The Diatron P700 is a fully automated clinical chemistry analyzer designed for high throughput, capable of performing up to 720 tests per hour with advanced features such as barcoded reagents and a multifunctional probe system. It offers a compact design with a variety of sample and reagent handling capabilities, ensuring efficient and cost-effective laboratory operations. The system includes over 50 CE-IVD marked reagents, providing a comprehensive range of validated tests for clinical chemistry applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views4 pages

P700 Brochure

The Diatron P700 is a fully automated clinical chemistry analyzer designed for high throughput, capable of performing up to 720 tests per hour with advanced features such as barcoded reagents and a multifunctional probe system. It offers a compact design with a variety of sample and reagent handling capabilities, ensuring efficient and cost-effective laboratory operations. The system includes over 50 CE-IVD marked reagents, providing a comprehensive range of validated tests for clinical chemistry applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Pictus 700

THE SMART CHOICE FOR


TODAY’S LABORATORY
ANALYZER
OVERVIEW
Diatron’s P700 is a fully automated, random P700 belongs to State Of The Arts family of
access, small footprint, floor standing chemistry clinical chemistry systems. Within the family the
analyzer. Innovatively designed with 2 reaction instruments share common, barcoded reagents
trays and robotic arms, the system can achieve menu, consumables, controls and calibrators. All
a total throughput of up to 720 tests/hour. The fully validated.

REAGENT TRAY
• 72 position removable reagent tray
• Onboard refrigerator
• Barcoded reagents

WASH SYSTEM
• 6 steps optimized washing system
• Automatic cuvette check prior to use
• Reusable cuvettes for low operating cost

SAMPLE TRAY
• 95 (5 x 19) position barcoded sample racks
• New design to accommodate a variety of
primary tubes and cups
• Uninterrupted workflow

MULTIFUNCTIONAL PROBES
• Clot, crash and liquid detection on both probes
• Pre-heated probe for faster test times
• Variable intensity mixer

DIATRON CLINICAL CHEMISTRY


REAGENTS
In combination with the analyzer we have over 50 reagents, calibrators and controls. Our tests
CE-IVD marked tests to offer a comprehensive include substrates, enzymes, electrolytes, lipids,
range of validated high quality Clinical Chemistry specific proteins and special tests.
SPECIFICATIONS
THROUGHPUT*: OPTICS:
• Up to 600 photometric tests/hour mono reagent • Light source: Precision UV quartz halogen lamp
• Up to 180-240 ISE tests/hour with optional ISE unit • Photometric Range: -0.1 to 3.6 A
• Maximum combined throughput up to 720tests/hour • Measuring wavelength: 340, 380, 405, 450, 490,
ANALYSIS MODES: 505, 550, 590, 620, 650, 700, 750 nm
• Full and optimized Random access • Photometry: Single or Double-wavelength
• Sample or batch mode simultaneous reading
• Real STAT REAGENTS:
• Continuous reagents and samples loading • Reagent cooling compartment: 72 cooled
• Test profiles definition positions 8+/- 2oC
• Automatic sample pre and post dilution • 1 to 3 reagents, 5 to 480 μL in one step
(1:2 to 1:120) (in increments of 1 μL)
• Automatic sample re-run • Min. reaction volume 180ul
• Reflex testing • Max. reaction volume 650ul
METHOD TYPES: • Reagent bottles size: 20, 40 and 70 mL
• 1point end point, 2point end point, fixed time, BCR:
kinetics, calculated • On-board samples and reagents barcode
• With or w/o sample and reagent blank.d recognition
CALIBRATION: PIPETTING ARMS:
• Automatic calibration. Automatic curve fit. Factor • Two pipetting arms for both sample and reagent,
or standard. Single and multipoint (unlimited) reaction pre-heater, probe collision sensor
• Calibration formulas: linear, multilinear, polynomial, • reaction mixer and clot detector
sigmoidea, Logit4, Logit5, spline • Probe cleaning: Internal and external washing
QUALITY CONTROL SYSTEM: OPTIONAL ISE UNIT:
• Levy-Jennings and Twin QC,Westgard multi-rules • Medica ISE module: Na+, K+, Cl- and optional Li+
SAMPLES: measurements
• Sample volume: 2 to 200 μL/test DATA MANAGEMENT:
(in increments of 1 ul) • Import/export database
• Sample Tray: 95 (5 racks x 19 positions) • Automatic backup procedure
• Primary tube (length up to 100 mm) • Windows TM based Software
• Paediatric vials INTERFACE LIS:
• 2 types of adaptors to accommodate variety of • Bi-directional RC 232 C, ASTM E 1381-95, ASTM
sample tubes and cups (ext. diameter 11.5-16mm) E 1394-97
PRINTOUT: ENVIRONMENTAL CONDITIONS
• Customer optimized (Analysis result, work list, list • Transportation and storage: -10 to 40 oC,
of samples, Quality Control, Calibration curves, etc.) humidity 30 to 90% noncondensing, pressure 600
WATER CONSUMPTION**: to 1050 hPa
• Typically ~5 L / hour • Use: 15 to 30 oC, humidity 40 to 80%
POWER REQUIREMENTS: noncondensing, pressure 600 to 1050 hPa
• 110/220V, 50/60 Hz, 1.4 kVA DIMENSIONS:
REACTION TRAY: • 97(w) x 67(D) x 100 (H) cm
• Reaction cuvette: re-usable plastic 6 mm light path WEIGHT:
• Reaction time: 0 to 25 min • ~175 Kg
• Reaction temperature: adjustable, default 37ºC ±
0.1ºC
• Stirring: After dispensing each reagent
• 6 steps washing station

*The throughput is measured by the time elapsed between receiving the first and the last result. It will vary depending on the ratio of 1 and 2 steps assays as well as number of ISE tests. The ISE
throughput depends on number of channels/electrodes used in the module.
**Water consumption: up to 6L/h depending on the number of extra programmed washes and number of batch runs
BENEFITS AND KEY FEATURES

EFFICIENCY EASY TO OPERATE AND LEARN


• 95 sample positions • Windows based operation system
• 72 single reagent positions • Flexibility for reagents application
• First results within 45 seconds • Sophisticated features for use and training
• Internal optional 4 channel ISE • Intuitive post dilution and result checking
• Optimized walk away operation • Graphically represented menus – easy to
COST EFFECTIVE AND use icons
OPTIMIZED WORKFLOW • Autocal and auto QC features
• Low water consumption (less than 5 l/h) RELIABLE HIGH QUALITY OPERATION
• Minimal consumable usage • ISE, dilutor, pumps from suppliers
• Real time reagent inventory control of proven technology
• Real stat sample capacity • Capacitative level sensor
• Clot detector
• Internal BCR for racks, samples and reagents

Analyzer and ISE module Liquid Consumables


Catalogue SAP No Cat. No. Product Name Pack
Description SAP No size
No
Additive for wash 2x250
10030697 VA0002SL
Pictus 700 Clinical solution ml
P700-1 10025301
chemistry analyzer
10025810 VA0003SL Calibration Set 4x50 ml
Pictus 700 Clinical 2x250
10030695 VA0000SL Cleaning solution
chemistry analyzer P700-3 10025302 ml
with ISE module

We are a member of the STRATEC Group I www.diatron.com I sales@diatron.com


The herein provided information and specifications by DIATRON are provided on an “as-is” basis and may be subject to changes, omissions
and errors. DIATRON shall have no liability for the accuracy and completeness of these information and specifications and cannot be held
liable for any representations or warranties, expressed or implied, and any third party claims or losses of any damages thereof.
DIATRON reserves the right to make any changes to the information and specifications at any time and without notice. The applications
and products herein may not be available in all markets I Nr. P700211105V9

You might also like