0% found this document useful (0 votes)
11 views9 pages

R4V R6V Uk

The document provides details on the Pilot Operated Pressure Relief Valves series R4V and R6V, including their characteristics, features, and technical specifications. These valves are designed for manual adjustment and include options for vent functions, with various pressure stages and adjustment modes. Technical data such as nominal sizes, operating pressures, and electrical specifications are also included for both series.

Uploaded by

shubham.uphy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views9 pages

R4V R6V Uk

The document provides details on the Pilot Operated Pressure Relief Valves series R4V and R6V, including their characteristics, features, and technical specifications. These valves are designed for manual adjustment and include options for vent functions, with various pressure stages and adjustment modes. Technical data such as nominal sizes, operating pressures, and electrical specifications are also included for both series.

Uploaded by

shubham.uphy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves

Characteristics Series R4V / R6V

Pilot operated pressure relief valves series R4V (DIN


24340 Form D) and R6V (DIN 24340 Form E) consist of
a manually adjusted pilot stage and a seated type main
stage.
A vent function with a solenoid operated directional valve
is available for circulation at minimum pressure.

Features
• Pilot operated with manual adjustment
• 2 interfaces R6V06 R6V06 with vent valve
- R4V subplate ISO 6264 (DIN 24340 Form D)
with VV01 vent valve
- R6V subplate ISO 6264 (DIN 24340 Form E)
4 with CETOP 03 vent valve
• 3 pressure stages
• 3 adjustment modes:
- hand knob
- acorn nut with lead seal
- cylinder lock
• Remote control via port X
R4V06 with vent valve

Function: R6V06 with vent valve


Series R4V/R6V
System pressure in port P is applied via the X gallery to
the spring loaded cone in the pilot head. The pilot head
controls the pressure in the Z area on top of the main car-
tridge which is additionally kept close by the main spring.
If the pilot pressure exceeds the setting pressure the pilot
cone opens and thus limits the pilot pressure.
When the system pressure exceeds the pilot pressure
plus the spring force, the main cartridge opens to port
T and limits the pressure in port P to the adjusted level.

Series R4V/R6V with vent function


Additionally to the relief function, a solenoid operated
vent valve connects the Z area to tank. This allows oil
circulation from P to T at minimum pressure drop. The vent
valve can either be a standard CETOP 03 valve (R6V) or
a sandwich unit (R4V). For both types the vent position
can be either at the energized or de‑energized solenoid.

Code 09 Code 11
A B A B

T P T T P T
X X

PZ PZ
Y Y

R4V-R6V UK.indd 26.03.24

4-14 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves
Ordering Code Series R4V / R6V

R V 5
Pressure Relief Max. Pressure Pilot oil Seals Modifications
valve function pressure setting range
(350 bar)
Interface Nominal Drain port Adjustment Design Design
size series
(not required
for ordering)

Code Interface Code Seals


1 NBR
5 FPM
4
Subplate
mounting

6
ISO 6264 Code
A
Design
R4V
4
B R6V

Code Nominal size Pilot oil


03 NG10 Code Drain line
06 NG25 0 internal
10 NG32 external from sub-
1 1)
plate
external from valve
2 2)
body (Y-port)
Code Interface Drain port
Y port in
3 R4V
mounting pattern
Code Adjustment
9 R6V Y-port = G 1/8“
Hand knob 32 mm
1
dia. (standard)
Acorn nut
3
Code Pressure stages with lead seal
1 up to 105 bar 4 Cylinder lock
3 up to 210 bar
5 up to 350 bar

1) R4V only.
2) R6V only.

R4V-R6V UK.indd 26.03.24

4-15 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves
Ordering Code Series R4V / R6V

R V 5
Pressure Relief Max.pressure Pressure Pilot oil Solenoid Seals Modifications
valve function (350 bar) setting range voltage

Interface Nominal Drain port Adjustment Vent Design Design


size valve series
function (not required
for ordering)

Code Interface Code Modification


Vent function with
0311)4)
slow unloading
4
Vent function with
Subplate VFM 2)4)
slow unloading
mounting
4 6
ISO 6264

Code Seals
1 NBR
5 FPM

Code Nominal size


03 NG10
Code Design
06 NG25
A R4V
10 NG32
B R6V

Code Interface Drain port Code Voltage


Y port in G0R 12 V =
3 R4V
mounting pattern
G0Q 24 V =
9 R6V Y-port = G 1/8“
GAR3) 98 V =
GAG3) 205 V =
110 V / 50 Hz
Code Pressure stages W30
120 V / 60 Hz
1 up to 105 bar 230 V / 50 Hz
W31
3 up to 210 bar 240 V / 60 Hz
5 up to 350 bar

Code Vent valve


Code Adjustment Solenoid not activ.
09
Hand knob unpress. circulation
1
(Standard) Solenoid activated
11
Acorn nut unpress. circulation
3
with lead seal
Turning knob
4
with key lock
Pilot oil
Code Drain line
0 internal
external
1 1)
from subplate
external from valve
2 2)
body (Y-port)

1) R4V only.
2) R6V only.
3)
To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.
4) Vent valve function code 09 only.

R4V-R6V UK.indd 26.03.24

4-16 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves
Technical Data Series R4V / R6V

R4V/R6V
General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 6264 (DIN 24340)
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight Series R4V [kg] 2.7 4.5 6.0
Series R6V [kg] 4.5 5.8 7.8
Hydraulic
Max. operating pressure [bar] Ports P (or A) and X up to 350, Port T (or B) and Y 30
Pressure stages [bar] 105, 210, 350
Nominal flow Series R4V [l/min] 90 300 600

Fluid
Series R6V [l/min] 250
Hydraulic oil according to DIN 51524
500 650
4
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406; 18/16/13

R4V/R6V with vent function


General
Nominal size NG10 NG25 NG32
Interface Subplate mounting acc. ISO 6264 (DIN 24340)
Mounting position Unrestricted, horizontal mounting preferred
Ambient temperature [°C] -20...+60
MTTFD value [years] 75
Weight Series R4V [kg] 4.4 6.2 7.7
Series R6V [kg] 5.9 7.2 9.2
Hydraulic
Max. operating pressure [bar] Ports P (or A) and X up to 350, port T (or B) and Y 30
Pressure stages [bar] 105, 210, 350
Nominal flow Series R4V [l/min] 90 300 600
Series R6V [l/min] 250 500 650
Fluid Hydraulic oil according to DIN 51524
Viscosity, permitted [cSt] / [mm²/s] 20 ... 400
recommended [cSt] / [mm²/s] 30 ... 80
Fluid temperature [°C] -20...+70 (NBR: -25...+70)
Filtration ISO 4406; 18/16/13
Electrical
Duty ratio [%] 100 ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code G0R G0Q GAR GAG W30 W31
110 V/50 Hz 230 V/50 Hz
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
120 V/60 Hz 240 V/60 Hz
Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5
Current consumption hold [A] 2.72 1.29 0.33 0.13 0.6 / 0.55 0.3 / 0.27
in rush [A] 2.72 1.29 0.33 0.13 2.5 / 2.4 1.25 / 1.2
Power consumption hold [W] 32.7 31 31.9 28.2 70 / 70 VA 70 / 70 VA
in rush [W] 32.7 31 31.9 28.2 280 / 290 VA 280 / 290 VA
Solenoid connection Connector as per EN175301-803, solenoid identification as per ISO 9461
Wiring min. [mm2] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended

R4V-R6V UK.indd 26.03.24

4-17 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves
Characteristic Curves Series R4V / R6V

p/Q performance curves 1)


NG10 NG25

4
NG32

Minimum pressure curve

All characteristic curves measured with HLP46 at 50 °C.

1) The performance curves are measured with external drain.


For internal drain the tank pressure has to be added to curve.

R4V-R6V UK.indd 26.03.24

4-18 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves
Dimensions Series R4V / R6V

R6V

Y: external drain port G 1/8“

NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0 – 22.1 – 22.1 53.8 – 26.9 – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70 – 35 – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.

NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-09-*-97 80 26.9 114 27 88 20.5 25 52 117 141 180 29.5
25 6264-08-13-*-97 100 35 117.5 46.5 91.5 – 25 12 37.9 124.5 141 – 180 36.5
32 6264-10-17-*-97 120 41.3 124.5 51.3 98.5 26.5 13.5 44.3 153 141 180 46.5

NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)


10 6264-06-09-*-97 14.7 4.8 7.5 10 M12 20 13.5 20 SPP 3R6B 910
25 6264-08-13-*-97 23.4 6.3 7.5 10 M16 27 17.5 25 SPP 6R10B 910
32 6264-10-17-*-97 32 6.3 7.5 10 M18 28 20 30 SPP 10R12B 910

NG Surface finish
NBR FPM
10 BK494 4x M12x45 ISO 4762-12.9 108 Nm ±15 % S26-98589-0 S26-98589-5
25 BK366 4x M16x70 ISO 4762-12.9 264 Nm ±15 % S26-96396-0 S26-96396-5
32 BK507 4x M18x75 ISO 4762-12.9 398 Nm ±15 % S26-96392-0 S26-96392-5

1) Details see chapter 12, series SPP.

R4V-R6V UK.indd 26.03.24

4-19 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves
Dimensions Series R4V / R6V

R6V with vent function

Y: external drain port G 1/8“

NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-09-*-97 53.8 47.5 0 – 22.1 – 22.1 53.8 – 26.9 – – –
25 6264-08-13-*-97 66.7 55.6 23.8 – 11.1 – 33.4 70 – 35 – – –
32 6264-10-17-*-97 88.9 76.2 31.8 – 12.7 – 44.5 82.6 – 41.3 – – –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.

NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-09-*-97 80 26.9 203.4 27 88 136.3 25 12 52 117 163.8 180 36.5
25 6264-08-13-*-97 100 35 206.9 46.5 91.5 139.8 25 12 37.9 124.5 163.8 – 180 36.5
32 6264-10-17-*-97 120 41.3 213.9 51.3 98.5 146.8 25 12 44.3 153 163.8 180 36.5

NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)


10 6264-06-09-*-97 14.7 4.8 7.5 10 M12 20 13.5 20 SPP 3R6B 910
25 6264-08-13-*-97 23.4 6.3 7.5 10 M16 27 17.5 25 SPP 6R10B 910
32 6264-10-17-*-97 32 6.3 7.5 10 M18 28 20 30 SPP 10R12B 910

NG Surface finish
NBR FPM
10 BK494 4x M12x45 ISO 4762-12.9 108 Nm ±15 % S26-98589-0 S26-98589-5
25 BK366 4x M16x70 ISO 4762-12.9 264 Nm ±15 % S26-96396-0 S26-96396-5
32 BK507 4x M18x75 ISO 4762-12.9 398 Nm ±15 % S26-96392-0 S26-96392-5

1) Details see chapter 12, series SPP.

R4V-R6V UK.indd 26.03.24

4-20 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves
Dimensions Series R4V / R6V

R4V

NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0 66.7 58.8 33.4 7.9 14.3 –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0 79.4 73 39.7 6.4 15.9 –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0 96.8 92.8 48.4 3.8 21.4 –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.

NG ISO-code B1 B2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
10 6264-06-07-*-97 87.3 33.35 83 21 – – 62.5 – 25 90.8 – 143 181 144.8
25 6264-08-11-*-97 105 39.7 107.5 29 – – 87 – 30.9 123 – 143 181 144.8
32 6264-10-15-*-97 120 48.4 120 30 – – 99.5 – 29.8 143.5 – 143 181 144.8

NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)


10 6264-06-07-*-97 15 7 7.1 8 M10 16 10.8 17 SPP 3M6B 910
25 6264-08-11-*-97 23.4 7.1 7.1 8 M10 18 10.8 17 SPP 6M8B 910
32 6264-10-15-*-97 32 7.1 7.1 8 M10 20 10.8 17 SPP 10M12B 910

NG Surface finish
NBR FPM
10 BK505 4x M10x35 ISO 4762-12.9 63 Nm ±15 % S26-58507-0 S26-58507-5
25 BK485 4x M10x45 ISO 4762-12.9 63 Nm ±15 % S26-58475-0 S26-58475-5
32 BK506 6x M10x45 ISO 4762-12.9 63 Nm ±15 % S26-58508-0 S26-58508-5

1) Details see chapter 12, series SPP.

R4V-R6V UK.indd 26.03.24

4-21 Parker Hannifin Corporation


Catalogue MSG11-3500/UK Pilot Operated Pressure Relief Valves
Dimensions Series R4V / R6V

R4V with vent function

NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y6
10 6264-06-07-*-97 42.9 35.8 21.5 – 7.2 21.5 0 66.7 58.8 33.4 7.9 14.3 –
25 6264-08-11-*-97 60.3 49.2 39.7 – 11.1 20.6 0 79.4 73 39.7 6.4 15.9 –
32 6264-10-15-*-97 84.2 67.5 59.5 42.1 16.7 24.6 0 96.8 92.8 48.4 3.8 21.4 –
Tolerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2.

NG ISO-code B1 B2 B3 H1 H2 H3 H4 H6 L1 L2 L3 L4 L5 L6 L7
10 6264-06-07-*-97 87.3 33.35 70 130 21 68.5 109.5 – 25 90.8 – 143 181 165.6 144.8
25 6264-08-11-*-97 105 39.7 70 154.5 29 93 134 – 30.9 123 – 143 181 165.6 144.8
32 6264-10-15-*-97 120 48.4 70 167 30 105.5 146.5 – 29.8 143.5 – 143 181 165.6 144.8

NG ISO-code d1max d2max d3 t3 d4 t4 d5 d6 Subplate 1)


10 6264-06-07-*-97 15 7 7.1 8 M10 16 10.8 17 SPP 3M6B 910
25 6264-08-11-*-97 23.4 7.1 7.1 8 M10 18 10.8 17 SPP 6M8B 910
32 6264-10-15-*-97 32 7.1 7.1 8 M10 20 10.8 17 SPP 10M12B 910

NG Surface finish
NBR FPM
10 BK505 4x M10x35 ISO 4762-12.9 63 Nm ±15 % S26-58507-0 2) S26-58507-5 2)
25 BK485 4x M10x45 ISO 4762-12.9 63 Nm ±15 % S26-58475-0 2) S26-58475-5 2)
32 BK506 6x M10x45 ISO 4762-12.9 63 Nm ±15 % S26-58508-0 2) S26-58508-5 2)
VV01, AC solenoid S26-35237-0 S26-35237-5
VV01, DC solenoid S56-40609-0 S56-40609-5
1) Details see chapter 12, series SPP.
2) Please combine seal kit of one size with seal kit of VV01 solenoid for complete seal kit.

R4V-R6V UK.indd 26.03.24

4-22 Parker Hannifin Corporation

You might also like