iDS6P www.iS5com.
com
Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE
Features
ââ Redundant Dual Ethernet Ports: Recovery time < 10ms
ââ Ethernet Switch Mode: Allows daisy chaining of multiple device servers
ââ NAT-pass through: User can manage iDS6P through NAT router
ââ Supports Dual Input Power Supplies
ââ Redundant multiple host devices: 5 simultaneous in Virtual COM, TCP
Server, TCP Client mode, UDP
ââ Secure Management by HTTPS and SSH
ââ Serial Server Modes: Virtual Com, Serial Tunnel, TCP Server,
TCP Client, UDP
ââ Event alarms via Syslog, Email, and SNMP trap
ââ iDS Manager software supports centralized management and
configurable by Web-based, Windows NT/2000/XP/2003/VISTA/7
ââ Ethernet switch mode allows daisy chaining
ââ Redundant facility to stream data to 5 host devices
ââ Event alarms by e-mail
ââ Secure management via HTTPS & SSH protocols
ââ NAT router pass through
ââ IP table security to prevent unauthorized access
ââ 2kV Port Isolation for RS-422/485
ââ 1kV Port Isolation for PoE Powered Device (PD) Port
Tel: +905-670-0004
iS5com.com
Fax: +289-401-5206
Email: info@is5com.com
#3-7490 Pacific Circle, Mississauga, Ontario, L5T 2A3
All specifications are subject to change without notice. IS5 REV.06172016 Page—1
Introduction
iDS6P is a serial device server with 4 isolated RS-422/485 serial ports to 2 redundant Ethernet LAN ports.
To ensure integrity and security of critical data, the iDS6P offers many powerful redundancy features. The
first feature provides protection against failure of an Ethernet LAN port, by automatically switching to another
LAN port within 10ms to guarantee delivery via an alternative path.
iDS6P also supports an Ethernet switch mode allowing users to daisy chain serial servers reducing the usage of
Ethernet switch ports. Another redundancy feature in the iDS6P is the simultaneous transfer of data of up to
5 host PC’s. This feature ensures that critical data is sent via alternative Ethernet paths and to multiple host
PC’s ensuring data is not compromised by the Ethernet connection or potential host PC failure. With NAT pass
through functionality, users are able to manage the iDS6P inside or outside the NAT router, making it easy for
different IP domain users to use the iDS6P. The secondary Ethernet port supports PoE IEEE 802.3af allowing
the device to be powered via the Ethernet cable instead of a separate power supply.
Configuration
The iDS Manager software utility can be used to configure the serial device server. This convenient utility
allows easy management and monitoring facilities of all servers on the network.
Redundancy 5 host devices NAT router Pass Through
All specifications are subject to change without notice | IS5 REV.06172016 www.iS5com.com | Page—2
Ethernet Switch mode
Windows Configuration Utility
All specifications are subject to change without notice | IS5 REV.06172016 www.iS5com.com | Page—3
Specifications
Model Number iDS6P
Physical Ports
10/100Base-T(X) RJ45 Ports
2
Auto MDI/MDIX
10/100 Base-T(X) PoE RJ45 Ports
1
w/ Isolation, Auto MDI/MDIX
RS-422/RS-485 Serial Ports in Pluggable
4
5 Pin terminal block
Serial Ports
Operation Mode RS-422 / 4(2)-Wire RS-485 - Can be configured by the Windows configuration utility
Serial Baud Rate 110 bps to 460.8 Kbps
Data Bits 5, 6, 7, 8
Parity odd, even, none, mark, space
Stop Bits 1, 1.5, 2
RS-422 Tx+,Tx-, Rx+, Rx-,GND
RS-485 (4-wire) Tx+,Tx-, Rx+, Rx-,GND
RS-485 (2-wire) Data+, Data-,GND
isolating 2KV
Flow Control XON/XOFF, RTS/CTS, DTR/DSR
LED Indicators
PWR 1(2) / Ready:
Red On: Power is on and booting up
Power indicator
Red Blinking: Indicates an IP conflict, or DHCP or BOOTP server did not respond properly
Green On: Power is on and functioning Normally. Green Blinking: Located by Administrator
10/100TX RJ45 port indicator Green for port Link/Act at 100Mbps. Amber for port Link/Act at 10Mbps
Serial TX / RX LEDs: Red: Serial port is receiving data, Green: Serial port is transmitting data
Power
Dual DC Inputs 10-48VDC, Single Input 36-72VDC with Single 10-48VDC Backup, or Single Input
Input Power
universal supply 88-370VDC or 85-264VAC with a Single 10-48VDC Backup
Power Consumption (Typ.) 5.5 Watts
Power Device (IEEE 802.3af): IEEE 802.3af compliant input interface, Power consumption: 8 Watts
Overload Current Protection max., Over load & short circuit protection, Isolation Voltage: 1000VDC min., Isolation Resistance : 108
ohms min
Reverse Polarity Protection Internal
Physical Characteristics
Enclosure IP-40 Galvanized Steel
Dimension (W x D x H) 101.8 (W) x 116.2 (D) x 154.1 (H) mm (4.01 x 4.57 x 6.07 inches)
Weight (g) ~2500 g
All specifications are subject to change without notice | IS5 REV.06172016 www.iS5com.com | Page—4
Environmental
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Operating Temperature -40°C to +85°C (-40°F to +185°F) No Fans
Operating Humidity 5% to 95% Non-condensing
Regulatory Approvals
EMI FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),
EMS
EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
Shock IEC60068-2-27
Free Fall IEC60068-2-32
Vibration IEC60068-2-6
Safety EN60950
Warranty
Warranty 5 Years
Dimensions
All Dimensions are in Inches
All specifications are subject to change without notice | IS5 REV.06172016 www.iS5com.com | Page—5
Ordering Information
Power Ethernet PoE Serial
Base Mount Description
Supply Port 1 Port 2 Port 3-6
iDS6P LV D 1RJ45 1PRJ45 4PL05
iDS6P | | | | | Core assembly and packaging
LV | | | | Dual Input (10-48VDC)
MV | | | | Single Input (36-72VDC) with Single 10-48VDC Backup
Single Input 88-370VDC or 85-264VAC with Single
HV | | | |
10-48VDC Backup
D | | | DIN Rail Mounting
P | | | Panel Mounting
N | | | No Mounting Hardware
1RJ45 | | 1 X 10/100Base-T(X) RJ45
1PRJ45 | 1 X 10/100Base-T(X) PoE with Isolation RJ45
4PL05 4 X Pluggable 5 Pin RS422/485
Example Order Code: iDS6P-LV-D-1RJ45-1PRJ45-4PL05-C1-F3.07
Description: 6 Port Device Server with PoE, (Power Supply) Dual Input (10-48VDC), DIN Rail Mounting, 1 x 10/100Base-T(X) RJ45 Port,
1 x 10/100Base-T(X) PoE with Isolation RJ45 Port, 4 x Pluggable 5 Pin RS422/485 Serial Ports,
Conformal Coating, Firmware version 3.07
C1 – Add for conformal coating
FW – Leave blank for latest firmware
All specifications are subject to change without notice | IS5 REV.06172016 www.iS5com.com | Page—6