iES8G www.iS5com.
com
Intelligent 8 Port Managed Gigabit Ethernet Switch
Features
ââ Rapid Ring Recovery: iRing (recovery time
<20ms up to 250 ethernet switches)
ââ iBridge is a unique feature that supports third party
ring technologies
ââ STP/RSTP/MSTP supported
ââ Supports PTP Client (Precision Time Protocol)
clock synchronization
ââ IGMP v2/v3 (IGMP snooping support)
for filtering multicast traffic
ââ Port Trunking for easy of bandwidth management
ââ SNMP v1/v2c/v3 support for secure network management
ââ RMON for traffic monitoring
ââ Supports DDM (Digital Diagnostic Monitoring) function
for SFP modules
ââ Supports LLDP (Link Layer Discovery Protocol)
ââ Event notifications via Syslog, Email, SNMP trap,
and Relay Output
ââ Port lock to prevent access from unauthorized MAC address
ââ iManage Software Suite (iMSS) supports centralized
management and configurable by Web-based, Telnet,
Console(CLI), Windows NT/2000/XP/2003/VISTA/7
ââ IP-40 Galvanized Steel housing
ââ DIN-Rail and wall mounting
ââ 4x10/100/1000 Base T(X) Ports or 4x100/1000 Base (X)
SFP Ports
Tel: +905-670-0004
iS5com.com
Fax: +289-401-5206
Email: info@is5com.com
#3-7490 Pacific Circle, Mississauga, Ontario, L5T 2A3
All specifications are subject to change without notice. IS5 REV.12092015 Page—1
Introduction
The iES8G is a managed Ethernet switch with Ethernet Redundancy protocols such as iRing (recovery time <20ms
up to 250 ethernet switches), iBridge and MSTP/RSTP/STP (IEEE 802.1s/w/D). The iES8G can protect your
mission-critical applications from network interruptions or temporary malfunctions to restore connectivity with its
fast recovery technology. The iBridge technology provides a means to complement and interconnect with most third
party proprietary ring technologies. The iES8G can be managed centrally and conveniently by our powerful windows
utility called the iManage Software Suite. The product is made from galvanized steel and has a wide operating
temperature range from -40°C to +85°C suitable for the harshest of environments without the use of fans.
iManage Software Suite
The iManage Software Suite provides users a way to conveniently manage and monitor all of the industrial Ethernet
switches on the network.
Network connection DDM connection Topology View
Monitoring and Configuration interface
All specifications are subject to change without notice | IS5 REV.12092015 www.iS5com.com | Page—2
Specifications
Model Number iES8G
Physical Ports
10/100/1000 Base-T(X) Ports in RJ45
4
Auto MDI/MDIX
Gigabit Combo Port with 10/100/1000Base-T(X)
4- Base-T(X) or 4- Base (X) SFP
or 100/1000Base-X SFP Port
Technology
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3z for 1000Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow control
IEEE 802.3ad for LACP (Link Aggregation Control Protocol )
Ethernet Standards IEEE 802.1D for STP (Spanning Tree Protocol)
IEEE 802.1p for COS (Class of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
MAC Table 8192 MAC addresses
Priority Queues 4
Processing Store-and-Forward
Switching latency: 7 us
Switching bandwidth: 16Gbps
Switch Properties Max. Number of Available VLANs: 4096
IGMP multicast groups: 1024
Port rate limiting: User Define
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1Q ) to segregate and secure network traffic
Security Features
Supports Q-in-Q VLAN for performance & security to expand the VLAN space
Radius centralized password management
SNMP V1/V2c/V3 encrypted authentication and access security
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (iRing) with recovery time less than 20ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
Software Features
Port configuration, status, statistics, monitoring, security
SNTP for synchronizing of clocks over network
Support PTP Client (Precision Time Protocol) clock synchronization
DHCP Server / Client support
Port Trunk support
MVR (Multicast VLAN Registration) support
Network Redundancy iRing, MSTP
Relay output for fault event alarming
Syslog server / client to record and view events
Warning / Monitoring System
Include SMTP for event warning notification via email
Event selection support
RS-232 Serial Console Port RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1
All specifications are subject to change without notice | IS5 REV.12092015 www.iS5com.com | Page—3
LED Indicators
Power Indicator Green : Power LED x 3
R.M. Indicator Green : Indicate system operated in iRing Master mode
Ring Indicator Green : Indicate system operated in iRing mode
Fault Indicator Amber : Indicate unexpected event occurred
10/100/1000Base-T(X) RJ45 port indicator Green for port Link/Act. Amber for 100Mbps indicator
100/1000Base-X SFP Port Indicator Green for port Link/Act.
Fault contact
Relay Relay output to carry capacity of 1A at 24VDC
Power
Dual DC inputs 10 to 48VDC, Dual DC Inputs 36-72VDC, or Single input universal supply
Redundant Input Power
88-370VDC or 85-264VAC with a single 10-48VDC Backup.
Power Consumption (Typ.) 10 Watt
Overload Current Protection Present
Reverse Polarity Protection Internal
Physical Characteristics
Enclosure IP-40 Galvanized Steel
Dimension (W x D x H) 101.6 (W) x 110.3 (D) x 153.8 (H) mm (4 x 4.34 x 6.05 inches)
Weight (g) ~2500 g
Environmental
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Operating Temperature -40°C to 85°C (-40°F to 185°F)
Operating Humidity 5% to 95% Non-condensing
Regulatory approvals
EMI FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),
EMS
EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
Shock IEC60068-2-27
Free Fall IEC60068-2-32
Vibration IEC60068-2-6
Safety EN60950-1
Warranty
Warranty 5 Years
All specifications are subject to change without notice | IS5 REV.12092015 www.iS5com.com | Page—4
Dimensions
2.56 [65.13]
6.32 [160.49]
5.93 [150.63]
All Dimensions are in Inches
6.32 [160.49]
5.93 [150.63] 2.56 [65.13]
6.64 [168.66]
6.82 [173.12]
6.64 [168.66]
7.53 [191.26]
Ordering Information
Power Ethernet Port Ethernet Ethernet Ethernet Ethernet
Base Mount Description
Supply 1-4(6) Port 5 Port 6 Port 7 Port 8
iES8G HV D 6RJ45 XX XX 1GSFP 1GSFP
iES8G | | | | | | | Core assembly and packaging
LV | | | | | | Dual Input (10-48VDC)
MV | | | | | | Dual Input (36-72VDC)
Single Input 88-370VDC or 85-264VAC with Single
HV | | | | | |
10-48VDC Backup
D | | | | | DIN Rail Mounting
P | | | | | Panel Mounting
N | | | | | No Mounting Hardware
4GRJ45 | | | | 4 X 10/100/1000Base TX RJ45
| XX XX XX XX None
| 1GRJ45 1GRJ45 1GRJ45 1GRJ45 10/100/1000Base TX RJ45
| 1GSFP 1GSFP 1GSFP 1GSFP 100/1000 (X) SFP (Blank no optical transceiver**)
Combo Port 1 x 10/100/1000Base TX RJ45 and 1 x
| 1CGX 1CGX 1CGX 1CGX
100/1000 (X) No Transceivers**
6RJ45 | | | | 6 X 10/100Base TX RJ45
XX XX None
1GMMSC 1GMMSC 1000 SX Multimode SC, 850nm, 550m
1GMMST 1GMMST 1000 SX Multimode ST, 850nm, 550m
1GSST10 1GSST10 1000 LX Singlemode ST, 1310nm, 10km
1GSSC10 1GSSC10 1000 LX Singlemode SC, 1310nm, 10km
1GSST40 1GSST40 1000 LX Singlemode ST, 1310nm, 40km
1GSSC40 1GSSC40 1000 LX Singlemode SC, 1310nm, 40km
1GSST70 1GSST70 1000 LX Singlemode ST, 1550nm, 70km
1GSSC70 1GSSC70 1000 LX Singlemode SC, 1550nm, 70km
Example Order Code: iES8G-MV-D-4GRJ45-XX-1GSFP-1GRJ45-XX-C1-F3.07
Description: 8 Port Gigabit Switch, (Power Supply) Input 36-72VDC, DIN Rail Mounting, 4 x 10/100/1000Base-TX RJ45 Ports, (Port 5) None,
1 x 100/1000Base-X SFP Ports, 1 x 10/100/1000Base-TX RJ45 Ports, (Port 8) None, Conformal Coating, Firmware version 3.07
C1 – Add for conformal coating
FW – Leave blank for latest firmware
NOTE: When selecting 1GSFP (Blank no optical transceiver**) **SFP’s to be ordered separately.
NOTE: When 6RJ45 option is selected Port 5 and 6 are not available.
All specifications are subject to change without notice | IS5 REV.12092015 www.iS5com.com | Page—5
**SFP’s to be ordered separately.
SFP Module # Description
SFP100-MM-2 SFP 100Mbps Multimode LC Transceiver 2km, 1310nm, -40°C - +85°C
SFP100-SM-30 SFP 100Mbps Singlemode LC Transceiver 30km, 1310nm, -40°C - +85°C
SFP100-SM-60 SFP 100Mbps Singlemode LC Transceiver 60km, 1310nm,-40°C - +85°C
SFP100-SM-100 SFP 100Mbps Singlemode LC Transceiver 100km, 1550nm,-40°C - +85°C
SFP100-SM-120 SFP 100Mbps Singlemode LC Transceiver 120km, 1550nm,-40°C - +85°C
SFP100BIDI1-SM-20 SFP 100Mbps Bi-Directional Singlemode LC Transceiver 20km, TX1310 nm, RX1550nm, -40°C - +85°C
SFP100BIDI2-SM-20 SFP 100Mbps Bi-Directional Singlemode LC Transceiver 20km, TX1550 nm, RX1310nm, -40°C - +85°C
SFP100BIDI1-SM-40 SFP 100Mbps Bi-Directional Singlemode LC Transceiver 40km, TX1310 nm, RX1550nm, -40°C - +85°C
SFP100BIDI2-SM-40 SFP 100Mbps Bi-Directional Singlemode LC Transceiver 40km, TX1550 nm, RX1310nm, -40°C - +85°C
SFP100BIDI1-SM-60 SFP 100Mbps Bi-Directional Singlemode LC Transceiver 60km, TX1310 nm, RX1550nm, -40°C - +85°C
SFP100BIDI2-SM-60 SFP 100Mbps Bi-Directional Singlemode LC Transceiver 60km, TX1550 nm, RX1310nm, -40°C - +85°C
SFP1000-MM-05 SFP 1000Mbps Multimode LC Transceiver 550m, 850nm, -40°C - +85°C
SFP1000-MM-2 SFP 1Gbps Multimode LC Transceiver 2km, 1310nm, -40°C - +85°C
SFP1000-SM-10 SFP 1Gbps Singlemode LC Transceiver 10km, 1310nm, -40°C - +85°C
SFP1000-SM-20 SFP 1Gbps Singlemode LC Transceiver 20km, 1310nm, -40°C - +85°C
SFP1000-SM-30 SFP 1Gbps Singlemode LC Transceiver 30km, 1310nm, -40°C - +85°C
SFP1000-SM-40 SFP 1Gbps Singlemode LC Transceiver 40km, 1310nm, -40°C - +85°C
SFP1000-SM-50 SFP 1Gbps Singlemode LC Transceiver 50km, 1550nm, -40°C - +85°C
SFP1000-SM-70 SFP 1Gbps Singlemode LC Transceiver 70km, 1550nm, -40°C - +85°C
SFP1000-SM-80 SFP 1Gbps Singlemode LC Transceiver 80km, 1550nm, -40°C - +85°C
SFP1000BIDI1-SM-10 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 10km, TX1310 nm, RX1550nm, -40°C - +85°C
SFP1000BID2-SM-10 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 10km, TX1550 nm, RX1310nm, -40°C - +85°C
SFP1000BIDI1-SM-20 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 20km, TX1310 nm, RX1550nm, -40°C - +85°C
SFP1000BID2-SM-20 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 20km, TX1550 nm, RX1310nm, -40°C - +85°C
SFP1000BIDI1-SM-40 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 40km, TX1310 nm, RX1550nm, -40°C - +85°C
SFP1000BID2-SM-40 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 40km, TX1550 nm, RX1310nm, -40°C - +85°C
SFP1000BIDI1-SM-60 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 60km, TX1310 nm, RX1550nm, -40°C - +85°C
SFP1000BID2-SM-60 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 60km, TX1550 nm, RX1310nm, -40°C - +85°C
SFP1000BIDI1-SM-80 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 80km, TX1310 nm, RX1550nm, -40°C - +85°C
SFP1000BID2-SM-80 SFP 1Gbps Bi-Directional Singlemode LC Transceiver 80km, TX1550 nm, RX1310nm, -40°C - +85°C
All specifications are subject to change without notice | IS5 REV.12092015 www.iS5com.com | Page—6