Electronic Timers

On Delay • Release Delay • On Pulse • Symmetrical Recycler SXM

DESCRIPTION Release delay.


The timer must be connected to supply voltage permanently.
Multifunction timer with 5 functions and 4 time ranges. The function When the switch is closed, the output is energized. When the switch
and the time range are selectable via 2 front mounted rotary is opened again, the timing period starts.
switches. The output is de-energized when the preset time has elapsed.
Time ranges: 0.1-1sec, 1-10sec, 0.1-1min, 1-10min. The time is
Supply
adjustable on the timer front.
The timer can be supplied from a.c. mains(10/A2) or from 12-24V
On
AC/DC (11/A3) depending on the terminal used. Off
T T
Solid state output with triac (AC) or transistor (DC) with LED
LED
indication of energized output. Intermittent flashing of LED indicat-
ing timing period (over 6 sec.).The version with a.c. output includes
zero voltage switching. Supply and output are galvanically isolated. On pulse - without control switch.
Versions available for DIN rail or 11-pole plug-in mounting. A jumper must be connected between 5 and 7 (B1 and B2).
When supply voltage is connected, the output is energized and the
timing period starts. The output is de-energized when the preset
time has elapsed.

VERSIONS/ORDERING CODES Supply


On
Off
Type: SXM - S A 230 T T

On delay. LED

Release delay.
On pulse - without control switch. SXM On pulse - with control switch.
On pulse - with control switch. The timer must be connected to supply voltage permanently.
Symmetrical recycler with pause start. When the control switch is closed, the output is energized and the
timing period starts. When the preset time has elapsed, the output
Mounting: de-energizes.
11-pole plug-in. S To energize the output again, the control switch must be opened and
DIN rail. D closed again, after the output is de-energized.

Output: Supply

AC. (12-240V). A
DC (12-48V). D On
Off
T T

Supply voltage: LED

110/120V AC/12-24V AC/DC 115


220/240V AC/12-24V AC/DC 230 Symmetrical recycler with pause start.
When supply voltage is connected and the pause period has
elapsed, the output is energized. The output remains energized
during the pulse period. The sequence is repeated until the supply
voltage is disconnected.
OPERATION The duration of the pause and pulse periods is equal.

The function is selected via the rotary switch on the timer front. The
Supply
switch may only be operated, when the supply voltage is discon-
On
nected. Off
T T T T

On delay. LED

The timing period starts when the supply voltage is connected.


When the preset time has elapsed, the output is energized.
The output is de-energized when the supply voltage is discon-
nected.
Supply
On
Off
T T
LED
47.98

Export: United Kingdom: Germany:


Tel: +45 46 74 00 00 Tel: +44 020 8546 4283 Tel: +49 208 46954-0
Fax: +45 46 75 73 36 Fax: +44 020 8547 3628 Fax: +49 208 46954-50
E-mail: bc@brodersencontrols.com E-mail: bcs@brodersen.co.uk E-mail: ba@brodersen.de
14

sxm_00.p65 2 26-10-01, 14:29


Electronic Timers
On Delay • Release Delay • On Pulse • Symmetrical Recycler SXM

INTRO...
TECHNICAL DATA WIRING DIAGRAMS
Time ranges: 0.1-1sec, 1-10sec, 0.1-1min, 1-10min. Supply voltage above 50V.
Full linearity between the ranges is provided, i.e. an adjustment The installation (all terminals) must be carried out according to the
made to a specific time in seconds will give the same time in safety regulations! The control input and the supply input must be

XM
minutes just by operating the range switch. connected to the same circuit (phase and main switch). The output
may only be used in circuits made according to the safety regula-
Timer accuracy: tions.
Repeating accuracy: ± 0.5% at constant conditions.
Setting accuracy: ± 10%. Supply voltage below 50V.

XW
Temperature drift: Max. 0.15% per °C. The output may NOT be used for voltages above 50V unless the
entire supply circuit is made according to the safety regulations.
Start pulse: Min. 30msec.
On delay. Symmetrical recycler. On pulse
Reset time: Max. 100msec. (without control switch).

XMW
Input current A1 15 B1 B2
5
6
7
A1 15 B1 B2
5
6
7
(control switch): 3-5mA (max. 0.2A peak). 4 8 4 8
3 9 3 9
Output : 18 A3 A2
2 10
18 A3 A2
2 10

XT
1) on page 17 1 11 1 11
Load (cosϕ=1): DC: Max. 2A/60V (3A/60V peak). 115/230V 115/230V 115/230V 115/230V
AC: Max. 1A/240V (1.5A/240V peak).1) on page 17 Supply Supply Supply Supply
L N L N L N L N
Voltage: DC: 12-48V (10-60V).
AC: 12-240 V (10-265V).
Minimum current: DC: 0. See notes on page 17 See notes on page 17

XOT
AC: 5mA/cosϕ>0.25.
Voltage drop: DC: Max. 0.2V. Release delay. On pulse (with control switch).
AC: Max. 1.2V. Alternative 1 Alternative 2
Leakage current: DC: Max. 0.1mA.
AC: Max. 1mA.

SXM
Release time: Typ. 20msec. A1 15 B1 B2 6
5 7 A1 15 B1 B2 6
5 7
4 8
4 8
Mounting: 3 9
3 9
S: 11-pole plug-in. 2 10
18 A3 A2 2 10
D: Directly on DIN rail TS35 (EN50022). 1 11 18 A3 A2

SXT
1 11
115/230V 115/230V
Supply Supply 115/230V 115/230V
Supply Supply
Terminals: (D1 only) Max. conductor size 4 mm2. L N L N L N L N
Screw type terminals with self-lifting clamps shrouded in accord-
ance to VDE0106 (finger and back of hand protection). See notes on page 17 See notes on page 17

TXM
Supply voltage: 110/120V AC (95-135V) and 12-24V supply (all functions). AC output.
12-24V AC/DC (10-30V).
12-240V AC
220/240V AC (195-265V) and ~
A1 15 B1 B2 6
12-24V AC/DC (10-30V). 5 7 -DA -SA
6
4 8 A1 15 B1 B2
5 7

TXW
3 9 4 8
Mains frequency: 47-63Hz.
2 10 3 9
18 A3 A2 1 11
2 10
Consumption: 0.5-3VA. 18 A3 A2 1 11
+/ ~ -/ ~ +/ ~
-/ ~ Load
12-24V 12-24V max. 1A
Cable lengths: Supply Supply ~

TXT
Supply voltage:Max. 25 m.
Control switch: Max. 50 m. DC output.
Negative common Positive common
Protection:
S: IP40. 12-48V DC
+ 12-48V DC
XI
D: IP20. -DD -SD
A1 15 B1 B2
5
6
7
Load +
max. 2A
4 8 -DD -SD
EMC: Conforming to EN 50081-1/EN 50082-2. A1 15 B1 B2
5
6
7
3 9
4 8
2 10
Isolation: 18 A3 A2 1 11 3 9
XB

Supply to output: 2kV AC according to EN 60950 class I. Load


18 A3 A2
2 10
max. 2A 1 11
- -
1) on page 16
Ambient temperature:-20 to +55°C.
MECHANICAL DIMENSIONS, SXM & SXT
Housing: Black Noryl SE-1.
XWI

10 47 10 27
Weight: Approx. 80 g.
XIW
75
45

XIW
XF

13 53.5 6 53.5 6
47.98

Export: United Kingdom: Germany:


Tel: +45 46 74 00 00 Tel: +44 020 8546 4283 Tel: +49 208 46954-0
Fax: +45 46 75 73 36 Fax: +44 020 8547 3628 Fax: +49 208 46954-50
E-mail: bc@brodersencontrols.com E-mail: bcs@brodersen.co.uk E-mail: ba@brodersen.de
15

sxm_00.p65 3 26-10-01, 14:29

You might also like