MOLDED CASE
FG Thermal-Magnetic,
Instantaneous Trip
Adjustment Range
Instantaneous
Trip Unit Continuous Overcurrent Setting (Ii)
Amp Rating (In) Min. Max.
100 625 1250
110 800 1600
125 800 1600
150 800 1600
175 1000 2000
200 1000 2000
225 1250 2500
250 1250 2500
Note: Each breaker has 6 trip settings in this range.

External Accessories pages 7-195 through 7-207

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-169
VL Circuit Breakers
FG 250A Thermal-Magnetic Trip Unit Selection

Ii Type / Tipo CFT3

AMPS I n =250A
1750 2000 40? C
TM ~
1500 2250

1250 2500 TRIP UNIT/DISPARADOR 525 Cat. No. - CFT3B250

Model 525 Trip Unit

FG 250A Frame 2-Pole with Thermal-Magnetic Trip Unit


COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER

Continuous N-Interrupting Class H-Interrupting Class L-Interrupting Class


Ampere Rating Catalog Number Catalog Number Catalog Number
100 NFK2B100L HFK2B100L LFK2B100L
110 NFK2B110L HFK2B110L LFK2B110L
125 NFK2B125L HFK2B125L LFK2B125L
150 NFK2B150L HFK2B150L LFK2B150L
175 NFK2B175L HFK2B175L LFK2B175L
200 NFK2B200L HFK2B200L LFK2B200L
225 NFK2B225L HFK2B225L LFK2B225L
250 NFK2B250L HFK2B250L LFK2B250L

FG 250A Frame 3-Pole with Thermal-Magnetic Trip Unit

COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER

N-Interrupting Class H-Interrupting Class L-Interrupting Class


Continuous
Ampere Rating Catalog Number Catalog Number Catalog Number
100 NFK3B100L HFK3B100L LFK3B100L
110 NFK3B110L HFK3B110L LFK3B110L
125 NFK3B125L HFK3B125L LFK3B125L
150 NFK3B150L HFK3B150L LFK3B150L
7

175 NFK3B175L HFK3B175L LFK3B175L


200 NFK3B200L HFK3B200L LFK3B200L
NFK3B225L HFK3B225L LFK3B225L
MOLDED CASE
CIRCUIT BREAKERS

225
250 NFK3B250L HFK3B250L LFK3B250L
0

7-170 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
FG 250A Electronic Trip Units Selection

Model 555 Trip Units

FG 250A Frame 3-Pole Electronic Trip Unita


COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER

Continuous N-Interrupting Class H-Interrupting Class L-Interrupting Class


Ampere Rating Catalog Number Catalog Number Catalog Number
ELECTRONIC LI TRIP
100 NFK3R100L HFK3R100L LFK3R100L
150 NFK3R150L HFK3R150L LFK3R150L
250 NFK3R250L HFK3R250L LFK3R250L
ELECTRONIC LSI TRIP
100 NFK3T100L HFK3T100L LFK3T100L
150 NFK3T150L HFK3T150L LFK3T150L
250 NFK3T250L HFK3T250L LFK3T250L
ELECTRONIC LSIG TRIP
100 NFK3V100L HFK3V100L LFK3V100L
150 NFK3V150L HFK3V150L LFK3V150L
250 NFK3V250L HFK3V250L LFK3V250L
ELECTRONIC LIG TRIP
100 NFK3W100L HFK3W100L LFK3W100L
150 NFK3W150L HFK3W150L LFK3W150L
250 NFK3W250L HFK3W250L LFK3W250L

7
CIRCUIT BREAKERS
MOLDED CASE
Model 586 Trip Unit
FG 250A Frame 3-Pole Electronic LCD Trip Unita
COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER

Continuous N-Interrupting Class H-Interrupting Class L-Interrupting Class


Ampere Rating Catalog Number Catalog Number Catalog Number
LCD ELECTRONIC LSI TRIP
100 NFK3A100L HFK3A100L LFK3A100L
150 NFK3A150L HFK3A150L LFK3A150L
250 NFK3A250L HFK3A250L LFK3A250L
LCD ELECTRONIC LSIG TRIP
100 NFK3G100L HFK3G100L LFK3G100L
150 NFK3G150L HFK3G150L LFK3G150L
250 NFK3G250L HFK3G250L LFK3G250L
LCD ELECTRONIC LSI TRIP + GF ALARM ONLY
100 NFK3K100L HFK3K100L LFK3K100L
150 NFK3K150L HFK3K150L LFK3K150L
250 NFK3K250L HFK3K250L LFK3K250L

a  ue to the location of the magnetic tripping solenoid, the


D
left accessory pocket is not available for accessories.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-171
VL Circuit Breakers
Internal Accessories for DG 150A and FG 250A Frames Selection

Auxiliary Switch and Alarm Switch Combination Kits


Description Mounting Pocketa Catalog Number
1 Alarm Switch
1A/Bc Left, Rightb ASKL1
Bases AMBL2 & AMBL3
2 Aux. Switches
1A + 1B Left, Right ASKL2
Bases AMBL1
2 Aux. + 1 Alarm Switches
1A + 1B, 1A/Bc Left, Rightb ASKL3
Bases AMBL2 & AMBL3

Auxiliary/Alarm Switch Mounting Base Only


Description Mounting Pocket Catalog Number
Up to 3 Auxiliary Switches Left, Right AMBL1
2 Aux. + 1 Alarm Switch Left Pocket Only AMBL2
2 Aux. + 1 Alarm Switch Right Pocket Only AMBL3

Auxiliary/Alarm Switch Only


Common to DG - PG Frames
Description Catalog Number
1 Normally Open Contact (1A) ASWPA
1 Normally Closed Contact (1B) ASWPB

Shunt Trips
Description Mounting Pocket Catalog Number
24 VDC STRLB24DC
48-60 VDC STRLC60DC
110-127 VDC STRLD125DC
220-250 VDC Right Pocket Only STRLE250DC
48-60 VAC STRLM60
110-127 VAC STRLN120
208-277 VAC STRLS277
7

380-600 VAC STRLV600


MOLDED CASE
CIRCUIT BREAKERS

Undervoltage Release
Description Mounting Pocket Catalog Number
12 VDC UVRLA12DC
24 VDC UVRLB24DC
48 VDC UVRLC48DC UVRLN120
60 VDC UVRLG60DC
110-127 VDC UVRLD125DC
220-250 VDC UVRLE250DC
24 VAC Right Pocket Only UVRLL24
110-127 VAC UVRLN120
220-240 VAC UVRLR240
208 VAC UVRLP208
277 VAC UVRLS277
380-415 VAC UVRLT415
440-480 VAC UVRLU480

a Refer to the “Accessory Locations” chart on page 7-208 for guidelines and limitations about which pockets may be
used for accessory combinations.
b These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right.
c Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.
‘A’ refers to a normally open contact (open when the breaker contacts are open). External Accessories pages 7-195 through 7-207
‘B’ refers to a normally closed contact (closed when the breaker contacts are open).

7-172 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
JG 400A Frame, VL Series Selection/Dimensions

Ordering Information
Complete Assembled Breaker
A complete factory assembled JG breaker includes the frame, trip unit,
and standard line and load connectors, all factory installed and shipped
as a complete breaker. Assembled breakers are available only with
standard connectors.
For any other configuration, order the frame, trip unit, and terminals as
separate items.
For DC applications, use thermal magnetic trip unit only.
For reverse feed applications, select non-interchangeable trip breakers only.
For non-interchangeable trip breakers, change the third digit of the catalog
number to “X” for standard breakers.
For 100% rated breakers with a non-interchangeable trip unit, change the 3rd
character of the catalog number to ”Y“ (3-pole only).
For special applications, refer to page 7-212.
Mounting hardware is included with each frame or complete breaker. Dimensions, inches (mm)
HACR rated. Number To Handle
of Poles Width Length Depth D1

Interrupting Ratings 2, 3 5.5 (139) 11 (279) 4.2 (102) 5.4 (138)

RMS Symmetrical Amperes (KA)


UL 489 AIR (File E10848) IEC 60947-2 Shipping Weight, lbs. (kg)
Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)
Trip Unit Complete
Interrupting Breaker 220/240 380/415 690 Poles Frame Thermal-Mag. Electronic Breaker
Class Type 240 480 600 250 500 ICU ICS ICU ICS ICU ICS
2, 3 9.3 (4.2) 4.0 (1.8) 4.0 (1.8) 12.6 (5.7)
N NJGA 65 35 25 30 25 65 65 45 45 12 6
H HJGA 100 65 25 30 35 100 75 70 70 15 8
L LJGA 200 100 25 30 35 200 150 100 75 15 8

Connectors for 75°C Wire


Ampere Wire No. of cables
Construction Rating Range per connector Catalog Number
Steel 70-400 1/0–600 kcmil Cu 1 3TW1JG600b

7
Aluminum 70-400 3/0–250 kcmil Al/Cu 2 3TA2JG250ab
Aluminum 70-400 250–750 kcmil Al 1 3TA1JG750b
Aluminum 70-400 3/0–600 kcmil Cu 1 3TA1JG750b

CIRCUIT BREAKERS
MOLDED CASE
Copper 70-400 3/0–600 kcmil Cu 1 TC1JG750
Copper 70-400 3/0–250 kcmil Cu 2 TC2JG250
Distribution Lugs
70-400 #14–4 Cu 12 3TA12JG04b
70-400 #14–2/0 Al/Cu 6 3TA6JG20b
Compression Lugs
70-400 #6–350 kcmil — 3CLJ350b
70-400 250-600 kcmil — 3CLJ600b
a Standard construction supplied for each breaker.
b Kit consists of 3 terminal connectors.
c Required for 100% rated JG breakers. Requires 90°C Cu
cable sized at 75°C ampacity.

JG Thermal-Magnetic,
Instantaneous
Trip Adjustment Range
Instantaneous
Trip Unit Continuous Overcurrent Setting (Ii)
Amp Rating (In) Min. Max.
250 1250 2500
300 1500 3000
350 1750 3500
400 2000 4000
External Accessories pages 7-195 through 7-207
Note: Each breaker has 6 trip settings in this range.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-173
VL Circuit Breakers
JG 400A Thermal-Magnetic Trip Unit Selection

Model 525 Trip Unit


JG 400A Frame 2-Pole with Thermal-Magnetic Trip Unit
                           
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NJG2F400 HJG2F400 LJG2F400
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
250 NJG2B250L HJG2B250L LJG2B250L CJT2B250
300 NJG2B300L HJG2B300L LJG2B300L CJT2B300
350 NJG2B350L HJG2B350L LJG2B350L CJT2B350
400 NJG2B400L HJG2B400L LJG2B400L CJT2B400

JG 400A Frame 3-Pole with Thermal-Magnetic Trip Unit


                           
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NJG3F400 HJG3F400 LJG3F400
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
250 NJG3B250L HJG3B250L LJG3B250L CJT3B250
300 NJG3B300L HJG3B300L LJG3B300L CJT3B300
350 NJG3B350L HJG3B350L LJG3B350L CJT3B350
400 NJG3B400L HJG3B400L LJG3B400L CJT3B400

JJ 400A Frame 240V max., 2-pole with


Thermal-Magnetic Non-Interchangeable Trip Unit
7

N-Interrupting Class

Continuous Catalog Number


MOLDED CASE
CIRCUIT BREAKERS

Ampere Rating COMPLETE BREAKER


250 NJJ2B250
300 NJJ2B300
350 NJJ2B350
400 NJJ2B400

JJ 400A Frame 240V max., 3-pole with


Thermal-Magnetic Non-Interchangeable Trip Unit
                            N-Interrupting Class

Continuous Catalog Number


Ampere Rating COMPLETE BREAKER
250 NJJ3B250
300 NJJ3B300
350 NJJ3B350
400 NJJ3B400

 Terminal connectors must be ordered separately.


Breaker Type NJJA.

7-174 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
JG 400A Electronic Trip Units Selection

Model 555 Trip Units

JG 400A Frame 3-Pole Electronic Trip Unit


                   
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NJG3F400 HJG3F400 LJG3F400
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
ELECTRONIC LI TRIP
250 NJG3R250L HJG3R250L LJG3R250L CJT3R250
400 NJG3R400L HJG3R400L LJG3R400L CJT3R400
ELECTRONIC LSI TRIP
250 NJG3T250L HJG3T250L LJG3T250L CJT3T250
400 NJG3T400L HJG3T400L LJG3T400L CJT3T400
ELECTRONIC LSIG TRIP
250 NJG3V250L HJG3V250L LJG3V250L CJT3V250
400 NJG3V400L HJG3V400L LJG3V400L CJT3V400
ELECTRONIC LIG TRIP
250 NJG3W250L HJG3W250L LJG3W250L CJT3W250
400 NJG3W400L HJG3W400L LJG3W400L CJT3W400

7
CIRCUIT BREAKERS
MOLDED CASE
Model 586 Trip Unit

JG 400A Frame 3-Pole Electronic LCD Trip Unit


                   
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NJG3F400 HJG3F400 LJG3F400
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
LCD ELECTRONIC LSI TRIP
250 NJG3A250L HJG3A250L LJG3A250L CJT3A250
400 NJG3A400L HJG3A400L LJG3A400L CJT3A400
LCD ELECTRONIC LSIG TRIP
250 NJG3G250L HJG3G250L LJG3G250L CJT3G250
400 NJG3G400L HJG3G400L LJG3G400L CJT3G400
LCD ELECTRONIC LSI TRIP + GF ALARM ONLY
250 NJG3K250L HJG3K250L LJG3K250L CJT3K250
400 NJG3K400L HJG3K400L LJG3K400L CJT3K400

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-175
VL Circuit Breakers
Internal Accessories for JG 400A and LG 600A Frames Selection

Auxiliary Switch and Alarm Switch Combination Kits


Description Mounting Pocketa Catalog Number
1 Alarm Switch
1A/Bc Left, Rightb ASKL1
Bases AMBL2 & AMBL3
2 Aux. Switches
1A + 1B Left, Right ASKL2
Bases AMBL1
2 Aux. + 1 Alarm Switches
1A + 1B, 1A/B Left, Rightb ASKL3
Bases AMBL2 & AMBL3

Auxiliary/Alarm Switch Mounting Base Only


Description Mounting Pocket Catalog Number
Up to 3 Auxiliary Switches Left, Right AMBL1
2 Aux. + 1 Alarm Switch Left Pocket Only AMBL2
2 Aux. + 1 Alarm Switch Right Pocket Only AMBL3

Auxiliary/Alarm Switch Only


Common to DG - PG Frames
Description Catalog Number
1 Normally Open Contact (1A) ASWPA
1 Normally Closed Contact (1B) ASWPB

Shunt Trips
Description Mounting Pocket Catalog Number
24 VDC STRLB24DC
48-60 VDC STRLC60DC
110-127 VDC STRLD125DC
220-250 VDC Right Pocket Only STRLE250DC
48-60 VAC STRLM60
110-127 VAC STRLN120
208-277 VAC STRLS277
380-600 VAC STRLV600
7

Undervoltage Release
MOLDED CASE
CIRCUIT BREAKERS

Description Mounting Pocket Catalog Number


12 VDC UVRLA12DC
24 VDC UVRLB24DC
48 VDC UVRLC48DC
60 VDC UVRLG60DC
110-127 VDC UVRLD125DC UVRLN120
220-250 VDC UVRLE250DC
24 VAC Right Pocket Only UVRLL24
110-127 VAC UVRLN120
220-240 VAC UVRLR240
208 VAC UVRLP208
277 VAC UVRLS277
380-415 VAC UVRLT415
440-480 VAC UVRLU480

a Refer to the “Accessory Locations” chart on page 7-208 for guidelines and limitations about which
pockets may be used for accessory combinations.
b Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.
‘A’ refers to a normally open contact (open when the breaker contacts are open).
‘B’ refers to a normally closed contact (closed when the breaker contacts are open). External Accessories pages 7-195 through 7-207

7-176 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
LG 600A Frame, VL Series Selection/Dimensions

Ordering Information
Complete Assembled Breaker
A complete factory assembled LG breaker includes the frame, trip unit, and
standard line and load lugs, all factory installed and shipped as a complete
breaker. Assembled breakers are available only with standard connectors.
For DC applications, use thermal magnetic trip unit only.
Breakers are suitable for reverse feed applications.
For special applications, refer to page 7-212.
Mounting hardware is included with each breaker.
For 100% rated breakers, change the 3rd character of the catalog number to
“W”. Available on 400/500 Amp only (3-pole only).
HACR rated.

Interrupting Ratings
RMS Symmetrical Amperes (KA) Dimensions, inches (mm)
UL 489 IEC 60947-2 Number To Handle
Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) of Poles Width Length Depth D1
Interrupting Breaker 220/240 380/415 690
2, 3 5.5 (139) 11 (279) 4.2 (102) 5.4 (138)
Class Type 240 480 600 250 500 ICU ICS ICU ICS ICU ICS
Ext. 13.6
N NLGB 65 35 18 30 25 65 65 45 45 12 6
Shield (345.5)
H HLGB 100 65 18 30 35 100 75 70 70 15 8
L LLGB 200 100 18 30 35 200 150 100 75 15 8
 Special 600Vac 25kA thermal-magnetic version (Type HLGC) available, see page 7-178.

Shipping Weight, lbs. (kg)


Connectors for 75°C Wire Trip Unit Complete
Poles Frame Thermal-Mag. Electronic Breaker
Ampere Wire No. of cables
Construction Rating Range per connector Catalog Number 2, 3 17.4 (7.9) 3.5 (1.6) 4.2 (1.9) 20.9 (9.5)
Aluminum 150-600 #2–600 kcmil Al/Cu 2 (load side) 3TA2LG600LD
Aluminum 150-600 #2–600 kcmil Al/Cu 2 (line side) 3TA2LG600LN
Copper 150-600 #2–600 kcmil Cu 2 (load side) 3TC2LG600LD
Copper 150-600 #2–600 kcmil Cu 2 (line side) 3TC2LG600LN
Compression Lugs
150-600 #6–350 kcmil Al/Cu — 6CLL350
150-600 250-750 kcmil Al/Cu — 3CLL750

7
150-600 250-600 kcmil Al/Cu — 6CLL600
 Standard construction supplied for each breaker.

CIRCUIT BREAKERS
MOLDED CASE
 Kit consists of 3 terminal connectors.
 Kit consists of 6 lugs for Line or Load end.
 Required for 100% rated LG breakers. Requires 90°C Cu cable sized at 75°C ampacity.

LG Thermal-Magnetic,
Instantaneous
Trip Adjustment Range
Instantaneous
Trip Unit Continuous Overcurrent Setting (Ii)
Amp Rating (In) Min. Max.
400 2000 4000
500 2500 5000
600 2750 5500
Note: Each breaker has 6 trip settings.

External Accessories pages 7-195 through 7-207

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-177
VL Circuit Breakers
LG 600A Thermal-Magnetic Trip Unit Selection

Model 525 Trip Unit

LG 600A Frame 2-Pole with Thermal-Magnetic Trip Unit


N-Interrupting Class H-Interrupting Class L-Interrupting Class

Continuous Catalog Number Catalog Number Catalog Number


Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER
400 NLK2B400L HLK2B400L LLK2B400L
500 NLK2B500L HLK2B500L LLK2B500L
600 NLK2B600L HLK2B600L LLK2B600L

LG 600A Frame 3-Pole with Thermal-Magnetic Trip Unit


N-Interrupting Class H-Interrupting Class L-Interrupting Class

Continuous Catalog Number Catalog Number Catalog Number


Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER
400 NLK3B400L HLK3B400L LLK3B400L
500 NLK3B500L HLK3B500L LLK3B500L
600 NLK3B600L HLK3B600L LLK3B600L

Type HLGC 600A Frame 2-Pole with Thermal-Magnetic Trip Unit , 600Vac 25kA only
N-Interrupting Class H-Interrupting Class L-Interrupting Class
7

Continuous Catalog Number Catalog Number Catalog Number


Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER
MOLDED CASE
CIRCUIT BREAKERS

400 — HLV2B400L —
500 — HLV2B500L —
600 — HLV2B600L —

Type HLGC 600A Frame 3-Pole with Thermal-Magnetic Trip Unit , 600Vac 25kA only
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Continuous Catalog Number Catalog Number Catalog Number


Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER
400 — HLV3B400L —
500 — HLV3B500L —
600 — HLV3B600L —

 For
100% rated 400A or 500A versions, change the third  Consult sales office for availability.
character of the catalog number to “Z”.

7-178 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
LG 600A Electronic Trip Units Selection

Model 555 Trip Unit

LG 600A Frame 3-Pole Electronic Trip Unit


N-Interrupting Class H-Interrupting Class L-Interrupting Class
Catalog Number Catalog Number Catalog Number
Continuous
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER
ELECTRONIC LI TRIP
400 NLK3R400L HLK3R400L LLK3R400L
600 NLK3R600L HLK3R600L LLK3R600L
ELECTRONIC LSI TRIP
400 NLK3T400L HLK3T400L LLK3T400L
600 NLK3T600L HLK3T600L LLK3T600L
ELECTRONIC LSIG TRIP
400 NLK3V400L HLK3V400L LLK3V400L
600 NLK3V600L HLK3V600L LLK3V600L
ELECTRONIC LIG TRIP
400 NLK3W400L HLK3W400L LLK3W400L
600 NLK3W600L HLK3W600L LLK3W600L

7
CIRCUIT BREAKERS
MOLDED CASE
Model 586 Trip Unit

LG 600A Frame 3-Pole Electronic LCD Trip Unit


N-Interrupting Class H-Interrupting Class L-Interrupting Class
Catalog Number Catalog Number Catalog Number
Continuous
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER
ELECTRONIC LSI TRIP
400 NLK3A400L HLK3A400L LLK3A400L
600 NLK3A600L HLK3A600L LLK3A600L
ELECTRONIC LSIG TRIP
400 NLK3G400L HLK3G400L LLK3G400L
600 NLK3G600L HLK3G600L LLK3G600L
ELECTRONIC LSI TRIP + GF ALARM ONLY
400 NLK3K400L HLK3K400L LLK3K400L
600 NLK3K600L HLK3K600L LLK3K600L

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-179
VL Circuit Breakers
Internal Accessories for JG 400A and LG 600A Frames Selection

Auxiliary Switch and Alarm Switch Combination Kits


Description Mounting Pocketa Catalog Number
1 Alarm Switch
1A/Bc Left, Rightb ASKL1
Bases AMBL2 & AMBL3
2 Aux. Switches
1A + 1B Left, Right ASKL2
Bases AMBL1
2 Aux. + 1 Alarm Switches
1A + 1B, 1A/B Left, Rightb ASKL3
Bases AMBL2 & AMBL3

Auxiliary/Alarm Switch Mounting Base Only


Description Mounting Pocket Catalog Number
Up to 3 Auxiliary Switches Left, Right AMBL1
2 Aux. + 1 Alarm Switch Left Pocket Only AMBL2
2 Aux. + 1 Alarm Switch Right Pocket Only AMBL3

Auxiliary/Alarm Switch Only


Common to DG - PG Frames
Description Catalog Number
1 Normally Open Contact (1A) ASWPA
1 Normally Closed Contact (1B) ASWPB

Shunt Trips
Description Mounting Pocket Catalog Number
24 VDC STRLB24DC
48-60 VDC STRLC60DC
110-127 VDC STRLD125DC
220-250 VDC Right Pocket Only STRLE250DC
48-60 VAC STRLM60
110-127 VAC STRLN120
208-277 VAC STRLS277
380-600 VAC STRLV600
7

Undervoltage Release
MOLDED CASE
CIRCUIT BREAKERS

Description Mounting Pocket Catalog Number


12 VDC UVRLA12DC
24 VDC UVRLB24DC
48 VDC UVRLC48DC
60 VDC UVRLG60DC
110-127 VDC UVRLD125DC UVRLN120
220-250 VDC UVRLE250DC
24 VAC Right Pocket Only UVRLL24
110-127 VAC UVRLN120
220-240 VAC UVRLR240
208 VAC UVRLP208
277 VAC UVRLS277
380-415 VAC UVRLT415
440-480 VAC UVRLU480

a  efer to the “Accessory Locations” chart on page 7-208 for guidelines and limitations about which pock-
R
ets may be used for accessory combinations.
b Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time.
‘A’ refers to a normally open contact (open when the breaker contacts are open).
‘B’ refers to a normally closed contact (closed when the breaker contacts are open). External Accessories pages 7-195 through 7-207

7-180 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
MG 800A Frame, VL Series Selection/Dimensions

Ordering Information
Complete Assembled Breaker
A complete factory assembled MG breaker includes the frame, trip unit, and
standard line and load lugs, all factory installed and shipped as a complete
breaker. Assembled breakers are available only with standard
connectors.
For any other configuration, order the frame, trip unit, and terminals as
separate items.
For DC applications, use thermal magnetic trip unit only.
For reverse feed applications, select non-interchangeable trip breakers only. For
non-interchangeable trip breakers, change the third digit of the catalog number
to “X” for standard breakers.
For 100% rated breakers with a non-interchangeable trip unit, change the 3rd
character of the catalog number to ”Y“.
For special applications, refer to page 7-212.
Mounting hardware is included with each frame or complete breaker. Dimensions, inches (mm)
HACR rated. Number To Handle
of Poles Width Length Depth D1

Interrupting Ratings 2, 3 7.5 (190) 16 (406) 4.7 (119) 5.9 (151)

RMS Symmetrical Amperes (KA)


UL 489 IEC 60947-2
Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)
Shipping Weight, lbs. (kg)
220/240 380/415 690 Complete
Interrupting Breaker
Poles Frame Trip Unit Breaker
Class Type 240 480 600 250 500 ICU ICS ICU ICS ICU ICS
N NMG 65 35 25 22 35 65 65 50 50 20 10 2, 3 31.3 (14.2) 4.0 (1.8) 35.3 (16.0)
H HMG 100 65 35 25 50 100 75 70 70 30 15
L LMG 200 100 50 42 65 200 150 100 75 35 17

Connectors for 75°C Wire


Ampere Wire No. of cables
Construction Rating Range per connector Catalog Number
Aluminum 200-800A 1/0–500 kcmil Al/Cu 3 3TA3MG500b
Aluminum 200-800A 500-750 kcmil Al/Cu 2 3TA2MG750b

7
Copper 200-800A 1/0–500 kcmil Cu 3 TC3MG500e
Aluminum 200-800A #2–600 kcmil Al/Cu 3 3TA3MG600bd

CIRCUIT BREAKERS
MOLDED CASE
a Standard connector supplied with complete breakers.
b Kit consists of 3 terminal connectors.
c Consists of one terminal.
d Includes extended terminal cover.
e Required for 100% rated MG breakers. Requires 90°C Cu cable sized at 75°C ampacity.

MG Thermal-Magnetic,
Instantaneous
Trip Adjustment Range
Instantaneous
Trip Unit Continuous Overcurrent Setting (Ii)
Amp Rating (In) Min. Max.
600 3000 6000
700 3250 6500
800 3250 6500
Note: Each breaker has 6 trip settings.

External Accessories pages 7-195 through 7-207

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-181
VL Circuit Breakers
MG 800A Thermal-Magnetic Trip Unit Selection

Model 525 Trip Unit

MG 800A Frame 2-Pole with Thermal-Magnetic Trip Unit


                           
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NMG2F800 HMG2F800 LMG2F800
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
600 NMG2B600L HMG2B600L LMG2B600L CMT2B600
700 NMG2B700L HMG2B700L LMG2B700L CMT2B700
800 NMG2B800L HMG2B800L LMG2B800L CMT2B800

MG 800A Frame 3-Pole with Thermal-Magnetic Trip Unit


                           
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NMG3F800 HMG3F800 LMG3F800
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
600 NMG3B600L HMG3B600L LMG3B600L CMT3B600
700 NMG3B700L HMG3B700L LMG3B700L CMT3B700
800 NMG3B800L HMG3B800L LMG3B800L CMT3B800
7 MOLDED CASE
CIRCUIT BREAKERS

7-182 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
MG 800A Electronic Trip Units Selection

Model 555 Trip Units

MG 800A Frame 3-Pole Electronic Trip Unit


                   
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NMG3F800 HMG3F800 LMG3F800
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
ELECTRONIC LI TRIP
600 NMG3R600L HMG3R600L LMG3R600L CMT3R600
800 NMG3R800L HMG3R800L LMG3R800L CMT3R800
ELECTRONIC LSI TRIP
600 NMG3T600L HMG3T600L LMG3T600L CMT3T600
800 NMG3T800L HMG3T800L LMG3T800L CMT3T800
ELECTRONIC LSIG TRIP
600 NMG3V600L HMG3V600L LMG3V600L CMT3V600
800 NMG3V800L HMG3V800L LMG3V800L CMT3V800
ELECTRONIC LIG TRIP
600 NMG3W600L HMG3W600L LMG3W600L CMT3W600
800 NMG3W800L HMG3W800L LMG3W800L CMT3W800

Model 586 Trip Unit

7
MG 800A Frame 3-Pole Electronic LCD Trip Unit

CIRCUIT BREAKERS
MOLDED CASE
                   
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NMG3F800 HMG3F800 LMG3F800
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
LCD ELECTRONIC LSI TRIP
600 NMG3A600L HMG3A600L LMG3A600L CMT3A600
800 NMG3A800L HMG3A800L LMG3A800L CMT3A800
LCD ELECTRONIC LSIG TRIP
600 NMG3G600L HMG3G600L LMG3G600L CMT3G600
800 NMG3G800L HMG3G800L LMG3G800L CMT3G800
LCD ELECTRONIC LSI TRIP + GF ALARM ONLY
600 NMG3K600L HMG3K600L LMG3K600L CMT3K600
800 NMG3K800L HMG3K800L LMG3K800L CMT3K800

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-183
VL Circuit Breakers
Internal Accessories for MG 800A, NG 1200A and PG 1600A Frames Selection

Auxiliary Switch and Alarm Switch Combination Kits


Description Mounting Pocketa Catalog Number
2 Aux. + 2 Alarm Switches
2A + 2B Left Pocket Only ASKP3
Bases AMBP2
4 Aux. Switches
2A + 2B Left, Right ASKP4 x4
Bases AMBP1

Auxiliary/Alarm Switch Mounting Base Only


Description Mounting Pocket Catalog Number
Up to 4 Auxiliary Switches Left, Right AMBP1
2 Aux. + 2 Alarm Switches Left Pocket Only AMBP2

Auxiliary/Alarm Switch Only


Common to DG - PG Frames
x4
Description Catalog Number
1 Normally Open Contact (1A) ASWPA
1 Normally Closed Contact (1B) ASWPB

Shunt Trips
Description Mounting Pocket Catalog Number
24 VDC STRPB24DC
48-60 VDC STRPC60DC
110-127 VDC STRPD125DC
220-250 VDC Right Pocket Only STRPE250DC
48-60 VAC STRPM60 AMBP2
110-127 VAC STRPN120
208-277 VAC STRPS277
380-600 VAC STRPV600

Undervoltage Release
Description Mounting Pocket Catalog Number
12 VDC UVRPA12DC
24 VDC
7

UVRPB24DC
48 VDC UVRPC48DC
60 VDC UVRPG60DC
MOLDED CASE
CIRCUIT BREAKERS

110-127 VDC UVRPD125DC


220-250 VDC UVRPE250DC
110-127 VAC Right Pocket Only UVRPN120
220-240 VAC UVRPR240
208 VAC UVRPP208
277 VAC UVRPS277
380-415 VAC UVRPT415
440-480 VAC UVRPU480
a Refer to the “Accessory Locations” chart on page 7-208 for guidelines and limitations about which pockets
may be used for accessory combinations.
STRPN120
‘A’ refers to a normally open contact (open when the breaker contacts are open).
‘B’ refers to a normally closed contact (closed when the breaker contacts are open).

UVRPN120

External Accessories pages 7-195 through 7-207

7-184 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
NG 1200A Frame, VL Series Selection/Dimensions

Ordering Information
Complete Assembled Breaker with Lugs
A complete factory assembled NG breaker includes the frame, trip unit,
and standard line and load lugs, all factory installed and shipped as a complete
breaker. Assembled breakers are available only with standard connectors.
For any other configuration, order the frame, trip unit, and terminals as
separate items.
For DC applications, use thermal magnetic trip unit only.
For reverse feed applications, select non-interchangeable trip breakers only. For
non-interchangeable trip breakers, change the third digit of the catalog number
to “X” for standard breakers.
For 100% rated breakers with a non-interchangeable trip unit, change the 3rd
character of the catalog number to ”Y“.
For special applications, refer to page 7-212.
Mounting hardware is included with each frame or complete breaker.
A Toggle Handle Extension is included with each frame or complete breaker. Dimensions, inches (mm)
HACR rated. Number To Handle
of Poles W L D D1
2, 3 9 (229) 16 (406) 6 (152) 8.1 (207)
Interrupting Ratings
RMS Symmetrical Amperes (KA)
UL 489 IEC 60947-2 Shipping Weight, lbs. (kg)
Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz)
Complete
Interrupting Breaker 220/240 380/415 690 Poles Frame Trip Unit Breaker
Class Type 240 480 600 250 500 ICU ICS ICU ICS ICU ICS 2, 3 46.3 (21.0) 8.8 (4.0) 55.1 (25.0)
N NNG 65 35 25 22 35 65 35 50 25 20 10
H HNG 100 65 35 25 50 100 50 70 35 30 15
L LNG 200 100 65 42 65 200 100 100 50 35 17

Connectors for 75°C Wire


Ampere Wire No. of cables
Construction Rating Range per connector Catalog Number
Aluminum 300-1200A 1/0–500 kcmil Al/Cu 4 3TA4NG500cd

7
Aluminum 300-1200A 500-750 kcmil Al/Cu 3 3TA3NG750d
Copper 300-1200A 1/0–500 kcmil Cu 4 3TC4NG500bd
Aluminum 300-1200A 1/0–500 kcmil Al/Cu 4 3TA4NG500Hbd

CIRCUIT BREAKERS
MOLDED CASE
Compression Lugs
300-1200A 1/0-500 kcmil Al/Cu — 12CLN500
a Total of 12 connectors (4 per phase Line or Load).
b For 100% rated NG breakers. Requires 90°C Cu cable sized at 75°C ampacity.
c Standard connector provided with complete breakers.
d Kit consists of 3 terminal connectors.

NG Thermal-Magnetic,
Instantaneous
Trip Adjustment Range
Instantaneous
Trip Unit Continuous Overcurrent Setting (Ii)
Amp Rating (In) Min. Max.
800 4000 8000
900 5000 10000
1000 5000 10000
1200 7000 12000
Note: Each breaker has 6 trip settings.

External Accessories pages 7-195 through 7-207

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-185
VL Circuit Breakers
NG 1200A Thermal-Magnetic Trip Unit Selection

Ii I n = 1200A Ii Ii
AMPS AMPS AMPS
40 C
9000 10000 9000 10000 9000 10000

8000
TM ~ 8000 8000
11000 11000 11000

7000 12000 7000 12000 7000 12000


Trip Unit/Disparador 525 Amps Amps

Model 525 Trip Unit

NG 1200A Frame 2-Pole with Thermal-Magnetic Trip Unit


                           
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NNG2F120 HNG2F120 LNG2F120
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
800 NNG2B800L HNG2B800L LNG2B800L CNT2B800
900 NNG2B900L HNG2B900L LNG2B900L CNT2B900
1000 NNG2B100L HNG2B100L LNG2B100L CNT2B100
1200 NNG2B120L HNG2B120L LNG2B120L CNT2B120

NG 1200A Frame 3-Pole with Thermal-Magnetic Trip Unit


                           
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NNG3F120 HNG3F120 LNG3F120
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
800 NNG3B800L HNG3B800L LNG3B800L CNT3B800
900 NNG3B900L HNG3B900L LNG3B900L CNT3B900
1000 NNG3B100L HNG3B100L LNG3B100L CNT3B100
1200 NNG3B120L HNG3B120L LNG3B120L CNT3B120
7 MOLDED CASE
CIRCUIT BREAKERS

7-186 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
NG 1200A Electronic Trip Units Selection

Model 555 Trip Units

NG 1200A Frame 3-Pole Electronic Trip Unit


                   
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NNG3F120 HNG3F120 LNG3F120
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
ELECTRONIC LI TRIP
800 NNG3R800L HNG3R800L LNG3R800L CNT3R800
1000 NNG3R100L HNG3R100L LNG3R100L CNT3R100
1200 NNG3R120L HNG3R120L LNG3R120L CNT3R120
ELECTRONIC LSI TRIP
800 NNG3T800L HNG3T800L LNG3T800L CNT3T800
1000 NNG3T100L HNG3T100L LNG3T100L CNT3T100
1200 NNG3T120L HNG3T120L LNG3T120L CNT3T120
ELECTRONIC LSIG TRIP
800 NNG3V800L HNG3V800L LNG3V800L CNT3V800
1000 NNG3V100L HNG3V100L LNG3V100L CNT3V100
1200 NNG3V120L HNG3V120L LNG3V120L CNT3V120
ELECTRONIC LIG TRIP
800 NNG3W800L HNG3W800L LNG3W800L CNT3W800
1000 NNG3W100L HNG3W100L LNG3W100L CNT3W100
1200 NNG3W120L HNG3W120L LNG3W120L CNT3W120

7
CIRCUIT BREAKERS
MOLDED CASE
Model 586 Trip Unit

NG 1200A Frame 3-Pole Electronic LCD Trip Unit


                   
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NNG3F120 HNG3F120 LNG3F120
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
LCD ELECTRONIC LSI TRIP
800 NNG3A800L HNG3A800L LNG3A800L CNT3A800
1000 NNG3A100L HNG3A100L LNG3A100L CNT3A100
1200 NNG3A120L HNG3A120L LNG3A120L CNT3A120
LCD ELECTRONIC LSIG TRIP
800 NNG3G800L HNG3G800L LNG3G800L CNT3G800
1000 NNG3G100L HNG3G100L LNG3G100L CNT3G100
1200 NNG3G120L HNG3G120L LNG3G120L CNT3G120
LCD ELECTRONIC LSI TRIP + GF ALARM ONLY
800 NNG3K800L HNG3K800L LNG3K800L CNT3K800
1000 NNG3K100L HNG3K100L LNG3K100L CNT3K100
1200 NNG3K120L HNG3K120L LNG3K120L CNT3K120

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-187
VL Circuit Breakers
Internal Accessories for MG 800A, NG 1200A, and PG 1600A Frames Selection

Auxiliary Switch and Alarm Switch Combination Kits


Description Mounting Pocketa Catalog Number
2 Aux. + 2 Alarm Switches
2A + 2B Left Pocket Only ASKP3
Base AMBP2
4 Aux. Switches
2A + 2B Left, Right ASKP4
Base AMBP1 x4

Auxiliary/Alarm Switch Mounting Base Only


Description Mounting Pocketa Catalog Number
Up to 4 Auxiliary Switches Left, Right AMBP1
2 Aux. + 2 Alarm Switches Left Pocket Only AMBP2

Auxiliary/Alarm Switch Only


Common to DG-PG Frames
Description Catalog Number
x4
1 Normally Open Contact (1A) ASWPA
1 Normally Closed Contact (1B) ASWPB

Shunt Trips
Description Mounting Pocket Catalog Number
24 VDC STRPB24DC
48-60 VDC STRPC60DC
110-127 VDC STRPD125DC
220-250 VDC Right Pocket Only STRPE250DC
48-60 VAC STRPM60
AMBP2
110-127 VAC STRPN120
208-277 VAC STRPS277
380-600 VAC STRPV600

Undervoltage Release
Description Mounting Pocket Catalog Number
12 VDC UVRPA12DC
7

24 VDC UVRPB24DC
48 VDC UVRPC48DC
MOLDED CASE
CIRCUIT BREAKERS

60 VDC UVRPG60DC
110-127 VDC UVRPD125DC
220-250 VDC UVRPE250DC
110-127 VAC Right Pocket Only UVRPN120
220-240 VAC UVRPR240
208 VAC UVRPP208
277 VAC UVRPS277
380-415 VAC UVRPT415
440-480 VAC UVRPU480 STRPN120
a Refer to the “Accessory Locations” chart on page 7-208 for guidelines and limitations about which
pockets may be used for accessory combinations.
‘A’ refers to a normally open contact (open when the breaker contacts are open).
‘B’ refers to a normally closed contact (closed when the breaker contacts are open).

UVRPN120

External Accessories pages 7-195 through 7-207

7-188 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
PG 1600A Frame, VL Series & Thermal-Magnetic Trip Unit Selection/Dimensions

Ordering Information
A complete factory assembled PG breaker includes the frame and trip unit only.
The connectors must be ordered as separate items.
PG thermal-magnetic breakers sold as non-interchangeable only.
For any other configuration, order the frame, trip unit, and connectors as
separate items.
Connectors require a Breaker Lug Mounting Assembly or Breaker Mounting
Base and must be ordered as a seperate item.
For DC applications, use Thermal magnetic trip unit only.
For reverse feed applications select non-interchangeable trip breakers only.
Change the third digit of the catalog number to “X” for non-interchangeable trip
breakers.
For 100% rated breakers with a non-interchangeable trip unit, change the 3rd
character of the catalog number to ”Y“.
For special applications, refer to page 7-212.
Mounting hardware is included with each frame or complete breaker. Dimensions, inches (mm)
A Toggle Handle Extension is included with each frame or complete breaker. Number To Handle
of Poles W L D D1
2, 3 9 (229) 16 (406) 6 (152) 8.1 (207)
Interrupting Ratings
RMS Symmetrical Amperes (KA)
UL 489 IEC 60947-2 (ETU only) Shipping Weight, lbs. (kg)
Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) Complete
220/240 380/415 690 Poles Frame Trip Unit Breaker
Interrupting Breaker
Class Type 240 480 600 250 500 ICU ICS ICU ICS ICU ICS 2, 3 60.2 (27.3) 8.8 (4.0) 69.0 (31.3)
N NPG 65 35 25 22 35 65 35 50 25 20 10
H HPG 100 65 35 25 50 100 50 70 35 30 15
L LPG 200 100 65 42 65 200 100 100 50 35 17 PG Thermal-Magnetic,
Instantaneous
Connectors for 75°C Wire Trip Adjustment Range
Ampere Wire No. of cables Instantaneous
Construction Rating Range per phase Catalog Number Trip Unit Continuous Overcurrent Setting (Ii)
Amp Rating (In) Min. Max.

7
Aluminum 1200-1600A 1/0–750 kcmil Al/Cu 6 3TA6PG750ac
Aluminum 1200-1600A 300–600 kcmil Al/Cu 5 TA5P600bd 1200 7000 12000
Aluminum 1200-1600A 600–750 kcmil Al/Cu 4 TA4P750bd
1400 7000 12000

CIRCUIT BREAKERS
MOLDED CASE
Aluminum 1200-1600A 300–600 kcmil Al/Cu 6 TA6R600bd
Copper 1200-1600A 300–600 kcmil Cu 5 TC5R600bde 1600 7000 12000
Note: Each breaker has 6 trip settings in this range.

Mounting Arrangement
Ii I n = 1600A Ii Ii

Description Catalog Number 9000


AMPS

10000
40º C
9000
AMPS

10000 9000
AMPS

10000
TM ~

Lug Mounting Assembly LMAP1600


8000 11000 8000 11000 8000 11000

7000 12000 7000 12000 7000 12000


Trip Unit/Disparador 525 Amps Amps

Breaker Mounting Base (Front Connect) MBPG1600


Breaker Mounting Base (Rear Connect) MBPG1601
Model 525 Trip Unit

PG 1600A Frame 3-Pole with Thermal-Magnetic Trip Unit


N-Interrupting Class H-Interrupting Class L-Interrupting Class

Continuous Catalog Number Catalog Number Catalog Number
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER
1200 NPX3B120 HPX3B120 LPX3B120
1400 NPX3B140 HPX3B140 LPX3B140
1600 NPX3B160 HPX3B160 LPX3B160

a Requires Lug Mounting Assembly LMAP1600. d Consists of 1 connector.


b Requires Breaker Mounting Base MBPG1600 Kit or e Required for 100% rated PG breakers. Requires 90°C cable
MBPG1601. sized at 75°C ampacity. External Accessories pages 7-195 through 7-207
c Consists of 3 connectors.  IEC 60947-2: ONLY applies to Electronic Trip Units (ETUs).

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-189
VL Circuit Breakers
PG 1600A Electronic Trip Units Selection

Model 555 Trip Unit

PG 1600A Frame 3-Pole Electronic Trip Unit


                   
N-Interrupting Class H-Interrupting Class L-Interrupting Class

Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NPG3F160 HPG3F160 LPG3F160
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
ELECTRONIC LI TRIP
1200 NPG3R120 HPG3R120 LPG3R120 CPT3R120
1600 NPG3R160 HPG3R160 LPG3R160 CPT3R160
ELECTRONIC LSI TRIP
1200 NPG3T120 HPG3T120 LPG3T120 CPT3T120
1600 NPG3T160 HPG3T160 LPG3T160 CPT3T160
ELECTRONIC LSIG TRIP
1200 NPG3V120 HPG3V120 LPG3V120 CPT3V120
1600 NPG3V160 HPG3V160 LPG3V160 CPT3V160
ELECTRONIC LIG TRIP
1200 NPG3W120 HPG3W120 LPG3W120 CPT3W120
1600 NPG3W160 HPG3W160 LPG3W160 CPT3W160

Model 586 Trip Unit

PG 1600A Frame 3-Pole Electronic LCD Trip Unit


7

                   
N-Interrupting Class H-Interrupting Class L-Interrupting Class
MOLDED CASE
CIRCUIT BREAKERS


Catalog Number Catalog Number Catalog Number Catalog Number
FRAME ONLY
Continuous NPG3F160 HPG3F160 LPG3F160
Ampere Rating COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER TRIP UNIT ONLY
LCD ELECTRONIC LSI TRIP
1200 NPG3A120 HPG3A120 LPG3A120 CPT3A120
1600 NPG3A160 HPG3A160 LPG3A160 CPT3A160
LCD ELECTRONIC LSIG TRIP
1200 NPG3G120 HPG3G120 LPG3G120 CPT3G120
1600 NPG3G160 HPG3G160 LPG3G160 CPT3G160
LCD ELECTRONIC LSI TRIP + GF ALARM ONLY
1200 NPG3K120 HPG3K120 LPG3K120 CPT3K120
1600 NPG3K160 HPG3K160 LPG3K160 CPT3K160

7-190 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
Internal Accessories for MG 800A, NG 1200A, and PG 1600A Frames Selection

Auxiliary Switch and Alarm Switch Combination Kits


Description Mounting Pocketa Catalog Number
2 Aux. + 2 Alarm Switches
2A + 2B Left Pocket Only ASKP3
Base AMBP2
4 Aux. Switches
2A + 2B Left, Right ASKP4
Base AMBP1 x4

Auxiliary/Alarm Switch Mounting Base Only


Description Mounting Pocketa Catalog Number
Up to 4 Auxiliary Switches Left, Right AMBP1
2 Aux. + 2 Alarm Switches Left Pocket Only AMBP2

Auxiliary/Alarm Switch Only


Common to DG-PG Frames
Description Catalog Number x4
1 Normally Open Contact (1A) ASWPA
1 Normally Closed Contact (1B) ASWPB

Shunt Trips
Description Mounting Pocket Catalog Number
24 VDC STRPB24DC
48-60 VDC STRPC60DC
110-127 VDC STRPD125DC
220-250 VDC Right Pocket Only STRPE250DC
AMBP2
48-60 VAC STRPM60
110-127 VAC STRPN120
208-277 VAC STRPS277
380-600 VAC STRPV600

Undervoltage Release
Description Mounting Pocket Catalog Number

7
12 VDC UVRPA12DC
24 VDC UVRPB24DC

CIRCUIT BREAKERS
MOLDED CASE
48 VDC UVRPC48DC
60 VDC UVRPG60DC
110-127 VDC UVRPD125DC
220-250 VDC UVRPE250DC
110-127 VAC Right Pocket Only UVRPN120
220-240 VAC UVRPR240
208 VAC UVRPP208
277 VAC UVRPS277
380-415 VAC UVRPT415 STRPN120
440-480 VAC UVRPU480

a Refer to the “Accessory Locations” chart on page 7-208 for guidelines and limitations about which
pockets may be used for accessory combinations.
‘A’ refers to a normally open contact (open when the breaker contacts are open).
‘B’ refers to a normally closed contact (closed when the breaker contacts are open).

UVRPN120

External Accessories pages 7-195 through 7-207

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-191
VL Circuit Breakers
Molded Case Switch Selection

General switch has a fixed instantaneous self- the molded case switch. Also, the
Typically a molded case switch is used protecting trip element which may short-circuit current rating of the
when a compact load-break switch is open the switch under high fault condi- switch is limited to the interrupting rat-
needed for disconnect purposes. The tions. ing of the upstream protective device
VL line of molded case switches from or the ratings in the table below,
Application Note whichever is less.
Siemens is made of the same materi-
als and components as the VL circuit Overcurrent protection must be provid-
breakers but do not provide overcur- ed by an appropriate overcurrent pro-
rent protection. Each molded case tective device located upstream from

Ordering Information
Each type VL molded case switch accepts the same terminals and accessories as the equivalent VL circuit breakers.
All type VL molded case switches are suitable for reverse feed applications.
Mounting hardware and standard line and load terminals are included on ratings through 250A. For 400 – 1600A ratings,
order the lugs separately.
All ratings are UL listed and CSA certified.

Molded Case Switch


Maximum 2-Pole 3-Pole Short-Circuit Current Rating Self Protective
Ampere Instantaneous
Rating / Frame Catalog Number Catalog Number 240V 480V 600V Override
150A / DG HDR2S150 HDR3S150 100k 65k 20k 2,500A
250A / FG HFR2S250 HFR3S250 100k 65k 20k 3,500A
400A / JG HJS2S400 HJS3S400 100k 65k 25k 4,400A
600A / LG HLR2S600 HLR3S600 100k 65k 18k 5,500A
800A / MG HMS2S800 HMS3S800 100k 65k 35k 6,500A
1200A / NG HNS2S120 HNS3S120 100k 65k 35k 12,000A
1600A / PG — HPS3S160 100k 65k 35k 14,000A

Maximum 3-Pole Short-Circuit Current Rating Self Protective


Ampere Instantaneous
Rating / Frame Catalog Number 240V 480V 600V Override
7

250A / FG LFR3S250 200k 100k 25k 3,500A


MOLDED CASE
CIRCUIT BREAKERS

400A / JG LJS3S400 200k 100k 25k 4,400A


600A / LG LLR3S600 200k 100k 18k 5,500A
800A / MG LMS3S800 200k 100k 65k 6,500A
1200A / NG LNS3S120 200k 100k 65k 12,000A
1600A / PG LPS3S160 200k 100k 65k 14,000A

The Short-Circuit Current Rating is the maximum available


current of the circuit where the switch is used, when protect-
ed by an appropriate overcurrent protective device.

7-192 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
VL Circuit Breakers
Motor Circuit Protectors Selection

General
Protection of Motor Circuits  
Molded case circuit breakers are used in motor circuits as a disconnecting means and for short-circuit protection. They should be
used in conjunction with motor-running, over-current protection devices, and should permit the motor to start without nuisance trip-
ping from motor-inrush current. The circuit breaker should have a continuous current rating of not less than 115% of the motor full-
load current.
The recommended motor circuit protectors listed have continuous-current ratings of at least 115% of motor full-load currents. The
trip setting positions are approximately 11 times motor full-load current. The suggested trip settings may need to be adjusted
upward to no higher than 1300% of full-load current for non-design E type motors, and no greater than 1700% of full-load current
for design E motors, to allow for motor startup due to in-rush current.

Breaker Mounted Immediately Ahead of Motor Starter


Siemens motor circuit protectors are recommended for use in combination motor starters to provide selective short-circuit protec-
tion for the motor branch circuit. The adjustable instantaneous trip feature of the Siemens motor circuit protector provides for a trip
setting slightly above the peak motor in-rush current. With this setting, no delay is introduced in opening the circuit when a fault
occurs. This circuit breaker has no time-delay trip element. Therefore it must be used in conjunction with, and immediately ahead
of, the motor-running overcurrent protection device.

Important: The information below does not apply to all motor applications: it is recommended that the user refer to the National
Electrical Code (NEC) for specific needs.

Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter)


3-Phase Induction Type Motors (Siemens motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters)

Motor Full Trip Motor Full Trip


Load Amperes Setting (A) Catalog Number a Load Amperes Setting (A) Catalog Number a
35-50 450 96-139 1250
42-60 540 115-167 1500
48-70 630 HDP3L150L 135-194 1750 HJM3L400
55-80 720 154-222 2000
62-90 810 173-250 2250
69-100 900 192-278 2500
58-83 750 154-222 2000
69-100 900 185-267 2400
81-117 1050 HDP3M150L 215-311 2800 HJM3M400

7
92-133 1200 246-356 3200
104-150 1350 277-400 3600
115-150b 1500 308-400b 4000

CIRCUIT BREAKERS
MOLDED CASE
96-139 1250 154-222 2000
115-150b 1500 185-267 2400
135-150b 1750 HDP3H150L 215-311 2800 HLM3J600
135-150b 2000 246-356 3200
135-150b 2250 277-400 3600
135-150b 2500 308-444 4000
46-67 600 212-306 2750
55-80 720 254-367 3300
65-93 840 HFP3L250L 296-428 3850 HLM3Y600
74-107 960 338-489 4400
83-120 1080 381-550 4950
92-133 1200 423-600 5500
77-111 1000 250-361 3250
92-133 1200 292-422 3800
108-156 1400 HFP3M250L 335-483 4350 HMM3M800
123-178 1600 385-556 5000
138-200 1800 442-638 5740
154-222 2000 500-722 6500
135-194 1750 385-556 5000
162-210 2100 462-667 6000
188-220 2450 HFP3H250L 538-778 7000 HNM3M120
215-241 2800 615-889 8000
242-250b 3150 692-1000 9000
242-250b 3500 769-1111 10,000

a M
 otor circuit protectors rated 150A and 250A are supplied with line and load lugs b T
 hese settings are provided for starting currents greater than 11X but not to exceed
installed. If lugs are required on 400A to 1200A motor circuit breakers, order required 17X. Full Load Amps ( FLA ) not to exceed ampere rating of MCP.
lugs separately.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-193
Revised on 10/31/18

VL Circuit Breakers
600 Volt DC Circuit Breakers Selection

General the table. This family of circuit breakers interruption level, it is necessary to
Siemens UL Listed non-interchangeable is rated from 100 to 1600 Amperes. connect the terminals of the 3 pole
trip DC Thermal/magnetic Molded Case Types HFGD through HPGD circuit break- circuit breaker in a series configuration
Circuit Breakers shown below are for use ers are provided with an adjustable as shown in the diagram below.
in grounded & ungrounded general DC magnetic over-current function located Types HFGD through HPGD use the
circuits and ungrounded battery supply on the face of the circuit breaker. same internal and external accessories
circuits of UPS systems. These breakers Contact Siemens for specific magnetic as the standard FG through PG frames
are rated at 600Vdc closed circuit and over-current values. and associated types. Consult the
feature rated interruption levels from To properly use these UL Listed circuit individual frame section for accessory
42,000 to 65,000 amperes as indicated in breakers at 600Vdc and the indicated information.

Catalog Short-Circuit
Continuous Number Current Rating + –
Frame Type Ampere Rating (3-pole)a 600VDCb
100 HFC3B100 42K
150 HFC3B150 42K
FG HFGD 175 HFC3B175 42K
200 HFC3B200 42K
250 HFC3B250 42K
250 HJC3B250 65K
300 HJC3B300 65K
JG HJGD
350 HJC3B350 65K
LOAD
400 HJC3B400 65K
400 HLC3B400 65K
LG HLGD 500 HLC3B500 65K
600 HLC3B600 65K
600 HMC3B600 65K
MG HMGD 700 HMC3B700 65K
800 HMC3B800 65K
800 HNC3B800 65K
7

900 HNC3B900 65K


NG HNGD
1000 HNC3B100 65K
MOLDED CASE
CIRCUIT BREAKERS

1200 HNC3B120 65K


1200 HPC3B120 65K
PG HPGD 1400 HPC3B140 65K
1600 HPC3B160 65K

a T
 erminal connectors must be ordered separately; see page 7-202.
b S
 tandard VL breakers DG - PG feature DC ratings up to 500V for ungrounded UPS
applications. Consult the individual frame section for more information.

7-194 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


External Accessories
Selection

7
CIRCUIT BREAKERS
MOLDED CASE

1 Base for Plug-In or Draw-Out 9 Cover Frame for Door Cutout 17 Thermal Magnetic Trip Unit (525)
2 Interphase Barriers 10 Stored Energy Operator 18 Electronic Trip Unit (555)
3 Rear Terminals – Flat and Round 11 Rotary Handle Operator 19 Elec. Trip Unit with LCD (586)
4 Bus Extensions 12 Variable Depth Rotary Operator 20 Communication Module with ZSI
5 Terminal Connectors 13 Max Flex Operator 21 Electronic Trip Unit Tester and
6 Plug-In Terminal Blades 14 Circuit Breaker LCD Power Supply
7 Extended Terminal Shield 15 Shunt Trip or Undervoltage Releases
8 Standard Terminal Shield 16 Auxiliary/Alarm Switches

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-195


External Accessories
Operating Mechanisms 

For DG to FG Frame For JG to LG Frame


150 to 250 A 400 A to 600 A
RHFF

Description Catalog Number Catalog Number
Through-Door Rotary Handle Operator Kit
Fixed depth and the handle is mounted
directly on the circuit breaker.
Lockable knob (for up to 3 padlocks).
NEMA 1, 12 RHFF RHFL
Red Handle Version
with red knob, yellow indicator plate
NEMA 1, 12 RHFFEM RHFLEM
Door-Mounted Rotary Handle Operator Kit
Variable depth, door mounted handle.
Includes knob with masking frame,
RHVF12 indicator plate, detachable door coupling,
12” shaft, and breaker mounted rotary
operator. Lockable knob (for up to 3
padlocks).
NEMA 1, 12 RHVF12 RHVL12

Auxiliary Switch Kits


For Direct or Extended Rotary
Handle Operators (RHF and RHV).
Form C, Early Break type2 Aux. Switch Kit a
Includes 1 switch with 5’ wire
For Door-Mounted Operator — — RHSLA1
RHVFBM For Through-Door Operator RHSFA1F RHSLA1F
Includes 2 switches with 5’ wire
For Door-Mounted Operator — — RHSLA2
For Through-Door Operator RHSFA2F RHSLA2F

Door-Mounted Rotary Operator Mechanism


Breaker mechanism only RHVFBM RHVLBM

Door-Mounted Rotary Handle Only


Standard version NEMA 1, 12 RHVM12H RHVM12H
RHVM3RH NEMA 3R RHVM3RH RHVM3RH
NEMA 4X RHVM4XH RHVM4XH
Red Handle version RHVMEMH RHVMEMH
7

NFPA-79 Handle Kit


MOLDED CASE
CIRCUIT BREAKERS

Intermediate handle for NFPA-79 compliance


with door-mounted rotary operator RHVF79H RHVM79H

Extension Shaft Only, for Door Mounted Operator


2 inches (50.8mm) RHVMS02 RHVMS02
RHVMS12 3 inches (76.2mm) — — — —
12 inches (304.8 mm) RHVMS12 RHVMS12
16 inches (406.4 mm) RHVMS16 RHVMS16
24 inches (609.6mm) w/ support bracket RHVMS24 RHVMS24

RHVM12H

a During manual operation, Early Break auxiliary switch contacts open before the breaker opens.

7-196 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
For MG Frame For NG to PG Frame
800 A 1200 to 1600 A

Description Catalog Number Catalog Number
Through-Door Rotary Handle Operator Kit
Fixed depth, breaker mounted.
For direct fitting to the circuit breaker.
Lockable with up to 3 padlocks.
NEMA 1, 12 — — — —
Red Handle version
with red knob, yellow indicator plate
NEMA 1, 12 — — — —
Door-Mounted Rotary Handle Operator Kit
Variable depth, door mounted handle.
Includes knob with masking frame,
indicator plate, detachable door coupling,
12” shaft, and breaker mounted rotary
operator. Lockable knob (for up to 3
padlocks).
NEMA 1, 12 RHVM12 — —

Auxiliary Switch Kits


For Direct or Extended Rotary
Handle Operators (RHF and RHV).
Early Break type2 Aux. Switch Kit
Includes 1 switch with 5’ wire
For Door-Mounted Operator RHSMA1 RHSPA1
For Through-Door Operator — — — —
Includes 2 switches with 5’ wire
For Door-Mounted Operator RHSMA2 RHSPA2
For Through-Door Operator — — — —

Door-Mounted Rotary Operator Mechanism


Breaker mechanism only RHVMBM RHVPBM

Door-Mounted Rotary Handle Only


Standard version NEMA 1, 12 RHVM12H RHVP3RH
NEMA 3R RHVM3RH RHVP3RH
NEMA 4X RHVM4XH RHVP4XH
Red Handle version RHVMEMH RHVPEMH

7
NFPA-79 Handle Kit

CIRCUIT BREAKERS
MOLDED CASE
Intermediate handle for NFPA-79 compliance
with door-mounted rotary operator RHVM79H RHVP79H

Extension Shaft Only, for Door Mounted Operator


2 inches (50.8mm) RHVMS02 — —
3 inches (76.2mm) — — RHVPS03
12 inches (304.8 mm) RHVMS12 RHVPS12
16 inches (406.4 mm) RHVMS16 — —
24 inches (609.6mm) w/ support bracket RHVMS24 RHVPS24

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-197
External Accessories
Operating Mechanisms 

For DG and FG Frame For JG and LG Frame


150 to 250 A 400 to 600 A

Description Catalog Number Catalog Number


Variable Depth Flange Mounted Operator Kit
Adjustable from 8” to 16”
Complete kit, includes handle and
variable depth operator.
NEMA 1, 3R, 12 FHVF3R FHVL3R
NEMA 4X FHVF4X FHVL4X
IEC Black Handle NEMA 1, 3R, 12 FHVF3RB FHVL3RB
NEMA 4X FHVF4XB FHVL4XB

Max-Flex™, Variable Depth Flange


Mounted Operator Kit
Complete kit, includes plastic handle, breaker
operator, and cable. NEMA 1, 3R, 12 MFKF3R MFKL3R
For DG and FG operators, the cable is 36”,
all others are 48”
May be right- or left-hand mounted

Handle Only, for Max-Flex™ Variable Depth


NEMA 1, 3R, 12 Plastic MFHM3R MFHM3R
NEMA 1, 3R, 12 Steel - epoxy coated MFHM3RS MFHM3RS
NEMA 4, 4X Steel - chrome plated MFHM4X MFHM4X
Solid color (all gray) Plastica
NEMA 1, 3R, 12 MFHM3RB MFHM3RB
Solid color (black handle) Steel epoxy coateda
NEMA 1, 3R, 12 MFHM3RSB MFHM3RSB

Breaker Operator Mechanism Only, for Max-Flex™ MFMF MFML

Cable Only, for Max-Flex™ Variable Depth


36” MFCF036 MFCM036
48” MFCF048 MFCM048
60” MFCF060 MFCM060
72” MFCF072 MFCM072
84” MFCF084 MFCM084
96” MFCF096 MFCM096
120” MFCF120 MFCM120
144” MFCF144 MFCM144

Handle Auxiliary Switch


Form C (1NO - 1NC), early breakb
7

1 Aux. switch MFSFA1 MFSLA1


2 Aux. switch MFSFA2 MFSLA2
MOLDED CASE
CIRCUIT BREAKERS

a Max-Flex™ handles are available with solid gray or black handles instead of the customary “Red for On” flange handle.
The black handle is preferred for IEC markets, where red handles have a specific meaning.
b During manual operation, Early Break aux. contacts open before the breaker opens.

7-198 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
For MG Frame For NG Frame For PG Frame
800 A 1200 A 1600 A

Description Catalog Number Catalog Number Catalog Number


Variable Depth Flange Mounted Operator Kit
Adjustable from 8” to 16”
Complete kit, includes handle and
variable depth operator.
NEMA 1, 3R, 12 — —
NEMA 4X — —
IEC Black Handle NEMA 1, 3R, 12 — —
NEMA 4X — —

Max-Flex™, Variable Depth Flange


Mounted Operator Kit
Complete kit, includes plastic handle, breaker
operator, and cable. NEMA 1, 3R, 12 MFKM3R MFKP3RS MFKP3RS
For DG and FG operators, the cable is 36”,
all others are 48”
May be right- or left-hand mounted

Handle Only, for Max-Flex™ Variable Depth


NEMA 1, 3R, 12 Plastic MFHM3R — —
NEMA 1, 3R, 12 Steel - epoxy coated MFHM3RS MFHP3RS MFHP3RS
NEMA 4, 4X Steel - chrome plated MFHM4X MFHP4X MFHP4X
Solid color (all gray) Plastica
NEMA 1, 3R, 12 MFHM3RB — —
Solid color (black handle) Steel epoxy coateda
NEMA 1, 3R, 12 MFHM3RSB MFHP3RSB MFHP3RSB

Breaker Operator Mechanism Only, for Max-Flex™ MFMM MFMP MFMP

Cable Only, for Max-Flex™ Variable Depth


36” MFCM036 — —
48” MFCM048 MFCP048 MFCP048
60” MFCM060 MFCP060 MFCP060
72” MFCM072 MFCP072 MFCP072
84” MFCM084 — —
96” MFCM096 MFCP096 MFCP096
120” MFCM120 MFCP120 MFCP120
144” MFCM144 MFCP144 MFCP144

Handle Auxiliary Switch


Form C (1NO - 1NC), early breakb

7
1 Aux. switch MFSPA1 MFSPA1 MFSPA1
2 Aux. switch MFSPA2 MFSPA2 MFSPA2

CIRCUIT BREAKERS
MOLDED CASE

a Max-Flex™ handles are available with solid gray or black handles instead of the customary “Red for On” flange handle.
The black handle is preferred for IEC markets, where red handles have a specific meaning.
b During manual operation, Early Break aux. contacts open before the breaker opens.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-199
Revised on 11/30/19

External Accessories
Operating Mechanisms 

For DG to FG Frame
150 to 250 A

Description Catalog Number
Stored Energy and Motor Operators
Lockable with up to 3 padlocks.
AC Voltage DC Voltage Stored Energy Type
— 24 SEAFB
42-48 42-48 SEAFM
60 60 SEAFY
110–127 110–127 SEAFN
220–250 220–250 SEAFR
Cylinder Locks for Field Installation CLKF

Connections 

For DG Frame For FG Frame


150 A 250 A

Description Catalog Number Catalog Number
Front Bus Bar Connections
Includes nut keeper plates and shield.
Standard (straight)
3-Pole Set FBCD3 FBCF3
Bus Bar Connection Strap Kit — —
Includes 6 - Bus Bars, 6 Nut Keepers & Shields — —
Standard 3-Pole Set
7

100% rated applications

Terminal Shields
MOLDED CASE
CIRCUIT BREAKERS

Includes 2 terminal shields.


3-Pole Standard Shield TSSF3 TSSF3
3-Pole Extended Shield TSLF3 TSLF3

Interphase Barriers
Set of 2 barriers IPBF IPBF
Also fits plug-in and draw-out bases.
Terminal Shields
Lug Mounting Assy. — —

Breaker Mounting Base


Front connected — —
Rear connected — —

IPBF

7-200 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 11/30/19

For JG to LG Frame For MG Frame For NG to PG Frame


400 to 600 A 800 A 1200 to 1600 A

Catalog Number Catalog Number Catalog Number

Stored Energy Type Stored Energy Type Motor Operator Type


SEALB SEAMB MTRPB
SEALM SEAMM MTRPM
SEALY SEAMY MTRPY
SEALN SEAMN MTRPN
SEALR SEAMR MTRPR
CLKP CLKP CLKP

For JG Frame For LG Frame For MG Frame For NG Frame For PG Frame
400 A 600 A 800 A 1200 A 1600 A

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number


FBCJ3 FBCL3 FBCM3
— — — SSBP SSBP
SSBPH SSBPH

CIRCUIT BREAKERS
MOLDED CASE
TSSL3 — TSSM3 TSSP3 TSSP3
TSLL3 — TSLM3 TSLP3 TSLP3

IPBM IPBM IPBM IPBP IPBP

— — — — LMAP1600b

— — — — MBPG1600
— — — — MBPG1601

a Not for use with standard Al terminals. Use Standard b Kit includes connection for one side of breaker only.
Shield for rear connection and Extended Shield for bus- Order quantity 2 if connecting line and load side.
bar connection.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-201
External Accessories
Connections 

For DG Frame For FG Frame


150 A 250 A

Description Catalog Number Catalog Number


Nut Keeper Plates
For ring/tongue terminal or bus bar connections.
(For metric threads on other than the JG frame,
change ”TNK” to ”TMK”)
1 Nut Keeper Plate TNKD TNKF
Kit of 3 TNKD3 TNKF3

TNKD3

Mechanical Lugs
Steel Wrap Around Body (Cu Wire Only)
Cable Size; (cables per phase) #8-1/0; 1-hole #4-350 kcmil; 1-hole
Single Lug TW1DG20 TW1FG350
Kit of 3 3TW1DG20 3TW1FG350
Aluminum Body (Al or Cu Wire)
Cable Size; (cables per phase) #6-3/0; 1-hole #4-350 kcmil; 1-hole
Single Lug TA1DG30 TAW1FG350
Kit of 2 — —

Kit of 3 3TA1DG30 3TAW1FG350

Cable Size; (cables per phase) — —



Single Lug — —
Kit of 2 — —
Kit of 3 — —

Cable Size; (cables per phase) — —
Single Lug — —
3TA2LG600LD
— —
Copper Body (Cu Wire Only)
Cable Size; (cables per phase) #6-3/0; 1-hole #4-350 kcmil; 1-hole
Single Lug TC1DG30 TCW1FG350
Kit of 2 — —

Kit of 3 3TC1DG30 3TCW1FG350

Cable Size; (cables per phase) — —
7

Single Lug — —
3TA4NG500
MOLDED CASE
CIRCUIT BREAKERS

Compression Lugs
Cable Size; (cables per phase) #14-2/0; 1-cable #4-350 kcmil; 1-cable
Kit of 2 2CLD20 —
Kit of 3 3CLD20 3CLF350

Cable Size; (cables per phase) —


Kit of 2 —
Kit of 3 — —

Cable Size; (cables per phase) — —


Kit of 3 — —
­­Distribution Lugs (Cu Wire Only) #14-#1; 2-hole and
Cable Size; (cables per phase) #14-#2; 3-hole #14-2/0; 1-hole
Single Lug TA3DG02 TA3FG20
Kit of 3 3TA3DG02 3TA3FG20
Cable Size; (cables per phase) #14-#4; 6-hole #14-#4; 6-hole
Single Lug TA6DG04 TA6FG04
Kit of 3 3TA6DG04 3TA6FG04

Note: pictures provide graphical


representaions only. Control Wire Terminals
Control Wire Terminal (Single) — —
Control Wire Terminal (Kit of 3) — —

 Required for 100% rated breakers. Requires 90°C cable


sized at 75°C ampacity.

7-202 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
For JG Frame For LG Frame For MG Frame For NG Frame For PG Frame
400 A 600 A 800 A 1200 A 1600 A

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number

TMKJ TNKL TNKM TNKP TNKP


TMKJ3 TNKL3 TNKM3 TNKP3 TNKP3
metric only


1/0-600 kcmil; 1-hole — — — —
TW1JG600 — — — —
3TW1JG600 — — — —

3/0-250 kcmil; 2-hole #2-600 kcmil; 2-hole 1/0-500 kcmil, 3-hole 1/0-500 kcmil; 4-hole 1/0-750 kcmil; 6-hole
TA2JG250 — TA3MG500 — —
— — 3TA3MG500 2TA4NG500 —

3TA2JG250 3TA2LG600LDa 3TA4NG500 3TA6PG750e
3TA2LG600LNb 3TA4NG500Hc

AL: 250-750 kcmil AL: 250-750 kcmil


CU: 3/0-600 kcmil; 1-hole CU: 3/0-600 kcmil; 1-hole 500 -750 kcmil; 2-hole 500 -750 kcmil; 3-hole 600-750 kcmil; 4-hole
TA1JG750 TA1JG750 (400A max) TA2MG750 — TA4P750f
— — — 2TA3NG750
3TA1JG750 3TA1JG750 (400A max) 3TA2MG750 3TA3NG750 —

— #2-600 kcmil; 3-hole — 300-600 kcmil; 5; 6-hole
— — — TA5P600f
TA6R600f
— — 3TA3MG600d (Kit of 3) — —

3/0-250 kcmil; 2-hole #2-600 kcmil; 2-hole 1/0-500 kcmil; 3-hole 1/0-500 kcmil; 4-hole —
TC2JG250 — TC3MG500 — —
— — — — —

— 3TC2LG600LD — 3TC4NG500 —
3TC2LG600LN
3/0-750 kcmil; 1-hole — — — 300-600 kcmil; 5-hole

7
TC1JG750 — — — TC5R600f

CIRCUIT BREAKERS
MOLDED CASE

#6-350 kcmil; 1-cable #6-350 kcmil; 2-cable 1/0-500 kcmil; 4-cable —
— — — — —
3CLJ350 6CLL350 (kit of 6) — 12CLN500 (kit of 12) —

250-600 kcmil; 1-cable 250-750 kcmil; 1-cable — — —


3CLJ600 3CLL750 — — —
— — — — —
250-600 kcmil; 2-cable
6CLL600 (kit of 6) — — —
— — — — —
­­
#14-#4; 12-hole — — — —
TA12JG04 — — — —
3TA12JG04 — — — —
#14-2/0; 6-hole — — — —
TA6JG20 — — — —
3TA6JG20 — — — —


TA2JG250PT — TA3MG500PT — —
— 3TA2LG600LNPT — 3TA4NG500PT —

All lug kits include the nut keepers. c Required for 100% rated breakers. Requires 90°C cable e Used only with LMAP1600 mounting base.
a Mounted on Load Side Only. sized at 75°C ampacity. f Used only with MBPG1600 or MBPG1601 mounting
b Mounted on Line Side Only. d Requires extended modified shield. base.

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-203
Revised on 11/30/19

External Accessories
General 

For DG Frame For FG Frame


150 A 250 A

Description Catalog Number Catalog Number
Handle Padlocking Device HPLF HPLF
To padlock breaker toggle in the “OFF” position. Accepts up
to 3 padlocks with 5–8 mm shackles.

Handle Blocking Device HBDF HBDF


For holding the handle in the “ON” position. Not a
lockout/tagout device.

Cable Interlock Mechanism


Provides mechanical interlocking between 2 circuit-breakers -
Handle Padlocking includes operator mechanism for one circuit breaker only. CBTF CBTF
Device Combination with the next larger or smaller frame size is possible.
Interlock Cable
Cable only, to connect 2 circuit breakers.
Cable length 18 in. .46m (recommended up to 250A) CBCF18 CBCF18
Cable length 36 in. .91m (recommended from 400–800A) CBCM36 CBCM36
Cable length 54 in. 1.37m (recommended from 1200–1600A) CBCP54 CBCP54

Mounting Screw Kit


Includes the necessary hardware to mount a circuit breaker to the
user’s prepared surface
Kit with 2 screws (SAE thread) MSKF2 MSKF2
Kit with 4 screws (SAE thread) MSKF4 MSKF4
Trip Adjustment Sealing Cover
Includes a trip unit cover to prevent tampering or adjustment
Cable Interlock of trip settings. Seal not included. 3VL97008BL00 3VL97008BL00
System
7 MOLDED CASE
CIRCUIT BREAKERS

7-204 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 11/30/19

For JG Frame For LG Frame For MG Frame For NG Frame For PG Frame
400 A 600 A 800 A 1200 A 1600 A

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
HPLL HPLL HPLM HPLP HPLP

HBDL HBDL HBDM HBDP HBDP

CBTL CBTL CBTM CBTP CBTP

— — — — —
CBCM36 CBCM36 CBCM36 — —
CBCP54 CBCP54 CBCP54 CBCP54 CBCP54

— — — — —
MSKL4 MSKL4 MSKM4 MSKP4 MSKP4

3VL97008BL00 3VL97008BL00 3VL97008BL00 3VL97008BL00 3VL97008BL00

7
CIRCUIT BREAKERS
MOLDED CASE

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-205
Revised on 10/31/18

External Accessories
Ground Sensors & Electronic Accessories 

For DG Frame For FG Frame


150 A 250 A

Description Catalog Number Catalog Number
NGSF150 Neutral Current Transformer (Ground Sensor, N-pole)
Neutral = 35/60A NGSD060 —
Neutral = 100A NGSF100 NGSF100
Neutral = 150A NGSF150 NGSF150
Neutral = 250A — NGSJ250
Neutral = 400A — —
Neutral = 600A — —
Neutral = 800A — —
Neutral = 1000/1200A — —
Neutral = 1600A — —
NGSM600

Communications & Electronics


Power Stick - Hand held, battery operated power supply
for LCD trip units. (Requires two 9V batteries.) Trip test- EPSP18V EPSP18V
ing for both 555 & 586 trip units.
Spare Flat Spare flat cable for Power Stick. COMPCA COMPCA
Cable
COM20 Profibus Communications Module with ZSI for
Power Stick COMPRO20 COMPRO20
electronic trip units (order cable separately)

COM21 Modbus Communications Module with ZSI for


COMMOD21 COMMOD21
electronic trip units (order cable separately)

Cable for COM20/21, 1.5 m (4.9 ft) COMKIT3 COMKIT3

Cable for COM20/21, 3.0 m (9.8 ft) COMKIT6 COMKIT6

Addressing Plug - assigns a field bus address without a


3UF79100AA000 3UF79100AA000
PC by plugging into COM20/21
7

Com20 Profibus
& Com21 Modbus
Communications
MOLDED CASE
CIRCUIT BREAKERS

Module

Door Cutouts & Extensions

Cover Frame for Door Cutout


For fixed or plug-in mounted circuit breakers. (IP30)
2-Pole & 3-Pole BZLF3 BZLF3

For breakers with stored energy operator. (IP40) BZLFRHSE BZLFRHSE


Cover Frame for
Door Cutout Circuit-breaker draw-out mounted and toggle handle operated.
Kit includes cover frame (bezel) and escutcheon as needed. (IP40)
(not for use with rotary handle or stored energy operator) BZLFBDC BZLFBDC

Toggle Handle Extension — —


THEL For spare or replacement. (One is included with each
NG - PG frame.)

THEP

7-206 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog Product Category MCCB
Revised on 11/30/19

For JG Frame For LG Frame For MG Frame For NG Frame For PG Frame
400 A 600 A 800 A 1200 A 1600 A

Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number

— — — — —
— — — — —
— — — — —
NGSJ250 — — — —
NGSL400 NGSL400 — — —
— NGSM600 NGSM600 — —
— — NGSN800 NGSN800 —
— — — NGSP120 NGSP120
— — — — NGSP160

EPSP18V EPSP18V EPSP18V EPSP18V EPSP18V

COMPCA COMPCA COMPCA COMPCA COMPCA

COMPRO20 COMPRO20 COMPRO20 COMPRO20 COMPRO20

COMMOD21 COMMOD21 COMMOD21 COMMOD21 COMMOD21

COMKIT4 COMKIT4 COMKIT5 COMKIT5 COMKIT5

COMKIT7 COMKIT7 COMKIT8 COMKIT8 COMKIT8

3UF79100AA000 3UF79100AA000 3UF79100AA000 3UF79100AA000 3UF79100AA000

7
CIRCUIT BREAKERS
MOLDED CASE
BZLL3 BZLL3 BZLM3 BZLP3 BZLP3

BZLLRHSE BZLLRHSE BZLMRHSE BZLPRHSE BZLPRHSE

BZLLBDC BZLLBDC

THEL THEL THEM THEP THEP

Product Category MCCB Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-207
VL Circuit Breakers
Accessory Locations Selection

Locations of Internally Mounted Accessories


Frame Family Left Pocket Right Pocket

Shunt Trip or UVR or up to 3 Auxiliary Switches


Up to 3 Auxiliary Switches
DG*, FG*, JG, LG or up to 2 Auxiliary Switches + 1 Alarm Switch
150 to 600A
Shunt Trip or UVR or up to 3 Auxiliary Switches
Up to 2 Auxiliary Switches + 1 Alarm Swich
or up to 2 Auxiliary Switches + 1 Alarm Switch


Up to 4 Auxiliary Switches Shunt Trip or UVR or up to 4 Auxiliary Switches
MG, NG, PG
800 to 1600A
Up to 2 Auxiliary Switches + 2 Alarm Swiches Shunt Trip or UVR or up to 4 Auxiliary Switches

* Except DG and FG breakers with Electronic Trip Units. Due to the location of the Magnetic Latch, the Left Pocket is not available for accessories.

Accessory Information Accessory Maximums


b Aux. Switch is an Auxiliary Switch, 1A DG, FG, JG, LG Maximum Accessories:
or 1B contact
b Maximum of six (6) switches total
b Alarm Switch has 1A or 1B contact b DG, FG Maximum of two (2) Alarm
b UVR is an Undervoltage Release Switches, one each in the Left and
Right Pockets. JG, LG Max. of 1 Alarm,
b The standard location for factory
mounted Auxiliary and Alarm Switches Left only
is the Left Pocket MG, NG, PG Maximum Accessories:
b Maximum of eight (8) switches total
b Maximum of two (2) Alarm Switches,
7

Left Pocket only


MOLDED CASE
CIRCUIT BREAKERS

For applications using COMMOD20 and COMMOD21 for


communication using Modbus or Profibus

DG, FG MG, NG, PG


COMKIT3 & COMKIT6 provide auxiliary COMKIT5 & COMKIT8 provide auxiliary
contact kit. May add only one or two contact kit mounted in Left pole pocket.
contact blocks for Alarm or Auxiliary Two contact blocks can be added for
function. Auxiliary function and one for Alarm
JG, LG function. Right pole pocket available for
other release or an additional Auxiliary
COMKIT4 & COMKIT7 provide auxiliary
Contact kit.
contact kit mounted in left pole pocket.
One contact block can be added for
Auxiliary function. Right pole pocket
available for other release or an addi-
tional Auxiliary contact kit.

7-208 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


VL Circuit Breakers
Selection

Suffix for factory mounted Switch Combinations


Then add Device
If the frame is: And you need these functions: this suffix: Catalog Number
1 Alarm Switch
DG, FG, JG or LG 1 NO Alarm A1 ASKL1
1 NC Alarm
2 Aux. Switches
DG, FG, JG or LG A2 ASKL2
1 NO + 1 NC Aux. Contacts
2 Aux. + 1 Alarm Switches
DG, FG, JG or LG 1NO + 1NC Aux. and 1NC Alarm A3 ASKL3
2NO Aux. and 1NC Alarm
2 Aux. + 2 Alarm Switches
1NO + 1NC Aux. and 1NO + 1NC Alarm
MG, NG or PG A3 ASKP3
2NO Aux. and 2NC Alarm
2NC Aux. and 2NO Alarm
4 Aux. Switches
MG, NG or PG A4 ASKP4
2NO + 2NC Aux.

Suffix for factory mounted Shunt Trips


Then add Device
If the frame is: And you need these functions: this suffix: Catalog Number
24V DC RB STRLB24DC
48-60V DC RC STRLC60DC
110-127V DC RD STRLD125DC
220-250V DC RE STRLE250DC
DG, FG, JG or LG
48-60V AC RM STRLM60
110-127V AC RN STRLN120
208-277V AC RS STRLS277
380-600V AC RV STRLV600
24V DC RB STRPB24DC
48-60V DC RC STRPC60DC
110-127V DC RD STRPD125DC
220-250V DC RE STRPE250DC
MG, NG or PG
48-60V AC RM STRPM60
110-127V AC RN STRPN120
208-277V AC RS STRPS277
380-600V AC RV STRPV600

7
Suffix for factory mounted Undervoltage Releases
Then add Device

CIRCUIT BREAKERS
MOLDED CASE
If the frame is: And you need these functions: this suffix: Catalog Number
12V DC UA UVRLA12DC
24V DC UB UVRLB24DC
48V DC UC UVRLC48DC
60V DC UG UVRLG60DC
110-127V DC UD UVRLD125DC
220-250V DC UE UVRLE250DC
DG, FG, JG or LG 24V AC UK UVRLL24
110-127V AC UN UVRLN120
220-240V AC UR UVRLR240
208V AC UP UVRLP208
277V AC US UVRLS277
380-415V AC UT UVRLT415
440-480V AC UU UVRLU480
12V DC UA UVRPA12DC
24V DC UB UVRPB24DC
48V DC UC UVRPC48DC
60V DC UG UVRPG60DC
110-127V DC UD UVRPD125DC
220-250V DC UE UVRPE250DC
MG, NG or PG 110-127V AC UN UVRPN120
220-240V AC UR UVRPR240
208V AC UP UVRPP208
277V AC US UVRPS277
380-415V AC UT UVRPT415
440-480V AC UU UVRPU480

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-209


Technical Data

DG FG JG LG MG NG PG
Max rated continuous current 150 250 400 600 800 1200 1600
Rated operational voltage
NEMA V AC 600 600 600 600 600 600 600
IEC V AC 690 690 690 690 690 690 690
Rated Impulse Withstand Voltage
Main conducting paths kV 8 8 8 8 8 8 8
Auxiliary circuits kV 4 4 4 4 4 4 4
Ambient Temperature Range ºC -25 to +75 -25 to +75 -25 to +75 -25 to +75 -25 to +75 -25 to +75 -25 to +75
High Ambient Derating (thermal-mag.) 50ºC 93% 93% 93% 93% 95% 95% 95%
60ºC 86% 86% 86% 86% 86% 86% 80%
70ºC 80% 80% 80% 80% 80% 80% 74%
Operating Cycles 20,000 20,000 20,000 10,000 5,000 3,000 3,000
Max switching rate (per hour) 120 120 120 60 60 30 30
Power loss (at max. rated current)
Thermal-magnetic W 15 – 48 32 – 80 60 – 175 85 – 230 170 – 250 150 – 220 200 – 260
Electronic trip unit W 40 60 90 160 250 210 260
IEC 1
Time constant t = 10 ms
1 current path 2 current paths 3 current paths
in series in series
Up to 250V DC 440V DC 600V DC — — — — — — —
NEMA
Time constant t = 8 ms
2 poles switching 1 current path
250V DC Max. 2 30 30 30 30 42 42 42
3 poles switching 2 current paths in series
500V DC Max. 2 18 25 35 35 65 65 65
Accessories
Auxiliary/ Alarm Switch
Current rating (1 or 2 switches) 10 10 10 10 10 10 10
Current rating (3 or 4 same switch) A 5 5 5 5 5 5 5
Shunt Trip
Pick-up voltage V 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1 0.7 – 1.1
7

Power Consumption (short-time) at:


48 – 60 V AC VA 401 – 501 401 – 501 401 – 501 401 – 501 401 – 501 401 – 501 401 – 501
MOLDED CASE
CIRCUIT BREAKERS

110 – 127 V AC VA 424 – 489 424 – 489 424 – 489 424 – 489 424 – 489 424 – 489 424 – 489
208 – 277 V AC VA 533 – 736 533 – 736 533 – 736 533 – 736 533 – 736 533 – 736 533 – 736
380 – 600 V AC VA 408 – 645 408 – 645 408 – 645 408 – 645 408 – 645 408 – 645 408 – 645
24 V DC W 594 594 594 594 594 594 594
48 – 60 V DC W 740 – 925 740 – 925 740 – 925 740 – 925 740 – 925 740 – 925 740 – 925
110 –127 V DC W 559 – 648 559 – 648 559 – 648 559 – 648 559 – 648 559 – 648 559 – 648
220 – 250 V DC W 722 – 820 722 – 820 722 – 820 722 – 820 722 – 820 722 – 820 722 – 820
Max. Operating time ms 50 50 50 50 50 50 50
1 Consult Siemens for short circuit values.
2 Review individual frame and type values.

7-210 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/18

Technical Data

DG FG JG LG MG NG PG
Undervoltage Trip
Drop voltage (percentage) V 35% – 70% 35% – 70% 35% – 70% 35% – 70% 35% – 70% 35% – 70% 35% – 70%
Pick-up voltage (percentage) V 70% – 85% 70% – 85% 70% – 85% 70% – 85% 70% – 85% 70% – 85% 70% – 85%
Power consumption (continuous) at:
110 – 127 V AC VA 1 1 1 1 1.1 1.1 1.1
220 – 250 V AC VA 2.1 2.1 2.1 2.1 2.1 2.1 2.1
208 V AC VA 1.2 1.2 1.2 1.2 1.2 1.2 1.2
277 V AC VA 1.4 1.4 1.4 1.4 1.4 1.4 1.4
380 – 415 V AC VA 1.9 1.9 1.9 1.9 1.9 1.9 1.9
440 – 480 V AC VA 2.2 2.2 2.2 2.2 2.2 2.2 2.2
500 – 525 V AC VA 2.5 2.5 2.5 2.5 2.5 2.5 2.5
600 V AC VA 2.8 2.8 2.8 2.8 2.8 2.8 2.8
Max. opening time ms 50 50 50 50 50 50 50
Motorized Operating Mechanism
Motor with stored energy mechanism
(synchronizable) X X X X
Motor Operator X X X
Max. switching rate (per hour) 120 120 120 60 60 30 30
Command duration ms 20 – 50 20 – 50 20 – 50 20 – 50 20 – 50 — —
Closing time ms <100 <100 <100 <100 <100 <5,000 <5,000
Charging time s <5 <5 <5 <5 <5 <5 <5
Break time s <5 <5 <5 <5 <5 <5 <5
Power consumption VA/W <100 <100 <200 <250 <250
Inrush (A)
Control Voltages 110 – 127 V AC
220 – 250 V AC
24 V DC
48 V DC
60 V DC
Operating Range 85 – 110% of rated control voltage

7
CIRCUIT BREAKERS
MOLDED CASE

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-211


Revised on 11/30/17

Technical Data
Unusual Operating Conditions Reference

Note: The information provided on Table 1 – Temperature derating data for thermal-magnetic breakers
this and the next page is intended for
Reference Ampere Ampere Rating at:
reference and recommendation only.
Rating at 50°C 60° C
Because several variables can act on 40° C (104° F) (122° F) (140° F) Siemens Breaker Frames
a circuit breaker’s performance at the 50 46 42
same time, the data below is based less 60 56 52
on controlled testing, than on experi- 70 65 60
ence and engineering judgment. Contact 90 84 78 DG
Siemens for further information on 100 94 87
special conditions and treatment. 125 114 100
150 136 120
High Ambient Temperatures 175 159 140 FG
Because thermal-magnetic trip breakers 200 182 160
225 205 180
are temperature sensitive and calibrated
250 235 220
for a specific ambient of 40° C (104°
300 276 252 JG
F) (average enclosure temperature), a 350 325 301
higher ambient will cause the breaker 400 372 340
to trip at lower current than its name- 500 468 435 LG
plate rating, in other words, causing 600 564 525
the breaker to “derate” (see Table 1). 700 658 613 MG
Similarly, the current carrying capacity 800 754 704
of a circuit conductor is based upon a 900 828 749­­
NG
certain ambient temperature, a higher 1000 900 825
ambient will reduce its current carrying 1200 1090 1000
capacity, causing it to “derate.” Thus, 1400 1304 1148 PG
with a fluctuating temperature, a ther- 1600 1500 1320
mal-magnetic breaker will derate nearly
parallel with its connected circuit con-
ductors and maintain close circuit pro-
tection. If the application temperature
exceeds 40° C (104° F) and is known,
either a breaker specially calibrated for
the higher ambient or one oversized
7

according to Table 1 may be selected.


In a case such as this, the circuit con-
MOLDED CASE
CIRCUIT BREAKERS

ductors should be oversized as well.

Siemens Electronic Trip Unit Breakers


are insensitive to temperature changes.
However, they do include circuitry to
protect the components from abnor-
mally high temperatures.

Altitude
Reduced air density at altitudes greater
than 6600 ft. (2000 meters) affects the
ability of a molded case circuit breaker
to transfer heat and interrupt faults.
Therefore, circuit breakers applied at
these altitudes should have interrupt-
ing, insulation and continuous currents
derated as indicated in Figure 1.

Figure 1 – Altitude adjustment

7-212 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Technical Data
Unusual Operating Conditions Reference

Unusual Operating Conditions 400 Hz Systems


Circuit Breaker Derating Required Cable and Bus Sizing Application Recommendations
This table lists the maximum con- The cable and bus sizes to be utilized It is recommended that temperatures
tinuous current carrying capacity for at 400Hz are not based on standard be measured on the line and load termi-
Siemens breakers at 400Hz. Due to National Electric Codes tables for 60Hz nals or T-connectors of the center pole.
the increased resistance of the copper application. Larger cross sections are These are usually the hottest terminals
sections resulting from the skin effect necessary at 400Hz. All bus bars with a balanced load. A maximum
produced by eddy currents at these specified are based upon mounting the temperature of 75°C (35°C over a maxi-
frequencies, circuit breakers in many bars in the vertical plane to allow maxi- mum ambient of 40°C) would verify
cases require derating. The thermal mum air flow. All bus bars are spaced the particular application. Temperature
derating on these devices is based at a minimum of 0.25 in. (6 mm) apart. profiles taken on these breakers can
upon 100%, three phase application in Mounting of bus bars in the horizontal be correlated to ensure that the hottest
open air in a maximum of 40°C (104° F) plane will necessitate additional drafting. points within the breaker are within the
with 48 in. (1219 mm) of the speci- Edgewise orientation of the bus may required temperature limits.
fied cable or bus at the line and load change the maximum ratings indicated.
side. Additional derating of not less If additional information is required for Interrupting Rating
than 20% will be required if the circuit other connections of cable or bus, con- Circuit breakers used in 400 Hz sys-
breaker is to be utilized in an enclo- tact Siemens for information. tems are limited to a 5000 A interrupt-
sure. Further derating may be required ing rating. If higher ratings are required,
if the enclosure ambient temperature consult Siemens.
exceeds 40°C(104° F).

Maximum continuous ampere rating 75°C (167F) Maximum continuous ampere rating 75°C (167F)
at 40°C (104°F) Copper at 40°C (104°F) Copper
60HZ 400HZ cable per pole 60HZ 400HZ cable per pole
Breaker Enclosed after No of Breaker Enclosed after No of
type Open air Open air derating pieces Wire size type Open air Open air derating pieces Wire size
50 48 38 1 #8 400 300 240 2 #3/0
60 57 46 1 #6 LG 500 375 300 2 250 kcmil
70 63 50 1 #4 600 420 336 2 350 kcmil
80 72 58 1 #4 600 430 360 2 350 kcmil
DG 90 80 64 1 #3 MG 700 500 400 3 250 kcmil
100 90 72 1 #3 800 560 448 3 300 kcmil
600 430 430 2 350 kcmil

7
110 95 75 1 #2 MG
125 105 84 1 #1 100% 700 500 500 3 250 kcmil
150 125 100 1 #1/0 Rated 800 560 560 3 300 kcmil

CIRCUIT BREAKERS
MOLDED CASE
100 90 72 1 #3 800 560 448 3 300 kcmil
110 95 75 1 #2 900 600 480 3 350 kcmil
NG
125 105 84 1 #1 1000 650 520 3 400 kcmil
150 125 100 1 #1/0 1200 780 624 4 350 kcmil
FG 900 600 600 3 350 kcmil
175 140 112 1 #2/0 NG
200 160 128 1 #3/0 1000 650 650 3 400 kcmil
100%
1200 780 780 4 350 kcmil
225 180 144 1 #4/0 Rated
1200 780 624 4 400 kcmil
250 200 160 1 250 kcmil
1400 850 680 4 500 kcmil
250 210 168 1 250 kcmil
PG 1600 960 768 5 500 kcmil
300 240 192 1 350 kcmil
JG 1200 780 780 4 400 kcmil
350 260 208 1 500 kcmil
400 300 240 2 #2/0 PG 100% 1400 850 850 4 500 kcmil
JG 250 210 210 1 250 kcmil Rated 1600 960 960 5 500 kcmil
100% 300 240 240 1 350 kcmil
Rated 350 260 260 1 500 kcmil
­ 400 300 300 2 #3/0
400 300 240 2 #3/0
LG 500 375 300 2 250 kcmil
600 420 336 2 350 kcmil

 The information provided on this page is intended for judgment.Contact Siemens for further information on  Calculated after derating to compensate for the heating
reference and recommendation only. Because several special conditions and treatment. of the copper conductor, caused by the skin effect
variables can act on a circuit breaker’s performance at  Additional derating may be required if the ambient generated by eddy currents produced at 400/415HZ.
the same time, the data above is based less on con- temperature is greater than 40°C (104°F).
trolled testing, than on experience and engineering

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-213


Revised on 03/25/17

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

The term “Series Connected Short This is permitted as long as the series No substitutions are permitted. All com-
Circuit Rating” refers to the application of combination has been tested and certi- binations shown have been tested and
series circuit breakers in a combination fied by UL. are UL Listed. This information is provid-
that allows downstream breakers to have The tables on these pages list specific ed as a reference tool only. For verifica-
lower individual interrupting ratings than main and branch breaker combinations tion of specific combination ratings
the available fault current. that may be used for the short circuit consult the UL Recognized
interrupting ratings shown. Components Directory.

240V Breaker Series Ratings 240V Breaker Series Ratings (continued)


Main Breaker Branch Breaker Series Main Breaker Branch Breaker
Series
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
1 120/240 15-70 BAF, QAF, BQAF, QAF2,
QP, BQ, BL 2 240 15-125 70 (1P) BAF2, QAFH2, BAFH2, 1 120 15-20
HQP, HBQ,
3 240 15-100 125 (2P) QFGA2, BFGA2, QF-
HBL
QE, BLE, QPF, BLF 2 120/240 15-60 100 (3P) GAH2, BFGAH2
70 (1P) QE, BLE, BE, QPF, BAF, QAF 2 120/240 15-20
QPH, BQH, 1 240 15-30
125 (2P) BQF, BLF QPF2, BLF2 1 120/240 15-70
BLH QP, BQ, BL
100 (3P) QT 1, 2 120/240 15-40 2 240 15-125
QPH, BQH, BLH
QG, BG, BLG 1, 2 120/240 15-30 3 240 15-100
BAF, QAF, QAF2, BAF2, QPHF, BQHF, BLHF, QPF,
1 120 15-20
QFGA2, BFGA2 BQF, BLF, QE, QEH, BLEH,
1 120 15-30
BAF, QAF 2 120/240 15-20 BE, BLE, QPF2, BLF2,
120 15-25 QPHF2, BLHF2
QP 1 100
120/240 35-70 ED4, QEH, BLEH, QE, QPHF,
(1P) 2 120/240 15-60
15-25 ED4, ED6 BLHF,BLE, QPF, BLF
2 120/240 125
35-125 QAF2, BAF2, BAF, QAF,
QPMH 200 (2P) 1 15-30 (2P, 3P) BQAF, QAFH2, BAFH2,
QE, QPF 120/240
2 15-60 QAFH, BQAFH, BAFH, 1 120 15-20
1 120 15-20 QFGA2, BFGA2, QF-
QAF, BAF GAH2, BFGAH2
2 120/240 15-20
QT 2 120/240 15-30 QAF, BAF, QAFH, BAFH 2 120/240 15-20
1 120/240 15-70 ED2 1,2,3 120/240 15-100
QP, BQ, BL 2 240 15-125 QT 1,2 120/240 15-40
3 240 60-100 1 120/240 15-70
QPF, BQF, BLF, BG, BLG NDGA, 150
1 120 15-30 QPH, BQH, BLH 2 240 15-125
QE, BE, BLE, QPF2, BLF2 NDGB (2P, 3P)
225 3 240 15-100
QJH2 QPF, BLF, BG, BLG, QE
(2P, 3P) 2 120/240 15-60 QP, BQ, BL, 1 120/240 15-70
BE, BLE
QPH, BQH, BLH 2 120/240 15-125
BAF, QAF, QAF2, BAF2 1 120 15-20
22000 QPF, BQF, BLF, QPHF,
BAF, QAF 2 120/240 15-20
BQHF, BLHF, QEH, BLEH,
QT 1, 2 120/240 15, 20, 40 1 120/240 15-30
QE, BLE, BE, BLF2, QPF2,
QR2 2,3 240 100-225 QFGA2, BFGA2
1 120/240 15-70 QEH, BLEH, QE, QPHF,
QP, BQ, BL 2 120/240 15-60
2 120/240 15-125 225 BLHF, BLE, QPF, BLF
HQPP
QE, BLE, BE, QPF, BQF, (2P) BAF, QAF, BQAF, QAF2,
1 120 15-30
BLF, QPF2, BLF2 BAF2, QAFH2, BAFH2,
QPPH 225 (2P) QE, BLE, BE, QPF, BLF 2 120/240 15-60 1 120 15-20
QAFH, BQAFH, QFGAH2,
BAF, QAF, QAF2, BAF2 1 120 15-20
7

65000 BFGAH2
BAF, QAF 2 120/240 15-20 (cont.) BAF, QAF, QAFH, BAFH 2 120/240 15-20
QPP 2 120/240 125-200
QT 1, 2 120 15-40
QT 1, 2 120/240 15-40
MOLDED CASE
CIRCUIT BREAKERS

QPPH, QPP 2 120/240 125-200


1 120/240 15-70
2 120/240 15-125 1 120/240 15-70
QP,BQ,BL QP, BQ, BL
2 240 15-125 2 120/240 15-125
QPH, BQH, BLH
3 240 15-100 3 240 15-100
1 120 15-30 QPF, QPHF, BLF, BLHF 1,2 120/240 15-60
QG, BG, BLG QPF2, BLF2, QPHF2, 1 120 15-30
2 120/240 15-30
QT 1,2 120/240 15-50 BLHF2 2 120/240 15-60
250 QFGA2, BFGA2, QAF2, QAF, BAF, QAF2, BAF2,
QRH2 1 120 15-20 FD6-A,
(2, 3P) BAF2, QAF, BAF BQAF, QAFH2, BAFH2,
FXD6-A QAFH, BQAFH, BAFH, 1 120 15-20
QAF, BAF 2 120/240 15-20
QPF2, BLF2, QPF, BQF, QFGA2, BFGA2, QF-
1 120 15-30 GAH2, BFGAH2
BLF, QE, BLE, BE
QPF, BLF, QE, BLE 2 120/240 15-60 QAF, BAF, QAFH, BAFH 2 120/240 15-20
QN, QNR 2 120/240 150-200 QR2, QRH2 2,3 240 100-225
QS 2 120/240 100-225 QJ2H, QJ2, QJH2 2,3 240 60-225
QR2 2 120/240 100-250 QPPH 2 120/240 125-225
1 120/240 15-70 250 1 120/240 15-70
QP, BQ, BL 2 120/240 15-125 NFGA, (2P,3P) QPH, BQH, BLH 2 120/240 15-125
3 240 60-100 NFGB 3 240 15-100
225 1 120/240 15-70
42000 QJ2H QR2, QRH2 2,3 240 100-250
(2, 3P) QPH, BQH, BLH 2 120/240 15-125
3 240 15-100 1 120/240 15-70
QR2, QRH2 2,3 240 100-225 QP, BQ, BL 2 120/240 15-125
3 240 15-100
QJH2 2, 3 240 60-225
1 120/240 15-70 QT 1,2 120/240 15-50
QP, BQ, BL, QFGA2, BFGA2, QAF2,
2 240 15-125 1 120 15-20
QPH, BQH, BLH BAF2, QAF, BAF
3 240 15-100
QPF, BQF, BLF, BE, QPHF, HQR2 QAF, BAF 2 120/240 15-20
BQHF, BLHF, QEH, BLEH, QPF2, BLF2, QPF, BQF,
70 (1P) 1 120 15-30
HQP, HBQ, QE, BLE, QPF2, BLF2, 1 120 15-30 BLF, QE, BLE, BE
65000 125 (2P) QPF, BLF, QE, BLE 2 120/240 15-60
HBL QPHF2, BLHF2, QPHF2,
100 (3P)
BLHF2 1 120/240 15-70
QEH, BLEH, QE, QPHF, QPH, BQH, BLH 2 120/240 15-125
2 120/240 15-60
BLHF, BLE, QPF, BLF 3 240 15-100
QT 1, 2 120/240 15-40
QG, BG, BLG 1, 2 120/240 15-30

7-214 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/06/18

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

240V Breaker Series Ratings (continued) 240V Breaker Series Ratings (continued)
Series Main Breaker Branch Breaker Series Main Breaker Branch Breaker
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
QFGAH2, BFGAH2, QAFH2, 1 120/240 15-70
1 120 15-20
BAFH2, QAFH, BAFH QPH, BQH, BLH 2 120/240 15-125
QAFH, BAFH 2 120/240 15-20 3 240 15-100
QPHF, BLHF, QPHF2, QAF2, BAF2, QAFH2,
HQR2 250 1 120 15-30
BLHF2, QEH, BLEH NMG, BAFH2, QFGA2, BFGA2, 1 120 15-20
(cont.) (2P, 3P)
QEH, BLEH, QPHF, BLHF 2 120/240 15-60 HMG QFGAH2, BFGAH2
QN, QNH, QNR, QNRH 2 120/240 150-200 QPF2, BLF2, QPHF2, BLHF2 1 120 15-30
QS, QSH, QSHH 2 120/240 100-225 QR2, QRH2 2,3 240 100-250
QR2, QRH2 2,3 240 100-250 QN, QNH 2 120/240 150-200
1 120/240 15-70 QNR, QNRH 2 120/240 150-200
QPH, BQH, BLH 2 120/240 15-125 1 120/240 15-70
3 240 15-100 QPH, BQH, BLH 2 120/240 15-125
800
JXD2-A, QAF2, BAF2, QAFH2, 3 240 15-100
(2P, 3P)
JD6-A BAFH2, QFGA2, BFGA2, 1 120 15-20 SMD6 QAF2, BAF2, QAFH2,
(cont.)
JXD6-A QFGAH2, BFGAH2 SMD6-B BAFH2, QFGA2, BFGA2, 1 120 15-20
QPF2, BLF2, QPHF2, BLHF2 1 120 15-30 QFGAH2, BFGAH2
QR2, QRH2 2,3 240 100-250 QPF2, BLF2, QPHF2, BLHF2 1 120 15-30
QJ2H, QJH2 2,3 240 60-225 QR2, QRH2 2,3 240 100-250
1 120/240 15-70 1 120/240 15-70
QPH, BQH, BLH 2 120/240 15-125 QPH 2 120/240 15-125
NJGA/ 3 240 15-100 3 240 15-100
NJJA QR2, QRH2 2,3 240 100-250 HMXD6 QAF2, BAF2, QAFH2,
QN, QNH 2 120/240 150-200 HMD6 BAFH2, QFGA2, BFGA2, 1 120 15-20
400 QNR, QNRH 2 120/240 150-200 QFGAH2, BFGAH2
(2P, 3P) 1 120/240 15-70 QPF2, BLF2, QPHF2,
1 120 15-30
QPH, BQH, BLH 2 120/240 15-125 BLHF2
3 240 15-100 1 120/240 15-70
SJD6-A QAF2, BAF2, QAFH2, QPH, BQH, BLH 2 120/240 15-125
SJD6-B BAFH2, QFGA2, BFGA2, 1 120 15-20 3 240 15-100
QFGAH2, BFGAH2 QAF2, BAF2, QAFH2,
QPF2, BLF2, QPHF2, BLHF2 1 120 15-30 ND6, NXD BAFH2, QFGA2, BFGA2, 1 120 15-20
QR2, QRH2 2,3 240 100-250 QFGAH2, BFGAH2
1 120/240 15-70 QPF2, BLF2, QPHF2,
1 120 15-30
QPH 2 120/240 15-125 BLHF2
3 240 15-100 QR2, QRH2 2,3 240 100-250
HJD6-A, 1 120/240 15-70
QAF2, BAF2, QAFH2,
HJXD6 QPH, BQH, BLH 2 120/240 15-125
BAFH2, QFGA2, BFGA2, 1 120 15-20
QFGAH2, BFGAH2 3 240 15-100
QPF2, BLF2, QPHF2, BLHF2 1 120 15-30 QAF2, BAF2, QAFH2,
1 120/240 15-70 BAFH2, QFGA2, BFGA2, 1 120 15-20
QPH, BQH, BLH 2 120/240 15-125 NNG, HNG QFGAH2, BFGAH2
65000 3 240 15-100 65000 QPF2, BLF2, QPHF2,
1 120 15-30
(cont.) QR2, QRH2 2,3 240 100-250 (cont.) BLHF2
LD6-A QR2, QRH2 2,3 240 100-250
QAF2, BAF2, QAFH2, 1200
LXD6-A QN, QNH 2 120/240 150-200
BAFH2, QFGA2, BFGA2, 1 120 15-20 (2P, 3P)
QFGAH2, BFGAH2 QNR, QNRH 2 120/240 150-200
1 120/240 15-70

7
QPF2, BLF2, QPHF2, BLHF2 1 120 15-30
QJ2H, QJH2 2,3 240 60-225 QPH, BQH, BLH 2 120/240 15-125
1 120/240 15-70 3 240 15-100
QPH, BQH, BLH 2 120/240 15-125 QAF2, BAF2, QAFH2,

CIRCUIT BREAKERS
MOLDED CASE
SND6
3 240 15-100 BAFH2, QFGA2, BFGA2, 1 120 15-20
SND6-B
QR2, QRH2 2,3 240 100-250 QFGAH2, BFGAH2
NLGA, QAF2, BAF2, QAFH2, QPF2, BLF2, QPHF2,
1 120 15-30
NLGB BAFH2, QFGA2, BFGA2, 1 120 15-20 BLHF2
QFGAH2, BFGAH2 QR2, QRH2 2,3 240 100-250
QPF2, BLF2, QPHF2, BLHF2 1 120 15-30 1 120/240 15-70
QN, QNH 2 120/240 150-200 QPH 2 120/240 15-125
600 3 240 15-100
QNR, QNRH 2 120/240 150-200
(2P, 3P) HND6, QAF2, BAF2, QAFH2,
1 120/240 15-70
QPH, BQH, BLH 2 120/240 15-125 HNXD6 BAFH2, QFGA2, BFGA2, 1 120 15-20
3 240 15-100 QFGAH2, BFGAH2
QAF2, BAF2, QAFH2, QPF2, BLF2, QPHF2,
SLD6-A 1 120 15-30
BAFH2, QFGA2, BFGA2, 1 120 15-20 BLHF2
SLD6-B 1 120/240 15-70
QFGAH2, BFGAH2 SPD6,
QPF2, BLF2, QPHF2, QPH, BQH, BLH 2 120/240 15-125
1 120 15-30 SPD6-B,
BLHF2 3 240 15-100
PD6, PXD6
QR2, QRH2 2,3 240 100-250 QR2, QRH2 2,3 240 100-250
1 120/240 15-70 1 120/240 15-70
QPH 2 120/240 15-125 QPH, BQH, BLH 2 120/240 15-125
1600
3 240 15-100 3 240 15-100
NPG (2P, 3P)
QR2, QRH2 2,3 240 100-250
HLD6-A, QN, QNH 2 120/240 150-200
HLXD6-A QNR, QNRH 2 120/240 150-200
QAF2, BAF2, QAFH2,
BAFH2, QFGA2, BFGA2, 1 120 15-20 1 120/240 15-70
HPD6,
QFGAH2, BFGAH2 QPH 2 120/240 15-125
HPXD6
QPF2, BLF2, QPHF2, BLHF2 1 120 15-30 3 240 15-100
1 120/240 15-70 1 120/240 15-70
HRD6,
QPH, BQH, BLH 2 120/240 15-125 QPH 2 120/240 15-125
HRXD6
3 240 15-100 3 240 15-100
MD6, 800 QAF2, BAF2, QAFH2, 2000 QR2, QRH2 2,3 240 100-250
MXD6 (2P, 3P) BAFH2, QFGA2, BFGA2, 1 120 15-20 (2P, 3P)
1 120/240 15-70
QFGAH2, BFGAH2 RD6, RXD6
QPH, BQH, BLH 2 120/240 15-125
QPF2, BLF2, QPHF2, BLHF2 1 120 15-30 3 240 15-100
QR2, QRH2 2,3 240 100-250

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-215


Revised on 03/25/17

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

240V Breaker Series Ratings (continued) 240V Breaker Series Ratings (continued)
Series Main Breaker Branch Breaker Main Breaker Branch Breaker
Series
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
HED4 100 (1P) ED2, ED4 1 120 15-100 QP, BQ, BL, 1 120/240 15-70
QP, BQ, BL, 1 120/240 15-70 QPH, BQH, BLH, 2 120/240 15-125
QPH, BQH, BLH, 2 240 15-125 HQP, HBQ, HBL 3 240 15-100
HQP, HBQ, HBL, 3 240 15-100 QAF2, BAF2, QAF, BQAF,
QAF2, BAF2, QAF, BQAF, BAF, QAFH2, BAFH2,
BAF, QAFH2, BAFH2, HQAF2, HBAF2, QAFH,
HQAF2, HBAF2, QAFH, 1 120 15-20
1 120 15-20 BQAFH, BAFH, QFGA2,
BQAFH, BAFH, QFGA2, BFGA2 HQFGA2, HBF-
BFGA2 HQFGA2, HBF- GA2, QFGAH2, BFGAH2
GA2, QFGAH2, BFGAH2 QAF, BAF, QAFH, BAFH 2 120/240 15-20
QAF, BAF, QAFH, BAFH 2 120/240 15-20 QE, BE, BLE, QPHF,
HED4,
QEH,BLEH, QE, BE, BQHF, BLHF, QPF, BQF,
HED6
QPHF,BQHF, BLHF, QPF, HFD6, BLF, QEH, BLEH, QPF2, 1 120 15-30
BLF, BQF, BLE, QPF2, 1 120 15-30 HFXD6 BLF2, HQPF2, HBLF2,
BLF2, QPHF2, BLHF2, QPHF2, BLHF2
HQPF2, HBLF2 QPF, BLF, BLE, BLEH,
QEH, BLEH, QPHF, QE, 2 120/240 15-60
125 2 120/240 15-60 QPHF, BLHF, QEH, QE
BLHF,QPF,BLF, BLE ED4 1 120 15-100
(2P, 3P)
ED2 1,2,3 120/240 15-100 ED4, ED6 2,3 240 15-125
ED4 1 120 15-100 FD6-A, FXD6-A 2,3 240 70-250
ED4, ED6 2,3 240 15-125 QJ2, QJH2, QJ2H 2,3 240 60-225
QT 1,2 120/240 15-40 HQPP, QPPH, QPP 2 120/240 125-225
QAF2, QAFH2, QAF, QR2, QRH2, HQR2 2,3 240 100-250
BQAF, BAF, BAFH2, QT 1,2 120/240 15-40
HQAF2, HBAF2, QAFH, NDGA, NDGB 2, 3 240 50-150
1 120 15-20
BQAFH, BAFH, QFGA2, NFGA, NFGB 2, 3 240 70-250
BFGA2 HQFGA2, HBF- ED4, ED6 1 240 15-100
NGB, GA2, QFGAH2, BFGAH2
HGB, ED4, ED6 2,3 240 15-125
QAF, BAF, QAFH, BAFH 2 120/240 15-20
LBG NFGA, NFGB 2, 3 240 70-250
QPF,BQF,BLF, QPHF,
QAF2, BAF2, QAFH2,
BQHF, BLHF, QPF2, BLF2,
1 120 15-30 BAFH2, HQAF2, HBAF2,
QPHF2, BLHF2, HQPF2,
QFGA2, BFGA2 HQFGA2, 1 120 15-20
HBLF2 HFGA,
250 HBFGA2, QFGAH2,
QPF, BLF 2 120/240 15-60 HFGB
(2P, 3P) BFGAH2
NGB, 1 120 15-70 QPF2, BLF2, HQPF2,
QP, BQ, BL, QPH, BQH, 1 120 15-30
HGB, 2 120/240 15-125 HBLF2, QPHF2, BLHF2
BLH, HQP, HBQ,HBL
LBG 3 240 15-100
QR2, QRH2, HQR2 2,3 240 100-250
ED4, ED6 1 240 15-100
HDGA, 150 FD6, FXD6 2, 3 240 70-250
ED4, ED6 2,3 240 15-125
HDGB (2P, 3P) FD6-A, FXD6-A 2, 3 240 70-250
NDGA, NDGB 2,3 240 50-150
1 120/240 15-70
QP, BQ, BL, QPH, BQH, 1 120/240 15-70 QP, BQ, BL 2 120/240 15-125
100000
100000 BLH, HQP, HBQ, HBL 2 120/240 15-125
(cont.) 3 240 15-100
HQPP, QPPH, QPP 2 120/240 125-225 QT 1,2 120/240 15-50
QAF2, BAF2, QAF, BQAF, QFGA2, BFGA2, QAF2,
BAF, QAFH2, BAFH2, 1 120 15-20
BAF2, QAF, BAF
HQAF2, HBAF2, QAFH,
1 120 15-20 QAF, BAF 2 120/240 15-20
BQAFH, BAFH, QFGA2,
QPF2, BLF2, QPF, BQF,
BFGA2 HQFGA2, HBF- 1 120 15-30
BLF, QE, BLE, BE
GA2, QFGAH2, BFGAH2
7

225 QPF, BLF, QE, BLE 2 120/240 15-60


HQPPH QAF, BAF, QAFH, BAFH 2 120/240 15-20
(2P) 1 120/240 15-70
QEH, BLEH, QE, BE,
QPH, BQH, BLH 2 120/240 15-125
QPHF, BQHF, BLHF, QPF,
MOLDED CASE
CIRCUIT BREAKERS

3 240 15-100
BQF, BLF, BLE, QPF2, 1 120 15-30
HQR2H QFGAH2, BFGAH2,
BLF2, QPFH2, BLHF2,
QAFH2, BAFH2, HQFGA2,
HQPF2, HBLF2 1 120 15-20
HBFGA2, HQAF2, HBAF2,
QE, QEH, BLEH,
2 120/240 15-60 QAFH, BAFH
QPHF,BLHF,QPF,BLF,BLE
QAFH, BAFH 2 120/240 15-20
QR2, QRH2, HQR2 2 120/240 100-225
QPHF, BLHF, QPHF2,
QT 1,2 120/240 15-40
BLHF2, QEH, BLEH, 1 120 15-30
15-25
QP, BP, QL 1 120/240 HQPF2, HBLF2
35-70
QEH, BLEH, QPHF, BLHF 2 120/240 15-60
15-25
2 120/240 1 120/240 15-70
35-125
HQP, HBQ, HBL 2 120/240 15-125
3 240 15-100
3 240 15-100
QR2, QRH2, HQR2 2,3 240 100-225
QS, QSH, QSHH, HQS 2 120/240 100-225
1 120/240 15-70
QPH, BQH, BLH, HQP, QR2, QRH2, HQR2 2,3 240 100-250
2 120/240 15-125
HBQ ,HBL ED4 1 120 15-100
3 240 15-100
ED4, ED6 2, 3 240 15-125
QAF2, BAF2, QAF, BQAF,
QAF2, BAF2, QAFH2,
BAF, QAFH2, BAFH2,
225 BAFH2, HQAF2, HBAF2,
HQAF2, HBAF2, QAFH,
HQJ2H 1 120 15-20 QFGA2, BFGA2 HQFGA2, 1 120 15-20
(2P, 3P) BQAFH, BAFH, QFGA2,
HBFGA2, QFGAH2,
BFGA2 HQFGA2, HBF-
BFGAH2
GA2, QFGAH2, BFGAH2
HJD6-A, 400 QPF2, BLF2, HQPF2,
QAF, BAF, QAFH, QAFH 2 120/240 15-20 1 120 15-30
HJXD6-A (2P, 3P) HBLF2, QPHF2, BLHF2
QEH, BLEH, QE, BE,
QR2, QRH2, HQR2 2,3 240 100-250
QPHF, BQHF, BLHF, QPF,
BQF, BLF, BLE, QPF2, 1 120 15-30 FD6-A, FXD6-A 2, 3 240 70-250
BLF2, HQPF2, HBLF2, JD6-A, JXD6-A
2, 3 240 200-400
QPHF2, BLHF2 JXD2-A, SJD6-A
QEH, BLEH, QPHF, BLE, NDGA, NDGB 2, 3 240 50-150
2 120/240 15-60 NFGA, NFGB 2, 3 240 70-250
BLHF, QE, QPF, BLF
QT 1 120/240 15-50 NJGA, NJJA 2, 3 240 200-400

7-216 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/06/18

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

240V Breaker Series Ratings (continued) 240V Breaker Series Ratings (continued)
Series Main Breaker Branch Breaker Main Breaker Branch Breaker
Series
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
ED4, ED6 1 240 15-100 QR2, QRH2, HQR2 2,3 240 100-250
ED4, ED6 2,3 240 15-125 SHLD6,
600 NDGA, NDGB 2, 3 240 50-150
QAF2, BAF2, QAFH2, SHLD6-A
(3P) NFGA, NFGB 2, 3 240 70-250
BAFH2, HQAF2, HBAF2, SHLD6-B
(cont.) NJGA, NJJA 2, 3 240 200-400
QFGA2, BFGA2 HQFGA2, 1 120 15-20 (cont.)
NLGA, NLGB 2, 3 240 400-600
HBFGA2, QFGAH2, ED4, ED6 1 240 15-100
BFGAH2 ED4, ED6 2,3 240 15-125
400 QPF2, BLF2, HQPF2, NFGA, NFGB 2, 3 240 70-250
HJGA 1 120 15-30
(2P, 3P) HBLF2, QPHF2, BLHF2 FD6, FXD6 2, 3 240 70-250
NFGA, NFGB 2, 3 240 70-250 FD6-A, FXD6-A 2, 3 240 70-250
FD6, FXD6 2, 3 240 70-250 NJGA, NJJA 2, 3 240 200-400
FD6-A, FXD6-A 2, 3 240 70-250 JD6, JXD6 2, 3 240 200-400
QR2, QRH2, HQR2 2,3 240 100-250 JD6-A, JXD6-A 2, 3 240 200-400
NJGA, NJJA 2, 3 240 200-400 NLGA, NLGB 2, 3 240 400-600
JD6, JXD6 2, 3 240 200-400 LD6, LD6-A 2, 3 240 200-600
JD6-A, JXD6-A 2, 3 240 200-400 LXD6, LXD6-A 2, 3 240 450-600
ED4 1 120 15-100 HMG
NMG 2, 3 240 600-800
ED4, ED6 2, 3 240 15-125 QAF2, BAF2, QAFH2,
FD6-A, FXD6-A 2, 3 240 70-250 BAFH2, HQAF2, HBAF2,
JD6-A, JXD6-A QFGA2, BFGA2 HQFGA2, 1 120 15-20
2, 3 240 200-400
JXD2-A, SJD6-A, SJD6-B HBFGA2, QFGAH2,
QAF2, BAF2, QAFH2, BFGAH2
BAFH2, HQAF2, HBAF2, QPF2, BLF2, HQPF2,
SHJD6, 1 120 15-30
QFGA2, BFGA2 HQFGA2, 1 120 15-20 HBLF2, QPHF2, BLHF2
SHJD6-A, 400 (3P)
HBFGA2, QFGAH2, QR2, QRH2, HQR2 2,3 240 100-250
SHJD6-B
BFGAH2 LMD6, LMXD6 2, 3 240 600-800
QPF2, BLF2, HQPF2, MD6, MXD6 2, 3 240 400-800
1 120 15-30 800
HBLF2, QPHF2, BLHF2 NDGA, NDGB 2, 3 240 50-150
QR2, QRH2, HQR2 2,3 240 100-250 (2P, 3P)
NFGA, NFGB 2, 3 240 70-250
NDGA, NDGB 2, 3 240 50-150 NJGA, NJJA 2, 3 240 200-400
NFGA, NFGB 2, 3 240 70-250 NLGA, NLGB 2, 3 240 400-600
NJGA, NJJA 2, 3 240 200-400 NMG 2, 3 240 600-800
ED4 1 120 15-100 ED4 1 120 15-100
ED4, ED6 2,3 240 15-125 ED4, ED6 2,3 240 15-125
QAF2, BAF2, QAFH2, FD6-A, FXD6-A 2,3 240 70-250
BAFH2, HQAF2, HBAF2, JD6-A, JXD6-A,
QFGA2, BFGA2 HQFGA2, 1 120 15-20 2,3 240 200-400
JXD2-A, SJD6-A
HBFGA2, QFGAH2, LD6-A 2,3 240 200-600
BFGAH2 HMD6,
HMXD6 LXD6-A 2,3 240 450-600
QPF2, BLF2, HQPF2, QAF2, BAF2, QAFH2,
1 120 15-30
HBLF2, QPHF2, BLHF2 BAFH2, HQAF2, HBAF2,
HLD6-A, FD6-A, FXD6-A 2,3 240 70-250 QFGA2, BFGA2 HQFGA2, 1 120 15-20
100000 HLXD6-A JD6-A, JXD6-A, JXD2-A, HBFGA2, QFGAH2,
2,3 240 200-400 100000
(cont.) SJD6-A, SJD6-B BFGAH2
(cont.)
LD6-A 2,3 240 200-600 QPF2, BLF2, HQPF2,
LXD6-A 2,3 240 450-600 1 120 15-30
HBLF2, QPHF2, BLHF2
SLD6-A, SLD6-B 3 240 300-600 QR2, QRH2, HQR2 2,3 240 100-250
QR2, QRH2, HQR2 2,3 240 100-250 SLD6-A, SLD6-B 3 240 300-600

7
NDGA, NDGB 2, 3 240 50-150 MD6, MXD6 2,3 240 500-800
NFGA, NFGB 2, 3 240 70-250 SMD6, SMD6-B 3 240 600-800
NJGA, NJJA 2, 3 240 200-400 NDGA, NDGB 2, 3 240 50-150
600

CIRCUIT BREAKERS
MOLDED CASE
NLGA, NLGB 2, 3 240 400-600 NFGA, NFGB 2, 3 240 70-250
(2P, 3P)
ED4, ED6 1 240 15-100 NJGA, NJJA 2, 3 240 200-400
ED4, ED6 2,3 240 15-125 NLGA, NLGB 2, 3 240 400-600
NFGA, NFGB 2, 3 240 70-250 NMG 2, 3 240 600-800
FD6, FXD6 2, 3 240 70-250 ED4 1 120 15-100
FD6-A, FXD6-A 2, 3 240 70-250 ED4, ED6 2,3 240 15-125
NJGA, NJJA 2, 3 240 200-400 FD6-A, FXD6-A 2,3 240 70-250
JD6, JXD6 2, 3 240 200-400 JD6-A, JXD6-A,
JD6-A, JXD6-A 2, 3 240 200-400 2,3 240 200-400
JXD2-A
HLGA, NLGA, NLGB 2, 3 240 400-600 SJD6-A, SJD6-B 2,3 240 200-400
HLGB QAF2, BAF2, QAFH2, SHMD6, 800 LD6-A 2,3 240 200-600
BAFH2, HQAF2, HBAF2, SHMD6-B (3P) LXD6-A 2,3 240 450-600
QFGA2, BFGA2 HQFGA2, 1 120 15-20 QAF2, BAF2, QAFH2,
HBFGA2, QFGAH2, BAFH2, HQAF2, HBAF2,
BFGAH2 QFGA2, BFGA2 HQFGA2, 1 120 15-20
QPF2, BLF2, HQPF2, HBFGA2, QFGAH2,
1 120 15-30
HBLF2, QPHF2, BLHF2 BFGAH2
QR2, QRH2, HQR2 2,3 240 100-250 QPF2, BLF2, HQPF2,
LD6, LD6-A 2, 3 240 200-600 1 120 15-30
HBLF2, QPHF2, BLHF2
LXD6, LXD6-A 2, 3 240 450-600 QR2, QRH2, HQR2 2,3 240 100-250
ED4 1 120 15-100
SLD6-A, SLD6-B 3 240 300-600
ED4, ED6 2,3 240 15-125
MD6, MXD6, SMD6,
FD6-A, FXD6-A 2,3 240 70-250 2,3 240 500-800
SMD6-B
JD6-A, JXD6-A, JXD2-A,
2,3 240 200-400 ED4, ED6 1 240 15-100
SJD6-A, SJD6-B
ED4, ED6 2,3 240 15-125
LD6-A 2,3 240 200-600
NFGA, NFGB 2, 3 240 70-250
SHLD6, LXD6-A 2,3 240 450-600
600 FD6, FXD6 2, 3 240 70-250
SHLD6-A, SLD6-A, SLD6-B 3 240 300-600
(3P) FD6-A, FXD6-A 2, 3 240 70-250
SHLD6-B 1200
QAF2, BAF2, QAFH2, HNG NJGA, NJJA 2, 3 240 200-400
BAFH2, HQAF2, HBAF2, (2P, 3P)
QFGA2, BFGA2 HQFGA2, 1 120 15-20 JD6, JXD6 2, 3 240 200-400
HBFGA2, QFGAH2, JD6-A, JXD6-A 2, 3 240 200-400
BFGAH2 NLGA, NLGB 2, 3 240 400-600
QPF2, BLF2, HQPF2, LD6, LD6-A 2, 3 240 200-600
1 120 15-30
HBLF2, QPHF2, BLHF2 LXD6, LXD6-A 2, 3 240 450-600

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-217


Revised on 05/31/19

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

240V Breaker Series Ratings (continued) 240V Breaker Series Ratings (continued)
Series Main Breaker Branch Breaker Series Main Breaker Branch Breaker
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
QAF2, BAF2, QAFH2, ED4 1 240 15-100
BAFH2, HQAF2, HBAF2, ED4, ED6 2,3 240 15-125
QFGA2, BFGA2 HQFGA2, 1 120 15-20 JD6-A, JXD6-A
HBFGA2, QFGAH2, 2,3 240 200-400
JXD2-A
BFGAH2 SJD6-A, SJD6-B 3 240 200-400
HNG QPF2, BLF2, HQPF2, LD6-A 2,3 240 200-600
1 120 15-30
(cont.) HBLF2, QPHF2, BLHF2 LXD6-A 2,3 240 450-600
QR2, QRH2, HQR2 2,3 240 100-250 SLD6-A, SLD6-B 3 240 300-600
NMG 2, 3 240 600-800 MD6, MXD6, 2,3 240 500-800
LMD6, LMXD6 2, 3 240 600-800 HPD6, SMD6, SMD6-B 3 240 600-800
NNG 2, 3 240 800-1200 HPXD6, ND6, NXD6,
ND6, NXD6 2,3 240 600-1200 2,3 240 500-1200
SHPD6 SND6, SND6-B
ED4 1 240 15-100 SHPD6-B PD6, PXD6 2,3 240 1200-1600
ED4, ED6 2,3 240 15-125 SPD6, SPD6-B 3 240 1400-1600
FD6-A, FXD6-A 2,3 240 70-250 QR2, QRH2, HQR2 2,3 240 100-250
JD6-A, JXD6-A, NDGA, NDGB 2, 3 240 50-150
2,3 240 200-400
JXD2-A, SJD6-A NFGA, NFGB 2, 3 240 70-250
LD6-A 2,3 240 200-600 NJGA, NJJA 2, 3 240 200-400
1200 LXD6-A 2,3 240 450-600 NLGA, NLGB 2, 3 240 400-600
(2P, 3P) SLD6-A, SLD6-B 3 240 300-600
NMG 2, 3 240 600-800
MD6, MXD6,
2,3 240 500-800 NNG 2, 3 240 800-1200
SMD6 1600 NPG 2, 3 240 1200-1600
ND6, NXD6, (3P)
2,3 240 500-1200 ED4 1 240 15-100
SND6, SND6-B
HND6, QAF2, BAF2, QAFH2, ED4, ED6 2,3 240 15-125
HNXD6 BAFH2, HQAF2, HBAF2, FD6-A, FXD6-A 2,3 240 70-250
QFGA2, BFGA2 HQFGA2, 1 120 15-20 JD6-A, JXD6-A, JXD2-A 2,3 240 200-400
HBFGA2, QFGAH2, SJD6-A, SJD6-B 3 240 200-400
BFGAH2 LD6-A 2,3 240 200-600
QPF2, BLF2, HQPF2, LXD6-A 2,3 240 450-600
1 120 15-30
HBLF2, QPHF2, BLHF2 SLD6-A, SLD6-B 3 240 300-600
QR2, QRH2, HQR2 2,3 240 100-250 MD6, MXD6, 2,3 240 500-800
NDGA, NDGB 2, 3 240 50-150 SMD6, SMD6-B 3 240 500-800
NFGA, NFGB 2, 3 240 70-250 100000 SHPD6, ND6, NXD6 2,3 240 500-1200
NJGA, NJJA 2, 3 240 200-400 (cont.) SHPD6-B SND6, SND6-B 3 240 500-1200
NLGA, NLGB 2, 3 240 400-600 NPG, PD6, PXD6 2,3 240 1200-1600
NMG 2, 3 240 600-800 SPD6, SPD6-B 3 240 1400-1600
NNG 2, 3 240 800-1200 NDGA, NDGB 2, 3 240 50-150
ED4 1 240 15-100 NFGA, NFGB 2, 3 240 70-250
ED4, ED6 2,3 240 15-125 NJGA, NJJA 2, 3 240 200-400
FD6-A, FXD6-A 2,3 240 70-250 NLGA 2, 3 240 400-600
JD6-A, JXD6-A, NMG 2, 3 240 600-800
2,3 240 200-400
JXD2-A, SJD6-A NNG 2, 3 240 800-1200
100000 LD6-A 2,3 240 200-600
(cont.) NPG 2, 3 240 1200-1600
LXD6-A 2,3 240 450-600 ED4 1 240 15-100
SLD6-A, SLD6-B 3 240 300-600
ED4, ED6 2,3 240 15-125
MD6, MXD6,
2,3 240 500-800 JD6-A, JXD6-A, JXD2-A 2,3 240 200-400
SMD6, SMD6-B
7

SJD6-A, SJD6-B 3 240 200-400


ND6, NXD6,
2,3 240 500-1200 LD6-A 2,3 240 200-600
SND6, SND6-B
QAF2, BAF2, QAFH2, LXD6-A 2,3 240 450-600
SHND6, 1200
MOLDED CASE
CIRCUIT BREAKERS

BAFH2, HQAF2, HBAF2, SLD6-A, SLD6-B 3 240 300-600


SHND6-B (3P) MD6,MXD6 2,3 240 500-800
QFGA2, BFGA2 HQFGA2, 1 120 15-20
HBFGA2, QFGAH2, SMD6, SMD6-B 3 240 500-800
BFGAH2 ND6, NXD6, 2,3 240 500-1200
QPF2, BLF2, HQPF2, HRD6, 2000 SND6, SND6-B 3 240 500-1200
1 120 15-30 HRXD6 (3P)
HBLF2, QPHF2, BLHF2 PD6, PXD6 2,3 240 1200-1600
QR2, QRH2, HQR2 2,3 240 100-250 SPD6, SPD6-B 3 240 1200-1600
NDGA, NDGB 2, 3 240 50-150 RD6, RXD6 2,3 240 1600-2000
NFGA, NFGB 2, 3 240 70-250 QR2, QRH2, HQR2 2,3 240 100-250
NDGA, NDGB 2,3 240 50-150
NJGA, NJJA 2, 3 240 200-400
NFGA, NFGB 2,3 240 70-250
NLGA, NLGB 2, 3 240 400-600
NJGA, NJJA 2,3 240 200-400
NMG 2, 3 240 600-800 NLGA, NLGB 2,3 240 400-600
NNG 2, 3 240 800-1200 NMG 2,3 240 600-800
ED4, ED6 1 240 15-100 NNG 2,3 240 800-1200
ED4, ED6 2,3 240 15-125 NPG 2,3 240 1200-1600
NFGA, NFGB 2, 3 240 70-250 QP, BQ, BL 1 120/240 15-70
FD6, FXD6 2, 3 240 70-250 QPH, BQH, BLH, 2 120/240 15-125
HQP, HBQ, HBL 3 240 15-100
FD6-A, FXD6-A 2, 3 240 70-250 QAF2, BAF2, QAF, BQAF,
NJGA, NJJA 2, 3 240 200-400 BAF, QAFH2, BAFH2,
JD6, JXD6 2, 3 240 200-400 HQAF2, HBAF2, QAFH,
1 120 15-20
JD6-A, JXD6-A 2, 3 240 200-400 BQAFH, BAFH, HQFGA2,
NLGA, NLGB 2, 3 240 400-600 HBFGA2, QFGA2, QF-
1600 GAH2, BFGAH2
HPG LD6, LD6-A 2, 3 240 200-600
(2P, 3P) 125 BAF, QAF, BAFH, QAFH 2 120/240 15-20
LXD6, LXD6-A 2, 3 240 450-600 200000 CED6
(2P, 3P) QPHF, BQHF, BLHF,QPF,
QR2, QRH2, HQR2 2,3 240 100-250 BQF, BLF, QEH, QE, BE, 1 120 15-30
NMG 2, 3 240 600-800 BLEH, BLE
LMD6, LMXD6 2, 3 240 600-800 QEH, BLEH, QAHF, QE,
QPHF, BLHF, QPF, 2 120/240 15-60
MD6, MXD6 2, 3 240 400-800
BLE, BLF
NNG 2, 3 240 800-1200 ED4, HED4 1 120 15-100
ND6, NXD6 2, 3 240 600-1200 ED4, ED6, HED4, HED6 2,3 240 15-125
NPG 2, 3 240 1200-1600 QT 1,2 120/240 15-40
PD6, PXD6 2, 3 240 1200-1600 NGB,HGB,LBG 1,2,3 240 15-125

7-218 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/19

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

240V Breaker Series Ratings (continued) 240V Breaker Series Ratings (continued)

Series Main Breaker Branch Breaker Series Main Breaker Branch Breaker
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
NGB,HGB,LBG 1,2,3 240 15-125 LXD6-A, HJXD6-A 2,3 240 450-600
LDGA, 150
NDGA, NDGB, HDGA, QT 1,2 120/240 15-30
LDGB (2P, 3P) 2, 3 240 50-150
HDGB NGB,HGB,LBG 1,2,3 240 15-125
1 120/240 15-70 NDGA, NDGB, HDGA,
QP, BQ, BL, QPH, BQH, 2-3 240 50-150
2 120/240 15-125 CLD6-A HDGB
BLH, HQP, HBQ, HBL
3 240 15-100 (cont.) NFGA, NFGB, HFGA,
QAF2, BAF2, QAF, BQAF, 240 70-250
HFGB
BAF, QAFH2, BAFH2,
NJGA, HJGA, NJJA 240 200-400
HQAF2, HBAF2, QAFH,
1 120 15-20 NLGA, HLGA, NLGB,
BQAFH, BAFH, HQFGA2, 600 240 400-600
HLGB
HBFGA2, QFGA2, QF- (2P, 3P
GAH2, BFGAH2 NGB,HGB,LBG 1,2,3 240 15-125
BAF, QAF, BAFH, QAFH 2 120/240 15-20 NDGA, NDGB, HDGA,
2, 3 240 50-150
QPHF, BQHF, BLHF, QE, HDGB
BE, BLE, QPF, BQF, BLF, 1 120 15-30 NFGA, NFGB, HFGA,
LLGA, 240 70-250
QEH, BLEH, QAF, BAF HFGB
LLGB
QPHF, BLHF, QE, BLE, HFD6, HFXD6 240 70-250
QPF, BLF, QEH, BLEH, 2 120/240 15-60 NJGA, HJGA, NJJA 240 200-400
CFD6 QAF, BAF NLGA, HLGA, NLGB,
240 400-600
ED2 1,2,3 120/240 15-100 HLGB
250 HED4, ED4 1 120 15-100 ED4 1 240 15
(2P, 3P) ED4, ED6, ED4, ED6,
2,3 240 15-125 2,3 240 15-125
HED4, HED6 HED4, HED6
FD6-A, FXD6-A FD6-A, FXD6-A,
2,3 240 70-250 2,3 240 70-250
HFD6, HFXD6 HFD6, HFXD6
QJ2H, QJH2, QJ2 2,3 240 60-225 JXD2-A, JD6-A,
QPPH, QPP 2 120/240 125-225 JXD6-A, HJD6-A 2,3 240 200-400
QT 1,2 120/240 15-40 HJXD6-A
NGB,HGB,LBG 1,2,3 240 15-125 LD6-A, HLD6-A 2,3 240 200-600
NDGA, NDGB, HDGA, LXD6-A, HLXD6-A 2,3 240 450-600
2, 3 240 50-150 CMD6
HDGB MD6, MXD6,
NFGA, NFGB, HFGA, 2,3 240 500-800
2, 3 240 70-250 HMD6, HMXD6
HFGB NDGA, NDGB, HDGA,
NGB,HGB,LBG 1,2,3 240 15-125 2,3 240 50-150
HDGB
NDGA, NDGB, HDGA, NFGA, NFGB, HFGA,
2, 3 240 50-150 2,3 240 70-250
LFGA, HDGB 800 HFGB
LFGB NFGA, NFGB, HFGA, (2P, 3P
240 70-250 NJGA, HJGA, NJJA 2,3 240 200-400
HFGB
NLGA, HLGA, NLGB,
HFD6, HFXD6 240 70-250 2,3 240 400-600
HLGB
QPH, BQH, BLH, 2 120/240 100-125
NMG, HMG 2,3 240 600-800
HQP, HBQ, HBL 3 240 100
HFD6, HFXD6 2,3 240 70-250
ED4, ED6 2,3 240 15-125
200000 200000 MD6, MXD6 2,3 240 400-800
FD6-A, FXD6-A
(cont.) 2,3 240 70-250 (cont.) HMD6, HMXD6 2,3 240 400-800
HFD6, HFXD6
JXD2-A, JD6-A, NDGA, NDGB, HDGA,
2,3 240 50-150
JXD6-A, HJD6-A, 2,3 240 200-400 HDGB
CJD6-A HJXD6-A LMG NFGA, NFGB, HFGA,
2,3 240 70-250
QT 1,2 120/240 15-30 HFGB

7
NGB,HGB,LBG 1,2,3 240 15-125 NJGA, HJGA, NJJA 2,3 240 200-400
NDGA, NDGB, HDGA, NLGA, HLGA, NLGB,
2, 3 240 50-150 2,3 240 400-600
HDGB HLGB

CIRCUIT BREAKERS
MOLDED CASE
NFGA, NFGB, HFGA, NMG, HMG 2,3 240 600-800
240 70-250
HFGB MD6, MXD6,
400 2,3 240 500-800
NJGA, HJGA, NJJA 240 200-400 HMD6, HMXD6
(2P, 3P)
NGB,HGB,LBG 1,2,3 240 15-125 NDGA, NDGB, HDGA,
2,3 240 50-150
NDGA, NDGB, HDGA, HDGB
2, 3 240 50-150 SCMD6,
HDGB NFGA, NFGB, HFGA,
LJGA NFGA, NFGB, HFGA, SCMD6-A 800 (3P) 2,3 240 70-250
240 70-250 HFGB
HFGB SCMD6-B
NJGA, HJGA, NJJA 2,3 240 200-400
HFD6, HFXD6 240 70-250 NLGA, HLGA, NLGB,
NJGA, HJGA, NJJA 240 200-400 2,3 240 400-600
HLGB
FD6-A, FXD6-A 2 NMG, HMG 2,3 240 600-800
240 70-250
HFD6, HFXD6 3 ED4, ED6 1 240 15
NDGA, NDGB, HDGA, ED4, ED6,
HHJD6, 2, 3 240 50-150 2,3 240 15-125
HDGB HED4, HED6
HHJXD6
NFGA, NFGB, HFGA,
240 70-250 FD6-A, FXD6-A,
HFGB 2,3 240 70-250
HFD6, HFXD6
NJGA, HJGA, NJJA 240 200-400
JXD2-A, JD6-A,
FD6-A, FXD6-A
2, 3 240 70-250 JXD6-A, HJD6-A, 2,3 240 200-400
HFD6, HFXD6
HJXD6-A
NDGA, NDGB, HDGA,
2, 3 240 50-150 LD6-A, HLD6-A 2,3 240 200-600
HDGB
HHLD6, LXD6-A, HLXD6-A 2,3 240 450-600
NFGA, NFGB, HFGA,
HHLXD6 240 70-250 1200 MD6, MXD6,
HFGB CND6-A 2,3 240 500-800
NJGA, HJGA, NJJA 240 200-400 (2P, 3P) HMD6, HMXD6
NLGA, HLGA, NLGB, ND6, NXD6, SHND6,
600 240 400-600 2,3 240 500-1200
HLGB HND6,HNXD6
(2P, 3P) NDGA, NDGB, HDGA,
QPH, BQH, BLH 2 120/240 100-125 2,3 240 50-150
HQP, HBQ, HBL 3 240 100 HDGB
ED4, ED6 2,3 240 15-125 NFGA, NFGB, HFGA,
2,3 240 70-250
FD6-A, FXD6-A HFD6, HFGB
CLD6-A 2,3 240 70-250 NJGA, HJGA, NJJA 2,3 240 200-400
HFXD6
JXD2-A, JD6-A, JXD6-A, NLGA, HLGA, NLGB,
2,3 240 200-400 2,3 240 400-600
HJD6-A, HJXD6-A HLGB
LD6-A, HLD6-A 2,3 240 200-600 NMG, HMG 2,3 240 600-800

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-219


Revised on 05/31/19

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

240V Breaker Series Ratings (continued) 480V Breaker Series Ratings


Main Breaker Branch Breaker Series Main Breaker Branch Breaker
Series
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
HFD6, HFXD6 2,3 240 70-250 125
18,000 ED4 BQD, CQD 1,2,3 277/480 15-100
MD6, MXD6 (2 & 3P)
2,3 240 400-800 ED6 BQD, CQD 1,2,3 277/480 15-100
HMD6, HMXD6
ND6,NXD6,HND6,HNXD6 2,3 240 600-1200 NGB, 1 277 15-100
NDGA, NDGB, HDGA, HGB, BQD, CQD 2 277/480 15-100
2,3 240 50-150 125
1200 HDGB 25,000 LBG 3 277/480 15-100
LNG (2P & 3P)
(2P, 3P) NFGA, NFGB, HFGA, BQD, CQD 1,2,3 277/480 15-100
2,3 240 70-250 HED6 ED4 1 277 15-100
HFGB
NJGA, HJGA, NJJA 2,3 240 200-400 ED4, ED6 2,3 480 15-125
NLGA, HLGA, NLGB, 1 277 15-125
2,3 240 400-600 FD6-A, 250
HLGB NGB,HGB,LBG 2 277/480 15-125
FXD6-A (2P & 3P)
NMG, HMG 2,3 240 600-800 3 277/480 15-125
35,000
MD6, HMD6, 1 277 15-125
2,3 240 400-800 JD6-A, 400
HMXD6, MXD6, MXD6 NGB,HGB,LBG 2 277/480 15-125
JXD6-A (2P & 3P)
SHMD6, SMD6, 3 277/480 15-125
2,3 240 400-800 BQD, CQD 1,2,3 277/480 15-100
SHMD6-B, SMD6-B 125
SCND6-A, 1200 HED4 ED4 1 277 15-100
NMG, HMG 2,3 240 600-800 (2P & 3P)
SCND6-B (3P) ED4, ED6 2,3 480 15-125
ND6, HND6, NXD6, 42,000
2,3 240 500-1200 1 277 15-125
HNXD6 HJD6-A, 400
SHND6, SND6, NGB,HGB,LBG 2 277/480 15-125
3 240 500-1200 HJXD6-A (2P & 3P)
SHND6-B, SND6-B 3 277/480 15-125
NDGA, NDGB, HNDGA, 1 277 15-125
2,3 240 50-150 HFD6, 250
NDGB NGB,HGB,LBG 2 277/480 15-125
HFXD6 (2P & 3P)
NFGA, NFGB, HFGA, 3 277/480 15-125
2,3 240 70-250 HJD6-A, 400
SCND6-A, 1200 HFGB HED4 2,3 480 15-50
SCND6-B (2P, 3P) NJGA, HJGA, NJJA 2,3 240 200-400 HJXD6-A, (2P & 3P)
NLGA, HLGA, NLGB, HLD6-A, 600
2,3 240 400-600 HED4 2,3 480 15-50
HLGB HLXD6-A (2P & 3P)
NMG, HMG 2,3 240 600-800 FD6-A, FXD6-A 2,3 480 70-250
FD6-A, FXD6-A, JD6-A,JXD6-A 2,3 480 200-400
2,3 240 70-250 SJD6-A, SJD6-B 3 480 200-400
HFD6, HFXD6
200000 LD6-A 2,3 480 200-600
JXD2-A, JD6-A,
(cont.) LXD6-A 2,3 480 450-600
JXD6-A, HJD6-A, 2,3 240 200-400 MD6, 800
HJXD6-A SLD6-A, SLD6-B 3 480 400-600
MXD6 (2P & 3P)
LD6-A, HLD6-A 2,3 240 200-600 NDGA, NDGB 2,3 480 50-150
LXD6-A, HLXD6-A 2,3 240 450-600 NFGA, NFGB 2,3 480 70-250
MD6, MXD6, HMD6, NJGA 2,3 480 250-400
2,3 240 500-800 NLGA, NLGB 2,3 480 400-600
HMXD6
1600 NMG 2,3 480 600-800
CPD6 ND6, NXD6,
(3P) 2,3 240 500-1200
HND6, HNXD6, SND6 JD6-A, JXD6-A 2,3 480 200-400
NDGA, NDGB, HDGA, SJD6-A, SJD6-B 3 480 200-400
2,3 240 50-150
HDGB LD6-A 2,3 480 200-600
NFGA, NFGB, HFGA, LXD6-A 2,3 480 450-600
2,3 240 70-250
HFGB SLD6-A, SLD6-B 3 480 400-600
SMD6 800
NJGA, HJGA, NJJA 2,3 240 200-400 LMD6, LMXD6 2,3 480 600-800
SMD6-B (3P)
NLGA, HLGA, NLGB, NDGA, NDGB 2,3 480 50-150
2,3 240 400-600
HLGB NFGA, NFGB 2,3 480 70-250
NMG, HMG 2,3 240 600-800 NJGA 2,3 480 250-400
7

MD6,MXD6, NLGA, NLGB 2,3 480 400-600


2,3 240 400-800
HMD6, HMXD6 50,000 NMG 2,3 480 600-800
ND6,NXD6, FD6-A, FXD6-A 2,3 380 70-250
2,3 240 600-1200
HND6, HNXD6
MOLDED CASE
CIRCUIT BREAKERS

JD6-A, JXD6-A 2,3 480 200-400


PD6, PXD6, HPD6 SJD6-A, SJD6-B 3 480 200-400
2,3 240 1000-1600
HPXD6 LD6-A 2,3 480 200-600
NDGA, NDGB, HDGA, LXD6-A 2,3 480 450-600
1600 2,3 240 50-150
LPG HDGB ND6, 1200 SLD6-A, SLD6-B 3 480 400-600
(2P, 3P)
NFGA, NFGB, HFGA, NXD6 (2P & 3P) NDGA, NDGB 2,3 480 50-150
2,3 240 70-250
HFGB NFGA, NFGB 2,3 480 70-250
HFD6, HFXD6 2,3 240 70-250 NJGA 2,3 480 250-400
NJGA, HJGA, NJJA 2,3 240 200-400 NLGA, NLGB 2,3 480 400-600
NLGA, HLGA, NLGB, NMG, LMD6,
2,3 240 400-600 2,3 480 600-800
HLGB LMXD6
NMG, HMG 2,3 240 600-800 JD6-A, JXD6-A 2,3 480 200-400
SJD6-A, SJD6-B 3 480 200-400
LD6-A 2,3 480 200-600
LXD6-A 2,3 480 450-600
SLD6-A, SLD6-B 3 480 400-600
SND6 1200
LMD6, LMXD6 2,3 480 600-800
SND6-B (3P)
NDGA, NDGB 2,3 480 50-150
NFGA, NFGB 2,3 480 70-250
NJGA 2,3 480 250-400
NLGA, NLGB 2,3 480 400-600
NMG 2,3 480 600-800
JD6-A, JXD6-A 2,3 480 200-400
SJD6-A, SJD6-B 3 480 200-400
SPD6, 1600
LD6-A 2,3 480 200-600
SPD6-B (3P)
LXD6-A 2,3 480 450-600
SLD6-A, SLD6-B 3 480 400-600

7-220 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/19

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

480V Breaker Series Ratings (continued) 480V Breaker Series Ratings (continued)
Series Main Breaker Branch Breaker Main Breaker Branch Breaker
Series
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
FD6-A, FXD6-A 2,3 480 70-250 LMD6,LMXD6 2,3 480 600-800
JD6-A, JXD6-A 2,3 480 200-400 MD6,MXD6 2,3 480 400-800
SJD6-A 3 480 200-400 SMD6, SMD6-B 3 480 500-800
LD6-A 2,3 480 200-600 800 NDGA, NDGB,
LXD6-A 2,3 480 450-600 2,3 480 50-150
HMG (2P & 3P) NDGB
SLD6-A, SLD6-B 3 480 400-600 (cont.) NFGA, NFGB 2,3 480 70-250
1600
PD6, PXD6 NDGA, NDGB 2,3 480 50-150 NJGA 2,3 480 250-400
(3P)
NFGA, NFGB 2,3 480 70-250 NLGA, NLGB 2,3 480 400-600
NJGA 2,3 480 250-400 NMG 2,3 480 600-800
NLGA, NLGB 2,3 480 400-600 FD6-A, FXD6-A 2,3 480 70-250
NMG 2,3 480 600-800 JD6-A, JXD6-A 2,3 480 200-400
NNG 2,3 480 800-1200 LD6-A 2,3 480 200-600
50,000 NPG 2,3 480 1200-1600 LXD6-A 2,3 480 450-600
(cont.) FD6-A, FXD6-A 2,3 480 70-250 MD6, MXD6 2,3 480 500-800
JD6-A, JXD6-A 2,3 480 200-400 SMD6, SMD6-B 3 480 500-800
SJD6-A, SJD6-B 3 480 200-400 HND6, LMD6, LMXD6 2,3 480 600-800
LD6-A 2,3 480 200-600 HNXD6 NDGA, NDGB,
LXD6-A 2,3 480 450-600 2,3 480 50-150
NDGB
SLD6-A, SLD6-B 3 480 400-600 NFGA, NFGB 2,3 480 70-250
18-2000
RD6, RXD6 NDGA, NDGB 2,3 480 50-150 NJGA 2,3 480 250-400
(3P)
NFGA, NFGB 2,3 480 70-250 1200 NLGA, NLGB 2,3 480 400-600
NJGA 2,3 480 250-400 (2P & 3P) NMG 2,3 480 600-800
NLGA, NLGB 2,3 480 400-600 NNG 2,3 480 800-1200
NMG 2,3 480 600-800 LMD6,LMXD6 2,3 480 600-800
NNG 2,3 480 800-1200 MD6, MXD6 2,3 480 400-800
NPG 2,3 480 1200-1600 ND6,NXD6 2,3 480 800-1200
HDGA, 150 NDGA, NDGB,
NDGA, NDGB 2,3 480 50-150 2,3 480 50-150
HDGB (2P & 3P) NDGB
BQD, CQD 1,2,3 277/480 15-100 HNG
NFGA, NFGB 2,3 480 70-250
ED4, HED4 1 277 15-100 NJGA 2,3 480 250-400
HFD6,
ED4, ED6, HED4, NLGA, NLGB 2,3 480 400-600
HFXD6 2,3 480 15-125
250 HED6 NMG 2,3 480 600-800
(2P & 3P) NDGA, NDGB 480 50-150 65,000 NNG 2,3 480 800-1200
2,3
NFGA, NFGB 480 70-250 (cont.) FD6-A, FXD6-A 2,3 480 70-250
HFGA, NDGA, NDGB 480 50-150 NDGA, NDGB,
2,3 2,3 480 50-150
HFGB NFGA, NFGB 480 70-250 NDGB
HED4, ED4 1 277 15-100 NFGA, NFGB 2,3 480 70-250
FD6-A, FXD6-A 2,3 480 70-250 HPD6, 1600 NJGA 2,3 480 250-400
HJD6-A, JD6-A, JXD6-A 2,3 480 200-400 HPXD6 (3P)
NLGA, NLGB 2,3 480 400-600
HJXD6-A NDGA, NDGB 2,3 480 50-150
NFGA, NFGB 2,3 480 70-250 NMG 2,3 480 600-800
NJGA 2,3 480 250-400 NNG 2,3 480 800-1200
NDGA, NDGB 2,3 480 50-150 NPG 2,3 480 1200-1600
400
NFGA, NFGB 2,3 480 70-250 LMD6,LMXD6 2,3 480 600-800
(2P & 3P)
NJGA 2,3 480 250-400 MD6, MXD6 2,3 480 400-800
HJGA
1 277 15-125 ND6,NXD6 2,3 480 800-1200
NGB,HGB,LBG 2 277/480 15-125 NDGA, NDGB 2,3 480 50-150
3 277/480 15-125 NFGA, NFGB 2,3 480 70-250
1600

7
1 277 15-125* HPG
HHJD6, (2P & 3P) NJGA 2,3 480 250-400
NGB,HGB,LBG 2 277/480 15-125*
HHJXD6 NLGA, NLGB 2,3 480 400-600
3 277/480 15-125*
NMG 2,3 480 600-800

CIRCUIT BREAKERS
MOLDED CASE
ED4, HED4 1 277 15-100
FD6-A, FXD6-A 2,3 480 70-250 NNG 2,3 480 800-1200
JD6-A, JXD6-A 2,3 480 200-400 NPG 2,3 480 1200-1600
65,000
LD6-A 2,3 480 200-600 FD6-A, FXD6-A 2,3 480 70-250
HLD6-A,
LXD6-A 2,3 480 450-600 JD6-A, JXD6-A 2,3 480 200-400
HLXD6-A
NDGA, NDGB 2,3 480 50-150 LD6-A 2,3 480 200-600
NFGA, NFGB 2,3 480 70-250 LXD6-A 2,3 480 450-600
NJGA 2,3 480 250-400
NDGA, NDGB 2,3 480 50-150
NLGA, NLGB 2,3 480 400-600 HRD6, 18-2000
600 NFGA, NFGB 2,3 480 70-250
(2P & 3P) 1 277 15-125 HRXD6 (3P)
HHLD6, NJGA 2,3 480 250-400
NGB,HGB,LBG 2 277/480 15-125
HHLXD6 NLGA, NLGB 2,3 480 400-600
3 277/480 15-125
1 277 15-125* NMG 2,3 480 600-800
NGB,HGB,LBG 2 277/480 15-125* NNG 2,3 480 800-1200
3 277/480 15-125* NPG 2,3 480 1200-1600
HLGA,
NDGA, NDGB 2,3 480 50-150 1 277 15-125*
HLGB LDGA, 150
NFGA, NFGB 2,3 480 70-250 NGB,HGB,LBG 2 277/480 15-125*
NJGA 2,3 480 250-400 LDGB (2P & 3P)
3 277/480 15-125*
NLGA, NLGB 2,3 480 400-600 1 277/480 15-100
FD6-A, FXD6-A 2,3 480 70-250 CFD6 BQD, CQD
2,3 277/480 15-30
JD6-A, JXD6-A 2,3 480 200-400 1 277 15-125*
LD6-A 2,3 480 200-600 NGB,HGB,LBG 2 277/480 15-125*
LXD6-A 2,3 480 450-600 3 277/480 15-125*
LMD6, LMXD6 2,3 480 600-800 100,000
LFGA, NDGA, NDGB,
250 2,3 480 50-150
HMD6, 800 MD6, MXD6 2,3 480 400-800 LFGB HDGA, HDGB
HMXD6 (2P & 3P) (2P & 3P)
NDGA, NDGB, NFGA, NFGB,
2,3 480 50-150 2,3 480 70-250
NDGB HFGA, HFGB
NFGA, NFGB 2,3 480 70-250 HFD6, HFXD6 2, 3 480 70-250
NJGA 2,3 480 250-400 HHFD6, 1 277 15-125*
NLGA, NLGB 2,3 480 400-600 HHFXD6 NGB,HGB,LBG 2 277/480 15-125*
NMG 2,3 480 600-800 3 277/480 15-125*

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-221


Revised on 05/31/19

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

480V Breaker Series Ratings (continued) 480V Breaker Series Ratings (continued)
Series Main Breaker Branch Breaker Series Main Breaker Branch Breaker
Rating Max. Number Rating Max. Number
kAIR Type Amperes Type of Poles Voltage Amperes kAIR Type Amperes Type of Poles Voltage Amperes
ED4, ED6, HED4, FD6-A, FXD6-A 2,3 480 70-250
1 277 15-100
HED6
HFD6-A, HFXD6-A 2,3 480 70-250
HFD6, HFXD6,
2,3 480 70-250 JD6-A, HJD6-A
FXD6-A, FD6-A 2,3 480 200-400
HHJXD6, JXD6-A, HJXD6-A
NDGA, NDGB,
HHJD6, 2,3 480 50-150 LD6-A, HLD6-A 2,3 480 200-600
HDGA, HDGB
NFGA, NFGB, LXD6-A, HLXD6-A 2,3 480 450-600
2,3 480 70-250
HFGA, HFGB MD6, MXD6
400 2,3 480 500-800
NJGA, HJGA 2,3 480 200-400 HMD6, HMXD6
(2P, 3P) CND6 1200 (3P)
1 277 15-125* ND6, NXD6
CJD6-A NGB,HGB,LBG 2 277/480 15-125* 2,3 480 500-1200
HND6, HNXD6
3 277/480 15-125* NDGA, NDGB,
NDGA, NDGB, 480 50-150
2,3 480 50-150 HDGA, HDGB
HDGA, HDGB NFGA, NFGB,
LJGA NFGA, NFGB, 480 70-250
2,3 480 70-250 HFGA, HFGB 2-3
HFGA, HFGB NJGA, HJGA 480 200-400
HFD6, HFXD6 2,3 480 70-250
NLGA, HLGA,
ED4, ED6, HED4, 480 400-600
1 277 15-100 NLGB, HLGB
HED6
FD6-A, FXD6-A
HFD6, HFXD6, 2,3 480 70-250
2,3 480 70-250 HFD6-A, HFXD6-A
FXD6-A, FD6-A 100,000
HHLD6, NDGA, NDGB,
NDGA, NDGB, (cont.) 2,3 480 50-150
HHLXD6 2,3 480 50-150 HDGA, HDGB
HDGA, HDGB
NFGA, NFGB, CPD6 1600 (3P) NFGA, NFGB,
2,3 480 70-250 2,3 480 70-250
600 HFGA, HFGB
HFGA, HFGB
(2P, 3P) NJGA, HJGA 2,3 480 200-400
NJGA, HJGA 2,3 480 200-400
NDGA, NDGB, NLGA, HLGA,
2,3 480 50-150 2,3 480 400-600
HDGA, HDGB NLGB, HLGB
LLGA, NFGA, NFGB, NDGA, NDGB,
2,3 480 70-250 2,3 480 50-150
LLGB HFGA, HFGB HDGA, HDGB
HFD6, HFXD6 2,3 480 70-250 NFGA, NFGB,
2,3 480 70-250
NJGA , HJGA 2,3 480 200-400 HFGA, HFGB
FD6-A, FXD6-A HFD6, HFXD6 2,3 480 70-250
2,3 480 70-250
HFD6-A, HFXD6-A NJGA, HJGA 2,3 480 200-400
JD6-A, HJD6-A, 1600 NLGA, NLGB,
2,3 480 200-400 LPG (2,3P) 2,3 480 400-600
JXD6-A, HJXD6-A (2P, 3P) HLGA, HLGB
100,000
LD6-A, HLD6-A 2,3 480 200-600 MD6, MXD6, HMD6,
(cont.) 2,3 480 500-800
LXD6-A, HLXD6-A 2,3 480 450-600 HMXD6
MD6, MXD6, HMD6, ND6, NXD6, HND6
800 2,3 480 500-800 2,3 480 500-1200
CMD6 HMXD6 HNXD6
(3P)
NDGA, NDGB, PD6,PXD6, HPD6
2,3 480 50-150 2,3 480 1200-1600
HDGA, HDGB HPXD6
NFGA, NFGB, ED4 1 277 15-100
2,3 480 70-250
HFGA, HFGB
400 HFD6, HFXD6 2,3 480 70-250
NJGA, HJGA 2,3 480 200-400 CJD6-A
(2P, 3P) JD6-A, HJD6-A,
NLGA, HLGA, 2,3 480 200-400
2,3 480 400-600 JXD6-A, HJXD6-A
NLGB, HLGB
NDGA, NDGB, 150,000 ED4 1 277 15-100
2,3 480 50-150 HFD6, HFXD6 2,3 480 70-250
HDGA, HDGB
7

NFGA, NFGB, 600 JD6-A, HJD6-A,


2,3 480 70-250 CLD6-A 2,3 480 200-400
HFGA, HFGB (2P, 3P) JXD6-A, HJXD6-A
800 HFD6, HFXD6 2,3 480 70-250 LD6-A, HLD6-A 2,3 480 200-600
MOLDED CASE
CIRCUIT BREAKERS

LMG LXD6-A, HLXD6-A 2,3 480 450-600


(2P, 3P) NJGA, HJGA 2,3 480 200-400
NLGA, NLGB, 1 277 15-100
2,3 480 400-600 BQD, CQD
HLGA, HLGB 2,3 277/480 20-30
MD6, MXD6, HMD6, ED4, HED4 1 277 15-100
2,3 480 500-800
HMXD6 125 ED4, ED6, HED4,
CED6 2,3 480 15-125
SCMD-A (2P, 3P) HED6
800 (3P) HFD6, HFXD6 2,3 480 70-250
SCMD6-B 1 277 15-125
SCND6-A NGB,HGB,LBG 2 277/480 15-125
1200 (3P) HFD6, HFXD6 2,3 480 70-250
SCND6-B 3 277/480 15-125
NDGA, NDGB, 1 277 15-100
2,3 480 50-150 BQD, CQD
HDGA, HDGB 2,3 277/480 20-30
NFGA, NFGB, 200,000
2,3 480 70-250 ED4, ED6 2,3 277 15-50
HFGA, HFGB ED4, HED4 1 480 15-100
HFD6, HFXD6 2,3 480 70-250
HED4, HED6 2,3 480 15-125
1200 NJGA, HJGA 2,3 480 200-400 250
LNG CFD6 FD6-A, FXD6-A,
(2P, 3P) NLGA, HLGA, (2P, 3P) 2,3 480 70-250
2,3 480 400-600 HFD6, HFXD6
NLGB, HLGB
MD6, MXD6, HMD6 1 277 15-125
2,3 480 400-800
HMXD6 NGB,HGB,LBG 2 277/480 15-125
ND6, NXD6, HND6 3 277/480 15-125
2,3 480 600-1200
HNXD6

7-222 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/06/18

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

240V Fuse Series Ratings 240V Fuse Series Ratings (continued)


Main Fuse Branch Breaker Series Main Fuse Branch Breaker
Series
Rating Max. Number Max. Rating Max. Number Max.
kAIR Type Amperes Type of Poles Amperes kAIR Type Amperes Type of Poles Amperes
J, R 15-600 (1,2,3P) QPH, BQH, BLH 1,2,3 15-125 125-200
R QJH2, QJ2H, QJ2 2,3 125-200
T 15-1200 (1,2,3P) QPH, BQH, BLH 1,2,3 15-125 (2,3P)
65,000 125-600
601-6000 QJH2, QJ2H 2,3 125-225
L QPH, BQH, BLH 1,2,3 15-125 (2,3P)
(1,2,3P) T, J
QP, BQ, BL 1,2,3 15-125 125-400
QJ2 2,3 125-225
HQP, HBQ, HBL, (2,3P)
3 15-100 70-600
QPH, BQH, BLH J, R HFD6, HFXD6 2,3 70-250
QPF, BQF, BLF, QHPF, (2,3P)
QE, BE, BLE, QEH, BLEH, 70-1200 HFD6, HFXD6 2,3 70-250
1 15-30 T 600-1200
15-200 (1,2,3P) BLHF, BQHF, QAF, BAF, NMG, HMG 2,3 600-800
T (2,3P)
QAFH, BAFH
(300V) HFD6, HFXD6 2,3 70-250
QEH, BLEH, QE, QPF,
QPHF, BLHF, BLE, BLF, 2 15-60 MD6, MXD6,
2,3 500-800
QAF, BAF, QAFH, BAFH 601-6000 HMD6, HMXD6
L
QT 1,2 15-50 (2,3P) NMG, HMG 2,3 600-800
QPH, BQH, BLH, HQP, ND6, NXD6,
15-600 (1,2,3P) 1,2 15-125 2,3 500-1200
HBQ, HBL HND6, HNXD6
ED4, HED4 1 15-100 15-600
J,R NGB,HGB,LBG 1,2,3 15-125
ED4, ED6, HED4, HED6 2,3 15-125 (1,2,3P)
QAF2, BAF2, QAFH2, 50-600
J,R NDGA, HDGA 2,3 50-150
15-600 (2,3P) BAFH2, QFGA2, BFGA2, 1 15-20 200,000 (2,3P)
QFGAH2, BFGAH2 70-600
J,R NFGA, HFGA 2,3 70-250
QPF2, BLF2, HQPF2, (2,3P)
1 15-30 200-600
HBLF2, QPHF2, BLHF2 J,R NJGA, HJGA 2,3 200-400
J, R (2,3P)
70-600 (2,3P) FD6-A, FXD6-A 2,3 70-250
100-600 (2,3P) QR2, QRH2, HQR2 2,3 100-250 400,600
J,R NLGA, HLGA 2,3 400-600
JD6-A, JXD6-A, JXD2-A, (1,2,3P)
2,3 200-400 15-1200
200-600 (2,3P) SJD6-A, SJD6-B T NGB,HGB,LBG 1,2,3 15-125
LD6-A 2,3 200-600 (1,2,3P)
300-600 (3P) SLD6-A, SLD6-B 3 300-600 50-1200
T NDGA, HDGA 2,3 50-150
450-600 (2,3P) LXD6-A 2,3 450-600 (2,3P)
100,000 ED4, HED4 1 15-100 70-1200
T NFGA, HFGA 2,3 70-250
ED4, ED6, HED4, HED6 2,3 15-125 (2,3P)
QAF2, BAF2, QAFH2, 200-1200
T NJGA, HJGA 2,3 200-400
BAFH2, HQAF2, HBAF2, (2,3)
15-1200 (2,3P) 1 15-20 400-1200
QFGA2, BFGA2, QF- T NLGA, HLGA 2,3 400-600
GAH2, BFGAH2 (2,3P)
QPF2, BLF2, HQPF2, NDGA, HDGA 2,3 50-150
1 15-30 601-6000 NFGA, HFGA 2,3 70-250
HBLF2, QPHF2, BLHF2 L
T (2,3P) NJGA, HJGA 2,3 200-400
70-1200 (2,3P) FXD6-A, FD6-A 2,3 70-250
100-600 (2,3P) QR2, QRH2, HQR2 2,3 100-250 NJGA, HLGA 2,3 400-600
450-1200 (2,3P) LXD6-A 2,3 450-600
JD6-A, JXD6-A,
2,3 200-400
JXD2-A
200-1200 (2,3P)
SJD6-A, SJD6-B 3 200-400
LD6-A 2,3 200-600
300-1200 (3P) SLD6-A, SLD6-B 3 300-600
ED4, HED4 1 15-100

7
ED4, ED6, HED4, HED6 2,3
FD6-A, FXD6-A 2,3 70-250
JD6-A, JXD6-A, JXD2-A 2,3 200-400
SJD6-A, SJD6-B 3 200-400

CIRCUIT BREAKERS
MOLDED CASE
601-6000 LD6-A 2,3 200-600
L
(2,3P) LXD6-A 2,3 450-600
SLD6-A, SLD6-B 3 300-600
SMD6, SMD6-B 3 500-800
SND6, SND6-B 3 500-1200
PD6, PXD6, SPD6 3 1200-1600
RD6, RXD6 3 1600-2000

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-223


Revised on 03/25/17

Molded Case Circuit Breakers


Series Connected Short Circuit Ratings General

480V Fuse Series Ratings


Series Main Fuse Branch Breaker
Rating Max. Number Max.
kAIR Type Amperes Type of Poles Amperes
60-400 (1,2,3P) ED4 1 60-100
50,000 J
15-400 (2,3P) ED4 2,3 15-100
J 15-400 (1,2,3P) ED4 1 15-50
T, J 70-600 (2,3P) FD6-A, FXD6-A 2,3 70-250
J, R 70-600 (2,3P) HFD6, HFXD6 2,3 70-250
JD6-A, JXD6-A
2,3 200-400
200-600 (2,3P) HJD6-A, HJX
T, J, R
LD6-A, HLD6 2,3 200-600
450-600 (2,3P) LXD6-A, HLD6 2,3 450-600
T 70-1200 (2,3P) HFD6, HFXD6 2,3 70-250
JD6-A, JXD6-A
2,3 200-400
HJD6-A, HJX
T, L 601-1200 (2,3P)
LD6-A, HLD6 2,3 200-600
LXD6-A, HLX 2,3 450-600
HFD6, HFXD6 2,3 70-250
MD6, MXD6
2,3 500-800
HMD6, HMXD6
ND6, NXD6
601-6000 2,3 500-1200
L HND6, HNXD6
(2,3P)
NDGA, HDGA 2,3 50-150
NFGA, HFGA 2,3 70-250
NJGA, HJGA 2,3 200-400
100,000 NLGA, HLGA 2,3 400-600
50-600
J,R NDGA, HDGA 2,3 50-150
(2,3P)
70-600
J,R NFGA, HFGA 2,3 70-250
(2,3P)
200-600
J,R NJGA, HJGA 2,3 200-400
(2,3P)
400-600
J,R NLGA, HLGA 2,3 400-600
(2,3P)
601-1200
T NDGA, HDGA 2,3 50-150
(2,3P)
601-1200
T NFGA, HFGA 2,3 70-250
(2,3P)
601-1200
T NJGA, HJGA 2,3 200-400
(2,3P)
601-1200
T NLGA, HLGA 2,3 400-600
(2,3P)
NDGA, HDGA 2,3 50-150
NFGA, HFGA 2,3 70-250
L 601-6000 (2,3P)
NJGA, HJGA 2,3 200-400
NLGA, HLGA 2,3 200-400
BQD, CQD 1 15-100
R 15-100 (1,2,3P)
BQD, CQD 2,3 20-30
200,000
BQD, CQD 1 15-100
T, J 15-200 (1,2,3P)
BQD, CQD 2,3 20-30
7 MOLDED CASE
CIRCUIT BREAKERS

7-224 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 05/31/18

Molded Case Circuit Breakers


IEC 947-2® AC Interrupting Ratings, 50/60 HZ KA Reference

220/240 Volts 380/415 Volts 500 Volts


Ampere Breaker Breaker
Rating Frame Type Icu Ics Icu Ics Icu Ics
15-125 ED ED6 65 17 35 9 — —
FXD6 65 33 35 18 — —
70-250 FD HFXD6 100 50 65 33 — —
HHFXD6 200 100 100 50 — —
JXD6(A) 65 33 40 20 — —
250-400 JD
HJXD6(A) 100 50 65 33 — —
400-600 LD LXD6(A) 65 33 40 20 — —
HLXD6(A) 100 50 65 33 — —
MXD6 65 33 40 20 — —
600-800 MD
HMXD6 100 50 65 33 — —
NXD6 65 33 40 20 — —
800-1200 ND
HNXD6 100 50 65 33 — —

7
CIRCUIT BREAKERS
MOLDED CASE

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-225


Molded Case Circuit Breakers
Typical Specifications Reference

General Specifications
Molded case circuit breakers shall provide circuit overcurrent protection with
inverse time and instantaneous tripping characteristics and shall be Siemens
Sentron, Sensitrip or approved equal.

All circuit breakers shall be listed by Underwriters’ Laboratories, Inc., conform


to applicable requirements of NEMA Standard Publication No. AB1 and meet
appropriate classifications of Federal Specifications W C 375B/Gen. Solid State Sensing Specifications
As indicated on the drawings, circuit breaker frames
400 Ampere through 3200-Ampere shall have
microprocessor-based RMS sensing trip units, with
All circuit breakers shall have a quick-make, quick-break over center toggle type the capability to measure through to the 21st harmonic.
mechanism and the handle mechanism shall be trip free to prevent holding contacts Automatic operation of all circuit breaker frames 400A
closed against a short circuit or sustained overload. All circuit breaker handles shall and larger shall be obtained by means of solid state
assume a position between “ON” and “OFF when tripped automatically. Multi-pole tripping elements providing inverse time delay and
circuit breakers shall be common-trip such that an overload or short circuit on any (instantaneous) and/or (short-time delay) circuit
one pole will result in all poles opening simultaneously. Arc extinction is to be protection. Continuous current ratings shall be adjustable
accomplished by magnetic arc chutes. All ratings are to be clearly visible. When from 20% to 100% of the trip unit rating, without the need
reverse feed is indicated on the drawings, in accordance with UL, circuit breakers for a rating plug. Long-time delay and instantaneous trip
with sealed trip units shall be supplied. shall be adjustable. The optional short-time trip function
shall have adjustable pick-up settings, three fixed times,
and I2t ramp. Circuit breaker frames 400A and larger, and
where indicated on the drawings, shall be 100% equip-
ment rated.
Thermal Magnetic Specifications
Unless otherwise noted on the drawings, all Circuit breakers 2000 Ampere
and below shall have thermal-magnetic trip units, with inverse time-current
Integral Ground
characteristics. Automatic operation of these circuit breakers shall be obtained by Fault Option
means of thermal-magnetic tripping devices located in each pole providing inverse Main and feeder circuit breakers, as indicated on the
time delay and instantaneous circuit protection. Circuit breakers shall be ambient drawings, shall be provided with integral ground fault
compensating in that, as the ambient temperature increases over 40°C, the circuit protection. Ground fault pick-up shall be adjustable from
breaker automatically derates itself so as to better protect its associated conductor. 20% to 70% of the circuit breakers maximum continuous
Thermal magnetic breakers from 250 to 2000A frames shall have thermal current rating. Ground fault time delay shall be adjustable
interchangeable trip units, with instantaneous magnetic trip settings that are with three 12t ramps.
adjustable and accessible from the front of all circuit breakers on frame sizes 250
Amperes and above. Where indicated, provide circuit breakers UL listed for
application at 100% of their continuous ampere rating in their intended enclosure. Metering Option
When indicated on the drawings, solid state trip breakers
shall be furnished with a plug-in or panel mounted
Motor Circuit Protectors metering device. This device shall simultaneously display
all three phase currents, as well as average current,
Where indicated on the drawings and in the combination motor starter/motor ground current, and phase unbalance. In addition it shall
control center schedule, furnish instantaneous magnetic trip only circuit breakers
7

display breaker status, a max log, and a trip log. The trip
for motor short circuit protection. The magnetic trips shall be adjustable and log will retain and display date, time and type of trip
accessible from the front of all circuit breakers frames. The continuous current (overload, short circuit or ground fault) for the most
MOLDED CASE
CIRCUIT BREAKERS

rating shall be between 1 and 800 Amperes as indicated on the drawing. recent 5 trip events.

Current Limiting Specifications


Where indicated on the drawings, Siemens current
limiting circuit breakers are to be furnished. Current
limiting circuit breakers shall limit the let-through I2t to a
value less than the I2t of one-half cycle wave of the
The interrupting rating of the circuit breakers shall be as indicated in the
symmetrical prospective current without any fusible
specifications, and shown on the drawing or single line diagram. The interrupting
elements when operating within its current range.
rating of the circuit breakers shall be at least equal to the available short circuit
current at the line terminals of the circuit breaker and correspond to the UL listed
integrated short circuit current rating specified.
Series Connected Combination Specifications
Where protective devices are applied in series combination,
such that the prospective available fault current exceeds
Internal Accessories the interrupting rating (AIR) of the downstream protective
Provide shunt trips, bell alarms, and auxiliary switches as shown on the contract devices, such combinations shall be UL recognized
drawings. Gold plated auxiliary switches shall be supplied for PLC connection. Internal combinations. All electrical equipment using these UL
accessories for all breakers shall be UL listed for field installation and modification. recognized circuit breaker combinations shall be clearly
marked in accordance with NEC Section 240-83(c).

Connection Accessories
Unless otherwise noted, Mechanical lugs shall be provided with all Molded Case
Breakers. Where indicated on the drawings, compression lugs shall be provided on
1200 Ampere frame and below circuit breakers. All compression lugs shall be
supplied by the Circuit Breaker Manufacturer. Where indicated on the drawings,
UL listed plug-in or rear connectors shall be supplied.

7-226 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Molded Case Circuit Breakers
Superseded Breakers General

Sentron Series Note Superseded Note Superseded


CED62B015-CED62B125 a
CLE62B015-CLE62B100 c
CE2B015-CE2B100
CED62S100A a
CLE62S100 c
CE2S100
CED63A001-CED63A125 a
CLE63A001-CLE63A125
CED63B015-CED63B125 a
CLE63B015-CLE63B100 c
CE3B015-CEB100
CED63S100A a
CLE63S100 c
CE3S100
HHED63B015-HHED63B125 a
HED63B015-HED63B125
CFD62A150, CFD62L150, CFD62A250 a
CLF62A150, CLF62A250
CFD62B070-CFD62B250 a
CLF62B070-CLF62B240 c
CJ2B125-CJ2B250
CFD62S250A a
CLF62S250
CFD63A150, CFD63L150, CFD63A250 a
CLF63A150, CLF63A250
CFD63B070-CFD63B250 a
CLF63B070-CLF63B250 c
CJ3B125-CJ3B250
CFD63S250A a
CLF63S250
CJD62B200-CJD62B400 a
CLJ62B100-CLJ62B400 d
CJ2B300-CJ2B400
CJD62H400, CJD62L400 a
CLJ62L400, CLJ62H400
CJD62S400A a
CLJ62S400 d
CJ2S400
CJD63B200-CJD63B400 a
CLJ63B200-CLJ63B400 d
CJ3B300-CJ3B400
CJD63H400, CJD63L400 a
CLJ63L400, CLJ63H400
CJD63S400A a
CLJ63S400 d
CJ3S400
CPD63B120-CPD63B160 e
CP3B120-CP3B160
ED21B015-ED21B100 a
E21B015-E21B100 b
EE1B015-EE1B100
ED22B015-ED22B100 a
E22B015-E22B100 b
EE2B015-EE2B100
ED22S100A a
E22S100A b
EE2S100
ED23B015-ED23B100 a
E23B015-E23B100 b
EE3B015-EE3B100
ED23S100A a
E23S100A b
EE3S100
ED41B015-ED41B100 a
E41B015-E41B100 b
EH1B015-EH1B100
ED42B015-ED42B125 a
E42B015-E42B100 b
EH2B015-ED2B125
ED42S100A a
E42S100 b
EH2S100
ED43B015-ED43B125 a
E43B015-E43B100 b
EH3B015-EH3B100
ED43S100A a
E43S100 b
EH3S100
ED61B015-ED61B100 a
E61B015-E61B100 b
EF1B015-EF1B020
ED62B015-ED62B125 a
E62B015-E62B100 b
EF2B015-EF2B100
ED62S100A a
E62S100A b
EF2S100
ED63A001-ED63A125 a
E63A001-E63A125 b
EF3A003, EF3J050, EF3L050-EF3A100, EF3H1
ED63B015-ED63B125 a
E63B015-E63B100 b
EF3B015-EF3B100
ED63S100A a
E63S100A b
EF3S100
HHED63B015-HHED63B125 a
HED63B015-HED63B125
FD62B070-FD62B250 f a
F62B070, F62B250
FD63B070-FD63B250 f a
F63B070-F63B250
FXD62A150, FXD62L150, FXD62A250 a
FJ62A150, FJ62L150-FJ62A250
FXD62B070-FXD62B250 f a
FJ62B070-FJ62B250 b
FJ2B070-FJ2B225
FXD62S250A a
FJ62S250 b
FJ2S225
FXD63A150, FXD63L150, FXD63A250 a
FJ63A150, FJ63L150-FJ63A250 b
FJ3A225

7
FXD63B070-FXD63B250 f a
FJ63B070-FJ63B250 b
FJ3B070-FJ3B225
FXD63S250A a
FJ63S250 b
FJ3S225

CIRCUIT BREAKERS
MOLDED CASE
HED41B015-HED41B100 a
HE41B015-HE41B100
HED42B015-HED42B125 a
HE42B015-HE42B100
HED43B015-HED43B125 a
HE43B015-HE43B100
HED61B015-HED61B100 a
HE61B015-HE61B100
b
HE2B015-HE2B100
HED63B015-HED63B125 a
HE63B015-HE63B100 b
HE3B015-HE3B100
HFD62B070-HFD62B250 a
HF62B070-HF62B250
HFD63B070-HFD63B250 a
HF63B070-HF63B250
HHED63B015-HHED63B125 a
HED63B015-HED63B125
HJD63B200-HJD63B400 a
HJ63B200-HJ63B400 b
HJ3B125-HJ3B400
HLD63B250-HLD63B600 a
HL63B450-HL63B600 b
HL3B450-HL3B600
HMD63B500-HMD63B800 b
HN3B500-HN3B800
HND63B100-HND63B120 b
HK3B100-HK3B120
HPD63B120-HPD63B160 b
HP3B120-HP3B160
HRD63B160-HRD63B200 b
HR3B160-HR3B200

a Mechanically and electrically interchangeable. d Electricallyinterchangeable only if the system interrupting f Effective1994 — The FD6 and FXD6 types have been
b Electrically interchangeable only, refer to sales office for capacity is less than or equal to: replaced by FD6-A and FXD6-A type thermal / magnetic
further details. 200 kA at 240V AC circuit breakers — mechanically and electrically
c Electrically interchangeable only if the system interrupting 150 kA at 480V AC interchangeable with the exception that FXD6-A and FD6-A
capacity is less than or equal to: 100 kA at 600V AC have 22kA at 600V AC ratings versus 18kA at 600V AC for
200 kA at 240V AC e Refer to local sales office for replacement information. types FXD6 and FD6.
200 kA at 480V AC
100 kA at 600V AC

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-227


Revised on 02/06/18

Molded Case Circuit Breakers


Superseded Breakers General

Sentron Series Note Superseded Note Superseded


JD62B200-JD62B400 a JLB200-JL62B400 b JL2B070-JL2B400
JD63B200-JD63B400 a JL63B200-JL63B400 b JL3B0L0-JL3B400
JXD22B200-JXD22B400 a JD22B200-JD22B400 b JD2B250-JD2B400
JXD22S400A a JD22S400 b JD2S400
JXD23B200-JXD23B400 a JD23B200-JD23B400 b JD3B250-JD3B400
JXD23S400A a JD23S400 b JD3S400
JXD62B200-JXD62B400 a JJ62B200-JJ62B400 b JJ2B250-JJ2B400
JXD62H400, JXD62L400 a JL62L400, JL62H400 b JL2L400-JL2H400
JXD62S400A a JJ62S400A
JXD63B200-JXD63B400 a JJ63B200-JJ63B400 b JJ3B200-JJ3B400
JXD63H400, JXD63L400 a JL63A400, JL63H400, JL63L400 b JL3H400, JL3L400, JL3A225
JXD63S400A a JJ63S400A
LD62B250-LD62B500 a LL63B250-LL62B600 b LL2B450-LL2B600
LD62B250-LD63B600 a LL63B250-LL63B600 b LL3B450-LL3B600
LXD62B450-LXD62B600 a LJ62B450-LJ62B600
LXD62J600, LXD62L600 b LL2H600, LL2U600, LL2X600
LXD62S600A a LJ62S600
LXD63B450-LXD63B600 a LJ63B450-LJ63B600
LXD64H600, LXD63L600 a LL63H600, LL63L600 b LL3A450, LL3H600
LXD63S600A a LJ63S600A b LL3S600
MD62B500-MD62B800 b KM2B500-KM2B800
MD63B500-MD63B800 b KM3B500-KM3B800
MXD62A800, MXD62H800, MXD62L800 b KM2A800, KM2H800, KM2L800
MXD62S800A b KM2S800
MXD63A800, MXD63H800, MXD63L800 b KM3A600, KM3H800, KM3L800
MXD63S800A b KM3S800
ND63B100-ND63B900 b KP3B100-KP3B900
NXD63S120A b KP3S120
PD63B120-PD63B160 b HP3B120-HP3B160
PXD63S160A b HP3S160
RD63B160-RD63B200 b HR3B160-HR3B200
QR22B100 – QR22B225 QJ22B060-QJ22B225
QR22B100H – QR22B225H QJ22B060H-QJ22B225H
HQR23S250HA QJ22S225
QJ23B100 – QR23B225 QJ23B060-QJ23B225
7

QR23B100H – QR23B225H QJ23B060H-QJ23B225H


QRH22B100 – QRH22B225 QJH22B060-QJH22B225
MOLDED CASE
CIRCUIT BREAKERS

QRH23B100 – QRH23B225 QJH23B060-QJH23B225


HQR23S250HA QJH23S225 a
QJH22B060-QJH22B225 a QJ2H125-QJ2B225
QJH23B060-QJH23B225 a QJ3H125-QJ3H225
QJH23S225 a QJ3S225
RD63B160-RD63B200 b HR3B160-HR3B200
RXD63S200A b HR3S200
SCJD6B200LI-SCJD6B400LI a SCJD69200-SCJD69400
SCJD6B200LIG-SCJD6B400LIG a SCJD69200G-SCJD69400G
SCJD6B200LSIG-SCJD6B400LSIG a SCJD69200NGT-SCJD69400NGT
SCJD6B200LSI-SCJD6B400LSI a SCJD69200NT-SCJD69400NT
SCLD6B300LI-SCLD6B600LI a SCLD69300-SCLD69600
SCLD6B300LIG-SCLD6B600LIG a SCLD69300G-SCLD69600G
SCLD6B300LSIG-SCLD6B600LSIG a SCLD69300NGT-SCLD69600NGT
SCLD6B300LSI-SCLD6B600LSI a SCLD69300NT-SCLD69600NT
SCMD6B600LI-SCMD6B800LI a SCMD69600A-SCMD69800A
SCMD6B600LIG-SCMD6B800LIG a SCMD69600AG-SCMD69800AG
SCMD6B600LSIG-SCMD6B800LSIG a SCMD69600ANGT-SCMD69800ANGT
SCMD6B600LSI-SCMD6B800LSI a SCMD69600ANT-SCMD69800ANT

a Mechanically and electrically interchangeable. c Electrically


interchangeable only if the system  Electrically
d interchangeable only if the system
b Electrically
interchangeable only, refer to sales office for interrupting capacity is less than or equal to: interrupting capacity is less than or equal to:
further details. 200 kA at 240V AC 200 kA at 240V AC
200 kA at 480V AC 150 kA at 480V AC
100 kA at 600V AC 100 kA at 600V AC
e Refer to local sales office for replacement information.

7-228 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog


Revised on 02/06/18

Molded Case Circuit Breakers


Superseded Breakers General

Sentron Series Note Superseded Note Superseded


SCND6B800LI-SCND6B120LI a SCND69800A-SCND69120A
SCND6B800LIG-SCND6B120LIG a SCND69800AG-SCND69120AG
SCND6B800LSIG-SCND6B120LSIG a SCND69800ANGT-SCND69120ANGT
SCND6B800LSI-SCND6B120LSI a SCND69800ANT-SCND69120ANT
SHJD6B200LI-SHJD6B400LI a SHJD69200-SHJD69400 a SHJ63B200-SHJ63B400G
SHJD6B200LIG-SHJD6B400LIG a SHJD69200G-SHJD69400G a SHJ63B200G-SHJ63B400G
SHJD6B200LSIG-SHJD6B400LSIG a SHJD69200NGT-SHJD69400NGT a SHJ63N200G-SHJ63N400G
SHJD6B200LSI-SHJD6B400LSI a SHJD69200NT-SHJD69400NT a SHJ63N200-SHJ63N400
SHLD6B300LI-SHLD6B600LI a SHLD69300-SHLD69600 a SHL63B300-SHL63B600
SHLD6B300LIG-SHLD6B600LIG a SHLD69300G-SHLD69600G a SHL63B300G-SHL63B600G
SHLD6B300LSIG-SHLD6B600LSIG a SHLD69300NGT-SHLD69600NG a SHL63N300G-SHL63N600G
SHLD6B300LSI-SHLD6B600LSI a SHLD69300NT-SHLD69600NT a SHL63N300-SHL63N600
SHND6B100LI-SHND6B120LI a SHND69100A-SHND69120A a SHND69100-SHND69800
SHND6B100LIG-SHND6B120LIG a SHND69100AG-SHND69120AG a SHND69100G-SHND69800G
SHPD6B140LI-SHPD6B160LI a SHPD69140-SHPD69160 b SHPF3B120-SHPF3B160
SHPD6B140LIG-SHPD6B160LIG a SHPD69140G-SHPD69160G b SHPF3B120G-SHPF3B160G
SHND6B100LSIG-SHND6B120LSIG a SHND69100NGT-SHND69800NGT a SHKF3N100G-SHKF3N800G
SHND6B100LSI-SHND6B120LSI a SHND69100NT-SHND69800NT b SHKF3N100-SHKF3N800
SJD6B200LI-SJD6B400LI a SJD69200-SJ369400 a SJL63B200-SJL63B400
SJD6B200LIG-SJD6B400LIG a SJD69200G-SJD69400G a SJL63B200G-SJL63B400G
SJD6B200LSIG-SJD6B400LSIG a SJD69200NGT-SJD69400NGT a SJL63N200G-SJL63N400G
SJD6B200LSI-SJD6B400LSI a SJD69200NT-SJD69400NT a SJL63N200-SJL63N400
SLD6B300LI-SLD6B600LI a SLD69300-SLD69600 a SLL63B300-SLL63B600
SLD6B300LIG-SLD6B600LIG a SLD69300G-SLD69600G a SLL63B300G-SLL63B600G
SLD6B300LSIG-SLD6B600LSIG a SLD69300NGT-SLD69600NGT a SLL63N300G-SLL63N600G
SLD6B300LSI-SLD6B600LSI a SLD69300NT-SLD69600NT a SLL63N300-SLL63N600
SMD6B600LI-SMD6B800LI a SMD69600A-SMD69800A a SMD69600-SMD69800
SMD6B600LIG-SMD6B800LIG a SMD69600AG-SMD69800AG a SMD69600G-SMD69800G
SMD6B600LSIG-SMD6B800LSIG a SMD69600ANGT-SMD69800ANGT a SMD69600NGT-SMD69800NGT
SMD6B600LSI-SMD6B800LSI a SMD69600ANT-SMD69800ANT a SMD69600NT-SMD69800NT
SND6B800LI-SND6B120LI a SND69800A-SND69120A a SND69100-SND69800
SND6B800LIG-SND6B120LIG a SND69800AG-SND69120AG a SND69100G-SND69800G
SND6B800LSIG-SND6B120LSIG a SND69800ANGT-SND69120ANGT a SND69100NGT-SND69800NGT
SND6B800LSI-SND6B120LSI a SND69800ANT-SND69120ANT a SND69100NT-SND69800NT
SHPD6B140LI-SHPD6B160LI a SPD69140-SPD69160 b SHPF3B120-SHPF3B160

7
SHPD6B140LIG-SHPD6B160LIG a SPD69140G-SPD69160G b SHPF3B120G-SHPF3B160G
SHPD6B140LSIG-SHPD6B160LSIG a SPD69140NGT-SPD69160NGT b SHPF3N120-SHPF3N160G

CIRCUIT BREAKERS
MOLDED CASE
SHPD6B140LSI-SHPD6B160LSI a SPD69140NT-SPD69160NT b SHPF3N120G-SHPF3N160G
— — d BQCC1B015-BQC1B030
— — d CC1B015-CC1B030
— — d CC2B015-CC2B030
— — d CC3B015-CC3B030
— — d EF2A003, EF2H050, EF2L050, EF2A100
— — d EF2H150, EF2L150
— — d EH1B015-EH1B100
— — d EH2B015-EH2B100
— — d EH3B015-EH3B100
— — c HE2A003, HE2H050, HE2L050-HE2A100
— — c HE3A003, HE3H050, HE3L050-HE3A100
— — c HE3B015-HE3B100

a Mechanically and electrically interchangeable. dTheseunits are no longer manufactured, and no


b Electricallyinterchangeable only, refer to sales replacement is available.
office for further details.
cThese units are for replacement purposes only.
Consult sales office for availability.

Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog 7-229


Molded Case Circuit Breakers
Notes
7 MOLDED CASE
CIRCUIT BREAKERS

7-230 Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog